INTELLIGENT FLANGE STRÖTER. Magnetic pulse generator

Similar documents
FREQUENCY CONVERTER STRÖTER. Speed-Commander

Electric Mini Slides MSC-EL

VFD E Series. Features

Incremental encoders Solid shaft with clamping or synchro flange pulses per revolution programmable

VARICON. Three-phase AC motor with integrated frequency inverter

LIFT INVERTER SERIES L1000V DE ES FR IT 1000V L1000V L1000V L1000V L1000V

Paddle-wheel flow controller for On/Off control

VHS... Screw Flow Meter

SERIES PR90H PROGRAMMABLE INCREMENTAL HOLLOW SHAFT ENCODER FOR INDUSTRIAL APPLICATIONS REFERENCE PR90H - C C - C. External diameter 58 mm

ACME SCREW LINEAR ACTUATOR. OVERALL DIMENSIONS La =Lc + Stroke Lc T Capacitor

SINUS PENTA 2T/4T SINUS PENTA 2T/4T

IRT 4000 AT-S/M/L. Technical Manual. quality IN MOTION. quality IN MOTION

HBI 22. Integrated Three-phase Synchronous Drive

Paddle-wheel flow controller for On/Off control

More freedom - lower cost

Brake Chopper BC BC 4.1. Instruction and Operation Manual

sinamics SINAMICS G110 Variable Speed Drives 0.12 kw to 3 kw SINAMICS G110 Short Form 2004

Intelligent Drivesystems, Worldwide Services. ELECTRONIC DRIVE SYSTEMS UP TO 160 kw

J1000. Compact Inverter Series.

Unidrive M400 Fast set-up and diagnostics with real-text display, integrated PLC and safety inputs

Rotative measurement Incremental rotary encoder RI-10S10C-2B500-H1181

J1000 D E F I 1000 J1000 J1000 J1000 J1000

3242 G 024 BX4 CS/CC 24 3,6 18,2 77,3 1,6 / 12,4 9 / ball bearings, preloaded 0,015. stainless steel 370 electronically reversible

Unidrive M600 High performance drive for induction and sensorless permanent magnet motors

Rotative measurement Incremental rotary encoder Ri-10S10C-2B5000-H1181

Rotative measurement Incremental rotary encoder Ri-10S10C-2B1000-H1181

ecotrans Lf 01/02 Microprocessor Transmitter / Switching Device for Conductivity

Encoder WDG 58V.

Electronic Pressure Switches

GS2 Series - Introduction

SMS PRODUCT CATALOGUE

2232 S 024 BX4 CSD/CCD 24 12,4 6,4 67,7 2 / 17 4,1 / ball bearings, preloaded 0,015. stainless steel 77 electronically reversible

REGAL-BELOIT SpinMaster AC Adjustable Speed Drives

Lenze. Global Drive 9300 servo inverters kw

Power Electronics. MINISTOP Motor Brake Relay BA 9034N

High performance Vector Control. Ratings. System configuration

Temposonics. G-Series Analog Redundant. Magnetostrictive Position Sensors. Redundancy for enhanced safety

Positive displacement batch controller

How New Angular Positioning Sensor Technology Opens A Broad Range of New Applications. WhitePaper

Technical Data Sheets

Electronic Pressure Switches

Temposonics. E-Series Analog + Start / Stop. Magnetostrictive Position Sensors. Temposonics EP Measuring range mm / mm SENSORS

Demag KB conical-rotor brake motors. Drives with unique principle

Planning and Commissioning Guideline for NORD IE4 Synchronous Motors with NORD Frequency Inverters

Temposonics Magnetostrictive, Absolute, Non-contact Linear-Position Sensors

SMI SERIES MOTORS WITH INTEGRATED INVERTER

GEMÜ 539 esydrive Motorized globe valve

Online data sheet DFS60B-S4PC10000 DFS60 INCREMENTAL ENCODERS

Paddle-wheel flow controller with optical principle for On/Off control

GEMÜ 549 esydrive Motorized globe valve

Frequency inverters overview

SINAMICS G120. Inverter chassis units 0.37 kw to 90 kw Supplementary system components Basic Operator Panel BOP. Supplementary system components

MANTECH ELECTRONICS. Stepper Motors. Basics on Stepper Motors I. STEPPER MOTOR SYSTEMS OVERVIEW 2. STEPPING MOTORS

LINEAR ACTUATORS INDEX

Technical Data Sheets

Variable speed drive ALSPA MV1000. Power Conversion. General Drives

ABB Component Drives ACS150, 0.5 to 5 Hp

Product Overview. Rotary Encoders for Potentially Explosive Atmospheres (ATEX)

BALL SCREW LINEAR ACTUATOR OVERALL DIMENSIONS. MASS [Kg] STROKE T STROKE LENGTH STROKE LENGTH. standard brake CODE

URM-00 TRAINING MODULE FOR INDUSTRIAL ELECTRIC MOTORS FOR MAIN DRIVE AND CONTROL CIRCUITS EDUCATIONAL KIT TO STUDY MOTORS CONTROL AND PROTECTION

Technical Data Sheets

Open Drive Excellence in the control

SD700FR. Regenerative Active Front End VARIABLE SPEED DRIVES POWER ELECTRONICS / SD700 SERIES 4 QUADRANT. icool

Superstatic 749. Fluidic Oscillation Compact Heat Meter

HVAC Products. Introducing the SED2 Variable Frequency Drives

Index. Cable Brakemotor cable for decentralized MOVI SWITCH Catalog AC Motors DR , DT56, DR /EN 10/14

INVEOR "Smart connections." on five levels

ALTIVAR 58 AC Drives

SINAMICS G110 Inverter chassis units 0.12 kw to 3 kw

TECHNICAL DATA SHEET KVA UPS Systemss

JUMO ecotrans Lf 01/02

CENTROIDTM. AC Brushless Drive. Product Spec Sheet

Electronic Ballast EVG 2000-T

Sliding doors / fire doors

Low voltage AC drives

SINAMICS GM150 IGCT version

Unidrive M700 Class leading performance with onboard real-time Ethernet

Standard Drives A & D SD Application Note

C-SERIES S-SERIES. Metric Machine Screw Jacks EMA LINEAR ACTUATORS

POWER SUPPLIES. Control Transformers p8-1 Modular Power Supplies p8-2 Switching Power Supplies p8-3 Automatic Battery Chargers p PAGE

Quick guide. Plug-in fans GPPM with FC101_106 August 2014

2.3. Adjustable Frequency Drives. Contents. Standards and Certifications

Safety Sensor CSS 180 Product Information

better measurement Simply a question of

Online data sheet DFS60B-S4CA08192 DFS60 INCREMENTAL ENCODERS

COMBIVERT. Servo Systems Nm rpm ANTRIEBSTECHNIK

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work

Hydrovar and Packaged Hydrovar

Intelligent Drivesystems, Worldwide Services ELECTRONIC DRIVE SYSTEMS UP TO 200 HP

VSD Series II Variable Speed Micro Drives

Flow VA 500/ 520. Flow sensors for compressed air and gases incl. temperature measurement. Verbrauch.

Liquid cooled heavy duty converter

INSERTION flow sensor for continuous flow measurement

HIGH PERFORMANCE VECTOR CONTROL DRIVE

Description 1/8-7.5HP

Design and application

Online data sheet DFS60B-S4EL00800 DFS60 INCREMENTAL ENCODERS

ELA Electromechanical Linear Actuators

Flow measurement FlexFlow PF20H Hygienic flow sensor

Technical Data Sheets

Transcription:

INTELLIGENT FLANGE STRÖTER agnetic pulse generator

Incremental magnetic pulse generator addons to drive systems is now possible in an easy and economical way both in new and existing installations. The Task When adapting gear motor units to meet the specific needs of customers for use in areas such as conveying technology, STRÖTER has developed an intelligent intermediate flange which considerably simplifies the measurement of speed and sense of rotation as well as the connection with coordinating control systems. What was previously only possible with time-consuming assembly and This magnetic incremental rotary transmitter is designed as an intermediate flange which is simply installed between the motor and the machine flange. This makes the integration of incremental position encoders in drive systems much easier no matter whether you use it for speed measurement, for positioning control, dosage control or for synchronisation control. the engineers at Ströter Antriebstechnik GmbH frequently came across the same problem: the installation of incremental rotary transmitters which are used for determining the angle and direction of rotation requires mechanical modifications to the motor. In addition to this, the encoder was frequently positioned on exposed points which left it prone to damage. Speed Control signal 1. Compact design: depending on the size, only 7, 10 or 12 mm flange thicknesses are needed for installation. 2. Simple installation: the flange and sensors are directly fastened to the motor and the magnetic ring is placed directly on the motorshaft. 3. Suitable for all IEC flange motors with sizes between 56 and 180. 4. Also suitable for other flange connections such as d.c. motors, hydraulic/compressed air motors, pumps etc. 5. No mechanical modifications required for assembly. 6. Tried and tested measurement principle: two Hall-sensors receive the signals for speed and direction of rotation. This allows precise measurements without wear and tear or maintenance requirements. 7. Installation: Between the motor and the machine flange; this provides mechanical protection, sealed between the motor and machine flange; protection type IP 67 8. Universal HTL Signal for all standard evaluations (PNP, NPN, RS 422). 9. Cost effective solution which is also suitable for the economic retro-fitting of drives. 10. Short-circuit proof, polarized and overvoltage protected transmitter electronics, in SD technology; fully integrated into the flange. 11. The monitoring system can be positioned up to 1000 m away from the transmitter. 12. The pulse number can be doubled or quadruplicated by means of subsequent electronic systems. Positioning Control Position 1-8 Digital Synchronisation Control Torque Control Dosage Control n [%] 200 Parameter Input : quantity signal aster Slave control 100 80 60 40 20 Slip External starting command signal 10 50 [Hz] Dosage pump

otor-flange dimensions ta e øa øb ødi øb ød ø Da min k STAR-Tolerancering S f1 c f2 a b c di e f1 f2 k s 80 50 10 42 65 2,5 3 10 6 90 60 7 52 75 2,5 3 7 7 105 70 7 62 85 2,5 3 7 7 120 80 7 70 100 3 3,5 7 7 140 95 7 85 115 3 3,5 7 9 10 85 115 3 3,5 10 9 160 110 7 100 130 3,5 4 7 9 10 100 130 3,5 4 10 9 200 130 10 120 165 3,5 4 10 11 250 180 12 170 215 4 5 12 13 300 230 12 220 265 4 5 12 13 350 250 12 240 300 5 6 12 17 BG d x Lengtha ta Da 56 Ø 9 x 20 1 22 63 Ø 11 x 23 2 52 56 Ø 9 x 20 2 63 71 Ø 14 x 30 2 63 56 Ø 9 x 20 2 63 63 Ø 11 x 23 2 63 80 Ø 19 x 40 2 63 63 Ø 11 x 23 2 85 71 Ø 14 x 30 2 85 90 Ø 24 x 50 2 85 71 Ø 14 x 30 2 90 80 Ø 19 x 40 2 90 90 Ø 24 x 50 2 90 100/112 Ø 28 x 60 2 90 80 Ø 19 x 40 2 90 90 Ø 24 x 50 2 90 100/112 Ø 28 x 60 2 90 100/112 Ø 28 x 60 2 90 132 Ø 38 x 80 2 120 160 Ø 42 x 110 2 120 180 Ø 48 x 110 2 120 Flange Shaft Ø 80 Ø 9 Ø 90 Ø 11 Ø 105 Ø 9 Ø 14 Ø 120 Ø 9 Ø 11 Ø 19 Ø 140 Ø 11 Ø 14 Ø 24 Ø 160 Ø 14 Ø 19 Ø 24 Ø 28 Ø 200 Ø 19 Ø 24 Ø 28 Ø 250 Ø 28 Ø 300 Ø 38 Ø 350 Ø 42 Ø 48 Deliverable Pulse Numbers 1 1 2 4 5 6 8 9 10 11 15 16 20 25 30 40 2 50 100 2 200 3 X X X X X X X 2 X X X X X X X 2 X X X X X X X X X X 2 X X X X X X X X X X 2 X X X X X X X 4 X X 4 X 4 X X 4 X 4 X X 2 X 4 X 4 X X X X X X X 4 X X 4 X 4 X X 4 X 4 X X 2 X 4 X 4 X X X X X X X 4 X X 4 X 4 X X 4 X 4 X X 2 X 4 X 4 X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X 1 extra on request 2+3+4 Additional Cost 4 Flange 10 mm wide ass c u. k = 10 Order Example: I G 1 0 5 1 4 2 0 Flange Diameter Shaft Diameter Pulse Number

Special designs available upon request 1. Standard Design 2. Cover Design 3. Design with base Type:...-...-... Type: D...-...-... Type: B...-...-... e.g. flange motor e.g. conventional motor e.g. otor without fan Design with plug-in connection 4 pin plug (NOT for TTL design) View of motor shaft (cable connection left) otor Type B5 and B14 otor Type B3/B5 or B3/B14 otor with flange on fan side Available cable length 5 m or 10 m Connection: Standard 2 m cable, 4 x 0.25 shielded, special lengths available on request. - Speed Adjustment Speed Control Dosage PI-Control Positioning Synchro control Torque control Tailor-made products The ideal supplement for all kinds of control systems General: The Speed- is a static frequency inverter with variable voltage-link for continuous speed adjustment in three-phase a.c. motors. Vector modulation and 16 bit microprocessor Display panel for: - otor frequency, motor current, intermediate circuit voltage - parameter values, error messages Galvanized, separate control inputs for: - frequency setpoints - Right-hand rotation - Left-hand rotation - STOP (controlled braking) - OFF (potential free motor clamps) - STOP/HALT (d.c. brake) Programmable relay and transistor output (NPN) Special U/f characteristic curve for fan and pump operation Performance range: - up to 1.5 kw - 1 x 230 VAC - 1.1 to 22 kw - 3 x 400 VAC Integrated software for: - PI Control (pressure, temperature etc.) - Dosage control - Digital synchronisation - Torque control - Gate control Serial communication with PC or programmable controller special software with PLC-functions according to customers requirements Characteristics: Future-safe, flexible software design for control boards Easy operation due to menue-assisted digital parameter setting High starting torque Low-noise motor operation as a result of high pulse frequency IxR-Compensation (Boost) Programmable voltage/frequency ratio d.c. braking with static torque Potential free, PLC-compatible control inputs Protection against over/under-voltage, excessive current, short circuits on output or to earth, overheating (inverter and motor) Optimum design with small installation space requirements ultiple motor operation possible Options: - RS232/RS485 serial interface - Brake-chopper and braking resistor - External display etc. Vector odulation: Sinusoidal motor current Loop for magnetic flux Optimum motor magnetization at all speeds and loads IGBT s as circuit breaker for low-loss operation

-PULSE GENERATOR Incremental magnetic pulse generator type echanical Data max. speed Temperature Range: Electronics Flange/Hub materials 6,000 RP - 40 C to 100 C at Iloads 20 ma (120 C at Iloads 15 ma) Cable - 40 C bis 80 C Aluminium / Steel Connection Cable PUR sheath / 4 x 0.25/ Ø 5 mm (TTL 6 x 0.14) Cable Length/Plug Standard 2 m or other lengths on request Design with plug-in connection 4 pin plug / length of cable 5 m or 10 m (NOT for TTL design) Protection depending on the sealing between motor and machine flange (max. IP 67 e.g. where sealed with silicon) Permissible Vibration 100 m/s 2 Permissible Shock 1000 m/s 2 Electrical Data Standard TTL-Design Voltage Supply 10 to 24 VDC / + 20% 5 VDC / ± 5% max. pulse frequency 20 khz 20 khz Output Signals Square-wave pulses (two-channel) A + B Square-wave pulses (two-channel) A + B und A +B inv. Pulse sequence A 90 B tolerance ± 40 el A 90 B tolerance ± 40 el A 90 B inv. tolerance ± 40 el ark-to-space ratio 180 : 180 tolerance ± 20 el 180 : 180 tolerance ± 20 el Signal Level Uhigh - 4 V at Iloads 10 ma Uhigh 3,5 V Ulow 1 V Ulow 0,3 V Output Loading 30 ma at = 10 V bzw. max. 30 ma Capability 20 ma at = 24 V Insulation resistance 100 Ω 100 Ω Insulation testing 4 kv 4 kv Short-circuit-proof yes no Polarized yes no Tests EC-Test in accordance with EN 50081-1 (Emission) and EN 50082-2 (Immunity) Output Signals For determining the direction of rotation, the two rectangular pulse signals A and B are offset by 90. ark-to-space ratio 1:1 Signal evaluations Circuit: PNP NPN Cable length: 100 m 100 m A.B A.B 10-30 V Rl 1K 100R 1K Signal Signal evaluations Circuit: RS 422 Cable length: 1000 m Electronicevaluation Electronicevaluation A B A.B z.b. 26LSB2 5V Signal 10-30 V Rl Signal Electronicevaluation

Our range... adjustable variable speed drives range of adjustment 1:10 conveyor drives energy-saving drives Service around the world... geared motors from 0.09 to 22 kw frequency inverters...and software: positioning, proportioning, synchro control door controls, torque limiting systems bevel-geared motors from 0.09-22 kw bevel-geared variable speed drives range of adjustment: 1:10 incremental magnetic pulse generator...for flanges and special structural shapes worm gears dc motors 3-phase motors systems for power monitoring, positioning, pi-controllers Ströter Antriebstechnik GmbH 1/00 Design may be subject to change. STRÖTER D-40549 Düsseldorf Krefelder Straße 117 Telefon (0211) 9 56 00-0 Telefax (0211) 50 4415 E-ail: info@stroeter.com Internet: www.stroeter.com