HQUA. UV Water Sterilizer Instruction Manual. Contents

Similar documents
Laboratory Series. Ultraviolet Ozone Destruct System Installation, Operation and Maintenance Manual. One Source for All Your UV Needs!

OWNER'S MANUAL PURIFY WATER 99.99% FREE OF BACTERIA AND VIRUSES! Model IHS12-D4 and IHS12-D4/2 WHOLE HOME UV DISINFECTION SYSTEM

Owner s Manual. PUV-Basic PUV-8 PUV-16. (NSF Standard 55 Class B Certified)

Owner s Manual. Models: VT1, VT1/2, VT1/2A, VT1/2B, VT1/12 VT4, VT4/2, VT4/2A, VT4/2B, VT4/12. Powered by _RevP

gamma uv Aquarium Ultraviolet Sterilizers

Owner s Manual. Powered by. Models: VH200-F10, VH410-F R_RevG

SUPER PUMP OUT SYSTEM

SUNC1200 / ITEM #40882 SUBMERSIBLE UTILITY PUMP OPERATIONS MANUAL

SUBMERSIBLE SUMP PUMPS

SUBMERSIBLE SUMP PUMPS

QUICK START GUIDE OWNER S MANUAL AL50 SERIES SAND FILTRATION TECHNOLOGY PLEASE CALL DO NOT RETURN TO STORE

SUNC3000 / Item #40885

Installation Power Management Unit Battery Cables and Battery Harness

PEDESTAL SUMP PUMP. MODEL # Español p. 11. Zoeller is a registered trademark of Zoeller Co. All Rights Reserved.

Ultraviolet Sterilization System Installation Instructions & Owner s Manual

OWNER S MANUAL SUBMERSIBLE UTILITY PUMP

For safety and to ensure proper use carefully read the contents of this manual before operating or installing the unit.

Submersible Pond Pump with UV 800 Gallons Per Hour

READ AND SAVE THESE INSTRUCTIONS. ComfortBreeze UV360-1 SYSTEM 24V Ultra-Violet Air Cleaner. Trion

Scale Feeder Manifold Water Filtration System Instruction Manual

Dual/Triple Manifold Water Filtration Systems Instruction Manual

OWNER S MANUAL SELF-PRIMING PORTABLE UTILITY PUMP

Pressure Roller with 24-inch Fixed Extension - For application of architectural paints and coatings -

Dual Flow Manifold Systems Instruction Manual

21", 33", 45", & 61" Installation & Operation Manual

SEWAGE PUMP MODEL # Zoeller is a registered trademark of Zoeller Co. All Rights Reserved. Español p. 14

GRINDER PUMP MODEL # Zoeller is a registered trademark of Zoeller Co. All Rights Reserved. Español p. 13

Full Flow Drinking Water System Model: 3MFF100

PRE-PLUMBED SEWAGE SYSTEM

HARDWARE KIT INSTALLATION GLOVES

ULTRAVIOLET WATER DISINFECTION SYSTEM OPERATION & MAINTENANCE MANUAL

US Water ORP Booster Injection System

HALLMARK INDUSTRIES INC

STOP CITY PRESSURE BOOSTER PUMP INSTRUCTION MANUAL

Installation & Maintenance of the Fresh-Aire UV Airborne Duct System for Commercial HVAC Systems. Parts Included. Optional Parts

For safety and to ensure proper use carefully read the contents of this manual before operating or installing the unit.

Installer s Manual. PCO/UV N-Duct Model

Gauge Adapter Instruction Manual

Owner s Manual WARNING

EBG Series Surface Preparation Machines

Audi R8. Ride-on Car 5F62630 OWNER S MANUAL. Keep instructions for future reference

Owner s Guide. Dumbwaiter. Series DUMBWAITER OWNER S GUIDE 1

GARDEN HOSE UTILITY PUMP

BIO-FIGHTER 4Xtreme 21", 33", 45" Ultraviolet Light Systems

Dual Port Manifold Water Filtration Systems Instruction Manual

ProFlo FatBoy

UV-AIRE AIR PURIFYING SYSTEM

DFA Series. Rainwater/Graywater Filtration Systems. Installation, Operation and Maintenance Manual DFM-2F-180 DFM-3F-180 DFM-3F-350

TRUSS KITS FOR SPOUTING Installation Manual

Specifications. Important Safety Information

INSTALLATION INSTRUCTIONS

Safety, Installation and Service Manual Models 1952, 1953 & 1972

MINISTICK TM UV Germicidal Ultraviolet Light

ESE Series Cast Iron Sewage Pumps

Owner s Manual GLASSLINED PUMP TANK

Manifold w/ Needle Valve Instruction Manual

AUTOMATIC SUBMERSIBLE UTILITY PUMP

INSTALLATION INSTRUCTION & OWNER S MANUAL

READ THIS MANUAL CAREFULLY BEFORE USING THE PUMP

DIRECT-DRIVE PRESSURE WASHERS

WARNING: FAILURE TO FOLLOW THESE RULES MAY RESULT IN SERIOUS PERSONAL INJURY CAUTION: INSTALLATION LOCATION:

Installation Manual DIAPHRAGM WELL TANK

US Water ph Booster-Reducer Injection System

Pro Shot Grease Dispense Valve

APCO ASR-400/450 SEWAGE AIR RELEASE VALVES

G E N E S I S S T O R M SPECIALIZED TOP OFF AND REPLENISHMENT MODULE

RipTide. Brewing Pump. Assembly, Operation, & Maintenance

Clevis Plunger & Base Instruction Manual

(L 70 ) 3000K / 4000K / 5000K 12 50,000 50, K / 4000K / 5000K 15 50, K / 4000K / 5000K 18 50,000

4-VOLT LITHIUM-ION AUTO-LOAD SCREWDRIVER w/led WORKLIGHT

Easy/Tran TF STANDBY POWER FURNACE SWITCH TOOLS NEEDED FOR INSTALLATION. PARTS LIST for Easy / Tran TF FURNACE TRANSFER SWITCH

SUBMERSIBLE MINI-PUMP

18 GAUGE FLOORING STAPLER. Models: /13

DWS404 DWS524 DWS654 DWS684 DWS694. DWS SERIES INSTALLATION/OWNER'S MANUAL Car Audio Speakers

LIGHTSTICK / LIGHTSTICK PLUS Germicidal Ultraviolet Light

PUMP SPY INSTALLATION AND OPERATING INSTRUCTIONS

Illumifalls Patio Pond

MaxLite LED Linear HighBay Fixtures

Advanced PCO System. Installation Instructions & Consumer Information. Section I. Important Installer Information WARNINGS

Flow Control Valve Instruction Manual

AQUA2000 ADVANCED WATER TREATMENT SYSTEMS OWNER S MANUAL INCLUDES: Restrictions. Installation. Operation. Maintenance. Changing the Filter

Heated Bakery Merchandiser Series. Series: WBC Operation Manual

A+ Battery Backup Power Supply For use with Hydromatic model B-A1/BV-A1

Owner s Manual & Safety Instructions

OPERATING MANUAL 18V Ni-Cd Battery Pack

Operator's Manual. Storage System. Ultrasound Probe Cabinet. Manufactured by:

Swing Arm Magnifying Lamp

SUBMERSIBLE PUMP. Model ASSEMBLY AND OPERATING INSTRUCTIONS

OWNER/OPERATOR MANUAL. Airmotor effective dia. in. 2.5

AEROMOTIVE Part # Ford 5.4L Shelby GT500 Mustang INSTALLATION INSTRUCTIONS

Submersible Waterfall Pump 1200 Gallons Per Hour

Owner s Manual. Installation, Operation & Maintenance Read and Follow All Safety Instructions. Save These Instructions. Ballast 230v 50/60Hz

STOP. Oil Pump Models L 5016, L 5116 & L Owner s Manual DO NOT RETURN THIS PRODUCT TO THE STORE! SAVE THESE INSTRUCTIONS TABLE OF CONTENTS

Oil Pump Models L 5016, L 5116 & L 5132

LED Convertible Dual Fixture Work Light on Tripod Stand

Kompensator External Low Voltage Heating Cable System

Lubricator Gun: 10,000 psi (700 bar) Maximum Delivery Pressure when disconnected from Dispenser

M-3025CB-AV Fuel Pump

FP0S2300X FP0S3000X. Submersible Waterfall/Utility Pumps OWNER S MANUAL. Call Installation/Operation/Parts. English...

1. Contents 1. CONTENTS INTRODUCTION SAFETY WARNINGS POWER TILT STANDARD OPERATING INSTRUCTIONS... 5.

Transcription:

UV Water Sterilizer Instruction Manual Contents Section 1 Safety Information 2-3 Section 2 General Information.4-7 Section 3 Maintenance.7-9 Section 4 Troubleshooting.10 Section 5 After-Sales Service...10 Commitment 11 Version No.20170601 By James Technical Support Team At TX,US 1

Section 1 Safety Information Safety Information Before you start doing the installation job, it s very important to read the entire content below. Make sure you understand these, to prevent the potential hazards. Failure to do so could result in serious personal injury or damage to the equipment. 1.1 Warning Labels To avoid potential hazards, read the labels and tags below carefully. These will occur in the installation parts of this manual as well. Waste electrical and electronic equipment (WEEE). This symbol indicates that you should not discard wasted electrical or electronic equipment (WEEE) in the trash. For proper disposal, contact your local recycling/reuse or hazardous waste center. The UV lamp contains mercury. If the lamp breaks, then avoid inhalation or ingestion of the debris and avoid exposure to eyes and skin. This symbol indicates there is a potential UV hazard. Proper protection must be worn. This symbol indicates the marked item could be hot and should not be touched without care. This is the safety alert symbol. Obey all safety messages that follow this symbol to avoid potential injury. When on the equipment, refer to the Operational and Maintenance manual for additional safety information. This symbol indicates safety glasses with side protection is required for protection against UV exposure. This symbol indicates a risk of electrical shock and/or electrocution exists. This symbol indicates gloves must be worn. This symbol indicates that the contents of the transport This symbol indicates the system is under pressure. package are fragile and the package should be handled with care. 1.2 Safety precautions. Electrical Safety Regardless of these instructions will result in serious injury or death. Electric Shock: To avoid possible electric shock, special care should be taken since water is present near the electrical equipment. Unless a situation is encountered that is explicitly addressed by the provided maintenance and troubleshooting sections, do not attempt repairs yourself.find a professional plumber or contact us for more help. Grounding Plug: This product must be grounded to reduce the risk of electrical shock. This system is equipped with a grounding plug. The plug must be plugged into an appropriate outlet that is properly installed and grounded in accordance with all local codes and ordinances. And do not use any type of adapter with this system. DO NOT operate the UV water sterilizer if it has a damaged cord or plug. DO NOT install this UV water sterilizer where it will be exposed to outdoor or under temperatures below freezing. 2

Safety Information DO NOT store this disinfection system where it will be exposed to the weather or under temperatures below freezing unless all water has been drained from it and the water supply has been shutted down. Physical Body Potential Hazards Hot Water Output Warning: The water in the chamber of this equipment can be very hot(approx. 140 F),during an extended periods of no water flowing. It is recommended to open the faucet until the hot water has been purged from your chamber. Keep your body away from the faucet during this time. To eliminate this condition, a temperature management valve can be installed at the outlet of your UV system. Ultraviolet Exposure Warning: This system contains an UV Lamp. Do not light up the UV Lamp when it is removed from the chamber. Unintended use or damage of the system may result in the exposure of dangerous UV radiation. UV radiation may, even in little doses, cause harm to the eyes and skin. It s dangerous to expose yourself directly under a lighted UV Lamp. Other Cautions Short Circuit Caution: Carefully examine the disinfection system after installation. It should not be plugged in if there is water on parts that shouldn t be wet such as, the ballast or lamp connector. Material Degradation Caution: Due to thermal expansion concerns and potential material degradation due to UV exposure, it is recommended to use metal fittings and at least 10" of copper pipe on the outlet of your UV chamber. Hg Exposure: The UV lamp contains mercury. If the lamp breaks, then avoid inhalation or ingestion of the debris and avoid exposure to eyes and skin. Never use a vacuum cleaner to clean up a broken lamp as this may scatter the spilled mercury. Obey local regulations and guidelines for the removal and disposal of mercury waste. Operation Caution: The UV system is not to be used or played with by children. Persons with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, are also not to handle the UV system unless they have been given supervision or instruction. Maintenance: The UV lamp inside the disinfection system is rated at an effective life of approximately 9000 hours. To ensure continuous protection, replace the UV lamp annually. This system is intended to be permanently connected to the water lines. This system is not intended to be used in or above water or outdoors or used in swimming pools. Extension Cords: If an extension cord is necessary, use only 3-wire extension cords that have 3-prong grounding-type plugs and 3-pole cordconnectors that accept the plug from this system. Read and understand the Owner s Manual before operating and performing any maintenance on this equipment. 3

Section 2 General Information General Information This Section includes the description of UV water sterilizer components and a brief installation. 2.1 Package List&Description According the list below to check the package. Make sure you get everything you need before installing.if something miss,contact the manufacturer and seller or its service agent to get more help please. 1.One Stainless Steel Chamber(304,food grade),37.2*2.5inch Cylinder with 3/4 in/outlet. 2.One Quartz Sleeve protect the UV lamp,37*0.85inch with one end. 3.Two UV lamps with 4pin one end,36.4inch*0.6inch(t5). 4.Two waterproof O-ring suit for the Quartz Sleeve. 5.Two plastic bracket. 6.One 55W Ballast-Power Supply with Standard US. 3-pin plugs. 4

2.2 Installation UV Water Sterilizer General Information Follow the installation steps one by one, make sure you understand each step before you move on it. Contact the manufacturer and seller or its service agent if you misunderstand the steps in this section. Prerequisites: Measure your water pipe system,make sure you have enough space for this product.mark the mounting position and drill two holes on the wall. Screw on the plastic bracket for later use. Make sure you have an adequate clearance above chamber to allow for removal of the lamp and sleeve. Make sure you have turned off the main water supply already. Pay attention to the labels appear in the installation procedures. Carefully operate please. Do Not Connect The UV Water Sterilizer To Electric Supply Before Your Finish The Installation. Procedures: 5

General Information 6

General Information Section 3 Maintenance Prerequisites: Always Disconnect power supply before performing any work on UV water sterilizer. Always shut-off water flow and release water pressure before servicing. Regularly inspect power indicators on the ballast :the green one represent the ballast and red one represent the UV lamp. Both on means our product is working on a good condition.if the green one is off and the red one is on,it s still working!but we suggest you check the UV lamp situation with protection of your eyes and skin. Replace the UV lamp annually (or biennially if seasonal home use) to ensure maximum disinfection. 3.1 Replace the UV lamp Replcing an UV lamp is quite easy and take a little time with it.one UV lamp s lifetime is nearby 9000 hours, so it should be replaced annually to keep its enough disinfection for 12GPM water flow. Procedures: 7

General Information Debugging Connect the power supply firstly, and check the indicator light to see if UV water sterilizer is working well.wait for 10-15 minutes to re-use faculets. 3.2 Clean&Replace the Quartz Sleeve The coating on the quartz sleeve will slowly form due to the minerals in the water. This coating must be removed because it reduces the amount of UV light reaching the water, thereby reducing disinfection performance. If the sleeve can not be cleaned, it must be replaced. Prerequisites: Close the water supply of your system and drains all lines. Make sure the water in the chamber lower than the quartz sleeve. Depressurize the unit. Place a small pail under the unit to catch any spills. Remove the UV lamp; Refer to Section 3.1 8

Procedures: General Information 9

Section 4 Troubleshooting Troubleshooting Symptom Possible Cause Solution GFCI and/or breaker tripped Reset GFCI and/or breaker Green Light Off Ballast damaged Replace ballast and use a TVSS Red Light Off Connection problem UV lamp damaged or died Power off&wait 15 minutes,adjust the connection between UV lamp and the ballast.then try it again Replace it with a new one Leak at inlet or outlet Threaded pipe fittings are leaking Clean threads, reseal with Teflon tape and retighten System is operating but water tests reveal bacterial contamination Equipment downstream of UV system is acting as a breeding ground for pathogens Recontamination from pipe dead-ends Ensure UV is the last piece of treatment equipment Remove any pipe dead-ends and flush with chlorine Section 5 After-Sales Service Should you need any support, or have questions about your system, please contact our Technical Support team at hqua_qin@163.com and we will be happy to assist you. We sincerely hope you enjoy the benefits of clean, safe drinking water after the installation of your disinfection system. 10

Our Commitment Commitment Specific Warranty Coverage Ten-Year Limited Warranty for UV Chamber warrants the UV chamber on the product to be free from defects in material and workmanship for a period of ten (10) years from the date of purchase. During this time, will repair or replace, at its option, any defective UV chamber. Please return the defective part to your dealer who will process your claim. One-Year Limited Warranty for Electronic Ballast warrants the Electronic Ballast to be free from defects in material and workmanship for a period of 1 year from the date of purchase. During this time, will repair or replace, at its option, any defective parts covered by the warranty. Please return the defective part to your dealer who will process your claim. Six-Months Limited Warranty for Lamps. warrants lamps to be free from defects in material and workmanship for a period of 6-months from the date of purchase. During this time, VIQUA will repair or replace, at its option, any defective parts covered by the warranty.please return the defective part to your dealer who will process your claim. General Conditions and Limitations None of the above warranties cover damage caused by improper use or maintenance, accidents, acts of God or minor scratches or imperfections that do not materially impair the operation of the product. The warranties also do not cover products that are not installed as outlined in the applicable Owner s Manual.Parts repaired or replaced under these warranties will be covered under warranty up to the end of the warranty period applicable to the original part. The above warranties do not include the cost of shipping and handling of returned items. The limited warranties described above are the only warranties applicable to the range of products. These limited warranties outline the exclusive remedy for all claims based on a failure of or defect in any of these products, whether the claim is based on contract, tort (including negligence), strict liability or otherwise. These warranties are in lieu of all other warranties whether written, oral, implied or statutory. Without limitation, no warranty of merchantability or of fitness for a particular purpose shall apply to any of these products. does not assume any liability for personal injury or property damage caused by the use or misuse of any of the above products. shall not in any event be liable for special, incidental, indirect or consequential damages. s liability shall, in all instances, be limited to repair or replacement of the defective product or part and this liability will terminate upon expiration of the applicable warranty period. 11

End 12