Installation Instructions: Memory-Dimmable SEP T8 Tube Lamps

Similar documents
Installation Instructions: External-Driver SEP T8 LED Tube Lamp

Installation Instructions: Eco-Fit T8 LED Tube Lamp

Installation Instructions: Eco Linear High Bay

Installation Instructions: Eco SpunBay LED High Bays

Instruction/Installation Manual

LED 2/3/4ft T8 Tube 120V

Product Installation Instruction LED Tube Lamp Retrofit Kits

LUNERA T8 LED RETROFIT KITS 1/2/3/4-Lamp Replacement Kits for 2FT or 4FT T8 Fluorescent Lamps

TECTONIC LED CORP. ISO


LED Recessed Troffer Retrofit Kit

READ AND FOLLOW ALL SAFETY INSTRUCTIONS! SAVE THESE INSTRUCTIONS AND DELIVER TO OWNER AFTER INSTALLATION.

Universal Retrofit System Installation Instructions Revised:

Strip Fixture URS Light Bar Retrofit Installation Instructions Revised:

READ AND FOLLOW ALL SAFETY INSTRUCTIONS! SAVE THESE INSTRUCTIONS AND DELIVER TO OWNER AFTER INSTALLATION.

Installation Guide. WARNINGS Read all instructions and warnings before attempting installation

ULTRA PERFORMANCE LED TUBE INSTALLATION INSTRUCTIONS

OPTIMAX RADIANT FIELD RETROFIT INSTRUCTIONS

LUNERA T8 LED RETROFIT KITS 2/3/4-Lamp Replacement Kits for 2FT or 4FT T8 Fluorescent Lamps

STOP BEFORE YOU BEGIN READ THESE INSTRUCTIONS COMPLETELY AND CAREFULLY

ECO EXT (DIMMABLE)

LED IMPORTANT SAFETY INSTRUCTIONS

INSTALLATION INSTRUCTIONS

Installation Instructions BLTR and 2BLTR Relight Assembly

Asymmetrical Installation Instructions. Components: i2cove Asymmetrical LED Light Fixtures. 12 [305mm] [918mm] 48.

Optimax Pro Retrofit Instructions

Redbird LED Cardinal Stripit Kit Installation Instructions

TRUET5 EXT (DIMMABLE)

Solid State T8 tube is the smart alternative to a

INSTALLATION INSTRUCTIONS LED RETROFIT ASSEMBLY (LRA) Rev F

Anthony LED Lighting System Retrofit Installation Instructions For Models 101X and 101A

IMPORTANT SAFEGUARDS When using electrical equipment, basic safety precautions should always be followed including the following:

Assembly Instructions Retrofitting

Installation Instructions: ACCENT HIGH OUTPUT SYSTEM

3. Please ensure the electricity connections conform to the National Electrical Code and local regulations if applicable.

Lumination TM LED Luminaire LUR Series

(L 70 ) 3000K / 4000K / 5000K 12 50,000 50, K / 4000K / 5000K 15 50, K / 4000K / 5000K 18 50,000

MaxLite LED UTILITY WRAP FIXTURES

READ AND FOLLOW ALL SAFETY INSTRUCTIONS 1. DANGER RISK OF SHOCK DISCONNECT POWER BEFORE INSTALLATION

LED microwave sensor T8 tube light

INSTALLATION INSTRUCTIONS ModuSys LED Retrofit Kit 2x2, rev. D.02

KT-EMRG-1400-SL /B. 3. Please ensure the electricity connections conform to the National Electrical Code and local regulations if applicable.

Installation Instructions: HYPERION R-Lite SYSTEM

Installation Instructions: ACCENT SYSTEM

LED Utility Wrap Fixture

MAXLITE RKT LED Retrofit Kit

LUNERA VERTICAL E26 LED FLOODLIGHT LED Replacement for E26 Medium Base Floodlights Type B Ballast Bypassed

HBC-20 - LED HIGH BAY

LED T8 BP. GE Lighting. Tubular lamps DATA SHEET. Specification Features. Product information. Applications. IEC standards

INSTALLATION INSTRUCTIONS 120V DirectAC LED Engine Kit

ECO-T LED RECESSED TROFFER USER MANUAL

LED Flat Panel Installation Instructions For 1 x4, 2 x2, and 2 x4 LED Flat Panels (FP Series)

PIL0478 ISSUE 01/ 07/16

Concealite Life Safety Products Model: R4000 Series (120/277 VAC Powered R4000 Remote Fixtures) Save These Instructions

SAVE THESE INSTRUCTIONS

Stik Families GENERAL PURPOSE RETROFIT SIGN CONVERSION FOR USE ONLY IN ACCORDANCE WITH KIT INSTRUCTIONS

LED.Commercial 12W LED DD

Incentives for Energy Efficient Lighting (Effective August 8, 2015 through December 15, 2015 * )

MaxLite StaxMax LED Flood Lights

INSTALLATION INSTRUCTIONS

CFP-LED Contractor Select Flat Panel. Installation Instructions

BAL3000 BAL3000. Fluorescent Emergency Ballast Lumens. Specification Sheet. Emergency Ballast 1/19/2012. Project: Catalog#: Approved by:

S HINE V ENTURE L IGHTING S LED LAMPS. Quality retrofit LED lighting products from a leader in the lighting industry. Full range dimming

General Installation Instructions LED

INSTALLATION. **Microprocessor Status LED:

Customer service: or Upper mounting ring. Canopy

NOTE: The orientation of the mounting brackets are critical. (See Figure 4)

INSTRUCTIONS FOR OUTDOOR WALL LANTERN, MODEL LPT-1032

INSTALLATION INSTRUCTIONS

IP65 COOLEDGE TILE EXTERIOR R2 INSTALLATION MANUAL. Exterior TILE Jumper Cable. Exterior Cutout TILE. Cable Clamp. T-Cable.

Ivalo Finiré 3 LED Recessed Lighting Installation Instructions

SURE-LITES FBP140XLP Instruction Manual

E E VDC COOLEDGE TILE INTERIOR INSTALLATION INSTRUCTIONS. Caution: Observe precautions for handling electrostatic sensitive devices.

WARNING: FAILURE TO FOLLOW THESE RULES MAY RESULT IN SERIOUS PERSONAL INJURY CAUTION: INSTALLATION LOCATION:

INSTRUCTION MANUAL IMPORTANT SAFEGUARDS. When using electrical equipment, basic safety precautions should always be followed, including the following:

LED Linear Lamp. 2, 3, 4, 5 lamps. Performance Specifications. LED T8 and T12 lamps

6. Easy for maintenance & drivers replacement. Detachable in 1 minute. Part No. Power Luminous Input Voltage PF CRI Diffuser Certificate

T8 Tube Light. UL LISTED & cul LISTED & DLC LISTED. Germany Patent: Gebrauchsmusters / Nr

IMPORTANT SAFETY INSTRUCTIONS

NOVO LIGHTED MIRROR. Installation Instructions

NICHE-HV. Installation Manual WARNING: DO NOT LIFT FIXTURE BY CABLES.

General Installation Instructions LED

INSTRUCTION MANUAL SINKER. By HAY

INSTALLATION INSTRUCTIONS

LEDlescent TM T8 Ballast-Free Lamps

n Ilation instructions Load Center Transfer TMOperator

Ultra-Thin Recessed LED Light Installation Guide

MaxLite LED Linear HighBay Fixtures

USE AND CARE GUIDE 15 INCH WHITE ROUND FLAT PANEL FIXTURE WITH SELECTABLE COLOR TEMPERATURE

ILLUMINA BS100 INSTALLATION INSTRUCTIONS FLUORESCENT VAPOR TIGHT

Round or Square Type Non-IC Adjustable Housing with Toroidal Transformer for Flangeless Trims E3_L_-HANM_ 1.7

LM79 LM80 L70:5+ YEARS

READ AND FOLLOW ALL SAFETY INSTRUCTIONS! SAVE THESE INSTRUCTIONS AND DELIVER TO OWNER AFTER INSTALLATION

FLUORESCENT EMERGENCY BALLAST Lumens. When using this lighting device safety precautions should be followed at all times

UV8 & UV90 SERIES INSTALLATION INSTRUCTIONS

Motion and Light Sensor Kit LHBAS51

HPNLS-HO. Installation Manual

SubstiTUBE Value EM T8 (AUS Fighter Tube) ST8V-0.6M ST8V-1.2M ST8V-1.5M

TOPAZ 12 WALL PACK INSTALLATION & MAINTENANCE GUIDE (Part # LIT A)

MEDIA LED. Pendant Standard Mount Installation ou de montage WARNING:

Transcription:

Installation Instructions: Memory-Dimmable SEP T8 Tube Lamps Installation Notes & Precautions: Memory-Dimmable SEP T8 LED Tube Lamp Read all precautions, warnings, instructions contained in this document. These instructions can be used to install up to four lightweight, all-plastic Memory-Dimmable SEP T8 LED tube lamps into a properly wired luminaire/troffer. Before installing lamps, verify that luminaire tombstone spacing matches the pin-to-pin lamp length. Installation should be performed by a qualified electrician or installer. Operating input voltages: 20VAC to 277VAC only LED tube is powered from one end (SEP); the other end is NOT live and only serves to secure and mount the LED tube in the socket. Verify that the luminaire is properly set up for this style of LED Tube before inserting into luminaire (modify luminaire if necessary). WARNING: Do not use shunted lamp sockets when rewiring fixture for SEP LED tube lamps. Shunted lamp sockets are often found in fluorescent luminaires with Instant-Start ballasts. These ballasts are labeled Instant Start or I.S. or designated as IS on the ballast markings, for example F40T2/IS. For more information, contact your Revolution Lighting representative. Dimming range: 00% to 0% Operating temperature range: -4 ºF to 3 ºF This light source is not intended as an emergency exit fixture or light. A Retrofitted Luminaire label is included with your LED tube. This decal must be placed in a prominent location on the luminaire so that it is visible when replacing an LED tube. If the luminaire is already modified for LED tube use and has a label, the new label may be discarded. The LED tube fits into any G3 Medium Bi-Pin socket (T8/T0/T2). Lampholder sockets do not need to be replaced unless they are shunted, damaged, or missing. Lampholders must be separated internally for proper wiring of the LED tube. (Refer to installation diagrams.) The LED tube may be used in open or enclosed surface or recessed (Type-IC) luminaires and in damp locations. The LED tube is not for use in luminaires controlled by a dimmer.

Warnings: Cautions: WARNING Risk of fire or electric shock. Do not use this retrofit kit in luminaires employing shunted bi-pin lampholders. WARNING Risk of fire or electric shock. Do not alter, relocate, or remove wiring, lampholders, ballasts or any other electrical component. If necessary, contact a qualified electrician for assistance. WARNING To prevent wiring damage or abrasion, do not expose wiring to exposed edges of sheet metal or other sharp objects. WARNING Always disconnect power for your safety when performing the luminaire modification steps below! In some cases, it may be necessary to test the power feed with the power connected. Only connect the power when doing the testing, then disconnect the power from the luminaire when performing the steps below. WARNING Always follow local and regional NEMA Electrical codes. NEMA codes provide information on proper procedures, safety guidelines, proper tools, connection methods, and specifications on materials. WARNING Revolution Lighting Technologies, Inc. cannot and will not be liable for any modifications or results of modifications to electrical devices or luminaires. These instructions are provided as a reference. By using the included instructions, you are solely responsible for following all applicable electrical safety procedures, codes, methods, and materials. If you are unsure about any electrical modification or installation, please consult a licensed electrician or electrical contractor in your area. CAUTION Risk of Shock. Use in Dry or Damp Locations Only. CAUTION Do NOT install this LED tube into a fluorescent luminaire containing a ballast and/or starter. The ballast and/or starter must be removed prior to installation. CAUTION Do NOT make or alter any open holes in an enclosure of wiring or electrical components during kit installation. CAUTION Do NOT install tube lamps in lampholders while power is connected. This practice, known as hot-swapping, can damage the internal electronics of the tube lamp. Doing so will void any and all Revolution Lighting warranty protections that the product carries.

Contents: Carefully open the box and check contents. Contact Revolution Lighting if any items are missing. # LIGHTWEIGHT ALL-PLASTIC MEMORY- DIMMABLE SEP T8 LED TUBE LAMP(S) [SKU #: (as ordered)] LUMINAIRE POWER SOURCE SOCKET LABEL [SKU #: 300003] Lightweight, All-Plastic Memory-Dimmable SEP T8 LED Tube Lamp(s) with frosted lens. This decal must be placed at the base of the powered LED tube socket on the LED-modified luminaire so that it is visible when replacing an LED tube. The arrow should point in the direction of the powered socket (only one label per retrofitted luminaire required at powered end). RETROFITTED LIGHT LUMINAIRE LABEL [SKU #: 300220] MEMORY-DIMMABLE LED SEP TUBE-LAMP INSTALLATION INSTRUCTIONS [SKU #: 300554] This decal must be placed in a prominent location on the LED-modified luminaire so that it is visible when replacing an LED tube (only one label per retrofitted luminaire required). Provides information needed to install and operate the Memory-Dimmable LED Tube Lamp. Memory-Dimmable SEP T8 LED Tube Lamp Installation Instructions: STEP Disconnect power to installation site at the breaker box. Ensure that wall switch also is in the OFF position. WARNING: Verify that all power is off using a voltmeter or other method. STEP 2 Remove Lens Lamps Removed Remove Ballast Cover Remove troffer lens, if present. Remove existing fluorescent or LED tube lamps by rotating one quarter turn and sliding each lamp out. Dispose of fluorescent tube lamps per job/company site rules and regulations. Remove ballast cover. (Cover may be secured with screws or tabs.) NOTE: When installing these LED tube lamp(s) in a previously retrofitted luminaire with a single-end power source, do not remove ballast cover and skip to STEP 5 below.

STEP 3 (Ballast Bypass) Cut all ballast wires as close to ballast as possible, and then choose one of the following options: - Unscrew screw(s) and remove ballast from luminaire. Then reinsert original screw(s) into ballast mounting hole(s). Ballast Remove Socket Covers, Both Ends Cut & Remove All Wires, One Troffer End Only Cut Ballast Wires Remove Socket Covers Remove Wires OR - Abandon and leave ballast in its original mounting location. Remove lamp-holder (socket/tombstone) covers from both ends of luminaire. (Covers may be secured with screws or tabs.) Cut and remove all wires from the sockets at ONE END of luminaire. (Only one side of luminaire needs wired sockets.) STEP 4 (SEP Tube Wiring) If you have ordered one of RVLT s SEP Socket Retrofit Kits, remove existing powered tombstones and install kit per instructions. Ensure that powered sockets are wired according to diagrams labeled Wiring After Retrofit, which depict 2-, 3-, and 4-tube SEP configurations. Cut and strip approximately /2 of insulation from the free ends of the hot (black) and neutral (white) socket wires. Splice the hot and neutral incoming power leads with the corresponding hot and neutral socket wires using the appropriate wire nuts. Secure all fasteners, clips and wires (use electrical tape if necessary) and reinstall socket covers at both ends of troffer. Apply supplied label SKU #300003 with arrow pointing to wired sockets of troffer, indicating modified power socket. Apply Retrofitted Luminaire Label SKU #300220 on inside of luminaire housing near one end of housing, next to powered sockets. Ensure that the label will not be covered by any cover pieces, trim pieces, or other items. If necessary, clean the area where label will be placed before affixing the self-adhesive label.

STEP 5 Read label on the LED tube lamp to ensure that powered end of the LED is aligned with the powered luminaire socket, then insert single-endpowered LED lamp in the normal way by sliding the pins into both tombstone sockets and gently rotating a quarter turn until LED tube locks in place. LED lamp is now fully installed. Repeat above step for all LED tube lamps. Replace ballast cover. Replace troffer lens, if present. Install LED Lamps Replace Ballast Cover Replace Troffer Lens STEP 6 Switch power back on at the breaker box. STEP 7 (Dimming Operation) Luminaires retrofitted with Memory-Dimmable LED tube lamps can be controlled with any ordinary on-off wall switch. DO NOT use a dimmer or dimming switch of any kind with these tube lamps. To operate, turn the wall switch ON. Lamp brightness will gradually ramp up. When lamp brightness reaches the desired level, quickly (< s) turn the light switch OFF and then back ON. The lamp will return to the desired brightness level. To set a new brightness level, turn the lamp off and repeat the above ON/OFF/ON procedure as needed. Note: Simply turning the lamp ON from a starting OFF position will power up the lamp to full brightness. Memory-Dimmable SEP Tube Lamps are dimmable from 00% to 0% of full brightness..