ELECTRICAL SAFET Y FOR CONTRACTORS

Similar documents
Presenter s Notes SLIDE 1

Presenter s Notes SLIDE 1. Before darkening the room, offer a welcome and overview. Begin by introducing the program and its topic:

Electrical Safety Slide Show Presenter s Notes

SAFETY BULLETIN ELECTRICITY THE RULES HOW TO STAY SAFE WHEN WORKING AROUND POWER LINES AMERICAN CONCRETE PUMPING ASSOCIATION

Presenter s Notes SLIDE 1

First Responder Beware

Work safely around power lines.

Before darkening the room, offer a welcome and overview. Begin by introducing the program and its topic:

For Review Only No Copying No Saving No Lending No Posting Online

AVOIDING ELECTROCUTION HAZARDS

Avoidance of Danger from Electricity Overhead Lines and Underground Cables

Work safely. Stowing The Digger. Digging

Electrical Safety in the Workplace

Electrical Safety. Introduction

For your SAFETY. Click Before You Dig, Drill or Excavate. Plan ahead. Dangers of hitting underground lines. May/June 2018

ELECTRICAL HAZARD EXAMPLES

Electricity 101. Understanding the powerful force that empowers our lives.

Close Approach to Power Lines. Close Approach to Power Lines v

Electrical Awareness for Construction Activities. Overhead Power Lines & Underground Cables

Stay Safe Around Electricity Teacher s Guide

Key Issues and Considerations when for. Working around Concrete Pumps, Concrete Pump Trucks, and Crane Lift Buckets

STATISTICS ELECTRICAL INCIDENTS IN ALBERTA. January 1 to December 31, 2017

"ELECTRICAL SAFETY IN THE WORKPLACE"

Wind and Temperature Tip Over Hazard Do not add notice boards or similar

STATISTICS RE: ELECTRICAL INCIDENTS IN ALBERTA to

EZ Hauler 2500 Training & Procedure Manual

STAY SAFE NEAR ELECTRICITY

Boom Lift Platform Capacity Reduction Manual. For Set Lighting Technicians and Studio Grips

STATISTICS ELECTRICAL INCIDENTS IN ALBERTA. January 1 to December 31, 2012

Q: True or false? The slow-moving vehicle emblem is only to be displayed on tractors? a) True. b) False

In the Interest of Safety

Mini Skid Steer Training

Begin Program: Welcome everyone and introduce yourself, speaker(s) and/or interpreter if one is present/necessary. Feel free to include your name/prog

36CSR27 TITLE 36 LEGISLATIVE RULE BOARD OF COAL MINE HEALTH AND SAFETY SERIES 27 RULES AND REGULATIONS GOVERNING SURFACE AREAS

GUIDELINE FOR DELIVERING TO CONCRETE PUMPS

"CRANE SAFETY IN CONSTRUCTION ENVIRONMENTS"

OVERHEAD CRANE SAFETY:

Important. Contents. Contact us:

Electrical Hazards in Construction

Safety Training Topic ELECTRICAL SAFETY

PRESENTER'S GUIDE "CRANE SAFETY" Part of the "SAFETY MEETING KIT" Series Quality Safety and Health Products, for Today...

PRIVATELYOWNED POWER POLES AND POWERLINES

WIRING DESIGN & PROTECTION REQUIREMENTS CHECKLIST

LIFT TRUCK SAFETY OPERATOR TRAINING

Electrical Safety For Everyone. Leader s Guide

New Bremen, Ohio USA 2004 PF14387-WEB Rev. 6/06 Printed in U.S.A.

OSHA Update. Electric Power Generation, Transmission and Distribution Standard (Part 1910 & 1926)

FATAL AND SEVERE RISK PROGRAM

CRANE OPERATION INSTRUCTION AND GUIDELINES

UNITED STATES DEPARTMENT OF LABOR MINE SAFETY AND HEALTH ADMINISTRATION Metal and Nonmetal Mine Safety and Health REPORT OF INVESTIGATION

WORKING SAFELY NEXT TO WEST MIDLANDS METRO

PLATFORM WHEEL WELL ACCESS STAND

STATISTICS ELECTRICAL INCIDENTS IN ALBERTA. January 1 to December 31, 2013

LADDER SAFETY ISSUES IN ROOFING

Cranes. OSHA Office of Training & Education 1

An average of one worker is electrocuted on the job every day There are four main types of electrical injuries:

TEMPORARY SERVICE TABLE OF CONTENTS PUD SERVICE TERRITORY AND CONTACTS CHAPTER ONE - INTRODUCTION CHAPTER TWO - TEMPORARY OVERHEAD SERVICE

EEI Occupational Safety & Health Committee Conference Public Safety Issues and Trends

Aerial Lifts. Man-lifts are electric or air-powered compact lifts that allow units access through standard doorways and operation in narrow corridors.

Important. Contents. Contact us:

Quarterly Training Summit October 2016

WARNING this attachments capacity changes depending on the Skid Steer Loader it is hooked up to. CAPACITY AT 24 LOAD CENTER

Electrical Safety World Video Episode 1 Electricity Basics

Private Overhead Electric Lines. Safety and Responsibility

Operator Manual. This operator manual has. information for all models. of series M plus some. options and accessories. Some of the illustrations

In This Document MODULE DESCRIPTION This module provides information on the safety concerns and

Grease Stand MODEL# DF MAINTENANCE AND OPERATION MANUAL. Page 1

Operator Manual. The most important component is you. This operator manual. has information for. all models of series. B plus some options and

Today, we re going to talk about battery safety. We ll discuss all the key issues associated with using batteries safely, including battery hazards,

STATISTICS RE: ELECTRICAL INCIDENTS IN ALBERTA to

Look Out Look Up! Campaign toolkit. January 2018

Actsafe Safety Bulletin #23 WORKING WITH LIGHTING SYSTEMS AND OTHER ELECTRICAL EQUIPMENT

Excavation worker killed by flying rigging when hook fails

The Shocking Truth About Electrical Safety Teacher s Guide

Newport News Shipbuilding Contractor Environmental, Health and Safety Resource Manual Cranes

Electrical Safety. Electrical Safety Webinar. Electrical. Printing Industries Alliance Printing Industries Alliance 1

Monthly promotions. October 2018 Puget Sound Energy bill inserts and information. Download inserts

Working in Proximity to Overhead Power Lines

STANDARD OPERATING PROCEDURES. ELECTRICAL HAZARDS SAFETY PROCEDURES PURPOSE: To provide safety procedures for the removal of electric meters,

2006 Machinery Operation Exam Kansas Hazardous Occupation Training

Maintenance and Operation Manual for Landing Gear Access Stand

PW Operator Manual PW This operator manual. has information for all. models of series PW plus some options. and accessories.

RAPID ROLLER OPERATOR S MANUAL. L&C ENTERPRISES - U.S.A, Inc N.75 Drive, Escanaba, MI OWNER S NAME MODEL

4 B High Do not allow anyone except the signal person in the working area

Guidelines when working near TasNetworks electrical assets

LOS ANGELES UNIFIED SCHOOL DISTRICT

ELECTRICAL SAFETY. Leader s Guide. Marcom Group Ltd.

Surface Regulations and Policies

Boring Unit Sitework Systems Attachment

U.S. Department of Labor U.S. U.S. Department of Labor Mine Safety and Health Administration 1/18/17

1. Cranes. 3. Hazardous Chemicals. 4. Signs. 2. Trenching and Excavations

The Ten Commandments of Tractor Safety

OVERHEAD & GANTRY CRANE / RIGGING

Unrestricted. S.Mukhopadhyay

SBRL-SERIES SPREADER BEAMS INSTRUCTION MANUAL

Highway worker crushed by swinging backhoe boom

SECTION 14: AERIAL LIFT PROGRAM

Uncontrolled When Printed Supersedes GERT8000-DC Iss 2 on 01/03/2014. Module DC. GE/RT8000/DC Rule Book. DC electrified lines. Issue 3.

CPCS renewal test factsheet

Operator Manual. TR 3600 SERiES. The most important component is you. This operator manual. has information for all. models of TR 3600 series

Transcription:

ELECTRICAL SAFET Y FOR CONTRACTORS

TABLE OF CONTENTS Electricity Demands Respect... 2 Before Starting to Work Let Us Help You...2 Basic Rules for Electrical Safety...2 Common Dangers for Contractors...3 For Underground Safety, Call for Cable Location...4 What State Law Says...5 If an Accident Does Happen, Don t Panic...5 Working Near Power Lines...7 In the Event of Electrical Contact... 11 Bailout Procedure... 13 Quick References... 16 Emergency Instructions... 16 1

Electricity Demands Respect Electricity can shock, burn, or kill if not handled properly. It always seeks all paths to ground. If you, or any other type of conductive material (metal, wood, trees, machinery/equipment, tools, etc.), get to close to or touch the power lines, you may provide this immediate path to ground through your body. This will result in severe injury or death. Before Starting to Work Let Us Help You Be observant. If you have work to do near power lines or power facilities always consider them to be energized or HOT. Call Snohomish County PUD. We want to help review safe working conditions for you at your site. If needed for your safety, we may decide to turn off electricity or other take measures. Because it takes time to do this work, plan your job ahead and let us know. For example, if it is feasible to take lines out of service, advance notice is required. There may be a charge for work performed by the PUD. If you need more information or have safety concerns, call the PUD at 425-783-8272 (Toll-free in Western Washington and outside the Everett local calling area at 1-877-783-1000, ext. 8272). Basic Rules for Electrical Safety Work at a safe distance from all power lines and facilities. Ten feet is considered a minimum clearance for objects, tools and people when working near overhead lines of 0 to 50,000 volts. Never assume power installations are insulated. (For minimum clearance on voltages above 50,000 volts, see WAC 296-155-428.) 2

Cranes, derricks and hoists used in construction have additional clearance requirements; see WAC 296-155-53408. Plan your work ahead. If your equipment will be operating in the vicinity of a power facility, check to make sure there is no possibility of accidentally striking a line or digging into an underground cable. Don t get close to or touch electrical equipment. NEVER attempt to move or raise electric lines or equipment. If you need help to make power lines safe, or need to report damage or hazards, call the PUD. Also call the PUD, if you have any doubts or questions about the safety of the work area. Common Dangers for Contractors Digging trenches or excavating in areas where there may be underground utility installations is dangerous and expensive. Call the Utilities Underground Location Center at 811 or 1-800-424-5555. The law requires the Location Center be contacted at least two (2) business days prior to starting excavation. It is a free service! Equipment near lines may accidently come in contact with the line, injuring the worker. Use extreme caution when carrying ladders, scaffolding poles, piping, or high-rise metal tools near power lines. Heavy or large equipment may accidently be driven directly into lines. Take care when operating cranes, front-end loaders, backhoes, concrete pump trucks, or farm equipment such as augers. 3

Be aware of obstructed views. Equipment with a boom or part that may contact the power line when extended can be hazardous when trees or other objects obscure a worker s view of lines. When accidental contact is possible, make sure workers not operating the equipment are not in contact with the equipment and touching ground at the same time. Underground Safety If your job requires excavation, to meet the requirements of the law, simply call this number at least two business days prior to starting such excavation: Utility Underground Location Center 811 or 1-800-424-5555 Digging into utility cables is dangerous and expensive. RCW 19.122.040, RCW 19.122. 070, WAC 296.155.655(2) and WISHA rules require before opening an excavation or trench, underground utilities such as sewer, telephone, fuel, electric, water line, or other installations shall be located. When excavation operations approach the location of underground installations, the exact location of the installations shall be determined by safe and acceptable means. If electric lines are found, the appropriate utility companies shall be notified and a qualified person from the utility shall make positive identification and take the necessary steps to protect lines from the work area. An excavator who damages underground facilities and failed to contact the Utilities Underground Locating Center or Snohomish County PUD, as required, could be held responsible for triple the damage cost. 4

What State Law Says For your safety, review the Washington Administrative Codes for Construction Workers (WAC 296-155) Part I (Electrical), and Part N (Excavations, Trenching and Shoring). It also requires that a minimum of ten feet be maintained from energized overhead high voltage electrical conductors (for voltages of up to 50,000 volts) with additional distance required for higher voltages (example: 12 feet 2 inches for 115,000 volts). For minimum clearances for cranes and derricks see WAC 296-155-Part L. For exact distances and other requirements of the law when working near power lines, refer to the appropriate sections in WAC 296-155. If an Accident Does Happen, Don t Panic! There are a number of basic steps to follow in case of an electrical accident: Do not touch the injured or any lines or equipment in contact with the injured. Even if it appears that the accident caused the line or equipment to be de-energized, use caution. Call 911 and report the accident immediately. ALWAYS assume the power lines are HOT. Modern electric lines usually relay back into service and become energized several times within a matter of seconds following an accident, or its possible under certain conditions the system may not see the problem and may not deenergize the line or equipment at all. Prevent others from approaching the victim and any electrically energized vehicles, objects, or structures. 5

If the electricity to a construction site accident is controlled by a construction site circuit breaker under site control, open it if it can be done safely. A serious electrical injury will cause muscles to contract, making it difficult or impossible for a victim to pull free from an electric source, which is still energized. Cutting off the power will usually free the victim if the right breaker was opened DO NOT ATTEMPT TO DE-ENERGIZE HIGH-VOLTAGE POWER LINES. CALL THE PUD IMMEDIATELY! Send for help. Call 911 to notify both the police and the fire department. Also call Snohomish County PUD at 1-800-783-1000 so the electricity can be turned off. If a vehicle is involved and lines are touching it, anyone who touches the vehicle while standing on the ground may be shocked or electrocuted. If it is your vehicle, sit quietly inside and wait for help to arrive. If bystanders arrive, roll down the window, and shout to them to stand at least 15 feet clear of the vehicle so they are not shocked or electrocuted and call 911 for help. You are safe inside the vehicle as long as you do not step out and touch the vehicle and ground at the same time. Remember that the electricity is not only traveling through the vehicle, but is also traveling in the ground around the area. If the vehicle is on fire and it is necessary to leave it, open the door and jump clear of the car, avoiding wires that may be on the ground. Stay calm and jump carefully so you don t fall back against the car or touch the ground and vehicle at the same time. Then shuffle with both feet together clear of the area, keeping both feet touching the ground at all times. Continue shuffling to at least 15 feet away from the accident. 6

Working Near Power Lines High voltage contact is the largest single cause of fatalities associated with cranes and derricks. All these could be prevented. Most power companies or utilities will consider (if given advance notification) shutting down the line temporarily or moving the line. If it is not possible to have the line moved or the power shut off, the following procedures should be enforced by the project supervisor and strictly followed by all operators. Review clearance requirements in WAC 296-155-53408. OPERATORS Before setting up or operating on any project look for power lines and if present, know your clearances, maintain them and exercise extreme caution. SITE SUPERVISOR When powerlines are present on or near the site, the safety of the crane operation is totally the responsibility of the personnel in charge of the job site and the crane operator. Establish clearances and enforce required safe work procedures to prevent contact. PRE-JOB PLANNING: Address power line problems during pre-job planning after the first site survey is made by a contractor. Resolve problems prior to the crane/derrick arrival to avoid job delays and prevent accidents. 7

20 ft. 50 ft. Up to 350 kv Over 350 kv (1) Keep your distance. The area surrounding every live power line is referred to the clearance limit of approach. It is strictly forbidden to move any crane/derrick boom, load line, or load into this area unless proper steps are followed. Without knowing the voltage, the law requires you to ensure no part of the crane/derrick, load line or load (including rigging and lifting accessories), gets closer than twenty feet to a power line that is up to 350 kv or closer than fifty feet to a power line that exceeds 350 kv. Once the voltage has been determined and the crane/ derrick needs to get closer to the line/equipment than these distances, there are options/exceptions you may consider to reduce the clearance in WAC 296-155-53408 (2) that must be followed when needed. (2) Notify the utility company when and where any crane/derrick is to be working near power lines where you are not sure of the voltage and clearance or need assistance in maintaining the clearances. (3) Treat all wires/electrical equipment as HOT until you have reliable a qualified utility worker confirms the system has been de-energized and properly protected. 8

Clearance of approach Clearance of approach Need signalman Do not need signalman (4) Except for the operator, keep ALL personnel well away from the crane/derrick whenever it is working close to power lines. If the crane operator accidentally makes contact with the energized line, anyone who touches the equipment and ground at the same time will probably be shocked or electrocuted. (5) Don t allow anyone to touch the load, the crane/derrick, or the crane/derrick hook until the signalman indicates that it is safe to do so, i.e., the crane/derrick is out of the wires. (6) When a tagline is needed to control a load that could accidently sing into the restricted zone the taglines must be of a non-conductive type material and keep clean and dry when used for this purpose. Again, taglines must not intentional violate the minimum clearance requirements. (7) Slow down the operating cycle of the machine by reducing hoisting, booming, swinging, and travel speeds. (8) Exercise extreme caution when working near overhead lines having long spans as they tend to swing laterally in the wind and accidental contact could occur. 9

(9) Exercise extreme caution when traveling the crane/ derrick as uneven ground can cause the boom to weave or bob into the lines. (10) Ensure that whenever a crane/ derrick must travel beneath power lines, clearances and other requirements in WAC 296-155-53408 (5) are followed. Taglines can conduct electricity! (11) The operator should not leave the crane/ derrick if the boom, when lowered, can enter the clearance limit. Clearance limit 10

In the Event of Electrical Contact: (1) Remain inside the cab DO NOT PANIC! You should be safe where you are. DO NOT TRY TO GET OFF THE MACHINE, TOUCHING IT AND THE GROUND AT THE SAME TIME. Call the PUD at 425-783-1000, for help or call 911 and they will contact the utility. (2) Instruct all other personnel to keep at least 15 feet away from the machine, ropes, and load. The complete machine, load, and the ground around it could be HOT. (3) The machine operator may try to remove the contact (only if it is safe to attempt). Unaided and without anyone approaching the machine, try to remove boom away from the line/equipment. Move away from the line in the reverse direction to that which caused the contact (for example, if you swung left into the wire, swing right to break the contact). Do not panic. 11

Remember: Once an arc has been struck, it can draw out a considerable distance before it breaks, so keep moving away from the line until the arc breaks and then continue moving until you are at least 15 feet away from the line. CAUTION: If the boom or loads line appears to be welded to the power line, do not move away from the line as the line may break and fall to the ground. Stay where you are until help arrives. (4) Remain inside the machine. If the machine cannot be moved away or disengaged from the contact, remain inside until a qualified electrical utility worker de-energizes the circuit and confirms that conditions are safe. (5) Report every incident involving contact with a live line to the electrical utility so that inspections and repairs can be made to prevent damaged powerlines from falling at a later date. Accidental contact from power line swaying in the wind 12

Bailout Procedure If the operators decide to leave the machine, they must JUMP CLEAR. They must never step down allowing part of their body to be in contact with the ground while any other part of the body is touching the machine. HIGH VOLTAGE CONTACT will result in electrical current flowing down the boom and through the machine to the ground. The ground will then be energized with high voltage near the machine and lower voltage farther away in rings or potentials (like ripples on water or like a dartboard). 13

WRONGg g RIGHT (BUT STILL DANGEROUS) Never leave the machine unless absolutely necessary! 14

There is something called step and touch potential which states that if you have one leg in a ring (or potential) that has high voltage and take a step, putting your other leg in another ring (or potential) that has low voltage. This could result in electricity traveling up one leg, and down the other to ground, and you could be shocked or electrocuted. Because of the hazardous voltage differential in the ground, the operator should stand on the door ledge (rocker panel), jump clear with both feet together making sure not to touch the vehicle and ground at the same time with ANY part of their body. Land with both feet together on the ground, maintain balance and shuffle with both feet together slowly away from the vehicle for at least 15 feet. Do not take large steps because it is possible for one foot to be in a high voltage area and the other to be in a lower voltage area. The difference between the two can kill. Voltage Differential 15

Quick References Snohomish County PUD switchboard...425-783-1000 Customer Service...425-783-1000 Engineering...425-783-8272 Safety... 425-783-5555 or 425-783-5557 Utilities Underground Location Center... 811 or 1-800-424-5555 or www.wucc.org Emergency/Fire/Police... 911 EMERGENCY INSTRUCTIONS 1. DO NOT PANIC! 2. Do not touch the victim or anything in contact with the victim. They could still be energized. 3. Try to de-energize the electrical source if it is safe and possible to do at the circuit breaker (customer owned equipment only). 4. Send for help call 911 and the PUD. 5. Once the electrical source has been deenergized, provide immediate first aid to the victim. 16

This brochure has been prepared to provide a basic understanding of the potential hazards involved when working near energized underground or overhead power lines, and the need to use extreme caution when in the vicinity of the HOT lines. It doesn t provide all the required safe work rules and should not be used for employee training purposes. Because it also contains emergency information in case an accident occurs, we suggest that you read it carefully and keep it handy for a quick reference.

PUD Contact Numbers: Customer Service 425-783-1000 Safety Department 425-783-5555 Engineering 425-783-8272 Tree Trimming (Vegetation Mgmt.) 425-783-5579 Toll-free in Western Washington and outside the Everett local calling area: 1-877-783-1000 CALL BEFORE YOU DIG If your job requires any excavation, you must call the Utility Underground Location Center at 811 or 1-800-424-5555 at least two business days before starting such excavation (www.wucc.org) Snohomish County PUD PO Box 1107 Everett WA 98206-1107 FORM 1604 Rev. 6/12 Printed on recycled paper