Class R 250V and 600V modular ferrule and knifeblade fuse blocks

Similar documents
Class J modular ferrule and knifeblade fuse blocks

Up to 60 A Class R 250 V and 600 V ferrule power distribution fuse blocks

BH-1 modular fuse blocks, 700 V, 400 A

UL Recognized power distribution blocks

Fusetron FRN-R Class RK5 250Vac/125Vdc A, dual element, time-delay fuses

Electric vehicle auxiliary fuses 500 Vdc, A

BUSSMANN. CUBEFuse Compact Circuit Protector Base (CCPB) SERIES. Technical Data Effective April 2017 Supersedes April 2016

Low-Peak LPJ Class J 600Vac/300Vdc, 1-60A, dual element, time-delay fuses

FRNR A 250V TD Class RK5 Dual Elem Fuse-Fusetron

CHCC_ (Class CC) CHM_ (UL midget/iec 10x38) CHPV_ (13/32 x 1-1/2 and 10x38 photovoltaic)

CHCC_ (Class CC) CHM_ (UL midget/iec 10x38) CHPV_ (13/32 x 1-1/2 and 10x38 photovoltaic)

6.3 mm reverse quick connect

Compact Circuit Protector (CCP)

Compact Circuit Protector (CCP) 1-, 2- and 3-pole Class CC, Midget, 10x38mm

BUSSMANN. Pre-production and sample electric vehicle power fuses 500 Vdc, A SERIES. Technical Data Effective December 2018.

Bussmann series Quik-Spec Power Module Switch elevator disconnect

LKN A 250V Super-Lag Fuse Link. Features amperage rating 200 class Voltage Rating 250. Long Description. Manufacturer Information

N0N A 250V One-Time Class H Fuse

Compact Circuit Protector

Complete and reliable solar circuit protection

BUSSMANN. LIMITRON FNQ-R Class CC 600Vac, A, time-delay fuses SERIES. Technical Data Carton quantity: Catalog symbol: Dimensions - in:

Effective December 2015 Supersedes September 2013

up to 30A limited by conductor size Operating and storage temperature:

Compact Circuit Protector (CCP)

BUSSMANN. Next generation Compact Circuit Protector (cat. no. CCP2) SERIES. For use with Class CC, Supplemental and IEC 10x38 mm fuses

Volts: 600V Amps: up to 30A limited by conductor size Withstand: 200kA RMS Sym. Operating and storage temperature:

The easiest and fastest way to select and specify the right fuse

PT Medium voltage fuses for potential and small power transformers

Compact Circuit Protector (CCP)

Low-Peak 600V Class RK1

Bussmann 10x38mm Photovoltaic fuses 1000Vdc, 1-30A

Low voltage, branch circuit fuses

Compact Circuit Protector (CCP)

LPSRK30SP 30A 600V TD Dual Elem Class RK1 Low Peak Fuse

Compact Circuit Protector (CCP)

CUBEFuse. CUBEFuse catalog numbers (amps)

Fuse holders and blocks

LPSRK100SP 100A 600V TD Dual Elem Class RK1 Low Peak Fuse

Specification made simple for selective coordination in a compact size

NH DIN Dual Indication Fuse Links Class am, 690Vac, 6 to 500 Amps, Sizes 000 to 3 NH Series

FRNR A 250V TD Class RK5 Dual Elem Fuse-Fusetron

LPCC3 3A 600V TD Class CC Low Peak Fuse. Features amperage rating. Dimensions and Weight. Long Description. Manufacturer Information

Low Voltage, Branch Circuit Rated Fuses

Compact Circuit Protector

BUSSMANN. 8.3kV E-Rated SERIES. Medium voltage fuses for feeder circuit, switchgear and transformer. protection. Technical Data 10352

Class H & K Fuse Holders - 250/600 Volt

Quik-Spec Coordination Panelboard Specifications

R6F30A1S R6F30A1S 1P 60A 600V Fuse BLK. Features. Long Description

The easiest and fastest way to select and specify the right control circuit fuse

Bussmann. Circuit Protection Solutions

Class gg/gl, 690Vac, 2 to 500 Amps, Sizes 000 to 3 NH Series

Quik-Spec Coordination Panelboard A fusible panelboards

I power distribution. Blocks. challenges. Finger-Safe / FSPDB Series...I2. MPDB Open-Style PDBs... I4. MPDB62-MPDB63 (Mini) Open-Style PDBs...

A powerful way to manage your power distribution challenges. I Power Distribution Blocks

Section Contents. Disconnect Switches

LOW-PEAK Time-Delay Fuses KRP-C Class L 600 Volt A

Fast-acting supplemental fuse. For superior protection, Bussmann recommends upgrading to Low-Peak Class CC fuses. See data sheet # 1023.

footprint of traditional fusible switches

LFJ602003C 200A 600V Fus Block

Reduce Downtime With Quick Access to the Right Replacement Fuse

Industry s most comprehensive medium voltage circuit protection

Fuse Accessories. Bussmann - Fuse Holders. Fuse Holders

Open-Style Power Distribution Blocks

600 A 15 and 25 kv class Cleer grounding elbow

Power Distribution Blocks

Spring Reinforced. 30A & 60A Box. Spring. 30A Screw (R) Spring. 30A Screw. Spring Reinforced. 30A Pressure Plate

Quik-Spec Coordination Panelboard A fusible panelboards

Gears & Fuse Gears. American General Purpose Fuses Cylindrical & Blade Fuse Blocks Class H, K & R CLASS H, K AND R FUSE BLOCKS. Ratings.

T CLASS T FUSE BLOCKS

Fuse & Switch. BUCHANAN Terminal Blocks. Product Facts High Density Blocks. Fuse Blocks. Switch Blocks. Common Features of 300 & 0300 Series

Products for enhancing electrical safety and reliability

Class T 300 & 600 Volt Fuse Blocks F B 300 & 600V CLASS T FUSE BLOCKS RATINGS: FEATURES/BENEFITS: RECOMMENDED FUSE USAGE: CLIP & CONNECTOR TYPES

IEC TERMINAL BLOCKS. Screw Clamp Connection. Feed Through DIN Rail 433. Ground DIN Rail 439. Fuse Holder DIN Rail 445. Disconnect DIN Rail 448

Selection and application guide

5 x 20mm Fuses S500 Series, Fast-Acting, Glass Tube

LH600303C 1/10-30A 3P 600V Class H Box Lug Fuse Block

Bussmann Open and Enclosed Rotary Disconnect Switches. Exceptional Breadth and Availability for Your Application

Red Spot Fuse Holders

R-Rated medium voltage fuses for motor circuit protection

Open-Style Power Distribution Blocks

Terminal Blocks. Section 12. Control Catalog 12-1

Compact Modular Fuse Holders With the Industry s Best Ratings Products for PV, IEC and UL Applications

XL Style Photovoltaic Fuse Links for Solar Panel Applications 50 to 630A, 1000 & 1500Vdc PV Series

Modulostar US10 Modular fuse-holders

R-Rated medium voltage fuses for motor circuit protection

Bussmann series Quik-Spec Coordination Panelboard

C308F 3 mm x 8.4 mm fast-acting, ceramic tube fuses for hazardous applications

Ferrule fuses. High Speed Fuses

UltraSafe US22 Modular fuse-holders

POWR-BLOKS. POWR-GARD Blocks and Holders Datasheet. Distribution Blocks Splicer Blocks Covers. Connectors. Ampere Ratings. Description.

DBL distribution blocks 3x1 pole

Red Spot Fuse Holders

Section 10: Terminal Blocks

Premium industrial grade isolated ground straight blade receptacles

Bussmann series NH catalogue. Leadership in circuit protection

DIN Dual indication fuse links

LF Series Class H/K5 and r Fuse blocks

Assembly not available for new installations.

Bussmann series NH bases

S505SCH 5 x 20 mm Time-delay, high I 2 t, axial lead, ceramic tube fuses

Transcription:

Technical Data 1048 Class R 2V and 600V modular ferrule and Knifeblade fuse blocks from 100 to 600 amps feature phase barriers between poles for additional safety with up to four mounting holes per pole increase installation flexibility. All knifeblade blocks meet UL creep and clearance requirements for Industrial Power Circuits (UL 8 and UL 845). Additionally, the 200 to 600 amp blocks meet the higher UL creep and clearance requirements for Power Distribution Standards (UL 8, UL 67, UL 48, UL 81 and UL 86A) All blocks have optional IP20 finger-safe high clarity, see-through covers for inspecting wire terminations or thermography measurements without removal. All covers enhance safety by featuring probe holes for easier, safer testing and a lockout/tagout capability. These covers also have optional open fuse indication to speed troubleshooting. Easy circuit identification is available for 30 and 60 amp blocks and covers with universal marker labels. Catalog symbol: RM25_ (2V) RM60_ (600V) Description: Bussmann series Class R modular fuse blocks increase versatility, reduce labor and enhance safety for any panel or electrical system design. Available for the full Class R fuse amp range. These fuse blocks feature a standard fuse clip reinforcing spring for enhanced electrical contact between the block and fuse. All blocks are available as single-pole versions that snap together for the required number of poles, or as factory configured 2-, and 3-pole versions to meet stocking requirements. The modular design permits reducing inventory, assembly time and labor with tool-less assembly of multiple poles at point of use. Ferrule fuse blocks up to 60 amps save panel space with the smallest width dimension on the market and feature DIN-Rail and panel mount versatility so that one product can be used for multiple applications with lower inventory cost. Specifications: Ratings Volts 2V 600V Amps up to 600 Withstand 200kA RMS Sym Agency information Blocks: UL Listed E14853 IZLT and IZLT7 CSA Certified 472-6225-01 CE RoHS Compliant REACH declaration available upon request Covers: UL Listed E58836 - JDVS CSA Certified 472-6225-01 (30 and 60A) RoHS Compliant REACH declaration available upon request

Technical Data 1048 Poles 1-, 2-, 3-pole units factory assembled Single-pole units snap together to create desired number of poles Flammability ratings Blocks: UL 4V0, self-extinguishing Covers: UL 4HB, self-extinguishing Class R 2V and 600V modular ferrule and Optional see-through covers provide IP20 finger-safe protection and feature a lockout/tagout provision to improve electrical safety. These covers are also available with open fuse indicating version for faster troubleshooting. Order separately, one cover per block pole. Operating and storage temperature range Blocks -40 C to +120 C Covers Non-Indicating -40 C to +120 C Indicating -20 C to +0 C* * Indication requires minimum 0V and closed circuit to illuminate. Materials Base: Thermoplastic Terminals Tin-plated copper brass (30 and 60A) Tin-plated aluminum (box lug) Covers:Thermoplastic Conductors Dual lugs on 600A blocks for easier wiring using two, smaller conductors. See catalog numbers for details and torque specifications Class R ferrule fuse blocks Class R 30 and 60 amp ferrule fuse blocks have DIN-rail and panel mounting capability, the modular designs allows blocks toand snap together for the desired number of poles. They accept optional snap-on covers for IP20 finger-safe protection and feature a lockout/tagout to improve electrical safety. 100 to 600 amp are panel mount with multiple holes for installation flexibility and the modular design allows blocks to snap together for the desired number of poles. They accept optional snap-on covers for IP20 finger-safe protection and feature a lockout/tagout provision to improve electrical safety. 2

Class R 2V and 600V modular ferrule and Technical Data 1048 Table 1: Class R 2V 30 and 60 amp block catalog numbers Fuse amp range up to 30 to 60 Terminal type Optional covers* Box lug/ Box lug/ #10-32 Phil-slot Screw with Poles slot screw hex screw screw quick-connect Pressure plate Indicating** Non-indicating 1 RM230-1CR RM230-1CHR RM230-1SR RM230-1QR RM230-1PR 2 RM230-2CR RM230-2CHR RM230-2SR RM230-2QR RM230-2PR CVRI-RH-230 CVR-RH-230 3 RM230-3CR RM230-3CHR RM230-3SR RM230-3QR RM230-3PR 1 RM260-1CR RM260-1CHR 2 RM260-2CR RM260-2CHR CVRI-RH-260 CVR-RH-260 3 RM260-3CR RM260-3CHR * Covers sold separately, order one cover per pole. ** Open fuse indication requires 0 volts minimum and closed circuit to operate. Table 2: Class R 2V 30 and 60 amp block terminals and conductors Terminal type Box lug #10-32 Phil-slot screw Screw with quick-connect* Pressure plate AWG type/ range C Cu 2-14, AL 2-8 /0 C Cu 10-18 Torque AWG Nm (lb-in) 2-3 5 () 4-6 5.1 (45) 8 4.5 (40) 10-14 4.0 () 10-18 2 (20) * 3/16 Quick-connect terminal maximum ampacity dependent on female spade connector and wire ratings. Recommended Bussmann series fuses: Description Volts Amps Data sheet no. Ultimate protection time-delay Low-Peak LPN 2V up to 60 1003 Advanced protection fast-acting Limitron KTN-R 2V All 1043 Advanced protection energy efficient time-delay Fusetron FRN-R 2V up to 60 101 Recommended accessories for 30 and 60 amp blocks: Description DIN-Rail end stops Marker labels Catalog no. BRKT-ND BRKT-NDSCREW2 TM26CB Finger grips on cover for easy removal Optional seethrough, snap-on cover for easy visual inspection Standard phase barriers for additional safety Optional open fuse indication speeds troubleshooting Vent slots improve cooling* Toolless interlocking modular design for easy point-of-use assembly Lockout/tagout feature improves safety Probe holes for easy testing without removing cover DIN-rail or panel mounting on each pole provides installation flexibility *No fuse derating necessary. 3

Technical Data 1048 Class R 2V and 600V modular ferrule and Dimensions; 30A, 2V Class R block - in (mm) 26 1.0 RM230-1CR 80 3.2 RM230-2CR 25 1.0 4 1. PROVISION FOR MARKER LABEL 15 25 1.0 PROVISION FOR MARKER LABEL 2. CVR-RH-230 (NON-INDICATING) CVRI-RH-230 (WITH INDICATION) RM230-3CR 3. 74 2. LOCKOUT- TAGOUT RING 45 1 4

Class R 2V and 600V modular ferrule and Technical Data 1048 Dimensions; 60A, 2V Class R block - in (mm) RM260-1CR 108 4.2 4.2 3.1 7 6.2 32 1.2 RM260-2CR 34 1 47 1 6 68 103 4.1 58 2 34 1 1.7 PROVISION FOR MARKER LABEL RM260-3CR 1 5 103 4.1 102 4.0 LOCKOUT - TAGOUT RING CVR-RH-260 (NON INDICATING) CVRI-RH-260 (WITH INDICATION) 5

Technical Data 1048 Class R 2V and 600V modular ferrule and Installing/removing covers Install cover: Position cover over block and push straight down until it snaps/clicks into place. For larger conductors, trim center tab at notch as show in detail A. Trim tab here Open cover: Using both outside handles, pull straight up. A Detail A Installing blocks on DIN-Rail Place one edge of DIN-Rail in fuse block base, then rotate block down until it clicks into place. 6

Class R 2V and 600V modular ferrule and Technical Data 1048 Table 3: Class H 2V 100 to 600 amp knifeblade blocks and covers Fuse amp range Poles Catalog nos. 70-100 1 RM200-1CR 2 RM200-2CR 3 RM200-3CR Covers* Conductors*** Indicating** Non-indicating Solid and stranded Fine stranded Torque Nm (lb-in) Cu 1-3 AWG 6.2 (55) 1/0-3 AWG; (2) Cu 4-6 AWG Cu 4-6 AWG 5 () CVR-RH-200 CVRI-RH-200 2 4-6 AWG; (2) Cu 8 AWG Cu 8 AWG 5.1 (45) 8 AWG; (2) Cu 10-14 AWG 4.5 (40) Cu 10-14 AWG; Al 10-12 AWG 4.0 () 110-200 225-400 4-600 1 RM25200-1CR 2kcmil-1 AWG Cu 3/0-1 AWG 42 (3) 2 RM25200-2CR CVR-RH-25200 CVRI-RH-25200 3 RM25200-3CR 2-6 AWG; (2) Cu 2-6 AWG Cu 2-6 AWG 31 (2) 1 RM25400-1CR 600kcmil 57 (0) 2 RM25400-2CR 0kcmil-4 AWG (4) CVR-RH-25400 CVRI-RH-25400 N/A (2) Cu 3/0-4 AWG 57 (0) 3 RM25400-3CR (2) Al 3/0-4 AWG 34 (300) 1 RM25600-1CR 2 RM25600-2CR CVR-RH-25600 CVRI-RH-25600 2 (2) 0kcmil-4 AWG N/A (4) 3 RM25600-3CR * Covers sold separately, order one cover per pole. ** Open fuse indication requires 0 volts minimum and closed circuit to operate. *** Ratings for copper and aluminum conductors except where otherwise noted. Recommended Bussmann series fuses: Description Volts Amps Data sheet no. Ultimate protection time-delay Low-Peak LPN 2V 70 to 600 1004 Advanced protection fast-acting Limitron KTN-R 2V All 1043 Advanced protection energy efficient time-delay Fusetron FRN-R 2V 70 to 600 1020 Finger grips on cover for easy removal Probe holes for easy testing without removing cover Optional seethrough, snap-on cover for easy visual inspection Optional open fuse indication speeds troubleshooting Standard phase barriers for additional safety Vent slots improve cooling* Lockout/tagout feature improves safety Multiple mounting holes for each pole provide flexible, secure mounting Finger-safe wire entry with cutout tabs for larger wires on all versions Toolless interlocking modular design for easy point-of-use assembly *No fuse derating necessary. Dual lugs on 600A blocks for easier wiring using two, smaller conductors. 7

Technical Data 1048 Class R 2V and 600V modular ferrule and Dimensions; 100A, 2V Class R block - in (mm) 171 6.7 61 2.4 1.0 14 22. 61 2.4 55 2.2 14 22. 102 4.0 ALLEN KEY #: 3/16"(5.5MM) 38 1.5 103 4.1 7 13 8.5 1.0 ALLEN KEY #: 3/16"(5.5MM) 38 1.5 103 4.1 7 13 8.5 RM200-1CR RM200-2CR 171 6.7 61 2.4 14 22. 72 2 55 2.2 153 6.0 184 7.2 171 6.7 ALLEN KEY #: 3/16"(5.5MM) 103 4.1 7 13 8.5 67 2 6 70 2 38 1.5 182 7.2 WITH OPTIONAL COVER RM200-3CR 8

Class R 2V and 600V modular ferrule and Technical Data 1048 Dimensions; 200A, 2V Class R block - in (mm) ALLEN KEY #: 3/8"(10.0MM) 68 70 16 8 ALLEN KEY #: 3/8"(10.0MM) 68 70 16 8 136 5 68 1 12 116 4 1 12 116 4 33 1 45 1 45 1 47 1 47 1 68 RM25200-1CR RM25200-2CR ALLEN KEY #: 3/8"(10.0MM) 68 70 16 8 6 3 3.0 1 12 203 8.0 33 1 33 1 1 207 8.1 221 8.7 4 3.7 116 4 220 8.7 WITH OPTIONAL COVER 45 1 47 1 68 68 RM25200-3CR

Technical Data 1048 Class R 2V and 600V modular ferrule and Dimensions; 400A, 2V Class R block - in (mm) ALLEN KEY #:1/2" 80 3.1 80 3.2 21 8 ALLEN KEY #:1/2" 80 3.1 80 3.2 21 8 185 7 42 2 1 16 1 16 12 5.1 12 5.1 71 2 71 2 2 44 44 RM25400-1CR RM25400-2CR 80 3.1 80 3.2 21 42 121 4 105 4.1 ALLEN KEY #:1/2" 277 10. 42 241.5 254 10.0 113 4.5 116 4 1 16 12 5.1 258 10.1 WITH OPTIONAL COVER 71 2 2 2 44 RM25400-3CR 10

Class R 2V and 600V modular ferrule and Technical Data 1048 Dimensions; 600A, 2V Class R block - in (mm) 107 4.2 1 25 1.0 107 4.2 1 8 25 1.0 2. 2. 125 4. 2. 1 16 2. 1 16 155 6.1 ALLEN KEY #:3/8"(10.0MM) 78 3.1 155 6.1 2 7 3 ALLEN KEY #: 3/8 (10.0mm) 2 43 43 78 3.1 2 RM25600-2CR RM25600-1CR 107 4.2 1 25 1.0 2. 1 6.0 1 5 3 14 1 2. 28 1 303 11. 2. 138 5.4 141 5 1 16 155 6.1 ALLEN KEY #:3/8"(10.0MM) 307 12.1 WITH OPTIONAL COVER 78 3.1 2 7 3 2 7 3 2 43 RM25600-3CR 11

Technical Data 1048 Class R 2V and 600V modular ferrule and Table 4: Class R 600V 30 and 60 amp block catalog numbers Fuse amp range up to 30 to 60 Terminal type Optional covers* Box lug/ Box lug/ #10-32 Poles slot screw hex screw Phil-slot screw Pressure plate Indicating** Non-indicating 1 RM60030-1CR RM60030-1CHR RM60030-1SR RM60030-1PR 2 RM60030-2CR RM60030-2CHR RM60030-2SR RM60030-2PR CVRI-RH-60030 CVR-RH-60030 3 RM60030-3CR RM60030-3CHR RM60030-3SR RM60030-3PR 1 RM60060-1CR RM60060-1CHR 2 RM60060-2CR RM60060-2CHR CVRI-RH-60060 CVR-RH-60060 3 RM60060-3CR RM60060-3CHR * Covers sold separately, order one cover per pole. ** Open fuse indication requires 0 volts minimum and closed circuit to operate. Table 5: Class R 600V 30 and 60 amp block terminals and conductors Terminal type AWG type/range AWG Torque Nm (lb-in) 2-3 5 () Box lug C 4-6 5.1 (45) Cu 2-14, AL 2-8 8 4.5 (40) 10-14 4.0 () #10-32 Phil-slot screw /0 C Pressure plate Cu 10-18 10-18 2 (20) Recommended Bussmann series fuses: Description Volts Amps Data sheet no. Ultimate protection time-delay Low-Peak LPS 600V up to 60 1001 Advanced protection fast-acting Limitron KTS-R 600V All 1044 Advanced protection energy efficient time-delay Fusetron FRS-R 600V up to 60 1017 Recommended accessories for 30 and 60 amp blocks: Description DIN-Rail end stops Marker labels Catalog no. BRKT-ND BRKT-NDSCREW2 TM26CB Finger grips on cover for easy removal Optional seethrough, snap-on cover for easy visual inspection Standard phase barriers for additional safety Optional open fuse indication speeds troubleshooting Vent slots improve cooling* Toolless interlocking modular design for easy point-of-use assembly Lockout/tagout feature improves safety Probe holes for easy testing without removing cover *No fuse derating necessary. DIN-rail or panel mounting on each pole provides installation flexibility 12

Class R 2V and 600V modular ferrule and Technical Data 1048 Dimensions; 30A, 600V Class R block - in (mm) 30 6 13. 5 22 7.28 RM60030-1CR 15 6.25 PROVISION FOR MARKING LABEL 2.08 31 1.21 C L 4.16 2.08 60 27 2 6 RM60030-2CR 46 10 58 2.28 PROVISION FOR MARKING LABEL 88 3.48 RM60030-3CR 80 3.13 183 7.21 CVR-RH-60030 (NON-INDICATING) CVRI-RH-60030 (WITH INDICATION) 0 3.53 LOCKOUT - TAGOUT RING 13

Technical Data 1048 Class R 2V and 600V modular ferrule and Dimensions; 60A, 600V Class R block - in (mm) 7 8 RM60060-1CR 5.2 3.1 172 6 RM60060-2CR 3 1 38 1.5 77 3.0 77 3.0 54 2.1 66 2 38 1.5 17.7 PROVISION FOR MARKER LABEL CVR-RH-60060 (NON-INDICATING) CVRI-RH-60060 (INDICATING) RM60060-3CR 82 3.2 202 8.0 116 4 115 4.5 LOCKOUT TAGOUT RING 14

Class R 2V and 600V modular ferrule and Technical Data 1048 Installing/removing covers Install cover: Position cover over block and push straight down until it snaps/clicks into place. For larger conductors, trim center tab at notch as show in detail A. Trim tab here Open cover: Using both outside handles, pull straight up. A Detail A Installing blocks on DIN-Rail Place one edge of DIN-Rail in fuse block base, then rotate block down until it clicks into place. 15

Technical Data 1048 Class R 2V and 600V modular ferrule and Table 6: Class R 600V 100 to 600 amp knifeblade blocks and covers Fuse Covers* Conductors*** amp range Poles Catalog nos. Indicating** Non-indicating Solid and stranded Fine stranded Torque Nm (lb-in) 1 RM60100-1CR Cu 1-3 AWG 6.2 (55) 1/0-3 AWG; (2) Cu 4-6 AWG Cu 4-6 AWG 5 () 70-100 2 RM60100-2CR CVR-RH-60100 CVRI-RH-60100 2 4-6 AWG; (2) Cu 8 AWG Cu 8 AWG 5.1 (45) 8 AWG; (2) Cu 10-14 AWG 4.5 (40) 3 RM60100-3CR Cu 10-14 AWG; Al 10-12 AWG 4.0 () 1 RM60200-1CR 2kcmil-1 AWG Cu 3/0-1 AWG 42 (3) 110-200 2 RM60200-2CR CVR-RH-60200 CVRI-RH-60200 3 RM60200-3CR 2-6 AWG; (2) Cu 2-6 AWG Cu 2-6 AWG 31 (2) 1 RM60400-1CR 600kcmil 57 (0) 2 RM60400-2CR 0kcmil-4 AWG (4) 225-400 CVR-RH-60400 CVRI-RH-60400 N/A (2) Cu 3/0-4 AWG 57 (0) 3 RM60400-3CR (2) Al 3/0-4 AWG 34 (300) 1 RM60600-1CR 4-600 2 RM60600-2CR CVR-RH-60600 CVRI-RH-60600 2 (2) 0kcmil-4 AWG N/A (4) 3 RM60600-3CR * Covers sold separately. ** Open fuse indication requires 0 volts minimum and closed circuit to operate. *** Ratings for copper and aluminum conductors except where otherwise noted. Recommended Bussmann series fuses: Description Volts Amps Data sheet no. Ultimate protection time-delay Low-Peak LPS 600V 70 to 600 1004 Advanced protection fast-acting Limitron KTS-R 600V All 1044 Advanced protection energy efficient time-delay Fusetron FRS-R 600V 70 to 600 1018 Finger grips on cover for easy removal Probe holes for easy testing without removing cover Optional seethrough, snap-on cover for easy visual inspection Optional open fuse indication speeds troubleshooting Vent slots improve cooling* Standard phase barriers for additional safety Lockout/tagout feature improves safety Multiple mounting holes for each pole provide flexible, secure mounting Finger-safe wire entry with cutout tabs for larger wires on all versions Toolless interlocking modular design for easy point-of-use assembly *No fuse derating necessary. Dual lugs on 600A blocks for easier wiring using two, smaller conductors 16

Class R 2V and 600V modular ferrule and Technical Data 1048 Dimensions; 100A, 600V Class R block - in (mm) ALLEN KEY #:3/16"(5.5MM) 112 4.4 55 2.2 ALLEN KEY #:3/16"(5.5MM) 14 1.0 22. 102 4.0 112 4.4 55 2.2 14 22. 7 13 8.5 154 6.1 7 13 8.5 38 1.5 38 1.5 RM60100-1CR RM60100-2CR ALLEN KEY #:3/16"(5.5MM) 112 4.4 55 2.2 14 22. 72 2 55 2.2 153 6.0 222 8.7 234.2 154 6.1 7 13 8.5 67 68 2 233.2 WITH OPTIONAL COVER 70 2 38 1.5 RM60100-3CR 17

Technical Data 1048 Class R 2V and 600V modular ferrule and Dimensions; 200A, 600V Class R block - in (mm) ALLEN KEY #:3/8"(10.0MM) 131 5.2 67 2 70 8 16 ALLEN KEY #:3/8"(10.0MM) 67 2 131 5.2 70 16 32 1.2 1 12 17 7.1 1 12 17 7.1 46 1 46 1 67 2 45 1 45 1 RM60200-1CR RM60200-2CR 1 12 131 5.2 70 16 6 3 3.0 200 7. 32 1.2 32 1.2 271 10.7 285 11.2 ALLEN KEY #:3/8"(10.0MM) 17 7.1 8 3.5 2 46 1 67 2 67 2 284 11.2 WITH OPTIONAL COVER 45 1 RM60200-3CR 18

Class R 2V and 600V modular ferrule and Technical Data 1048 Dimensions; 400A, 600V Class R block - in (mm) ALLEN KEY #:1/2" 156 80 21 6.2 3.2 ALLEN KEY #:1/2" 156 80 6.2 3.2 8 21 185 7 2 206 8.1 1 16 206 8.1 42 1 16 71 2 2 44 44 71 2 RM60400-1CR RM60400-2CR 277 10. 156 80 6.2 3.2 21 42 121 4 317 12.5 105 4.1 330 13.0 ALLEN KEY #:1/2" 42 113 4.5 116 4 206 8.1 1 16 334 13.2 WITH OPTIONAL COVER 71 2 2 2 44 RM60400-3CR 1

Technical Data 1048 Class R 2V and 600V modular ferrule and Dimensions; 600A, 600V Class R block - in (mm) 184 7.2 1 25 1.0 2. 184 7.2 25 1 1.0 8 2. 1 ALLEN KEY #: 3/8"(10.0MM) 125 4. 1 16 231.1 ALLEN KEY #: 3/8"(10.0MM) 2. 1 16 231.1 2. 2 78 3.1 7 3 2 43 43 78 3.1 RM60600-1CR 2 RM60600-2CR 184 7.2 1 25 1.0 2. 1 6.0 1 5 366 14.4 ALLEN KEY #: 3/8"(10.0MM) 1 37 14. 2. 13 5.5 142 5 78 3.1 1 16 2 2 7 3 231.1 7 3 2 2. 383 15.1 WITH OPTIONAL COVER 43 RM60600-3CR 20

Class R 2V and 600V modular ferrule and Technical Data 1048 21

Technical Data 1048 Class R 2V and 600V modular ferrule and The only controlled copy of this data sheet is the electronic read-only version located on the Eaton network drive. All other copies of this document are by definition uncontrolled. This bulletin is intended to clearly present comprehensive product data and provide technical information that will help the end user with design applications. Eaton reserves the right, without notice, to change design or construction of any products and to discontinue or limit distribution of any products. Eaton also reserves the right to change or update, without notice, any technical information contained in this bulletin. Once a product has been selected, it should be tested by the user in all possible applications. Eaton 1000 Eaton Boulevard Cleveland, OH 44122 Eaton.com Bussmann Division 114 Old State Road Ellisville, MO 63021 United States 2016 Eaton All Rights Reserved Printed in USA Publication No. 1048 BU-MC16XXX February 2016 Eaton and Bussmann are valuable trademarks of Eaton in the U.S. and other countries. You are not permitted to use the Eaton trademarks without prior written consent of Eaton. For Eaton s Bussmann series product information, call 1-855-287-7626 or visit: Follow us on social media to get the latest product and support information.