UL TEST REPORT AND PROCEDURE

Similar documents
UL TEST REPORT AND PROCEDURE

UL TEST REPORT AND PROCEDURE

UL TEST REPORT AND PROCEDURE

UL TEST REPORT AND PROCEDURE

COVER PAGE FOR TEST REPORT

File E Project 07CA Issued: August 29, 2007 Revised: June 22, 2015 REPORT *COMPONENT - POWER SUPPLIES, INFORMATION TECHNOLOGY EQUIPMENT

UL TEST REPORT AND PROCEDURE

UL TEST REPORT AND PROCEDURE

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements

TEST REPORT IEC Information technology equipment - Safety - Part 1: General requirements

TEST REPORT IEC Information technology equipment - Safety - Part 1: General requirements

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements

UL TEST REPORT AND PROCEDURE

TEST REPORT IEC Information technology equipment - Safety - Part 1: General requirements

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements

TEST REPORT IEC Information technology equipment - Safety - Part 1: General requirements

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements

COVER PAGE FOR TEST REPORT

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements

COVER PAGE FOR TEST REPORT

File E Project 02ME CORD CONNECTED CLASS 2 POWER UNITS. Globtek Inc. Northvale, NJ

COVER PAGE FOR TEST REPORT

TEST REPORT IEC Part 1: General requirements for basic safety and essential performance

E A51-UL 2014-September-02 XP POWER L L C SUITE E DYER RD SANTA ANA CA 92705

File E Project 01ME June 15, 2001 REPORT POWER SUPPLIES, INFORMATION TECHNOLOGY EQUIPMENT, INCLUDING ELECTRICAL BUSINESS EQUIPMENT

COVER PAGE FOR TEST REPORT

TEST REPORT IEC Part 1: General requirements for basic safety and essential performance

Certificate of Compliance

File E Project 01ME August 14, 2001 REPORT

File E Project 92ME February 6, 1992 REPORT COMPONENT - POWER SUPPLIES. For Use In INFORMATION TECHNOLOGY EQUIPMENT, INCLUDING ELECTRICAL

Applicant s address. Identification: (Model No.) Serial No.: Lab Name Lab address

Certificate of Compliance

Max. Input Power (W) Inrush Current (A pk /µs)

File E Project 00SC October 9, 2000 REPORT POWER SUPPLIES, INFORMATION TECHNOLOGY EQUIPMENT, INCLUDING ELECTRICAL BUSINESS EQUIPMENT

File E Project 00SC June 22, 2000 REPORT POWER SUPPLY ADAPTER INFORMATION TECHNOLOGY EQUIPMENT, INCLUDING ELECTRICAL BUSINESS EQUIPMENT

FR circuit breaker - hydraulic magnetic,

Certificate of Compliance

C E R T I F I C A T E O F C O M P L I A N C E

COVER PAGE FOR TEST REPORT

Certificate of Compliance

INSTALLATION AND OPERATING INSTRUCTIONS OF THE INTERNATIONAL ISOBOX SERIES ISOLATION TRANSFORMERS.

FR circuit breaker - hydraulic magnetic, railway, very high current. Datasheet

for the use of SIQ Type Approved certification mark 51-SIQ BG 004/130 Project file: C DIN Rail Power Supply

SPECIFIC TECHNICAL CRITERIA

COVER PAGE FOR TEST REPORT

File E47705 Project 97ME August 21, 1997 REPORT. MOTOR CONTROLLERS, MANUAL Amberg, FED REP Germany

Information technology equipment Safety Part 1: General requirements

Miniature Relay PT 2 pole 12 A, 3 pole 10 A or 4 pole 6 A DC- or AC-coil

TC-500PD8. Switching Power Supply ( PS2 A T X 500W 8 0+ ) SPECIFICATION. Revision: 2.0

Presented to the IAPMO Standards Review Committee on December 9, 2013

RECHARGEABLE LITHIUM-ION BATTERIES FOR SYSTEMS

File E Vol 1 Auth. Page 1 Issued: Revised: Manufacturer: SEE ADDENDUM FOR MANUFACTURER LOCATIONS

BATTERY CHARGERS NO. 3

Product Cross Reference

UL TEST REPORT AND PROCEDURE

Three-phase 200 V series: FRN0025 to 0060C2S-2U Three-phase 400 V series: FRN0013 to 0030C2S-4U

Printed Board Cemented Joint Program Based on UL/IEC and IEC

Load (2) Single or Dual

Max. Input Power (W) Input Current. Inrush 347V Vin 60/ C. 480V Vac Vin 85 / 115. Dimming Method.

RUC industrial relays of small dimensions

Features. LED Driver. RACT09 9 Watt. TRIAC Dimmable. Single Output RACT09- AC/DC Converter

File E63614 Project 01SC January 10, 2002 REPORT COMPONENT - MOTOR CONTROLLERS, MAGNETIC. Fujitsu Takamisawa Component Ltd.

1 Phase electronic contactor (SC 1)

M-SERIES MAGNITUDE LIGHTING MAGNETIC DIMMABLE CLASS 2 LED DRIVER QUICK SPECS ENCLOSURE DETAILS

INSTALLATION AND OPERATING INSTRUCTIONS OF THE INTERNATIONAL ISOBOX SERIES ISOLATION TRANSFORMERS.

SST-ST75F-ESS The essential silver standard

AR circuit breaker - Hydraulic magnetic,

YCCS Zone/Bypass Damper Assembly

UL TEST REPORT AND PROCEDURE

INSTRUCTION MANUAL MODEL PS VDC POWER SUPPLY

DART Charger Product Description, Information and Specification

GB/T Translated English of Chinese Standard: GB/T Translated by:

Certificate of Compliance

PDR circuit breaker - Ground fault Datasheet

881WP. Type List. Ordering Information 881 WP1-1A C - - C Basic series designation 4. C -- Contact material AgNi

File E Project 02NK REPORT COMPONENT - POWER SUPPLIES, INFORMATION TECHNOLOGY EQUIPMENT INCLUDING ELECTRICAL BUSINESS EQUIPMENT

Certificate of Compliance

Rated load current (resistive load) SRP. Min. 0.9 (max. 25 of difference between voltage phase and current phase)

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements

Low Voltage Directive Report

RUZ- _/_ Protection (3) Isolation Option (4)

Certificate of Compliance

UL TEST REPORT AND PROCEDURE

Safety Relay Unit. Ordering Information. Ideal for Safety Door and Emergency Stop Switch Circuits for Machines in European Countries

S4562C 1085 COMBI BOARD APPLICATION. Contents PRODUCT HANDBOOK. General

Function Relays, Interfaces and Converters

SPECIFICATION FSP350-60APN(85) Bronze. (Erp2013) DATE:MAY, 14, 2013 表單編號 :7000P Page1

AF series contactors (9 2650)

IFICA IO T ON SHEET FOR LED PORTABLE LUMINAIRE WITH EMERGENCY FUNCTION EXL 660P

File E Vol. 1 Sec. 125 Page 1 Issued: and Report Revised:

Contact data Number and type of contacts Contact material Rated / max. switching voltage Min. switching voltage

Models. Output current max.* Output Power max. Low Line : VAC High Line: VAC 24 VDC / 12 A 240 W. Back up battery

Coil Data Nominal Current MA Nominal VA Sealed Single Pole Normally Open (SPNO) White Rodgers Q

T2111EN Technical Data Sheet Rev 04 Air Cooled Rectifier Bridge MVR : 690V, 1600Adc

moog MSD Servo Drive UL-Certification MSD Servo Drive product range

Transcription:

Issue Date: 2016-04-08 Page 1 of 24 Report Reference # E186249-A263-UL UL TEST REPORT AND PROCEDURE Standard: Certification Type: CCN: Product: Model: Rating: UL 60950-1, 2nd Edition, 2014-10-14 (Information Technology Equipment - Safety - Part 1: General Requirements) CAN/CSA C22.2 No. 60950-1-07, 2nd Edition, 2014-10 (Information Technology Equipment - Safety - Part 1: General Requirements) Component Recognition QQGQ2, QQGQ8 (Power Supplies for Information Technology Equipment Including Electrical Business Equipment) Switching power supply LCM600Q, LCM600W, LCM600Q-T-401, LCM600L, LCM600U, LCM600W-T-401, LCM600Q-T-405, LCM600Q-T-407, LCM600Q-N, LCM600N, LCM600Q-4-404, LCM600L-N, LCM600Q-T-409, LCM600U-T-404, LCM600W-N AC input: 100-240 Vac, 8.5 A Max., 50/60 Hz Models LCM600Q, LCM600Q-T-405, LCM600Q-N, LCM600Q-4-404: DC-outputs: +24 Vdc, 27.0 A Max., 600 W max; +5.0 Vsb, 2.0 A Max. Models LCM600W, LCM600W-N & LCM600W-T-401: DC-outputs: +48 Vdc, 13.0 A Max., 600 W max; +5.0 Vsb, 2.0 A Max. Model LCM600Q-T-401: DC-outputs: +24 Vdc, 18.75 A Max., 450 W max; +5.0 Vsb, 2.0 A Max. Model LCM600L, LCM600L-N: DC-outputs: +12 Vdc, 52.0 A Max., 600 W max; +5.0 Vsb, 2.0 A Max. Model LCM600U: DC-outputs: +36 Vdc, 18.0 A Max., 600 W max; +5.0 Vsb, 2.0 A Max. Model LCM600Q-T-407: DC-output: +24V, 23.0A max, 500W Max Model LCM600N: DC-outputs: +15 Vdc, 44.0 A Max., 600 W max; +5.0 Vsb, 2.0 A Max Model LCM600Q-T-409: DC-outputs: +24 Vdc, 27.0 A Max., 600 W max Model LCM600U-T-404: DC-output: +40 Vdc, 15.0 A Max., 600 W max Output derates at 2.5% per deg C from 50 degc to 70 deg C Applicant Name and Address: ASTEC INTERNATIONAL LTD Copyright 2016

Issue Date: 2016-04-08 Page 2 of 24 Report Reference # E186249-A263-UL 16TH FL LU PLAZA 2 WING YIP ST KWUN TONG KOWLOON HONG KONG This is to certify that representative samples of the products covered by this Test Report have been investigated in accordance with the above referenced Standards. The products have been found to comply with the requirements covering the category and the products are judged to be eligible for Follow-Up Service under the indicated Test Procedure. The manufacturer is authorized to use the UL Mark on such products which comply with this Test Report and any other applicable requirements of UL LLC ('UL') in accordance with the Follow- Up Service Agreement. Only those products which properly bear the UL Mark are considered as being covered by UL's Follow-Up Service under the indicated Test Procedure. The applicant is authorized to reproduce the referenced Test Report provided it is reproduced in its entirety. UL authorizes the applicant to reproduce the latest pages of the referenced Test Report consisting of the first page of the Specific Technical Criteria through to the end of the Conditions of Acceptability. Any information and documentation involving UL Mark services are provided on behalf of UL LLC (UL) or any authorized licensee of UL. Prepared by: Leung Chi Wah Reviewed by: Paul Wan Copyright 2016

Issue Date: 2016-04-08 Page 3 of 24 Report Reference # E186249-A263-UL Supporting Documentation The following documents located at the beginning of this Procedure supplement the requirements of this Test Report: A. Authorization - The Authorization page may include additional Factory Identification Code markings. B. Generic Inspection Instructions - i. Part AC details important information which may be applicable to products covered by this Procedure. Products described in this Test Report must comply with any applicable items listed unless otherwise stated in the body of this Test Report. ii. Part AE details any requirements which may be applicable to all products covered by this Procedure. Products described in this Test Report must comply with any applicable items listed unless otherwise stated in the body of each Test Report. iii. Part AF details the requirements for the UL Certification Mark which is not controlled by the technical standard used to investigate these products. Products are permitted to bear only the Certification Mark(s) corresponding to the countries for which it is certified, as indicated in each Test Report.

Issue Date: 2016-04-08 Page 4 of 24 Report Reference # E186249-A263-UL Product Description The equipment is a switching power supply, intended for building in as a component used in information technology equipment which employs isolating transformers. Reinforced insulation is provided between primary and secondary. Basic insulation is provided between primary and PE (Protective Earth). Model Differences Model LCM600W is identical to model LCM600Q except Output rating, Transformer T801 and PWB Layout. Model LCM600Q-T-401 is identical to Model LCM600Q except different output rating and alternate Fan. Model LCM600L is identical to Model LCM600Q, except for output rating, transformer (T801), choke(l302) and insulator. Model LCM600U is identical to Model LCM600Q, except for output rating, transformer (T801), choke(l302) and insulator. Model LCM600W-T-401 is identical to Model LCM600W except for model designation and 4 output terminals provided. Model LCM600Q-T-405 is identical to Model LCM600Q except for model designation. Model LCM600Q-N is identical to Model LCM600Q except for model designation and Fan. Model LCM600Q-T-407 is identical to Model LCM600Q except for model designation and Fan filter. Model LCM600N is identical to Model LCM600Q, except for output rating, transformer (T801), choke(l302) and insulator. Model LCM600Q-4-404 is identical to Model LCM600Q-N, except for input cable assembly. Model LCM600L-N is identical to Model LCM600L except for model designation, and fan used and alternate insulator is for use across the whole series. Model LCM600Q-T-409 is identical to Model LCM600Q except for model designation and it has no +5.0 Vsb output rating. Additional tests were conducted for customer requirement only. Model LCM600U-T-404 is identical to Model LCM600U except for model designation, output rating, input wiring assembly and PCB layout to meet the new creepage and clearance required by the customer which are higher than the safety requirement. Model LCM600W-N is identical to Model LCM600W except for model designation and alternate Fan. Technical Considerations Equipment mobility : for building-in Connection to the mains : pluggable A Operating condition : continuous Access location : N/A Over voltage category (OVC) : OVC II Mains supply tolerance (%) or absolute mains supply values : +10%, -10% Tested for IT power systems : No IT testing, phase-phase voltage (V) : N/A

Issue Date: 2016-04-08 Page 5 of 24 Report Reference # E186249-A263-UL Class of equipment : Class I (earthed) Considered current rating of protective device as part of the building installation (A) : Rated Input 8.5 A Max. Pollution degree (PD) : PD 2 IP protection class : IP X0 Altitude of operation (m) : 5000m Altitude of test laboratory (m) : less than 2000 meters Mass of equipment (kg) : <18 The creepage and clearance distances have additionally been assessed for suitability up to 5000m. The equipment is a component level power supply intended for use in Class I applications The product was submitted and evaluated for use at the maximum ambient temperature (Tma) permitted by the manufacturer s specification of: 50 degree C and up to 70 degree C at derated power The means of connection to the mains supply is: Pluggable A The product is intended for use on the following power systems: TN The equipment disconnect device is considered to be: Appliance inlet The product was investigated to the following additional standards: EN 60950-1:2006+ A11:2009 + A1:2010 +A12:2011+A2: 2013. (which includes all European national differences, including those specified in this test report). For Models LCM600Q and LCM600Q-4-404: CSA C22.2 NO. 61010-1 SAFETY REQUIREMENTS FOR ELECTRICAL EQUIPMENT FOR MEASUREMENT, CONTROL, AND LABORATORY USE - PART 1: GENERAL REQUIREMENTS - Edition 2 - Revision Date 2008/10/01 UL 61010-1 SAFETY REQUIREMENTS FOR ELECTRICAL EQUIPMENT FOR MEASUREMENT, CONTROL, AND LABORATORY USE - PART 1: GENERAL REQUIREMENTS - Edition 2 - Revision Date 2008/10/28 The following accessible locations (with circuit/schematic designation) are within a limited current circuit: Sec. pin of C137 The following are available from the Applicant upon request: Installation (Safety) Instructions / Manual Model LCM600Q was tested at inhibit mode (fan off/ stop condition) at 50 C ambient temperature. Engineering Conditions of Acceptability For use only in or with complete equipment where the acceptability of the combination is determined by UL LLC. When installed in an end-product, consideration must be given to the following: The secondary output connector has not been evaluated for field connections. The power supply has been evaluated for use in Class 1 equipment as defined in UL 60950-1 Second edition and CAN/CSA C22.2 No. 60950-1-07. An additional evaluation shall be made if the power supply is intended for use in other than Class 1 equipment. No energy hazard (below 240VA) exists at the PSU outputs in the removed condition. Connection to the supply: Pluggable equipment type A. With non-detachable input cord in end system. The disconnection from the line should be considered in the end system. The equipment was not evaluated for system mounting. When installed in the end system, proper evaluation should be considered. For Model LCM600Q: Additional evaluation has been considered for the +24V +/- 20% Output voltage adjustability limited to the following combined conditions: maximum allowed 27A output

Issue Date: 2016-04-08 Page 6 of 24 Report Reference # E186249-A263-UL current and 600W output power. For Model LCM600W: Additional evaluation has been considered for the +48V +/- 20% Output voltage adjustability limited to the following combined conditions: maximum allowed 13A output current and 600W output power. For Model LCM600L: Additional evaluation has been considered for the +12V +/- 20% Output voltage adjustability limited to the following combined conditions: maximum allowed 52A output current and 600W output power. For Model LCM600U: Additional evaluation has been considered for the +36V +/- 20% Output voltage adjustability limited to the following combined conditions: maximum allowed 18A output current and 600W output power For Model LCM600N: Additional evaluation has been considered for the +15.0V +30 % - 20% Output voltage adjustability limited to the following combined conditions: maximum allowed 44A output current and 600W output power The following secondary output circuits are at hazardous energy levels: +24Vdc (Models LCM600Q, LCM600Q-4-404, LCM600Q-T-401, LCM600Q-T-405, LCM600Q-T-407, LCM600Q-N and LCM600Q-T-409), +48Vdc (Models LCM600W, LCM600W-N and LCM600W-T-401), +12Vdc (Model LCM600L and LCM600L-N), +36Vdc (Model LCM600U), +15Vdc (Model LCM600N), +40Vdc (Model LCM600U-T-404) The following secondary output circuits are at non-hazardous energy levels: +5Vsb The following Production-Line tests are conducted for this product: Earthing Continuity, Electric Strength The end-product Electric Strength Test is to be based upon a maximum working voltage of: Primary- SELV: 422.7 Vrms, 689 Vpk Primary-Earthed Dead Metal: 414.9 Vrms, 689 Vpk. For model LCM600U, Primary-SELV: 397.7Vrms, -990 Vpk, Primary-Earthed Dead Metal: 398.0 Vrms, 663 Vpk The following secondary output circuits are SELV: +24Vdc (Models LCM600Q, LCM600Q-4-404, LCM600Q-T-401, LCM600Q-T-405, LCM600Q-T-407, LCM600Q-N and LCM600Q-T-409), +48Vdc (Models LCM600W, LCM600W-N and LCM600W-T-401), +12Vdc (Model LCM600L and LCM600L- N), +36Vdc (Model LCM600U), +15Vdc (Model LCM600N), +40Vdc (Model LCM600U-T-404) and +5Vsb (all models except for LCM600Q-T-409 and LCM600U-T-404) The maximum investigated branch circuit rating is: 30 A The following secondary output circuits are Limited Current Circuits: Sec. pin of C137 The equipment is suitable for direct connection to: AC mains supply The following end-product enclosures are required: Mechanical, Fire, Electrical The power supply terminals and/or connectors are: Not investigated for field wiring The investigated Pollution Degree is: 2 Proper bonding to the end-product main protective earthing termination is: Required An investigation of the protective bonding terminals has: Been conducted The following magnetic devices (e.g. transformers or inductor) are provided with an OBJY2 insulation system with the indicated rating greater than Class A (105 C): T801, T101, T302 (Class F)