I n d e K l i m a M i l j ø A / S IndeKlimaMiljø A/S, or just, takes advantage in many years of experience as well internally as with our partners and suppliers of solutions for the ventilation business. Hence has the dynamics of the small organization and the competences of the larger companies., was founded in 3, and acquired by the present owners at the beginning of 8. The starting point is everybody s demand for a comfortable indoor climate and our need for a healthy environment. From this point new products and methods are developed in close collaboration with architects, engineers and installers to form overall solutions based on the expertise and products from. aims for total solutions, and we therefore appreciate a close dialog with the costumer and engineering company regarding the best possible solution to the actual job.
Content Subject Page Fresh air units and accessories Comfort 3 Comfort 1 7 Entra 7e 1 Entra 1i 13 Entra i 16 Accessories for fresh air units CID 19 CID 31 Grilles 1
Comfort 3 Description Comfort 3 is a fresh air unit complete with heater, thermostat and filter. Comfort 3 is ideal for tempering of replacement air in rooms with extraction of used air. Filter Comfort 3 s filter is conveniently located immediately behind the front. The filter ensures easy and uncomplicated cleaning or replacement. The standard filterer is made of easy cleanable polyester foam. Allergic filter of filter grade EU7 is available as option. Air intake Comfort 3 is delivered with an outside grille as standard, which is developed for extremely low air resistance. The grille protects efficiently against rain etc. Wall duct with dampers The wall ducting is round with an internal diameter of Ø. The duct is equipped with an aerodynamic and self-regulating damper. At a pressure drop of around. pa. the damper startsclosing to prevent over ventilation. Silencing Under normal conditions the Comfort 3 offers sufficient damping. Supplemental damping can be achieved with an integrated silencer built into the wall duct. Heating coil Comfort 3 is built around a heating element. A special system protects it against damages due to freezing the element. The heating element is built in a way to ensure a uniform distribution of heat across the element. This means fresh air without draft. Counter damper Comfort 3 is equipped with an efficient counter damper which prevents room air to pass backwards out through the unit due to negative pressure on the rear side of the building. Along with the wind damper this counter damper is very efficient. The counter damper is purely mechanical operated with a closing pressure of only, Pa. Temperature control Behind the front an easy accessible thermostat valve is placed. The temperature of the intake air is controlled automatically with a sensing element in the air stream. The optimum function is achieved when the fresh air is app. C below desired room temperature. Factory setting is 18 C. In situations with small loads, low volumes etc., the supply temperature may vary. Maintenance Comfort 3 can be opened with special tooling, where after access to filter, thermostat, heating element and damper is granted. Technical data Air capacity: Distribution length: Heating capacity: Water connection: Water connection: max. 3 l/s (16 m3/h), m/s at 1, m 1,, kw x 3/8" internal. max.,3 bar diff. pressure Subject to changes of
Performance data Air capacity Mounting on inner wall The centre of the Ø1-wall duct hole at the inner side of the wall, must be located at least 33 mm above the floor. The armature front (B x H = 31 x 36) is bigger than the wall duct and covers the valves and thermostat. Hidden pipe connection When using hidden connection, the distances between holes and the pipe connections are very important. (C-C 13 mm). Visible pipe connection When using visible connections the pipes are placed 6 mm and 1 mm to the left of the centre line. Connections are ⅜ thread. The curves apply to Comfort 3 with PPI standard filter and EU 7 filter. Wall duct Silencerer Winddamper Grille Heating element with counter damper Armature front Frame mounted/removed by means of finger screws The front can be removed when locking spring is released through hole at the bottom using thin pin or needle Distance between wind damper and silencer to ensure free movement of damper blades When finger screw is loosened the heating element can be tilted for easy cleaning or mounting of silencer Subject to changes of
Dimensioning Diagram 1A Temperatures 7/ C t v=3 C Diagram Temperature increase P v q l t l Diagram 1B Temperatures / C t v=1 C Diagram 3 Waterflow P v t v q v Diagram 1C Temperatures 9/7 C t v= C Diagram Pressuredrop q v P v Designations P v= Heating power (KW) T u= Outside temperature ( C ) t v= Water temperature ( C ) t l= Air temperature ( C ) t v= Temperature diff. water ( C ) t l= Temperature diff. air ( C ) q v= Waterflow (l/s) q l= Air flow (l/s) P v= Pressuredrop water (kpa) P l= Pressuredrop air (kpa) Example Ventilation demand 3 l/s Outside temperature -1 C Supply/return temperatures 7/ C From this you get heating power, air temperature and pressure drop. Solution: Diagram 1A : Heating power is 1, kw at 3 l/s Diagram : With 1, kw and 3 l/s you get delta t 1 38 C Supply air temperature = -1 + 38 = 6 C Diagram 3 : With 1, kw and temperature diff. of 38 C (7/ C ) the water flow is =,1 l/s Diagram : Pressuredrop is 1 kpa at a flow of,1 l/s Subject to changes 6 of
Comfort 1 Description Comfort 1 is a fresh air unit complete with heater, thermostat and filter. Comfort 1 is ideal for tempering of replacement air in rooms with extraction of used air. Filter Comfort 1 s filter is located behind the heating coil. The filter ensures easy and uncomplicated cleaning or replacement. The standard filterer is made of easy cleanable polyester foam. Allergic filter of filter grade EU7 is available as option. Air intake Comfort 1 is delivered with an outside grille as standard, which is developed for extremely low air resistance. The grille protects efficiently against rain etc. Wall duct with dampers The wall ducting is round with an internal diameter of Ø31. The duct is equipped with an aerodynamic and selfregulating damper. At a pressure difference of around. pa. the damper starts closing to prevent over ventilation. Silencing Under normal conditions the Comfort 1 offers sufficient damping. Supplemental damping can be achieved with an integrated silencer built into the wall duct.. Heating coil Comfort 1 is built around a heating element. A special system protects it against damages due to freezing the element. The heating element is built in a way to ensure a uniform distribution of heat across the element. This means fresh air without draft. Counter damper Comfort 1 is equipped with an efficient counter damper which prevents room air to pass backwards out through the unit due to negative pressure on the rear side of the building. Along with the wind damper this counter damper is very efficient. The counter damper is purely mechanical operated with a closing pressure of only, Pa. Temperature control Behind the front an easy accessible thermostat valve is placed. The temperature of the intake air is controlled automatically with a sensing element in the air stream. The optimum function is achieved when the fresh air is app. C below desired room temperature. Factory setting is 18 C. In situations with small loads, low volumes etc., the supply temperature may vary. Maintenance Comfort 1 can be opened with special tooling, where after access to filter, thermostat, heating element and damper is granted. Technical data Air capacity: Distribution length: Heating capacity: Water connection: Water connection: max. 1 l/s (36 m3/h), m/s at 1, m,, kw x 3/8" internal. max.,3 bar diff. pressure Subject to changes 7 of
Performance data Air capacity (Pa) 6,,, 3,, 1, Std. [Pa] EU7 [Pa] Mounting on inner wall The centre of the Ø3-wall duct hole at the inner side of the wall, must be located at least. 98 mm above the floor. The armature front (B x H = 7 x ) is bigger than the wall duct and covers the valves and thermostat. Hidden pipe connection When using hidden connection, the distances between holes and the pipe connections are very important. (C-C 13 mm). Visible pipe connection When using visible connections the pipes are placed 6 mm and 1 mm to the left of the centre line. Connections are ⅜ thread., 7 1 1 The curves apply to Comfort 1 with (l/s) PPI standard filter and EU 7 filter. Wall duct Silencer Winddamper Grille Heating element with counter damper Armature front Frame mounted/removed by means of screw Distance between wind damper and silencer to ensure free movement of damper blades When finger screw is loosened the heating element can be tilted for easy cleaning or mounting of silencer The front can be removed when locking spring is released through hole at the bottom Subject to changes 8 of
Dimensioning Diagram 1A Temperatures 7/ C t v=3 C Diagram Temperature increase P v q l t l t l ( C) 6 7 1 Diagram 1B Temperatures / C t v=1 C 3 1 6 8 1 7 6 3 1 6 8 1 q l (l/s) Diagram 1C Temperatures 9/7 C t v= C Designations P v= Heating power (KW) T u= Outside temperature ( C ) t v= Water temperature ( C ) t l= Air temperature ( C ) t v= Temperature diff. water ( C ) t l= Temperature diff. air ( C ) q v= Waterflow (l/s) q l= Air flow (l/s) P v= Pressuredrop water (kpa) P l= Pressuredrop air (kpa) q l (l/s) -1-1 -1-1 -1-1 PV (kw) 1 3 6 Diagram 3 Waterflow P v t v q v 3 1 3 1 qv (l/s),,,1,1, ΔPv(kpa) 1 1 1 Diagram Pressuredrop q v P v tv ( C) qv (l/s),,,6,8,1 Example Ventilation demand 1 l/s Outside temperature -1 C Supply/return temperatures 7/ C From this you get heating power, air temperature and pressure drop. Solution: Diagram 1A : Heating power is,1 kw at 1 l/s Diagram : With,1 kw and 1 l/s you get delta t 1 3 C Supply air temperature = -1 + 3 = C Diagram 3 : With,1 kw and temperature diff. of 3 C (7/ C ) the water flow is =,3 l/s Diagram : Pressuredrop is, kpa at a flow of,3 l/s Subject to changes 9 of
Entra 7e Description Entra 7e is a freshair unit complete with heating coil, electronic control and filter. Silencing Under normal conditions the Entra 7e offers sufficient damping. Supplemental damping can be achieved with an integrated silencer built into the wall duct. Heating coil Entra 7e is built around a heating element. A special system protects it against damages due to freezing the element. The heating element is built in a way to ensure a uniform distribution of heat across the element. This means fresh air without draft. Entra 7e is ideal for tempering of replacement air in rooms with extraction of used air. Filter Entra 7e s filter is conveniently located immediately behind the front. The filter ensures easy and uncomplicated cleaning or replacement. The standard filterer is made of easy cleanable polyester foam. Air intake Entra 7e is delivered with an outside grille as standard, which is developed for extremely low air resistance. The grille protects efficiently against rain etc. Wall duct with dampers The wall ducting is round with an internal diameter of Inner diameter Ø. The duct is equipped With et motor driven damper acting as a regulating damper and closing damper. The controller adjusts the opening in case of low temperature or user input. Counter damper Entra 7e is equipped with an efficient counter damper which prevents room air to pass backwards out through the unit due to negative pressure on the rear side of the building. Along with the wind damper this counter damper is very efficient. The counter damper is purely mechanical operated with a closing pressure of only, Pa. Temperature control Behind the front the control and motor valve is located. The supply temperature is regulated automatically by the motor controlled valve and a sensor in the supply air. The optimum function is achieved when the fresh air is app. C below desired room temperature. In situations with small loads, low volumes etc., the supply temperature may vary. Maintenance Entra 7e can be opened with special tooling, where after access to filter, thermostat, heating element and damper is granted. Technical data Air capacity: max. 7 m3/h Distribution length:, m/s at 1, m Heating capacity: 6, 1, kw Water connection: x 3/8". Water connection: max.,3 bar diff. pressure Subject to changes 1 of
Performance data Air capacity (Pa),,, 3, 3,, Std. [Pa] EU7 [Pa] Hidden pipe connection When using hidden connection, the distances between holes and the pipe connections are very important. (C-C 13 mm). Visible pipe connection When using visible connections the pipes are placed 6 mm and 1 mm to the left of the centre line. Connections are ⅜ thread., 1, 1,,, 7 1 The curves apply to Entra 7e with (m 3 /h) PPI standard filter and EU7 filter. Damper connecting Grille Damper Damper motor Wall duct Control box Filterframe Front Motorvalve Mounting on inner wall The centre of the Ø1-wall duct hole at the inner side of the wall must be located at least. mm above the floor. The armature front (B x H = 6 x 73) is bigger than the wall duct and covers the valves and thermostat. The front can be removed by loosening the screw at the buttom Subject to changes 11 of
Dimensioning Diagram 1A Temperatures 7/ C t v=3 C Diagram Temperature increase P v q l t l 1 1 8 6 6 8 1 1 16 1 8 6 6 8 8 6 8 q l (l/s) Diagram 1B Temperatures / C t v=1 C q l (l/s) Diagram 1C Temperatures 9/7 C t v= C Designations P v= Heating power (KW) T u= Outside temperature ( C ) t v= Water temperature ( C ) t l= Air temperature ( C ) t v= Temperature diff. water ( C ) t l= Temperature diff. air ( C ) q v= Waterflow (l/s) q l= Air flow (m3/h) P v= Pressuredrop water (kpa) P l= Pressuredrop air (kpa) q l (l/s) -1-1 -1-1 -1-1 -1-1 -1 t l ( C) 6 1 1 8 6 1 3 6 3 1 ΔPv(kpa) 3 3 1 1 qv (l/s),,1,1, 1 9 PV (kw) 6 8 1 1 1 16 Diagram 3 Waterflow P v t v q v tv ( C),,1,,3, Diagram Pressuredrop q v P v Example qv (l/s) Ventilation demand 7 m3/h Outside temperature -1 C Supply/return temperatures 7/ C From this you get heating power, air temperature and pressure drop. Solution: Diagram 1A : Heating power is 8,3 kw at l/s Diagram : With 8,3 kw and 7m3/h you get delta t 1 33 C Supply air temperature = -1 + 33 = 1 C Diagram 3 : With 8,3 kw and temperature diff. of 3 C (7/ C ) the water flow is =,7 l/s Diagram : Pressuredrop is 1 kpa at a flow of,7 l/s Subject to changes 1 of
Entra 1i Description Entra 1i is a fresh air unit complete with heater, thermostat and filter, for build in. Silencing Under normal conditions the Entra 1i offers sufficient damping. Supplemental damping can be achieved with an integrated silencer built into the wall duct. Heating coil Entra 1i is built around a heating element. A special system protects it against damages due to freezing the element. The heating element is built in a way to ensure a uniform distribution of heat across the element. This means fresh air without draft. Entra 1i is ideal for tempering of replacement air in rooms with extraction of used air. Filter Entra 1i s filter is conveniently located immediately behind the front. The filter ensures easy and uncomplicated cleaning or replacement. The standard filterer is made of easy cleanable polyester foam. Air intake Entra 1i is delivered with an outside grille as standard, which is developed for extremely low air resistance. The grille protects efficiently against rain etc. Wall duct with dampers Wall duct in round shape. Inner diameter Ø. The duct is equipped With a winddamper which acts as a regulating damper. If the airflow across the damper is too high, the opening is reduced to ensure correct supply temperature. At a pressure drop of around. pa. the damper starts closing to prevent over ventilation. Counter damper Entra 1i is equipped with an efficient counter damper which prevents room air to pass backwards out through the unit due to negative pressure on the rear side of the building. Along with the wind damper this counter damper is very efficient. The counter damper is purely mechanical operated with a closing pressure of only, Pa. Temperature control Behind the front the thermostat and valve is placed easily accessible. The temperature of the supply air is regulated automatically by a sensor in the airstream. The optimum function is achieved when the fresh air is app. C below desired room temperature. In situations with small loads, low volumes etc., the supply temperature may vary. Maintenance Entra 1i kan can be opened with special tooling, where after access to filter, thermostat, heating element and damper is granted. Technical data Air capacity: max. 1 m3/h Distribution length:, m/s at 1, m Heating capacity:,9,3 kw Water connection: x 3/8". Water connection: max.,3 bar diff. pressure Subject to changes 13 of
Performance data Air capacity (Pa) 6,, Std. [Pa] EU7 [Pa] Pipe connection When connecting, the distances between holes and the pipe connections are very important. (C-C 13 mm). The pipes are to be placed mm to the right and 113 mm to the left of the centre line. Distances from the wall to the pipes are 9, mm. Connections are ⅜ thread., 3,, 1, Wall duct Grille Wind damper Front Thermostat, 1 3 (m3/h) The curves apply to Entra 1i with PPI standard filter and EU7 filter. The front can be removed by loosening the screw at the buttom Mounting on inner wall The centre of the Ø-wall duct hole at the inner side of the wall, must be located at least. 3 mm above the floor. The armature front (B x H = 3 x 397) is bigger than the wall duct and covers the valves and thermostat. Subject to changes 1 of
Dimensioning Diagram 1A Temperatures 7/ C t v=3 C Diagram Temperature increase P v q l t l -1-1 -1 t l ( C) 6 7 1 1 1 1 ql (m3/h) 3 6 9 1 1 P V (kw) 1 3 Diagram 1B Temperatures / C t v=1 C Diagram 3 Waterflow P v t v q v, 1, -1-1 -1 P v (kw) 3 1 t v ( C) 1 1, q l (m3/h) 3 6 9 1 1 1 q v (l/s),,,,6 Diagram 1C Temperatures 9/7 C t v= C 3, 1, 1, q l (m3/h) 3 6 9 1 1 Designations P v= Heating power (KW) T u= Outside temperature ( C ) t v= Water temperature ( C ) t l= Air temperature ( C ) t v= Temperature diff. water ( C ) t l= Temperature diff. air ( C ) q v= Waterflow (l/s) q l= Air flow (m3/h) P v= Pressuredrop water (kpa) P l= Pressuredrop air (kpa) -1-1 -1 Diagram Pressuredrop q v P v ΔPv(kpa) 1 1 1 8 6 Example qv (l/s),1,3,,6 Ventilation demand 1 m3/h Outside temperature -1 C Supply/return temperatures 7/ C From this you get heating power, air temperature and pressure drop. Solution: Diagram 1A : Heating power is 1,7 kw at 1 m3/h Diagram : With 1,7 kw and 1 m3/h you get delta t 1 38 C Supply air temperature = -1 + 38 = 6 C Diagram 3 : With 1,7 kw and temperature diff. of 3 C (7/ C ) the water flow is =,1 l/s Diagram : Pressuredrop is 1 kpa at a flow of,1 l/s Subject to changes 1 of
Entra i Description Entra i is a fresh air unit complete with heater, thermostat and filter, for build in. Silencing Under normal conditions the Entra i offers sufficient damping. Supplemental damping can be achieved with an integrated silencer built into the wall duct. Heating coil Entra i is built around a heating element. A special system protects it against damages due to freezing the element. The heating element is built in a way to ensure a uniform distribution of heat across the element. This means fresh air without draft. Entra i is ideal for tempering of replacement air in rooms with extraction of used air. Filter Entra i s filter is conveniently located immediately behind the front. The filter ensures easy and uncomplicated cleaning or replacement. The standard filterer is made of easy cleanable polyester foam. Air intake Entra i is delivered with an outside grille as standard, which is developed for extremely low air resistance. The grille protects efficiently against rain etc. Wall duct with dampers Wall duct in round shape. Inner diameter Ø31. The duct is equipped With a winddamper which acts as a regulating damper. If the airflow across the damper is too high, the opening is reduced to ensure correct supply temperature. At a pressure drop of around. pa. the damper starts closing to prevent over ventilation. Counter damper Entra i is equipped with an efficient counter damper which prevents room air to pass backwards out through the unit due to negative pressure on the rear side of the building. Along with the wind damper this counter damper is very efficient. The counter damper is purely mechanical operated with a closing pressure of only, Pa. Temperature control Behind the front the thermostat and valve is placed easily accessible. The temperature of the supply air is regulated automatically by a sensor in the airstream. The optimum function is achieved when the fresh air is app. C below desired room temperature. In situations with small loads, low volumes etc., the supply temperature may vary. Maintenance Entra i can be opened with special tooling, where after access to filter, thermostat, heating element and damper is granted. Technical data Air capacity: max. m3/h Distribution length:, m/s at 1, m Heating capacity:,6,3 kw Water connection: x 3/8". Water connection: max.,3 bar diff. pressure Subject to changes 16 of
Performance data Air capacity (Pa) 6,, Std. [Pa] EU7 [Pa] Pipe connection When connecting, the distances between holes and the pipe connections are very important. (C-C 13 mm). The pipes are to be placed 3mm and 188 mm to the left of the centre line. Distance from the wall to the pipes is 9, mm. Connections are ⅜ thread., 3,, 1, Wall duct Grille Wind damper Front, The curves apply to Entra i with PPI standard filter and EU7 filter. Mounting on inner wall 1 3 (m3/h) The centre of the Ø3-wall duct hole at the inner side of the wall, must be located at least. mm above the floor. The armature front (B x H = x 6) is bigger than the wall duct and covers the valves and thermostat. Thermostat The front can be removed by loosening the screw at the buttom Subject to changes 17 of
Dimensioning Diagram 1A Temperatures 7/ C t v=3 C Diagram Temperature increase P v q l t l -1-1 -1 t l ( C) 6 1 3 3 1 ql (m3/h) 1 3 Diagram 1B Temperatures / C t v=1 C 1 3 6 Diagram 3 Waterflow P v t v q v PV (kw) -1-1 -1 3 1 1 tv ( C) 3 3 1 q l (m3/h) 1 3 Diagram 1C Temperatures 9/7 C t v= C 7 6 3 1 q l (m3/h) 1 3 Designations P v= Heating power (KW) T u= Outside temperature ( C ) t v= Water temperature ( C ) t l= Air temperature ( C ) t v= Temperature diff. water ( C ) t l= Temperature diff. air ( C ) q v= Waterflow (l/s) q l= Air flow (m3/h) P v= Pressuredrop water (kpa) P l= Pressuredrop air (kpa) -1-1 -1 1,,,1,1, Diagram Pressuredrop q v P v ΔPv(kpa) 1 1 Example qv (l/s) qv (l/s),,,6,8,1 Ventilation demand m3/h Outside temperature -1 C Supply/return temperatures 7/ C From this you get heating power, air temperature and pressure drop. Solution: Diagram 1A : Heating power is,3 kw at m3/h Diagram : With,3 kw and m3/h you get delta t 1 33 C Supply air temperature = -1 + 3 = 1 C Diagram 3 : With,3 kw and temperature diff. of 3 C (7/ C ) the water flow is =,3 l/s Diagram : Pressuredrop is kpa at a flow of,3 l/s Subject to changes 18 of
Trykfald (pa) Dæmpning (db) CID Description Silencer for mounting in wall duct for ø mm duct. Damping The sound damping depends on number of units mounted. The models may be combined as needed. 3 Dæmpning 1 The silencer can combined with additional units to achieve maximum damping depending on space available. Space requirements Depending on wall thickness different number of units can be placed. Space requirements = (Wall thickness in mm - 1). Round the measure down till nearest whole number of units. Air resistance Pressure drop across the total damper depends on number of units mounted. 6 Measures Trykfald mm 1 1 3 3 Flow (l/s) 1 mm 1 mm mm 1 - Total damping incl. heating element The total damping is shown in the table below, and depends on number of units mounted. Included is a standard heating element. Konfiguration Vægtet dæmpningstal (db) 1 mm 3 1 mm 3 mm 3 mm 3 Construction 1 3 Frekvens (Hz) Dimension (Diameter): Thickness small model: Thickness large model: ø mm 1 mm 1 mm Front and rear side: Neopren rubber Damper material: Basotech Weight small model:, kg. Weight large model:, kg. 1 mm 1 mm mm mm Subject to changes 19 of
Trykfald (pa) Dæmpning (db) CID 31 Description Silencer for mounting in wall duct for ø31mm duct. Damping The sound damping depends on number of units mounted. The models may be combined as needed. Dæmpning,, 1, The silencer can combined with additional units to achieve maximum damping depending on space available. Space requirements Depending on wall thickness different number of units can be placed. Space requirements = (Wall thickness in mm - 1). Round the measure down till nearest whole number of units. Air resistance Pressure drop across the total damper depends on number of units mounted. 1 8 Measures Trykfald 1mm 1mm mm mm 1 3 6 7 8 9 1 11 Flow (l/s) 1,,, -, Total damping incl. heating element The total damping is shown in the table below, and depends on number of units mounted. Included is a standard heating element. Konfiguration Vægtet dæmpningstal (db) 1mm 3 1mm 31 mm 33 mm 3 Construction 1 3 Frekvens (Hz) Dimension (Diameter): Thickness small model: Thickness large model: ø31 mm 1 mm 1 mm Front and rear side: Neopren rubber Damper material: Basotech Weight small model:,3 kg. Weight large model:, kg. 1mm 1mm mm mm Subject to changes of
Grilles BRYG Rectangular grille. The grille is made of a mounting frame with flanges, water nose and a removable frame with net on the inside. Made from galvanized steel plate as standard. Also available in stainless steel, aluzink, copper or powder coated in any color. BRYV Squared air intake grille. This grill is made with vertical aluminum intake openings with water drains. Water entering with the air is trapped and flows into a drain at the bottom and lead out to the outside. The grille can be delivered with electrical defrosting. The grille is made from aluminum profiles. Also offered with anodized surface or powder painted. BRYI Heavy duty Squared air intake grille. The grille is made from extra heavy materials, specially suited for schoolyards etc. where extra strength is needed. It has deep profiles with dismountable grille parts for easy cleaning and a removable frame with net on the inside. The grille can be delivered with electrical defrosting. Made from galvanized steel plate as standard. Also available in stainless steel or powder coated in any color. BRYJ Squared/circular air intake grille. Standard grille of die cast aluminum. The grille is offered with steel net on the inside. Also available in powder coated in any color. Subject to changes 1 of