Armatures and Heaters

Similar documents
Air Louvers OFAL 300 SERIES

CornerAir. CornerAir. Active chilled beam

DTV, DTH and VVR Roof- and wall fans DTV Roof fan DTH Roof fan VVR Wall fan

Ventilation grilles for installation into walls, sills or rectangular

HRS. Very high efficiency heat recovery units. from 300 to m³/h >90 % WITH HIGH EFFICIENCY HEAT RECOUPERATOR

HEAT-RECOVERY UNITS WITH ENTHALPY/ROTARY HEAT EXCHANGER TECHNICAL MANUAL

DRAFT. Technical Data OPA Ducted Three Phase Packaged Air Conditioners. 47 kw 96 kw

Indirect evaporative air conditioning 100% outside air FACTORY INSTALLATION (CW-160)

Floor diffusers. The art of handling air. Type FB. In aluminium and plastic

Q6SD Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Single Packaged Heat Pump, Single Phase

HRH. High efficiency heat recovery units. from 300 to m³/h >70 % WITH HIGH EFFICIENCY HEAT RECOUPERATOR

PVHRU Max Quiet. Engineering Solutions. Packaged Void Heat Reclaim Unit. Acoustic Testing Laboratory College of Science & Technology

Ceiling swirl diffusers with perforated face plate

ACCESSORIES FOR DUCT FANS

GQ6SD Series. Single Packaged Heat Pump 13 SEER, R-410A 2-5 Ton Units TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS WARRANTY

DVAX-ARS. Roof-mounted unit for mechanical smoke extract

Extraction arm FX100 Original

Calculation of external available Pressure. [m/s] 0,41 0,62 0,82 1,03 1,23 1,44 1,64 1,85 2,05 2,47 2,88 3,29 3,7

1/3/EN/4. Ventilation Grilles Types TRS-K TRS-R TRSE-R

For installation into ductwork

VAV Terminal Units SDS

VAV TERMINAL UNIT KYODO-ALLIED TECHNOLOGY PTE LTD

M-SERIES MHP4 MODEL NUMBER GUIDE 3 M HP F P 1 ELECTRIC HEAT PUMP PACKAGED UNITS REVISION CODE

VAV TERMINAL BOXES TYPE: BA BT

TECHNICAL DOCUMENTATION WOLF AIR HEATERS LH-EC / LH. 30m 3 /h

UTA STANDARD. Ductable units. Range. Air handling unit with high available static pressure. NEW Eco-Design Filter. V3000 control Fresh air management

Swimming Pool CSR2 Heat Recovery Equipment

Ceiling swirl diffusers with perforated face plate

Centrifugal Inline Fans Models SQ-M and BSQ-M. Direct and Belt Drive

Ventilation grilles for installation into walls, sills or rectangular

NORDexternal External louvres

Engineering Data Manual. New : available with EC motor. High Static Pressure Ductable Fan Coil Unit. Models 07 to to 4650 m 3 /h

IN-LINE DUCT FANS MIXVENT-TD Fan Systems

Air Cooled Packaged Units

DECORATIVE FAN COIL UNIT DECORATIVE FAN COIL UNIT SPECIFICATIONS

IDENTIFICATION ACCESSORIES DESCRIPTION

Type DCS FOR HORIZONTAL SWIRLING SUPPLY AIR DISCHARGE CREATING HIGH INDUCTION LEVELS, WITH FIXED AIR CONTROL BLADES

Midea Air Handling Unit

Complete HVAC Capability

Ventilation grilles for installation into walls, sills or rectangular

WGA Long throw nozzle grille

CAV controllers. Type EN. For the precise control of normal and high constant volume flows. 01/2017 DE/en PD EN 1

500-YH SINGLE DUCT AIR TERMINAL UNIT FORM EG1 (1101)

air handling units YAH

Air displacement diffusers - p 202. Diffusers with rotating nozzle - p 215. Alum jet diffusers - p 221. Steel jet diffusers - p 225

Direct Gas-Fired Make-up Air Heaters

MAJOR 2 NCH. Ductable units. High pressure and high capacity ductable units RANGE NCH Y NCH NCH I COADIS COMBI. Motor optional

Prepared By : Checked By : Approved By : Page 1 out of 6

(Thin) (Ultrathin) Suspended Air-handling Unit

Calculation of external available Pressure. 1. Criterion flow velocity (Ref. 20 C) Do not design units in conditions acc. to white areas!

Q6SE Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Single Packaged Heat Pump, Single Phase

XeteX, Inc. All Rights Reserved.

Homepage > Products > External louvres - louvre blades > Mechanically self-powered dampers > Non-return dampers > Type KUL.

Ventilation grilles for installation into walls, sills or rectangular

IN-LINE MIXED FLOW DUCT FANS MIXVENT-TD Fan Systems

CADENZA. Sound attenuator with tapered acoustic baffles for rectangular ducts QUICK FACTS

Air-Cooled Liquid Chiller with integrated hydraulic module

CAV controllers. Type EN-Ex. For the precise control of normal and high constant volume flows in potentially explosive atmospheres (ATEX)

Ductable Modular Fan Coil Unit VPX. Technical Brochure TM VPX-W.2GB Date : May 2004 Supersedes : TM VPX-W.1GB/08.03

VAV/CAV BOXES COMMERCIAL BUILDINGS INNOVATIVE VENTILATION & HEATING

AHF - Exhaust Grille. Halton AHF. Exhaust Grille

BSB. SINGLE INLET CENTRIFUGAL FAN with Backward Wheels

CHP

Cubic unit cooler. SKB semi-industrial range

CONTROL DAMPERS. Model Model 1370CB. Model 1380CB. Model 1390CB B7

MOTORIZED VOLUME DAMPER

MegaBox Product-specific information

Guide Specifications. General. Casing. Coil/Drain pan. Fan/Motor

Optima EXHAUST GRILL AND AIR LOUVER. Perforated Ceiling Diffusers. Features: Standard square sizes:

Kitchen exhaust fan GLEB

HDF - Exhaust Grille. Halton HDF. Exhaust Grille

Chassis Access Fans Motors Speed Control Coils The Condensate Tray Insulation Spigots Controls Enclosure Control Valves Filters Rev A

Multi-Port Centrifugal Fans for Round Duct

CENTRIFUGAL FAN COIL UNIT VCE

Adriatic for individually suspended installation Exposed active climate beam with cooling, heating and ventilation

BDB DIDW CENTRIFUGAL FAN with Backward Wheel TYPE X TYPE T

INTRODUCTION CP 06 F C - A 4 L - F GENERAL DESCRIPTION DESIGN PARAMETER DUCTED CONCEALED WITH PLENUM. F - c/w Filter

TD-MIXVENT Series IN-LINE MIXED FLOW DUCT FANS TD-MIXVENT. In-Line duct fans

Concealed Ducted Split Series R22

Roof Upblast and Sidewall Exhaust

ACOUSTIC CABINET FANS FOR SUPPLY AIR APPLICATIONS CAIB/T PRO-REG Series

indoor air quality and energy saving TECHNICAL DATA HRE-TOP EC VENTILATION UNIT WITH HEAT RECOVERY FOR COMMERCIAL AND INDUSTRIAL BUILDINGS

Axial fans. What s more, non-stock models are normally available within two weeks.

PACKAGE UNIT PCA340U TECHNICAL SELECTION DATA. -10 o C UNIT FEATURES SPECIFICATION SUMMARY UNIT OPTIONS CONTROL OPTIONS UNIT COMPLIANCE.

AHN 064 to 304 EHN/CHN 064 to 304

BRIZA 22 HYBRID HEATING & COOLING

Suitable For: Bathroom Living Area Whole House Ventilation Duct Boosting Hydroponic Growing General Ventilation

GigaBox centrifugal fans Product specific information

AHTW Compact. Heat Recovery Air Handling Unit. BIM & REVIT Engineering Solutions. Acoustic Testing Laboratory College of Science & Technology

CAV controllers. Type RN. For the precise control of constant volume flow rates PD RN 1

TECHNICAL SPECIFICATIONS

External grilles USAV, USVN, USSV and SVN TECHNICAL DATA

Midea 50Hz AC Fan Coil Unit 2-Pipe Floor-standing Series Technical Service Manual

BACKWARD CURVE CENTRIFUGAL FANS KABB / KABT Series

VAV terminal units. Type TVM. For dual duct systems PD TVM 1

ERV ENERGY RECOVERY VENTILATOR 60 HZ. Indoor / Outdoor 500 to 10,000 cfm Capacity ERV I - D - D - P - 1 MODEL NUMBER IDENTIFICATION

Product Data. Features/Benefits 50JS SINGLE-PACKAGED HEAT PUMP 50 HZ UNITS 7 TO 18 KW (2 TO 5 NOMINAL TONS)

BAC / BHC Product Specifications

1 AIR HANDLING UNIT TYPE AIR ACCESS 75

ICE-Trade Winding Machines

Transcription:

Armatures and Heaters - more than functional

I n d e K l i m a M i l j ø A / S IndeKlimaMiljø A/S, or just, takes advantage in many years of experience as well internally as with our partners and suppliers of solutions for the ventilation business. Hence has the dynamics of the small organization and the competences of the larger companies., was founded in 3, and acquired by the present owners at the beginning of 8. The starting point is everybody s demand for a comfortable indoor climate and our need for a healthy environment. From this point new products and methods are developed in close collaboration with architects, engineers and installers to form overall solutions based on the expertise and products from. aims for total solutions, and we therefore appreciate a close dialog with the costumer and engineering company regarding the best possible solution to the actual job.

Content Subject Page Fresh air units and accessories Comfort 3 Comfort 1 7 Entra 7e 1 Entra 1i 13 Entra i 16 Accessories for fresh air units CID 19 CID 31 Grilles 1

Comfort 3 Description Comfort 3 is a fresh air unit complete with heater, thermostat and filter. Comfort 3 is ideal for tempering of replacement air in rooms with extraction of used air. Filter Comfort 3 s filter is conveniently located immediately behind the front. The filter ensures easy and uncomplicated cleaning or replacement. The standard filterer is made of easy cleanable polyester foam. Allergic filter of filter grade EU7 is available as option. Air intake Comfort 3 is delivered with an outside grille as standard, which is developed for extremely low air resistance. The grille protects efficiently against rain etc. Wall duct with dampers The wall ducting is round with an internal diameter of Ø. The duct is equipped with an aerodynamic and self-regulating damper. At a pressure drop of around. pa. the damper startsclosing to prevent over ventilation. Silencing Under normal conditions the Comfort 3 offers sufficient damping. Supplemental damping can be achieved with an integrated silencer built into the wall duct. Heating coil Comfort 3 is built around a heating element. A special system protects it against damages due to freezing the element. The heating element is built in a way to ensure a uniform distribution of heat across the element. This means fresh air without draft. Counter damper Comfort 3 is equipped with an efficient counter damper which prevents room air to pass backwards out through the unit due to negative pressure on the rear side of the building. Along with the wind damper this counter damper is very efficient. The counter damper is purely mechanical operated with a closing pressure of only, Pa. Temperature control Behind the front an easy accessible thermostat valve is placed. The temperature of the intake air is controlled automatically with a sensing element in the air stream. The optimum function is achieved when the fresh air is app. C below desired room temperature. Factory setting is 18 C. In situations with small loads, low volumes etc., the supply temperature may vary. Maintenance Comfort 3 can be opened with special tooling, where after access to filter, thermostat, heating element and damper is granted. Technical data Air capacity: Distribution length: Heating capacity: Water connection: Water connection: max. 3 l/s (16 m3/h), m/s at 1, m 1,, kw x 3/8" internal. max.,3 bar diff. pressure Subject to changes of

Performance data Air capacity Mounting on inner wall The centre of the Ø1-wall duct hole at the inner side of the wall, must be located at least 33 mm above the floor. The armature front (B x H = 31 x 36) is bigger than the wall duct and covers the valves and thermostat. Hidden pipe connection When using hidden connection, the distances between holes and the pipe connections are very important. (C-C 13 mm). Visible pipe connection When using visible connections the pipes are placed 6 mm and 1 mm to the left of the centre line. Connections are ⅜ thread. The curves apply to Comfort 3 with PPI standard filter and EU 7 filter. Wall duct Silencerer Winddamper Grille Heating element with counter damper Armature front Frame mounted/removed by means of finger screws The front can be removed when locking spring is released through hole at the bottom using thin pin or needle Distance between wind damper and silencer to ensure free movement of damper blades When finger screw is loosened the heating element can be tilted for easy cleaning or mounting of silencer Subject to changes of

Dimensioning Diagram 1A Temperatures 7/ C t v=3 C Diagram Temperature increase P v q l t l Diagram 1B Temperatures / C t v=1 C Diagram 3 Waterflow P v t v q v Diagram 1C Temperatures 9/7 C t v= C Diagram Pressuredrop q v P v Designations P v= Heating power (KW) T u= Outside temperature ( C ) t v= Water temperature ( C ) t l= Air temperature ( C ) t v= Temperature diff. water ( C ) t l= Temperature diff. air ( C ) q v= Waterflow (l/s) q l= Air flow (l/s) P v= Pressuredrop water (kpa) P l= Pressuredrop air (kpa) Example Ventilation demand 3 l/s Outside temperature -1 C Supply/return temperatures 7/ C From this you get heating power, air temperature and pressure drop. Solution: Diagram 1A : Heating power is 1, kw at 3 l/s Diagram : With 1, kw and 3 l/s you get delta t 1 38 C Supply air temperature = -1 + 38 = 6 C Diagram 3 : With 1, kw and temperature diff. of 38 C (7/ C ) the water flow is =,1 l/s Diagram : Pressuredrop is 1 kpa at a flow of,1 l/s Subject to changes 6 of

Comfort 1 Description Comfort 1 is a fresh air unit complete with heater, thermostat and filter. Comfort 1 is ideal for tempering of replacement air in rooms with extraction of used air. Filter Comfort 1 s filter is located behind the heating coil. The filter ensures easy and uncomplicated cleaning or replacement. The standard filterer is made of easy cleanable polyester foam. Allergic filter of filter grade EU7 is available as option. Air intake Comfort 1 is delivered with an outside grille as standard, which is developed for extremely low air resistance. The grille protects efficiently against rain etc. Wall duct with dampers The wall ducting is round with an internal diameter of Ø31. The duct is equipped with an aerodynamic and selfregulating damper. At a pressure difference of around. pa. the damper starts closing to prevent over ventilation. Silencing Under normal conditions the Comfort 1 offers sufficient damping. Supplemental damping can be achieved with an integrated silencer built into the wall duct.. Heating coil Comfort 1 is built around a heating element. A special system protects it against damages due to freezing the element. The heating element is built in a way to ensure a uniform distribution of heat across the element. This means fresh air without draft. Counter damper Comfort 1 is equipped with an efficient counter damper which prevents room air to pass backwards out through the unit due to negative pressure on the rear side of the building. Along with the wind damper this counter damper is very efficient. The counter damper is purely mechanical operated with a closing pressure of only, Pa. Temperature control Behind the front an easy accessible thermostat valve is placed. The temperature of the intake air is controlled automatically with a sensing element in the air stream. The optimum function is achieved when the fresh air is app. C below desired room temperature. Factory setting is 18 C. In situations with small loads, low volumes etc., the supply temperature may vary. Maintenance Comfort 1 can be opened with special tooling, where after access to filter, thermostat, heating element and damper is granted. Technical data Air capacity: Distribution length: Heating capacity: Water connection: Water connection: max. 1 l/s (36 m3/h), m/s at 1, m,, kw x 3/8" internal. max.,3 bar diff. pressure Subject to changes 7 of

Performance data Air capacity (Pa) 6,,, 3,, 1, Std. [Pa] EU7 [Pa] Mounting on inner wall The centre of the Ø3-wall duct hole at the inner side of the wall, must be located at least. 98 mm above the floor. The armature front (B x H = 7 x ) is bigger than the wall duct and covers the valves and thermostat. Hidden pipe connection When using hidden connection, the distances between holes and the pipe connections are very important. (C-C 13 mm). Visible pipe connection When using visible connections the pipes are placed 6 mm and 1 mm to the left of the centre line. Connections are ⅜ thread., 7 1 1 The curves apply to Comfort 1 with (l/s) PPI standard filter and EU 7 filter. Wall duct Silencer Winddamper Grille Heating element with counter damper Armature front Frame mounted/removed by means of screw Distance between wind damper and silencer to ensure free movement of damper blades When finger screw is loosened the heating element can be tilted for easy cleaning or mounting of silencer The front can be removed when locking spring is released through hole at the bottom Subject to changes 8 of

Dimensioning Diagram 1A Temperatures 7/ C t v=3 C Diagram Temperature increase P v q l t l t l ( C) 6 7 1 Diagram 1B Temperatures / C t v=1 C 3 1 6 8 1 7 6 3 1 6 8 1 q l (l/s) Diagram 1C Temperatures 9/7 C t v= C Designations P v= Heating power (KW) T u= Outside temperature ( C ) t v= Water temperature ( C ) t l= Air temperature ( C ) t v= Temperature diff. water ( C ) t l= Temperature diff. air ( C ) q v= Waterflow (l/s) q l= Air flow (l/s) P v= Pressuredrop water (kpa) P l= Pressuredrop air (kpa) q l (l/s) -1-1 -1-1 -1-1 PV (kw) 1 3 6 Diagram 3 Waterflow P v t v q v 3 1 3 1 qv (l/s),,,1,1, ΔPv(kpa) 1 1 1 Diagram Pressuredrop q v P v tv ( C) qv (l/s),,,6,8,1 Example Ventilation demand 1 l/s Outside temperature -1 C Supply/return temperatures 7/ C From this you get heating power, air temperature and pressure drop. Solution: Diagram 1A : Heating power is,1 kw at 1 l/s Diagram : With,1 kw and 1 l/s you get delta t 1 3 C Supply air temperature = -1 + 3 = C Diagram 3 : With,1 kw and temperature diff. of 3 C (7/ C ) the water flow is =,3 l/s Diagram : Pressuredrop is, kpa at a flow of,3 l/s Subject to changes 9 of

Entra 7e Description Entra 7e is a freshair unit complete with heating coil, electronic control and filter. Silencing Under normal conditions the Entra 7e offers sufficient damping. Supplemental damping can be achieved with an integrated silencer built into the wall duct. Heating coil Entra 7e is built around a heating element. A special system protects it against damages due to freezing the element. The heating element is built in a way to ensure a uniform distribution of heat across the element. This means fresh air without draft. Entra 7e is ideal for tempering of replacement air in rooms with extraction of used air. Filter Entra 7e s filter is conveniently located immediately behind the front. The filter ensures easy and uncomplicated cleaning or replacement. The standard filterer is made of easy cleanable polyester foam. Air intake Entra 7e is delivered with an outside grille as standard, which is developed for extremely low air resistance. The grille protects efficiently against rain etc. Wall duct with dampers The wall ducting is round with an internal diameter of Inner diameter Ø. The duct is equipped With et motor driven damper acting as a regulating damper and closing damper. The controller adjusts the opening in case of low temperature or user input. Counter damper Entra 7e is equipped with an efficient counter damper which prevents room air to pass backwards out through the unit due to negative pressure on the rear side of the building. Along with the wind damper this counter damper is very efficient. The counter damper is purely mechanical operated with a closing pressure of only, Pa. Temperature control Behind the front the control and motor valve is located. The supply temperature is regulated automatically by the motor controlled valve and a sensor in the supply air. The optimum function is achieved when the fresh air is app. C below desired room temperature. In situations with small loads, low volumes etc., the supply temperature may vary. Maintenance Entra 7e can be opened with special tooling, where after access to filter, thermostat, heating element and damper is granted. Technical data Air capacity: max. 7 m3/h Distribution length:, m/s at 1, m Heating capacity: 6, 1, kw Water connection: x 3/8". Water connection: max.,3 bar diff. pressure Subject to changes 1 of

Performance data Air capacity (Pa),,, 3, 3,, Std. [Pa] EU7 [Pa] Hidden pipe connection When using hidden connection, the distances between holes and the pipe connections are very important. (C-C 13 mm). Visible pipe connection When using visible connections the pipes are placed 6 mm and 1 mm to the left of the centre line. Connections are ⅜ thread., 1, 1,,, 7 1 The curves apply to Entra 7e with (m 3 /h) PPI standard filter and EU7 filter. Damper connecting Grille Damper Damper motor Wall duct Control box Filterframe Front Motorvalve Mounting on inner wall The centre of the Ø1-wall duct hole at the inner side of the wall must be located at least. mm above the floor. The armature front (B x H = 6 x 73) is bigger than the wall duct and covers the valves and thermostat. The front can be removed by loosening the screw at the buttom Subject to changes 11 of

Dimensioning Diagram 1A Temperatures 7/ C t v=3 C Diagram Temperature increase P v q l t l 1 1 8 6 6 8 1 1 16 1 8 6 6 8 8 6 8 q l (l/s) Diagram 1B Temperatures / C t v=1 C q l (l/s) Diagram 1C Temperatures 9/7 C t v= C Designations P v= Heating power (KW) T u= Outside temperature ( C ) t v= Water temperature ( C ) t l= Air temperature ( C ) t v= Temperature diff. water ( C ) t l= Temperature diff. air ( C ) q v= Waterflow (l/s) q l= Air flow (m3/h) P v= Pressuredrop water (kpa) P l= Pressuredrop air (kpa) q l (l/s) -1-1 -1-1 -1-1 -1-1 -1 t l ( C) 6 1 1 8 6 1 3 6 3 1 ΔPv(kpa) 3 3 1 1 qv (l/s),,1,1, 1 9 PV (kw) 6 8 1 1 1 16 Diagram 3 Waterflow P v t v q v tv ( C),,1,,3, Diagram Pressuredrop q v P v Example qv (l/s) Ventilation demand 7 m3/h Outside temperature -1 C Supply/return temperatures 7/ C From this you get heating power, air temperature and pressure drop. Solution: Diagram 1A : Heating power is 8,3 kw at l/s Diagram : With 8,3 kw and 7m3/h you get delta t 1 33 C Supply air temperature = -1 + 33 = 1 C Diagram 3 : With 8,3 kw and temperature diff. of 3 C (7/ C ) the water flow is =,7 l/s Diagram : Pressuredrop is 1 kpa at a flow of,7 l/s Subject to changes 1 of

Entra 1i Description Entra 1i is a fresh air unit complete with heater, thermostat and filter, for build in. Silencing Under normal conditions the Entra 1i offers sufficient damping. Supplemental damping can be achieved with an integrated silencer built into the wall duct. Heating coil Entra 1i is built around a heating element. A special system protects it against damages due to freezing the element. The heating element is built in a way to ensure a uniform distribution of heat across the element. This means fresh air without draft. Entra 1i is ideal for tempering of replacement air in rooms with extraction of used air. Filter Entra 1i s filter is conveniently located immediately behind the front. The filter ensures easy and uncomplicated cleaning or replacement. The standard filterer is made of easy cleanable polyester foam. Air intake Entra 1i is delivered with an outside grille as standard, which is developed for extremely low air resistance. The grille protects efficiently against rain etc. Wall duct with dampers Wall duct in round shape. Inner diameter Ø. The duct is equipped With a winddamper which acts as a regulating damper. If the airflow across the damper is too high, the opening is reduced to ensure correct supply temperature. At a pressure drop of around. pa. the damper starts closing to prevent over ventilation. Counter damper Entra 1i is equipped with an efficient counter damper which prevents room air to pass backwards out through the unit due to negative pressure on the rear side of the building. Along with the wind damper this counter damper is very efficient. The counter damper is purely mechanical operated with a closing pressure of only, Pa. Temperature control Behind the front the thermostat and valve is placed easily accessible. The temperature of the supply air is regulated automatically by a sensor in the airstream. The optimum function is achieved when the fresh air is app. C below desired room temperature. In situations with small loads, low volumes etc., the supply temperature may vary. Maintenance Entra 1i kan can be opened with special tooling, where after access to filter, thermostat, heating element and damper is granted. Technical data Air capacity: max. 1 m3/h Distribution length:, m/s at 1, m Heating capacity:,9,3 kw Water connection: x 3/8". Water connection: max.,3 bar diff. pressure Subject to changes 13 of

Performance data Air capacity (Pa) 6,, Std. [Pa] EU7 [Pa] Pipe connection When connecting, the distances between holes and the pipe connections are very important. (C-C 13 mm). The pipes are to be placed mm to the right and 113 mm to the left of the centre line. Distances from the wall to the pipes are 9, mm. Connections are ⅜ thread., 3,, 1, Wall duct Grille Wind damper Front Thermostat, 1 3 (m3/h) The curves apply to Entra 1i with PPI standard filter and EU7 filter. The front can be removed by loosening the screw at the buttom Mounting on inner wall The centre of the Ø-wall duct hole at the inner side of the wall, must be located at least. 3 mm above the floor. The armature front (B x H = 3 x 397) is bigger than the wall duct and covers the valves and thermostat. Subject to changes 1 of

Dimensioning Diagram 1A Temperatures 7/ C t v=3 C Diagram Temperature increase P v q l t l -1-1 -1 t l ( C) 6 7 1 1 1 1 ql (m3/h) 3 6 9 1 1 P V (kw) 1 3 Diagram 1B Temperatures / C t v=1 C Diagram 3 Waterflow P v t v q v, 1, -1-1 -1 P v (kw) 3 1 t v ( C) 1 1, q l (m3/h) 3 6 9 1 1 1 q v (l/s),,,,6 Diagram 1C Temperatures 9/7 C t v= C 3, 1, 1, q l (m3/h) 3 6 9 1 1 Designations P v= Heating power (KW) T u= Outside temperature ( C ) t v= Water temperature ( C ) t l= Air temperature ( C ) t v= Temperature diff. water ( C ) t l= Temperature diff. air ( C ) q v= Waterflow (l/s) q l= Air flow (m3/h) P v= Pressuredrop water (kpa) P l= Pressuredrop air (kpa) -1-1 -1 Diagram Pressuredrop q v P v ΔPv(kpa) 1 1 1 8 6 Example qv (l/s),1,3,,6 Ventilation demand 1 m3/h Outside temperature -1 C Supply/return temperatures 7/ C From this you get heating power, air temperature and pressure drop. Solution: Diagram 1A : Heating power is 1,7 kw at 1 m3/h Diagram : With 1,7 kw and 1 m3/h you get delta t 1 38 C Supply air temperature = -1 + 38 = 6 C Diagram 3 : With 1,7 kw and temperature diff. of 3 C (7/ C ) the water flow is =,1 l/s Diagram : Pressuredrop is 1 kpa at a flow of,1 l/s Subject to changes 1 of

Entra i Description Entra i is a fresh air unit complete with heater, thermostat and filter, for build in. Silencing Under normal conditions the Entra i offers sufficient damping. Supplemental damping can be achieved with an integrated silencer built into the wall duct. Heating coil Entra i is built around a heating element. A special system protects it against damages due to freezing the element. The heating element is built in a way to ensure a uniform distribution of heat across the element. This means fresh air without draft. Entra i is ideal for tempering of replacement air in rooms with extraction of used air. Filter Entra i s filter is conveniently located immediately behind the front. The filter ensures easy and uncomplicated cleaning or replacement. The standard filterer is made of easy cleanable polyester foam. Air intake Entra i is delivered with an outside grille as standard, which is developed for extremely low air resistance. The grille protects efficiently against rain etc. Wall duct with dampers Wall duct in round shape. Inner diameter Ø31. The duct is equipped With a winddamper which acts as a regulating damper. If the airflow across the damper is too high, the opening is reduced to ensure correct supply temperature. At a pressure drop of around. pa. the damper starts closing to prevent over ventilation. Counter damper Entra i is equipped with an efficient counter damper which prevents room air to pass backwards out through the unit due to negative pressure on the rear side of the building. Along with the wind damper this counter damper is very efficient. The counter damper is purely mechanical operated with a closing pressure of only, Pa. Temperature control Behind the front the thermostat and valve is placed easily accessible. The temperature of the supply air is regulated automatically by a sensor in the airstream. The optimum function is achieved when the fresh air is app. C below desired room temperature. In situations with small loads, low volumes etc., the supply temperature may vary. Maintenance Entra i can be opened with special tooling, where after access to filter, thermostat, heating element and damper is granted. Technical data Air capacity: max. m3/h Distribution length:, m/s at 1, m Heating capacity:,6,3 kw Water connection: x 3/8". Water connection: max.,3 bar diff. pressure Subject to changes 16 of

Performance data Air capacity (Pa) 6,, Std. [Pa] EU7 [Pa] Pipe connection When connecting, the distances between holes and the pipe connections are very important. (C-C 13 mm). The pipes are to be placed 3mm and 188 mm to the left of the centre line. Distance from the wall to the pipes is 9, mm. Connections are ⅜ thread., 3,, 1, Wall duct Grille Wind damper Front, The curves apply to Entra i with PPI standard filter and EU7 filter. Mounting on inner wall 1 3 (m3/h) The centre of the Ø3-wall duct hole at the inner side of the wall, must be located at least. mm above the floor. The armature front (B x H = x 6) is bigger than the wall duct and covers the valves and thermostat. Thermostat The front can be removed by loosening the screw at the buttom Subject to changes 17 of

Dimensioning Diagram 1A Temperatures 7/ C t v=3 C Diagram Temperature increase P v q l t l -1-1 -1 t l ( C) 6 1 3 3 1 ql (m3/h) 1 3 Diagram 1B Temperatures / C t v=1 C 1 3 6 Diagram 3 Waterflow P v t v q v PV (kw) -1-1 -1 3 1 1 tv ( C) 3 3 1 q l (m3/h) 1 3 Diagram 1C Temperatures 9/7 C t v= C 7 6 3 1 q l (m3/h) 1 3 Designations P v= Heating power (KW) T u= Outside temperature ( C ) t v= Water temperature ( C ) t l= Air temperature ( C ) t v= Temperature diff. water ( C ) t l= Temperature diff. air ( C ) q v= Waterflow (l/s) q l= Air flow (m3/h) P v= Pressuredrop water (kpa) P l= Pressuredrop air (kpa) -1-1 -1 1,,,1,1, Diagram Pressuredrop q v P v ΔPv(kpa) 1 1 Example qv (l/s) qv (l/s),,,6,8,1 Ventilation demand m3/h Outside temperature -1 C Supply/return temperatures 7/ C From this you get heating power, air temperature and pressure drop. Solution: Diagram 1A : Heating power is,3 kw at m3/h Diagram : With,3 kw and m3/h you get delta t 1 33 C Supply air temperature = -1 + 3 = 1 C Diagram 3 : With,3 kw and temperature diff. of 3 C (7/ C ) the water flow is =,3 l/s Diagram : Pressuredrop is kpa at a flow of,3 l/s Subject to changes 18 of

Trykfald (pa) Dæmpning (db) CID Description Silencer for mounting in wall duct for ø mm duct. Damping The sound damping depends on number of units mounted. The models may be combined as needed. 3 Dæmpning 1 The silencer can combined with additional units to achieve maximum damping depending on space available. Space requirements Depending on wall thickness different number of units can be placed. Space requirements = (Wall thickness in mm - 1). Round the measure down till nearest whole number of units. Air resistance Pressure drop across the total damper depends on number of units mounted. 6 Measures Trykfald mm 1 1 3 3 Flow (l/s) 1 mm 1 mm mm 1 - Total damping incl. heating element The total damping is shown in the table below, and depends on number of units mounted. Included is a standard heating element. Konfiguration Vægtet dæmpningstal (db) 1 mm 3 1 mm 3 mm 3 mm 3 Construction 1 3 Frekvens (Hz) Dimension (Diameter): Thickness small model: Thickness large model: ø mm 1 mm 1 mm Front and rear side: Neopren rubber Damper material: Basotech Weight small model:, kg. Weight large model:, kg. 1 mm 1 mm mm mm Subject to changes 19 of

Trykfald (pa) Dæmpning (db) CID 31 Description Silencer for mounting in wall duct for ø31mm duct. Damping The sound damping depends on number of units mounted. The models may be combined as needed. Dæmpning,, 1, The silencer can combined with additional units to achieve maximum damping depending on space available. Space requirements Depending on wall thickness different number of units can be placed. Space requirements = (Wall thickness in mm - 1). Round the measure down till nearest whole number of units. Air resistance Pressure drop across the total damper depends on number of units mounted. 1 8 Measures Trykfald 1mm 1mm mm mm 1 3 6 7 8 9 1 11 Flow (l/s) 1,,, -, Total damping incl. heating element The total damping is shown in the table below, and depends on number of units mounted. Included is a standard heating element. Konfiguration Vægtet dæmpningstal (db) 1mm 3 1mm 31 mm 33 mm 3 Construction 1 3 Frekvens (Hz) Dimension (Diameter): Thickness small model: Thickness large model: ø31 mm 1 mm 1 mm Front and rear side: Neopren rubber Damper material: Basotech Weight small model:,3 kg. Weight large model:, kg. 1mm 1mm mm mm Subject to changes of

Grilles BRYG Rectangular grille. The grille is made of a mounting frame with flanges, water nose and a removable frame with net on the inside. Made from galvanized steel plate as standard. Also available in stainless steel, aluzink, copper or powder coated in any color. BRYV Squared air intake grille. This grill is made with vertical aluminum intake openings with water drains. Water entering with the air is trapped and flows into a drain at the bottom and lead out to the outside. The grille can be delivered with electrical defrosting. The grille is made from aluminum profiles. Also offered with anodized surface or powder painted. BRYI Heavy duty Squared air intake grille. The grille is made from extra heavy materials, specially suited for schoolyards etc. where extra strength is needed. It has deep profiles with dismountable grille parts for easy cleaning and a removable frame with net on the inside. The grille can be delivered with electrical defrosting. Made from galvanized steel plate as standard. Also available in stainless steel or powder coated in any color. BRYJ Squared/circular air intake grille. Standard grille of die cast aluminum. The grille is offered with steel net on the inside. Also available in powder coated in any color. Subject to changes 1 of

_ www.ikm.dk tlf + 7 39 salg@ikm.dk