... PureLine PQ. Technical Specification. PureLine PQ (Disinfection) Models PQ PQ UV Chamber. Cabinet

Similar documents
EXPERTS IN ULTRAVIOLET DISINFECTION

Treatment Chamber. Control System

UV sterilizers and spare parts

Engineered to Higher Standards

JUMO DELOS SI. Precision pressure transmitter with switching contacts and display. Application. Brief description. Key features.

Treatment Chamber. Control System. ETS Manual Updated 10/24/05

Treatment Chamber. Control System. ECP Units designed to be the best.

T EN Type 3349 Aseptic Angle Valve With USP-VI diaphragm

SITRANS P measuring instruments for pressure

Series 240 Type and Type Pneumatic Control Valves Type 3347 Hygienic Angle Valve

SITRANS F flowmeters SITRANS F US. SITRANS FUT1010 Ultrasonic flowmeter. Overview. Application

The Polaris MA1 is the first liquid flow meter offered by Magnetrol, expanding the already diverse level and flow measurement portfolio that has been

Pressure Transmitters for Sanitary Applications Model SA-11

Flow Measurement SITRANS F M. Flow sensor MAG /85. Overview

Technical Data Sheets

abc CPD7948/075 Rotors, rotor shafts and rotor casings are coated with an anti-corrosive and anti wear coating to prolong element life and efficiency.

Rental Power QSB7 series engine

Flow Measurement SITRANS F C

T EN Type 3347/3379 Pneumatic Control Valve Type 3347 Hygienic Angle Valve

Digital ph transmitter

Thermowell For sanitary applications Model TW61, for orbital welding

Level instruments. Continuous level measurement - Capacitance transmitters SITRANS LC300. 5/262 Siemens FI Overview.

Digital ph transmitter

Magnetic-Inductive Flow Meter FMI

OPTISWITCH 4000/5000. Vibration level switches for liquids

Magnetic-inductive flow meter EPS / UMF2. Technical data sheet

UFM 800 W, C and UFM 800 W Hot Tapping. Ultrasonic flowmeters. for water and wastewater

Insertion magnetic inductive flowmeter

Technical specification

Level Measurement Point level measurement - RF Capacitance switches

Output signal active note. Measuring range rel. pressure. Electrical Data Power supply DC V, ±10%, 1.1 W

SATRON VTe pressure transmitter

Isoil Industria a worldwide supplier of electromagnetic flowmeters Total flow control. Accurate to the drop.

SATRON VDt Differential Pressure Transmitter

Turbidity and Suspended Solids Transmitter

Pressure transmitter COMPACT ECOnomic

Flow Measurement SITRANS F C. Flow sensor MASS 2100 DI 3 to DI 40. 4/180 Siemens FI

Rosemount 8750WA Magnetic Flowmeter System For Water and Wastewater Industries

ATS22D88Q soft starter-ats22-control 220V-power 230V (22kW)/ V(45kW)

Rental Power QSL9 series engine

Pressure transmitters for industrial applications Type MBS 4510

OPTIFLUX 6000 Technical Datasheet

Each pump shall be equipped with carbon/graphite vanes. A vacuum relief valve shall be incorporated into the design of the pump.

BUTTERFLY VALVES + SA ACTUATOR

Each pump shall be equipped with carbon/graphite vanes. A vacuum relief valve shall be incorporated into the design of the pump.

Oxiperm 164 D for 30 to 2000 g/h

Miniature resistance thermometer For sanitary applications Model TR21-A, with flange connection


Model 261GC/GG/GJ/GM/GN Gauge Model 261AC/AG/AJ/AM/AN Absolute. Series 2600T Pressure Transmitters. Engineered solutions for all applications

The pumps shall be Oil Free and Variable speed controlled by Pressure Transducer, PLC and inverter.

Oscillating piston flowmeters Series COVOL Positive displacement flowmeter for liquids

Technical Data Sheets

Thermowell For sanitary applications Model TW61, for orbital welding

Oxiperm 164 C for 150 to 2500 g/h

PUREFLO 21 4-CHAMBER DIAPHRAGM PUMPS

Micro Motion F-Series Coriolis Flow and Density Meters

2SGT. Electronic Pressure Instrument. Three Separate Functions in a Single Loop-Powered Device

TECHNICAL DESCRIPTION

Magnetic-Inductive flow Meter fmi

UVMAX Light Commercial Series Model description weight NOTES

Solid State Electronic Pressure Switch with Integral LED Display Model PSD-10

Technical Data Sheets

Product Data Sheet 4184 N/17X. The engineer's choice

Flow Measurement SITRANS F C

Level Measurement. Point level measurement Capacitance switches. Pointek CLS200 Standard. 4/18 Siemens FI Overview.

WATERFLUX 3070 Quick Start

SANITARY PRESSURE GAUGES

SATRON VVFe Pressure Transmitter

JCB DIESEL GENERATOR TECHNICAL SPECIFICATIONS

Flow Measurement SITRANS F M

Power (kva) 3 Phase,50 Hz, PF 0.8. STANDBY RATING (ESP) PRIME RATING (PRP) Standby Amper. kw kva kw kva 400/

Flow Measurement SITRANS F M. Flow sensor MAG 5100 W. 4/68 Siemens FI Overview

Level Measurement. Point level measurement Capacitance switches. Pointek CLS200 Standard. icenta Controls Ltd

This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

Portable pressure calibrator, Wally Box III Model CPH7600

We reserve the right to alter data according to improvements made. Previous documents become invalid with the issue of this document.

+ = Angle-seat Valve System for continuous control. Type 8802/2300 electro-pneumatically operated angle-seat valve

Flow Measurement SITRANS F M. Flow sensor MAG 1100 F 4/57

Pressure transmitter for industrial applications Type MBS 4510

SITRANS F M. Flow sensor MAG 1100 F 3/59

JCB DIESEL GENERATOR TECHNICAL SPECIFICATIONS

This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

SATRON VT Pressure Transmitter

Type A-10 General Purpose Pressure Transmitters

NON-RETURN VALVE RT25

ALTI-NEXIS V OPERATING LIMITS APPLICATIONS ADVANTAGES. Flow rates up to: 320 m 3 /h Delivery head up to: Maximum operating pressure:

Flow Measurement SITRANS F M

Air operated Pinch Valve type VMC

This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

These documents contain additional information concerning related products from Rockwell Automation.

Point level measurement Capacitance switches

Hydrosafe - Model HSFS

Rosemount 3051CFA Annubar Flowmeter


JUMO tecline CR-4P Conductive 4-Electrode Conductivity Sensor

Thermowell For sanitary applications Model TW61, for orbital welding

Voltage kva kw kva kw Amp 400/ ,00 388,00 425,00 340,00 613,00 OTHER ACCESSORIES

8000 Series Liquid Flow Meter

B BASIC HEAT TREATMENT CONSOLE

Mini Pressure Transmitter HA7

Transcription:

PureLine PQ PureLine PQ (Disinfection) Models PQ0200 - PQ 1100... Technical Specification UV Chamber Material: Internal finish: Stainless steel 316L <0.8µm Ra max, welds left as laid electropolished and passivated External finish: Brushed to K280 electropolished and passivated Process (mating) connections: Flange DN series PN10 rated Drain connection: BSPT End plate: Removable bolted plates Degree of protection: IP54 (NEMA 12) Arc tube (lamp): Medium pressure / high purity quartz Arc tube enclosure: High purity quartz Number of lamps: 2 to 4 Expected lamp life: 9000 hours Temperature sensor: Yes UV monitor: 4 Pre calibrated DVGW compliant dry UV monitors Working fluid temperature: +41 F to +104 F Maximum CIP temperature: 203 F with electrical cabinet isolated Hydrostatically pressure tested: Yes Operating / Design pressure: 6 bar / 7 bar Pressure Loss: Typically < 100 mbar Seals: Viton and NBR 90 approved to NSF61 Cabinet Material: Painted carbon steel Degree of protection: IP54 ( NEMA 12) Supply voltages: Model PQ 0200 and PQ 0360 200-300V 50/60 Hz Model PQ 1100 400V 50/60 Hz or 480V 50/60 Hz Operating temperature range: Relative humidity: <90% Cooling fans: cable length: External contacts: +41 F to +104 F Yes 32 ft 4-20mA signal for UV dose and UV intensity, Volt free contacts for trip, warning, system available, system remote, UV on, system ready, dose valid, warming, cooling, system OK, wiper fault, ground fault, chamber/cabinet trip, cabinet temperature warning, chamber temperature warning, low UV, lamp failure, Modbus output. Inputs remote start / stop, remote reset, remote wipe cycle.

...... BREWING FOOD + DIARY BOTTLED WATER + SOFT DRINKS t: 910.232.0342 e: stew@kberg.info Visit our website for further information at www.kberg.info

... PureLine PQ... Complete Range Technical Specification Model Maximum Disinfection Maximum Disinfection Min. Flange Approx Weight (lb) Capacity * (usgpm) Capacity ** (usgpm) T 10 Size Chamber Power Power 32mJ/cm 2 RED 120mJ/cm 2 RED (%) DN (Empty) Supply (kw) PureLine PQ 0005 22.4 3.96 60 1.6 19.8 81.6 0.08 PureLine PQ 0008 35.6 7.48 60 2 19.8 81.6 0.14 PureLine PQ 00016 70.4 17.16 60 2 19.8 81.6 0. 27 PureLine PQ 0030 140.8 22.44 60 3.1 55.1 81.6 0. 27 PureLine PQ 0090 387.2 70.4 60 5.9 101.4 81.6 0. 55 PureLine PQ 0200 902 220 50 7.9 110.2 297.6 5.4 PureLine PQ 0360 1716 431.2 50 7.9 110.2 396.8 10.7 PureLine PQ 1100 4004 990 50 13.8 286.6 485 17.1 * The maximum disinfection capacity is based on a dose of 32mJ/cm 2 RED MS2 phage T 10 95% fouling factor 0.95 and end of lamp life (EOLL) 0.9 ** The maximum disinfection capacity is based on a dose of 120mJ/cm 2 RED MS2 phage T 10 95% fouling factor 0.95 and end of lamp life (EOLL) 0.9

PureLine PQ PureLine PQ (Disinfection) Models PQ 0005 - PQ 0090 Technical Specification UV Chamber Material: StSt 316L / 1.4404 Internal finish: External finish: Process (mating) connections: Drain connection: As made pipe and tube, welds left as laid electropolished and passivated Sateen polish (120 grit) electropolished and passivated Flange DN series PN16 rated BSPT End plate: Removable tri-clamp except PQ 0090 which is a bolted plate Degree of protection: IP65 equivalent to NEMA 4 but not suitable for outside use Arc tube (lamp): Arc tube enclosure: Number of lamps: 1 Expected lamp life: Temperature sensor: UV monitor: Working fluid temperature: Maximum CIP temperature: Hydrostatically pressure tested: Operating / Design pressure: Pressure Loss: Seals: Low pressure amalgam / high purity quartz High purity quartz 12000-16000 hours Yes Pre calibrated DVGW compliant dry UV monitor +41 F to +104 F 203 F with control cabinet electrically isolated Yes to PED requirements EN13445 6 bar / 7 bar Typically < 20 mbar including wiper EPDM FDA approved WQA certified to NSF61 except PQ 0005 Cabinet Material: Polyester coated carbon steel Degree of protection: IP66 / NEMA 4 Supply voltages: Operating temperature range: Relative humidity: <90% Cooling fans: cable length: External contacts: 230V (207V to 263V) 50/60Hz +41 F to +104 F No 32 ft 4-20mA signal for UV dose and UV intensity, 24V dc 10mA max for trip, warning, system available, system remote, lamp running, replace lamp and Modbus for complete remote control

...... Features Operational Features: Screen Display Features: Alarm Message Features: Safety Features: Lamp on/off Remote / local operation Validated dose calculation from fixed or variable flow with or without UVT input Option of running with dose algorithm which automatically compensates for changes in UV transmittance Selectable auto restart following power failure Event log (2000), 3 level operating menu Pre calibrated DVGW compliant dry UV monitor Dry monitor port with light trap 4 line x 20 character backlit LCD with indication of System Status Remote / local mode UV dose or intensity Alarms and warning list Date and time English language Lamp fail Low UV dose or intensity Operating outside valdated conditions System warning and trip messages Door interlocked cabinet isolator Separate door locks Ballast thermal cut out Resettable circuit breaker UV monitor port shutters (light trap) Options Approvals Validation support pack Stainless steel cabinet (304) 98 ft lead lengths Printed operating menu and safety guides in Chinese, French and German Auto-wiper pneumatic operation ANSI 150 flanges and NPT drain Tri-clamp connections to BS 4825 with tri-clamp drain internal finish <0.38µm Ra maximum welds as laid electropolished and passivated CIP maximum 266 F with cabinet electrically isolated In field reference monitor and intensity meter (LP) UL 61010-1 and IEC 61010-1 CE following the low voltage directive and EMC directives conforming to EN61000-3-2,3-3, 4-2, 4-3, 4-4, 4-5, 4-6, 4-8 and 4-11 and 61326-1 class A Carollo certified to USEPA / UVDGM (2006) UV monitor is DVGW W294-3 approved All wetted materials WQA certified to NSF 61 except PQ 0005 Additional Information All dimensions are approximate for clearance purposes only. Hanovia has a policy of continuous product development, exact drawings are available on request. All specifications are subject to change without notification. Your Distributor or Hanovia Account Manager can advise on correct dosage and specific requirements. Certificate No: FM29365

PureLine PQ PureLine PQ 0005 - PQ 0090 Product Specific Data Dimensions (mm) Chamber: A D DN B C Chamber Cabinet: K L E Chamber Mounting 400-600 CRS M Cabinet Model Maximum Min. Dimensions in inches Approx Weight (lb) Disinfection T 10 unwiped dimensions Chamber Power Power Capacity* (usgpm) (%) A B C D E DN K** L** M** (Empty) Supply (kw) PureLine PQ 0005 22.4 60 54.5 50.1 5.9 51.2 4 1.6 10.2 23.6 37.4 19.8 81.6 0.08 PureLine PQ 0008 35.6 60 54.5 50.1 5.9 51.2 4 2 10.2 23.6 37.4 19.8 81.6 0.14 PureLine PQ 0016 70.4 60 54.5 50.1 5.9 51.2 4 2 10.2 23.6 37.4 19.8 81.6 0.27 PureLine PQ 0030 140.8 60 54.6 51.2 7.9 51.2 6.6 3.1 10.2 23.6 37.4 55.1 81.6 0.27 PureLine PQ 0090 387.2 60 78.1 71.9 9.8 74.8 8.1 5.9 10.2 23.6 37.4 101.4 81.6 0.55 * The maximum disinfection capacity is based on a dose of 32mJ/cm 2 RED MS2 phage T 10 95% fouling factor 0.95 and end of lamp life (EOLL) 0.9 ** Cabinet dimensions allow for door isolator, bottom cable entry and bracket space. For cooling add 11.8 inches to L and 5.9 inches to M dimensions

... Features Operational Features: Screen Display Features: Alarm Message Features: Safety Features: Lamp on/off Remote / local operation Validated dose calculation from fixed or variable flow with or without UVT input Auto-wiper electric operation Stepless lamp power 33% to 100% 4 level operating menu Pre calibrated DVGW compliant dry UV monitors one per lamp Dry monitor port 4 line x 20 character backlit LCD with indication of System Status Remote / local mode UV dose or intensity Alarms and warning list Date and time English language Lamp fail Low UV dose or intensity System warning and trip messages Door interlocked cabinet isolator Separate door locks Ballast thermal cut out Resettable circuit breaker Options Approvals Validation support pack Stainless steel cabinet (304) 98 ft lead lengths Printed operating, menu and safety guides in Chinese, French and German ANSI 150 flanges and NPT drain In field reference monitor and intensity meter (MP) UL 508A Shop Approval (except PQ 1100) CE following the machine directive 2006/42/EC, EMC directive 2004/108/EC, low voltage directive 2006/95/EC and 93/68/EEC including NEN-EN-ISO 12100-1:2003, 12100-2:2003, 13857:2008, 13850:2006, NEN-EN 349+A1:2008, EN 61000-6-3:2007 and 61000-6-2:2005 Carollo tested in accordance with USEPA UV monitor is DVGW W294-3 approved All wetted materials WQA certified to NSF 61 Additional Information All dimensions are approximate for clearance purposes only. Hanovia has a policy of continuous product development, exact drawings are available on request. All specifications are subject to change without notification. Your Distributor or Hanovia Account Manager can advise on correct dosage and specific requirements. Certificate No: FM29365

... PureLine PQ PureLine PQ 0200 - PQ 1100 Product Specific Data Dimensions (mm) Chamber: Service Access 500 A (with wiper) B Service Access 500 C Cabinet: K L Chamber D M Cabinet Model Maximum Min. Dimensions in inches Approx Weight (lb) Disinfection T 10 A B C D DN K** L** M** Chamber Power Power Capacity * (usgpm (%) (Empty) Supply (kw) PureLine PQ 0200 902 50 30.7 12.2 15.7 10.7 7.9 15.7 31.5 39.4 110.2 297.6 5.4 PureLine PQ 0360 1716 50 30.7 12.2 15.7 10.7 7.9 15.7 47.2 47.2 110.2 396.8 10.7 PureLine PQ 1100 4004 50 35.2 14.5 21.7 16 13.8 15.7 47.2 47.2 286.6 485 17.1 * The maximum disinfection capacity is based on a dose of 32mJ/cm 2 RED MS2 phage T 10 95% ** Cabinet dimensions do not allow for door isolator, cable entry and bracket space. For cooling add 600mm to L and M dimensions (300mm each side)