And ASEAN EAW WATER) Head. Office : Ruko

Similar documents
Chilled Water FCU. Horizontal Fan Coil 50hz CFM. A Series.

CFFWA Chilled/Hot Water Universal Mount Fan Coil 2-Pipe Heat / Cool Fan Coil 12,000-60,000 BTUH

HBC SERIES-PSC MOTOR HBCX SERIES-ECM MOTOR

48CWA2-00 Chilled Water Fan Coil With or Without Electric Heat 2-Pipe Heat / Cool Fan Coil 48,000 BTUH

MH1WC4W-08-1-B Chilled/Hot Water 1-Way Cassette Fan Coil

MHWW-24-H-1 Chilled/Hot Water Hi-Wall Fan Coil. Heat / Cool Fan Coil 24,000 BTUH. Rev. 1.3

Commercial Blower Coil Air Handlers

36CWA4-HW 4-Pipe Chilled & Hot Water Air Handler (120V) 4-Pipe Heat & Cool Fan Coil 36,000 BTUH

The World Leading Air-conditioning Company

24CWA4-HW 4-Pipe Chilled & Hot Water Air Handler (120V)

LOW STATIC FAN COIL UNITS District Cooling Chilled Water Application

Prepared By : Checked By : Approved By : Page 1 out of 6

MODULAR AIR HANDLING UNITS GAH SERIES

Concealed Ducted Split Series R22

HBC SERIES-PSC MOTOR HBCX SERIES-ECM MOTOR

SPECIFICATIONS AND DESIGN ARE SUBJECT TO CHANGE WITHOUT PRIOR NOTICE. EDITION 11

Precision Cooling For Business-Critical Continuity. Liebert CW. System Design Manual kW, 50 & 60Hz

PCXDMT1601. VRV AHU System STANDARD SERIES AHUR-CAVJ/DAVJ/DABVJ OUTDOOR AIR SERIES AHUR-CALJ/DALJ/DABLJ. Heat Pump 50/60 Hz R-410A

Guide Specifications. General. Casing. Coil/Drain pan. Fan/Motor

DAIKIN INDUSTRIES, LTD. Ceiling Concealed Chilled Water Fan Coil Unit (50Hz/60Hz)

Driving and Connecting Globally. Fan Coil Unit. Model : PHW-K Size : 510CMH~2720CMH. Made in Taiwan

A Division of Nailor International Inc. ECONOMY AIR HANDLERS

Product Data. FS3QX Slim Line Ducted Fan Coil With Plenum Sizes 018 thru 060 SLIM LINE DUCTED FAN COIL WITH PLENUM ON/OFF DISPLAY TEMP

Technical Sales Guide # 040 YDFC 0 1 Page 2

FCVC Series VERTICAL FAN COILS

PCXAU1601. VRV AHU System STANDARD SERIES AHUR-CAVJ/DAVJ/DABVJ OUTDOOR AIR SERIES AHUR-CALJ/DALJ/DABLJ. Heat Pump 50/60 Hz R-410A

CHILLED WATER FAN-COIL UNITS

AIR HANDLING UNITS. Customisable modular air handling unit, designed and built to suit your project requirements

Engineering Data Book

PACKAGE AIR CONDITIONERS

42CET/ 42CED Series Chilled Water Fan Coil Unit Furred-in Ceiling Model 300 to 1400 cfm Electric heater option

PCB COMMERCIAL SERIES

ROOF TOP (SERIES SR) 10.8 TO 103 KW 37,000 TO 351,000 Btuh

AIR HANDLING UNIT. MODEL: PM0809 to PM CFM to CFM

ELTAFANTECH Air Handling Unit 700 up to 42,000 CFM

D M S 760 C01 A A 1 1

Ceiling Concealed Chilled Water Fan Coil Unit

Product Data. Features/Benefits. 42BH System Fan Coil. 800 to 4000 Cfm

Midea Air Handling Unit

High Performance Fan Coils FCHG Genesis Series Horizontal

ACPSE-P Series 50Hz 410A. Rooftop Units Cooling Capacity : 26 to 1388 MBH (8 to 407 kw) Heating Capacity : 28 to 1298 MBH (8 to 380 kw)

Modular Air Handling. Up to 3,500 Litres / sec. Low profile & Plant room application. Draft. Version. Second Edition A-. AirDesign 2015 AirDesign 2016

DECORATIVE FAN COIL UNIT DECORATIVE FAN COIL UNIT SPECIFICATIONS

CHP

VERTICAL SINGLE AND DOUBLE WALL BELT DRIVE AIR HANDLER DX OR CHILLED WATER COOLING WITH HOT WATER OR ELECTRIC HEAT

SUBMITTAL. Palm Beach Gardens Fire Station. Fausto Frias

12 CB30M SERIES UNITS INCLUDING ECB29 ELECTRIC HEAT

High Static Fan Coil Units YDFC

VAHU Vertical Air Handling Unit

Engineering Data Book

Ruud Commercial Achiever Series Package Gas Electric Unit

air handling units YAH

PA95 12 SEER FEATURES 2 THRU 4 TON SINGLE PACKAGE

DOUBLE SKIN MODULAR AIR HANDLING UNIT. Round Edge (ADM-AHU)

Ruud Commercial Achiever Series Package Gas Electric Unit

BUILDING EFFICIENCY Energy Efficient Variable Speed EC Motor Fan Coil Unit Solutions Model YECFC

GENERAL ELECTRIC CONCEALED CHILLED WATER FAN COIL UNITS

High Static Pressure Duct Fan Coil Unit

Rheem Commercial Classic Series Package Gas Electric Unit

SINGLE PACKAGE AIR CONDITIONING WATER COOLED

ROOF TOP PACKAGE UNITS

FFW/FSW/FHW SERIES FLOOR EXPOSED VERTICAL FAN COIL UNITS

Package Air Conditioners

DUNHAM-BUSH ecs3 Series

PACKAGE HEAT PUMP UNITS

V33B High Efficiency 360 Cassette Indoor Models - 60HZ

CHILLED WATER DUCTED FAN COIL

BRIZA 22 HYBRID HEATING & COOLING

HEAT-RECOVERY UNITS WITH ENTHALPY/ROTARY HEAT EXCHANGER TECHNICAL MANUAL

42CLS-W Series Chilled Water Fan Coil Unit Ceiling Concealed - Duct Type Nominal: 400-2,000 CFM

Chiller, Close control and Water terminals. Air Conditioning. Light Commercial, Commercial and Industrial

technical sales guide - 60Hz Ducted Split Units HIGH AMBIENT OPERATION 52 UPTO

Vertical Floor Fan Coil Unit (Model FW)

Product Data. CFM (L/s) Dimensions. Filter Size Ship Wt. H x W x D in. (mm) FMA4P1800AL 1 1/2 18, (212) 675 (319) 36 1/2 x 20 1/2 x 15

OmegaAir Series Dedicated Outside Air Systems (DOAS) Engineering Guide

Nomenclature. Contents. Air Handling Unit SR AH 250 LP HS

Submittal DIMENSIONS SIZE FAN SIZE L W H C D E F G J K [406] [508] 25 [635] [406] 16 [406] 16 [406] 39-1/2 [1003] 44-1/2 [1130] 51 [1295] 59 [1499]

Engineering Data Book

42HS Fan Coil Unit (High Static Pressure)

Product Data. Features/Benefits 50JS SINGLE-PACKAGED HEAT PUMP 50 HZ UNITS 7 TO 18 KW (2 TO 5 NOMINAL TONS)

BAC / BHC Product Specifications

SLH 1202 to Air-to-Water Reverse Cycle Heat Pumps. With Screw Compressors. 261 to 775 kw. 287 to 853 kw

MODULAR SINGLE AND DOUBLE WALL BELT DRIVE AIR HANDLER DX OR CHILLED WATER COOLING HOT WATER OR ELECTRIC HEATING

42CHS-W Series. Chilled Water Fan Coil Unit Ceiling Concealed - Duct Type. Nominal: 400-2,000 CFM. World's No.1 Air Conditioning Expert QMS 001

Product Data. Features/Benefits. OMNIZONE 50XCR06-24 Remote Air-Cooled Indoor Self-Contained Systems with PURON Refrigerant (R-410A)

TECHNICAL GUIDE GENERAL SPECIFICATIONS COMMERCIAL SPLIT-SYSTEM COOLING UNITS FOUR PIPE SYSTEM OUTDOOR UNIT:

V33A Standard/High Efficiency 360 Cassette Indoor Models - 60HZ

Fans Air Handling Units Air Distribution Products Fire Safety Air Curtains and Heating Products Water terminals SYSCOIL. Centrifugal fan coil units

MODULAR SINGLE AND DOUBLE WALL BELT DRIVE AIR HANDLER DX OR CHILLED WATER COOLING HOT WATER OR ELECTRIC HEATING

Multi-Path RTU-TYPE 9 (RTU-1) CES-MPU-025-RE-VAV9

50 Hz AIR - COOLED SPLIT SYSTEM. Products That Perform...By People Who Care AIR CONDITIONERS WITH SCROLL COMPRESSORS

TECHNICAL GUIDE GENERAL HIGH-EFFICIENCY WATER SOURCE HEAT PUMPS AND WATER COOLED AIR CONDITIONERS

SARAVEL MINI AIR-HANDLING UNIT

Product Data. 42D Ducted Fan Coil Air Conditioners cfm

PAB SERIES 3thru6-1/3Ton. Belt Drive 10 SEER CONVERTIBLE SINGLE PACKAGE AIR CONDITIONING UNIT /01

DESCRIPTION ACCESSORIES FIELD INSTALLED SPLIT-SYSTEM EVAPORATOR BLOWERS KBBU060, KDBC090, KCBC120 & KCBC180 5 THRU 15 NOMINAL TONS SUPPLY AIR PLENUMS

WE ARE PLEASED TO PROVIDE THE ENCLOSED SUBMITTAL FOR YOUR REVIEW AND APPROVAL

CENTRIFUGAL FAN COIL UNIT VCE

ROOF TOP SINGLE AND DOUBLE WALL BELT DRIVE AIR HANDLER DX OR CHILLED WATER COOLING HOT WATER OR ELECTRIC HEATING

Efficient solutions for commercial refrigeration

Transcription:

The Winner of INDONESIA ENERGY AWARD 2013 And ASEAN ENERGY AWARD 2004 2012 AIR HANDLING UNIT (AHU CHILLED WATER) 1.600 M³/ /hr. 52.000 M³/hr EAW CHILLED WATER PT. METROPOLITAN BAYU INDUSTRI A member of Metropolitan Group in HVACR Industri Head Office : Ruko kebon Jeruk Baru Blok B No 1 2 Kebon Jeruk, Jakarta barat 11530 Website : www.ac ezone.com : JL. Raya Narogong Km. 27, Desa Klapanunggal, Kec Cileungsi Bogor, INDONESIA Ph : 82494567, 82494439, ( Hunting), FAX : 8235922 Factory

STANDARD FEATURES Casing Flat form Unit casing is built on a skeleton frame ezone, either aluminumm or galvanized steel profiles stiff joints assembled by insertion of either nylon or pieces of aluminum angle industry. This makes assembly easier and possible to put the air handling unit in a location that cannot be considered before Slope design for drain pan with a sheet of galvanized or stainless steel to prevent the development of the fungus at the drain water and to maintain air quality inside the unit, and acoustic (sound sensitive) project. Panels Double skin ezone panel has a thickness of 25 mm with a density of 45 kg / m³. panel manufactured by polyurethane foam between two sheets of metal. Exterior and interior walls are made with a thickness of 0..5 mm pre painted galvanized sheet and film plant protection applied. Panels are assembled with mechanical fasteners that can be assembled pairs one by one. Access doors can be built with the same material as the panel casing will allow a full 180 swing on hinges reinforced foam. Fan All units equipped with highh performance plug fans with scaling in accordance to AMCA Standard for maximum performance., The following fan type are available : Centrifugal fan with Forward Curved and Backward Curved Volume flow 1.700m³/h to 49.500m³/h Total pressure up to 1000 Pa Electric Motor Factory fitted and installed 3 phase Asynchronous. Induction motor must be installed in the unit and is cooled by a fan who totally enclosed (TEFC) type with 380Volts, 3 Phase, 50 Hz power, class F insulation and IP 54 Fan and motor holder is made of steel and painted to avoid corrosion Coils ezonee coil to the operating room was designed using heat pipe technology that can control temperature (25 ±1) and humidity (55%±5) ezonee coil has won the trophy in ASEAN energy saving award in 2004 for passive heat pipe technology. ezonee coil has been assigned the patent rights ( ID 0 022 403) in Indonesia Filter Section full sealed filter section are designed for easy withdrawal and renewal of filter cells and, are constructed to house any type of primary or secondary filter of different media with various efficiencies. in areas of particular importance, such as hospital and clean room, absolute filter can be provided to ensure safe human an machine environments Tapper Lock Pulley using a type of lock Tapper, we can easily change the rotation of the fan Control Digital thermosta at setting in flexible application range Use AC 803 can be control ON OFF Valve or, AC 8800 can be control motorized Valve with 0 10 Vac

ENGINEERING DATA EAW SERIES (AHU CHILLED WATER)

ENGINEERING DATA EAW SERIES (AHU CHILLED WATER) NO TYPE COIL SIZE (mm) AIR FLOW TUBE PORT TYPE PREFILTER DIMENSI BERAT ROW FRAME EAW Height length CFM INCH IN/OUT CONN 12"x24" 24"x24" (WxDxH)mm KG 1 02S 406.4 500 1188 Ø 3/8" 3 BS Ø 1" DRAT 40 x 40 1 805x775x635 145 2 03S 406.4 750 1780 Ø 3/8" 3 BS Ø 1" DRAT 40 x 40 1 1055x755x635 150 3 04S 406.4 1000 2376 Ø 3/8" 4 BS Ø 1" DRAT 40 x 40 2 1305x755x635 160 4 05S 508 1000 2970 Ø 3/8" 4 BS Ø 1.5" DRAT 40 x 40 2 1305x940x745 180 5 06S 609.6 1000 3560 Ø 3/8" 4 BS Ø 1.5" DRAT 40 x 40 2 1305x940x842 195 6 08S 812.8 1000 4750 Ø 3/8" 4 BS Ø 1.5" DRAT 50 x 50 2 2 1305x1410x1090 210 7 08L 609.6 1333 4750 Ø 5/8" 4 BS Ø 1.5" DRAT 50 x 50 2 2 1755x1370x990 220 8 10S 762 1333 5940 Ø 3/8" 4 BS Ø 2" DRAT 50 x 50 2 2 1650x1390x1040 240 9 10L 762 1333 5940 Ø 5/8" 4 BS Ø 2" DRAT 50 x 50 2 2 1755x1370x1065 235 10 12S 914.4 1333 7128 Ø 3/8" 4 BS Ø 2" DRAT 50 x 50 2 2 1650x1390x1190 320 11 12L 762 1333 7128 Ø 5/8" 4 BS Ø 2" DRAT 50 x 50 2 2 2150x1370x1090 335 12 13S 1016 1333 7722 Ø 3/8" 4 BS Ø 2" DRAT 50 x 50 4 1650x1370x1290 340 13 13L 762 1733 7722 Ø 5/8" 4 BS Ø 2" DRAT 50 x 50 3 3 2150x1370x1090 380 14 15L 838.2 1733 8010 Ø 5/8" 4 BS Ø 2" DRAT 50 x 50 3 3 2150x1370x1140 405 15 18L 1066.8 1733 10692 Ø 5/8" 4 BS Ø 2.5" FLANGE 50 x 50 6 2150x1700x1370 450 16 20L 1143 1733 11880 Ø 5/8" 4 BS Ø 2.5" FLANGE 50 x 50 6 2150x1700x1450 480 17 24L 1371.6 1733 14256 Ø 5/8" 4 BS Ø 3" FLANGE 50 x 50 3 6 2250x1900x1675 520 18 27L 1371.6 1969 16038 Ø 5/8" 4 BS Ø 3" FLANGE 50 x 50 3 6 2500x1900x1675 590 19 30L 1524 1969 17820 Ø 5/8" 4 BS Ø 3" FLANGE 50 x 50 3 6 2500x2000x1825 630 20 35L 1752.6 1969 20790 Ø 5/8" 4 BS Ø 3" FLANGE 50 x 50 9 2500x2000x2055 680 21 40L 1600.2 2500 23760 Ø 5/8" 4 BS Ø 4" FLANGE 50 x 50 5 10 3000x2200x1905 747 22 45L 1828.8 2500 26730 Ø 5/8" 4 BS Ø 4" FLANGE 50 x 50 15 3000x2200x2130 813 23 52L 2057.4 2500 29700 Ø 5/8" 4 BS Ø 4" FLANGE 50 x 50 5 15 3000x2400x2360 1030 NOTE Due to continuing research in energy saving tech, design and specification are subject to change without notice The Cooling capacity is based on the temperature conditions : * cooling coil Air inlet Temp : 27 DB (80 F), 19.5 DB (67 F) * Water Inlet Temp : 6.7 DB (44 F), Water outlet Temp 11.7 DB (53 F), V = 500 fpm * Tube 3/8" * Tube 5/8" 1M² / 3 Row = 120.000 Btu 1M² / 4 Row = 160.000 Btu 1M² / 4 Row = 220.000 Btu 1M² / 6 Row = 200.000 Btu 1M² / 6 Row = 270.000 Btu 1M² / 8 Row = 235.000 Btu 1M² / 8 Row = 310 000 Btu NO UNIT SIZE (mm) TYPE A B C C1 C2 D D1 E F I EAW Height Length 1 02S 635 805 320 242 242 265 175 600 475 775 2 03S 635 1055 320 367 367 265 175 800 475 775 3 04S 635 1305 830 237 237 292 89 1195 475 775 4 05S 740 1305 900 200 200 225 237 1195 600 940 5 06S 842 1305 1040 132 132 305 339 1195 684 940 6 08S 1090 1305 474 415 415 404 193 1195 914 1410 7 08L 990 1650 474 707 574 404 146 1445 789 1370 8 10S 1040 1650 474 682 494 404 196 1445 909 1370 9 10L 1065 1650 474 707 494 404 221 1445 909 1370 10 12S 1190 1650 557 694 399 478 216 1445 990 1370 11 12L 1090 2150 575 797 797 478 114 1785 914 1370 12 13S 1295 1650 557 694 399 478 316 1445 1192 1370 13 13L 1090 2150 557 797 797 478 114 1785 914 1370 14 15L 1140 2150 557 797 797 478 116 1785 940 1370 15 18L 1370 2150 638 756 756 638 228 1785 1210 1700 16 20L 1450 2150 715 718 718 715 199 1785 1250 1700 17 24L 1675 2250 801 725 725 806 237 1885 1510 1900 18 27L 1675 2500 801 850 850 806 237 2025 1510 1900 19 30L 1825 2500 898 801 801 898 245 2025 1625 2000 20 35L 2055 2500 898 801 801 898 475 2055 1856 2000 21 40L 1905 3000 898 1051 1051 898 306 2975 1705 2200 22 45L 2130 3000 1056 1013 1013 1007 385 2975 1930 2200 23 52L 2360 3000 1135 935 935 1135 430 2975 2160 2400 NOTE : S = TUBE Ø3/8" L = TUBE Ø5/8"

SPECIFICATION DATA AIR HANDLING UNIT (AHU) Model EAW - 02 S EAW - 03 S EAW - 04 S EAW - 05 S EAW - 06 S EAW - 08 S EAW - 10 S EAW - 12 S EAW - 13 L EAW - 15 L EAW - 18 L EAW - 20 L EAW - 24 L EAW - 27 L EAW - 30 L EAW - 35 L EAW - 40 L EAW - 45 L EAW - 52 L Btu/h Kcal/h 32512 8194 48768 12290 65024 16387 81280 20484 97536 24581 130048 32774 162154 40865 194584 49038 290017 73089 319019 80398 406024 102325 435026 109634 522031 131560 594150 149735 660166 166373 759191 191328 880110 221802 997793 251460 1136096 286315 Nominal Cooling Capacity *1) Watt TR 9534 2.71 14301 4.06 19069 5.42 23836 6.77 28603 8.13 38137 10.84 47552 13.51 57063 16.22 85049 24.17 93554 26.58 119069 33.84 127574 36.25 153088 43.50 174237 49.51 193597 55.01 222637 63.27 258097 73.34 292608 83.15 333166 94.67 Chilled Water Flow US GPM - LPM 7-27 11-41 14 ~ 55 18 ~ 68 22 ~ 82 29 ~ 109 36 ~ 136 43 ~ 163 64 ~ 244 71 ~ 268 90 ~ 341 97 ~ 365 116 ~ 439 132 ~ 499 147 ~ 555 168 ~ 638 195 ~ 739 221 ~ 838 252 ~ 954 Sensible Heat Factor SHF 0.75 0.75 0.75 0.71 0.71 0.71 0.71 0.71 0.68 0.68 0.68 0.68 0.68 0.68 0.68 0.68 0.68 0.68 0.68 Model Material Casing Color Thickness mm Fin Type Tube Size inch EVAPORATOR Coil FPI - Fin Pitch fpi - mm Face Area m 2 Row Type voltage V/Ph/Hz Fan Motor KW BLOWER & MOTOR Air Flow Ext Static Pressure Connection Water HP Power Input *2) start ampere Run ampere Size Cable Pwr Core x mm ² 2.3 M/s CMH (450 FPM) CFM 2.5 M/s CMH (500 FPM) CFM 2.8 M/s CMH (550 FPM) CFM Pa-(INCH wg ) Piping Type In & Out Size inch Type Condensate Drain Pipe Size inch Allocation Sound Pressure Level db EAW - 02 S EAW- 03 S EAW - 04 S EAW - 05 S EAW - 06 S EAW - 08 S EAW - 10 S EAW - 12 S EAW - 13 L EAW - 15 L EAW - 18 L EAW - 20 L EAW - 24 L EAW - 27 L EAW - 30 L EAW - 35 L EAW - 40 L EAW - 45 L EAW - 52 L Galvanil Steel with Pre Painted Attractive two colour white and blue 1 ~ 3 Super Louver Slit Fined + Plan Tube 3/8 5/8 12-2.1 0.2 0.3 0.4 0.5 0.6 0.8 1.0 1.2 1.3 1.5 1.8 2.0 2.4 2.7 3.0 3.5 4.0 4.5 5.2 4 row Direct Driven-Centrifugal Fan with 3 speed Motor Belt Driven-Forward Curved centrifugal Fan 220 volt / 1 phase / 50 Hertz 380 volt / 3 phase / 50 Hertz 0.3 0.3 0.3 0.8 1.1 1.49 1.49 2.24 4.10 4.10 5.60 5.60 7.46 7.46 11.19 11.19 14.92 14.92 18.65 0.4 0.4 0.4 1 1.5 2 2 3 5.5 5.5 7.5 7.5 10 10 15 15 20 20 25 3.39 3.39 3.39 8.56 12.72 9.79 9.79 14.68 26.92 26.92 36.71 36.71 48.94 48.94 73.42 73.42 97.89 97.89 122.36 1.7 1.7 1.7 4.3 6.4 4.9 4.9 7.3 13.5 13.5 18.4 18.4 24.5 24.5 36.7 36.7 48.9 48.9 61.2 4 x 2.5 4 x 4 4 x 6 4 x 10 1,679 2,518 3,358 4,197 5,037 6,715 8,373 10,048 10,891 11,981 15,248 16,337 19,605 22,313 24,792 28,511 33,052 37,472 42,666 988 1,481 1,975 2,469 2,963 3,950 4,925 5,910 6,407 7,047 8,969 9,610 11,532 13,125 14,584 16,771 19,442 22,042 25,097 1,865 2,798 3,731 4,663 5,596 7,462 9,304 11,164 12,102 13,312 16,942 18,152 21,783 24,792 27,547 31,679 36,725 41,635 47,406 1,097 1,646 2,195 2,743 3,292 4,389 5,473 6,567 7,119 7,830 9,966 10,678 12,813 14,584 16,204 18,635 21,603 24,491 27,886 2,052 3,078 4,104 5,130 6,156 8,208 10,234 12,281 13,312 14,643 18,637 19,968 23,961 27,271 30,302 34,847 40,397 45,799 52,147 1207 1811 2414 3018 3621 4828 6020 7224 7830 8614 10963 11746 14095 16042 17824 20498 23763 26940 30675 150-(0.6) 150-(0.6) 150-(0.6) 150-(0.6) 150-(0.6) 150-(0.6) 150-(0.6) 254-(1") 254-(1") 254-(1") 254-(1") 381-(1.5") 381-(1.5") 381-(1.5") 381-(1.5") 381-(1.5") 381-(1.5") 381-(1.5") 381-(1.5") 50 1" 53 On The Floor/ Hangging Male Piping Thread 54 55 55 56 57 Male Piping Thread FLANGE JIS K10 kg 1.5" 2" 2.5" 3" 4" 3/4" 1" 60 62 On The Floor 63 65 67 68 69 68 69 70 70 73 Notes : Due to continuing research in energy saving technology, design and specification are subject to change without notice. The cooling capacity is based on the temperature conditions: *1) Cooling Coil Air Inlet Temperature : 27 C DB (80 F DB), 19.5 C WB (67 F WB) H Water Inlet Temperature : 6.7 C (44 F) - Water Oulet Temperature 11.7 C ( 53 F) *2) Current running ampere depend on ESP & Condition at site *3) Above Dimension Standart Unit, and We can make also Customize Unit - We can Up Number of Row and Static Pressure Unit W D

17 C 20 C 17 C 20 C ENGINEERING DATA SINGLE WIRING DIAGRAM for EAW 02, EAW03, EAW 04, EAW 05, EAW 06, ROOM BAS SINGLE WIRING DIAGRAM for EAW 08, EAW 10, EAW 12, EAW 13, EAW 15, EAW 18, EAW 20, EAW 24, EAW 27, EAW 30, EAW35, EAW 40, EAW 45, EAW 52 ROOM BAS MODEL EAW 02S 03S 04S 05S 06S 08S 08L 10S 10L 12S 12L 13S 13L 15L 18L 20L 24L 27L 30L 35L 40L 45L 52L A 4A 6A 10A 6A 10A 16A 25A 32A 50A 60A 75A B 4X2.5mm 4x4mm 4x6mm 4x10mm

CONTROL TYPE AC 803, AC 8800, AC 8800+TN 1. OPERATION CONDITION Power Supply : 220Vac ± 10%, 50/60Hz Comsumption : < 1.5W Load Current : < 2A Accuracy : ± 1 C Set Point Range : 10 C 30 C Timming Error : < 1% Output Comsumption : < 200 W Size ( L x W x T) : 86 x 86 x 12mm 2. FEATURES Control Room Temperature 1 Stage compressor/ Valve 3 Speed Fan & Auto Display Digital Setting & Room temperature Mode Hot & cool Easy operation Timing ON/OFF Automatic 1 RS 485 communication ports Thermostat AC 8800+TN