Weighing Systems. Batch Dump. Acrison. for reliable and accurate batch weighing applications. Model 403B (D) Series

Similar documents
Acrison. Volumetric Feeders. Model 1015 Series. For Dry Solid Materials

WEIGH FEEDERS Models 402 and 404 Series, 405 and 406 Weight-Loss-Differential

Acrison. Volumetric Feeders. Models BDFM, BDF-1, BDF-1.5 BDFX-1.5 and BDFX For Dry Solid Materials

Acrison Volumetric Feeders

BD SERIES BLENDERS Batch Weigh Blenders

E SERIES Net weigh scale and manual bagger

Flo-Way. Measure Granular or Powdered Material. Stand Alone or Connect to Other Devices for Blending. Used by Successful Producers World-Wide

S-SERIES DISPLACEMENT TRANSDUCERS

E SERIES Net weigh scale and manual bagger

Fully Automated Standard Dispensers

CB50X & CB50X-DL load cells Influence factors in weighbridge application

Electronic Control Valves

INTERCONNECTION STANDARDS FOR PARALLEL OPERATION OF SMALL-SIZE GENERATING FACILITIES KILOWATTS IN THE STATE OF NEW JERSEY

ON-BOARD SCALES. ON-BOA R D WEIGHING S O LUTIONS F O R THE R E FUSE INDUSTRY

polymer Blending As-supplied or Concentrated Polymer Polymer is a long chain Effects of Insufficient Mixing Energy When insufficient

three different ways, so it is important to be aware of how flow is to be specified

The Worldwide Leader in Concrete Paving Technology

.3 Section Waste Management and Disposal.

Belt-Way Integrator Features

BAC2000ind.

Belt Scales Table of Contents

LOSS-OF-WEIGHT _ Systems Installation and Operating Instructions

MSI SINGLE IDLER BELT SCALE

Figure 1 Linear Output Hall Effect Transducer (LOHET TM )

Automotive Sensor Products

Dry Chemical Feed Systems

Volumetric Feeders, AccuRate Series

White Paper. Ground Fault Application Guide. WL Low Voltage Power Circuit Breakers

Specification Guide. for RMAX. Direct Replacement. AC Low Voltage. Power Circuit Breakers

Feeder Types Selection & Operation BSH&E SEMINAR

fact sheet Masoneilan * 8012/8013 Series Electro-pneumatic Valve Positioners GE Oil & Gas Excellent Dynamic Response and Positioning Accuracy

SERIES Pulse and 12 Pulse DC Power Supplies for Electrocoating and Industrial DC Powered Systems MODELS 506 & 5012

SWC515 PinMount. Right the First Time Safe, Accurate, Service Friendly. SWC515 PinMount. Right the First Time

SWB505 MultiMount. Right the First Time Safe, Accurate, Service Friendly. Right the First Time

USER'S MANUAL MODEL DPS32PG1 DRIVER PACK

80V 300Ah Lithium-ion Battery Pack Data Sheet

Instruction Manual August milltronics MMI BELT SCALE

POSITIONERS and Controls for Complete Valve Automation

VERTICAL FORM FILL SEAL MACHINES

Volumetric Feeders, AccuRate Series

SWB505 MultiMount. SWB605 PowerMount. Right the First Time Safe, Accurate, Service Friendly. Right the First Time

Internal Luggage Scale

CHAIN WEAR ANALYSIS WITH LUBECON

ni.com Sensor Measurement Fundamentals Series

w w w. m a r v e l s a w s. c o m

ULTRAFLO 2000 ULTRASONIC LIQUID FLOW AND HEAT/ENERGY METERS FOR PERMANENT INSTALLATION HIGH TEMPERATURE SENSORS AS STANDARD

Designed for Right-Side and Left-Side Pour

AX900 AXLESCALESERIES

INTERCONNECTION STANDARDS FOR CUSTOMER-OWNED GENERATING FACILITIES 25 kw OR LESS PUBLIC UTILITY DISTRICT NO. 1 OF CHELAN COUNTY

Sentinel. Panametrics Custody Transfer Gas Ultrasonic Flowmeter. GE Sensing. Applications. Features

BorgWarner s growing hybrid and electric product portfolio delivers clean, efficient vehicle propulsion

Platform-Mounted packing & loading plant

UNITIZED batching INSTaLLaTION guide

ILE - 61 SENSING HEAD

i n t e g r a t e d i n n o v a t i o n

Accutrol, LLC Product Sheet. VTS Series. US Patents 6,991,177 & 7,543,759. Digital Airflow Measurement Station

MoistureMatch A next generation grain tester

Process Industry. Diaphragm Seal Solutions

Cardinal Scale Armor model EPR electronic truck scale with optional guide rails. Bulletin No. 295G

Power Feed 10R. Compact Wire Drive System for Automation. Processes. Description. Recommended General Options. Advantage Lincoln

Instruction Manual August milltronics MSI BELT SCALE

Weigh Module. Selection Guide.

CPC DX (CPC Dual Transfer Skid) Redundant current to pressure converter assembly

Cemco Central Mixer. Sales Specification Sheet. Quality of Concrete and Design. Basic Overview

Accurate, versatile chemical pumps

COIL WINDING TECNHOLOGY LINE. Advanced High-Tech Solutions for Coil Winding Process Control

Modeling Contact with Abaqus/Standard

SALIENT FEATURES OF K.MASS TEST BENCHES

kyalfa Laval Weighing Systems UltraPure with digital beam load cell

HYBRID POWER FOR TELECOM SITES

Product Manual (Revision C) Original Instructions. Air/Fuel Ratio Control. Installation and Operation Manual

Dynamic Adjustment Procedure for 700-series Digital Controls. Application Note (Revision A,8/1998) Original Instructions

L E V E L P L U S M - S E R I E S ANALOG

GULLIVER Horizontal Paddle system mixer-feeders

Electrical Press Brake

Sentinel Panametrics Custody Transfer Gas Ultrasonic Flowmeter

VOLUMETRIC BLENDING SYSTEM OPERATION MANUAL

Controls, Tell-tales, Indicators and Sources of Illumination

CONTROL VALVES QUALITY, DEPENDABILITY, SERVICE. REPUTATION BUILT ON. Innovative Solutions

MILLTRONICS UNIVERSAL SCALE NIVERSAL SCALE Rev. 1.2

Accutrol, LLC Product Sheet AVC6000. US Patents 6,991,177 & 7,543,759. Laboratories, Life Sciences, Healthcare

Accutrol, LLC Product Sheet AVT6000. US Patents 6,991,177 & 7,543,759. Laboratories, Life Sciences, Healthcare

CPW Current Programmed Winder for the 890. Application Handbook. Copyright 2005 by Parker SSD Drives, Inc.

LIQUID MEASUREMENT STATION DESIGN Class No

Ton-Tel Multi-Deck Weighbridge

SMARTLINK METER. Digital Self-checking Thermal Mass Flow Meter

AUTOMATIC LUBRICATION

AVL FUEL BALANCE & FUEL TEMPERATURE CONTROL

Wagner Instrumentation

Technical Data. Series Oval Flowmeter. Model 9400

Inline Ultrasonic Flowmeter

SURVIVOR Paramounts HE Medium-Capacity Weigh Module Systems

Ultra Compact UHP Liquid Flow Controllers

Instruction. MI June E69F Current-to-Pneumatic Signal Converter

0 to 100 up to 0 to PSI (gage) Packard Electric Metri-Pack 150 Series, M12-4 Pole* 1/4-18 NPT ma, VDC, 0-5 VDC, 0-10 VDC

Truck Scale Description

kyhygienic and reliable weighing solutions for your process

Acid Resistant AVC6000

HC2 Three-Axis Helmholtz Coil

MAILCRAFTERS. MAILCRAFTERS Products of Inscerco Mfg., Inc. THE ULTIMATE CHOICE IN COMPUTERIZED INSERTING TECHNOLOGY

Transcription:

R Acrison Batch Dump Weighing Systems / Bulletin 840 for reliable and accurate batch weighing applications Model 403B (D) Series Quality built, total performance products to satisfy your dry solids metering/handling needs.

Model 403(D)Series Batch/Dump Weighing Systems with BATCH-LOK for disturbance-free operation Introduction The Model 403B(D) Batch/Dump Weighing System basically consists of a hopper (for dry solids) or a tank (for liquids) integrally mounted onto an Acrison Overhead type weighing (scale) system, specifically designed for highly reliable and accurate batch-weighing applications. For dry solids applications, product is typically fed into the scalemounted hopper (weigh hopper) by an Acrison Volumetric Feeder (see page 3). When it is required to batch weigh more than one product in a single weigh hopper, each material is individually (sequentially) batched, since only one ingredient can be batch weighed at a time. Regardless of the physical handling characteristics of the dry solid ingredient, Acrison s wealth of experience in this very specialized industry, in combination with the totally digital system capability of the various Model 403B(D) Batch/Dump Weighing Systems, provides a truly viable solution for your batch weighing requirements. Model 403B(D) Batch/Dump Weighing Systems boast a permanently calibrated, non-load cell based, high resolution, lever weighing network encompassing a totally rugged industrial design. These remarkably precise weighing systems are also unaffected by temperature extremes, typical in-plant vibrations, and are calibration and adjustment-free (please see page 4 for additional information). The various Acrison controllers available for use with Model 403B(D) Batch/Dump Weighing Systems include a unique and proprietary feature Batch-Lok which ensures accurate batch weighing should the weighing system detect an abnormal disturbance during the batch weighing cycle. Also available is an assortment of control schemes from a simple single ingredient batch weighing controller to a multi-ingredient batch weighing control system. The many variations and overall capabilities of the various Model 403B(D) Batch Weighing Systems are too numerous to outline in a basic brochure. Let our staff of experienced application engineers recommend the equipment that will best satisfy your specific requirements. Beyond our engineering staff, our award-winning, fully equipped Customer Demonstration Facilities are available to physically test and/or demonstrate our various batch weighing capabilities. Highest Performance, Quality, Longevity and Value Batch Size (weight): 250 grams to tons per batch. Batch Accuracy: ± 0.1 to 0.5 percent or better (error) at two sigma, based on a given number of consecutive batch weighments. To ensure this accuracy, the batch weight must not be more than one-thirtieth the scale capacity. Batch Weight Range (standard): 30:1 turn-down from the scale capacity. Scale Resolution: one part in 1,048,576. Ambient Temperature Operating Range: -10 to 140 F. Scale Design: High resolution, frictionless, counterbalanced lever network utilizing stainless steel flexures for all pivotal connections. The non-load cell based weighing system is extremely rugged and durable, and is both calibration and adjustment-free. See page 4 for details. Batch Frequency: Depends on application; consult Acrison. Metering Mechanisms for feeding dry solids into a Model 403B(D) Weigh Hopper: A wide range of models is available. Selection is dependent upon the physical handling characteristics of the product or products. Model 403B(D)-10 2

Model 403(D) Batch/Dump Weighing Systems for Dry Solids A typical multi-ingredient Model 403B(D) Batch/Dump Weighing System utilizing Acrison volumetric feeders to meter dry solid products into the Weigh Hopper PRODUCT A PRODUCT B PRODUCT C Volumetric Feeder Volumetric Feeder Volumetric Feeder BATCH/DUMP WEIGH HOPPER Model 403B(D)-3 Automatic Discharge Valve Selection Batch/Dump (single ingredient) metering into a Model 403B(D) Weigh Hopper to a preset weight, and then discharge the entire contents on command. Batch/Dump (multi-ingredient) metering (sequentially) into a Model 403B(D) Weigh Hopper to individually preset weights and then, discharge the entire contents on command. With a Batch/Dump arrangement, the total weight or amount of a given batch is normally encompassed within the weigh hopper. Therefore, the weigh hopper must be designed to hold the entire amount of the largest desired total batch, unless multiple batches are preferred. For the various Acrison volumetric feeders that may be used in conjunction with Model 403B(D) Dump Weighing Systems, please reference Bulletins 270, 712, and Data Specs 1-200-0479, 1-200-0481, 1-200-0480, 1-200-0525. NOTE: For a liquid system, the dry solids weigh hopper is replaced with a weigh tank and the dry solids feeders (metering into the Batch/Dump Hopper) are replaced with either valves or pumps. Model 403B(D)-20 3

Model 403(D)Series Batch/Dump Weighing Systems Secondary Flexures (2) Linkage Flexures (2) or (4) All-Flexure Weighing System with Acrison s exclusive Ratiometric Digital Weight Resolver Weigh Hopper (or Tank) Automatic Discharge (Dump) Valve Primary Flexures (2) Linkage Arm(s) Counterbalance Weight DRY SOLIDS SYSTEM ILLUSTRATED Main Structure NOTE: For liquid units, the dry solids weigh hopper is replaced with a tank. Principal Lever Beam Ratiometic Digital Weight Resolver Dashpot Acrison s overhead type weighing mechanism, used with Model 403B[D] Batch/Dump Weighing Systems, is a frictionless, mechanically counterbalanced, modified parallelogram type lever network (scale), utilizing Acrison designed and manufactured flexures for all connecting (pivotal) requirements. These novel, time-proven stainless steel flexures provide optimum structural rigidity of the lever network, both in the horizontal and vertical planes. As noted in the illustration, two primary flexures connect the principal lever beam to the main support structure, with two secondary flexures connecting the actual weigh hopper (or tank) to the principal lever beam. A single or dual linkage assembly, utilizing either two or four flexures, connects the lower portion of the weigh hopper (or tank) to the main structure. The permanently calibrated, non-load cell Model 403B(D) Weighing System is simple, very durable, and extremely precise in producing unexcelled resolution. As weight is added to, or subtracted from, the weigh hopper(or weigh tank), the lever network moves in an extremely precise relationship to that weight. In turn, this movement is sensed by Acrison s Ratiometric Digital Weight Resolver, instantaneously converting this movement into an equally precise signal directly proportional to weight. In differing from the common variety of load cell based batch weighing systems, the physical sensing element of Acrison s Ratiometric Weight Resolver does not attach to the lever (or scale) network and therefore, cannot be damaged by any amount of overload, shock and/or abuse that the weighing system may experience. In addition, the Model 403B(D) Weighing System does not require calibration or adjustment. The entire weighing mechanism, including the weight sensing system, is completely calibration and adjustment free, and guaranteed for five years. 20 Bit Digital Output Ratiometric Digital Weight Resolver System Non-Contacting Coupling Element Ratiometric Digital Weight Resolver System Logic Exciter Element Scale Digital Weight Resolver (Sensor) Acrison s Ratiometric Digital Weight (Resolver) Sensing System, used with all Acrison weigh feeders, computes the linear movement of the frictionless lever mechanism (scale) into a true binary coded, serially transmitted data stream, having a discrete resolution of 20 bits (or the ability to sense 1 part in 1,048,576). This highly precise and advanced electronic displacement measuring technique basically consists of a sensing element and its computational logic. The physical sensing element is composed of a series of windings collated on a common element that are equally affected by environmental changes and therefore, selfcompensating. In addition, because the computational logic of the Ratiometric Digital Weight Sensing System compares relative measurements, rather than absolute values, its input power source can vary up to ± 30% without affecting the output. Also, all non-weight data, both cyclic and random in nature that may be super-imposed on the actual data, are cancelled-out. The Ratiometric Digital Weight Sensing System is linear to within 0.01 percent, repeatable to 0.005 percent, possesses long term stability of 0.005 percent (10,000 hours) and carries a 40,000 hour MTBF. Acrison s Ratiometric Weight Sensing System is FM (Factory Mutual) Approved and Listed for operation in hazardous environments Classes I, II and III; Divisions 1 and 2; Groups C, D, E, F and G. This weight sensing system also complies with European hazardous area classifications EEx ia IIB T4 and EEx d [ia] IIB T6. 4

Weigh Feeder Controllers and Control Systems Acrison weigh feeder controllers are recognized worldwide for their innovative, flexible designs and highly dependable performance. Available with a number of different keyboard/displays, including color touchscreens, these controllers operate Acrison weigh feeders in the continuous or batching mode, control volumetrically or gravimetrically, and include provisions for master/slave and ratio/proportioning operation. Their many unique features provide optimum operational flexibility, and allow a wide variety of packaging possibilities. In addition, Acrison controllers include provisions for an exceptionally broad range of I/O interfacing options (i.e., analog, frequency, digital, BCD, Modem, serial and network I/O). Acrison also offers AD 2000, a Supervisory Control System (software) for the control and monitoring of up to 32 Acrison controllers. (Design Specifications 1-200-0602 and 1-200-0627) SBC-2000 Weigh Feeder Controller The SBC-2000 Weigh Feeder Controller has been designed as a single, small module for use in a variety of applications, particularly those that require central computer control and minimal hardware, and which do not necessarily require a local user interface or keyboard/display. The technologically advanced design of the SBC-2000 provides very broad operational flexibility; it is also available with various keyboard/displays. (Design Specifications 1-200-0601) MD-II 2000 Weigh Feeder Controller The MD-II 2000 Weigh Feeder Controller has been designed for use with any of Acrison s various model weigh feeders in a variety of applications. As standard, the MD-II 2000 is furnished with a graphic display capable of displaying messages in a choice of languages. Optionally, it is available with a color touchscreen/display. (Bulletin 949 and Design Specifications 1-200-113) MD-II MFC Weigh Feeder Controller The MD-II MFC is a state- of- the-art Multi-Feeder Controller offering unequalled ease of operation by means of a unique operator friendly graphic color touchscreen display. Capable of controlling up to 16 Acrison feeders, the MD-II MFC provides rapid feeder and screen updates and recipe storage and retrieval, all of which are selectable and operable from the controller s touchscreen/display (available in several different sizes). (Design Specifications 949 and 1-200-342) Acrison Weigh Feeder Controllers carry standard certification to UL, CSA and CE specifications. Weigh Feeder Controller MD-II 2000 CTS 5

Discover the difference! We cordially invite you to witness a test in Acrison s state-of-the-art Customer Demonstration Facilities handling your actual product(s) with the specific equipment we recommend for the application. Usually, there is no cost or obligation for this service. Discover the difference in technology, quality and performance of Acrison equipment. Acrison products Models 101 and 130 Volumetric Feeders Models V101 and V130 Volumetric Feeders Model 1015 Volumetric Feeder Series Model 105 Volumetric Feeder Series Model W105 Volumetric Feeder Series Model 120 Volumetric Feeder Model 140 Volumetric Feeder Series Model 170 Volumetric Feeder Series Model 200 Series of Weigh Belt Feeders Model 203B Series of Weigh Auger Feeders Model 270 Series of In-Line Weigh Feeders Models 402, 404, A405, 406 and 407 Series ( Weight-Loss-Differential ) Weigh Feeders Model Series 403 ( Weight-Loss-Differential ) Weigh Feeders Model 403B(D) Batch/Dump Weighing Systems Model 404BZ(BU) Bulk Bag Unloader Batch Weigher Models 350 and 301 Continuous Blenders and Blending Systems Multiple Auger Bin Dischargers and Multiple Auger Bin Discharger Hoppering Systems Multiple Auger Bin Discharger Feeders Vibratory Bin Dischargers Model 500 Series of Polyelectrolyte Preparation Systems Water and Waste Water Treatment Systems Volumetric and Gravimetric Feeder Controllers and Control Systems Accessory Equipment for Acrison Products Systems Engineering Visibly Different Measurably Better Acrison 20 Empire Blvd. Moonachie, NJ 07074 USA 201-440-8300 Fax: 201-440-4939 Email: informail@acrison.com Website: www.acrison.com 300-0019/E/ 2-03/7006 Copyright 2003 Acrison, Inc. all rights reserved. Acrison is a Registered Trademark of Acrison, Inc., Moonachie, New Jersey Registered Acrison Trademarks Domestic and Foreign Patents issued and pending.