Veterinary Anesthesia Gas Scavenging System (Active)

Similar documents
Canis Major Wet Dental / Treatment Lift Table. For models: CMDT-45 CMDT-WS-45 CMDT-60 CMDT-WS-60. User s Guide Rev. AA2 7/13/18.

Veterinary Scavenger Interface

Podiatry Procedures Chair. For Models: Barrier-Free. User s Guide

Power Procedures Table

RANGE HOODS USER INSTRUCTIONS

HATCHGRIP Installation Instructions/Operation and Maintenance Manual

Installation Instructions

Installation Instructions

AUTOMATIC SUBMERSIBLE UTILITY PUMP

Installation Instructions

Installation Instructions

Installation Instructions

Installation Instructions

Installation Instructions

Installation Instructions

Installation Instructions

PART NUMBER: F-706RLSS REVOLUTION LIFT: SLING-SEAT OPTION

Users Guide for Ac-sync

HR-20P Pneumatically Controlled Pressure Regulator

Installation Instructions

DAP-625S and DAP-875S

SUBMERSIBLE SUMP PUMPS

GA-160 Gas Amplifier

SEWAGE PUMP MODEL # Zoeller is a registered trademark of Zoeller Co. All Rights Reserved. Español p. 14

GRINDER PUMP MODEL # Zoeller is a registered trademark of Zoeller Co. All Rights Reserved. Español p. 13

Installation Instructions

MEX (55) QRO (442) Web Controls

Installation Instructions

SUBMERSIBLE SUMP PUMPS

Model T2642 Wall Mount. Television Wall Mount with Tilt Option

Installation Instructions

Model AS-FM64 Wall Mount. Full Motion Television Wall Mount

Owner s Manual & Safety Instructions

INSTALLATION & OPERATING INSTRUCTIONS: REVOLUTION SPINEBOARD ATTACHMENT WARNING

2SHE Series Direct-Drive Shutter Fans

Model FM2642 Wall Mount. Full Motion Television Wall Mount

Installation Instructions

Installation Power Management Unit Battery Cables and Battery Harness

INSTRUCTION MANUAL. Rotary Unidirectional Piezoelectric Motor Evaluation Kit. (Model: UPM-28) Made in USA

NEUTRALIZATION SYSTEM FOR OPA & GLUTARALDEHYDE MEDI-NEWT. User Manual. Endoscope reprocessing the the way way it it should be be

END USER TERMS OF USE

1250 LB. CAPACITY MECHANICAL WHEEL DOLLY

Straight-Bore Clutch LSCC-32, 44, 54

INSTALL GUIDE Dodge/RAM 5.7L HEMI

PUMP SPY INSTALLATION AND OPERATING INSTRUCTIONS

14", 18" & 24" Fiberglass Turbo Fans Installation & Operator s Instruction Manual

PRE-PLUMBED SEWAGE SYSTEM

Operator s Manual. Automatic Electric Jack Leveling. The leveling system shall only be operated under the following conditions:

7.3L POWERSTROKE BANJO BOLT KIT Fits L Powerstroke Diesel. Installation Guide

VANGUARD Series 36" Slant Wall and Cone Direct Drive Fans Installation & Operator s Instruction Manual

60 PSI Boost Gauge. For Product Numbers: MT-DV01_60, MT-WDV01_60

Linear Actuator. Installation Manual. warranty installation parts list. Linear Actuator Installation Manual Page 1

Power. On Your Terms.

PEDESTAL SUMP PUMP. MODEL # Español p. 11. Zoeller is a registered trademark of Zoeller Co. All Rights Reserved.

10 Year Limited Warranty

DUAL WIDEBAND AIR/FUEL RATIO GAUGE Product Numbers: GS-W702W_Dual, GS-C702W_Dual, GS-T702W_Dual

Illumifalls Patio Pond

Model AS-RC3260 TV Cart. Rolling Cart for Audio Mount System & Flat Panel TVs

Type Maxi Mix III Rotary Shaker

Part Number Mini Linear Lift Assembly Installation & Operator s Instruction Manual

PVI 1800/PVI Residential/Commercial Grid-Tied Photovoltaic Inverter WARRANTY MANUAL. Subject to Change REV , Solectria Renewables

Submersible Pond Pump with UV 800 Gallons Per Hour

OWNER'S MANUAL. Royal Sovereign International Inc. RET Desk Series

Premium Pond Pump 330 Gallons Per Hour

OWNER S GUIDE 8A DURALIFT II 13,200 LB. CAPACITY. Link Mfg. Ltd th St. N.E. Sioux Center, IA USA

Submersible Waterfall Pump 1200 Gallons Per Hour

Dual/Triple Manifold Water Filtration Systems Instruction Manual

User s Manual and Operating Instructions

LUBRICATOR GUN INSTRUCTIONS-PARTS LIST. 10,000 psi (700 bar) Maximum Delivery Pressure. Detachable-type

Instruction Sheet EWR SERIES EWR WALL CABINET R

Read and follow all instructions. Safety can only be ensured if the walker is assembled and operated according to these instructions.

User Guide IGD Series

Operation Manual. 355 Lighting System. Safety 2. Features 4. Component Overview 5. Controls & Indicators 6. Operation 7.

DeZURIK 2 20" BOS BUTTERFLY VALVES


Barrier-Free Bariatric Power Treatment Table

Lubricator Gun: 10,000 psi (700 bar) Maximum Delivery Pressure when disconnected from Dispenser

XLR-IR850 Long-Range Infrared Illuminator

INSTALLATION INSTRUCTION & OWNER S MANUAL

Operators Manual OC6000 & OC6200

Model 90 Twin Control Unit

GC-1. Roof and Gutter De-Icing Control Installation and Operating Instructions FOR EXTERIOR INSTALLATION ONLY

Fitting Instruction for EZI-GRIP Bike Rack

Container Fountain Kit with LED Light

Through-Shaft Clutch-Brake LSCB-32HT, LSCB-32HT, LSCB-44, LSCB-44HT, LSCB-54HT FORM NO. L D-0606 MEX (55) QRO (442)

FLEETWOOD TRAVEL TRAILER SLIDEOUT SYSTEM OWNER S MANUAL

idrive Power Cord Extender Installation Instructions MODELS: 3960M/3961S (1) 25 POWER CORD DRILL WITH 3/32 DRILL BIT

ASSEMBLY / OPERATION INSTRUCTIONS. Low Profile Motorcycle Dolly

ESE Series Cast Iron Sewage Pumps

DUSTTRAK AEROSOL MONITOR SOLAR POWER KIT MODEL

APCO CRF-100A RUBBER FLAPPER SWING CHECK VALVES

Automatic Emergency Light

GORE TRAILER MANUFACTURING INCORPORATED 305 Gore Trailer Road Whiteville, North Carolina 28472

Installation & Operators Manual

Broadband PowerShield. External Battery Pack 20 Ah 12 V Battery. User Manual

Swing Arm Magnifying Lamp

IAQ-CALC INDOOR AIR QUALITY METER MODEL 7515

CRD610 Automatic Fitting Inserter

Flo-Way. Measure Granular or Powdered Material. Stand Alone or Connect to Other Devices for Blending. Used by Successful Producers World-Wide

MaxLite StaxMax LED Flood Lights

Transcription:

Veterinary Anesthesia Gas Scavenging System (Active) Installation and Operation Manual MX103200i 10434800 Rev. AA1 5/5/17

Table of Contents Section 1 UNPACKING...2 1.1 Examining Packaged Components...2 Section 2 DESCRIPTION & IDENTIFICATION...3 2.1 About the System... 3 2.2 About your Components... 3 Section 3 INSTALLATION... 5 3.1 Getting Started...5 3.2 Installing the Gas Disposal Vent Kit... 5 3.3 Installing the Scavenger Interface... 6 3.3.1 Wall Mount...6 3.3.2 Post Mount... 7 3.4 Installing the Scavenger Interface Tubing... 7 Section 4 OPERATION...8 4.1 Operating your Anesthesia Gas Scavenging System (Active)... 8 4.2 Tips for Optimal Scavenger Interface Performance... 8 Section 5 MAINTENANCE... 9 5.1 General Cleaning and Replacement... 9 5.2 Periodic Maintenance... 9 5.3 Troubleshooting Guide...9 5.4 Replacement Parts... 10 Section 6 INFORMATION & WARRANTY... 11 6.1 General Information... 11 6.2 Return Goods Procedure... 11 6.3 Warranty... 11 Illustrations & Charts Figure 1 Packaged Active Scavenger Interface Components... 2 Figure 2 Anesthesia Gas Scavenging System Configuration Options...4 Figure 3 Gas Disposal Vent Location... 5 Figure 4 Wall Mounting Scavenger Interface Bracket Mounting... 6 Figure 5 Post Mounting Scavenger Interface Bracket Mounting...7 Figure 6 Interface ON / OFF Switch...8 Figure 7 Periodic Maintenance Chart... 9 Figure 8 Cleaning Interface Vents... 9 Figure 9 Troubleshooting Chart... 10 Figure 10 Replacement Parts Exploded View... 10 Safety Symbols WARNING Indicates a potentially hazardous situation which could result in serious injury if not avoided. CAUTION Indicates a potentially hazardous situation which may result in minor or moderate injury if not avoided. It may also be used to alert against unsafe practices. Equipment Alert Indicates a potentially hazardous situation which could result in equipment damage if not avoided Note Amplifies a procedure, practice, or condition. 1

OFF Section 1 UNPACKING 1.1 Examining Packaged Components Step 1: Step 2: Examine the shipping carton for external shipping damage. Remove content from each plastic bag and examine for visible damage. Note: Contact shipping company immediately if any damaged or broken parts are discovered. Step 3: Inspect and inventory components (in individual plastic bag) as shown in illustration below. Note: Notify your Matrx by Midmark dealer representative if any parts are missing. ON H I A B D C E F G K L J N M P OR W O Q V X R S T U Y Z AA Item Quantity Description A 1 Interface Assembly B 1 Interface Installation Manual C 1 Wall Plate D 1 Tube Clamp E 1 1.25 Worm Gear Clamp F 1 #10 Wood Screw G 1 Gas Disposal Subassembly H 1 Gas Disposal Installation Instructions I 1 Scavenger Hose Suspension Installation Instructions J 8 Cable Tie K 2 1.25 Worm Gear Clamp L 1.5 Worm Gear Clamp M 8 Cable Tie Holder Refer to page 11 for Replacement Part Number Identification Figure 1. Packaged Active Scavenger Interface Components 2 MX104600i Item Quantity Description N 8 #6 Screw O 20 ft. 32mm Magenta Tubing P 1 Post Mount Installation Instructions Q 5 ft. 19mm Magenta Tubing R 1 Interface Mounting Bracket S 2 U-Bolt T 4 1/4 Nut U 4 1/4 Flat Washer V 18 ft. 19mm Magenta Tubing W 1 Wall Mount Installation Instructions X 2 ft. 32mm Magenta Tubing Y 2 1/4 Flat Washer Z 2 1/4 Nut AA 1 Interface Mounting Bracket

Section 2 DESCRIPTION & IDENTIFICATION 2.1 About the System This veterinary anesthesia scavenging system is intended for veterinary use only. It is not intended for use in health care facilities that provide services to human beings. This device is not intended for use with flammable anesthetics. Installation of this device and its components in a veterinary operatory should be made by competent individuals. The Matrx by Midmark Veterinary Anesthesia Gas Scavenging System (Active) is a device that captures excess anesthesia gas from the anesthesia machine and disperses it to the outside of your facility. This system can be used with any Matrx by Midmark Anesthesia Machine or with comparable machines. The Matrx by Midmark Veterinary Anesthesia Gas Scavenging System (Active) can also be used with an extracorporeal oxygenator. 2.2 About your Components This Matrx by Midmark Veterinary Anesthesia Gas Scavenging System (Active) incorporates the following components with some supplied in individual kits (*). SCAVENGER KIT: The scavenger interface provides positive and negative pressure relief, provides reservoir capacity, and directs the collected gas to the Gas Disposal Vent through the disposal tubing. The interface may be mounted to either the Anesthesia Machine s base post or an exterior wall. WARNING This devise is not intended for use with flammable anesthetics. CAUTION This devise will exert pressures between atmospheric pressure and -0.5 cm-h 2 O on an oxygenator gas vent. Compatibility must be checked. MOUNTING KIT (*): The Mounting Kit enables you to mount the interface to either a post or to an exterior (outside) wall. Refer to Figure 2 for an illustration depicting both of these mounting configurations. GAS DISPOSAL KIT (*): The Gas Disposal Kit is designed to mount through an exterior wall of a building and to disperse the anesthetic gas from your anesthesia machine to a disposal point that is normally isolated from personnel, doors, windows, and any air intake(s) or outlet(s). WARNING Do not install the Gas Disposal Kit through the ceiling or roof. TUBING KIT (*): TRANSFER TUBING The Transfer Tubing fastens to the outlet tube of the Gas Collecting Assembly (APL valve) on your Anesthesia machine and the input port on the Active Scavenger System Interface, which is located on the bottom of the interface. The Transfer Tubing is 19mm in diameter and magenta in color. CAUTION Do not clamp the transfer tubing to the APL valve. Do not allow the transfer tubing to run along the floor. DISPOSAL TUBING The Disposal Tubing is 32mm in diameter and is also magenta in color. The Disposal Tubing fastens between the outlet (downstream) opening which is located on top of the interface and the Gas Disposal Vent. 3

Section 2 DESCRIPTION & IDENTIFICATION (cont.) 2.2 About your Components (cont.) Post Mount Post Mount Tubing Kit Components Total Tubing From Anesthesia Machine to Exterior Wall Can Not Exceed100 Ft. Anesthesia Machine (not included) Gas Disposal Kit Components Active Scavenger System Interface Components (post mounted) Exterior Wall MX103200i Wall Mount Total Tubing From Anesthesia Machine to Exterior Wall Can Not Exceed100 Ft. Wall Mount Tubing Kit Components Gas Disposal Kit Components Anesthesia Machine (not included) Active Scavenger System Interface Components (wall mounted) Exterior Wall MX103300i Figure 2. Anesthesia Gas Scavenging System Configuration Options 4

Section 3 INSTALLATION 3.1 Getting Started Check the location you have selected to install your Gas Disposal Vent carefully to make sure it meets all safety requirements as explained in the Instructions. The kits and components should be installed in the following order: Gas Disposal System Scavenger Interface Tubing 3.2 Installing the Gas Disposal Vent Kit The location of the access hole for the Gas Disposal Vent depends on whether your system is a wall-mounted or post-mounted application. Refer to the illustrations in Figure 3 for correct vent hole placement. Complete the Gas Disposal Kit installation in accordance with the Installation Instructions [10420300] supplied with this kit; it is important that you heed all safety alerts stated in the Installation Instructions. Wall Mount 6 (15.2 cm) from stud (Refer to WARNING on Gas Disposal Kit Installation Instructions [10428300]) Existing Wall Studs Mounting Bracket 4 (1.2 m) to 5 (1.5m) from floor Vent Hole 6.62 (16.8 cm) from mounting bracket Make sure that the power cord reaches the outlet before mounting interface Post Mount Anywhere between studs (Refer to WARNING on Gas Disposal Kit Installation Instructions [10428200]) 12 (30 cm) to 18 (45 cm) from ceiling Vent Hole MX104100i Figure 3. Gas Disposal Vent Location 5

Section 3 INSTALLATION (cont.) 3.3 Installing the Scavenger Interface Note Check your location to make sure the tubing reaches from the anesthesia machine to the Interface and from the Interface to the Gas Disposal Vent (lengths vary based on interface mounting configuration [wall or post]). 3.3.1 WALL MOUNT Note Before mounting interface bracket to the wall, make sure the interface s power cord will reach the nearest grounded wall receptacle. Refer to Wall Mount illustration in Figure 3. Install the wall interface mounting bracket in accordance with the illustration in Figure 4. Once the mount has been successfully secured, the interface can be hung on to the hanger mounting tabs. Step 1: Position bracket on wall and mark hole locations. Step 4: Slide Interface onto mounting bracket tabs. Note: Make sure to locate wall stud and position bracket over stud. Note: Make sure tabs on both brackets are fully engaged. Step 3: Interface Insert washer and lag bolt through upper and lower center mounting holes. Note: Make sure tabs on the mounting bracket face upward. Lag Bolt Washer Step 2: Drill 5/32 (4mm) pilot holes into stud. Mounting Bracket MX104300i Figure 4. Wall Mounted Scavenger Interface Bracket Mounting 6

Section 3 INSTALLATION (cont.) 3.3 Installing the Scavenger Interface (cont.) 3.3.2 POST MOUNT Install the post interface mounting bracket in accordance with the illustration in Figure 5. Once the mount has been successfully secured, the interface can be hung on to the hanger mounting tabs. Step 4: Slide Interface onto mounting bracket tabs. Note: Make sure tabs on both brackets are fully engaged. Step 1: Position bracket onto post. Note: Make sure tabs face upward. Post Mounting Bracket U-bolt Step 3: Install washers and nuts and secure to post. Step 2: Slide U-bolts around post and through mounting holes in bracket. Washer MX104200i Figure 5. Post Mounted Scavenger Interface Bracket Mounting Nut *Total Tubing from Anesthesia Machine to Exterior Wall 3.4 Installing the Scavenger Tubing Can Not Exceed 100 Ft. Complete the tubing installation in accordance with the Tubing Kit Instructions (Post Mount [10428200] or (Wall Mount [10428300]) supplied with this kit. It is important that you heed any safety symbols and alerts stated in the Installation Instructions. Refer to Scavenging Hose Suspension Installation Instructions (10428100) for Preferred and Alternate tubing mounting methods. WARNING Do not install the tubing up through the roof or down along the floor. 7

Section 4 OPERATION 4.1 Operating your Anesthesia Gas Scavenging System (Active) Note This is an active scavenger system, do not use anesthesia machine unless scavenger interface is energized. Plug the Matrx by Midmark Scavenger Interface 12 volt power supply into a grounded receptacle. Turn the Scavenger on by activating the rocker switch, located on the upper side of the interface, to the ON position. A green light will illuminate when the interface is energized. Always energize the interface prior to activating your anesthesia machine and do not de-energize the interface until after you have turned your anesthesia machine off. ON ON OFF Green In Use Light OFF OFF Switch Position Figure 6. Interface ON/ OFF Switch ON Switch Position MX104400i Note The leak rate from the Matrx by Midmark Veterinary Anesthesia Gas Scavenging System (Active) is less than 100 ml/min during normal administration of anesthesia (excess gas flows of 10L/min or less). Test procedures are available upon request. 4.2 Tips for Optimal Scavenger Interface Performance Energize the Scavenger before you use it. To energize, switch the ON/OFF switch to ON. Do not clamp the 19mm tubing to the APL valve. Use your fingers to fasten the tubing to the APL valve by securing it over the fitting. Make sure all tube fittings are secure before turning the Scavenger on. Use only the tubing supplied with your Scavenger or Matrx by Midmark replacement tubing to avoid kinks or pressure in the tubing. Use the original tubing length or shorter. Never add additional tubing lengths to circuit. Make sure that the vent on the outside of the gas disposal assembly is clear and that air movement is not blocked or obstructed. Make sure that the vent on the outside of the gas disposal assembly is located away from people, doors, windows, and any air intakes or outlets. Make sure that the tubing is not lying on the floor. 8

Section 5 MAINTENANCE 5.1 General Cleaning and Replacement Inspect the Scavenger Interface and tubing circuit for damage before each use. If the unit appears to be damaged, do not use it; call your Matrx by Midmark Service Representative for replacement parts if necessary. 5.2 Periodic Maintenance Once A Week Once A Month Once A Years Clean the screen at the bottom of the Interface. Clean the Interface vents in the Interface Outlet Assembly; refer to Figure 8 for cleaning procedure. Check the Gas Disposal Vent outlet to make sure that it is not blocked by ice or other debris. Replace all 19mm tubing from APL valve to Interface. Replace all 32mm tubing from Interface to Gas Disposal Vent. Figure 7. Periodic Maintenance Chart ON OFF Equipment Alert In most cases the interface can be disassembled for this procedure while it remains mounted to a post or wall. Care should be taken in the event that it is removed from its mounting bracket as tubing damage could result. Interface Body Thumbscrews Step 1: Remove (3) thumbscrews from the lower portion of interface body and slide the interface outlet assembly out through the bottom of the interface. Note: Make sure to support the assembly during process. Step 3: Reinsert the interface outlet assembly into the interface body and install and secure the (3) thumbscrews. Step 2: Clean all lint and debris from unit especially around (7) vent screens. Vent Screens Interface Outlet Assembly MX104500i Figure 8. Cleaning Interface Vents 9

Section 5 MAINTENANCE (cont.) 5.3 Troubleshooting Guide The following troubleshooting guide is helpful in analyzing problems. For any service questions contact Matrx by Midmark Technical Support at 1-800-Midmark or your Matrx by Midmark dealer. SYMPTOM POSSIBLE REMEDIES No power to unit. Green In Use light does not go on when switch is in the ON position. Make sure unit is plugged in to the receptacle. Check receptacle for power. Make sure switch is in the ON position. Make sure unit is plugged in to the receptacle. Check receptacle for power. 19mm tubing does not fit snugly on APL If your anesthesia machine is not a Matrx by Midmark valve. Animal Anesthesia Machine, check the manufacturer s specifications to determine the diameter of their APL outlet fitting. If the fitting is not compatible, replace it with a Matrx by Midmark APL valve. Tubing is stretched or worn and should be replaced. 19mm tubing does not fit on Interface Make sure that you are fastening the tubing to the input port input port. on the bottom of the Interface. Tubing is stretched or worn and should be replaced. 32mm tubing does not fit on Interface Make sure that you are fastening the tubing to the outlet port outlet port. on the bottom of the Interface. Tubing is stretched or worn and should be replaced. Figure 9. Troubleshooting Chart 10

Section 5 MAINTENANCE (cont.) 5.4 Replacement Parts The following illustration shows all available replacement parts for this product. To order replacement parts or for any service questions, contact Matrx by Midmark Technical Support at 1-800-Midmark or your Matrx by Midmark dealer. 2 5 6 8 ON OFF 1 3 4 7 11 10 13 14 9 12 MX104700i Item Part No. Description Qty. Interface Kit Components 1a 94515143 Interface (domestic)... 1 1b 94515180 Interface (international)... 1 Gas Disposal Kit Components 2 91515140 Set Screw (#8-32 [not shown])... 1 3 91515141 Inner Wall Plate... 1 4 91515149 Tube Clamp... 1 5 91515150 Screen Stop (not shown)... 1 6 91515164 Screen (not shown)... 1 7 91515165 Worm Gear Clamp... 1 8 91515166 Gas Disposal Subassembly... 1 Figure 10. Replacement Parts Exploded View Item Part No. Description Qty. Post Mount Tubing Kit Components 9 91515168 Fastener Tube Kit...1 10 65939600 Transfer Tubing, Magenta (19mm)... 5 11 65939700 Disposal Tubing, Magenta (32mm) 20 Wall Mount Tubing Kit Components 12 91515168 Fastener Tube Kit...1 13 65939600 Transfer Tubing, Magenta (19mm). 18 14 65939700 Disposal Tubing, Magenta (32mm).. 2 11

Section 6 INFORMATION & WARRANTY 6.1 General Information & 6.2 Return Goods Procedure All repairs, unless otherwise specified, should be performed by an authorized Midmark service representative. Call 1-800-MIDMARK (1-800-643-6275) or Customer Service. 6.3 Warranty SCOPE OF WARRANTY Midmark Corporation ( Midmark ) warrants to the original retail purchaser that it will repair or replace components of the animal health products manufactured by Midmark (except for products and components not warranted under Exclusions ) that are defective in material or workmanship under normal use and service. The sole remedy under this limited warranty is the repair or replacement, at Midmark s option, of the applicable products or components. This limited warranty shall only apply to defects that: (i) are reported to Midmark within the applicable warranty period; and (ii) are determined to exist upon examination by Midmark. This limited warranty extends only to the original retail purchaser of a product, and is not transferable or assignable. APPLICABLE WARRANTY PERIOD Veterinary Anesthesia Gas Active Scavenger Interface: 1 year OBTAINING WARRANTY SERVICE Warranty service must be obtained through either Midmark or an authorized dealer in the Midmark product line for which warranty service is requested. Midmark may be contacted for warranty service inquiries or issues via email at www.midmark.com, by mail to Midmark Corporation, 60 Vista Drive, Versailles, Ohio 45380, or by phone at: 1-800-MIDMARK. It is the retail purchaser s obligation to arrange for delivery of a product to Midmark or one of its authorized dealers for warranty service, which delivery shall be at retail purchaser s expense. It is also the retail purchaser s obligation to comply with the warranty service instructions provided either by Midmark or its authorized dealer. The retail purchaser must provide Midmark with completed warranty registration information within thirty (30) days after purchase in order to obtain the benefits of this limited warranty. EXCLUSIONS This limited warranty does not cover and Midmark shall not be liable for the following: (1) defects, damage or other conditions caused, in whole or in part, by misuse, abuse, negligence, alteration, accident (including animal acts of any kind), freight damage, tampering or failure to seek and obtain repair or replacement in a timely manner; (2) matching of color, grain or texture except to commercially acceptable standards; (3) changes in color caused by natural or artificial light; (4) products which are not installed, used and properly cleaned and maintained as required in the installation and operation manuals for the applicable product (imaging product must be installed by a certified Midmark installer); (5) products considered to be of a consumable nature; (6) accessories or parts not manufactured by Midmark; (7) specially manufactured products; (8) charges by anyone (including Midmark s authorized dealers) for adjustments, repairs, replacement parts, installation or other work performed upon or in connection with such products which are not expressly authorized in writing in advance by Midmark; (9) costs and expenses of routine maintenance and cleaning; (10) all sinks, faucets and plumbing accessories; (11) representations and warranties made by any person or entity other than Midmark; and (12) with respect to software that is a product or a component thereof, that the software will be error free, can be used without problems or interruptions, or will be free from vulnerability to intrusion or attack by viruses or other methods. EXCLUSIVE REMEDY; CONSEQUENTIAL DAMAGES DISCLAIMER Midmark s only obligation under this limited warranty is the repair or replacement of defective parts. Midmark shall not be liable for and hereby disclaims any direct, special, indirect, incidental, exemplary or consequential damages or delays including, but not limited to, damages for loss of profits or income, loss of use, downtime, cover, and employee or independent contractor wages, payments and benefits. This disclaimer shall survive any failure or asserted failure of the essential purpose of this limited warranty or its remedies specified herein. NO AUTHORIZATION No person or firm is authorized to create or approve for Midmark any other obligation or liability in connection with Midmark products. WARRANTY DISCLAIMER: THIS LIMITED WARRANTY IS MIDMARK S ONLY WARRANTY AND IS IN LIEU OF ALL OTHER WARRANTIES, EXPRESS OR IMPLIED. MIDMARK MAKES NO IMPLIED WARRANTIES OF ANY KIND INCLUDING ANY IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. STATUTE OF LIMITATIONS No action may be brought against Midmark for breach of this limited warranty, an implied warranty, if any, or for any other claim arising out of or relating to the products, more than ninety (90) days following expiration of the warranty period. In the event multiple warranty periods exist with respect to a product, the ninety (90) day period provided for herein shall begin to run from expiration of the warranty period for the component to which the claim relates. SEVERABILITY In the event any provision of this limited warranty is determined to be invalid or otherwise unenforceable: (i) the provision shall be enforced in a manner that closest holds to its intent, while at the same time curing the invalidity or unenforceability, and (ii) the balance of this limited warranty, being severable, shall not be affected in the event the provision that is invalid or unenforceable cannot be enforced in any respect. 12

Notes and Contact Information Unit Serial Number Date Purchased Dealer Name Dealer Phone Number Notes: Contact Information: 1-800-Midmark (643-6275) www.midmark.com iv