Eclipse Plus VA UPS and Surge Suppressor User s Manual

Similar documents
Uninterruptible Power Supply

BRAVER UPS. (Uninterruptible Power System) User s Manual

USER MANUAL. Blazer Vista 1000/1400/2000. Uninterruptible Power System

UPS USER MANUAL F-11 LINE INTERACTIVE UPS GENERAL PURPOSE UPS 650VA/1200VA/2200VA

800VA/ 1000VA/ 1200VA/ 1500VA 2200VA/ 3000VA USER S MANUAL

Limousin II User Manual

Uninterruptible Power System

Pulsar Evolution 2200/3000/3000 XL

Powerware Vdc Extended Battery Cabinet User s Guide.

USER MANUAL. Uninterruptible power supply MODEL: 53965,

MM-AVR UPS Series User s Manual

USER MANUAL. PowerMust 1400/2000 LCD. Uninterruptible Power System

USER S MANUAL CONTENTS. Uninterruptible Power Supply 1. INTRODUCTION SAFTY INSTRUCTION SYSTEM DESCRIPTION... 4

CP900EPFCLCD User s Manual K

POWERWARE User s Guide VA.

Liebert PSA VA. Installer/User Guide

User Manual. NetGuard IMPORTANT. PSD 650/1200/1600 Line Interactive UPS Uninterruptible Power Supply System. UPS Monitoring Software

Uninterruptible Power System

PR1000ELCD / PR1500ELCD User s Manual

Back-UPS 650 VA 230 V with AVR (BX650CI-ZA)

Uninterruptible Power Supply USER MANUAL Version 1.4. Always On UPS Systems Inc. GES-801L, GES-102L, GES-152L, GES-202L, GES-302L

1. INTRODUCTION SYSTEM DESCRIPTION Front Panel CONNECTION AND OPERATION TROUBLESHOOTING...8

Back-UPS ES APC Back-UPS ES, 6 outlet 350VA, 120V, without auto shutdown software

Pulsar Evolution 1500 / 1500 Rack 1100 / 1100 Rack 800 / 800 Rack 500 Rack

User Manual Easy UPS BV Series 500VA, 650VA, 800VA, 1000VA Safety and General Information

02/15/01. Powerware User s Guide VA.

USER S MANUAL CONTENTS. Uninterruptible Power Supply 1. INTRODUCTION SAFTY INSTRUCTION CABLE CONNECTION... 4

User Manual Back-UPS BX650CI-MS 230 Vac with AVR

Installation and Operation Manual Back-UPS BR800/1100CI-IN

Back-UPS CS Back-UPS CS 350

User Manual Digital Energy Uninterruptible Power Supply ML Series UPS VA GE Digital Energy Power Quality

USER MANUAL ONLINE UPS 6000L(XL)/10000L(XL) Uninterruptible Power Supply

USER MANUAL. Uninterruptible Power Supply Line-interactive VCL Series UPS VA

Pulsar EXtreme 2200C / 3200C

User Manual Back-UPS BC500-RS, BC650-RS 650 VA 230 V

Uninterruptible Power System

User Manual. Digital Energy Uninterruptible Power Supply ML Series UPS VA. GE Digital Energy Power Quality. GE imagination at work

Installation Guide Smart-UPS On-Line SRT1000/SRT1500 XLA Tower/Rack-Mount

Installation and Operation Back-UPS BX550CI-CN

USER MANUAL. Power GUARD UPS. Uninterruptible Power System

Users Manual. Defender 1 8.0KW to 14.0KW Online Emergency Lighting Inverter. Technical Manual # Revision B

Pulsar EXtreme CLA 1500C

Users Manual. Cobra Plus Stand-By Emergency Lighting Inverter. Technical Manual # Revision B

3000VA 120/208/230VAC

POWER TROLLEY 8 INSTRUCTION MANUAL POWER TROLLEY 8. Model: SINE Instruction Manual for: Self-Contained Sinewave Mobile Power Backup System

Installation and user manual 5SC 500 5SC 750 5SC SC SC 500G 5SC 750G 5SC 1500G ENGLISH. Copyright 2013 EATON All rights reserved.

400 Watt Backup Power System Owner s Manual

User Manual V1.1 OptiFlex 1100 / OptiFlex 2000

Thank you for choosing EATON products. Safety information and operating instructions are included in this manual. Do not attempt to operate the UPS

Uninterruptible Power System. Line Interactive Network Protection Pure Sine Wave Output UPS. Rack Mount Models 1000VA/ 1500VA/ 2000VA/ 3000VA

CONTENTS 1. INTRODUCTION SAFTY INSTRUCTION CABLE CONNECTION SYSTEM DESCRIPTION INVERTER OPERATION...

LIFT 1500 VA UNINTERRUPTIBLE POWER SUPPLY UPS USER MANUAL

User s Manual Legend SB825 UPS K

1. INTRODUCTION. Features:

WF-5110R True Sine Wave Inverter

Sola 3000 Guide Specifications

User s Manual Lineage LI3000 UPS K

USER MANUAL English / Español

SOS SERIES SOS1 SOS2. Spares On Site Battery Cabinet Installation Guide rEV3

Installation and Operation Manual Back-UPS BX1100CI-CN

Allen-Bradley. User Manual for 8000/10000 VA UPS. Tower/Rack-Mount 6U Uninterruptible Power Supply

XPC-EBP64 External Battery Pack User & Installation Manual Xtreme Power Conversion Corporation. All rights reserved.

On Line UPS. LUC 1000E / LUC 2000E / LUC 3000E User Manual

3. MAJOR SYSTEM COMPONENTS Emergency Lighting Power System shall consist of the following major subsystems:

Sola/Hevi-Duty S3K Series Mini-Tower UPS

Evolution 650/650 Rack 1U 850/850 Rack 1U 1150/1150 Rack 1U 1550/1550 Rack 1U Installation and user manual FR/AA - Page 1

WF-5110R True Sine Wave Inverter

UTILITY INPUT MAINS OUTLET

Match 19" GE Digital Energy. Uninterruptible Power Supply VA. Technology for the Digital World. Match 19" UPS.

Allen-Bradley. User Manual for 3000/5000 VA UPS. Tower/Rack-Mount 3U Uninterruptible Power Supply

Line Interactive UPS 1000/1400/2000VA Uninterruptible Power System

User Manual Rittal PMC UPS 6kVA

Informer Compact Series

Power Inverter. User s Manual. Diamond Series CPD1200EILCD

Uninterruptible Power System

CONTENTS 1. INTRODUCTION SAFTY INSTRUCTION CABLE CONNECTION SYSTEM DESCRIPTION OPERATION... 9

TECHNICAL SPECIFICATION FOR A 10 TO 50 KVA THREE PHASE, UNINTERRUPTIBLE POWER SYSTEM WaveRider III

User Manual V1.0 MaxiFlex 3000

CERTIFIED CATEGORY III-3 PROTECTION

USER MANUAL MPS 1-5KW SERIES

User Manual. PF0.9 1K/2K/3K Online UPS. Uninterruptible Power Supply System. Version: 1.3

WF-5100 Series True Sine Wave Inverters

Solar Hybrid Power Generating System CPS1200EOH12SC CPS2200EOH24SC CPS3000EOH24SC. User s Manual K01-C

NB NB 1511 NB NB 4031 TRUE ON-LINE DOUBLE CONVERSION UPS

General Precautions. Personnel Precautions

User Manual. English. APC Smart-UPS. 750/1000/1500 VA 100/120/230 Vac 2U Rack-Mount Uninterruptible Power Supply

Liebert PowerSure PSI UPS

Installation and Operation Manual Back-UPS BX800CI-ZA/BX1100CI-ZA

Installation and Operation Manual Back-UPS BR1000-CH

Aurora Single Phase Emergency Lighting Inverters

USER MANUAL DN / DN

3 Uninterruptible Power Systems

USER MANUAL ONLINE UPS

INSTALLATION & OPERATION MANUAL

O W N E R ' S M A N U A L

Model ESV Uninterruptible Power System 1.5 KVA/KW KVA/KW Single Phase

U n i n t e r r u p t i b l e P o w e r S y s t e m

Liebert GXT MT+ User Manual VA Installer/User Guide

Home Solar 400 (HS 400) Home Solar 800 (HS 800) Home Backup 400 (HB 400) Home Backup 800 (HB 800) Owner s Manual

Transcription:

Eclipse Plus 250 250VA UPS and Surge Suppressor User s Manual Compact UPS/Surge Suppressor for Home Office or Small Office Use www.mgeups.com

Notes Contents Thank You!..................................................... 2 MGE UPS Systems.............................................. 2 Why the Need for Uninterruptible Power?.............................. 2 Theory of Operation.............................................. 2 Instructions for Operation....................................... 3 & 4 LED Operation Table..............................................3 Getting Maximum Battery Life From the Pulsar Eclipse Plus 250.............4 Sizing Guide....................................................5 Product Specifications.............................................5 Troubleshooting..................................................5 Maintenance....................................................6 Service and Parts................................................6 UPS Recycling..................................................6 US and Canada Domestic Warranty...................................6 Maintenance Log.................................................6 2 normal UPS/surge protected outlets, 1 spaced outlet for transformer block (UPS side) User-replaceable battery access door on unit bottom 2 surge only protected outlets, 1 spaced outlet for transformer block (surge suppressor side) 6 foot input cord Output circuit breaker Unit can be wall-mounted with screws (not included) Red fault Indicator ID labels for protected device identification (not shown) Cable organizers for neat cable routing (not shown) Figure 1 Fax/modem protector Contact closures for special applications (DB9, Communication Port) On/Off Switch Green on utility/on battery indicator page 8 86-153538-00 MGE UPS Systems MGE UPS Systems Eclipse Plus 250 User s Manual page 1

Maintenance Clean the UPS with a dry cloth after turning off all power to the UPS and switching off the power switch. The UPS performs weekly automatic battery tests. However, it is recommended that 6 month tests be performed on the UPS for battery condition. Perform all tests off peak hours with applications shut down. 1. Turn off power to the UPS via the circuit breaker to the UPS. It is not recommended to disconnect the plug from the UPS to the utility power due to disconnection of the safety ground. 2. Allow UPS to run on battery power for 1 minute. Monitor the UPS for any fault LEDs and if none are observed, return power to UPS and log results below in the maintenance log. Service and Parts In USA or Canada, call 1-714-557-1636 x 578. State your name, request, and phone number. Your call will be returned the next business day. You may also visit our web site at: www.mgeups.com UPS Recycling In USA or Canada, call 1-714-557-1636 x 578. Ask for a return goods authorization for free UPS or battery recycling. MGE does not cover return freight charges for recycling and will not accept items without a return goods authorization number. US and Canada Domestic Warranty 2 years parts and labor for the original owner. One way shipping charges are provided by MGE by surface freight. Proof of purchase may be requested by MGE before any service can be performed. Refer to separate circular for $10K connected equipment warranty. Maintenance Log UPS serial number Date of installation Location Notes Date Check Comments 6th month 12th month 18th month 24th month 30th month 36th month 42nd month 48th month 54th month 60th month Instructions for Operation CAUTION: Always turn off all power to computer prior to making any Pulsar Eclipse Plus 250 connections. See Figure 1 (on page 1) and Figure 2 (on this page) for connection details. 1. Unpack UPS and accessories from shipping carton. 2. Connect input cord into a properly sized AC outlet. Allow eight hours for batteries to recharge. IN OUT ON/OFF FAX/MODEM PROTECTOR Figure 2 3. Connect critical devices (computer, monitor, modem) on battery backed up outlets keeping load within the maximum of 250 VA. The battery backed up outlets are identified by a computer icon (do not plug laser printers or surge strips into this side of the UPS). 4. Peripherals are plugged into surge filtered outlets that are identified by a printer icon. 5. Connect fax/modem cable if utilized ( RJ11 cord is provided for fax/modem protector only). See Figure 2 at left. 6. Switch on and allow UPS to recharge 8 hours for full battery capacity. Communication Port (DB9, see Figure 1, page 1) Ratings are limited to 16ma @ +12 VDC with respect to Pin 5 (common). Pin 3: UPS shutdown control, >5 VDC for 5 seconds, 5 ma Pin 4: On battery contact, opens Pin 5: Common 5 4 3 2 1 Pin 7: Low battery contact, closes Pin 9: On battery contact, closes 9 8 7 6 Eclipse Plus 250 Red LED Green LED Figure 3 LED Operation Table (see Figure 3) LED Status Comment Green LED lit continuous UPS on and Normal operation utility power is available Green LED flashes once UPS on battery power Utility power has failed every 4 seconds and audible alarm beeps once every 4 seconds Green LED flashes once UPS on battery power Battery near exhaustion every second and audible alarm beeps once every second Red LED flashes 3 times Faulty battery Replace battery every 2 seconds and (see "Battery Replacement" audible alarm beeps 3 times below) every 2 seconds Red LED flashes twice every Overload Reduce load, restart UPS second and audible alarm beeps twice every second Red LED lit continuous and Internal failure Reduce load, restart UPS, if red continuous audible alarm or overload shutdown LED reappears, call for assistance Notes: 1. Always leave UPS on. Do not use UPS as master switch. You do not have to switch on the UPS for the batteries to remain charged. 2. If the utility power failure exceeds the battery back-up time, Pulsar Eclipse Plus 250 shuts off to prevent excessive battery discharge and will re-start up as soon as power returns. 3. The overload protection breaker (Figure 1) trips off during a severe overload. If this occurs, unplug excess loads and reset circuit breaker by pressing its reset button. page 6 86-153538-00 MGE UPS Systems MGE UPS Systems Eclipse Plus 250 User s Manual page 3

Instructions for Operation Getting Maximum Battery Life From the Pulsar Eclipse Plus 250 1. Prior to first use, charge the Pulsar Eclipse Plus 250 battery for 8 hours. This helps condition the battery for long life. 2. After a complete discharge, a few hours are required to reach full recharge. Notes: 1. Pulsar Eclipse Plus 250 is equipped with a 12V/4.2Ah lead acid battery, which must be disposed of in accordance with local regulations. MGE will accept UPS and/or batteries for recycling free of charge. Contact us at the phone number shown in the recycling section of this manual. 2. Battery life is cut in half for every 15 degrees above 75 F. Plug in and recharge the UPS at least every six months if the UPS is taken out of service and not plugged in. ID Labels and Cable Organizers Eclipse Plus 250 includes ID labels to label each item plugged into the UPS. Simply peel off the label which matches the device you have plugged in (or type the name on the blank labels) and attach it to the recess next to the outlets. Attach the matching label to the cord of the device. In this way, you can always return each device to its proper location should you need to remove it. The cable organizers are provided to clean up" the installation. Locate the cable organizer where it will restrain the cables to the UPS in optimum locations. Clean the location where the organizer will be mounted to remove any traces of oil or dirt. Remove the covering on the self-adhesive backing. Press into position and allow to set overnight for adhesion to properly set. Be sure to attach organizer when temperatures are above 70 F. Press cables into organizer and close cover. Battery Replacement Battery door Battery access screw Figure 4 Caution: read and follow safety instructions before removing batteries. This must be done by knowledgeable personnel due to risk of electric shock and high energy. 1. In accordance with local regulations and proper disposal of Pulsar Eclipse Plus 250 battery(s), it is necessary to remove them from UPS chassis for recycling and replacement. 2. Turn off and unplug UPS and all critical devices. 3. Open the door located on the bottom of the UPS. A torx T15 screwdriver is required for this procedure. 4. Remove screw and follow operations described in Figure 4 to open the door and slide out the battery. 5. Unplug the battery for replacement. Replace with only exact matching battery available from MGE. 6. Insert new battery and reconnect. 7. Close door and reinstall screw. 8. Plug in UPS to utility power and all critical devices. Restart. in out Fax/Modem protector Sizing Guide "Computer Outlets" Monitor Back up Time 486, Pentium, Celeron, 14, 15" monitor 10 minutes Pentium Pro, K6 imac 14, 15 " monitor 8 minutes 486, Celeron, Pentium, 16, 17" monitor 7 minutes Pentium Pro, K6 Pentium II, Pentium III 14, 15" monitor 5 minutes Pentium II, Pentium III 17" monitor 3 minutes Back up Time Load Back up Time 50 VA 30 minutes 100 VA 21 minutes 150 VA 10 minutes 200 VA 7 minutes 250 VA 5 minutes Product Specifications UPS rating: 250 VA/168 W (2.1 A) Battery: 1 system, 12 volt/4.2 Ah Surge suppressor rating: 950 VA (8 A) Battery life: 5 years with normal use Input voltage: 120 VAC, 50/60 Hz Operating temperature: 32 104 F up to 1500M Output voltage: 120 VAC 50/60 Hz Storage temperature: -5 122 F UPS back-up time: 5-30 minutes Size: 10" L X 7" W X 2.6" H UPS output wave shape: Modified sine Weight: 6.6 lbs. Surge suppressor joule rating: 450 Warranty: 2 years parts and labor Input cord: 6 foot with NEMA 5-15 plug Accessories: ID labels, cable organizers, Circuit breaker: 10 amp fax/modem cable UPS (on battery) current limit: >250 VA Agency: UL, cul, FCC Recharge time: 8 hours Troubleshooting UPS has no output and no LED display UPS has little or no back-up time UPS transfers to battery, flashes green and audible alarm beeps often LED lights red, continuous audible alarm LED flashes red twice a second with beep twice a second Check to be sure UPS is plugged in, AC power is "on" to UPS and UPS is turned "on". Charge UPS overnight and retry. After 3-5 years, consider replacing batteries if back-up time is short. Many low voltage events or poor voltage regulation at receptacle. Try another receptacle. Potential internal failure. Restart UPS, if red LED reappears. Call for assistance. UPS lightly or heavily overloaded. Reset circuit breaker on UPS if necessary. Reduce load and restart UPS. MGE maintains a phone number for technical support for US and Canadian customers. Call for assistance as shown in the "Service and Parts" section of this manual or visit our web site at: www.mgeups.com page 4 86-153538-00 MGE UPS Systems MGE UPS Systems Eclipse Plus 250 User s Manual page 5

Thank You! Thank you for your purchase of the Eclipse Plus 250 "UPS" from MGE. The Eclipse Plus 250 "UPS" will provide many years of accurate, trouble-free power protection for your PC and/or other device(s). Please read this manual fully, to familiarize yourself with the safety and many other features of the Eclipse Plus 250 product. MGE UPS Systems MGE, one of the largest UPS manufacturers in the world, has a power protection solution for every power problem. Our product range includes UPSs 220 VA to over 4.5 MVA in single and three phase configurations. Other products include Power Management Software, DC to AC inverters, line conditioners and isolation transformers. Contact your sales representative today for additional information about MGE s other fine products. Our web address is: www.mgeups.com Why the Need for Uninterruptible Power? PCs and other electronic devices, due to their design, are subject to the effects of power outages or short interruptions. They do not store sufficient energy to overcome outages or short interruptions and these events occur on a daily basis. Any interruption of the utility power will stop the operation of a computer and cause loss of data, potential hardware damage and inconvenience. A "UPS" is an uninterruptible power supply. The UPS has an internal battery to provide power back-up when the utility power is lost or a short outage occurs. In addition, the Eclipse Plus 250 UPS provides surge protection from indirect lightning strikes, power surges and short high voltage transients (spikes) created by machinery or common office equipment. A fax/modem suppressor with cable is provided with every MGE Eclipse Plus 250 UPS to also protect the incoming data line to the PC. Theory of Operation Eclipse Plus 250 is an off-line or stand-by UPS which normally operates in the bypass mode. Surge suppression and filtering are also provided in this mode. The UPS transfers the load quickly to the battery when a power failure occurs. If the power returns before the battery is exhausted, the operation returns to normal and the battery is recharged. The Eclipse Plus 250 UPS is comprised of three major systems: the inverter, the battery charger/ battery and the bypass. All logic and supervision in the UPS are provided by a state-of-the-art microcontroller. Inverter The inverter is the heart of the UPS and inverts direct current (DC) from the battery into alternating current (AC) at 120 volts. The DC voltage from the batteries (12 volts DC) is switched on and off at a high frequency and transformed to a higher voltage (DC to DC conversion). After conversion, the high voltage is converted into a pseudo-sine wave by a pulse width modulated (PWM) inverter to 120 volts AC RMS. This unique MGE technique, eliminates all bulky 60 HZ components and reduces size, heat, and greatly enhances reliability. Battery Charger/battery The battery charger maintains the battery and the battery provides the source of backup energy when a power failure occurs. The battery charger converts 120 volt AC utility power to filtered and regulated DC specific for battery charging. The battery is a recombinant, sealed, lead acid-type which provides the high current required for UPS use and long life. It requires no additions of water during its life. Bypass The bypass is the electro-mechanical hardware providing a transfer to or from the inverter. This is done rapidly and synchronized to the utility power sine wave in order to provide continuity to the PC and not cause a re-boot. Notes page 2 86-153538-00 MGE UPS Systems MGE UPS Systems Eclipse Plus 250 User s Manual page 7

Save These Important Safety Instructions This manual contains important instructions for Pulsar Eclipse Plus 250 that should be followed during installation and maintenance of the UPS and batteries. This equipment can be operated by an individual, with no previous training. All repairs should be performed by qualified service personnel. The UPS contains voltages which are potentially hazardous. CAUTION: Risk of electrical shock, even with unit disconnected from AC power source. Hazardous voltage still may be present through operation from battery. The battery supply should be disconnected at the plus (+) and minus (-) terminals using the fast-on connectors of the battery when maintenance or service work inside the UPS is necessary. Do not place Pulsar Eclipse Plus 250 near water or in environment of excessive humidity. Do not allow liquids or any foreign objects to get inside Pulsar Eclipse Plus 250. Do not plug household appliances such as hair dryers to Pulsar Eclipse Plus 250 receptacles. Do not place Pulsar Eclipse Plus 250 under direct sunlight or close to heat-emitting source. The AC power receptacle shall be near the equipment and easily accessible. To isolate Pulsar Eclipse Plus 250 from AC input, remove the input power cord from the AC power receptacle. If Pulsar Eclipse Plus 250 is to be stored for a long time, it is recommended to recharge the batteries (by connecting AC power source to Pulsar Eclipse Plus 250, switch "ON" or OFF"), once a month for 8 hours to avoid a full battery discharge. Pulsar Eclipse Plus 250 contains batteries that should be disposed of or recycled in accordance with local laws. Prior to installation, store Pulsar Eclipse Plus 250 in a dry location. Ambient temperature for operation 32 F (0 C) and 104 F (40 C). Storage temperatures must be between -5 F (-15 C) and 122 F (50 C). Servicing of batteries should be performed or supervised by personnel knowledgeable of batteries and the required precautions. Keep unauthorized personnel away from batteries. When replacing the batteries, use MGE part number 112-00065-00 batteries (12V- 4.2Ah lead acid), use of any other battery may present a risk of fire or explosion. ~ : Alternating current supply symbol. CAUTION: Do not dispose of battery or batteries in a fire. The battery may explode. Do not open or willfully damage the battery or batteries, since the released electrolyte is harmful to the skin and eyes. It may be toxic. A battery can present a risk of electric shock and high short circuit current. The following precautions should be observed when working with batteries for disposal or replacement: Switch off the UPS (on/off switch) and disconnect it from utility power; remove watches, rings or other metal objects, use tools with insulated handles, wear rubber gloves, boots and safety glasses. Federal Communication Commission (FCC) Statement Note: This equipment has been tested and found to comply with Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when equipment is operated in a residential environment. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Properly shielded and grounded cables and connectors must be used in order to meet FCC emission limits. Notes SP -ECL250-Rev C00 8/99 ECN - 000367 86-153538-00 MGE UPS Systems MGE UPS Systems Eclipse Plus 250 User s Manual page 9