Wind Turbine Generator System Safety and Function Test Report. Atlantic Orient 15/50 Wind Turbine

Similar documents
Wind Turbine Generator System Safety and Function Test Report. Bergey Excel-S with Gridtek-10 inverter

Wind Turbine Generator System. General Specification for HQ2000

Sacramento Municipal Utility District s EV Innovators Pilot

Technical Documentation Wind Turbine Generator Systems /60 Hz

Renewable Energy Systems

MASTER \ C. Idaho National Engineering Laboratory. INEL 96J014t we.l~%/0o/60 PREPRINT. MOTOR-OPERATOR GEARBOX EFFICIENCY 5 i u.

Model: H kW. Features: 1. SCF Supercritical generator. 2. NSK bearings. 3. PLC integrated with Siemens module. 4. Low noise

Hybrid Electric Vehicle End-of-Life Testing On Honda Insights, Honda Gen I Civics and Toyota Gen I Priuses

The Realities of Consumer-Owned Wind Power For Rural Electric Co-operatives

Product Presentation. September 09

Model-Based Integrated High Penetration Renewables Planning and Control Analysis

REFERENCE MANUAL FORM: MX-TRM-E REL REV MTE

Technical specifications. Wind Turbine GS 21 S. Power 60 kwp

DEEP SEA ELECTRONICS PLC

Adelaide Wind Power Project Turbine T05 (AD117) IEC Edition 3.0 Measurement Report

REPORT ON TOYOTA/PRIUS MOTOR DESIGN AND MANUFACTURING ASSESSMENT

Test Summary Report for the Solid Wind Power SWP25-14TG20 Small Wind Turbine

APPENDIX J V90 3.0MW Turbine Specifications

T701 (240 VAC, 1-phase, 60 Hz)

Matrix APAX. 380V-415V 50Hz TECHNICAL REFERENCE MANUAL

GENERAL SPECIFICATIONS

TANK RISER SUSPENSION SYSTEM CONCEPTUAL DESIGN (U)

JOINT VENTURE: Wind Power Development Project United States of America. - Proposal Appendix -

Wind Turbine Testing

EE 742 Chap. 7: Wind Power Generation. Y. Baghzouz Fall 2011

NIAGARA REGION WIND FARM PROJECT DESCRIPTION REPORT. Appendix C. Turbine Specifications

BLOCKING DIODES AND FUSES IN LOW-VOLTAGE PV SYSTEMS

INSTRUCTIONS FOR THE RELIANCE CONTROLS ARM SERIES AUTOMATIC TRANSFER SWITCH

Determination of Spring Modulus for Several Types of Elastomeric Materials (O-rings) and Establishment of an Open Database For Seals*

Hedeager Aarhus N Denmark

Hedeager Aarhus N Denmark

THE ALTERNATIVE FUEL PRICE REPORT

INTERCONNECTION STANDARDS FOR PARALLEL OPERATION OF SMALL-SIZE GENERATING FACILITIES KILOWATTS IN THE STATE OF NEW JERSEY

Alternative Fuel Price Report

Hedeager Aarhus N Denmark. Vestas V110-2 MW 50 Hz VCS Mk 10

Exercise 4-1. Nacelle Control System EXERCISE OBJECTIVE DISCUSSION OUTLINE DISCUSSION. Control and simulation of environmental conditions

Excel 10 (240 VAC, 1-phase, 60 Hz)

V MW An efficient way to more power

LA10 (480 VAC, 3-phase, 60 Hz)

V MW The future for low wind sites

Utilization of Associated Gas to Power Drilling Rigs A Demonstration in the Bakken

Electron Positron Proton Spectrometer for use at Laboratory for Laser Energetics

Definitions. Scope. Customer Generation Interconnection Requirements

EVALUATING VOLTAGE REGULATION COMPLIANCE OF MIL-PRF-GCS600A(ARMY) FOR VEHICLE ON-BOARD GENERATORS AND ASSESSING OVERALL VEHICLE BUS COMPLIANCE

TECHNICAL SPECIFICATION FOR INDEPENDENT POWER PRODUCERS. NB Power Customer Service and Distribution. June 2008

MODERN GRID S T R A T E G Y

SHORT-STOP. Electronic Motor Brake Type G. Instructions and Setup Manual

GOLDWIND S48/ kW Industrial Wind Turbine (50Hz) World Wide Shipping. Immediate Availability. Installation Services.

DEEP SEA ELECTRONICS PLC

Intertek Test Report No CRT-005a Project No. G

MODEL 422 Submersible Pump Controller

MODEL 520 REMOTE START ENGINE MANAGEMENT SYSTEM

Glendale Water & Power Smart Grid Project

Pioneer P750/49. The Premium 750 KW Wind Turbine. green. pioneer. go go with

Avda. Ciudad de la Innovación Sarriguren (Navarra) Spain

SeaGen-S 2MW. Proven and commercially viable tidal energy generation

Session 8: Distributed Energy Resources Utility Concerns, Grid Impacts and Mitigation Strategies October 21, 2015 Santiago, Chile

ENERCON GmbH Dreekamp Aurich Germany ENERCON E-82 E4 2.35MW ENERCON E-82 E4 3.0MW. IIA, IEC : Amd1:2010

Avda. Ciudad de la Innovación Sarriguren (Navarra) Spain

GOLDWIND S48/750 (50Hz) Technical Specifications

A Study of Lead-Acid Battery Efficiency Near Top-of-Charge and the Impact on PV System Design

Test Rig Design for Large Supercritical CO 2 Turbine Seals

Hedeager Aarhus N Denmark. Vestas V MW / V MW

Hedeager Aarhus N Denmark

B-03 ELECTRICIAN TRAINING SKILL DEVELOPMENT GUIDE

Reliability Driven By Technology. M a k e t h e r i g h t m o v e...

Ref: NIWE/OSWH&IB/EMPL/ Date: Sub: Modified Procedure for empanelment of small wind turbines with MNRE / NIWE Reg.

M T E C o r p o r a t i o n MATRIX FILTER. SERIES B Volts, 50HZ USER MANUAL PART NO. INSTR REL MTE Corporation

4lliedSig nal. Development of a Digital Control Unit to Displace Diesel Fuel With Natural Gas. Federal Manufacturing & Tech nolog ies. A. D.

Document Requirements for Engineering Review- PV Systems v1.1 12/6/2018

CDBR-B. Instruction Manual. Dynamic Braking Unit. March 2013 Part Number: R4 Copyright 2013 Magnetek

DESCRIPTION OF AEROGENERATOR

Louisville Gas and Electric Company

DOUBLE ROW LOOP-COILCONFIGURATION FOR HIGH-SPEED ELECTRODYNAMIC MAGLEV SUSPENSION, GUIDANCE, PROPULSION AND GUIDEWAY DIRECTIONAL SWITCHING

SolarMill SM1-1P, SM1-2P, SM2-3P, SM2-5P, SM2-6P. User manual. Draft. SM1 - Product shown may vary slightly from specific model shipped

Hedeager Aarhus N Denmark S (IEC IB)*, :2005

Jerry Shoemaker Manager, Smart Grid PMO February 20, 2014

THE IMPACT OF BIODIESEL FUEL BLENDS ON AFTERTREATMENT DEVICE PERFORMANCE IN LIGHT-DUTY VEHICLES

Guide for Primary Injection Testing WL Circuit Breakers. Document No. : 11-C

V MW & 2.0 MW Built on experience


Photographs of large cities, such as Seattle, Washington, are visible reminders of how much people rely on electrical energy.

FD21-50 GHREPOWER. Version: 3.0

M T E C o r p o r a t i o n MATRIX FILTER. SERIES B Volts, 50HZ USER MANUAL PART NO. INSTR REL MTE Corporation

V MW Creating more from less

SWCC Summary Report. Eveready Diversified Products (Pty) Ltd T/A Kestrel Renewable Energy. Certification Number: SWCC (240 VAC, 1-phase, 60 Hz)

Continuing Education Course #206 Introduction to Designing Machine Control Systems Part 2

New dimensions. Siemens Wind Turbine SWT Answers for energy.

Types of Motor Starters There are several types of motor starters. However, the two most basic types of these electrical devices are:

EE 742 Chap. 7: Wind Power Generation. Y. Baghzouz

Summary of General Technical Requirements for the Interconnection of Distributed Generation (DG) to PG&E s Distribution System

ENERCON GmbH ENERCON E-66. page 1 of 6. Design. Dreekamp 5 Tel.: / Aurich Fax: / Design

Ex. 1-1 Nacelle Familiarization and Safety Discussion

ned100 Wind Turbine Generator a step towards your energy independence

Drive System Application

INSTRUCTIONS FOR THE RELIANCE Fast/Tran TM ARL0909 & ARL0909R

AeroVironment Universal Solar Pump Controllers

One Earth Opp. Magarpatta City Pune, India. Suzlon S120 DFIG 2.1MW (50 Hz)

Hedeager Aarhus N Denmark

Reliable and Application specific. Slewing Drives for Wind Turbines

Transcription:

June 23 NREL/EL-5-34382 Wind Turbine Generator System Safety and Function Test Report for the Atlantic Orient 15/5 Wind Turbine by National Wind Technology Center National Renewable Energy Laboratory 1617 Cole Boulevard Golden, Colorado 841 12 June 23 Wind Turbine Generator System Safety and Function Test Report for the Atlantic Orient 15/5 Wind T Page 1 of 19

1. Table of Contents 1. TABLE OF CONTENTS...2 2. TABLE OF FIGURES... 2 3. TABLE OF TABLES... 2 4. DISCLAIMER... 3 5. TEST OBJECTIVE... 3 6. BACKGROUND... 3 7. TEST TURBINE... 4 8. TEST SITE... 7 9. INSTRUMENTATION AND TESTING PROCEDURE... 8 9.1. Instrumentation... 8 9.2. Test Procedures... 8 1. RESULTS... 1 11. REFERENCES... 14 APPENDIX A: OVERSPEED TEST...A-1 2. Table of Figures Figure 1. Overall configuration of the AOC 15/5 test turbine...5 Figure 2. Tower-top configuration of the AOC 15/5....5 Figure 3. Location and plot plan of the AOC 15/5 test site...7 Figure 4: Time series of high-wind-speed start-up (19 m/s)....1 Figure 5: Time series of emergency shut-down....11 Figure 6: Mean and maximum power versus wind speed (1-minute data points)...12 3. Table of Tables Table 1. Test Turbine Configuration and Operational Data...6 2 Wind Turbine Generator System Safety and Function Test Report for the Atlantic Orient 15/5 Wind T Page 2 of 19

4. Disclaimer This report was prepared as an account of work sponsored by an agency of the United States government. The test results documented in this report define the characteristics of the test article as configured and under the conditions tested. Neither the U.S. government nor any agency thereof, nor any of their employees, makes any warranty, express or implied, or assumes any legal liability or responsibility for the usefulness of any information, apparatus, product, or process disclosed, or represents that its use would not infringe privately owned rights. They also do not assume legal liability or responsibility for the performance of the test article or any similarly named article when tested under other conditions or using different test procedures. Neither Midwest Research Institute nor the U. S. government shall be liable for special, consequential, or incidental damages. Reference herein to any specific commercial product, process, or service by trade name, trademark, manufacturer, or otherwise does not necessarily constitute or imply its endorsement, recommendation, or favoring by the U.S. government or any agency thereof. The views and opinions of the authors expressed herein do not necessarily state or reflect those of the U.S. government or any agency thereof. The National Renewable Energy Laboratory (NREL) is a national laboratory of the U. S. Department of Energy (DOE), and as an adjunct of the U. S. government, cannot certify wind turbines. The information in this report is limited to NREL s knowledge and understanding as of this date. This report may not be reproduced without written permission from NREL. 5. Test Objective The objective of the safety and function test is given in the International Electrotechnical Commission s IEC WT1 [1]: The purpose of safety and function testing is to verify that the wind turbine under test displays the behavior predicted in the design and that provisions relating to personnel safety are properly implemented. The IEC WT1 also states: The Certification Body shall verify satisfactory demonstration of the control and protection system functions. In addition, the dynamic behavior of the wind turbine at rated wind speed or above shall be verified by testing if this has not been verified within the scope of the load measurements. 6. Background This test is being conducted as part of the U.S. DOE s Small Wind Turbine Field Verification Project. The primary purpose of this program is to provide consumers, manufacturers, and host site organizations with an independent assessment of the performance and reliability of small U.S. wind turbines. In addition, this test may be used to fulfill the safety and function test requirement identified in IEC WT1 Annex D for wind turbine certification. 3 Wind Turbine Generator System Safety and Function Test Report for the Atlantic Orient 15/5 Wind T Page 3 of 19

Atlantic Orient Corporation developed the AOC 15/5 with assistance from the U.S. DOE and NREL. The test turbine, located at the National Wind Technology Center (NWTC), is owned by NREL and serves several functions, including: o o o o o Developing NREL s certification testing capabilities Participating in an international round-robin testing program Testing wind/diesel hybrid test systems Developing improvements to the design of the AOC 15/5 model Demonstrating modern wind turbine technology. 7. Test Turbine The configuration of the AOC 15/5 wind turbine is shown in Figure 1 and Figure 2. The turbine is a three-bladed, downwind, free-yaw, constant-speed, stall-regulated machine. Rotational energy is converted to electrical power in the nacelle, which contains the gearbox, generator, and parking brake (see Figure 2). The blades were manufactured by Aerpac/Merrifield Roberts. They were designed by M. Zuteck and based on the NREL Thick-series-type (modified) airfoil. Composed of a wood/epoxy laminate, the blades are 7.2 m in length (from root to tip). The assembled rotor has a sweep area 15. meters in diameter. AOC specifies a blade pitch of 3.24 at the tip for the 185 m elevation of the NWTC. This setting causes the power curve to peak at 65 kw. However, the blades were set to.9 for portions of this test to correspond to the standard configuration for installations of 5-Hz turbines at sea level sites. This setting causes the turbine s power curve to peak slightly over 5 kw. The rotor is connected directly to the gearbox low-speed shaft, and the generator is connected to the gearbox high-speed shaft. The rotational speed of the rotor at rated power is 65 rpm. The transmission s gear ratio of 1:28.25 turns the generator at a nominal 18 rpm. The generator is a three-phase, 6-Hz, 48-volt, induction machine rated at 65 kw. The tower is a 24.4-m high, freestanding, three-legged lattice steel structure. The turbine uses three independent brake systems. Tip brakes mounted at the end of the blades provide aerodynamic braking. They use electromagnets to hold them in position. A capacitor/resistor network provides dynamic braking, and a mechanical brake is used for parking the rotor. The controller is a Koyo DirectLogic 25 PLC, which is located in a small control shed at the base inside the turbine tower. The program used by the controller was originally developed in Canada for AOC. For this test, the program was modified by H. Link to increase safety and ease of operation. The program version used during the test is entitled Round Robin 86 (file name Rrobin86). Connection to the grid is via a 48VAC/13.2kVAC transformer located approximately 3 meters from the base of the tower. Table 1 lists configuration and operational data for the AOC 15/5 as tested. 4 Wind Turbine Generator System Safety and Function Test Report for the Atlantic Orient 15/5 Wind T Page 4 of 19

Figure 1. Overall configuration of the AOC 15/5 test turbine. Figure 2. Tower-top configuration of the AOC 15/5. 5 Wind Turbine Generator System Safety and Function Test Report for the Atlantic Orient 15/5 Wind T Page 5 of 19

Table 1. Test Turbine Configuration and Operational Data General Configuration: Make, Model, Serial Number Atlantic Orient Corporation, AOC 15/5, S/N: none (this was the third AOC 15/5 turbine installed) Rotation Axis Horizontal Orientation Downwind Number of Blades 3 Rotor Hub Type Rigid Rotor Diameter (m) 15 Hub Height (m) 25 Performance: Rated Electrical Power (kw) 5 Rated Wind Speed (m/s) 12. Cut-In Wind Speed (m/s) 4.9 Cut-In Wind Speed Dead Band (m/s) 3.6 Cut-Out Wind Speed (m/s) 22.3 Extreme Wind Speed (m/s) 59.5 (peak survival) Rotor: Swept Area (m 2 ) 177 Online Rotational Speed (rpm) 65 Coning Angle (deg) 6 Tilt Angle (deg) Blade Pitch Angle (deg).9 toward feather during loads testing; 3.24 during overspeed testing Direction of Rotation CCW viewed from downwind Power Regulation stall regulation Overspeed Control centrifugal override of tip brake magnets Drive Train: Gearbox Make, Type, Ratio Fairfield/AOC, Planetary, 1:28.25 Generator: Make, Type, Speed, Voltage, Magnatek, 3-phase induction, 18 rpm, 48 VAC, 6 Hz Frequency Braking System: Mechanical (Parking) Brake: Make, Type, Sterns Series 81,, on nacelle aft of generator Location Aerodynamical Brake: Make, Type, Location AOC, electromagnetic tip brakes, at the tips of all blades Electrical Brake: Make, Type, Location AOC, dynamic brake, connected to the tower droop cable at the base of turbine Yaw System: Wind Direction Sensor none Yaw Control Method free-yaw Tower: Type three-legged steel lattice Height (m) 24.4 6 Wind Turbine Generator System Safety and Function Test Report for the Atlantic Orient 15/5 Wind T Page 6 of 19

Control/Electrical System: Controller: Make, Type Koyo, DirectLogic 25 Power Converter: Make, Type none Electrical Output: Voltage, Frequency, Number of 48 VAC, 6 Hz, three phases Phases 8. Test Site The AOC 15/5 wind turbine under test is located at Site 1.1 of the NWTC (hereafter referred to as the test site), approximately 8 km south of Boulder, Colorado. The site is located in somewhat complex terrain at an approximate elevation of 185 m above sea level. Figure 3 shows the location of the test site relative to Boulder and the front range of the Rocky Mountains, as well as a plot plan of the test site including all obstructions for 2 rotor diameters (with topography lines listed in feet above sea level). The meteorological tower is located 37.5 meters from the test turbine at a bearing of 292 true. Figure 3. Location and plot plan of the AOC 15/5 test site. 7 Wind Turbine Generator System Safety and Function Test Report for the Atlantic Orient 15/5 Wind T Page 7 of 19

9. Instrumentation and Testing Procedure 9.1. Instrumentation Limited instrumentation was used for this test. Some data were used from the mechanical loads test. Detail on instrumentation used in that test is given in the mechanical loads test report [Ref 2]. 9.2. Test Procedures Yaw orientation Observations will be made over time for a range of wind speeds. These observations will be written in the logbook. Start-up The start-up procedure consists of the following steps: PLC checks for no faults PLC checks for turbine enabled PLC checks for wind in band (4.9-22.3m/s) All brakes are energized (released) Turbine spins up At 18 rpm (generator), the grid contactor closes. Time series of start-up transients have been collected during the load test. Shut-down There are two shut-down sequences: Normal shut-down Emergency shut-down. Observations of the shut-down sequence (closing and opening of relays) will be made, and time series of shut-downs will be reported. Power production Power production behavior is recorded as part of the power performance test. Any differences from the expected designed behavior will be reported. Power limitation Maximum power versus wind speed collected during the power performance test will be plotted. Speed limitation The turbine has an asynchronous generator and a gearbox. The rotor is thus defined by the grid frequency and the generator slip. If a fault should occur, the PLC monitors the generator speed and will trigger an emergency shut-down if a speed limit is passed. The second means of overspeed protection are the tip brakes. These are designed to open passively by a combination of aerodynamic and centrifugal forces. A test will be conducted to verify that the tip brakes deploy at a safe speed. 8 Wind Turbine Generator System Safety and Function Test Report for the Atlantic Orient 15/5 Wind T Page 8 of 19

Rotor underspeed The PLC monitors the generator speed. If the generator speed drops to 176 rpm for more than 1 seconds or to 15 rpm for more than 2 seconds, the turbine should shut down. Disconnecting the sensor output (wire 72) from Terminal Block 1 (TB 1) will simulate this condition. Grid outage To simulate a grid outage, the manual power switch for the turbine will be opened. The turbine should perform an emergency shut-down. This will be checked by observing relays and tip brakes. Short loss of grid The manual power switch will be opened and closed as quickly as possible. The turbine should go into an emergency shut-down. This will be checked by observing relays and the tip brakes. Generator over temperature Thermostats are embedded in the generator. At high temperatures, these thermostats open, initiating an emergency stop. Wire 17 will be disconnected from TB1 while the turbine is online. Parking brake current If the turbine measures no current on the parking brake circuit, which indicates that the parking brake is likely to be applied, the turbine shuts down. Wire 28 will be disconnected from Actionpak Terminal 4 while the turbine is online. The turbine should shut down. Droop cable over-twist No system is present to prevent droop cable over-twist. No test will be done to determine the damage from droop cable over-twist. Excessive vibration The turbine has no means to detect excessive vibration. Grid monitor The Time Mark grid monitor monitors the grid voltage, frequency, and imbalance. Normally the output of this sensor is high if the grid is within the set tolerances. If the grid monitor gives a low output, the turbine should shut down. The output of the grid monitor (wire 15) will be disconnected from the grid monitor, thus simulating a low output to the PLC. Unauthorized changing of control settings The turbine system will be checked to see whether settings can be changed. Personnel safety: Fall protection A description of the fall arresting system and anchoring points on the turbine will be given. Lock-out for maintenance Locking devices for the rotor and the yaw motion will be applied. Findings will be noted. Electrical safety A visual inspection will be made to determine whether any hazardous situations exist. A qualified electrician will also be asked to look at the electrical system of the turbine. 9 Wind Turbine Generator System Safety and Function Test Report for the Atlantic Orient 15/5 Wind T Page 9 of 19

Lightning protection Description of the lightning protection for the NWTC installation will be recorded. 1. Results Yaw Orientation The turbine tracks wind direction well most of the time. The turbine frequently exhibits high yaw rates over a range of about 3 as it responds to varying wind speed and direction. The turbine occasionally operates upwind. The turbine is stable in that orientation and follows the wind for several hours at a time. At low wind speeds, the yaw bearing occasionally sticks and the turbine is unable to track the wind. Start-Up Figure 4 depicts a time series of a high wind start-up. In the start-up sequence, the brake is released, the turbine coasts up to 18 rpm (generator rpm), and the turbine goes online. 7 35 6 Power Wind speed Generator speed 3 5 25 Wind speed [m/s], Power [kw] 4 3 2 2 15 1 Generator speed [rpm] 1 5-1 2 21 22 23 24 25 26 27 28 29 3 Elapsed Time, sec -5 Figure 4: Time series of high-wind-speed start-up (19 m/s). Shut-Down The Emergency stop button on the control panel was pushed. The turbine shut down immediately. Both dynamic brake relays (M1 and M4) opened. Figure 5 gives a time series of an emergency shut-down in 13 m/s wind. 1 Wind Turbine Generator System Safety and Function Test Report for the Atlantic Orient 15/5 Wind T Page 1 of 19

7 35 6 Wind speed 3 Power Wind speed [m/s], Electrical Power [kw] 5 4 3 2 1 Generator speed 25 2 15 1 5 Rotorspeed [rpm] -1 4 45 5 55 6 65 7 75 8 Elapsed Time, sec -5 Figure 5: Time series of emergency shut-down. Power Production The power production does not show any abnormal behavior, other then the occasional upwind operation. Ten-minute average power is plotted against 1-minute average wind speed in Figure 6. Power Limitation Figure 6 shows the mean and maximum power of the AOC 15/5 as measured from January 2 to July 2. Each data point is based on a 1-minute period. The highest measured instantaneous power was 85 kw. The 1-minute average power peaked at about 56 kw. This indicates that the turbine s power limitation method (stall) works properly. 11 Wind Turbine Generator System Safety and Function Test Report for the Atlantic Orient 15/5 Wind T Page 11 of 19

9 8 mean power maximum power 7 6 Electrical power [kw] 5 4 3 2 1-1 5 1 15 2 25 Wind speed [m/s] Figure 6: Mean and maximum power versus wind speed (1-minute data points). Rotor Speed Limitation A test was conducted to ensure that the tip brakes deploy from centrifugal and aerodynamic forces at a safe rotor speed. The test procedure and results are given in Appendix A. At least one tip brake always deployed at a safe rotor speed, and data indicated that a second tip brake would release at a slightly higher rotor speed. Rotor Underspeed After disconnecting wire 72 from TB1 to simulate a rotor underspeed, the turbine shut down immediately on a speed sensor fault not an underspeed fault. A second test was performed with the turbine online. All three tip brakes were deployed to force an underspeed. The generator speed dropped from 18 to about 177 rpm. It was concluded that the set point of 176 rpm is too low to detect a realistic situation in which the turbine is online and the rotor speed is too low. The set point was changed to 178 rpm. The test was re-run, and this time the shaft negative power flag did go high. However, the timer that delays the shut-down for 1 seconds did not start, and thus the turbine did not shut down. After modifications were made to the PLC code, the test was re-run. This time the turbine did shut down. Grid Outage The grid connection switch was opened. The turbine shut down. Two of the three tip brakes came out. Short Loss of Grid The grid connection switch was opened and closed as quickly as possible (.5-1 sec). The dynamic brake relay 4M opened, but then it closed again. The turbine did not shut down. The test was repeated by 12 Wind Turbine Generator System Safety and Function Test Report for the Atlantic Orient 15/5 Wind T Page 12 of 19

switching slower (1-2 sec). The turbine shut down after two tip brakes came out, and relays 4M and 1M opened. Generator over Temperature After disconnecting Wire 17 to simulate high generator temperatures, the PLC s Turbine Fault Flag (27) correctly went high, and the turbine shut down. Parking Brake Current Wire 28 was disconnected from Actionpak terminal 4. The turbine remained operating and did not shut down. Inside the PLC, the Parking Brake Fault (24) was not set high. It was found that the Actionpak settings were wrong. This was corrected and the test was re-run. During this test, the Parking Brake Fault flag did go high in the PLC. An additional test was performed with the turbine running, and this time the parking brake relay was pulled. The Parking Brake Fault flag did go high, and the turbine faulted and shut down. Unauthorized Changing of Control Settings There are no means to change the control settings on the control panel. A computer with the PLC software has to be connected to change settings. However, no password is required to do so. Grid Monitor Wire 15 was disconnected from the Time Mark grid monitor. Inside the PLC, Flag X2 (grid fault) went high. The turbine shut down. Fall Protection One of the tower legs is equipped with climbing pegs. Along this tower leg, a steel cable is available to attach a fall-arrest device. There are four lifting points on the drive train for positioning, but there are no dedicated anchor points for fall protection. Lock-Out for Maintenance Yaw movement can be prevented with a yaw lock that is engaged at the tower top. The parking brake normally prevents rotor movement; but the rotor can t be locked if the parking brake or generator is removed for servicing. Electrical Safety The electrical system on the NWTC turbine was upgraded to permit use of a 125-amp circuit breaker at the connection of the turbine to the utility grid. The original breaker was rated for 1 amps. This change required NREL personnel to increase the size of the 48-volt wiring in the control panel and the size of the power droop cable. The NWTC turbine now meets NEC requirements. NREL has not evaluated the latest version of the standard AOC 15/5 turbine wiring to verify that the design meets NEC requirements. High-voltage wiring is routed through conduits whenever possible, and electrical boxes are properly labeled with warning signs. Several controls inside the control panel require access for normal inspection and maintenance activities. Originally this panel did not have any protection from accidental contact with 48-volt components. NREL installed acrylic shields to prevent accidental contact with these highvoltage components. The droop cable has no protection for over-twist. If the turbine is not maintained properly, an excessive number of wraps on the droop cable will result in damage to the turbine and the possibility of exposure to energized circuits. 13 Wind Turbine Generator System Safety and Function Test Report for the Atlantic Orient 15/5 Wind T Page 13 of 19

Lightning Protection The electrical system and tower are grounded. No lightning rod is used on the drive train. The blades have no protection from lightning. 11. References 1. IEC WT1 (21-4), International Electrotechnical Commission (IEC), IEC System for Conformity Testing and Certification of Wind Turbines - Rules and Procedures. 2. Wind turbine generator system mechanical loads test report for the AOC 15/5 wind turbine, R. Santos, E. Jacobson, May 15, 2. 14 Wind Turbine Generator System Safety and Function Test Report for the Atlantic Orient 15/5 Wind T Page 14 of 19

APPENDIX A: Overspeed Test A-1 Wind Turbine Generator System Safety and Function Test Report for the Atlantic Orient 15/5 Wind T Page 15 of 19

AOC 15/5 Overspeed Test June 12, 23 Jeroen van Dam Eric Jacobson Hal Link Scott Wilde Objective An overspeed test of the AOC 15/5 was performed as part of the safety and function test. Under certain faulted conditions, the AOC relies on the tip brakes to keep the turbine within the design limits. The overspeed test was designed to show that the tip brakes will deploy at a safe rotor speed. Background Under normal operating conditions, an electromagnet keeps the tip brakes from deploying. If the turbine controller senses a fault or if wind speeds are outside of normal operating conditions, the controller cuts the power to the tip brake electromagnets. However, the rotor speed sensor has failed on occasion. If the sensor fails or if a gearbox failure decouples the generator from the rotor, the controller might not sense an overspeed condition. The combination of aerodynamic forces and centrifugal forces will overcome the magnetic force, and the tips will deploy. The tip brake magnets were originally designed for centrifugal release at 11% of normal operating speed, but there were many nuisance releases of tip brakes with these magnets. AOC increased the strength of the magnets, but the rotor speed at which the stronger magnets would release from centrifugal and aerodynamic forces was never determined. Determination of Latching Force The first step in the test method is to establish the range of release force likely to occur in AOC 15/5 turbines. Tip magnet strength has been found to vary due to magnet manufacturing differences, age, condition of the latching plate, and voltage supply to the tip brake circuit. The AOC User Manual specifies that latching force should be about 6 lb as measured by pulling on the trailing edge of the tip plate. NREL measured the latching force on each of the tip brakes of the AOC 15/5 turbine. We also varied the voltage supply to the tip brake circuit. Figure A.1 shows these results. At normal NWTC grid voltage (12 VAC), the tip latching force is about 67 lbs. Determination of Rotor Speed Needed for Tip Brake Release Modifications to the turbine controller program were required to disable fault protection and normal grid contactor closure during this test. A generator speed sensor that had the necessary range of operation for this test was installed. It was set to de-energize the tip magnet circuit if the tip brakes did not deploy from centrifugal and aerodynamic forces. Based on strength calculations, NREL personnel determined that 12 rpm would be the maximum rotor speed allowed for this test. Measurements were made of generator speed, wind speed, and tip brake circuit voltage. Wind speed was measured using an anemometer mounted on the turbine tower. This was a convenient measurement point, but it yields only an approximate indication of wind speed. This was sufficient for this part of the test, however, because tip brake release is not strongly affected by wind speed. Because of the 6 coning angle of the rotor, the highest stresses on the blades from overspeeding occur at low wind speeds. A-2 Wind Turbine Generator System Safety and Function Test Report for the Atlantic Orient 15/5 Wind T Page 16 of 19

8 7 6 Latching force [lbs] 5 4 3 2 1 2 4 6 8 1 12 14 Voltage [V] Figure A.1. Tip brake latching force as function of the tip voltage measured at the controller (Blade 3). Table A.1 and Figure A.2 show the results of the tip release test. For every run, Table A.1 indicates the tip brake circuit voltage, the corresponding latching force, and observed maximum generator and rotor speed. The tip brake of blade three deployed first for all tests. During one test, the wind picked up enough to cause the rotor to spin up and deploy a second tip (Figure A.3). This test shows that the deploy speed of two of the tips are close to each other. The maximum measured generator speed was 2583 rpm. The 6-Hz version of the AOC 15/5 has a gearbox ratio of 28.25. Thus the maximum rotor speed was 91.4 rpm. Figure A.3 and Figure A.4 give some time traces of rotor speed and wind speed. Conclusion These tests indicate that the tip brakes deploy at safe rotor speeds. Table A.1. Test Results of the Overspeed Test Tip magnet Tip latching Maximum Maximum rotor A-3 Wind Turbine Generator System Safety and Function Test Report for the Atlantic Orient 15/5 Wind T Page 17 of 19

voltage force generator speed speed Test (V) (lbs) (rpm) (rpm) 1 2 17.3 27 73.3 2 4 35.6 2282 8.8 3 6 48.7 2388 84.5 4 8 57.9 2467 87.3 5 1 62.5 2537 89.8 6 11 64.5 2573 91.1 7 12 66.7 2583 91.4 8 125 66.7 2583 91.4 9 124 66.7 257 91. 1 12 66.7 254 89.9 11 11 64.5 254 89.9 12 1 62.5 2523 89.3 13 8 57.9 2477 87.7 14 6 48.7 2441 86.4 15 4 35.6 2335 82.7 16 2 17.3 2113 74.8 17 1 3.3 1527 54.1 18 5 845 29.9 19 5 82 28.4 3 25 Max generator speed [rpm] 2 15 1 5 1 2 3 4 5 6 7 8 Latching force [lbs] Figure A.2. Maximum rotor speed as a function of tip brake latching force. A-4 Wind Turbine Generator System Safety and Function Test Report for the Atlantic Orient 15/5 Wind T Page 18 of 19

3 2 generator speed wind speed second tip deploys 18 25 first tip deploys 16 2 14 Generator speed [rpm] 15 1 12 1 8 6 Wind speed [m/s] 5 4 2-15 -1-5 5 1 15 Time [sec] Figure A.3. Time trace of test 2, tip voltage 4V. 3 2 generator speed wind speed Rotor spinning with one tip out 18 25 16 Generator speed [rpm] 2 15 1 14 12 1 8 6 Wind speed [m/s] 5 4 2-3 -1 1 3 5 7 9 11 13 Time [sec] Figure A.4. Time trace of test 7, tip voltage 12 V. A-5 Wind Turbine Generator System Safety and Function Test Report for the Atlantic Orient 15/5 Wind T Page 19 of 19