UV- TECHNOLOGY. Technical Documentation ELC N6 / ELC N8 / ELC N10

Similar documents
Product Flyer ELC ELECTRONIC LAMP CONTROL

EPS/ELA-Series User Manual EPS/ELA 250W

Electronic Ballast EVG 2000-T

LINEAR LED DRIVERS. ComfortLine Selectable Current (Output Terminal) ComfortLine SELECTABLE CURRENT (OUTPUT TERMINAL)

Compact System NRGS 11-2 NRGS Original Installation Instructions English

LED Driver Compact fixed output

LED Driver Compact fixed output

LED Driver Linear / area dimming industry. Driver LC 150W mA IND sl EXC EXCITE series

1 Safety instructions

1 Safety instructions. 2 Intended use. 3 Product characteristics. 4 Operation. LB management. Universal touch dimmer insert LED

Operating Instructions Bedienungsanleitung Mode d emploi EWB EWB

1 Safety instructions. 2 Intended use. 3 Product characteristics. 4 Operation. System Universal LED dimming insert Standard

www. ElectricalPartManuals. com Instruction Bulletin ALTIVAR FLEX58 TRX Adjustable Speed Chassis Drive Controllers Installation Guide

Operating Manual (Edition 04/2004) sinamics. Braking Module / Braking Resistor SINAMICS G130

& HIGH CURRENT DC POWER SUPPLIES INSTRUCTION MANUAL

User Guide. Lubricus Lubrication System LUB-D1/LUB-D2/LUB-D3/LUB-D4 (24 VDC)

MAKING MODERN LIVING POSSIBLE. Quick Setup VLT FCM 300 Series. Phone: Fax: Web: -

Models. Output current max.* Output Power max. Low Line : VAC High Line: VAC 24 VDC / 12 A 240 W. Back up battery

M A N U A L. Field Current Controller F2.2

Emergency lighting units EM powerled

ZE motor-protective relay Overload monitoring of EEx e motors

LED Driver Linear / area fixed output industry. Driver LCI 65W 150mA 400mA TOP INDUSTRY sl TOP series

Emergency lighting units EM powerled

Operating Instructions (Translation)

MANUAL CONTROL UNIT FOR ROTATING HEAT EXCHANGER. MicroMax. Article no. F IBC control Made in Sweden

LED Driver Linear / area fixed output industry. Driver LCI 100W 350mA 900mA TOP INDUSTRY sl TOP series

99 Washington Street Melrose, MA Fax TestEquipmentDepot.com. Instruction Manual. Model 2831D 4 ½ Digit True RMS Digital Multimeter

LINE CONDITIONERS USER'S GUIDE

User Manual Rittal PMC UPS 6kVA

IBC control. MicroMax MANUAL. With adjustable boost function and threshold value. Since Set of EMC-glands as an option

1 Safety instructions. 2 Device components. Light Management Rotary dimmer. Operating instructions

MAKING MODERN LIVING POSSIBLE. UniLynx Indoor Installation Manual. ULX 1800i ULX 3000i ULX 3600i ULX 5400i SOLAR INVERTERS

Features. LED Driver. RACT09 9 Watt. TRIAC Dimmable. Single Output RACT09- AC/DC Converter

Operating instructions Rotary actuators M135 M140 M150 M180. June 2012 / / EN

LED Driver Linear / area dimming

OWNER S MANUAL Please read this manual before operating your power supply

Operating Instructions

J1000. Compact Inverter Series.

Mounting and Operating Instructions EB 5868/5869 EN

Ex m Solenoid Operator Type 0519

DUAL 60V 20A POWER FLEX POWER SUPPLY INSTRUCTION MANUAL

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2/2-Way Solenoid Valve 2/2-Wege-Magnetventil Électrovanne à 2/2 voies

Matrix APAX. 380V-415V 50Hz TECHNICAL REFERENCE MANUAL

R&S RT-ZC02 R&S RT-ZC03 AC/DC Current Probe User Manual

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2/2-Way Solenoid Valve 2/2-Wege-Magnetventil Électrovanne à 2/2 voies

Operating Instructions

Operating Instructions

ADN-W L 10. Battery Charger. Instruction manual

BODAS Pressure sensor PR3 series 10

CHARGING UNIT DEM 313

FL ballasts Electronic fixed output PC BASIC, 4 28 W PC BASIC

ZB0050 / ZB0051 ZB0070 / ZB0071

INDUS rail /

Operating instructions EWB 200

Figure 1: Device components

Mounting and operating instructions EB 5801 EN. Electric Actuators Type 5801 (Rotary Actuator) Type 5802 (Linear Actuator)

DEVICE STATE/BYPASSED FAILURE OVERLOAD

Appendix: Safety and application notes for... 15

FL ballasts Electronic fixed output. PC BASIC sl, 4 28 W PC BASIC

1 Safety instructions. 2 Device components. Light Management LED touch dimmer insert. Art. No LEDDE. Operating instructions

Contents. Introduction Inspection Notes on Safety Precautions. Chapter 1 Overview Product Overview Names of Parts 2

1 This instrument must only be used by a competent and trained person and operated in strict accordance with the instructions.

1 Safety instructions. 2 Device components. Dimmer push-button/2-way low voltage. Order No. : Operating instructions

Thyristor power controller TE10A. Burst-firing Single-cycle Advanced Single-cycle

Technical Documentation

Power Electronics. Motor brake relay GA 9031 ministop

Pilot-Operated Proportional DC Valve Series D*1FH

2.7. IT system floor-standing distribution cabinet Series -IPS-F

1.Safe testing IMPORTANT:

ROBUST LED DRIVERS. EasyLine Industry. EasyLine INDUSTRY , , , , , , ,

Indoor Linear 50W Driver SI-CU WW

FL ballasts Electronic fixed output

BODAS Pressure sensor PR3 series 10

LED DOWNLIGHTS. Prime K L LED Downlights with Separate LED Driver HIGH QUALITY COB TECHNOLOGY LED DOWNLIGHTS WITH SEPARATE LED DRIVER

M T E C o r p o r a t i o n. dv/dt Filter. Series A VAC USER MANUAL PART NO. INSTR REL MTE Corporation

Technical Manual Electrical Power Supply System T4002

GE FANUC Parts. VersaPoint Power Terminal. Segment Terminal Fused, with Diagnostics 24VDC IC220PWR013. Features. Ordering Information

J1000 D E F I 1000 J1000 J1000 J1000 J1000

RVS-AX Instruction Manual

Motorized roller MRA50

Mounting and Operating Instructions EB 5863 EN. Electric Control Valves. Pneumatic Control Valve

Electrical operating instructions

LED Driver Linear / area fixed output

SINUS K 13. ACCESSORIES Braking resistors APPLICATION TABLES 78/160 INSTALLATION INSTRUCTIONS

Operating instructions Switching cushion with safety function SSG-SK. 1. About this document. Content

SOLSTART Instruction Manual

! CAUTION! Damages on the machine possible.

Operating instruction Refrigerant Valves PS45

REFERENCE MANUAL FORM: MX-TRM-E REL REV MTE

CRE, CRIE, CRNE CRKE, SPKE, MTRE, CHIE 1 & 3 phase

Steering column and sensor

Products Tde Macno. User s Manual BRAKING UNIT. Cod. MP00401E00 V_1.0

Operating instruction and technical description

Mounting and Operating Instructions EB 8111/8112 EN. Series V2001 Valves Type 3321 Globe Valve

Proportional pressure relief valve, directly operated, without/with integrated electronics (OBE)

Low and High Voltage Power Supplies

HS-1000 Fast Low Noise High Voltage Switch

FL ballasts Electronic fixed output

High Frequency SineWave Guardian TM

ESD5500E Series Speed Control Unit

Transcription:

our name is our principle UV- TECHNOLOGY Technical Documentation ELC N6 / ELC N8 / ELC N10 GB eta plus electronic gmbh Lauterstraße 29, D-72622 Nürtingen, Telefon +49 (0) 70 22-60 02-80, Fax +49 (0) 70 22 6 58 54 Postfach 1411, D-72604 Nürtingen, e-mail: info@eta-uv.de Eingetragen unter HRB 724321 AG Stuttgart, USt.-Id.-Nr. DE 146267800 Geschäftsführer: Dr. Peter Schwarz-Kiene

ELC ( Electronic Lamp Control ) is a registered trademark of IST Metz GmbH.

Contents page I Contents 1 Safety... 1 1.1 Definition of Symbols...1 1.2 Safety Advice...1 1.3 Correct operation...2 1.4 Extended use...2 2 Description of functions... 3 3 Installation... 4 3.1 Mounting of casing...4 3.1.1 Back mounting...5 3.1.2 Side by side rack mounting...6 3.2 Connection...8 3.3 Control current connections...12 3.4 Explanations of the control functions for ELC...14 3.4.1 Release relay...14 3.4.2 Control input START...14 3.4.3 Setting lamp power...14 3.4.4 Table: lamp power...15 3.4.5 Earth fault control...16 4 Operation of ELC... 17 4.1 Initial operation...17 4.2 Switching on the ELC...17 4.3 Switching on the lamp...17 4.4 Dimming Operation...18 4.5 Standby Operation...18 4.6 Switching off the Lamp...18 5 Troubleshooting... 19 5.1 Repair ELC...19 6 Technical Data... 20

1 Safety page 1 1 Safety 1.1 Definition of Symbols Stop (Stop Danger). This symbol warns of serious danger of severe injury to persons. It must be strictly observed. Attention (Warning). This symbol indicates information the non-observance of which can lead to extensive damage to property. The safety warning must be strictly observed. Information. This symbol indicates key information on use. Non-observance can lead to failure. 1.2 Safety Advice The ELC must be installed and connected in compliance with existing regulations and practices. This is e.g. EN 60204-1 in Europe. Repairs on the ELC may only be carried out by the manufacturer. The installation and starting up may only be carried out by skilled electricians. Do not open the ELC before it is disconnected from the mains. BEWARE OF RESIDUAL VOLTAGE! The unit may still be live up to three minutes after it has been switched off.

1 Safety page 2 The ELC causes a leakage current greater than 3.5 ma! Safeguarding by means of leakage current protection type A and type AC according to IEC 60755 is not permitted! The ELC operates in principle as a frequency converter and is equipped with a mains filter whose leakage current could activate fuse protection. Contact to the grounding connector must always be ensured. Additional measures must be taken to ensure that there is no danger when touching the appliance. This could be by means of a universal leakage current protection type B, taking into consideration the increased response threshold, or by means of an independent equipotential connection 1.3 Correct operation The ELC is an electrical unit intended to be installed in the switch cabinets of industrial high-voltage power installations. It is conceived as an electronic ballast for the operation of lamps intended for this purpose. Any other use is deemed as misuse. The manufacturer will not assume liability for damage resulting from misuse. A pre-requisite for authorised operation of the ELC is the observance of both the operating and maintenance instructions and the safety advice. 1.4 Extended use Extended use beyond the operating specifications as stated is not permitted. The manufacturer will not assume liability if the equipment is used in any other way. The operator acts at his own risk. Any operation beyond the scope of the authorised operation is considered to be misuse.

2 Description of functions page 3 2 Description of functions The electronic ballast ELC is designed to operate medium pressure discharge lamps as described in chapter 6. In contrast to conventional ballasts (inductive lamp ballast or transformer or transformer with transductor), the lamp with an electronic ballast is operated with high frequency (approx. 100 khz). The lamp does not flicker and dimming is infinitely adjustable to a range between 20 % and 100 % of the electric power or to between 15 % and 100 % of the UV radiation respectively. Dimming The possibility of dimming the lamp has two advantages. Firstly the lamp can be switched to minimum load (standby operation) during longer idle times and energy can thus be saved. Secondly the optimum lamp power can be determined and adjusted as appropriate. Power control The ELC offers a high level of lamp power constancy due to its integrated power control. Variations in operating voltage of ± 10 % do not affect lamp power. Ignition device When the lamp is switched on the ELC initiates trigger pulses to fire the lamp; a separate ignition device is not required. Other performance characteristics High level of electrical efficiency. The ELC has a network power factor of > 0.9. It can be operated directly at the network without compensation. The potential-free control inputs allow various lamp conditions such as maximum lamp power, dimming or standby to be set. The digital control inputs are designed for control voltages of between 10 and 30 V AC or DC. Therefore ELC can be easily integrated into the installation s electric system. Lamp current and lamp power are continuously recorded and output as analogous 0-10 V signals. The ELC monitors the lamp cables for earth fault. The potential of both lamp outputs is separated from that of the supply voltage. The ELC is both short-circuit proof and safe in open circuit operation at the lamp output.

3 Installation page 4 3 Installation 3.1 Mounting of casing The ELC must be installed in a control cabinet with at least IP 54 protection (see EN 60529). Operation without a control cabinet or in a control cabinet with a lower degree of protection is not permitted. The ELC may only be installed vertically (control connections at the bottom, power connection at the top) allowing for at least the minimum spacing as shown. No other positioning is possible. The installation possibilities are shown in 3.1.1 and in 3.1.2. The ELC should not be mounted in the immediate proximity of sensitive electronic equipment. An appropriate distance must be maintained to scatter field transformers or other inductors. The flow of cool air in ELC must be safeguarded. The ambient temperature must not exceed the values described in chapter 6!. The switching cabinet has to be air conditioned in consideration of total electrical losses and maximum ambient temperature. If the air conditioning is realised by fans the minimum required air flow is described in chapter 6. The better the cooling situation the higher the expected lifetime. Impure cooling air could affect the functionality of the ELC. This can be avoided by installing a fine air filter.

3 Installation page 5 3.1.1 Back mounting min. 20 min. 20 pin-and-socket connector for control signals min. 20 min. 50 Assembly for instance by gudgeon M6 with distance sleeve Top 500 mm 23 mm 270 mm 23 mm min. 100 min. 100 90 mm 473 mm Lamp feeder cable mains connection 130 mm 319 mm Fig. 1: Assembly of the ELC (all dimensions in mm).

3 Installation page 6 3.1.2 Side by side rack mounting min. 20 pin-and-socket connector for control signals 473 mm min. 100 min. 50 Top min. 100 539 mm 520 mm 23 mm 80 mm M8 (4x) 130 mm Lamp feeder connection mains connection 321 mm Fig. 2 side by side rack mounting with assembly brackets

3 Installation page 7 If side-by-side rack mounting is preferred, assembly brackets and screws can be provided upon request. Attach bracket to the upper surface of the appliance Attach bracket to the underside of the appliance

3 Installation page 8 3.2 Connection L1 L2 L3 N PE L1 L2 L3 out1 out2 earthed lead network side automatic cutout earthed lead for the earthing of lamp assembly cable shield lamp feeder cable The power connections of the ELC are situated on top of the casing. Fig. 3 shows the electrical wiring plan. The lamp feeder cable shielding must be connected to the ELC. To this end the connector has an EMC screw connection (also see: connection lamp cable). If wished, the shielding can also be connected to the lamp unit. lamp assembly Fig. 3: Power connection The connection of mains supply cables and lamp feeder cables must be separated from control cables. Quality standards according to EN 50160 regarding mains frequency, voltage drops, transients etc. are required. The one-phase short-circuit power at the supply point must be 20 times higher than the nominal power of the UV-installation (accordingly the short circuit current has to be 35 times higher than nominal current, alternatively the relative short-circuit voltage has to be 2.8% lower).

3 Installation page 9 Mains connection The mains connection of the ELC is situated at the top right. The cross section of the earthed wire must be at least 4 mm². The three phases must be provided with an automatic cut-out. Fig. 4: Mains supply In order to avoid damaging the terminal pins, please do not exceed the following torque: L1, L2, L3: 0,6 0,8 Nm Grounding conductor: 3,0 4,0 Nm

3 Installation page 10 Connecting the lamp feeder cable The lamp feeder cable must correspond with the cable parameters described in chapter Technical Data. Connector assembly (from left to right) Carrier casing Casing gasket Hood and screws EMC cable gland with plastic insert Preparing the lamp feeder cable: Remove sheath Free metal braid and put over cable sheath Insulate conductor Ferrule the grounding conductor (if applied) 8 60 12 (measurements in mm) Insert cable into the cable gland and bush casing

3 Installation page 11 Do not twist wires additionally Insert wires into the contact chamber so that the insulation is aligned with the tightening nut. When tightening the nut hold the wire in position. Torque: 1Nm (permissible moment für screw driver =1.2 Nm) Hexagon socket (jaw span 2) Connect grounding conductor (if applied) Screw on hood. Recommended orientation: Cable gland in the direction of PIN1 (see picture below) Ensure that the shield evenly covers the plastic inset of the cable gland (360 contact)

3 Installation page 12 Tighten EMC cable gland The lamp feeder cable between the switch cabinet and lamp assembly must be laid in a metal insulating tube. For the correct installation of the lamp assembly and lamp please observe the corresponding manufacturer s instructions. 3.3 Control current connections The control wires are connected to the underside of the casing by means of the connectors. On the underside there are two plug strips (s.fig. 5). The pin connector is to be connected to the plug strip marked Control. The pin assignment is shown in Fig. 6 and Chart 1. All control circuits must be earthed upon installation. Fig. 5: Control connections Pin assignment 1 2 3 4 5 6 7 8 9 10 Start1 Max1 Min1 + 10 V DC 0-10V P-lamp I-lamp ES1 n.c. OK1 START MAX MIN SET VALUE PL IL ES RELEASE Start2 Max2 Min2 GND GND GND GND ES2 n.c. OK2 20 19 18 17 16 15 14 13 12 11 Fig. 6 Pin plug for control of ELC

3 Installation page 13 Designation Pin No. Description Start1 1 Start2 20 Max1 2 Max2 19 Min1 3 Min2 18 + 10 V DC 4 0-10V 5 GND 16, 17 digital control input START digital control input MAX digital control input MIN control voltage analogous control input SET VALUE * 15-30 V AC / DC, between Pin 1 and Pin 20 input impedance = 1 kω potential-free, active high 15-30 V AC / DC, between Pin 2 and Pin 19 input impedance = 1 kω potential-free, active high 15-30 V AC / DC, between Pin 3 and Pin 18 input impedance = 1 kω potential-free, active high for set value potentiometer 5 kω or 10 kω max. 10 ma set voltage between 0 10 V and GND, input impedance > 200 kω control GND** P-Lamp 6 analogous output 0-10 V DC / 1 ma, (1 V 1 kw), Reference: GND GND 15 PL (lamp output) control GND** I-Lamp 7 analogous output 0-10 V DC / 1 ma, (1 V 2 A), Reference: GND GND 14 IL (lamp current) control GND** ES1 8 ES2 13 OK1 10 OK2 11 Relay earth contact ES contact, potential-free RELEASE relay contact, potential-free up to 30 V AC / DC, max. 0,5 A Contact between Pin 8 and 13, closed in operation, opens in the case of fault up to 30 V AC / DC, max. 0,5 A Contact between Pin 10 and 11, closed in operation, opens in the case of fault Chart 1: Control current connection of ELC * PWM coupling upon request ** control GND: all pins designated control GND are internally connected and potential-free.

3 Installation page 14 3.4 Explanations of the control functions for ELC 3.4.1 Release relay The release relay indicates the trouble-free operation of the unit. This means that the relay closes when the ELC (see 4.2) is switched on and remains closed during operation providing there is no defect. A typical defect would be that the lamp does not fire. 3.4.2 Control input START High: lamp is on Low: lamp is off By applying the High signal the lamp is fired and warms up at maximum current until the desired power is achieved (see below). We recommend warm-up at maximum power. After a short time (approx. 2 mins) the full output has been reached and the lamp power can be varied as desired. 3.4.3 Setting lamp power Stepless (infinitely variable) The lamp can be dimmed steplessly from between approx. 20 % to 100 % of the nominal power. The lamp power is set by applying an analog voltage of between 0 V and 10 V to control input SET VALUE. 0 V corresponds to min. power P min (20 % of nominal value) 10 V corresponds to max. power P max (100 % of nominal value) SET VALUE can be controlled manually by means of an external potentiometre. Lampenleistung Lamp power 100% 20 % 0 V 10 V Set value Fig. 7: Control characteristic

3 Installation page 15 Digital: MIN und MAX For certain operation modes the lamp power can be set to Maximum or Minimum independent of the control voltage at SET VALUE. E.g.: Lamp warm-up: maximum power or Standby operation: minimum power To this purpose the control inputs MAX and MIN respectively are set to High, whereby the function MAX has the higher priority. 3.4.4 Table: lamp power SET VALUE MIN MAX Lamp power 0 10 V LOW LOW stepless 0 10 V HIGH LOW Minimum 0 10 V LOW HIGH Maximum 0 10 V HIGH HIGH Maximum Minimum Maximum

3 Installation page 16 3.4.5 Earth fault control The ELC (electronic ballast) has been fitted with an earth fault control system. The ELC is fitted with an earth fault relay ES for the purpose of indicating an earth fault. During trouble-free operation the relay is closed (provided the ELC is connected to the power supply voltage). The earth fault control is also active when the lamp is switched off. The lamp should not be switched on is the relay ES is open. In the case of an earth fault via the isolating resistor R_ error (see Fig. 8) the relay ES opens. Lamp R_error ES 8 13 Control The error is only displayed, the ELC does not switch off the lamp. The error is also not stored by the ELC. In order for the earth fault control to function properly it is essential that it be connected as prescribed, particularly the earth connectors. The relay contact ES (pins 8 and 13 on the control connector) opens when the isolation resistance R_ error drops below approx. 200 kohm. Fig. 8: Earth Fault Control If an earth fault occurs during lamp operation we recommend shutting down the installation rapidly and correcting the error. The lamp must not be started if earth fault has occurred. In order to avoid an unwanted reaction of the earth fault control during faultless operation, the isolation resistance of the lamp cables and all lamp connectors must be greater than 10 Mohm. If the release relay RELEASE (s. 3.4.1) is open the earth fault relay ES will not give clear information! In this case an error message earth fault should not be issued.

4 Operation of ELC page 17 4 Operation of ELC 4.1 Initial operation The operative parameters of the ELC, such as the scope of the trigger pulse when switching on the lamp, is set by the manufacturer. Alterations to the manufacturer s settings can only be carried out by the manufacturer. Adjustment to the internal potentiometer can cause malfunction and damage to the equipment and is therefore prohibited. You always have to ensure that the correct lamp type is used (see chapter 6) and that all wireing is properly connected! 4.2 Switching on the ELC The ELC is switched on by applying the operating voltage. 4.3 Switching on the lamp A HIGH signal is applied to the digital START control input to switch on the lamp. If a HIGH signal has already been given to the digital START control input before the ELC is switched on, then the lamp will not start up. In the case of a power failure, the ELC cannot automatically switch on the lamp when power returns. Before switching on the lamp, a LOW signal must be applied to the digital control input. Turn the ELC on maximum lamp power during the lamp warm-up period. Maximum lamp power can be adjusted as follows: HIGH signal at the digital MAX control input or 10 V control voltage at the analogous SET VALUE control input. During warm-up the lamp power stays at a very low level over a longer period of time and after approximately 60 seconds rapidly increases to its nominal power. The lamp is operated with increased power until the nominal power is reached.

4 Operation of ELC page 18 4.4 Dimming Operation After having reached nominal operation, the desired lamp power can be infinitely adjusted. Lamp power is adjusted via control voltage (0 10 V) at the analogous SET VALUE control input. In this context, 0 V are tantamount to minimum and 10 V to maximum lamp power. The adjustment of lamp power via the analogous SET VALUE control input is only possible if a LOW signal is applied to the digital MIN and MAX control inputs. 4.5 Standby Operation During longer idle times the ELC can be switched to standby operation. The lamp is operated at minimum power but can be brought up to nominal power within a few seconds. Standby operation is set as follows: a HIGH signal at the digital MIN control input or 0 V control voltage at the analogous SET VALUE control input. The warm-up time from standby operation to nominal operation depends on the lamp's ambient conditions. If cooling is too intensive during standby operation, the acceleration time is prolonged. The adjustment of standby operation is only possible if a LOW signal is applied to the digital control input MAX. 4.6 Switching off the Lamp The lamp is switched off by applying a LOW signal to the digital START control input. In order to avoid heat accumulation in the ELC, the operating voltage should be left on for a few minutes. Before restarting, the lamp must be sufficiently cooled down as it cannot be fired otherwise.

5 Troubleshooting page 19 5 Troubleshooting Troubles Possible causes Corrective action No RELEASE after having switched on the ELC. Relay RELEASE open Lamp does not fire after being switched on, and the relay RELEASE opens The ELC is not provided with operating voltage Lamp is switched-on (control input START at HIGH) Fault in ELC Lamp is too hot Lamp not connected Lamp defective Check fuses and voltage of terminals Switch-OFF lamp Contact manufacturer, see 5.1 Let lamp cool down, increased cooling probably required Check plug contacts between ELC and lamp Replace lamp 5.1 Repair ELC Only the manufacturer is permitted to repair the ELC. In case of failure please contact the following address: eta plus electronic gmbh Lauterstraße 29 D-72622 Nürtingen Tel: +49 7022 / 6002-80 Fax: +49 7022 / 65854 e-mail: Info@eta-uv.de

6 Technical Data page 20 6 Technical Data General data ELC mains frequency 50 / 60 Hz tolerance mains voltage nominal voltage ± 10 % recommended air flow 120 m 3 / h per ballast Control range approx. 20-100 % Firing voltage 2000 V / < 1 sek. Protection IP 20 Ambient temperature 0 C to +40 C in operation -20 C to +70 C during storage and transportation, before initial operation leave at least 4 hrs at room temperature Permissible pollution pollution severity 2 according to VDE 0110 Permissible humidity Dimensions (H x W x D) Weight Installation position EMC Safety Leakage current relative atmospheric humidity 80 %, non-condensing approximately 500 x 320 x 130 mm approximately 16 kg only vertical (lamp and power connection at the top; control connections at the bottom) respecting the minimum spacing in 3.1 Verified according to EN 55011 EN 61000-3-3 EN 61000-6-2 Verified according to EN 50178 Leakage current > 3 ma, see Chapter 1 Safety

6 Technical Data page 21 Type specific data Type ELC ELC ELC ELC ELC ELC N6-400-75 N6-480-75 N8-400-80 N8-480-80 N10-400-80 N10-480-80 Power factor typ. 0,95 typ. 0,94 typ. 0,94 typ. 0,94 typ. 0,94 typ. 0,94 Power efficiency typ. 0,96 typ. 0,95 typ. 0,96 typ. 0,95 typ. 0,96 typ. 0,95 Power supply 3 x 400 V 3 x 480 V 3 x 400 V 3 x 480 V 3 x 400 V 3 x 480 V Supply current 9,8 A 8,2 A 13,2 A 10,8 A 16,7 A 13,9 A Max. supply current 10,8 A 9,0 A 14,4 A 11,9 A 18,4 A 15,3 A Line protection* 16 A 16 A 16 A 16 A 25 A 25 A Lamp power 6 kw 6 kw 8 kw 8 kw 10 kw 10 kw Lamp voltage 750 V 750 V 800 V 800 V 800 V 800 V Tolerance lamp voltage ± 7 % ± 7 % ± 6 % ± 6 % ± 6 % ± 6 % *Line protection: 3-channel automatic cut-out characteristic C Lamp feeder cable: approved types and lengths The use of cable types which have not been approved by the manufacturer can lead to malfunction. The possibility of damage to the electronic ballast cannot be excluded. Article no. 8036 40017 8068 Type Lamp feeder cable 1 kv 3 x 2,5 mm² NR + PE Ø 10,5 mm "Y" form 1 kv / 10 m Lamp feeder cable, shielded Ø 10,5 mm Lamp feeder cable 1,6 kv 2x2,5 mm² Ø 10,5 mm ELC ELC ELC N6-400-75 N6-480-75 N8-400-80 ELC ELC ELC N8-480-80 N10-400-80 N10-480-80 5-20 m 5-20 m 5-20 m 5-20 m 5-20 m 5-20 m 10 m 5-20 m 5-20 m 5-20 m 5-20 m 5-20 m 5-20 m The data refers to distance between ELC and lamp.