LPSRK30SP 30A 600V TD Dual Elem Class RK1 Low Peak Fuse

Similar documents
LPSRK100SP 100A 600V TD Dual Elem Class RK1 Low Peak Fuse

Low-Peak 600V Class RK1

LPCC3 3A 600V TD Class CC Low Peak Fuse. Features amperage rating. Dimensions and Weight. Long Description. Manufacturer Information

FRNR A 250V TD Class RK5 Dual Elem Fuse-Fusetron

Low-Peak LPJ Class J 600Vac/300Vdc, 1-60A, dual element, time-delay fuses

N0N A 250V One-Time Class H Fuse

Fusetron FRN-R Class RK5 250Vac/125Vdc A, dual element, time-delay fuses

LKN A 250V Super-Lag Fuse Link. Features amperage rating 200 class Voltage Rating 250. Long Description. Manufacturer Information

FRNR A 250V TD Class RK5 Dual Elem Fuse-Fusetron

BUSSMANN. LIMITRON FNQ-R Class CC 600Vac, A, time-delay fuses SERIES. Technical Data Carton quantity: Catalog symbol: Dimensions - in:

LOW-PEAK Time-Delay Fuses KRP-C Class L 600 Volt A

FLQ4 4A 500V TD CT Midget Fuse. Descriptions 4A 500V TD CT MIDGET FUSE Time Delay Midget Fuse 4 Amp. Manufacturer Information

LENRK/LESRK CLASS RK1 DUAL ELEMENT TIME-DELAY FUSES

FLQ /2A 500V TD CT Midget Fuse. Long Description. Manufacturer Information. Taxonomies, Classifications, and Categories

Low Voltage, Branch Circuit Rated Fuses

Low voltage, branch circuit fuses

BUSSMANN. CUBEFuse Compact Circuit Protector Base (CCPB) SERIES. Technical Data Effective April 2017 Supersedes April 2016

Assembly not available for new installations.

Bussmann 10x38mm Photovoltaic fuses 1000Vdc, 1-30A

Poles 3 Starter Size NEMA 3 NON ALUMINUM LINE TERMINAL, LOAD TERMINAL

Electric vehicle auxiliary fuses 500 Vdc, A

XL Style Photovoltaic Fuse Links for Solar Panel Applications 50 to 630A, 1000 & 1500Vdc PV Series

Bussmann series Quik-Spec Power Module Switch elevator disconnect

Compact Circuit Protector (CCP)

General Purpose US Fuses

NH DIN Dual Indication Fuse Links Class am, 690Vac, 6 to 500 Amps, Sizes 000 to 3 NH Series

Compact Circuit Protector (CCP)

Fast-acting supplemental fuse. For superior protection, Bussmann recommends upgrading to Low-Peak Class CC fuses. See data sheet # 1023.

CS-3 SERIES E-RATED/MEDIUM VOLTAGE FUSES

Compact Circuit Protector (CCP)

Compact Circuit Protector (CCP) 1-, 2- and 3-pole Class CC, Midget, 10x38mm

British BS 88 Fuses. High Speed Fuses. Introduction. General Information

Miniature Circuit Breakers

Compact Circuit Protector (CCP)

Up to 60 A Class R 250 V and 600 V ferrule power distribution fuse blocks

5 x 20mm Fuses S500 Series, Fast-Acting, Glass Tube

Accessories. For product data sheets, visit

CL-14 SERIES E-RATED / MEDIUM VOLTAGE FUSES

Ferrule fuses. High Speed Fuses

CUBEFuse. CUBEFuse catalog numbers (amps)

BH-1 modular fuse blocks, 700 V, 400 A

Compact Circuit Protector (CCP)

UL Recognized power distribution blocks

BUSSMANN. Pre-production and sample electric vehicle power fuses 500 Vdc, A SERIES. Technical Data Effective December 2018.

Class R 250V and 600V modular ferrule and knifeblade fuse blocks

Low-Peak fuses offer the industry s most advanced circuit protection

Compact Circuit Protector

A240R/A480R/A072F/A072B MED. VOLTAGE FUSES / R-RATED

FUSES 8.1. Questions? Answers at Western US: CED-ELEV

6.3 mm reverse quick connect

PT Medium voltage fuses for potential and small power transformers

E-RATED/MEDIUM VOLTAGE FUSES

Effective December 2015 Supersedes September 2013

Selection and application guide

Recommended Procedures

Ω 1 Ω Supplementary Fuses

BUSSMANN. 8.3kV E-Rated SERIES. Medium voltage fuses for feeder circuit, switchgear and transformer. protection. Technical Data 10352

High Speed Fuses. Section Contents Page

Class gg/gl, 690Vac, 2 to 500 Amps, Sizes 000 to 3 NH Series

Quik-Spec Coordination Panelboard Specifications

A240R/A480R/A072F/A072B MED. VOLTAGE FUSES / R-RATED

KLKD SERIES 10x38 FUSES

Class J modular ferrule and knifeblade fuse blocks

CH120CAFPN 1P 20A 120 Combo Arc Fault PN Breaker

CHCC_ (Class CC) CHM_ (UL midget/iec 10x38) CHPV_ (13/32 x 1-1/2 and 10x38 photovoltaic)

Amp-Trap 2000 Fuses FOR TYPE 2, NO DAMAGE CIRCUIT PROTECTION IN ALL THE CONFIGURATIONS YOU NEED. Class J / AJT...A2. AJT Reducer Fuses...

Bussmann. Circuit Protection Solutions

Volume 4C: Circuit Protection Bussmann series solutions

SW Tog DP 30A 120/277V Autogrd B&S WH

General Data Dimensions (Inches) Bussmann

Non-fusible. Non-fusible disconnect switches 16A 3150A, 600VAC A, 1000VDC. International acceptance. Disconnect switches.

The easiest and fastest way to select and specify the right fuse

24.4. Miniature Circuit Breakers and Supplementary Protectors. For Immediate Delivery or Tech Support call KMParts.com at (866)

Bussmann series Quik-Spec Coordination Panelboard

BUSSMANN. Next generation Compact Circuit Protector (cat. no. CCP2) SERIES. For use with Class CC, Supplemental and IEC 10x38 mm fuses

C E R T I F I C A T E O F C O M P L I A N C E

UL248 North American Low Voltage Fuses

A. Provide a complete system of overcurrent protective devises as indicated on the drawings, and as specified herein.

CHCC_ (Class CC) CHM_ (UL midget/iec 10x38) CHPV_ (13/32 x 1-1/2 and 10x38 photovoltaic)

Control Circuit Protection

MS303DS MS-303 3P Man CNT Only. Features. Dimensions and Weight. Long Description

Fuseology. Dual-Element, Time-Delay Fuse Operation

TA Ta VA CTRL-XFRMR

CL-14 SERIES E-RATED / MEDIUM VOLTAGE FUSES

Engineering Dependable Protection

APPENDIX E. Electrical System Single Line Diagram Overcurrent Protection Study Overcurrent Protection Device Specifications

Bussmann series IEC cylindrical fuses

www. ElectricalPartManuals. com Engineering Dependable Protection

Now - Up To 400A Mains!

Certi cation Record INDUSTRIAL CONTROL EQUIPMENT Motor Controllers Magnetic

ECET Distribution System Protection. Overcurrent Protection

YOUR ELECTRICAL SYSTEM IS YOUR LIFELINE AMP-TRAP 2000 FUSES

T38 1" T Form 7 Malleable Iron Conduit Body. Material, Color, and Finish Color Gray 0 Zinc Electroplate/Chromate/Epoxy Powder Coat

S200 UL 489 Series. Miniature circuit breakers S200. Features. Description

LH600303C 1/10-30A 3P 600V Class H Box Lug Fuse Block

Protistor size 14x51 ar 690VAC (IEC) / 700VAC (UL)

Section Contents. Disconnect Switches

PowerPact Q-Frame Molded Case Circuit Breakers and Switches (Types QB, QD, QG and QJ)

For Type 2, No Damage circuit protection in all the configurations you need. A Amp-Trap 2000 Fuses

ACW Molded-Case Circuit Breaker UL 489 Listed

Transcription:

LPSRK30SP 30A 600V TD Dual Elem Class RK Low Peak Fuse Catalog Number Manufacturer Description Weight per unit Product Category LPSRK30SP 30A 600V Class RK Low Peak Dual Element, Time Delay Fuse 600 (lbs/each) Dual Element Features amperage rating 30 class RK- connection Ferrule End X Ferrule End element Dual interrupt rating 300000 Amp (RMS Symmetrical), 0000 Amp (DC) Response Time 8 S at 500% Voltage Rating 600//300 Dimensions and Weight Size Descriptions Description Long Description Product Type special features 0.8 In Diameter X 5.00 In Length Manufacturer Information Brand GTIN 000572548366 Manufacturers Part Number LPS-RK-30SP sub brand Low-Peak UPC 0572548366 Taxonomies, Classifications, and Categories Category Description Fuses & Fuse Accessories Type Current Limiting, Time Delay Packaging Carton Package Weight Per each 6 30A 600V TD DUAL ELEM CLASS RK LOW PEAK FUSE 30A 600V Class RK Low Peak Dual Element, Time Delay Fuse Low-Peak Dual Element Electrically Isolated End Cap

Uses, Certifications, and Standards Application standard Large Distribution Switchboards, Power Panelboards, Motor Control Centers, Machinery Disconnect Switches UL, CSA C22.2, CE

Low-Peak 600V Class RK LPS-RK 600Vac/300Vdc, -60A, Dual Element, Time-Delay Fuses Dimensions - in 5" (± 0.3) 5.5" (± 0.3) Available with easyid open fuse indication / to 30A 0.8" (±0.008) 35 to 60A.06" (±0.008) Description: Ultimate protection Class RK dual element, current-limiting, time-delay fuses available with optional open fuse indication on select ratings. Time-delay seconds (minimum) at 500% of rated current. Catalog Symbol: LPS-RK-(amp)SP (non-indicating) LPS-RK-(amp)SPI (indicating) Rating: Volts 600Vac, 300Vdc Amps -60A IR 300kA Vac RMS Sym. 0kA DC Agency Information: CE, UL Listed, Guide JDDZ, File E4273 CSA Certified, Class 422-02, File 53787 Class RK per CSA C22.2, No. 248.2 Catalog Numbers (amps) Non-indicating fuses LPS-RK- SP LPS-RK- 2SP LPS-RK-4 2SP LPS-RK-7 2SP* LPS-RK- 2 SP LPS-RK- 6 SP LPS-RK-5SP LPS-RK-20SP* LPS-RK- 3 SP LPS-RK- 8 SP LPS-RK-5 6 SP LPS-RK-25SP* LPS-RK- 4 SP LPS-RK-2SP LPS-RK-6SP* LPS-RK-30SP* LPS-RK- 2SP LPS-RK-2 4SP LPS-RK-6 4SP* LPS-RK-35SP* LPS-RK- 6 SP LPS-RK-2 2SP LPS-RK-7SP* LPS-RK-40SP* LPS-RK- 8 SP LPS-RK-2 8 SP LPS-RK-8SP* LPS-RK-45SP* LPS-RK-SP LPS-RK-3SP LPS-RK-9SP* LPS-RK-50SP* LPS-RK- 8SP LPS-RK-3 2 SP LPS-RK-SP* LPS-RK-60SP* LPS-RK- 4SP LPS-RK-3 2SP LPS-RK-2SP* LPS-RK- 4 SP LPS-RK-4SP LPS-RK-5SP* * Open fuse indication available by inserting the suffix I, e.g., LPS-RK-5SPI. Requires 75Vac minimum voltage. Carton Quantity: Amp Rating Carton Qty. 0 60 Features: Industry's only UL Listed and CSA Certified fuse with a 300kA interrupting rating that allows for simple, worry-free installation in virtually any application. Fast short-circuit protection and dual-element, time-delay performance provide ultimate protection. Reduces existing fuse inventory by up to 33% when upgrading to Low-Peak fuses. Consistent 2: ampacity ratios for all Low-Peak fuses make selective coordination easy. Time-delay permits 30% FLA sizing for back-up motor protection. Current-limitation protects downstream components against damaging thermal and magnetic effects of short-circuit currents. Protects against single-phase motor damage. Proper sizing can provide "no damage" Type 2 coordinated protection for NEMA and IEC motor controllers. Applications: Feeder and Branch Circuits Motors Transformers Solenoids General Purpose Circuits Recommended Fuse Blocks Fuse Amps -Pole 2-Pole 3-Pole 0-30 R60030- R60030-2 R60030-3 35-60 R60060- R60060-2 R60060-3 For additional information on the R600 Series of 600 volt fuse blocks, see data sheet #. Fuse Reducers For Class R Fuses Equipment Desired Fuse Catalog Numbers Fuse Clips (Case) Size (Pairs) 600V 60A 30A NO.663-R 0A 30A NO.26-R 60A NO.66-R 200A 60A NO.626-R For additional information on Class R fuse reducers, see Data Sheet 8. 083 BU-SB3684 Page of 3 Data Sheet # 0

Low-Peak 600V Class RK LPS-RK 600Vac/300Vdc, -60A, Dual Element, Time-Delay Fuses Time-Current Characteristic Curves Average Melt to Amps 300 5 0.2 0.3 0.4 0.5 0.6 0.8.25.6 2 2.5 3.2 4 5 6.25 8 AMP RATING 0 TIME IN SECONDS 0.0 CURRENT IN AMPS 0 00 083 BU-SB3684 Page 2 of 3 Data Sheet # 0

Low-Peak 600V Class RK LPS-RK 600Vac/300Vdc, -60A, Dual Element, Time-Delay Fuses Time-Current Characteristic Curves Average Melt Current-Limitation Curves 2 to 60 Amps 400,000 300,000 200,000 B AMP RATING INSTANTANEOUS PEAK LET-THROUGH CURRENT IN AMPS 0,000 90,000 80,000 70,000 60,000 50,000 40,000 30,000 20,000,000 9000 8000 7000 6000 5000 4000 3000 A 2000 60A 30A 00 00 2000 3000 4000 6000 8000,000 RMS SYMMETRICAL CURRENT IN AMPS A-B = ASYMMETRICAL AVAILABLE PEAK (2.3 X SYM RMS AMPS) 20,000 30,000 40,000 60,000 80,000 0,000 200,000 300,000 Current-Limiting Effects Prosp. Let-Through Current S.C.C. (Apparent RMS Symmetrical Vs. Fuse Rating) 30A 60A 00 00 00 2000 00 00 3000 00 00 5000 00 2000,000 00 2000 5,000 00 2000 20,000 2000 3000 25,000 2000 3000 30,000 2000 3000 35,000 2000 3000 40,000 2000 3000 50,000 2000 3000 60,000 2000 4000 70,000 2000 4000 80,000 2000 4000 90,000 2000 4000 0,000 2000 4000 50,000 3000 5000 200,000 3000 5000 250,000 3000 6000 300,000 3000 6000 The only controlled copy of this Data Sheet is the electronic read-only version located on the Bussmann Network Drive. All other copies of this document are by definition uncontrolled. This bulletin is intended to clearly present comprehensive product data and provide technical information that will help the end user with design applications. Bussmann reserves the right, without notice, to change design or construction of any products and to discontinue or limit distribution of any products. Bussmann also reserves the right to change or update, without notice, any technical information contained in this bulletin. Once a product has been selected, it should be tested by the user in all possible applications. 083 BU-SB3684 Page 3 of 3 Data Sheet # 0