Application and Design W x H Construction Standard Optional Frame Material Galvanized Steel - Frame Material Thickness External Minimum Size 16 ga. (1.5mm) Internal Single Section Maximum Size Multiple Section* Inches 6 x 6 12 x 8 48 x 74 144 x 148 mm 152 x 152 305 x 203 1219 x 1880 3658 x 3759 * For sizes larger than listed, consult factory. 12 ga. (2.7mm) 14 ga. (2mm) Frame Type 5 in. x 1 in. hat channel - Blade Material Extruded Aluminum - Blade Type Airfoil - Blade Action Parallel - Linkage Axle Bearings Plated steel out of airstream, concealed in jamb Synthetic (acetal) sleeve type 304SS Axle Material Plated steel 304SS Blade Seals TPE Silicone Jamb Seals 304SS - Sleeve 12 in. (305mm) 12 in. - 48 in. (305mm - 1219mm) Sleeve Gauge 20 ga. 14 ga. or 16 ga. Flange Air Straightener Actuator None Polycarbonate Honeycomb 24 VAC 50/60 Hz 1 1 2 in. (38mm); Upstream side, Downstream side, Both Sides - 24 VAC w/ auxiliary switches or manual quadrant *W & H dimension furnished approximately 1/4 in. (6mm) undersize. Blade Overlap Blades overlap to provide added resistance to leakage. When pressure increases, the blade seals are forced together creating a tighter seal. Air Measuring Station with VCD-42 Control Damper The combines the functionality of an accurate airflow measuring station and a low leakage control damper into one compact assembly that both measures and regulates airflow volumes to a target set-point. The comes standard with a modulating actuator and a properly sized pressure transducer that output a signal proportional to cfm. A field supplied controller can then use the transducer's signal along with the flow formula: CFM = Area * K * (P transducer ) m to regulate the modulating actuator to the target set-point. K & m are factory supplied variables specific to each damper. Ratings Velocity: Leakage: 300 to 3000 fpm (1.5-15.2 m/s) 6 cfm/ft 2 @ 4 in. wg (110 cmh/m 2 @ 1 kpa) 3 cfm/ft 2 @ 1 in. wg (55 cmh/m 2 @.25 kpa) Temperature: -20 F to 180 F (-29 C to 82ºC) Consult factory for temperature lower than -20 F (-29 C) Transducer Temperature: 0 F Airflow Monitoring Accuracy: 5% of reading Features & Control Options 24 VAC modulating actuator mounted externally or internally (NEMA 2) Factory supplied 0-10 VDC pressure transducer Clean wrap Retaining Angles Installation instructions available at www.greenheck.com
Mounting Styles and Specifications Flange on Upstream Flange on Upstream Flange on on Upstream Downstream Flange on Downstream F Airflow Direction Leakage Data VCD-15 VCD-42/43 Damper leakage (with blades fully closed) varies based on the type of low leakage seals applied. Model -TD is available with silicone blade seals and stainless steel jamb seals. Leakage testing was conducted in accordance with AMCA Standard 500-D and is expressed as cfm/ft 2 of damper face area. All data has been corrected to represent standard air at a density of 0.075 lb/ft 3 (1.201 kg/m 3 ). Static Pressure Difference 5.0 4.0 3.0 2.0 1.0 0.9 0.8 0.7 0.6 0.5 0.4 0.3 Static Pressure Difference 8.5 8.0 7.0 5.0 4.0 3.0 2.0 1.0 0.9 0.8 0.7 0.6 0.5 0.4 0.3 0.2 0.2 1 2 3 4 5 6 7 8 9 10 20 30 40 50 60 70 80 90100 150 Air Leakage (cfm/ft 2 ) 1 2 3 4 5 6 7 8 9 10 20 30 40 50 60 Air Leakage (cfm/ft 2 ) VCDR-53 VCD-20 8. 5 8 7 6 5 15.0 10.0 9.0 8.0 7.0
This pressure drop testing was conducted in accordance with AMCA Standard 500-D using the three configurations shown. All data has been corrected to represent standard air at a density of 0.075 lb/ft 3 (1.201kg/m 3 ). Actual pressure drop found in any HVAC system is a combination of many factors. This pressure drop information along with an analysis of other system influences should be used to estimate actual pressure losses for a damper installed in a given HVAC system. AMCA Test Figures Figure 5.2 Illustrates a ducted damper exhausting air into an open area. This configuration has a lower pressure drop than Figure 5.5 because entrance losses are minimized by a straight duct run upstream of the damper. D 4 (W) (H) 3.14 Figure 5.3 Illustrates a fully ducted damper. This configuration has the lowest pressure drop of the three test configurations because entrance and exit losses are minimized by straight duct runs upstream and downstream of the damper. 6D Figure 5.5 Illustrates a plenum mounted damper. This configuration has the highest pressure drop because of extremely high entrance and exit losses due to the sudden changes of area in the system.
Data AMCA 5.2 500 0.05 500 0.01 500 0.01 1000 0.18 1000 0.05 1000 0.04 1500 0.43 1500 0.12 1500 0.09 2000 0.76 2000 0.22 2000 0.17 2500 1.19 2500 0.34 2500 0.26 3000 1.71 3000 0.49 3000 0.38 3500 2.33 3500 0.66 3500 0.51 4000 3.04 4000 0.87 4000 0.67 500 0.01 1000 0.01 1500 0.14 2000 0.25 2500 0.39 3000 0.57 3500 0.77 4000 1.01 500 0.03 1000 0.11 1500 0.25 2000 0.44 2500 0.69 3000 1.00 3500 1.36 4000 1.78 AMCA 5.3 6D 500 0.03 500 0.01 500 0.01 1000 0.12 1000 0.03 1000 0.02 1500 0.28 1500 0.06 1500 0.05 2000 0.49 2000 0.11 2000 0.08 2500 0.77 2500 0.17 2500 0.13 3000 1.11 3000 0.24 3000 0.19 3500 1.51 3500 0.33 3500 0.26 4000 1.98 4000 0.43 4000 0.34 500 0.01 1000 0.04 1500 0.09 2000 0.16 2500 0.25 3000 0.36 3500 0.49 4000 0.64 500 0.02 1000 0.06 1500 0.14 2000 0.25 2500 0.39 3000 0.57 3500 0.77 4000 1.01 AMCA 5.5 500 0.07 500 0.04 500 0.02 1000 0.28 1000 0.17 1000 0.12 1500 0.62 1500 0.37 1500 0.28 2000 1.11 2000 0.66 2000 0.50 2500 1.73 2500 1.04 2500 0.78 3000 2.50 3000 1.50 3000 1.13 3500 3.41 3500 2.04 3500 1.53 4000 4.45 4000 2.66 4000 2.01 500 0.03 1000 0.18 1500 0.40 2000 0.72 2500 1.12 3000 1.62 3500 2.21 4000 2.88 500 0.05 1000 0.19 1500 0.44 2000 0.78 2500 1.21 3000 1.75 3500 2.38 4000 3.11
Factory Supplied Controls By adding a factory supplied controller AMD series airflow measuring dampers become a turn-key solution for measuring and controlling the flow of air. Go to www.greenheck.com for complete instructions on these two controllers. Vari-Green Constant Volume Controller Greenheck s Vari-Green Constant Volume Controller is a highly configurable analog based controller. The controller can accept a cfm setpoint either remotely by way of an analog input or locally by using touch sensitive buttons on its cover. The controller then regulates the position of the AMD s actuator to deliver the requested cfm. An analog output on the controller also supplies a signal that is proportional to the real-time cfm. The Vari-Green Constant Volume Controller features a two line backlit LCD display to show the user the current CFM setpoint, the real-time cfm, the current pressure reading, and the AMD s actuator position. Constant Volume Varigreen Damper Controller Specifications Control dampers meeting the following specifications shall be installed where shown on plans as an air monitor station integral to the minimum outside air damper. The air measuring damper shall control the minimum amount of outside air as recommended by ASHRAE Standard 62 or California Title 24. The air measuring damper shall consist of: 16 ga. (1.5mm) galvanized steel hat channel frame with 5 in. (127mm) depth; airfoil shaped, extruded aluminum blades (0.063 in. [1.6mm] thick) with metal blade to blade overlap (seal to seal only contact is not acceptable). Axles shall be 1/2 in. (13mm) dia. plated steel turning in acetal bearings; TPE blade seals for 250 F (121 C) maximum temperature; flexible stainless steel jamb seals; and external (out of the airstream) blade-to-blade linkage. Damper leakage rating to be in compliance with the IECC (International Energy Conservation Code) and not to exceed 3 cfm/ft 2 (55 cmh/m 2 ) at 1 in. wg (0.25 kpa). Testing and ratings to be in accordance with AMCA standard 500-D. Basis of design is Greenheck model. Copyright 2017 Greenheck Fan Corporation Rev. 9 February 2017