Helical Flow. HF-GC/GP Series

Similar documents
SRT1000 Series THERMAL FLOWMETER

THT-500-A/R INSTRUCTION MANUAL TEMPERATURE AND HUMIDITY TRANSMITTER

2-Color Display Digital Pressure Switch. Rated Pressure Metal Body Type (ISE75H) 2-color digital. Functions

/OVAL OPERATION MANUAL. Eggs DELTA Pulse. Vortex Flow Monitor MODEL : FLP? L A G 1 2 FLP? L?

ITVX Series. Stepless control of air pressure proportional to an electrical signal. Supply pressure: 5.0 MPa

Related vacuum products

2-Color Display High-Precision Digital Pressure Switch

PFA Eddysonic flowmeter

DPC-100 Series INSTRUCTION MANUAL WIRING I/O CIRCUIT DIAGRAMS PART DESCRIPTION

Series ZSE30/ISE30. High Precision, 2-color Display Digital Pressure Switch. With One-touch fittings are newly introduced. PSE

2-Color Display Digital Pressure Switch. NPN/PNP open collector 2 outputs added. Cut-to-zero display function added. Rated Pressure Metal Body Type

Digital display Pressure range ON/OFF output Linear output Model

Positive displacement flowmeter for continuous flow measurement

Model Pressure range ON/OFF output Linear output

* E8MS-N1 is only 1-channel pressure sensor controller. E80-C2 can be used. For more details, please refer to E80 catalogue.

Operating Instructions for Oval Wheel Flowmeter. Model: DOC

FPD1000-HP SERIES HIGH PRESSURE Positive Displacement Flowmeters

TOWA SEIDEN INDUSTRIAL CO., LTD.

Vacuum pump system type

OVAL GEAR FLOWMETER ELECTRONIC MODEL 019 / ¾

Low Differential Pressure Sensor ±1% F.S.

VSG Series Features Descriptions VSG VSG VSG Descriptions Supply valve Descriptions Vacuum filter

Series ITV0000. Compact Electro-pneumatic Regulator ITV N. IITV00 02 n. How to Order F.R.L. AV AU AF AR IR VEX AMR ITV IC VBA VE VY1 G PPA AL

FPD1001 thru FPD1003, FPD1102 and FPD1103, FPD1201 thru FPD1203 (includes -R Option) Positive Displacement Flowmeters

NO ENTRY No entry for Models 605, 610 or 620. Enter maximum flow rate for Model 600 with external flow sensor

To avoid injury, death of personnel ordamage to instrument, the operator must refer to an explanation in the User smanual.

How to Order BS B. Nil. Bracket (End bracket, Center bracket) Nil

Pressure sensor with built-in amplification and temperature compensation circuit

Model Pressure range ON/OFF output Linear output

2-Color Display High-Precision Digital Pressure Switch Series ZSE40A(F)/ISE40A

OVAL GEAR FLOWMETER ELECTRONIC MODEL 006/009 (¼ )

INLINE Flow sensor for hazardous area II 1 G/D - II 2 D - II 3 GD - I M1

Ordering Information. Application Example. New General-purpose Incremental-type. Rotary Encoder. Accessories (Order Separately)

Series ITV. Electro-pneumatic Regulator Electronic Vacuum Regulator F.R.L. AV AU AF AR IR VEX AMR ITV IC VBA VE VY1 G PPA AL

MULTI FUNCTIONAL COUNT CHECKER MODEL Poka Patrol CNA-4mk3

Head-separated Digital Pressure Sensor DP5 SERIES DPH SERIES

Flow sensor for compressed air

Inline Ultrasonic Flowmeter

Cat. No. I526-E1-1 USER S MANUAL 3G3IV-PLKEB2 /4. Braking Resistor Units 3G3IV-PCDBR2 B/4 B. Braking Units

Digital Flow Switch (Sensor Part) Operation Manual

High Accuracy Eddy Current Type Displacement Sensor GP-A SERIES. Resolution 0.04 % F.S., Linearity ±0.5 % F.S., IP67G environment resistance

OPERATION MANUAL. Digital Flow Switch DFS3 Series. Manufacturer : Taiyo Ltd. <URL:

Read and understand this manual for safely usage.

Micro-differential Pressure High-precision Digital Pressure Sensor For Gas DP-M SERIES

HYBRID HYDRAULIC O OIL COOLING EQUIPMENT O-1

Positive Displacement Flowmeters GM020 series instruction manual

2: A, B 3: A, B, Z 4: A, A _, B, B _ 6: A, A _, B, B _, Z, Z _

EX-F70 SERIES EX-F60 SERIES

Series ITV. Electro-pneumatic Regulator Electronic Vacuum Regulator F.R.L. AV AU AF AR IR VEX AMR ITV IC VBA VE VY1 G PPA AL

HS6B Series Sub-Miniature Interlock Switch. Direct Opening

5-Phase Stepper Motor

ITVH Series. 3.0 MPa Maximum Supply Pressure High Pressure Electro-Pneumatic Regulator. 3.0 MPa 0.2 to 2.0 MPa. 3 W or less L /min (ANR)*

Inductive Proximity Sensor

Small size flow controller

OVAL GEAR FLOWMETER ELECTRONIC MODEL 025 / 1

2-Color Display High-Precision Digital Pressure Switch

Integrated Flow Control Module for Slurries and Chemicals LFC-7000

A Member of the. Integrated Metering Technologies

Micro-differential Pressure High-precision Digital Pressure Sensor For Gas DP-M SERIES

Digital display Pressure range ON/OFF output Linear output Model

1. Preface For best results, please refer to this manual before using this product. 2. Safety precautions Model Precautions DFS-1 The maximum pressure

Techcon Systems TS500R-PC Controller For Positive Displacement PC Pump

Electro-Pneumatic Regulator / Electronic Vacuum Regulator

Built-in ZPA Logic Hybrid Driver Card No. HB-508S

Digital Flow Switch (Integrated display type)

Analog Output Terminal

Analog Input Terminal

Electro-Pneumatic Regulator Electronic Vacuum Regulator. Series Model Set pressure range Port size to 0.1MPa to 0.5MPa to 0.

User's Manual. MV100 Rechargeable Battery Model. Yokogawa Electric Corporation. IM MV100-41E 1st Edition

Electric Cylinder. LZB/LZC Series. It can be operated like an air cylinder. LZB Series. LZC Series LEF LEJ LEL LEM LEY LES LER LEH 25A- LEC

2-Color Display Digital Pressure Switch

Positive displacement flowmeter

Insertion magnetic inductive flowmeter

A Member of the. Integrated Metering Technologies

VF-S11 RS485 built-in board option RS4003Z Instruction Manual

R-101-E GLASS TUBE FLOWMETER BEST COST PERFORMANCE GENERAL STANDARD SPECIFICTION. Max. fluid press. MPa Meter size.

Series 10-ZSE40A(F)/10-ISE40A

MODEL MX75 3 OVAL GEAR FLOWMETER

Positive Displacement Flowmeters GM007 series instruction manual

HS6B Series Subminiature Interlock Switch

Operators Manual. Recirculating Chiller /06/08

Technical information for LFU20-Z07-3A-X2

Transmitter CSA-591 Instruction Manual

Type Operating Instructions. Bedienungsanleitung Manuel utilisateur

9.8 mm. Digital Pressure Switch. 3-step setting. RoHScompliant. Series ZSE10(F)/ISE10. Vertical mounting space reduced to approx.! Reduced in depth!

OVAL GEAR FLOWMETER ELECTRONIC MODEL 025 / 1. Type CR for Corrosive Applications

Octave Water Meter Installation Manual

Unit specifications. Nil. Option 1. Power supply/output connection cable. Option 2

Air Trap TATSU2. Copyright 2013 by TLV CO., LTD. All rights reserved ISO 9001/ ISO M-02 (TATSU2) 7 August 2013.

CDT1000 Series QUICK FLOW. Digital Flowmeter for Air Conditioning Application OUTLINE FEATURES STANDARD SPECIFICATION

Differential Pressure Sensor

Applicable Terminal Relay Rated voltage Model G6D-F4B 12 VDC G6D-1A (see note) 24 VDC 12 VDC G6D-1A-AP (see note) 24 VDC G3DZ-F4B 12 VDC G3DZ-2R6PL

20 amps 220 amps, 60 Hz VDC VAC G3PA-420B-VD-2 DC amps 440 amps, 60 Hz G3PA-450B-VD-2 DC12-24

ION JET NOZZLE NIH-55

2-PHASE STEPPING MOTOR DRIVER FE Z5 DISPENSE

Compact Flow Rate Sensor. RAPIFLOW FSM3 Series Resin Body Type. Diversified High Performance. High performance. User-friendly. Compatible CC-1235A 1

Vacuum Switch Diaphragm Style. Specifications

DPS280 / DVS280 Series

Digital Flow Switch. How to Order PF2D C. Port size: (inch) PF2D504 PF2D520 PF2D540

INSTRUCTION MANUAL. Flow sensor FUS20 series HIR

Transcription:

Helical Flow A Helical Flow Type of Screw Revolution Instruction Manual for HF-GC/GP Series (SC and MP/MC Series incld. ) Caution Before use, please read this Instruction Manual thoroughly for safe operation. Please always keep this Instruction Manual at hand for quick reference when necessary. 25-R10

Contents 1. Safety precaution 3 Design precaution 3 Installation precaution 3 Wiring 3 Operating environment 4 Liquids to be measured 4 Flow indications 4 Other applications 4 Requesting and notice 4 2. Greeting 5 General description 5 Accessories 5 3. Product specifications 5 Hall IC sensor specification 6 on amp. at 4-20mA and two contacts output 6 Precaution when installing flowmeter 6 4.Combination with flowmeter and indicator 7 Combination with flowmeter and sensor 7 Explanation on the connecting terminal of the flowmeter 8 Connection of flowmeter and indicator ( EM0100DT/DR and EM1000ET) 8 5.Label contents applied to flowmeter 9 6. Maintenance 9 7. Product specification on HF-GCC (With analog output substrate) 9 8. Product specification on HF- GCB 11 (With flow proving switch substrate) 9. Product specification on HF-GCG 13 ( Type unified with flow indicator) 10. Where to call 15

1. Safety precaution As the Instruction manual includes very important contents in order to use the Warning products properly and in safety, please read thoroughly with caution and follow them. Please always keep this Instruction Manual at hand for your quick reference when necessary. Should you be lost, then please contact us at nearest sales office. Design precaution Never flow solid matters and gaseous matters (including air purging), as the HF-GC/GP/SC and MP/MC series have been designed for the purpose of liquids flow and their flow measurement. If done, it may cause failure or damage. Use the flowmeter under the rated voltage. Use the flowmeter under the rated pressure. Use the flowmeter within the max operating temperature. Always keep inside of the flowmeter tube filled fully with fluid inside the tube. HF-GC/GP/SC and MP/MC series should be for the use in an industrial instrument only and may not be used for any other applications. Installation precaution Be careful to handle, as there is a type which is made of glass tapered tube in the flowmeter. Never mount foot on the flowmeter nor put things on it. If done, it may cause failure or damage. Do not use the flowmeter with immersed in liquids. Install the flow r control valve at the outlet of the flowmeter. If there is a throttle like a valve at the inlet, the liquids inside the flowmeter will drain out and air bubbles (Cavitation) resulted from the reduction of pressure will occur so that it may be disabled for flow measurement. Wiring Wiring shall be carried out after turned off the power supply. Make sure power supply voltage to ensure that power supply input has not exceeded the ratings. In case that devices which will become noise source are used near the flowmeter such as a switching regulator or inverter motor, take steps for the noises to ground the device frame ground(f.g.) and the like. Be sure to do the confirmation of the color of lead wires, when wiring to the flow indicator or sequential controller. Avoid turning on/off the power supply continuously. Do not apply additional pressure and tensile stress in wiring to the terminal block. It may cause disconnection. Do not bind and wire the connecting wires coming from flowmeter together with, in parallel with or wire in the same metal conduit as the heavy current wires such as power supply, power cable, high voltage cable and the like. If done, it may cause malfunction due to the noises placed on signals.

Operating environment Never use the flowmeter in the atmosphere of the explosive gases. Never use the flowmeter in the atmosphere of the corrosive gases. Do not set the flowmeter in places, where condensation of humidity will not occur and while water is spraying, because it is not constructed in water-resistant and humidity-resistant structures. (Use it in a place where is 80% and below in humidity). Set the flowmeter in a place, where is not subjected to the direct ray of the sun and the ambient temperature is between 0 and 50. Use the flowmeter in a place, where it is not affected by the electromagnetic field. Use the flowmeter in a place, where is less mechanical vibration. If affected from outside, it may cause disconnection of the cable and may cause the chattering, and may result in error of flow measurement and occurrence of particles(dust). Liquids to be measured Do not enter foreign matter into the liquids. There may be a case where the viscosity is too high to disable the flowmeter for flow measurement. Be sure to use the flowmeter within the specified temperature of the liquids to flow. Flow indication When purchased both the flowmeter and the flow indicator at the same time, the data necessary to indicate the flowrates are all configured to the indicator at the factory shipment. Only you have to do is to make up pipe and flow water so that the accurate flowrates are displayed on the indicator, provided that the data input directly with no reference to such comparative outputs, unless otherwise specified. are shipped in the initial values. In case where the water is initially run to the pipe (When setting up the systems), air bubbles enter into the inside the flowmeter, and air entrapping occurs accordingly. Air bubbles inside the meter may cause it to read inaccurately and/or malfunction. When setting up systems, eliminate air bubbles by means of running the water around maximum flowrates and fill the inside of flowmeter with water fully. Other applications It shall not be covered by warranty, if the product has been disassembled and reassembled. The product has a serial number of its own. It also shall not be covered by warranty, should any change of the parts be made on the product. Be careful to handle flowmeter, as it is a precision instrument. It may cause leak and damage, if given the shock by falling or something fallen on it. HF-GC/GP/SC and MP/MC Series have only a function to produce pulse signal continuously. Please understand that any supply operation or any automatic flow control cannot be performed in a single unit of this product as such. Requesting and notice and dimensions are subject to change due to improvements without prior notice. Warranty period of the product shall be one year from the date of purchase. (For one year counting

from the next month of the month shipped from factory). During the warranty period, if the fault occurred which is liable to us, we will repair the faulty part or replace it with new one only. A series of the type of HF-GC/GP/SC and MP/MC themselves do not have any control function to protect from disaster and accident. We would like to request you to take into consideration any safety measures on your side for the control devices entirely. Please be advised that we shall not any responsibility for any damages arisen out of the disaster and accident where it has been by chance occurred relating to the devices using these products. 2. Greeting We highly appreciate your purchasing the Helical Flow type of the screw revolution HF-GC/GP/SC and MP/MC Series. We would like to request you to read through the Instruction Manual with caution in order fully to display the performance and to use it safely for many years to come. General description A helical flow type of flowmeter HF-GC/GP/SC and MP/MC Series is a pulse counting flowmeter by Hall element which has been constructed most simple and compactly and in low cost. The flowmeter makes the Hall IC count the revolution of screw(one revolution is two pulse) and take out the pulse signal by using the magnets incorporated into t he inside the screw. The flow indicator receives the pulse signal from the flowmeter and computes and displays the instantaneous and integrated flowrates per one minute according to the sampling time and pulse counting. Accessories Check to ensure that the following is all present. Flowmeter body: ( HF-GC/GP/SC and MP/MC types ) Hall IC sensor: (HF-GCA type) Amp. Box: (HF-GCB and GCC types) Instruction Manual Option Flow indicator Connecting cord (Only in case that the flow indicators are EM0100 DT/DR and EM1000ET) 3. Product specification Output accuracy: Within FS3% HF-MPA30 : 0.5-5 L/min 1-10 L/min 2-20 L/min Output accuracy: Within FS3% HF-GCA30 : 0.5-5 L/min, 1-10 L/min, 2-20 L/min

Max operating pressure 0.5 MPa(G) (In case of MP type: 0.35MPa(G)) Pressure resistance 0.75MPa(G) (Incase of MP type: 0.5MPa(G)) Max operating fluid temperature Max 100(In case of MP type: 55and GCB and GCC: 50) Ambient temperature 0 55 ( Non condensing ) Hall IC sensor specifications Power supply voltage: 5-24VDC Output:: Voltage pulse NPN open collector Current consumption: 10mA and below on amp, 4-20mA output and two contact output Refer to the instruction manual attached separately. Precaution when installing flowmeter Be sure to comply. In making up pipe, fix the flowmeter by using a wrench. Tightening torque for: HF- MP: 784 N cm HF- GC: 1470 N cm The work of piping should be done within the tightening torques as stated above.

4. Combination with flowmeter and indicator If purchased both flowmeter and indicator at same time, check the serial number (Mfg. No.) to ensure that the serial number of flowmeter agrees with that of indicator. If used the flowmeter which is different serial number from that of indicator, it may cause errors of flowrate and indication. The appropriate data have been configured to indicator at factory when shipping flowmeter from factory. If purchased the flowmeter only, check the serial number to ensure that it is securely entered. Combination with flowmeter and sensor Flowmeter typed HF-GC/GP/SC and MP/MC should be used after the flowmeter body has been combined with Hall IC sensor. The flow measurement is not carried out by a single unit of flowmeter body. Combination figure with Hall IC sensor and flowmeter body Screw up Hall IC sensor to the flowmeter with reference to the illustration as shown below. Hall IC sensor shall be screwed up fully to the end. If not screwed up fully to the end, there is a case where the sensor does not operate properly.

Explanation on the connecting terminal of flowmeter Wiring should be made with reference to the illustration as shown below. HF- GC type Orange: Orange:VDC DC V Gray Gray : 0V : 0V White White : Output : Output HF- MP type Orange:VDC Gray : 0V White : Output Cord colors Orange Gray White Functional contents VDC GND Output(Voltage pulse) Connection of flowmeter and indicator ( EM0100 DT/DR and EM1000 ET ) When using any flow indicator other than described above, refer to the Instruction Manual attached separately. EM0100(DT, DR) Cord colors EM1000ET Functional contents Gray Black(Thin) Pulse input terminal Blue Blue Common terminals to input and sensor power supply Brown Brown Sensor power supply (12VDC) Relating to other connections How connections of the flow indicator of EM series to the driven power supply, etc. and the output from flow indicator(analog output, etc.) are made should be wired and connected with reference to the Instruction Manual attached to the flow indicator.

5. Label contents applied to flowmeter FLOW RATE : Indicates the flow ranges of flowmeter. CONSTANT : Indicates the input frequency of the indicator typed EM series, or the values computed the discharge flowrate per pulse in units of ml. TYPE : Indicates the type of flowmeter. SER. No. : Indicates the serial number (Mfg. No.) 6. Maintenance Although HF-GC/GP/SC and MP/MC types have a construction which is much harder to clog with dust than the conventional rotary flowmeter, it should be maintained and cleaned once a year or half the year in order to use more safely. 7. Product specifications on HF-GC (With analog output substrate) General description The analog output substrate for HF- GC outputs the analog output in proportion to the flowrate in sensor in term of the current at 4-20mA. The magnets incorporated in inside the body of flowmeter outputs as a pulse signal which make the revolutions of screw count up by the Hall IC. The cycle period of this pulse output is measured by microcomputer, operated, converted to analog voltage in terms of D-A converter and converted to the current output by V-1 converter. Power supply Voltage Current *12-24VDC 10% Approx 35mA *In case of using HF-GCT, supply the voltage between 15V and 24VDC. Analog output Output ranges 4-20mADC ( - 10VDC ) Output accuracy FS0.5% Load resistance 400and below : Power supply voltage 12-24VDC10% Pulse output Output form Output sink current Max impressed voltage Operating environment Temperature Relative operating humidity Ambient temperature Same output as Hall IC output outputs in open drainage 10mA and below, Vol=1.0V 35VDC and below 0-55 35 85% RH (No dewing) 0 50

Explanation on connecting terminal of the analog output substrate Wiring should be made with reference to the illustration as shown below. Outside input connector(cn1) Connector maker: J.S.T. Mfg. Co., Ltd. Type of connector: S4B-ZR Type of connector pin: SZH-002T-P0.5 Pin No. Names of pins Functional contents 1 D C Input pin for plus side of power supply 2 N C Not connected any 3 0 V Input pin for 0V of power supply 4 N C Not connected any Outside output connector(cn2) Connector maker: J.S.T. Mfg. Co., Ltd. Type of connector: S3B-ZR Type of connector pin: SZH-002T-P0.5 Pin No. Names of pins Functional contents 1 S C O M Common pin to signal output 2 A N O Output pin for analog current output Analog output in proportion to values of instantaneous flowrate 3 P L S Pulse output pin for monitor Outputs same pulse as Hall IC sensor Reference drawing Analog output Pulse output

8. Product specifications on HF-GCB (With flow proving switch substrate) General description Flow proving switch substrate for HF-GCB outputs the compared results to the value of the flow of the sensor and the compared value of the flow which has been preset in terms of the one staged comparative output. The magnets incorporated in the inside of the body of flowmeter makes the revolutions of the screw count up by means of the Hall IC, and outputs as a pulse signal. The cycle period of this pulse output is measured by microcomputer, operated, compared to the comparative value which has been set by the rotary DIP switch and the results are produced in term of a relay contact and transistor NPN open collector. Power source Voltage Current 12 24VDC10% Approx 35mA Comparative output Comparative operation Setting of comparative value Setting ranges of comparative value Comparative output Relay Comparative output Transistor One staged alarm output operation at upper or lower limit Setting in terms of rotary DIP switch 10 100%(when setting at upper limit) Setting resolution: 10% 0 90% (when setting at lower limit) Setting resolution: 10% Kind of contacts: One transfer contact (1 c contact) Contact capacity: 30VDC 0.5A Life span of contact: More than 100000 times(electrically) More than 50 million times(mecanically) NPN open collector output Sink current: 100mA and below, Vol=1.0V Max impressed voltage: 35VDC and below Operating environment Temperature Relative operating humidity Ambient temperature 0-55 35 85% RH (No dewing) 0 50

Explanation on connecting terminal of the analog output substrate Wiring should be made with reference to the illustration as shown below. Outside input connector(cn1) Connector maker: J.S.T. Mfg. Co., Ltd. Type of connector: S4B-ZR Type of connector pin: SZH-002T-P0.5 Pin No. Names of pins Functional contents 1 D C Input pin for plus side of power supply 2 N C Not connected any 3 0 V Input pin for 0V of power supply 4 CP. OUT Transistor comparative output pin Outside output connector(cn2) Connector maker: J.S.T. Mfg. Co., Ltd. Type of connector: S3B-ZR Type of connector pin: SZH-002T-P0.5 Pin No. Names of pins Functional contents 1 RLY-a Output of contact a in comparative output relay (Make contact) 2 RLY-c Output of contact c in comparative output relay (Common contact) 3 RLY-b Output of contact b in comparative output relay (Break contact) Reference drawing 1 2 3 4 CH 1 CH 2 1. D C 2. N C 3. 0 V 4. CPO 1 2 3 1. RLY-a 2. RLY-c 3. RLY-b

9. Product specifications on HF- GCG ( Type unified with flow indicator) General description HF- GCG is a type of flowmeter which is unified with the flowmeter and the flow indicator(digital meter) which has been conventionally used as an optional. The magnets incorporated in the inside of the body of flowmeter make the revolutions of the screw count up by means of the Hall IC, and outputs as a pulse signal. The cycle period of this pulse output is operated in terms of flow indicator and displays instantaneous flowrate. It produces an alarm output in terms of flowrates which has been set by flow indicator. Power source EM0100DT, DR EM1000ET Voltage 24VDC10% 12 24VDC Current 24VDC: 110mA 12VDC: 155mA 24VDC: 75mA Comparative output Comparative operation Alarm output operation at upper / lower limits Setting of comparative value Key switch input setting configuration Setting ranges of comparative value 9 9 9 9 9 Comparative output NPN open collector output EM0100DT Sink current: 100mA and below, Vol=1.3V Max impressed voltage: 35VDC and below Comparative output EM0100DR Relay contact output Kind of contact: One transfer contact ( Contact c) Contact capacity: 35VDC /0.1A(Load resistance) Life span of contact: More than 100000 times (35VDC/0.1A, resistance load) Mechanical life: More than 50 million times Operating environment Temperature Relative operating humidity Ambient temperature 0-55 35 85% RH (No dewing) 0-50 Explanation on connection and their connecting terminal For the connection to rear terminal of HF-GCG, refer to the following illustration. EM0100DT/DR Pin No. Names of pins Functional contents 1 D C Input pin for plus side of power supply 2 N C Not connected any 3 0 V Input pin for 0V of power supply 4 C P 1 Comparative output terminal on CP1. 5 C O M Common terminal to comparative output for CP1 and 2 6 C P 2 Comparative output terminal on CP2.

HF- GCG Rear view (when using EM0100DT / DR ) HF- GCG Rear view ( when using EM1000ET ) When using EM1000ET, wiring should be made by using the cable for special use in EM1000ET from the rear side. For more information regarding flow indicator, refer to Instruction Manual for digital meter.

10. Where to call H e a d q u a r t e r s: 3-17 Minamidaira, 4-chome Hino City, Tokyo 191-0041 Tel: 81-42-593-8811 / Fax: 81-42-593-8812 Tokyo Sales Office: 3-17 Minamidaira, 4-chome Hino City, Tokyo 191-0041 Tel:81-42-592-6111 / Fax: 81-42-592-6112 O s a k a S a l e s O f f i c e: Suite 915, East Exit Station Bldg. 20-14 Higashinakajima, 1-chome Higashiyodogawa ward, Osaka City Osaka-Fu 533-0033 Tel:81-6-4809-0411 / Fax:81-6-4809-0412 Fukuoka Sales Office: 2F K-2 bldg. 8-5 Hakataekiminami, 5-chome Hakata ward, Fukuoka City Fukuoka pref. 812-0016 Tel:81-92-482-2101 / Fax:81-92-482-2102 Sendai Sales Office: Suite 102, Izumi Kankoh bldg. 8-6 Shohgen, 1-chome Izumi ward, Sendai City Miyagi pref. 981-3132 Tel:81-22-218-2451 / Fax:81-22-218-2452 20090331