Nominal sizes: DN 10, 15, 20, 25, 32, 40, 50, 65, 80, 100, 125, 150 Pressure rating: PN 16. Product No. Nominal size Body connection

Similar documents
Operating Instructions

Operating Instructions ROCO Butterfly Valve with SKG Slider-crank Mechanism, with Electric Multi-turn Actuator

INLINE Flow sensor for hazardous area II 1 G/D - II 2 D - II 3 GD - I M1

Application The DA03 serves as indicator of differential. Follow mounting instructions in accordance to application.

Series V2001 Valves Type 3531 Globe Valve for Heat Transfer Oil with pneumatic or electric actuator

Electropneumatic Converters i/p Converters Type 6111 Mounting and Operating Instructions EB 6111 EN

Valve Series V2001 Globe Valve Type 3321 with Pneumatic or Electric Actuator

Operating Instructions. Angle Seat Control Valve. Type 7020

Series V2001 Valves Type 3535 Three-way Valve for Heat Transfer Oil with pneumatic or electric actuator

For double-acting actuators. Crossover-free switching. Safety function in the event of power failure provided by mechanical return spring

Mounting and Operating Instructions EB 5868/5869 EN

3/2 Way Pilot Valve 3/2 Way Solenoid Valve 1 /4" and 1 /2" 5/2 Way Solenoid Valve 1 /4" 6/2 Way Solenoid Valve 1 /4" 5/3 Way Solenoid Valve 1 /4"

BA50E107 Operating Instructions ROCO Butterfly Valve with SKG slider-crank mechanism, with electric actuator

Operating Instructions. Pneumatic Control Valve Low Temperature. Type Series GS3

Series 42 Self-operated Regulators. Type RS Check Valve (backflow protection)

Volumeter. RMG Meßtechnik GmbH. Publication No E

Make sure that no hazardous fumes can build up in the piping and in the meter during commissioning, decommissioning and dismantling.

Magnetic-inductive flow meter for hazardous areas

Solenoid Valves Type 3963

TABLE OF CONTENT. 7-Operating mechanisms of Non-return valve with hydraulic damping cylinder

Series V2001 Valves Type 3531 Globe Valve for Heat Transfer Oil with pneumatic or electric actuator

Volumeter TRZ 03-K PRODUCT INFORMATION. Reliable Measurements of Gas

SITRANS F M flow sensors 711/A and 711/911E

Pressure relief controller V22 D28

Installation and Operating Instructions DDM-DS11 DDM-DS11-MS1 DDM-DS11-MS2

Flap-Type Flow Meter Prall

Series 430 Type 3430 Pneumatic Indicating Controller for Temperature with Capillary Sensor Type 3432 Controller Station Type 3436 Transmitter Module

Operating Guide SBFV (PN16/25) ENGLISH Steel butterfly valve SBFV Page 2. Danfoss VI.IX.A1.02 1

STEEMCO-MAS Flowmeter for Steam

97100 NAMUR. Technical data

Operating and maintenance instructions VAG RETO-STOP Non-Return Valve

Gauges, Sight Glasses and Vacuum Breakers

INSTALLATION INSTRUCTION & TECHNICAL MANUAL FLOWMETER

1/2-2 INSTALLATION INSTRUCTIONS

Operating Instructions Garlock Butterfly Valves DN : mm / 2-24

Absolute pressure gauge with diaphragm

JCM 101 Universal Clamp Couplings

Flowmeters with Float. Flow Measurement of Gases & Clear Liquids with Float Series 6001 & Series 6001/ Measurement Principle.

Series V2001 Valves Type 3535 Three-way Valve for Heat Transfer Oil with pneumatic or electric actuator

Mounting and Operating Instructions EB 8227 EN. Pneumatic Control Valve Type 3331/BR 31a Special version Type 3331/3278. Type 3331 Butterfly Valve

Storage, operating and maintenance instructions for AZ plug valves and Standard valves

Limit Switch Type 3776

Food & beverage. Oil & gas. Water & waste water

BFS-10-O G1/4: BFS-10-O G1/2: BFS-10-O G1: Contact rating: BFS-10-O G1/4

SITRANS F flowmeters SITRANS F C MASSFLO MASS MC1. 4/146 Siemens FI Overview

Operating Instruction

CACCIALANZA & C. S.p.A. ANTINCENDIO SICUREZZA ANTINQUINAMENTO

Diaphragm valve MV 309

SITRANS F C. Flow sensor MC2 4/193. Overview

General Specifications

SITRANS F flowmeters SITRANS F C

CAPACITIVE LEVEL SWITCHES. Capacitive switch catalogue HYC-CSC01 Elect. Iss. 01

Our policy is one of continued research and development. We therefore reserve the right

Design and application

Metal tube variable area flowmeter for gases, liquids and steam

FLUXI 2000/TZ Instruction manual Mode d emploi Betriebsanleitung Istruzioni d uso Manual de instrucciones Installatie voorschrift

k Applications Bourdon tube pressure gauge with switch contacts For the process industry, NS 100 and 160 Models PGS and PGS23.

Limit Switch Type 3776

Standard Valves Series Globe Valves Series Angle Valves Series Way-Valves

Accessories Cable glands

VLF45... Hot Air Valves. Siemens Building Technologies HVAC Products

Metal tube flowmeters. Series SC250. Metal Tube Flow Meters. Series SC250. Variable area flowmeter for liquids, gases and steam

SITRANS F flowmeters SITRANS F C SITRANS F C MC2 4/169. Overview

HERION SERIES Indirect solenoid actuated soft seal

Mounting and Operating Instructions EB 5894 EN. Electric control valves with jet pump. Flanged version of valve with jet pump

Operating manual Vacuum Breaker

RMG Meßtechnik GmbH. Publication No E

VALVES WITH NA ELECTRIC ACTUATOR

HS10S-FA. Water station. Product specification sheet

Assembly and operating Instructions Bypass Flow Meter DST

General Specifications

BUTTERFLY VALVE WITH WELDED ENDS INSTALLATION AND MAINTENANCE MANUAL

Operating and installation instructions

Electrical data Nominal voltage AC V / DC V Nominal voltage frequency

STEEMCO Flowmeter for Steam

Declaration of Conformity as per Directive 97/23/EC

ETP80. Electronic Transmitter for Pressure, Differential Pressure and Level

10 Load and Motor Switchgear

Orifice flowmeter F O N4

Butterfly valves for high temperature series GD(H) - LDK

Mounting and Operating Instructions EB 8111/8112 EN. Valve Series V2001 Globe Valve Type 3321

Elektric actuator MC50/24-C

Coriolis Flowmeters. Coriolis Flowmeters. KCM C-flow series Coriolis mass flowmeter

IOM Manual. IOM Manual. Series 76/77.

ProFlow TO BE REALLY SURE. Vane Meters. Experience in flow measurement. Introduction

YARWAY NARVIK STANDARD DUTY A.T.-TEMP DESUPERHEATER MODEL 38/48

Soft seated butterfly valves

SMB. Assembly and operating instructions Sprinkler measuring orifice SMB/SMB-OE. Sprinkler measuring orifice

Danfoss Butterfly Valve

Mounting and Operating Instructions EB 8222 EN. Type 3310/AT and Type 3310/3278 Pneumatic Control Valves. Type 3310 Segmented Ball Valve

Typical Feed Water Heater Isolation System.

GBV-G Balancing Valves

USERS MA UAL Bellow sealed valve Fig.229, 230, 234, 235 Edition: 1/2008

NARVIK-YARWAY. Heavy Duty A.T. - Temp Desuperheater Model: 18/54 and 28/64

Resistance Thermometers Model TR217, with Spring-Loaded Probe Tip

MZ Instruction manual Mode d emploi Betriebsanleitung Istruzioni d uso Manual de instrucciones Installatie voorschrift

Level Measurement. Point level measurement Capacitance switches. Pointek CLS200 Standard. 4/18 Siemens FI Overview.

Strainer PN 25/40 DN

THE EXPERT IN LEVEL AND FLOW

VALVES WITH SA ELECTRIC ACTUATOR

Transcription:

Operating Instructions ERHARD Flow Indicator 1 Description of Product and Range of Application 2 Design Features Technical Data 3 Performance and Mode of Operation 4 Installation into the Pipeline Mounting 5 Initial Operation 6 Maintenance 7 Drawings with Parts Lists 8 Flow Characteristic Curves 1 Description of Product and Range of Application Nominal sizes: DN 10, 15, 20, 25, 32, 40, 50, 65, 80, 100, 125, 150 Pressure rating: PN 16 Product No. Nominal size Body connection 86227900 DN 10-50 External thread 86227985 DN 10 50 Screwed pipe connection 86227991 DN 10 50 Flanges 86230191 DN 65 150 Flanges ERHARD Flow Indicators (binary transmitters) monitor liquid flows of cooling circuits and lubrication systems in important pipeworks as e.g. in rolling mills, turbine plants, power stations, chemical plants, etc. They visually indicate the flow condition and switch on and off pumps, machines, etc. depending on flow rates via limit positions and additional relays. Furthermore, ERHARD Flow Indicators give visible and audible signals via contacts in the limit positions. ERHARD Flow Indicators are no measuring instruments! February 2004 Page 1 of 7

2 Design Features Technical Data When the flow starts, the blade fixed to the blade shaft is moved against the force of the return spring. Depending on the flow rate, it deflects by 120 (i.e. 100%). For DN 10 to DN 150, this movement is conveyed to a pointer via a continuous trunnion shaft with grooved ring seal. The operating pin fixed to the pointer actuates the electrical contacts. When flow ceases or stops, the return spring moves blade, blade shaft and pointer back into zero position. 3 Performance and Mode of Operation 3.1 Electrical Connection Connect Flow Indicator according to the data indicated on the nameplate and terminal diagram. For intrinsically safe circuit of enclosure (Ex)i, observe VDE 0165, 0170, 0171 and/or DIN EN 50020 and data given on the test certificate for the control device. Connection is done by means of a plug connector to DIN 43651 with BO crimping. The connector piece for the cable is supplied as a separate item. Product No. 8622 and 8623 8638 and 8639 8638 and 8639 Switch type snap-action contact inductive contact inductive contact Enclosure IP 65 (Ex) II 2 G EEx ia IIC T6 IP 65 Switching voltage AC/DC 24 V to 250 V * DC 8V to 15 V DC 10 V to 30 V Switching capacity 30 VA (W) max. 1 A ** 8 ma max. 100 ma * corresponds to VDE 0110 insulating class C ** switch with relay if exceeding 3.2 Contact Adjustment Adjust contacts to corresponding flow characteristic or set them according to the pointer deflection from the outside by means of the setting lock at the centre of the sight glass. The adjustment is technically the same as for the contact pressure gauge. The key for the setting lock is supplied separately. Screw cap back on the setting lock. If the pipeline is subject to heavy concussions, it is possible that contact bounce or contact interruption will occur. In order to prevent faulty switching in this case, a contact protecting relay with delay is to be connected in series or an instrument with inductive contact is to be used. Page 2 of 7

4 Installation into the Pipeline Mounting Remove all packing material from the Flow Indicator. Prior to installation check the pipeline for impurities and foreign matters and clean if necessary. Install the instrument according to the cast-on arrow showing the flow direction into a pipeline section which is free of turbulences. The Flow Indicator can be installed in horizontal or vertical pipeline as the position has no effect on the operation. For vertical downward flow the indicating dial inscribed on both sides should be turned so that the writing is not upside down: Adjust contact pointer to 0%, screw off fastening ring (32), take off sealing ring (31), sight glass (30), tapered ring (29), and indicating dial (28). Insert indicating dial with page 2 on top and turn until pointers point to 0%. For flow media with foreign matters install strainer with mesh size 0.2 mm upstream of the Flow Indicator. It is important that all around the flow indicator there is free access for maintenance and free sight onto the indicating dial. If installed in the open, the customer has to protect the indicator against direct effects of the weather. Install flow indicator with indicating dial in vertical position. Lay the cable in downward direction. Check the seals of the fastening ring (32), the lock (33) and the plug connector (36) for tight seating. If there is the risk of condensation of water in the indicator casing, the Flow Indicator has to be provided wth air release device. In case of design with flanges, please observe the following: During installation of the Flow Indicator, the distance between the pipe ends should exceed the face-to-face dimension of the Flow Indicator by at least 20 mm. Thus, the raised faces will not be damaged and the gaskets can be inserted. Steel-reinforced rubber seals are recommended for use as flange gaskets (consider resistance to flow medium and temperature). The mating pipe flanges must be plane-parallel and concentric. Tighten the connecting bolts evenly (without distortion) and crosswise. The pipeline must not by any means be pulled up to the Flow Indicator. Face-to-face dimension adaptors, if needed, are to be screwed on using sealing compound. Page 3 of 7

5 Initial operation Vent pipe line before commissioning. The Flow Indicator may be charged above the dial range, Q max see catalogue sheet. The pointer is to stand still during operation. If the pointer swivels, install an orifice which produces a counter pressure of approx. 0.1 bars behind the Flow Indicator. 6 Maintenance 6.1 Maintenance The Flow Indicator is maintenance-free. As we have no influence on the condition of the flow medium, however, we recommend to test the performance regularly. Thicker sticking deposits from the flow medium lead to failure of the unit. If water condensates on the inside of the sight glass (30), air has to be evacuated from the indicator body (22). Water condensation is often caused by incorrect storage prior to installation or by subjecting the flow indicator to high temperature fluctuations. Performance test: 1. Does the black pointer return to zero position when the flow stops? 2. Does the electrical contact work? Control e.g. by increasing the switch point. 6.2 Inspection - In case, clean strainer regularly. - Check outside condition of valve. Clean if necessary and repair coating. - Clean sight glass of polycarbonate with soft fabric and if necessary with a nonaggressive cleansing agent. - Check tightness at flanges and screwed joints resp. Page 4 of 7

7 Drawings with Parts Lists Page 5 of 7

Page 6 of 7

8 Flow Characteristic Curves Page 7 of 7