INSTALLATION INSTRUCTIONS MODELS S S S S SSN S SSW SSN SPRINKLER PUMPS

Similar documents
MODEL SS INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS MODEL Z Z Z Z 1.5 HP 115/230V Z Z 2.0 HP 115/230V Z Z

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS MODELS S S SHALLOW WELL & CONVERTIBLE JET PUMPS PAGE 3 PAGE 8

Material required for drilled well application (indoor use only)

Model T Professional Series 1/2HP 2 YEAR WARRANTY SHALLOW WELL JET PUMP

Professional Series 1/2HP 2 YEAR WARRANTY CONVERTIBLE JET PUMP REPAIR PARTS

MODEL P INSTALLATION INSTRUCTIONS

MODEL H INSTALLATION INSTRUCTIONS

MODEL INSTALLATION INSTRUCTIONS. 12 Volt UTILITY PUMP

Professional Séries. Professional Séries. Model T03828 SUBMERSIBLE SUMP DUPLEX SYSTEM SUBMERSIBLE SUMP DUPLEX SYSTEM. 1/3HP 2400 GPH Head of 20 (6 m)

HALLMARK INDUSTRIES INC

3 FT CORD UL/NEC Models , , , FT CORD w/gfci UL Models , , ,

PRESSURE BOOSTER 150

3 FT CORD Models , , , FT CORD W/GFCI Models , , ,

MODELS 108 and 138 CRAWL SPACE PUMPING SYSTEM PREINSTALLATION CHECKLIST

OWNER S MANUAL SELF-PRIMING PORTABLE UTILITY PUMP

OWNER S MANUAL SUBMERSIBLE UTILITY PUMP

PRE-PLUMBED SEWAGE SYSTEM

Owners Manual: - Pumps

OWNERS GUIDE TO INSTALLATION AND OPERATION OF 1/2-5 HP, 5, 7, 10, 15, 19 & 27 GPM 4 SUBMERSIBLE PUMPS

2 Wire Plus Ground 3 Wire Plus Ground IL0655

ESE Series Cast Iron Sewage Pumps

Aqua Ultraviolet Sunami Series Pumps 1/3HP, 3/4HP, 3HP, 4HP, 5HP

Model and Series 115 VAC INDUSTRIAL DIAPHRAGM PUMPS. PumpAgents.com - buy pumps and parts online INDUSTRIAL DIAPHRAGM PUMPS

JET PUMP INSTALLATION MANUAL. motralec SHALLOW WELL JET PUMPS

SELF PRIMING CHEMICAL SERVICE PUMPS

Pump Installation and Service Manual JB-1 System Sewage Ejector Pump Package

LAWN SPRINKLER, IRRIGATION PUMP

SEWAGE PUMP MODEL # Zoeller is a registered trademark of Zoeller Co. All Rights Reserved. Español p. 14

Centrifugal Pumps (Part Nos. PS2SS PS73SS) PS2SS

Please contact your supplier (supplying dealer or contractor) if service is necessary or if you have any questions or need further assistance.

SLR / SLR-S/N. Instruction Manual. Walrus America Inc

SUNC1200 / ITEM #40882 SUBMERSIBLE UTILITY PUMP OPERATIONS MANUAL

Installation Instructions and Parts Manual CPJ SERIES JET PUMPS. Shallow Well Jet Pumps. Convertible Jet Pumps. Ejectors (Purchase separately)

8000 / 10,000 / 12,000

SUNC3000 / Item #40885

Vertical Jet Pumps. SSJ Series. Call OWNER S MANUAL

PSW SHALLOW WELL 1 ¼" 1" All pumps are tested at our factory PERFORMANCE CHART B-1

SHALLOW WELL JET PUMP

Installation & Operating Manual

M-3025CB-AV Fuel Pump

Cascade Owners Manual

STAR STOP SHALLOW WELL JET PUMP

HALLMARK INDUSTRIES INC. Deep Well Submersible Pumps Operating & Installation Instructions

INSTALLATION AND OPERATING INSTRUCTIONS REPAIR PARTS LIST

WELDING FUME EXHAUSTERS & ARMS

OWNER S MANUAL CONVERTIBLE JET PUMP

INSTALLATION AND SERVICE MANUAL

OWNER S MANUAL INSTALLATION AND OPERATING INSTRUCTIONS REPAIR PARTS LIST 60 CYCLE SELF-PRIMING CENTRIFUGAL PUMPS D SERIES MODELS

Electric Fuel Pump FPM

Jet Pumps. Convertible Shallow Well. 6/13 Rev (3/14)

SINGLE-STAGE INJECTOR MODELS 200-3C, 200C, 201C, 202C, 203C, 204C, 206C, 208C

User s Manual D-Series Blowers and Exhausters

W/D/V-A1. Submersible Sump Pump. Pump Installation and Service Manual W-A1 V-A1 D-A1

Grind Pro Series. Operator Manual. Manufacture by:

GRINDER PUMP MODEL # Zoeller is a registered trademark of Zoeller Co. All Rights Reserved. Español p. 13

Commander Pro 100 SUBMERSIBLE SYSTEM Installation, Operation and Trouble-Shooting Manual

End Suction Centrifugal

Series: PFUEG 1/12HP, 5000 RPM, 60 Hz Utility Pumps

Wilo SP Series Submersible Utility Pumps ETT. ETT Installation and operating instructions

GeyserMax-Flow Series

Matala. VersiFlow Series. Instruction and Maintenance Manual

VADA - V60-J PRODUCT OVERVIEW CONSTRUCTION MOTOR USAGE LIMITATIONS WARRANTY

PRO PRO20-115RD 115-Volt AC. PRO Volt AC OWNER'S MANUAL SAVE THESE INSTRUCTIONS

OWNER S MANUAL EVOLUTION 3500, 4500, 5500, & 8500 SERIES PUMPS

Users Manual Professional Series Direct Drive Pump.25-2 GPM Series Safety, Operating, Installation, and Maintenance Instructions

Electric Pressure Washer

Ph: (07) Fax: (07) Pump Manual

Installation & Operating Manual

SPECIFICATIONS SEWAGE/SUMP DUPLEX SYSTEM ZOELLER COMPANY SUBMERSIBLE SEWAGE OR DEWATERING PUMPS

INSTALLATION AND SERVICE MANUAL FOR TURBO-CARB HIGH CAPACITY CARBONATOR

Installation Operation Parts

GARDEN HOSE UTILITY PUMP

DEMA BLEND CENTER MODEL 681GAP-3 INSTALLATION INSTRUCTIONS

D-Series Blowers and Exhausters

M o d e l J E U. Self Priming Jet Pump. Operating Instructions, Installation & Maintenance Manual. Ebara Fluid Handling

INSTALLATION INSTRUCTIONS FOR THE TRUCK MOUNTED VIPER ADDITIVE INJECTION SYSTEM GTP-8776C

Centrifugal Constant Pressure Control

SS/SSH Submersible Pump. Owner s Manual

Installation & Operating Manual

SKHS Series Submersible High Head Sewage Ejector Available Horsepower: 1/2, 1, 1-1/2, 2

Pressure Booster System Models 350 & 351

REPAIR MANUAL 600 SERIES SUBMERSIBLE NON-CLOG UNITS CAUTION

Installation & Operator s Manual

TPH Series. MULTISTAGE CENTRIFUGAL PUMP Instruction Manual WALRUS PUMP CO., LTD. ISO 9001 Certified NSF/ANSI 372

PARTS LIST FOR CM MEH. Copyright 2015, Mi-T-M Corporation

HydraPump Submersible Owner s Guide

DuraMAC LIGHT COMMERCIAL & IRRIGATION WATER PRESSURE BOOSTER SYSTEM INSTALLATION INSTRUCTIONS

barmesapumps.com BP33 & BP & RPM Installation, Operation & Maintenance Manual Submersible Sump / Utility Pumps

2-Speed Pumps Item #s 7813, 7814, 7818 & 7819

Owner s Manual Drill and Light Weight Portable Utility Pumps

DEMA BLEND CENTER MODELS: 637GAP-1 and 637GAP-4 INSTALLATION INSTRUCTIONS

Installation & Operator s Manual

Self-Priming Horizontal Three and Four Stage Pumps

OWNER S TECHNICAL MANUAL OWNER S TECHNICAL MANUAL

6L Oil-less Air Compressor 53103

OWNERS MANUAL INSTALLATION AND OPERATING INSTRUCTIONS REPAIR PARTS LIST

08 general Purpose Pumps

Transcription:

WWW.BURCAM.COM 2190 Boul. Dagenais West TEL: 514.337.4415 LAVAL (QUEBEC) FAX: 514.337.4029 CANADA H7L 5X9 info@burcam.com Your pump has been carefully packaged at the factory to prevent damage during shipping. However, occasional damage may occur due to rough handling. Carefully inspect your pump for damages that could cause failures. Report any damage to your carrier or your point of purchase. Factory set voltage 115 V Connection voltage changing: Before changing the voltage connection: A) Ensure the power to the pump is disconnected. B) Open motor junction box cover. C) Please select the up knob position for 115 V or down knob position for 230 V. or Pull voltage selector knob 1/4 and align arrow with desired connection voltage. D) Push back in voltage selector knob. E) Close motor junction box. INSTALLATION INSTRUCTIONS MODELS 506120S 506220S 503120S 503220S 503220S 506530SSW 506530SSN 506530SSN SPRINKLER SPRINKLER PUMPS PUMPS Please read these instructions Please read carefully. Failure these instructions to comply to carefully. Failure instructions to comply to and designed instructions operation of and designed this system, operation of may void this system, the may void warranty. the warranty. 2011 BUR-CAM Printed in Canada 506200 ILLUSTRATED MODEL 506120S

SAFETY INSTRUCTIONS: This fine pump that you have just purchased is designed from the latest in material and workmanship. Before installation and operation, we recommend the following procedures: A B C D CHECK WITH YOUR LOCAL ELECTRICAL AND PLUMBING CODES TO ENSURE YOU COMPLY WITH THE REGULATIONS. THESE CODES HAVE BEEN DESIGNED WITH YOUR SAFETY IN MIND. BE SURE YOU COMPLY WITH THEM. WE RECOMMEND THAT A SEPARATE CIRCUIT BE LEAD FROM THE HOME ELECTRICAL DISTRIBUTION PANEL PROPERLY PROTECTED WITH A FUSE OR A CIRCUIT BREAKER. WE ALSO RECOMMEND THAT A GROUND FAULT CIRCUIT BE USED. CONSULT A LICENSED ELECTRICIAN FOR ALL WIRING. THE GROUND TERMINAL ON THE THREE PRONG PLUGS SHOULD NEVER BE REMOVED. THEY ARE SUPPLIED AND DESIGNED FOR YOUR PRO- TECTION. NEVER MAKE ADJUSTMENTS TO ANY ELECTRICAL APPLIANCE OR PRODUCT WITH THE POWER CONNECTED. DO NOT ONLY UNSCREW THE FUSE OR TRIP THE BREAKER, REMOVE THE POWER PLUG FROM THE RECEPTACLE. Material required for drilled well application (indoor use only) 2 Shallow well pump installation Desired length of polyethylene 1 pipe, 100 PSI, CSA or UL approved, to link up from pumping level to pump. 1 1 foot valve (750756 or 750752P). 1 well seal, as per well casing diameter (750929 6 x 1 ). 1 1 well seal elbow (750860). 2 1 male adaptors (750865 or 750871). 8 1 stainless steel clamps (750885). Teflon tape. Tools Screwdrivers, hacksaw to cut pipe, knife to assist in pipe cutting, round file to smooth pipe ends, pipe wrench, adjustable wrench to tighten fittings, propane torch and welding material. VOLTAGE SELECTION SWITCH models since 2006 1. POWER off 2. Please SELECT the up knob position for 115 V or down knob position for 230 V. 3. PUSH plug in to desired voltage. VOLTAGE SELECTION SWITCH 2005 and older 1. POWER off 2. PULL selector plug out 3. ROTATE plug to align arrow to desired voltage 4. PUSH plug in to desired voltage.

APPLICATION This pump is designed for shallow well installation for water level up to 25 feet. Capacity: Suction 506120S 506220S 503120S 503220S 506530SSN 5 715 800 710 754 897 US GPH 10 630 690 622 659 749 US GPH 15 575 625 548 581 638 US GPH 20 500 545 474 502 555 US GPH 25 450 480 437 463 472 US GPH FRICTION LOSS IN PIPE NOT INCLUDED FEATURES Specially treated cast iron pump body or stainless steel. Easy to prime Totally enclosed, fan cooled motor, bearing to bearing. Built for a continuous use. Full time connected run capacitor, to eliminate starting wear vs regular motor. Thermal and overload protection. Noryl impeller, built-in injector 1/2HP, 115VAC, 60Hz, 8A, (16A when start). 3/4HP, 115VAC, 60Hz, 9A, (18A when start). INSTALLATION STEPS STEP 1 We recommend that you install your pump in a clean and dry location where there is adequate room for servicing at a later date. Protection from freezing temperatures and good ventilation should be considered as well, to provide the pump an environment for long life. Locating the pump as close as possible to the water source will reduce friction losses encountered in the suction pipe. Friction losses in the suction pipe must be taken into consideration when the horizontal offset is greater than 50 feet. The suction pipes should be increased from 1 to 1 1/4. This will reduce friction losses and allow the pump to give maximum performance. A new well should be checked to determine that it is free from sand. Sand will damage the seal and the impeller. Have your well driller clean the well before your installation. Never run the pump dry. Damage to the seal may occur. Fill pump body and suction pipe with water before turning on the power. THE RUN OF HORIZONTAL PIPE FROM THE TOP OF YOUR WELL INTO THE HOUSE, WHERE YOUR PUMP WILL BE LOCATED, MUST BE INSTALLED IN A TRENCH, BELOW THE FROST LEVEL OF YOUR AREA. 3

SHALLOW WELL APPLICATION SEE DIAGRAM ON PAGE 5 STEP 2 STEP 3 STEP 4 Cut the desired length of poly pipe to run from the top of the well to the pumping level. Smooth the pipe cuttings with your round file. (Check that no cut-out parts are left inside of pipe. This may block pump injector or impeller). Tape male adaptor threads with teflon tape and thread adaptor into the foot valve. Slide 2 stainless steel clamps over one end of pipe and use torch to soften pipe. Insert the male adaptor and foot valve into this pipe end. Tighten clamps with screwdriver when cool. For security against leaks, we suggest to install 2 stainless steel clamps on each adaptor. Insert the well seal elbow thru the opening of the seal. Slide 2 stainless steel clamps over the free end of the previously cut pipe and soften pipe with your torch. Attach pipe to the well seal elbow (end protruding at bottom of well seal). Tighten clamps with screwdriver when cool. Install the well seal and piping assembly into your well casing. Tight down the well seal bolts using your adjustable wrench. To facilitate servicing at a later date, you may use a pitless adaptor and a sealed well cap instead of an elbow and a well seal as describe in steps 3 and 4. STEP 5 STEP 6 STEP 7 for sand or well points Install your pump in the house, on a sound foundation, as close as possible to the water source. Locate and screw your injector body to your pump body. Locate the suction inlet in the front of the injector. Thread an adaptor into inlet using teflon tape. Do not over tighten. Cut the desired length of pipe from pump location to the well seal and connect both ends using the previous way, with stainless steel clamps and torch. Do not fill in your trench to the house until you have checked for any leaks in your connections or trouble in your water system. Sand or well points are limited to areas where water bearing sand or gravel lies below the surface, and where there are no boulders or rocks to interfere with the driving into the ground of the point. The amount of water any one well point will supply is usually rather limited. Sometimes, it is necessary to use more than one point to increase the supply of water, entering to the pump s suction. THE IMPORTANT INSTALLATION STEP IN USING WELL POINTS IS THAT A CHECK VALVE MUST BE USED IN THE SUCTION PIPE LEADING TO THE SUCTION INLET, AS CLOSE TO THE PUMP AS POSSIBLE, TO KEEP SUCTION LINE AND PUMP WELL PRIMED. STEP 8 Do not use an extension cord to connect your pump to the power source. From your distribution panel to the pressure switch, we recommend a wire gauge not smaller than 14 gauge. 4

SHALLOW WELL APPLICATION STEP 5 Install your pump and thread an adaptor into inlet. STEP 6 Cut poly pipe and connect both ends. STEP 3 Insert well seal elbow thru the seal and attach to pipe. Well point optionnal installation STEP 4 Install well seal and piping into well casing. STEP 7 You may install one or more sand points to increase the supply of water. STEP 2 Cut poly pipe and install the check valve. Check valve, close to pump. 5

REPAIR PARTS REF PARTS DESCRIPTIONS 1 506391 Cast iron pump body 2 750769 Pressure gauge 3 52319 1/4 NPT 1/8 barb brass adaptor 4 506389 Nozzle 5 750748 Plastic tubing 6 506052 Nozzle O-ring 7 506380 Venturi 8 506388 Venturi O-rings (2) 9 506387 Diffuser 10 506055 Impeller brass nut 11 506381 Gasket 12 506056P Noryl impeller 13 506382 Snap Ring 14 506057 Mechanical shaft seal 15 350129 Pump body O-ring 16 506059GP Stainless steel seal plate 17 506060 Sand slinger 18 506062 Body cap screw 19 506061GP Pump bracket 20 506383 Motor flange cap screw 21 506074GP Fan cover REF PARTS DESCRIPTIONS 22 506073GP Motor fan 23 506072GP Motor end bell 24 506385 Wave spring washer 25 350335 Motor bearing fan side 26 506070GP Rotor/shaft 27 506069 Rotor shaft key 28 350335 Motor bearing pump side 29 750957S Pressure switch 30 506075 Motor/pump foot 31 506300 Priming plugs (2) 32 506400 Priming plug washers (2) 33 506067GP2VStator winding 34 506386 Grounding screw 35 506065 Capacitor junction block 36 506094 115/230V selector 37 506064 Motor capacitor 38 506014 Cover box junction 39 506384 Cover box screw 40 506601 Handle for spinkler model 41 52257 Reducer 1 to garden hose. 39 38 41 37 21 34 33 31 32 34 31 36 35 30 27 29 28 1 4 26 2 6 25 7 24 3 23 5 8 22 9 10 11 19 12 20 13 14 18 17 16 15 40 506120S 2007 6 Repair parts may be ordered from your authorized point of sale or from BUR-CAM PUMPS

REPAIR PARTS REF. PART DESCRIPTION 1 506400 Washer 2 506300 Drain and/or priming plug 3 506402 Pump body 4 506051 Nozzle 5 506052 Nozzle O-ring 6 506053 Venturi O-ring 7 506406 Venturi 8 506053 O-ring 9 506317 Diffuser 10 506022 Impeller nut 11 506292P Impeller 12 506411 Snap ring 13 506288 Pump body O-ring 14 506309 Mechanical seal 15 506287 Seal plate 16 506415 Screws (3) 17 506416 Sand slinger 18 506289 Pump bracket 19 506297 Body cap bolts (4) 20 506419 Box cover screw 21 506014OS Junction box cover REF. PART DESCRIPTION 21 506014 Junction box cover 22 506065OS Junction box 22 506065 Junction box 23 506030GP Stator 24 506015 Capacitor 25 506031 Pump side bearing 26 506318 Shaft key impeller 27 506314GP Rotor 28 506032 Fan side bearing 29 506428 Wavy washer 30 506296 Motor end bracket 31 506430 Screws (3) 32 506017 Fan 33 506016 Fan cover 34 506094 115/230V selector (since 2006) 34 506093 115/230V selector (2004-2005) 34 506093IOS115/230V selector (before 2004) 35 506312 Motor/pump foot 36 506601 Handle for spinkler model 37 52257 Reducer 1 NPT to garden hose 38 52212 Brass plug 34 21 20 30 31 32 33 36 37 24 23 35 3 22 26 25 1 27 28 29 8 9 10 4 11 5 12 6 13 7 14 18 15 16 19 17 38 2 506220S 2002 Repair parts may be ordered from your authorized point of sale or from BUR-CAM PUMPS 7

REPAIR PARTS REF. PARTS DESCRIPTION 1 510054 Motor 1/2HP 1 510054-2 Motor 3/4HP 2 510055 Motor screws (4) 3 750957S Pressure switch 4 510056 1/4 NPT 1/4 Barb elbow 5 750748 Hose 6 510053 Seal plate O-ring 7 510052 Mechanical seal 8 510048 Impeller 9 510047 Diffuseur 10 510065 Diffuseur plate REF. PARTS DESCRIPTION 11 510051 Diffuseur plate O-ring 12 510050 Diffuseur plate washers (3) 13 510049 Diffuseur plate screws (3) 14 510069 Venturi 15 510046 Nozzle 16 510056 1/4 NPT 1/4 Barb elbow 17 510045 Cast iron pump body 18 750769 Pressure gauge (not shown) 19 506601 Handle for springkler model 20 52257 Reducer 1 NPT to garden hose 20 19 503120S-503220S 2011 8 Repair parts may be ordered from your authorized point of sale or from BUR-CAM PUMPS

REPAIR PARTS REF. PARTS DESCRIPTION 1 506101 Stainless steel pump body 2 506052S Nozzle O-ring 3 506042S Venturi 4 506053S Venturi O-ring 5 506085 Diffuser 6 506055 Impeller nut 7 506083 Impeller 8 506057 Mechanical seal 9 506084 Pump body O-ring 10 506095 Seal plate 11 506060 Sand slinger 12 506103 Pump bracket 13 506105 Pump body screws (8) 14 506014OS Junction box cover 14 506014 Junction box cover 15 506064 Capacitor 16 506065OS Capacitor junction box 16 506065 Capacitor junction box 17 506097 Stator 18 350335 Bearing pump side 19 506098 Shaft key 20 506099 Rotor shaft 21 350335 Bearing fan side 22 506100 Motor end bell 23 506073GP Motor Fan 24 506074GP Fan cover 25 506104 Motor / pump foot 26 506076 Drain / priming plug 27 506094 115/230V selector 28 506419 Cover screws 33 506601 Handle for sprinkler model (Not shown) 34 52257 Reducer 1 NPT to garden hose REF. PARTS DESCRIPTION 1 510000 Pump body 2 510001 Priming / drainage plug 3 750769 Pressure gauge 4 510003 Pump body screw (6) 5 510004 Venturi O-ring 6 510005 Venturi / diffuser 7 510006 Impeller 8 510007 Washer 9 510008 Mechanical seal 10 510009 Seal plate O-ring 11 510010 Seal plate 12 510011 Water slinger 13 510012 Motor 14 510013 Capacitor 15 510014 Junction box cover 51 510022 Base plate 52 510023 Base plate bolts (2) 53 510024 Base plate washers (4) 54 510025 Base plate nuts (2) 55 510026 Nut 56 510027 Handle 57 510028 Washer 58 510029 Bolt 59 510030 Handle cover 60 510031 Power cable 61 510037 Capacitor holder 27 14 28 15 22 23 24 55 58 57 56 59 16 17 18 21 19 20 4 25 2 26 3 6 7 8 5 12 34 11 10 9 1 2 2 3 4 5 14 10 9 12 13 6 7 8 11 51 15 61 60 54 53 1 13 52 506530SSN 2007 506530SSW Repair parts may be ordered from your authorized point of sale or from BUR-CAM PUMPS

TROUBLE SHOOTING GUIDE CHECKLIST NEVER MAKE ADJUSTMENTS TO ANY ELECTRICAL APPLIANCE OR PRODUCT WITH THE POWER CONNECTED. DON T JUST UNSCREW THE FUSE OR TRIP THE BREAKER, REMOVE THE POWER FROM THE RECEPTACLE. TROUBLE PROBABLE CAUSE ACTION Motor does not run. Switch is off position Blown fuse Tripped breaker Dirty pressure switch Defective pressure switch Defective motor Turn switch to on position Replace Reset Clean Replace Replace Motor runs but no water is delivered. Pump not primed Leaky suction line Foot valve plugged Ejector nozzle clogged Water level below foot valve Suction lift to great Improper voltage Prime with clean water Check pipe and pipe connections Clean Clean Check foot valve level Water level lower than lift capacity Check voltage Pump does not deliver to full capacity. Water level below foot valve Ejector nozzle clogged Excessive friction in pipe Improper voltage Check foot valve level Clean Too small or dirty pipe Check voltage Air spurts from fawcets. Leaky suction line Gaz in water Check pipe and pipe connections Check and consult factory 10 TO THE END CONSUMER If you have any problems with the product, before advising the store, where you ve purchased the pump, please contact us at 514 337-4415, and ask for our sales department, and they will be pleased to help you with any questions you might have, concerning your installation.