www.sylvania.com LEDlescent TM T8 Ballast-Free Lamps
2 North American Market T8 LED Options Replacement Lamps (UL Type A) Internal Driver Line Voltage Lamps (UL Type B) Single Ended Internal Driver Line Voltage Lamps (UL Type B) Double-ended with switch External Driver Lamps (UL Type C) Dual Technology (A&B) SYLVANIA SubstiTUBE Not appropriate design: No SYLVANIA product SYLVANIA LEDlescent TM SYLVANIA HE Kits / SubstiTUBE G8 No SYLVANIA product Advantage: Energy savings; Minimal labor costs for installation, Cost Disadvantage: Ballast compatibility, Higher maintenance costs due to remaining life of existing ballast Advantage: Cost, Energy savings, Low maintenance Disadvantage: Shock hazard; Higher operating temperatures; Nonpassive failure of improperly re-installed traditional lamps Advantage: Easy Installation, Cost, Energy savings, Low maintenance Disadvantage: Small labor for rewiring Advantage: Energy savings; Safe design; Higher LPW capability; Longer life, Low maintenance, System solution Disadvantage: Labor Cost (Initial & Maintenance) Advantage: Uses the current ballast now, can keep working on line voltage later Disadvantage: Single ended: shock hazard, Limited Ballast compatibility
3 LEDlescent T8 Ballast-Free Lamps Ballast free lamps available in 2, 3 and 4 foot options Provide instant light and uniform light distribution. Double ended wiring schematic ensure safe installation Long life: 50,000 hours (L 70 ) Power supply: No ballast needed, installed directly on 120-277V Uses either shunted or un-shunted sockets Versatile option for both T8 and T12 fixtures Warranty: 5-year limited lamp warranty (24/7 operation) Shape Wattage Lumens CCT (K) Applications General lighting Cove Lighting Display Case Parking Garage Tunnels 4ft 17W 2100lm 2200lm 4ft 14W 1700lm 1800lm 3ft 12W 1650lm 2ft 9W 1100lm 3000K/3500K 4100K/5000K
4 LEDlescent T8 Ballast-Free Lamps Features and benefits Double Ended wiring schematic requires line wired to one end and neutral to the other eliminating any shock hazard associated with single ended direct wire tubes. Less expensive to install than single ended. No polarity - can be installed into any fixture in any direction. No Ballast Required - wired directly into 120-277V bypassing the existing ballast that may fail or may not be compatible. Lower cost of ownership than Type A lamps with potential ballast replacement. Flexible - compatible with both shunted and non-shunted sockets, removing the expense of replacing the existing sockets. Replaces medium bi-pin T8 or T12 fluorescent lamps in existing fixtures. Economical Simple Installation in 5 minutes and 20 seconds for a 4-lamp fixture. Reliable Long Life - 50,000 hour expected life; not dependent on the life of an existing ballast like Type A lamps. 4-foot Type B Lamps will meet the DLC rating.
5 LEDlescent T8 Ballast-Free Lamps Wiring Diagram LINE Open until both ends are engaged in the socket; prevents shock NEUTRAL Safety switch technology prevents current across the lamp when only one end is engaged Double Ended - Wire Line to one end, Neutral to the other No polarity: lamp can be installed in either direction Different than other models on the market (single ended, shock hazard) No issues with installing fluorescent lamps back into fixture (no light, burn out coil) Name indicates lamp is different than SubstiTUBE (no ordering mistakes)
6 LEDlescent T8 Ballast-Free Lamps - Installation Installation requires that a caution / warning sticker be applied LED17T8/L48/FG/841/BF Indicates fixture was modified. Informs any person after initial modification that this is no longer suitable to operate fluorescent lamps. Provides information on appropriate lamp for modified fixture
7 LEDlescent T8 Ballast-Free Lamps - Installation Each box of lamps contains an installation guide Contains warnings and cations and details of wiring schematic / diagram for 1-4 lamp scenarios.
8 LEDlescent T8 Ballast-Free Lamps 4ft Product Offering Item Number Ordering Description Lamp Wattage Replaces CCT Lamp Lumens Life Beam Angle DIM DLC 75024 LED17T8/L48/FG/830/BF 17 32W 3000K 2100 50,000 220 No Yes 75025 LED17T8/L48/FG/835/BF 17 32W 3500K 2100 50,000 220 No Yes 75026 LED17T8/L48/FG/841/BF 17 32W 4100K 2200 50,000 220 No Yes 75027 LED17T8L48/FG/850/BF 17 32W 5000K 2200 50,000 220 No Yes 75020 LED14T8L48/FG/830/BF 14 32W 3000K 1700 50,000 220 No Yes 75021 75022 75023 LED14T8L48/FG/835/BF LED14T8L48/FG/841/BF LED14T8L48/FG/850/BF 14 32W 3500K 1700 50,000 220 No Yes 14 32W 4100K 1800 50,000 220 No Yes 14 32W 5000K 1800 50,000 220 No Yes
9 LEDlescent T8 Ballast-Free Lamps 2ft & 3ft Product Offering Item Number Ordering Description Lamp Wattage Replaces CCT Lamp Lumens Life Beam Angle DIM DLC 75009 LED12T8/L36/FG/830/BF 12 32W 3000K 1650 50,000 220 No - 75010 LED12T8/L36/FG/835/BF 12 32W 3500K 1650 50,000 220 No - 75011 LED12T8/L36/FG/841/BF 12 32W 4100K 1650 50,000 220 No - 75012 LED12T8/L36/FG/850/BF 12 32W 5000K 1650 50,000 220 No - 75013 LED9T8/L24/FG/830/BF 9 32W 3000K 1100 50,000 220 No Yes 75014 LED9T8/L24/FG/835/BF 9 32W 3500K 1100 50,000 220 No Yes 75015 LED9T8/L24/FG/830/BF 9 32W 4100K 1100 50,000 220 No Yes 75016 LED9T8/L24/FG/830/BF 9 32W 5000K 1100 50,000 220 No Yes
10 Key TAKE AWAYS Safe solution minimizing risk No ballast compatibility issues Larger Case Size 25 pack
THANK YOU