FUSE LINKS. Catalog 10B October Phone: Web: hubbellpowersystems.com October 2015.

Similar documents
OHIO BRASS AIKEN, SC, USA

Electronic Resettable Sectionalizer

Mechanical Hoists. NOTICE: For latest revision of our Catalog and Literature, please visit our web site:

Fusing Equipment. Kearney Fuse Links. general. Internal Construction. tin element

THE CURVE FOR DOUBLE PROTECTION TRANSFORMER & SYSTEM PROTECTION WITH CHANCE SLOFAST FUSE LINKS

Application of Primary Fuses

Kearney fuse links. Technical Data General. Effective March 2014 Supersedes December 2013

Kearney fuse links. Technical Data General. Effective December 2013 Supersedes November 2009

Hi*Lite XL Suspension Insulators

10DD 10DD-1. Section CAUTION:

Figure 1. Non-removable buttonhead Edison Links. TABLE 1 Edison Link Fuse Designs. System Fuse Ampere Rating Type Rating

Optima Distribution Class (PDV) and Riser Pole (PVR) Surge Arresters

K-SEC 030. Fusing Equipment. Kearney Fuse Links GENERAL INTERNAL CONSTRUCTION SINGLE TIN ELEMENT

COOPER POWER SERIES. K-Limiter back-up current-limiting fuse installation instructions. Fusing Equipment MN132010EN

AD-7. Instruction Manual. Thermal Indicating Ammeter HD ELECTRIC COMPANY 1475 LAKESIDE DRIVE WAUKEGAN, ILLINOIS U.S.A.

WEB CONTROL PRODUCTS

Model NTX7 Series Automatic Battery Charger User s Manual Rev. 1.0 October 17, 2006

Ladders & Platforms. NOTICE: For latest revision of our Catalog and Literature, please visit our web site:

COOPER POWER SERIES. Expulsion fuse installation instructions. Capacitors MN230005EN. Effective November 2016 Supersedes November 2001 (S )

Dimensions 12/800N 12/1200N D. DC to AC Power Inverters. OWNERS MANUAL for Models: OWNERS MANUAL April ISO 9001:2000 Certified Company

Model HPX60 Series Automatic Battery Charger User s Manual Rev. 1.0 October 17, 2006

Installation and Operation

SHAW-BOX INSTRUCTIONS AND PARTS LIST SHAW-BOX RIGID MOUNT I-BEAM AND PATENTED TRACK TROLLEYS (PUSH & HAND GEARED - 1/2 THRU 15 TON RATED LOADS)

Manual Transfer Switch

OWNERS MANUAL JANUARY 2007 ISO

StormPro BA Series Sump Pump

ichards MANUFACTURING COMPANY, SALES, INC. 517 LYONS AVENUE, IRVINGTON, NJ Phone Fax

Installation, Operating & Maintenance Manual 30P Planetary Winch

MIL-24/2600Q MIL-24/3200DQ

II DISTRIBUTION & SUBSTATION TYPE C

Models DP10 & DP20 Series Low Voltage Disconnects User s Manual Rev. 1.1 October 31, 2007

SPC-PANEL Simplex, Single Phase Pump Control Panel

StormPro BCV400 Sewage Ejector Pump

COOPER POWER SERIES. Surge arrester interchangeable fuse cutout combination installation instructions. Surge Arresters MN235004EN

3M Cold Shrink Silicone Rubber Outdoor Termination Kit QT-III 7600-S-3W Series

ADI-125/750 ADI-125/1500 ADI-125/2500

JOHN DEERE 9970 COTTON PICKERS

COOPER POWER. SERIES ELF Current-Limiting Dropout Fuse Installation Instructions. Fusing Equipment MN132028EN. Pull ring. Housing

Replacement of 600-Ampere Bushing and 200-Ampere Bushing-Well Adapters

Female Plug. connecting to Fuel Quantity

Water Jetter Units DU JT50 / DU JT100

RU BMS Power Supply and Battery Management System Owners Guide

80PK-2A Type K Immersion Probe

HE1U 1248 BMS High Efficiency 1U AC to DC Power Supply Owners Guide SPECIFICATIONS

GM Specification Annual Test Data

24/3000H-3PH 24/4500H-3PH 24/6000H-3PH

UniTorq UTQ Quarter-Turn Actuator Installation and Operation Manual

SELECT -24 INSTALLATION GUIDE. INST036 Doc 2.02

3M Cold Shrink Silicone Rubber Termination QT-III 7600-S-3G Series Three-Core Outdoor Termination

SOLUTION DISTRIBUTORS BOOK NO. IM AA UA

Through-Shaft Clutch-Brake LSCB-32HT, LSCB-32HT, LSCB-44, LSCB-44HT, LSCB-54HT FORM NO. L D-0606 MEX (55) QRO (442)

DUSTTRAK AEROSOL MONITOR SOLAR POWER KIT MODEL

Pay For Water System DU 1A046A

60 PSI Boost Gauge. For Product Numbers: MT-DV01_60, MT-WDV01_60

GM Specification Annual Test Data

DC to AC Power Inverters

Presoak & Tire/Engine Cleaner Systems (Air Pump) DU TC_A & DU PS_A

DC to AC Power Inverters

GRINNELL MODEL CB800 CIRCUIT BALANCING VALVE INSTALLATION & SETTING HANDBOOK

3M TM Cubitron TM II Bonded Abrasive Grinding and Cut-Off Wheels. born to. grind. It s grinding reinvented. Featuring. cut & grind wheels

MAINFRAME HOT RUNNER TEMPERATURE CONTROL SYSTEMS. Instruction Manual

37SCENE 46SCENE 79SCENE

MFG. CO. INC. DODGE CITY, KANSAS (620) Electric Truck Auger. Owners Manual

3.2. Current Limiting Fuses. Contents

Straight-Bore Clutch LSCC-32, 44, 54

3M Cold Shrink QT-III Silicone Rubber Three-Core Termination Kits

Do not install and/or operate this safety product unless you have read and understand the safety information contained

Operating Instructions for PAC800 Battery Charger

34-SDMS-02 SPECIFICATIONS FOR

AD-7 THERMAL INDICATING AMMETER

AIR VELOCITY METER ALNOR MODEL AVM410 AIRFLOW INSTRUMENTS MODEL TA410

Model Series. PumpAgents.com - buy pumps and parts online ELECTRIC BILGE PUMPS. Model Series FEATURES SPECIFICATIONS STANDARD MODELS

ASSEMBLY OF TROLLEY TO HOIST

3M Cold Shrink QT-III Silicone Rubber 3/C Cabinet Mount Termination Kit

Do not install and/or operate this safety product unless you have read and understand the safety information contained in this manual.

Cutouts (Standard, Linkbreak & Loadbreak) and Cutout-Arrester Combinations U.S. Patent 4,546,341; 6,392,526

MICROMANOMETER ALNOR MODEL AXD610 AIRFLOW INSTRUMENTS MODEL PVM610

OWNERS MANUAL JANUARY 2007 ISO

Air Curtain. Installation, Operating and Maintenance Instructions

Installation and Operating Manual

Hydraulic Bead Breaker Kit

Utility Controller Hand Air Operated

STAINLESS STEEL FORGED FITTINGS 3000lb 304/304L & 316/316L Forged Stainless Steel Fittings Product Specifications

Power Float Manifold. Installation and Operations Manual Module 11A

Pump Installation and Service Manual HRS Hydromatic Retractable System

DeZURIK 2 20" BOS BUTTERFLY VALVES

IAQ-CALC TM Indoor Air Quality Meter

Saf-T-Bar Conductor Bar T Series

4400-Lb. Cargo Trolley

INSTALLATION AND MAINTENANCE MANUAL FORM #PM-126 REV A 12/09

HR-20P Pneumatically Controlled Pressure Regulator

3MTM CubitronTM II Bonded Abrasive Grinding and Cut-Off Wheels. BORN TO GRIND. IT S GRINDING REINVENTED.

ValveSentry USER S MANUAL PLEASE READ CAREFULLY AND SAVE

Rear Sway Bar for XC90 ( ) 2.5T and T6 ipd mounting kit SBK42

IAQ-CALC INDOOR AIR QUALITY METER MODEL 7515

TONS. Before each shift: Before operating: Before initial operation of hoist:

TOTALIZER-TRANSMITTER

3M AEROSPACE & COMMERCIAL TRANSPORTATION DIVISION St. Paul, MN USA or or Made in USA

Poly Strapping Tensioner & Cutter

Table 1.-Elemsa code and characteristics of Type K fuse links (Fast).

Transcription:

FUSE LINKS Catalog 10B October 2015 Phone: 573-682-5521 Email: hpsliterature@hubbell.com Web: hubbellpowersystems.com October 2015 Page 10B-1

FUSE LINKS Warranty- Material Hubbell Power Systems, Inc. warrants all products sold by it to be merchantable (as such term is defined in the Uniform Commercial Code) and to be free from defects in material and workmanship. Buyer must notify the Company promptly of any claim under this warranty. The Buyer s exclusive remedy for breach of this warranty shall be the repair or replacement, F.O.B. factory, at the Company s option, of any product defective under the warranty which is returned to the Company within one year from the date of shipment. NO OTHER WARRANTY, WHETHER EXPRESS OR ARISING BY OPERATION OF LAW, COURSE OF DEALING, USAGE OF TRADE OR OTHERWISE IMPLIED, SHALL EXIST IN CONNECTION WITH THE COMPANY S PRODUCTS OR ANY SALE OR USE THEREOF. The Company shall in no event be liable for any loss of profits or any consequential or special damages incurred by Buyer. The Company s warranty shall run only to the first Buyer of a product from the Company, from the Company s distributor, or from an original equipment manufacturer reselling the Company s product, and is non-assignable and non-transferable and shall be of no force and effect if asserted by any person other than such first Buyer. This warranty applies only to the use of the product as intended by Seller and does not cover any misapplication or misuse of said product. Warranty - Hubbell Power Systems, Inc. does not warrant the accuracy of and results from product or system performance recommendations resulting from any engineering analysis or study. This applies regardless of whether a charge is made for the recommendation, or if it is provided free of charge. Responsibility for selection of the proper product or application rests solely with the purchaser. In the event of errors or inaccuracies determined to be caused by Hubbell Power Systems, Inc., its liability will be limited to the re-performance of any such analysis or study. s! WARNING These fuse links will not protect personnel from electrocution. Hot gases and high velocity particles are expelled during interruption. This expulsion can cause serious injury. Do not get in line with fuseholder. Stay away from conical space below fuseholder. CAUTION: The equipment covered in this catalog section should be installed, used, and serviced only by competent personnel familiar with and following good work and safety practices. This equipment is for use by such personnel and is not intended as a substitute for adequate training and experience in safe procedures for this type of equipment. This catalog information and any related instruction sheets do not cover all details or situations in equipment use nor do they provide for every possible contingency to be encountered in relation to installation, operation or maintenance. Should additional information and details be desired, or if specific situations arise which are not covered adequately for the user s purpose, the specifics should be referred to Hubbell Power Systems, Inc. 10B-2 October 2015

Fuse Link Types Type K Type QH Type T Type Standard Type MS SloFast Meets All Applicable ANSI/NEMA Standards Chance Type K and Type T fuse links are made in complete accordance with ANSI/NEMA standards. Other Chance links meet all the standards except those covering time-current characteristics. Time-current characteristics for links other than K and T links are not covered in the ANSI standards. Precision - The Standard of Chance Fuse Links Chance fuse links assure system protection because they are precision manufactured. The fusible materials used in Chance Fuse Links are under continual control during manufacture. Pre-tested to guarantee their electrical values, these materials are held to precise tolerances. At critical points during the manufacturing process, rigid inspections are made. Packaging Chance fuse links come in protective plastic bags with perforations to facilitate quick, easy opening even when lineman s gloves are worn. Each bag remains completely sealed for all-weather protection and keeps the links protected in the line truck s bins. Type and amperage is printed on each bag, for easy identification. October 2015 10B-3

Type K Fuse Links The fast characteristics of Type K fuse links were established by ANSI/NEMA to provide fuse links that would meet existing coordination schemes. Chance Type K fuse links are designed to carry 150% of their rated current without damage to the fuse link itself or the cutout in which it is installed. This capacity is for special loading situations, such as shorttime overloads and cold load pick-ups. Fuse Elements The fusible section of the 1 through 3 ampere Type K links consists of a stainless-steel fuse strain wire; the 6 through 10 ampere, stainless-steel strain wire and a copper-alloy fuse wire; 12 through 100 amperes, a stainless steel strain wire and a silver-copper fuse wire; 140 and 200 ampere, a silver-copper fuse wire large enough to serve as both strain and fuse wire. Conforming to all applicable ANSI/NEMA specifications, Chance Type K links are available with a removable or solid buttonhead. Note: s shown are 23 overall length; also available in 26 length. For 26 : *Solid head K or T links, change the last two digits from 23 to 26. Removable head K or T links, drop the last two digits. Twin Pigtail Type K and T Fuse Links The twin pigtail fuse link is convenient to work with and easier to install in the cutout than conventional single pigtail fuse links. The pigtails attach under the clamp with one on each side of the attachment stud. * s shown are 23 in overall length; for 26, see Note above. Type T Fuse Links Chance Type T fuse links provide slower time-current characteristics than the Type K links. Type T links coordinate particularly well with automatic oil-circuit reclosers. Chance Type T links are designed to carry 150% of their rated current without damage to the fuse link itself or the cutout in which it is installed. This capacity is for special loading situations, such as short-time overloads and cold-load pick-ups. Fuse Elements 1 through 3 ampere Type T fuse links employ a fusing section consisting of a stainless-steel wire serving as both strain and fuse wire; 6 through 100 ampere, a stainless-steel strain wire and a pure-tin fuse wire in parallel. 140 and 200 ampere T links have a copper element mechanically crimped at one end, soldered at the other end. On overloads or low faults, the solder becomes a fluid and the link separates; on higher fault currents, the link separates when the copper wire melts. Chance Type T fuse links meet all applicable ANSI/NEMA specifications. They are available with a removable or solid buttonhead. 1 M1K23 M1KA23 2 M2K23 M2KA23 3 M3K23 M3KA23 6 M6K23 M6KA23 8 M8K23 M8KA23 10 M10K23 M10KA23 12 M12K23 M12KA23 15 M15K23 M15KA23 20 M20K23 M20KA23 25 M25K23 M25KA23 30 M30K23 M30KA23 40 M40K23 M40KA23 50 M50K23 M50KA23 65 M65K23 M65KA23 80 M80K23 M80KA23 100 M100K23 M100KA23 140 M140K23 M140KA23 200 M200K23 M200KA23 Type K 200 M200K23T M200KA23T T 200 M200T23T M200TA23T K 140 M140K23T M140KA23T T 140 M140T23T M140TA23T 1 M1T23 M1TA23 2 M2T23 M2TA23 3 M3T23 M3TA23 6 M6T23 M6TA23 8 M8T23 M8TA23 10 M10T23 M10TA23 12 M12T23 M12TA23 15 M15T23 M15TA23 20 M20T23 M20TA23 25 M25T23 M25TA23 30 M30T23 M30TA23 40 M40T23 M40TA23 50 M50T23 M50TA23 65 M65T23 M65TA23 80 M80T23 M80TA23 100 M100T23 M100TA23 140 M140T23 M140TA23 200 M200T23 M200TA23 * s shown are 23 overall length; for 26, see Note above. 10B-4 October 2015

Type MS Fuse Links Chance Type MS fuse links have very slow time-current characteristics. In applications where ANSI/NEMA Type T fuse link characteristics are too-fast, the slower characteristics of Type MS can often be utilized. Fuse-Section Operation The fuse element of Chance Type MS fuse links is composed of two copper or copper-alloy wires joined by a solder junction. During heavy overloads or low fault currents, the heat generated by the two wires melts the solder, causing fuse operation. Operation under medium or heavy fault current occurs as one of the two wires melt. Type MS fuse links are only available with a removable head. Note: s shown are 23 overall length; also available in 26 length. For 26, drop the last two digits. Amps *Removable Head 3 M3MSA23 5 M5MSA23 7 M7MSA23 10 M10MSA23 15 M15MSA23 20 M20MSA23 25 M25MSA23 30 M30MSA23 40 M40MSA23 50 M50MSA23 65 M65MSA23 80 M80MSA23 100 M100MSA23 125 M125MSA23 150 M150MSA23 200 M200MSA23 Type QH Fuse Links The medium speed characteristics of the Type QH fuse links provide good coordination in distribution applications where other fuse links may not be applicable. Fuse Elements The fusible section of the 1 through 7 ampere Type QH links consists of a stainless steel fuse strain wire; the 10 through 100 ampere links consist of a stainless steel strain wire and a silver-copper alloy fuse wire. Chance Type QH links are available with a removable or solid buttonhead. Note: s shown are 23 overall length; also available in 26 length. For 26 Solid or Removable Head, change the last two digits from 23 to 26. Type Standard Fuse Links The speed characteristics of the Type Standard fuse links provide good coordination in distribution applications where other fuse links may not be applicable. Fuse Elements The fusible section of the 1 through 5 ampere Type Standard links consist of a stainless steel fuse strain wire; the 7 through 20 ampere links consist of a stainless steel strain wire and a silver-copper alloy fuse wire; the 25 through 100 ampere links consist of a stainless steel strain wire and a silver alloy fuse wire. Chance Type Standard links are available with a removable or solid buttonhead. Note: s shown are 23 overall length; also available in 26 length. For 26 Solid or Removable Head, change the last two digits from 23 to 26. 1 M1QH23 M1QHA23 2 M2QH23 M2QHA23 3 M3QH23 M3QHA23 5 M5QH23 M5QHA23 7 M7QH23 M7QHA23 10 M10QH23 M10QHA23 15 M15QH23 M15QHA23 20 M20QH23 M20QHA23 25 M25QH23 M25QHA23 30 M30QH23 M30QHA23 40 M40QH23 M40QHA23 50 M50QH23 M50QHA23 60 M60QH23 M60QHA23 75 M75QH23 M75QHA23 100 M100QH23 M100QHA23 1 M1STH23 M1STHA23 2 M2STH23 M2STHA23 3 M3STH23 M3STHA23 5 M5STH23 M5STHA23 7 M7STH23 M7STHA23 10 M10STH23 M10STHA23 15 M15STH23 M15STHA23 20 M20STH23 M20STHA23 25 M25STH23 M25STHA23 30 M30STH23 M30STHA23 40 M40STH23 M40STHA23 50 M50STH23 M50STHA23 65 M65STH23 M65STHA23 80 M80STH23 M80STHA23 100 M100STH23 M100STHA23 October 2015 10B-5

SloFast Fuse Links Transformer Protection Secondary temporary faults that can be withstood by a transformer will not rupture a SloFast fuse link. If secondary faults persist and become dangerous, the SloFast link will operate, preventing damage to the transformer. System Protection When a heavy fault occurs within the transformer primary bushings, a SloFast link clears the transformer from the system before damage can occur, and before any other protective device can operate and cause an unnecessary interruption to any other segment of the system. Heater coil Heat absorber Solder junction Fuse wire Strain wire Insulated strain pin Slow section Fast section 1000 Construction and Theory of Operation The inner construction of the SloFast Fuse Link is illustrated in the cutaway view above. There are two distinct current-responsive elements: one slow, one fast. The slow current-responsive element is made up of a number of components. The heater coil and the soldered junction are the two primary components. The insulated strain pin serves to carry the tension exerted when the fuse link is installed in a fuse cutout, and as a heat conductor to the soldered junction. The ceramic tube serves as a heat absorber. The slow current-responsive element functions in the following manner: The heater coil generates heat at a rate which is proportional to the square of the current. This heat is absorbed by the ceramic material and transmitted to the soldered junction via the metallic strain pin. When a certain value of current flows for a specific length of time, sufficient heat is generated and transmitted to the soldered junction to cause melting of the solder, separation of the fuse link, and interruption of the circuit. The time-current curve of the slow current-responsive element is the portion above the knee (4 seconds to 5 minutes on the time axis) in the graph on the right. The fast current-responsive element is constructed like the single element in a conventional fuse link. Operation of the fuse link in time periods of less than 4 seconds is conventional. The time-current curve of the fast current-responsive element is the portion below the knee in the time-current graph on the right. Data A comparison of the time-current curves of the Chance SloFast fuse link with those of conventional fuse links and the safe-loading time current characteristics for distribution transformers illustrates the application potential of the SloFast fuse links. The rather unusual current rating assigned to SloFast fuse links is an aid in their application since the current rating assigned is identical to the continuous current rating of the transformers which they were specifically designed to protect. If the SloFast link is used in place of ordinary links, the full overload capacity of the transformer is made available, but at the same time the transformer is protected from faults and overloads which could either destroy or shorten its life expectancy. SloFast is the perfect match for transformer protection. Note: For application of SloFast links for transformers, see Bulletin 10-8010. Note: s shown are 23 overall length; also available in 26 length. For 26 links, drop the last two digits. Time (Seconds) 100 10 1 1 10 100 Current (Amperes) Safe Loading Curve NEMA 3 Amp K NEMA 8 Amp K NEMA 25 Amp K Chance 3.5 Amp SloFast 0.4 M0D4SF23 M0D4SFA23 0.6 M0D6SF23 M0D6SFA23 0.7 M0D7SF23 M0D7SFA23 1.0 M1D0SF23 M1D0SFA23 1.3 M1D3SF23 M1D3SFA23 1.4 M1D4SF23 M1D4SFA23 1.6 M1D6SF23 M1D6SFA23 2.1 M2D1SF23 M2D1SFA23 3.1 M3D1SF23 M3D1SFA23 3.5 M3D5SF23 M3D5SFA23 4.2 M4D2SF23 M4D2SFA23 5.2 M5D2SF23 M5D2SFA23 6.3 M6D3SF23 M6D3SFA23 7.0 M7D0SF23 M7D0SFA23 7.8 M7D8SF23 M7D8SFA23 10.4 M10D4SF23 M10D4SFA23 14 M14SF23 M14SFA23 21 M21SF23 M21SFA23 32 M32SF23 M32SFA23 46 M46SF23 M46SFA23 10B-6 October 2015

NOTES October 2015 10B-7

8100 Churchill Avenue Leeds, Alabama 35094 (205) 699-0840 NOTICE: For the latest revision of our Catalog and Literature, click here or visit our web site: www.hubbellpowersystems.com NOTE: Hubbell has a policy of continuous product improvement. Please visit hubbellpowersystems.com to confirm current design specifications. Copyright 2015 Hubbell Incorporated NEVER COMPROMISE www.hubbellpowersystems.com CA_11_015_E October 2015