G3 LOW PROFILE AIRPOT BREWER

Similar documents
G3 GEMINI INTELLIFRESH BREWER

CURTIS D60GT12A000 TROUBLESHOOTING GUIDE. Service & Sales

THERMOPRO BREWERS TROUBLESHOOTING GUIDE MODELS: TP15T10A1100, TP15S10A1500. Service & Sales

G3 PRIMO CAPPUCCINO SYSTEMS

GEMINI 200R 12 & 24 CUP COFFEE BREWER SERVICE MANUAL. Wilbur. Co., Inc. Montebello, California Tel: 800/ Fax: 323/

Item Part No Description Item Part No Description Screw, 6-32 X 3/8" Column, LD * Wrapper, Models LP, S Washer, #8

Unit 5 Troubleshooting

COMPONENT ACCESS. If no voltage is present, check wiring to the board. If voltage is present, and brewer does not power on, replace board.

ETP-5E & ETP-10E ECO-TECH PLUS ELECTRIC CONVECTION STEAMER PARTS AND SERVICE MANUAL

BIGLA30-T/BIELA14-T Event Codes Quick Reference EXPLANATION CORRECTIVE ACTION PARTS TO CARRY ON SERVICE CALL

Unit 5 Troubleshooting

SPARE PARTS CATALOG TC LD AP TD S LP IA SERIES BREWERS

! WARNING To avoid risk of electrical shock, personal injury or death; disconnect power to oven before servicing, unless testing requires power.

30A SMART ENERGY MANAGEMENT SYSTEM TM

Circuit Board Diagnostics

PAGE Both power cords must be connected & powered to operate the E-TES 120.

ETP-5G & ETP-10G ECO-TECH PLUS GAS CONVECTION STEAMER PARTS AND SERVICE MANUAL

DRINK SINGLE CUP BREWER

Reproduction or other use of this Manual, without the express written consent of Vulcan, is prohibited.

Application Engineering

SERVICE MANUAL IMPINGER COUNTERTOP OVEN MODEL 1300 SERIES

INOVA HIGHTECH Ltd. MEP 002/003 Auto Starter Manual

Spare Parts Catalog. ACE Series Automatic Coffee Brewer: Glass Decanter, Thermal Carafe, Thermal Dispenser, & Thermal Airpot ACE-LP ACE-TC ACE-TD

MICRO P-711 Exerciser Instruction Book

USERS GUIDE LO-21U LOCKOUT RELAY

Troubleshooting Manual

DRINK SINGLE CUP BREWER

PARTS & SERVICE MANUAL

CLOUDBOX Quick Start Guide

Horizon Troubleshooting Flowchart

HP21 SERVICE SUPPLEMENT UNIT INFORMATION. TSC6 Two-Speed Control

Installation Instructions

Installation Instructions

Parking Brake Indicator Is Flashing

ELECTRIC FENCE ENERGIZER SERVICE MANUAL MODEL 950 SERVICE MANUAL FOR OLLI 950 FENCE ENERGIZERS

DTC P0128: THERMOSTAT RATIONALITY

Sprayhead. 5-hole - S/S A,I Gasket, Sprayhead A,I

PAGE Both power cords must be connected & powered to operate the E-TES SD 120 volt unit.

POWERTRAIN CONTROL MODULE (PCM) - NGC

SERVICE MANUAL (DOMESTIC & INTERNATIONAL)

INSTALLATION INSTRUCTIONS

POWERLINE 2000 Energy Management System TM

f i r e - p a r t s. c o m

DRIVE STARTUP MANUAL. Magnetek HPV900-S2 Drive. PM Motor Installation

INSTALLATION & OPERATING INSTRUCTIONS

Explanation 1 Input External Switch 2 Input Hipot Safety Switch

TS-E TURBO STEAM ELECTRIC COUNTERTOP CONVECTION STEAMER PARTS AND SERVICE MANUAL

Troubleshooting Guide

SYMBOL LEGEND DANGER WARNING NOTE THIS INDICATES DANGER TO THE LIFE AND HEALTH OF THE USER IS APPROPRIATE PRECAUTIONS ARE NOT TAKEN

! WARNING To avoid risk of electrical shock, personal injury or death; disconnect power to oven before servicing, unless testing requires power.

Solstice Electric Fryers SE Series Service Manual

FC-S3 FC-5 FC-3 FC-TD FC-AP FC-LD FC-S

DIAGNOSTIC TROUBLESHOOTING INDEX

! WARNING To avoid risk of electrical shock, personal injury or death; disconnect power to oven before servicing, unless testing requires power.

This document describes the commissioning checklist procedures for the Capstone MicroTurbine systems.

OnCommand Troubleshooting Guide Hayward Industries

! WARNING To avoid risk of electrical shock, personal injury, or death, disconnect power to range before servicing, unless testing requires power.

SPARE PARTS CATALOG TC LD AP TD S LP ACE SERIES BREWERS

refrigeration SHAKE #15-77CMT ICE CREAM MACHINE ELECTRO FREEZE 21 SHAKE DISPENSE HEAD ASSEMBLY SHAKE BEATER SEAL ASSEMBLY 9

TECHNICAL SERVICE DEPARTMENT Technical Service Bulletin LowNOx Commercial Gas Electronic Spark Ignition Sequence

KEY PART # DESCRIPTION KEY PART # DESCRIPTION

! WARNING To avoid risk of electrical shock, personal injury or death; disconnect power to range before servicing, unless testing requires power.

ITCB ITCB-DV Infusion Series

Chrysler Electronic Ignition System

MODULE TEST UNIT. Part No: MTU-12 V2.1

Application Engineering

Error code explanation Diagnostics...2 Error Code Chart...3 Tests Wiring diagram...6

Overview Spare Parts Manual Update: 3/11/04

Installation Instructions

Technical Information and Diagnostic Guide RestStar Use this guide with 5700XE RestStar Unit. Western Star 5700XE.

SYMPTOM POSSIBLE CAUSES CORRECTIVE ACTION

ASSEMBLY INSTRUCTIONS ZONE MODULE 2 1 THERMOSTAT DESCRIPTION POWER SUPPLY AIRZONE CONTROLLER

12V PROGRAMMABLE POWER OUT

! WARNING To avoid risk of electrical shock, personal injury or death; disconnect power to oven before servicing, unless testing requires power.

Troubleshooting Electronic Ignition

PARTS AND SERVICE MANUAL FOR MERCO HOLDING CABINET MODEL MHC-22-TDL

DISCONTINUED VERSION Parts listed in this catalog may no longer be available. ILLUSTRATED PARTS CATALOG BUNN-O-MATIC CORPORATION

DISCONTINUED VERSION Parts listed in this catalog may no longer be available. ILLUSTRATED PARTS CATALOG

24-00 ELECTRICAL POWER

50 AMP Smart Energy Management System Model 800 SERVICE MANUAL 50 AMP SMART EMS. 50 Amp EMS Display Panel P/N A I N A I N

Portable Generator Familiarization & Troubleshooting Guide Section 3 Generator Diagnostics and Adjustments

SECOND GENERATION Use this guide with unit serial number prefix beginning with BWF using Terra Power separator.

Fuel Pump Electrical Circuit Diagnosis

Introduction. System Components

R & D SPECIALTIES ROTROL I USER'S MANUAL

INSTALLATION/OPERATING INSTRUCTIONS TSC

Service Manual W365H, W375H, W3105H, W3130H, W3180H, W3240H, W3300H Exacta

SINGLE TF DBC W/SMART FUNNEL

CATALOG OF REPLACEMENT PARTS ER SERIES FRYER

Electronic Service Manuals

DP140e. Installation & Operations Manual

MODEL CMA-44 PARTS MANUAL Rev 2.13

SST-3 Start-Stop-Throttle

CIVACON GROUND VERIFICATION RACK MONITOR SYSTEM and ASSOCIATED EQUIPMENT

BRAVO Inverter/Battery Charger. Table of Contents

Trouble Shooting a Jouan C/CR4.22 Centrifuge

DISCONTINUED VERSION Parts listed in this catalog may no longer be available. ILLUSTRATED PARTS CATALOG

PureSine 150/300 Pure Sine Wave Inverter User s Manual

XR8 SERIES GAS & ELECTRIC ROTATING RACK CONVECTION OVENS REPLACEMENT PARTS LIST

BLOWER VACUUM SWITCH FAILED OPEN

Transcription:

G3 LOW PROFILE AIRPOT BREWER TROUBLESHOOTING GUIDE TLP

BREWER PARTS IDENTIFICATION PART # DESCRIPTION 1. WC-2962-101K KIT, FITTING SPRAYHEAD KYNAR 2. WC-717 CONTROL BOARD, SMART CARD SWITCH PANEL 3. WC-29030 SPRAYHEAD ASSY, ADVANCED FLOW ORANGE 4. WC-715 CONTROL MODULE, TLP 120V 16PIN 5. WC-102 SWITCH, TOGGLE SPST 25A 250VAC RESISTIVE 6. WC-1040 PUMP, WATER CENTRIFUGAL 120V 60 Hz 7. WC-1809 FAUCET, PS/HPS SERIES HOT WATER 1/2-20 UNF AP/ALP 8. WC-826L VALVE INLET 1GPM 120V 10W PART # DESCRIPTION 9. WC-5310 TUBE, 5/16 ID x 1/8W SILICONE 10. WC-43062 GASKET, TANK 11. WC-5502-01 KIT, PROBE, ASSY WATER LEVEL W/HEX FITTING, O-RING & NUT 12. WC-917-04 ELEMENT, HEATING 1.45KW 120V W/JAM NUTS & SILICONE WASHER 13. WC-523 THERMOSTAT, MANUAL RESET 120/220 VAC 25A 220 DEG F MAX 14. WC-1438-101 SENSOR, HEATING TANK 15. WC-1806 SEAT CUP, SILICONE

PARTS IMAGES 1 2 3 WC-2962-101K KIT, FITTING SPRAYHEAD KYNAR WC-717 CONTROL BOARD WC-29030 SPRAYHEAD ASSY, ORANGE 4 5 6 WC-715 CONTROL MODULE WC-102 TOGGLE SWITCH WC-1040 WATER PUMP 7 8 9 WC-1809 FAUCET, HOT WATER WC-826L VALVE INLET WC-5310 SILICONE TUBE 10 11 12 WC-43062 GASKET, TANK WC-5502-01 KIT, PROBE, O-RING & NUT WC-917-04 ELEMENT, HEATING 13 14 15 WC-523 THERMOSTAT, MANUAL WC-1438-101 SENSOR, HEATING TANK WC-1806 SEAT CUP, SILICONE

TROUBLESHOOTING INSTRUCTIONS POWER ISSUES The unit will not turn on: STEP 1. Verify that the panel breaker is turned on. STEP 2. Verify voltage at the receptacle reads: (L1-N = 120v, N-G = 0v). STEP 3. Verify that the power cord is properly connected to the receptacle. STEP 4. Verify that the toggle switch is in the ON position. STEP 5. Verify the voltage at the reset thermostat, it should read 120v between each terminal + neutral. STEP 6. Verify the voltage at the toggle switch, it should read: 120v between each terminal + neutral. STEP 7. Verify that there is 120v between pins #15 & #16 on the Molex connector at UPM. STEP 8. If all steps were taken and unit doesn t turn on, verify 5 VDC between pins #1 & #2 on 4 pin connector on SPS module: Yes: Replace SPS module. No: Replace UPM. HEATING ISSUES Not heating: STEP 1. Verify 120 volts across the manual reset thermostat. Yes: Proceed to STEP 2. No: Reset or replace the manual reset thermostat. STEP 2. Verify 120 volts across the toggle switch. Yes: Proceed to STEP 3. No: Replace the toggle switch. STEP 3. Verify 120 volts across the Heating Element. Yes: Replace the heating element. No: Replace the UPM. Overheating/Steaming: Ready to Brew OFF STEP 1. Verify that the resistance on the temperature sensor is less than 10k ohm with a hot tank (200+ degrees). Yes: Bypass the sensor using a jumper with a 5k ohm resistor. No: Verify correct mounting and that the walls of the tank are free of mineral deposits. If the unit stops heating, replace the temperature sensor. No: Replace the UPM. Ready to Brew ON Check for continuity between C & N O on UPM (Heating Relay). If continuity is present, replace UPM.

TROUBLESHOOTING INSTRUCTIONS - continued TANK FILLING ISSUES Not filling: Ready to Brew light flashes 3+1 (Water Level Error Code) STEP 1. Verify the flow rate to be a minimum of 1 GPM from outlet of the water filter. If not, ensure that the inlet side of the water filter is receiving a minimum of 1 GPM. Yes: Replace the water filter. If not, consult a plumber. No: Remove the orange wire from the probe. STEP 2. Does the tank start filling? Yes: Replace the water level probe. Overfilling: Turn OFF toggle switch. STEP 1. Does the tank continue to fill? Yes: Replace water inlet valve. No: Ground the probe wire to the chassis. STEP 2. Does the tank continue to fill? Yes: Replace the UPM No: Replace the water level probe. No: Verify 120 volts across the inlet valve coil. STEP 3. Was 120 volts verified? Yes: Replace inlet valve. No: Replace UPM. BREWING ISSUES Ready to Brew is Flashing But... No response when Brew Button is pressed. Replace the SPS Module. No water flow from the sprayhead: STEP 1. Does water flow from the hot water faucet? Yes: Verify 120 volts at the pump. If voltage is present at the pump, replace the pump. No: If 120 volts is not present at the pump, confirm continuity of wiring between Molex connector and pump. If OK, replace the UPM. No: If water does not flow from the hot water faucet, replace the water level probe. Short Pots: STEP 1. Verify that the hot water tank is filling correctly. (See Tank Filling Issues) BEFORE REPLACING ANY PARTS, VERIFY THE FOLLOWING: Ensure correct alignment of the sprayhead fitting and that the tubing is routed properly to allow for maximum water flow. Overflowing: STEP1. Ensure that the sprayhead (Orange AFS ONLY) has not been removed. Replace as needed. STEP 2. Ensure that the Hot Water Tank is not overflowing (See Tank Filling Issues) STEP 3. Ensure Cold Brew Lock is set to 5 F.

NOTES

Wilbur Curtis Co., Inc. 6913 Acco Street, Montebello CA 90640 Customer Service: 800.421.6150 323.837.2300 csrassistance@wilburcurtis.com Tech Support: 800.995.0417 JUN/2017 M275_TS_WC_TLP_revNC