Level instruments. Continuous level measurement - Capacitance transmitters SITRANS LC300. 5/262 Siemens FI Overview.

Similar documents
Level Measurement. Continuous level measurement - Capacitance transmitters SITRANS LC500. 5/282 Siemens FI Overview.

Continuous level measurement Capacitance transmitters

Point level measurement Capacitance switches

Level Measurement Point level measurement - RF Capacitance switches

Level Measurement. Point level measurement Capacitance switches. Pointek CLS300 Standard. 5/42 Siemens FI Overview.

Level Measurement. Point level measurement Capacitance switches. Pointek CLS200 Standard. 4/18 Siemens FI Overview.

Level Measurement Continuous level measurement - Capacitance transmitters

Level Measurement. Point level measurement Capacitance switches. Pointek CLS200 Standard. icenta Controls Ltd

Level Measurement Point level measurement - RF Capacitance switches

Level Measurement Point level measurement - RF Capacitance switches

Level Measurement. Point level measurement Capacitance switches. Pointek CLS200 Standard. 5/16 Siemens FI Overview.

Level Measurement Continuous level measurement Ultrasonic transmitters

Level instruments. Point level measurement - Vibrating switches SITRANS LVL100. 5/78 Siemens FI Horizontal mounting.

Flow Measurement SITRANS F C

Level Measurement Continuous level measurement - Radar transmitters

Motion sensors. Milltronics MFA 4p 6/17. Overview

SITRANS L Level instruments

Level limit switch Series RF 3000 Selection list

SITRANS P measuring instruments for pressure

Process Protection Motion sensors

Flow Measurement SITRANS F C. Flow sensor MASS 2100 DI 3 to DI 40. 4/180 Siemens FI

Actuators & Positioners Electro-Pneumatic Converters I/P Signal Converters - TEIP 11 Model without Booster Stage

Level Measurement Continuous level measurement Radar transmitters

Level Probes multicap T DC 12 TE multicap T DC 11/16/21/26 TEN/TES

SITRANS F flowmeters SITRANS F US. SITRANS FUT1010 Ultrasonic flowmeter. Overview. Application

SITRANS T measuring instruments for temperature

Level Measurement Point level measurement - Vibrating switches

Flow Measurement SITRANS F M. Flow sensor MAG /85. Overview

SITRANS F M. Flow sensor MAG 1100 F 3/59

Process Protection Motion sensors

Magnetic float switch For vertical installation Model FLS (models with Ex approval: 60, AL-ADF)

DMK 331P. Industrial Pressure Transmitter. Pressure Ports With Flush Welded Stainless Steel Diaphragm

Field IT Actuators & Positioners Electro-Pneumatic Converters I/P Signal Converters Standard Model with Booster Stage

SITRANS P measuring instruments for pressure

A Higher Level of Performance. Data Sheet. Centurion. Guided Radar. CGR Series. For more information, please visit >

Flow Measurement SITRANS F M

DMK 331P DMK 331P. Industrial Pressure Transmitter. Pressure Ports With Flush Welded Stainless Steel Diaphragm. Pressure Transmitter.

DMK 331P. Industrial Pressure Transmitter. Pressure Ports With Flush Welded Stainless Steel Diaphragm. accuracy according to IEC 60770: 0.

Flow Measurement SITRANS F M. Flow sensor MAG 1100 F 4/57

DMP 331P DMP 331P. Industrial Pressure Transmitter. Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm

Series Level-Trol Electronic Liquid Level Transmitters

Temperature Measurement Resistance thermometers

JUMO dtrans p20. Process pressure transmitter. Type Brief description. Key features. Block diagram

System 6000 Electropneumatic Converter for Direct Current Signals Type 6116 i/p Converter

Process Protection. 7/2 Product overview. 7/3 Acoustic and motion sensing. Acoustic sensor for pump monitoring 7/5 SITRANS DA400

A Higher Level of Performance. Data Sheet. Centurion. Guided Radar. CGR Series. For more information, please visit >

Mobrey MLT100. Displacer Level Transmitter. Product Data Sheet February 2015 IP119, Rev CA. Level, contents or interface measurement transmitter

DMP 331P. Industrial Pressure Transmitter. Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm

XMP ci. Process Pressure Transmitter with HART -communication. Ceramic Sensor. accuracy according to IEC 60770: 0.1 % FSO.

Process Protection Motion sensors

Level Probes multicap T DC 12 TA multicap T DC 11/16/21/26 TAN/TAS

VersaFlow Vortex 100 Vortex Flow Meter Specifications

Micro Motion F-Series Coriolis Flow and Density Meters

Belt Scales Speed sensors

SITRANS F X SITRANS FX300 3/355

BGN. All Metal Variable Area Flow Meter. Technical Data Sheet

SITRANS FC. Flowmeter SITRANS FC410

V200 Series Positioners

SATRON VDt Differential Pressure Transmitter

Metal tube variable area flowmeter for gases, liquids and steam

V200 Series Positioners

Belt Scales Speed sensors

DMP 331 DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor. Pressure Transmitter. Industrial

SITRANS FX300 4/289. System Overview. Overview

TZIM. Electropneumatic Analog Positioner 10/ EN

Level Probes multicap DC 11/16/21/26 EN multicap DC 11/16/21/26 ES

LMK 387. Stainless Steel Probe. Ceramic Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % FSO

Level Measurement Point level measurement - Vibrating switches

Level Limit Switch soliphant II FTM 30 (D/S), FTM 31 (D/S), FTM 32 (D/S)

V200 Series Positioners

Magnetic Float Switches horizontal 1003-h

DMP 333. Industrial Pressure Transmitter For High Pressure. Stainless Steel Sensor

VALVE ACCESSORIES & CONTROLS V200 POSITIONER A POSITIONER THAT OFFERS IT ALL IN ONE COMPACT, SIMPLE, HOUSING

SATRON VT Pressure Transmitter

INLINE Flow sensor for hazardous area II 1 G/D - II 2 D - II 3 GD - I M1

Belt Weighing. Milltronics Belt Scales. Introduction. 4/2 Siemens WT

DPT 200. Differential Pressure Transmitter for Process Industry with HART -Communication. accuracy according to IEC 60770: 0.

Micro Motion T-Series Straight-Tube Mass Flow and Density Meters. Product Data Sheet PS July 2001

Level Limit Switch liquiphant FTL 365 / FTL 366

SITRANS F C. Flow sensor MC2 4/193. Overview

DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor

Threaded resistance thermometer Model TR10-C, with fabricated thermowell model TW35

ABB Instrumentation. 50T Series Transmitters Model 54G/A gauge/absolute pressure transmitter for sanitary use. Specification sheet

Belt Scales Milltronics Belt Scales

Soliphant II FTM30(D/S)/31(D/S)/32(D/S)

JUMO dtrans p20. Process pressure transmitter. Brief description. Special features. Block diagram. Approvals/approval marks (see "Technical data")

Flow Measurement SITRANS F M

Flow Measurement SITRANS F C

Product presentation SITRANS P310

Rosemount 3051CFA Annubar Flowmeter

OPTISWITCH 4000/5000. Vibration level switches for liquids

Series 3730 Electropneumatic Positioner Type

ORIMAS Mass Flowmeter

Level Probe multicap DC 16

STEEMCO-MAS Flowmeter for Steam

Pressure transmitter PASCAL CV4

Rosemount Product Data Sheet , Rev GA Catalog FIELDBUS PROTOCOL. Hazardous Locations Certifications

Compact pressure switch Model PCS

ETP80. Electronic Transmitter for Pressure, Differential Pressure and Level

Rosemount 3051S Electronic Remote Sensor (ERS) System

Transcription:

Overview Configuration is an inverse frequency shift capacitance continuous It is ideal for standard industrial applications in chemical, hydrocarbon processing, food and beverage and mining, aggregate and cement industries. Benefits Patented Active-Shield technology so measurement is unaffected by material buildup in active shield section Highly accurate and reliable PFA-lined probes Integrated local LCD display 2-wire (4 to 20 ma) current loop design Current signalling according to NAMUR NE 43 Push-button calibration and programming installation Application is a 2-wire level measurement instrument combining a sophisticated, yet easy-to-adjust microprocessor with field-proven probes. It is available in two versions: rod and cable. has a process connection with PFA-lined probe. Materials with low or high dielectric properties are accurately measured and patented Active-Shield technology helps in ignoring the effects of buildup near vessel nozzle. Key Applications: Conductive and non-conductive media including liquids and solids in standard industrial processes and bulk solids applications involving dust or chemical processes involving vapour /262 Siemens FI 01 2010

Level instruments Technical specifications Input Measuring range Span Output Loop current Accuracy (transmitter) Temperature stability Non-linearity and repeatability Accuracy 1.66 to 3300 pf Min. 3.3 pf Continuous signal 4 to 20 ma/20 to 4 ma according to NAMUR 43 0.2% of actual capacitance value < 0.4% of full scale and actual measurement value Deviation < 0.% of actual measurement value Rated operating conditions 1) Ambient conditions Ambient temperature -40 to +8 C (-40 to +18 F) 2) Installation category II Pollution degree 4 Ingress protection Type 4/NEMA 4/IP6 (optional IP68) Installation conditions Location Indoor/outdoor Process pressure -1 to 3 bar g (-14.6 to 11 psi g) Process temperature -40 to +200 ºC (-40 to +392 ºF) Min. dielectric constant ε r 1. Design Material Enclosure Aluminum, epoxy-coated Probe diameter Rod version 19 mm (0.7") with PFA jacket Cable version 9 mm (0.3") with PFA jacket, 6 mm (0.24") without PFA jacket Active shield length Rod version 100 mm (3.94") Cable version 10 mm (4.13") Process connection of probe Threaded rod mounting ¾",1",1¼", 1½" NPT [(Taper), ANSI/ASME B1.20.1] R ¾",1",1¼", 1½" [(BSPT), EN 10226/PT (JIS-T), JIS B 0203] G ¾",1", 1½" [(BSPP), EN ISO 228-1/PF (JIS-P), JIS B 0202] Threaded cable mounting 1½" NPT [(Taper), ANSI/ASME B1.20.1] R 1½" [(BSPT), EN 10226/PT (JIS-T), JIS B 0203] G 1½" [(BSPP), EN ISO 228-1/PF (JIS-P), JIS B 0202] Flange mounting 1 to 4" ASME, DIN DN 2 to 100 Enclosure cable inlet 2 x ½" NPT or 2 x M20x1. Power supply 12 to 30 V DC any polarity, 2-wire current loop circuit User Interface Display Local LCD, 4 digit, each 0 to 9 and limited alpha characters Safety Measurement current signalling According to NAMUR NE 43, signal 3.8 to 20. ma, fault 3.6 or 21 ma (22 ma) Certificates and approvals General CE, CSA, FM, C-TICK Dust Ignition Proof (Intrinsically Safe probe circuit) Explosion Proof (Intrinsically Safe probe circuit) Marine CSA/FM Class II, III, Div 1, Groups E, F, G T4 ATEX II 1/2 D T100 C CSA/FM Class I, Div 1, Groups A, B, C, D T4 ATEX II 1/2 G EEx d [ia] IIC T6 to T1 Bureau Veritas, American Bureau of Shipping (ABS) 1) When operation is in areas classified as hazardous, observe restrictions according to relevant certificate. See also Pressure/Temperature curves on page /268. 2) Thermal isolator is used if process connection temperature exceeds +8 C (+18 F) Design: Probe Standard version Cable version Length Min. 300 mm (12"), max. 000 mm (197") Min. 1000 mm (40"), max. 2000 mm (984") Sensor wetted parts PFA, 316L stainless steel 316, optional PFA O-ring seal material 1) FKM FKM Thermal isolator Optional Optional 1) FFKM available as special option. Contact nacc.smpi@siemens.com for details. Siemens FI 01 2010 /263

, threaded 7 M L 6 2 - An inverse frequency shift capacitance continuous 7 7 7 77-77 A 7 Version (threaded lengths include process thread) Rod, 19 mm (0.7") diameter, 300 to 1000 mm (11.81 to 39.37") 0 A 1001 to 2000 mm (39.41 to 78.74") 1 A 2001 to 3000 mm (78.78 to 118.11") 1) 2 A 3001 to 4000 mm (118.1 to 17.48") 1) 3 A 4001 to 000 mm (17.2 to 196.8") 1) 4 A Rod, 19 mm (0.7") diameter, with 3 mm (1.38") diameter stilling well 300 to 1000 mm (11.81 to 39.37") 2) 0 B 1001 to 2000 mm (39.41 to 78.74") 2) 1 B 2001 to 3000 mm (78.78 to 118.11") 1) 2) 2 B 1) 2) 3001 to 4000 mm (118.1 to 17.48") 3 B 1) 2) 4001 to 000 mm (17.2 to 196.8") 4 B Cable, 9 mm (0.7") diameter,, weighted 1000 to 2000 mm (39.37 to 78.74") 2) 0 E 2001 to 4000 mm (78.78 to 17.48") 2) 1 E 4001 to 6000 mm (17.2 to 236.22") 2) 2 E 6001 to 8000 mm (236.26 to 314.96") 2) 3 E 8001 to 10000 mm (31 to 393.70") 2) 4 E Cable, 6 mm (0.24") diameter, non-insulated, weighted (non-conductive media only) 1000 to 2000 mm (39.37 to 78.74") 2) 0 F 2001 to 4000 mm (78.78 to 17.48") 2) 1 F 4001 to 6000 mm (17.2 to 236.22") 2) 2 F 6001 to 8000 mm (236.26 to 314.96") 2) 3 F 8001 to 10000 mm (31 to 393.70") 2) 4 F Cable lengths up to 2000 mm (984.2") are possible for non-conductive media. Cablelengths up to 1000 mm (90.") are possible for conductive media. Contact nacc.smpi@siemens.com for details. Process connection ¾" NPT [(Taper), ANSI/ASME B1.20.1] 3) A 0 1" NPT [(Taper), ANSI/ASME B1.20.1] 3) B 0 1½" NPT [(Taper), ANSI/ASME B1.20.1] C 0 R ¾" [(BSPT), EN 10226/PT (JIS-T), JIS B 0203] 3) D 0 R 1" [(BSPT), EN 10226/PT (JIS-T), JIS B 0203] 3) E 0 R 1½" [(BSPT), EN 10226/PT (JIS-T), JIS B 0203] F 0 1¼" NPT [(Taper), ANSI/ASME B1.20.1] K 0 G ¾" [(BSPP), EN ISO 228-1/PF (JIS-P), L 0 JIS B 0202] 3) G 1" [(BSPP), EN ISO 228-1/PF (JIS-P), M 0 JIS B 0202] 3) G 1½" [(BSPP), EN ISO 228-1/PF (JIS-P), N 0 JIS B 0202] Approvals General purpose: CE, CSA, FM, C-TICK 1 CSA and FM Class II and III, Div. 1, Groups E, F, G 2 T4; ATEX II 1/2 D T100 C ATEX II 1/2 G EEx d [ia] IIC T6 to T1 3 CSA/FM Class I, Div. 1, Groups A, B, C, D T4 4, threaded 7 M L 6 2 - An inverse frequency shift capacitance continuous 7 7 7 77-77 A 7 Enclosure Aluminum, epoxy-coated Cable entry 2 x ½" NPT, IP6 0 Cable entry 2 x M20x1., IP6 1 Cable entry 2 x ½" NPT, IP68 2 Cable entry 2 x M20x1., IP68 3 Thermal isolator 4) None A With thermal isolator B With mounting eye ) C With thermal isolator and mounting eye ) D Electronic transmitter 3300 pf range 1 Further designs Order code Please add "-Z" to and specify Order code(s). Insertion length, specify in plain text: Y01 Y01:... mm Stainless steel tag [69 x 0 mm (2.71 x 1.97")]: Y1 Measuring-point number/identification (max. 16 characters) specify in plain text Acceptance test certificate: Manufacturer's test C11 certificate M to DIN 30, Part 18 and ISO 9000 Inspection Certificate Type 3.1 per EN 10204 C12 Instruction manual English French German Spanish Note: The instruction manual should be ordered as a separate line item on the order. This device is shipped with the Siemens Milltronics manual CD containing the complete ATEX Quick Start and instruction manual library. 7ML1998-HE01 7ML1998-HE11 7ML1998-HE31 7ML1998-HE21 /264 Siemens FI 01 2010

Level instruments, threaded An inverse frequency shift capacitance continuous 7 M L 6 2-7 7 7 77-77 A 7 Accessories ½" NPT cable gland, nickel plated brass, fits cable 7ML1830-1JA diameter 6 to 12 mm (0.24 to 0.47") -40 to +100 C (-40 to +212 F), IP68 (General Purpose) ½" NPT cable gland, brass, ATEX II 2GD EEx d IIC 7ML1830-1JB and EEx e II, fits cable diameter 6. to 14 mm (0.26 to 0."), -60 to +130 C (-76 to +266 F), IP68 (Explosion Proof) M20x1. cable gland, PA polyamide, ATEX II 2G 7ML1830-1JC EEx e II, fits cable diameter 7 to 12 mm (0.28 to 0.47"), -20 to +70 C (-4 to +18 F), IP68 (General Purpose) M20x1. cable gland, brass, ATEX II 2GD EEx d IIC 7ML1830-1JD and EEx e II, fits cable diameter 10. to 1.9 mm (0.41 to 0.63"), under armour cable diameter 6.1 to 11. mm (0.24 to 0.4"), -60 to +130 C (-76 to +266 F), IP68 (Explosion Proof) Electronic transmitter kit C) 7ML1830-1KN (includes transmitter and driver) SITRANS RD100 Remote display - see RD100 on page /304 SITRANS RD200 Remote display - see RD200 on page /306 1) Custom shipping methods required. Contact factory for more details 2) For process connections 1½" and larger 3) Available for rod versions only 4) Thermal isolator is used if process connection temperature exceeds +8 C (+18 F). ) Available for cable versions 0E to 4E only C) Subject to export regulations AL: N, ECCN: EAR99 Siemens FI 01 2010 /26

, welded flange 7 M L 6 2 6 - An inverse frequency shift capacitance continuous 7 7 7 77-77 A 7 Version (lengths from flange face) Rod, 300 to 1000 mm (11.81 to 39.37") 0 A 1001 to 2000 mm (39.41 to 78.74") 1 A 2001 to 3000 mm (78.78 to 118.11") 1) 2 A 3001 to 4000 mm 118.1 to 17.48") 1) 3 A 4001 to 000 mm (17.2 to 196.8") 1) 4 A Rod, with stilling well 300 to 1000 mm (11.81 to 39.37") 2) 0 B 1001 to 2000 mm (39.41 to 78.74") 2) 1 B 1) 2) 2001 to 3000 mm (78.78 to 118.11") 2 B 1) 2) 3001 to 4000 mm (118.1 to 17.48") 3 B 1) 2) 4001 to 000 mm (17.2 to 196.8") 4 B Cable,, weighted 1000 to 2000 mm (39.37 to 78.74") 2) 0 E 2001 to 4000 mm (78.78 to 17.48") 2) 1 E 4001 to 6000 mm (17.2 to 236.22") 2) 2 E 6001 to 8000 mm (236.26 to 314.96") 2) 3 E 8001 to 10000 mm (31 to 393.70") 2) 4 E Cable, non-insulated, weighted (non-conductive media only) 1000 to 2000 mm (39.37 to 78.74") 2) 0 F 2001 to 4000 mm (78.78 to 17.48") 2) 1 F 4001 to 6000 mm (17.2 to 236.22") 2) 2 F 6001 to 8000 mm (236.26 to 314.96") 2) 3 F 8001 to 10000 mm (31 to 393.70") 2) 4 F Cable lengths up to 2000 mm (984.2") are possible for non-conductive media. Cable lengths up to 1000 mm (90.") are possible for conductive media. Contact nacc.smpi@siemens.com for details. Process connection Welded flange, 316L, raised face 1" ASME 10 lb 3) A 1 1" ASME 300 lb 3) A 2 1" ASME 600 lb 3) A 3 1½" ASME 10 lb B 1 1½" ASME 300 lb B 2 1½" ASME 600 lb B 3 2" ASME 10 lb C 1 2" ASME 300 lb C 2 2" ASME 600 lb C 3 3" ASME 10 lb D 1 3" ASME 300 lb 1) D 2 3" ASME 600 lb 1) D 3 4" ASME 10 lb 1) E 1 4" ASME 300 lb 1) E 2 4" ASME 600 lb 1) E 3 Welded flange, 316L, Type A flat faced DN 2, PN 16 3) J 4 DN 2, PN 40 3) J 6 DN 40, PN 16 K 4 DN 40, PN 40 K 6 DN 0, PN 16 L 4 DN 0, PN 40 L 6 DN 80, PN 16 M 4 DN 80, PN 40 1) M 6 DN 100, PN 16 1) N 4, welded flange 7 M L 6 2 6 - An inverse frequency shift capacitance continuous 7 7 7 77-77 A 7 DN 100, PN 40 1) N 6 (Note: Flange bolting patterns and facings dimensionally correspond to the applicable ASME B16., or EN 1092-1 standard.) Approvals General purpose: CE, CSA, FM, C-TICK 1 CSA/FM Class II and III, Div. 1, Groups E, F, G T4; 2 ATEX II 1/2 D T100 C ATEX II 1/2 G EEx d [ia] IIC T6 to T1 3 CSA/FM Class I, Div. 1, Groups A, B, C, D T4 4 Enclosure Aluminum, epoxy-coated Cable entry 2 x ½" NPT, IP6 0 Cable entry 2 x M20x1., IP6 1 Cable entry 2 x ½" NPT, IP68 2 Cable entry 2 x M20x1., IP68 3 Thermal isolator 4) None A With thermal isolator B With mounting eye ) C With thermal isolator and mounting eye ) D Electronic transmitter 3300 pf range 1 Further designs Order code Please add "-Z" to and specify Order code(s). Insertion length, specify in plain text: Y01 Y01:... mm Stainless steel tag [69 x 0 mm (2.71 x 1.97")]: Y1 Measuring-point number/identification (max. 16 characters) specify in plain text Acceptance test certificate: Manufacturer's test C11 certificate M to DIN 30, Part 18 and ISO 9000 Inspection Certificate Type 3.1 per EN 10204 C12 Instruction manual English French German Spanish Note: The instruction manual should be ordered as a separate line item on the order. This device is shipped with the Siemens Milltronics manual CD containing the complete ATEX Quick Start and instruction manual library. 7ML1998-HE01 7ML1998-HE11 7ML1998-HE31 7ML1998-HE21 /266 Siemens FI 01 2010

Level instruments, welded flange 7 M L 6 2 6 - An inverse frequency shift capacitance continuous 7 7 7 77-77 A 7 Accessories ½" NPT cable gland, nickel plated brass, fits cable 7ML1830-1JA diameter 6 to 12 mm (0.24 to 0.47") -40 to +100 C (-40 to +212 F), IP68 (General Purpose) ½" NPT cable gland, brass, F) 7ML1830-1JB ATEX II 2GD EEx d IIC and EEx e II, fits cable diameter 6. to 14 mm (0.26 to 0."), -60 to +130 C (-76 to +266 F), IP68 (Explosion Proof) M20x1. cable gland, PA polyamide, ATEX II 2G 7ML1830-1JC EEx e II, fits cable diameter 7 to 12 mm (0.28 to 0.47"), -20 to +70 C (-4 to +18 F), IP68 (General Purpose) M20x1. cable gland, brass, ATEX II 2GD EEx d F) 7ML1830-1JD IIC and EEx e II, fits cable diameter 10. to 1.9 mm (0.41 to 0.63"), under armour cable diameter 6.1 to 11. mm (0.24 to 0.4"), -60 to +130 C (-76 to +266 F), IP68 (Explosion Proof) Electronic transmitter kit C) 7ML1830-1KN (includes transmitter and driver) SITRANS RD100 Remote display - see RD100 on page /304 SITRANS RD200 Remote display - see RD200 on page /306 1) Custom shipping methods required. Contact factory for more details 2) For process connections 1½" and larger 3) Only for use with Versions 0A to 4A 4) Thermal isolator is used if process connection temperature exceeds +8 C (+18 F). ) Available for cable versions 0E to 4E only C) Subject to export regulations AL: N, ECCN: EAR99 F) Subject to export regulations AL: 9I999, ECCN: N Siemens FI 01 2010 /267

Characteristic curves Example Process Pressure/Temperature derating curves (7ML62) /268 Siemens FI 01 2010

Level instruments Process Pressure/Temperature derating curves (7ML626) Process Pressure/Temperature derating curves (7ML626) Siemens FI 01 2010 /269

Dimensional drawings Threaded (7ML62) Threaded (7ML62) lid clip lid electronics/ enclosure 20 mm (0.79 ) 2 cable entries ½" NPT or M20x1. probe Y02 1) min. = 300 mm (14") max. = 000 mm (197") stilling well vent probe ø 19 mm (0.7") Y02 1) min. = 300 mm (14") max. = 000 mm (197") 10 mm (.91") lid without window thermal isolator M20: 13 mm (.32") ½" NPT: 10 mm (.91") 27 mm (10.83") ø 19 mm (0.7") = 30mm (1.18") Inactive tip 2) Cable version, non-insulated Threaded (7ML62) 20 mm (0.79") ø 3 mm (1.38") 3) Cable version, insulated Threaded (7ML62) Notes: 1) Rod version Y02: Shield length= 100 mm (3.9") for threaded including process connection thread length, 100 mm (3.9") for welded flange 2) For non-conductive applications only. Non-insulated cable can be shortened on site. Weight is included in. 3) For liquids and solids applications. Insulated cable cannot be shortened. Weight is not included in. 4) For conductive materials, the includes the exposed cable only. Any fluid contact with the upper rod assembly will result in a short circuit and incorrect readings. cable ø 6 mm (0.24") weight ø 32.0 mm (1.26") Y02= 10 mm (4.13") 20 mm (9.84") min. = 1000 mm (40") max. = 2000 mm (984") cable ø 9 mm (0.3") weight (electrically isolated but not PFA insulated) ø 34. mm (1.36") Y02= 10 mm (4.13") 30 mm (13.78") See note 4 min. = 1000 mm (40") max. = 2000 mm (984") ø 9 mm (0.3") ø 34. mm (1.36") mounting eye ø 2 mm (0.98") 30 mm (13.78") ø 12 mm (0.47") 20 mm (0.79") dimensions - Threaded Process Connections /270 Siemens FI 01 2010

Level instruments Welded Flange (7ML626) Welded Flange (7ML626) lid clip lid electronics/ enclosure 2 cable entries ½" NPT or M20x1. M20: 13 mm (.32") ½ NPT: 10 mm (.91") probe ø 19 mm (0.7") Y02 1) min. = 300 mm (11.81") max. = 000 mm (196.8") stilling well vent probe ø 19 mm (0.7") ø 3 mm (1.38") Y02 1) min. = 300 mm (11.81") max. = 000 mm (196.8") 10 mm (.91") lid without window thermal isolator Flange Facing (raised face) Flange Class Facing thickness ASME 10/300 2 mm (0.08") ASME 600/900 7 mm (0.28") PN 16/40 2 mm (0.08") 27 mm (10.83") = 30mm (1.18") Inactive tip cable ø 6 mm (0.24") weight 2) Cable version, non-insulated Welded flange (7ML626) ø 32.0 mm (1.26") Y02= 10 mm (4.13") 20 mm (9.84") min. = 1000 mm (39.37") max. = 2000 mm (984.2") 3) Cable version, insulated Welded Flange (7ML626) cable ø 9 mm (0.3") weight (electrically isolated but not PFA insulated) ø 34. mm (1.36") Y02= 10 mm (4.13") See note 4 30 mm (13.78") min. = 1000 mm (39.37") max. = 2000 mm (984.2") Notes: 1) Rod version Y02: Shield length= 100 mm (3.9") for threaded including process connection thread length, 100 mm (3.9") for welded flange 2) For non-conductive applications only. Non insulated cable can be shortened on site. Weight is included in. 3) For liquids and solids applications. Insulated cable cannot be shortened. Weight is not included in. 4) For conductive materials, the includes the exposed cable only. Any fluid contact with the upper rod assembly will result in a short circuit and incorrect readings. ø 9 mm (0.3") ø 34. mm (1.36") mounting eye ø 2 mm (0.98") 30 mm (13.78") ø 12 mm (0.47") 20 mm (0.79") dimensions - Flanged Process Connections Siemens FI 01 2010 /271

Schematics connections /272 Siemens FI 01 2010