System 13. ü ( System 13

Similar documents
APPLICATION OF SYSTEM 8

System 6. ü ( System 6

System 8. Solenoid Coils Armature Assemblies Valve Systems. Nass Controls LP Nass Magnet GmbH Precision Controls Kft.

System 6. Solenoid Coils Armature Assemblies Valve Systems

SOGEAC SOLENOID VALVE NASS MAGNET: SYSTEM 8. s.r.l.

nickel-plated brass - PBT technopolymer HNBR, FKM stainless steel

Solenoid System FLANGE MOUNTING VERSION

nickel-plated brass - PBT technopolymer HNBR, FKM stainless steel

Solenoid System KNURLED NUT TOP CORE GUIDE TUBE PLUNGER

EVI 5 S13 Solenoid System

15 mm Pilot Valve. More technical specifications are reported in the following pages. 1

2/2-way, 3/2-way NC and NO. Monostable - bistable (with magnetic memory) Ports M5 and G1/8 - cartridge ø4

Valve: brass guiding tube plunger and core made by a magnetic stainless steel specially designed for solenoid applications polyester valve body

3/2-way Rocker Solenoid Valve for pneumatic systems

Solenoid System. The coil is also in conformity with 94/9/EC ATEX for electrical apparatus of group II, category 3 (Ex na II 3 GD T4 or T5).

Series P directly operated solenoid valves

2/2-way Solenoid Valve with servo diaphragm

Type 2511/12. Type Type 2030 Cable plug. ASI cable plug. Dosing control. General technical data Orifice Type 6518

3/2-5/2 ports / positions

3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics

3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics

MINI-SOLENOID VALVES ISO (CNOMO, size 15) interface direct operated, pad mounting body connector size 15

Series PD directly operated solenoid valves

Directional Control Valve Series D3W Soft Shift

SOLENOID VALVES AND PNEUMATIC VALVES

3/2-way Solenoid Valve, direct-acting, NC or NO

Technical Data Sheet

2/2 and 3/2-way Flipper Solenoid Valve, with hermetic isolation of fluid

2/2 and 3/2-way Flipper Solenoid Valve, with hermetic isolation of fluid

Series PD directly operated solenoid valves

Solenoid valves VZWM-L, NPT

AirLINE and AirLINE Quick electrical/pneumatic Automation System

Remote Process Actuation Control System AirLINE - Rockwell 1734 Point I/O System

Direct-acting 3/2 way plunger valve

2/2-way Compact Solenoid Valve, G 1/4 - G 1/2

Remote Process Actuation Control System AirLINE - Siemens ET 200S

SPOOL VALVE. solenoid air operated 3/2 G 1/4. SPECIFICATIONS : air or neutral gas, filtered, lubricated or not PORTS : G 1/4 CONSTRUCTION

SOLENOID VALVES AND PNEUMATIC VALVES

Modular pneumatic valve island

2/2-way Solenoid Valve for liquids and gases

3/2-way Small Solenoid Valve, G 1/8 - G 1/4 and sub-base

Miniature coil (3W) encapsulated in synthetic material. Connection with 3-pin DIN type B plug. Degree of protection IP 65.

3/2-way and 2 x 3/2-way Solenoid Valve for pneumatics

3/2, 5/2, 5/2 bistable and 5/3 way pneumatic solenoid valve

Pilot-Operated Directional Control Valves Series D3 - D11

3/2 Directional Control Valves Direct solenoid operated poppet valves Internal thread G1/4, 1/4-18 NPT or flanged with NAMUR interface

Solenoid valves VZWM-L

5/2 and 5/3 Valves Solenoid and Pilot Actuated Sub-base Mounted ISO #1, #2, #3, #4 Steel reinforced main seals

2/2-way Solenoid Valve with servo diaphragm, G 3/8 - G 2

Pilot Operated Directional Control Valves Series D31DW, D41VW - D111VW

Modular pneumatic valve unit

Common wiring modules can be connected by fieldbus, multi-pole or common earth/neutral modules.

DIRECT OPERATED SOLENOID PILOT VALVES Product Index

PRM2-06. Functional Description HA /2014. Proportional Directional Control Valves. Replaces HA /2013. Size 06 p max 350 bar Q max 40 L/min

Solenoid valve Types EV220B 15 - EV220B 50

Servo-operated 2/2-way solenoid valves Type EV220A

3/2-way Miniature Rocker Solenoid Valve for pneumatic systems

2/ VDMA (ISO ) 5/2-5/3-way CC CO CP. CATALOGUE > Release 8.8 CONTROL > Series 7 valves and solenoid valves GENERAL DATA

Technical Principles of Valves

Information 3 Form A 4 Industrial Form Type B 12 Form B 16 Form C 18 Micro Type C 22

2/2-way Solenoid Valve with servo diaphragm, G 3/8 - G 2

The manifolds can be powered through various fieldbus systems, multipole or common terminals.

MINI-SOLENOID VALVES direct operated subbase mounted, CNOMO (15 mm width) connector size 15

2/2 Pressure operated valves

Solenoid Operator 0516 / 1216

Electrically operated valves Series BM-01, 3/2-way and 2 x 3/2-way G1/8 550 to 660 Nl/min (0.559 to Cv)

2/2 or 3/2-way Solenoid Valve, with pivoted armature and isolating diaphragm

Solenoid valves VZWP, servo-controlled

Direct-acting 2/2-way plunger valve

Directional Control Valve Series D1VW

Solenoid valve Types EV220B 15 - EV220B 50

3/2-way Solenoid Valve for pneumatics

SPOOL VALVES pilot operated or air operated, spool type single/dual solenoid (mono/bistable function) brass body, 1/4

High Pressure Valves

3/2-way and 2 x 3/2-way Rocker Solenoid Valve for pneumatics

Viking Xtreme Valves. High reliability Few moving parts result in high reliability, rapid changeover and very long life.

The extendable type 5470 EExi can be used for block modules or for entire valve blocks (tag connectors on top, coil spacing 19 mm).

Mounting on manifold strip. Working pressure min./max. Max. particle size 5 µm. Connector standard ISO 15217

VALVES SERIES 70, SOLENOID/PNEUMATIC

Indirect servo-operated 2/2-way solenoid valves Type EV220W 10 - EV220W 50, NBR and EPDM versions

MULTIFUNCTION SPOOL VALVES air operated and solenoid air operated G3/4-G1 - ISO 5599/1 subbase-mounted body

Excel V03, V04 and V05 Series

Directional Control Valve Series 4D01 (DENISON)

Directional Control Valve Series D3W (Parker), 4D02 (Denison)

SPOOL VALVES pilot or air operated, spool type single/dual solenoid (mono/bistable function)

3/2-way and 2 x 3/2-way Solenoid Valve for pneumatics

Proportional solenoid valve for pneumatic application V PR M

VALVES ISO 5599/1, SERIES IPV-ISV

3/2-way Miniature Rocker Solenoid Valve for pneumatic systems

2/2-way Quarter-Turn Ball Valve in stainless steel with pneumatic rotary actuator, DN 10-50

2/2-way and 3/2-way Normally Closed (NC) and Normally Open (NO)

2/2 or 3/2-way Solenoid Valve, with pivoted armature and isolating diaphragm

Assisted lift operated 2/2-way solenoid valves Type EV251B

Solenoid valves 2/2-way servo operated type EV220B 15 50

Data sheet. 2-way solenoid valves with Clip-on coils for neutral liquids and gases. January 2003 DKACV.PD.200.K B1472

SPOOL VALVES pilot operated or air operated, spool type single/dual solenoid or air (mono/bistable function) aluminium body, 1/4 to 1/2

SPOOL & SLEEVE VALVES solenoid air operated monostable / bistable function threaded ports G 1/8-G 1/4

SPOOL VALVES pilot or air operated, spool type single/dual solenoid (mono/bistable function) brass body, 1/4

Solenoid valves VZWM-L

Directional Control Valve

Transcription:

System ü www.nassmagnet.com ( +9 676-0 System

The name System stands for a modular system of solenoid coils, armature systems, solenoid operators and solenoid valves. The diameter of the armatures of all valve components is approimately mm. This value is the major characteristic of this type. The components efficiency has been increased to the optimum in years of simulation, construction and practical testing. APPLICATION OF SYSTEM The solenoid operators and solenoid valves of system can be used for operating /- or / way valves, especially in pneumatics and process technology. Available switching functions are normally closed and normally open. For / way valves of this series, typical maimum values for operating pressure and nominal width are 0 bar/ mm. The solenoid operators and solenoid valves are designed for the use with compressed air or other neutral gases. / way solenoid operators and solenoid valves can also be used for controlling non-aggressive liquids. FUNCTION While the solenoid operator/solenoid valve (standard version, / way, normally closed) is de-energized, the armature is pushed down on the lower valve seat by the reset spring. The lower valve seat is closed by a sealing element. In this switch position the upper valve seat in the magnetic core is open. When the valve is energized, the magnetic force eceeds the force of the reset spring and moves the armature into the opposite etreme position. In this case the upper valve seat is S closed by the sealing element6, whereas the lower valve seat is open. Solenoid operators and solenoid valves have identical functionality. However, if solenoid operators are ordered neither the lower valve seat nor the valve body is shipped. Those components have to be provided by the customer. / way valves do not have an upper valve seat. Besides that, the function of the magnet is identical.

SOLENOID COIL Width: Connection type: Moulding material: 0 mm form A EN 70-80-A thermoset resin General Data Voltage tolerance ± 0 % Ambient temperature - 0 C to + C Relative duty cycle 00 % Insulation class of insulating materials according to DIN VDE 080 F Degree of protection with connector according to EN 9 IP 6 (IP 67 on request) Protective class I Imprint nass magnet (customer imprint possible) S

Technical Data Standard Versions Part No. Voltage Frequency [Hz] Rated Power [W] [VA] Power Level -00-00 -00-00 -00-00 -00-00 -00-00 -00-00 -00-078 -00-006 -00-009 -00-009 -00-006 -00-006 -00-00 -00-00 -00-00 -00-007 -00-009 -00-009 -00-007 -00-007 -00-00 -00-00 -00-00 -00-007 -00-008 -00-000 -00-000 -00-00 -00-00 -00-00 -00-00 -00-008 -00-009 -00-009 -00-008 -00-00 -00-00 -00-00 -00-00 -00-00 -00-00 0 V DC 08 V DC 08 V DC 0 V AC 0 V AC 0 V AC 0 V DC 0 V DC 0 V AC 0 V AC 0 V AC 0 V AC 0 V AC 0 V AC 0 V AC 0 V DC 0 V AC 0 V AC 0 V AC 0 V AC 0 V AC 0 V AC 0 V AC 0 V DC 0 V DC 0 V AC 0 V AC 08 V AC 08 V AC 08 V AC 08 V AC 0 V AC 0 V AC 0 V AC 0 V AC 9 V DC 0 V AC 0 V AC 0 V AC 0 V AC 0 V AC 0,0 0, 0,6 06, 06,6 0,7 06,0 06, 0,8 09,6,,7 0,8 9, 7,,0 7,9,6 7,6 8, 8, 8,9,,0,0,8 9, 6,, 9,0 6,6,8,7 9, 6, 6,6,0, 9,0 7,9, [K] 00 00 00 00 00 00 0 0 0 0 0 0 0 00 090 070 090 08 090 090 090 09 0 09 09 00 090 090 [K]: steady-state over-temperature according to VDE 080 S

SOLENOID COIL Width: Connection type: Moulding material: 0 mm form A EN 70-80-A thermoplastic General Data Voltage tolerance ± 0 % Ambient temperature - 0 C to + C Relative duty cycle 00 % Insulation class of insulating materials according to DIN VDE 080 F Degree of protection with connector according to EN 9 IP 6 Protective class I Imprint nass magnet (customer imprint possible) S

Technical Data Standard Versions * [K] Part No. Voltage Frequency [Hz] Rated Power [W] [VA] Power Level -00-099 0 V DC 06, 0-00-000 0 V DC,0 080-00-00 0 V AC 7,6 00-00-00 0 V AC 8, 00-00-00 0 V AC 8, 00-00-00 0 V AC,9 09-00-00 0 V AC 7,6 00-00-00 0 V AC,9 09-00-00 0 V DC -00-006 0 V AC 9, * -00-006 0 V AC 6,0 *,0 [K]: steady-state over-temperature according to VDE 080 When using AC type models with a power rating of the maimum ambient temperature must not eceed + 0 C. S6

SOLENOID COIL Width: Connection type: Moulding material: 6 mm form A EN 70-80-A thermoset resin General Data Voltage tolerance ± 0 % Ambient temperature - 0 C to + C Relative duty cycle 00 % Insulation class of insulating materials according to DIN VDE 080 F Degree of protection with connector according to EN 9 IP 6 (IP 67 on request) Protective class I Imprint nass magnet (customer imprint possible) S7

Technical Data Standard Versions Part No. Voltage Frequency [Hz] Rated Power [W] [VA] Power Level 0, [K] -00-0 0 V DC 00-00-0 0 V AC 08,8 00-00-0 0 V AC 07,6 00-00-08 0 V AC 09,0 0-00-08 0 V AC 09, 0-00-0 0 V AC 08,8 00-00-0 0 V AC 07,6 00-00-0 0 V AC,0 0-00-0 0 V DC 0-00-0 0 V AC,0 0-00-0 0 V AC,0 0-00-079 0 V AC,9 0-00-079 0 V AC, 0-00-0 0 V DC 070-00-09 0 V AC,0 090-00-09 0 V AC 8,0 08-00-06 0 V AC, 090-00-0 0 V AC,0 090-00-0 0 V AC 9,0 08-00-00 0 V DC -00-07 0 V AC -00-0 0 V DC -00-00 06 V AC,0-00-07 0 V AC 7, -00-00 0 V AC 6, -00-07 0 V AC 8,0-00-0 0 V AC, -00-0 0 V AC,0-00-08 0 V AC, -00-0 0 V AC,0-00-08 0 V AC 7,0 07,9,9 7,,0 8, [K]: steady-state over-temperature according to VDE 080 S8

SOLENOID COIL Width: Connection type: Moulding material: 6 mm form A EN 70-80-A thermoplastic General Data Voltage tolerance ± 0 % Ambient temperature - 0 C to + C Relative duty cycle 00 % Insulation class of insulating materials according to DIN VDE 080 F Degree of protection with connector according to EN 9 IP 6 Protective class I Imprint nass magnet (customer imprint possible) S9

Technical Data Standard Versions * [K] Part No. Voltage Frequency [Hz] Rated Power [W] [VA] Power Level -00-088 0 V DC 07,9 0-00-089 0 V DC,9 080-00-000 0 V AC -00-090 0 V DC *,8 8, [K]: steady-state over-temperature according to VDE 080 When using AC type models with a power rating of the maimum ambient temperature must not eceed + 0 C. In this power level, AC versions are not possible. S0

SPECIAL REMARKS Width: 0 mm Connection type: form A Moulding material: thermoset resin and thermoplastic Width: 6 mm Connection type: form A Moulding material: thermoset resin and thermoplastic Note: The proportions of the solenoid coils displayed in the images on this page do not represent the actual proportions. S The technical data are valid for the indicated standard voltages. Other voltages are available on request. Perfect function of these solenoid coils with the pertinent components included in this catalogue is assured with the winding having reached its operating temperature (ma. ambient temperature and ma. voltage tolerance). The steady-state over-temperature is reached in case of valve body of plastic and encapsulation made of Thermoplastic. All devices are designed in compliance with DIN VDE 080. Arrangement of the devices in modular design is possible, however, it may ensue a higher temperature increased by up to 0 K and may limit the function. A general lifetime of the products cannot be specified, as it is decisively influenced by ambient conditions, the single application and combination with other components. The function can only be fulfilled in case of eclusive use of nass magnet products. Should there be deviating or additional operating conditions compared to the above-mentioned conditions, special testing is necessary in order to verify the usability of the nass magnet products. nass magnet will be glad to give you the required advice.

ARMATURE ASSEMBLY GW (THREAD) Switching function: De-energized state: Connection type: / and / way NC (normally closed), NO (normally open) thread M 0, metal sealing or with O ring shading ring for AC versions (without nonferrous metal on request) General Data Ambient temperature - 0 C to + C Sealing Material FKM (other sealing materials on request) Quality of medium according to ISO 87- when using FKM sealing elements compressed quality air class,, Mounting position any (preferably plunger in vertical direction) / way NC S / way NC / way N0

Technical Data Standard Versions Part No. Function Power Level Nominal Orifice [mm] inlet ehaust Pressure [bar] Thread M 0 metal O ring sealing sealing Armature Guide brass stainless steel -00-006 / way NC,, 0-00-00 / way NC,0, 0-00-00 / way NC,, -00-00 / way NC,, -00-00 / way NC,, -00-00 / way NC, 0-00-006 / way NO -00-007 / way NC,,0 0-00-000 / way NC,0, 0-00-008 / way NC,0, 0-00-006 / way NO,0 Power Levels for / Way Versions AC - Hz Power Level AC - Hz DC - % residual ripple ma. test pressure: 8 bar special versions on request Power Level Power Level S

ARMATURE ASSEMBLY FL (FLANGE) Switching function: De-energized state: Connection type: / and / way NC (normally closed) flange with O ring shading ring for AC versions (without nonferrous metal on request) General Data Ambient temperature - 0 C to + C Sealing Material FKM (other sealing materials on request) Quality of medium according to ISO 87- compressed quality air class,, Mounting position any (preferably plunger in vertical direction) / way NC S / way NC

Technical Data Standard Versions Part No. Function Power Level Nominal Orifice [mm] inlet ehaust Pressure [bar] Armature Guide brass stainless steel -00-007 / way NC,, 0-00-00 / way NC,0, 0-00-00 / way NC,0, 0-00-00 / way NC,, -00-00 / way NC,,0 0-00-009 / way NC,0, 0-00-00 / way NC,0, 0 Power Levels for / Way Versions AC - Hz AC - Hz DC - % residual ripple Power Level Power Level Power Level Power Level ma. test pressure: 8 bar special versions on request S

VALVE SYSTEM CNOMO Switching function: De-energized state: Valve bo: Armature Guide: / way NC (normally closed) Zinc die-casted stainless steel General Data Ambient temperature - 0 C to + C Sealing Material FKM (other sealing materials on request) Quality of medium according to ISO 87- compressed quality air class,, Mounting position any (preferably plunger in vertical direction) without manual override, NC bistable manual override, NC monostable manual override, NC Pneumatic Diagram without manual override, NC S6 bistable manual override, NC monostable manual override, NC

Technical Data Standard Versions Part No. Power Level Nominal Orifice [mm] inlet ehaust Flow Rate [l/min] Manual Override bistable monostable -0-000,, 0 07-0-006,, 0 07-0-008,, 0 07-0-000,0, 00 7-0-007,0, 00 7-0-000,,0 00-0-0007,0, 6 0-0-0008,0, 6 0-0-00,0, 6 0 All of the valve systems listed here are suitable for both AC and DC applications. qv flow rate at an inlet pressure of 6 bar ( X = bar) and 0 C; flow rate detection in compliance with ISO 68 S7

Heagon nut Eplanation: Ehaust protector -080-000 tightening torque ma. Nm; use with spring washer -080-00 Spring washer Eplanation: -080-000 tightening torque ma. Nm; use with spring washer -080-00 Mounting plate -080-00 Eplanation: -70-000 only for armature assembly FL Valve seat orifice size, Valve seat orifice size, S8-0-000-0-000

Valve seat orifice size,0 Valve seat orifice size, -0-000 Valve seat orifice size,0-0-000-0-000 O ring FKM 8,0, mm Eplanation: 900-8-008 for armature assemblies with thread; not metallic self-sealing Cheese-head screw M mm Eplanation: 900-8-00 with slots and cross slots; only for valve system CNOMO (for one valve system two srews are required); tightening torque ma.. Nm S9

PNEUMATIC CONNECTION SOLENOID OPERATOR Thread Version with Metallic Seal Thread Version with O ring Seal Flange Version with O ring Seal Note: Specifications regarding the characteristic of the customer interface are available at nass magnet on request. S0