DATA FOR AUTOMATIC AND REMOTE CONTROL OF MACHINERY SYSTEM

Similar documents
1 Name any 5stationary parts and moving partsof a large 2-stroke diesel engine?

OPERATIONS SEAFARER CERTIFICATION GUIDANCE NOTE SA MARITIME QUALIFICATIONS CODE. Deck: Ship s Power Plants

Alarms, remote indications and safeguards for main reciprocating I.C. engines installed in unattended machinery spaces

Diesel Engine Operation I. PREPARATION FOR STARTING

INTERNATIONAL ASSOCIATION OF CLASSIFICATION SOCIETIES. Requirements concerning MACHINERY INSTALLATIONS

INTERNATIONAL ASSOCIATION OF CLASSIFICATION SOCIETIES. Requirements concerning MACHINERY INSTALLATIONS

Part 5 Machinery Installations

OPERATIONS SEAFARER CERTIFICATION GUIDANCE NOTE. Level 3 Assessment Chief and Second Engineer <3000kW

National Maritime Center

Low Speed Engine Room W-Xpert W-X72 Simulator

RULES FOR THE CONSTRUCTION AND CLASSIFICATION OF SHIPS IDENTIFIED BY THEIR MISSIONS CHAPTERS APPROACH

Section 3 Technical Information

CATERPILLAR 3516B DP2 System

Not to be reproduced without permission Last date for receipt of BIS or used as STANDARD of comments 15 September 2011

CLASS STATUS REPORT WADI SAHAM FUJAIRAH PORT AUTHORITY. Report date: IMO number: DNV GL number: 28725

copyright c 2014 Hyundai Heavy Industries A Jan. 2014

National Maritime Center

PRIME MOVER CONTROLS INC. MARINE PROPULSION CONTROLS. Series MPC-CP SYSTEM

Universidad Nacional Experimental Marítima del Caribe Vicerrectorado Académico Coordinación de Idiomas English VI. Maritime Engineering

FINAL EXAM. 1. Fill in the gaps with the appropriate word from the list. (30 p.) A. two points operates injecting stroke

MARINE PROPULSION CONTROL

ENGINE 3116 PRODUCT RANGE

SFOC Optimisation with Low Load or Part Load Exhaust Gas Bypass (LL-EGB, PL-EGB)

CHAPTER II-1 C. Construction subdivision and stability, machinery and electrical installations

MAN B&W ME Engine Description. Page 1 of 6. Frame Box

MAN Diesel & Turbo. Main Engine Room Data. Project name BrasNave 25 Project type Project number 3 Date 2010 Yard

TM &P TECHNICAL MANUAL

GENERAL The Honeywell model TFE731-40AR turbofan engine is a lightweight, two-spool, geared-stage, front-fan, jet engine.

National Maritime Center

MERS. MERS Presentation MITSUBISHI ENERGY RECOVERY SYSTEM FOR MOTOR VESSELS. Feb., Engineering Dept., Marine Machinery Div.

Task By Course 7.1D This task is covered for engineers in the Leadership and Managerial Skills course

IMO UNIFIED INTERPRETATIONS TO SOLAS CHAPTER II-2, THE FSS CODE AND RELATED FIRE TEST PROCEDURES

Appendix B6 Gas Turbine Unit Cause Codes

Possible Change of Ship Design Including Engine Room about Emissions of NOx and SOx

Information Type: Date: 2014/5/14 Profile: WLO, L150G [GB] Service Information

Document Code: 1 (8) Issuing date: Status:

PART 8 MACHINERY INSTALLATIONS

.3 Section Concrete Forms and Accessories: Installation of Anchor Devices, Setting Templates

Lubrication & Cooling Systems

National Maritime Center

Technical Specification

MACHINERY SYSTEMS, GENERAL

Heat engine. Heat engine

TECHNICAL MANUAL OPERATOR S, UNIT, INTERMEDIATE (DS) AND INTERMEDIATE (GS) MAINTENANCE MANUAL FOR

Internal Combustion Engines

Parts Book. VGT series engine

Page 1 of 5. Project : CATERPILLAR CM GENSETS PROJECT (RADIATOR COOLING) 2 x 16CM32, 6.3 kv, 50 Hz. TUS(S)PL Supply. Customer Supply DESCRIPTION

UNIT IV INTERNAL COMBUSTION ENGINES

MARINE PROPULSION CONTROL

JCB DIESEL GENERATOR TECHNICAL SPECIFICATIONS

Chapter 14 Small Gas Engines

ADVANTAGES OF GTE s Weight reduction of 70% Simplicity Reduced manning requirements Quicker response time Faster Acceleration/deceleration Modular rep

National Maritime Center

INTERNATIONAL ASSOCIATION OF CLASSIFICATION SOCIETIES. Requirements concerning MACHINERY INSTALLATIONS

Chapter 6. Supercharging

MAN Energy Solutions

Introducing the Sea-Doo 4-TEC SUPERCHARGED

KAWASAKI Environment-friendly New engine technology

Global. MTS Global Co., Ltd. Your Reliable Total Service Partner. Since 2004

Mitsubishi Diesel Engine Generators (Year 2008) Model: S12R-PTA (1250 kva, 3300V, 50Hz)

Approved by AICTE, Government of India & affiliated to Dr. A.P.J. Abdul Kalam Technical University, Lucknow Department of Mechanical Engineering

ENGINEERING DEPARTMENT CRUISE 250. Summer 2011 SEA TRAINING II

Dual-Fuel-Electric Propulsion Machinery Concept on LNG Carriers

RULES FOR THE CLASSIFICATION AND CONSTRUCTION OF SEA-GOING SHIPS

IACS UR s and Panel Responsible

FOR CLASSIFICATION AND CONSTRUCTION OF INLAND WATERWAYS VESSELS MACHINERY AND PIPING SYSTEMS 2005

MACHINERY INSTALLATIONS

COOPERATIVE PATENT CLASSIFICATION

JCB DIESEL GENERATOR TECHNICAL SPECIFICATIONS

30,668 MWe POWER PLANT (7 x TBG 632 V 16 DEUTZ + 1 x TCG 2032 V16 MWM ENGINES) ON SALE. From OWNER

FD68 BURNERS SELECTION GUIDE & ENGINEERING SPECS

Power Flame Incorporated

Global VPI Insulated Indirectly Hydrogen-Cooled Turbine Generator for Single-Shaft Type Combined Cycle Power Generation Facilities

CERTIFICATES OF COMPETENCY IN THE MERCHANT NAVY - MARINE ENGINEER OFFICER

HIGH FUEL PRESSURE LINE

Wärtsilä 46F PRODUCT GUIDE

This information covers the design and function of the intake and exhaust systems for the Volvo D16F engine.

General In-line four stroke diesel engine with direct injection. Rotation direction, anti-clockwise viewed towards flywheel

Diesel Engine Power Plants

12,78 779, Bore , ,22 Compression ratio. 18,1:1 Wet weight. Engine incl. cooling system, air filtration system, and frame

General In-line four stroke diesel engine with direct injection. Rotation direction, anti-clockwise viewed towards flywheel

GOVERNMENT ENGINEERING COLLEGE, GODHRA

EC 200 EC 300 GE 360 GE 400 GE 600 L-S BM

STEAM PLANT AUTOMATION WITH BRIDGE CONTROL ON SELF-UNLOADING BULK CARRIER CASON J. CALLAWAY

Industrial Mechanic (Millwright) Level 3

1983 BMW 320i. 1.8L 4-CYL 1983 Engines - 1.8L 4-Cylinder Engines - 1.8L 4-Cylinder

Systems Operation Testing and Adjusting

Class Status Report Current Status. SÆFARI Vegagerdin

JCB DIESEL GENERATOR TECHNICAL SPECIFICATIONS

TAD1661VE

Summary of Revision, IEEE C , Guide for Breaker Failure Protection of Power Circuit Breakers

CONCEPTUAL DESIGN OF A NEW TYPE OF ENGINE FOR VARIOUS APPLICATIONS WITH EXPECTED 10% HIGHER OVERALL EFFICIENCY

Section 13 - E. 1 of 18. Engine Systems

7,15 436, Bore , ,12 Compression ratio 18 Wet weight. Engine incl. cooling system and air filtration system

2ND EXAM OF MAIN MACHINERY AND AUXILIARY MARINE SYSTEMS

KSL VARIABLE FILL FLUID COUPLINGS

OVID Refresher Inspector Course. A Guide to the uniform inspection procedure OVID

GMP-Type. Key Features: Integrated Motor-Pump Units

Volkswagen New Beetle 1.8 Liter 4-Cyl. 5V Turbo OBD II Engine Mechanical 19 Engine-Cooling system (Page GR-19)

Kawasaki turbo chiller using water as a refrigerant. Feb. 4 th 2015 Kawasaki Heavy Industries, Ltd. Machinery Division Hayato Sakamoto

Transcription:

DATA-DF(2004.6) SHIPBUILDER: HULL NO.: DATA FOR AUTOMATIC AND REMOTE CONTROL OF MACHINERY SYSTEM Diesel Ship NIPPON KAIJI KYOKAI

Summary of Description 1. If the ships are designed in accordance with description of each column, marked 1 is to be entered in. 2. If applicable, letter or figure is to be entered in( ). 3. If Note is necessary, blank space may be used additionally. Contents 1.General 1 (4)Automatic Control System 6 2.Location of Engine Control Room 1 (5)Safety System 7 3.M/E & Propulsion Shafting System 1 (1)Control Station 1 (2)Safety System 2 6.Auxiliary Machinery 8 (1)Control of Pumps, Compressors & Fans 8 (2)Level & Temp. Control for Tanks 11 (3)Control of Heat Exchangers etc. 12 4.Boiler 3 (4)Safety System 13 (1)Control Station 3 (ⅰ)Auto. Stop for Engine & Turbine 13 (2)Automatic Control System 3 (ⅱ)Auto. Stop for Compressor 13 (3)Safety System 4 7.Monitoring & Alarm System 14 5.Main Electric Generating Plant 4 (1)General 14 (1)Kind & No. of Generating Plant 4 (2)List of measuring & Alarm Point 14 (2)Location of Main Switchboard 4 (3)Control Station 5 8.Others 17

1.General The notation (MC) is acquired. The notation (MO) is acquired.[ MO A, MO B, MO C, MO D] 2.Location of Engine Control Room In engine room( )Deck Outside engine room( )Deck Integrated in bridge 3.Main Engine and Propulsion Shafting System (1)Control Station Item Control Station Maneuvering space Bridge Engine control space Engine control room Local Starting Stopping Main Engine Reversing Speed Control Emergency Stop C.P.P. Brade Pitch Control Clutch for Propulsion Engage Disengage Reversing Gear Ahead Neutral Astern - 1-

(2)Safety System Cause Main Engine Auto. Stop Main Eng.Auto. Load Reduction C.P.P. Blade Angle Auto. Reduction Alarm for Necessity of Manual Load Reduction (Note1) (Note1) (Note1) (Note2) Over speed ( ) Low press. of main lub. oil ( ) Low press. of crosshead bearings lub. oil ( ) Low press. of camshaft lub. oil ( ) High concentration of crank case oil mist ( ) High temp. of main lub. oil inlet ( ) High temp. of thrust bearing ( ) Low flow or non flow of cyl. oil ( ) Low press. or flow of piston cool. water(oil) ( ) High temp. of piston coolant outlet ( ) Low press. or flow of cyl. cool. water ( ) High temp. of cyl. cooling water outlet ( ) Fire or high temp. of scavenge air space ( ) High temp. of stern tube bearing ( ) ( ) ( ) ( ) ( ) (Note1)If pre-warning alarm and override device are provided, mark with (Note2)Alarming position for necessity of manual load reduction is to be entered in ( ) - 2 -

4.Boiler (1)Control Station Item Control Station Bridge Engine Control Room Local Ignition Firing Fire Extinguishing Soot Blow Emerg. Stop (2)Automatic Control System Automatic combustion control device is provided. Pressure Control System ON-OFF Control ON-LOW-HIGH-LOW-OFF Control Control of the number of firing burners Proportional control Combination control of the ( )system and( )system Others( ) Automatic feed water control device is provided. Feed Water Control System ON-OFF control of the feed water pump Feed water flow rate control by means of the feed water control valve Steam flow rate control for the feed water pump turbine Other(s)( ) - 3 -

(3)Safety System Fuel oil shut off Cause Fuel oil Shut off Cause Miss fire Source failure Flame failure Low temp. of fuel oil Abnormal low water level High temp.of exhaust gas Combustion air failure High temp. of fuel oil Low press. of fuel oil Low press. of atomizing steam Abnormal high temp. of thermal oil Low level of expansion tank for thermal oil Low flow rate/low differential Pressure of thermal oil 5.Main Electric Generating Plant (1)Kind & Number of Main Elect. Diesel generator ( Steam Turbine Generator ( Main shaft driven or main engine driven Generator ( )Sets )Sets )Sets Others( ) ( )Sets (2)Location of Main Switchboard In engine control room Outside engine control room - 4 -

(3)Control Station Item Control Station Bridge Engine Control Room Main Switchboard Engine Side Starting Stopping Diesel Generator Speed control Breaker close & open Stand by Selection Emergency stop Starting Stopping Steam Turbine Generator Speed control Breaker close & open Emergency stop Synchronizing Load sharing - 5 -

(4) Automatic Control System The automatic synchronizing device is provided. The automatic load sharing device is provided. The automatic starting device for stand by generator is provided. The automatic control device of number of generators on line is provided. If the exhaust gas turbine generator is provided, -The following means are provided against reduction of main engine output. The boiler is automatically fired to supply steam without interruption for electric generation. The turbine generator is automatically transferred to the stand by generator. Others( ) -Detecting means for reduction of main engine output are as follows: No. of main engine revolutions Temp.of main engine exhaust gas Press. of boiler or turbine inlet steam Temp. of steam Main engine fuel handle position Engine telegraph handle position Frequency Voltage Other(s)( ) The optimum load sharing control system is adopted during parallel operation with other generators. If the main shaft or main engine driven generator (herein after refered to as shaft generator ) is provided, -A constant frequency control equipment (constant speed control equipment) is provided as follows: Hydraulic multiple disc clutch Thyristerconverter inverter Differential epicycle gear Eddy current coupling (Electromagnetic clutch) Hydraulic oil converter (Hydraulic oil pump/ Motor control) Other(s)( ) - 6 -

- The shaft generator is also driven by any other prime mover than main engine. -In the case of reduction in the main engine speed, means are provided as follows: The shaft generator is automatically transferred to the stand by generator. The driving power for the shaft generator is automatically transferred to a separate prime mover as used for back up. Others( ) -Detecting means for reduction of main engine speed are as follows: Main engine fuel oil handle position Frequency Engine telegraph handle position Voltage Others( ) (5)Safety System Kind Auto. Stop Cause Auto. Stop Cause Over speed Low press. of cyl. cooling water engine inlet Diesel Generator Low press. of lub. oil engine inlet Low flow of cyl. cooling water engine inlet High temp. of lub. oil engine inlet High concentration of crank case oil mist High temp. of cyl. cooling water engine outlet Over speed Excessive axial displacement of rotor Steam Turbine Generator Low press. of lub. oil turbine inlet High press. of back press. (low vacuum of aux. condenser) Excessive vibration of rotor or casing - 7 -

6.Auxiliary Machinery (1)Control of Pumps, Compressors and Ventilation Fans Item Bridge Remote start and stop Eng. Control Room ( ) Auto. Start Stop Auto. Change to ST/BY Machine Sequential Start Start Stop Start Stop Start Stop Start Stop Main lub. oil pump Crosshead lub. oil pump Turbo charger lub. oil pump Camshaft lub. oil pump Reduction gear lub. oil pump Main diesel engine and propulsion shafting systems Cyl. cooling pump Piston cooling pump Fuel valve cooling pump Main cooling sea water pump Fuel oil supply pump C.P.P. control oil pump Stern tube lub. oil pump Aux. blower - 8 -

Item Bridge Remote Start and Stop Eng. Control Room ( ) Auto. Start Stop Auto Change to ST/BY Machine Sequential Start Start Stop Start Stop Start Stop Start Stop Feed water pump (Main) Feed water pump (aux.) Boiler water circulating pump Burning pump Aux. boile Forced draft fan Thermal fluid oil circulating pump Stand by lub. oil pump Lub. oil priming pump Generator diesel Cyl. cooling pump Cooler cooling sea water pump Fuel oil supply pump Generator steam diesel Stand by lub. oil pump Cieculating (cooling sea water) pump Condensate pump - 9 -

Item Bridge Remote Start and Stop Eng. Control Room ( ) Auto. Start Stop Start Stop Start Stop Start Stop Start Stop Auto Change to ST/BY Machine Sequential Start Generator steam turbine Vacuum pump Bilge pump Ballast pump G.S pump (for fire,bilge) Ballast pump (for fire, bilge) ( ) pump (for fire, bilge) Diesel fuel oil transfer pump Heavy fuel oil transfer pump Auxiliaries Steering gear oil pump Main air compressor Aux. Air compressor Control air compressor Ventilation fan in engine room Exhaust fan for purifier space - 10-

(2)Level and Temperature Control for Tanks Heating Heating Item Auto. Transfer to tank Provided Auto. Temp.Cont. Item Auto. Transfer to tank Provided Auto. Temp.Cont. Heavy fuel oil settling tank Save all tank Heavy fuel oil service tank Drain tank Diesel fuel oil settling tank Sludge tank Fuel oil tanks Diesel fuel oil service tank Fuel valve cooling oil tank Blend oil tank West oil tank Others Cascade tank - 11-

(3) Control of Heat Exchangers etc. Item Auto Control Item Auto Control Temp.,main lub. oil Temp.,lub.oil Temp.,turbo charger lub. oil Temp.,cyl. cooling water Generator diesel Temp.,camshaft lub. oil Temp.,fuel oil Viscosity,fuel oil Temp.,cyl. cooling water Main engine and propulsion shafting systems Temp.,piston cooling water (oil) Temp.,fuel valve cooling water (oil) Temp.,lub.oil Press.,gland steam Temp.,fuel oil Level,aux. condenser 燃料油粘度 Generator steam turbine Viscosity, fuel oil Temp.,scavenging air Temp.,fuel oil purifier inlet Temp.,stern tube lub. oil Temp.,lub. oil purifier inlet Temp.,reduction gear lub. oil Temp.,starting air compressor cooling water Others Temp.,fuel oil Aux. boiler Temp.,feed water - 12 -

(4) Safety system (ⅰ)Automatic stop for diesel engine and steam turbine Service Kind of Prime Movers (Note) Over speed Low press. of lub. oil High temp. of cooling water Low vacuum Low press. of or high ex coolingwater haust steam press. Excessive vibration Air compressor D T Feed water pump D T Ballast pump D T D T D T (Note) D(Diesel Engine) and T(Steam Turbine) should be enclosed with a circle according to kind of prime mover. (ⅱ)Automatic stop for air compressor Service Low press. of lub. oil Low press.of cooling water Low flow of cooling water High temp. of Compressed air Main air compressor Aux.air compressor Control air compressor - 13 -

7.Monitoring and Alarm System (1)General -The CRT displays and associating apparatus are adopted for the monitoring and alarm system. Equipments Location Maneuvering space Bridge Engine con trol space Engine control room Cargo control room CRT Display For engine ( ) Sets ( ) Sets ( ) Sets ( ) Sets ( ) Sets ( ) Sets For cargo ( ) ( ) ( ) ( ) ( ) ( ) Typewriter ( ) ( ) ( ) ( ) ( ) ( ) Printer ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) -The extension alarm devices are provided at the following stations Each engineer s accommodation room Recreation room Office Dining room Saloon Bridge Others(,,, ) (2)List of measuring point and alarm point for machinery system List of measuring and alarm point for machinery system should be attached to this booklet. The format of the list is free provided that the list is at least included such the list of measurement, indication and alarm as shown to the following example. Attached from may be used to make the list, if necessary. - 14 -

For example List of measuring and alarm point for machinery system Object/ Division Location Item Maneuvering space Bridge Engine con trol space Engine control room Work Shop Note Revolution 1 1 1 Temp. of exhaust gas each cyl. outlet 1 1 1 Press. of governor setting air 1 1 Ahead/Astern indication of cam shaft 1 1 Indication Aux. blower running 1 1 High Temp. of cooling water each cyl. outlet 1 1 High & Low Temp. of F. O. injection pump inlet 1 1 Main Engine Temp. Low press. of main L. O. inlet 1 1 Alarms Low press. of control air 1 1 1 High differential press. L. O. filter 1 1 Press. -15-

List of measuring and alarm point for machinery system Object/ Division Location Item Maneuvering space Bridge Engine con trol space Engine control room (Note) This sheet may be copied, if necessary. Note -16-

8.Others Devices for stand by sequence control of machinery system are provided. Local Area Network (LAN) system is adopted. Condition monitoring devices of machinery system are provided. Voice control devices are used for the following purpose. Purpose Voice alarm devices are adopted for the following system. System Electronic control devices for main engine are provided for the following system. System Electronic speed governing system Cylinder oil timing control system Others( ) - 17 -