Series CA6 Contactors

Similar documents
Technical Information

Series CA6 Contactors

Bulletin 100-D IEC Contactors

Series CA5 Contactors

Technical Information

Technical Information

and Refrigeration Institute). CNX Special Purpose Contactors

The contactor for large horsepower applications

General + Definite Purpose Contactors

General + Definite Purpose Contactors

Technical Information

MAKING MODERN LIVING POSSIBLE. Technical brochure. Minicontactors CI 5-

A Contactors. Technical Information. CA4 Miniature Contactors. Technical Information A94 CA4. Switching Motor Loads.

Contactor Types CI 61-98

Mini Contactors CI 4-

CI-TI TM Contactors and Motor Starters Contactors CI 6-50

Approved Standards. Motor Contactor. Main contactor. Accessoires. 21 Motor Contactor J7KN

Page 2-4 Page 2-8. Page Page 2-12

CI-TI Contactors and motor starters Types CI 61 - CI 98

A200 NEMA Contactors and Starters A200

Approved Standards. Ordering Information. Mini Contactor Relays 4-pole J7KNA-AR. Model Number Legend. Main contactor. Accessories

Model Number Legend. Motor Contactor J7KN. Motor Contactor J7KN 1

3RT14 Contactors with 3 Main Contacts

AF09... AF38 4-pole Contactors AC / DC Operated - with Screw Terminals

Controls. CONTACTORS CWB Line (up to 40A)

AF09... AF30 3-pole Contactors up to 25 HP / 600 VAC

Technical Information

CI-TI Contactors and Motor Starters Type CI 6-50

AF09... AF30 3-pole Contactors up to 20 HP / 480 VAC

Add-on blocks and accessories For BG series mini-contactors For BF series contactors For B series contactors...

Contactor Catalogue. According to CE, IEC 947, EN Pole & 4 Pole Contactors 4kW - 160kW Thermal Overload

UL & CSA Technical data A/AE9 A/AE/AF110, AL9 AL40 AC & DC operated

Short form catalogue. Motor protection & control

Page 2-4 Page 2-8. Page Page 2-13

AF series contactors (9 2650)

NEMA Space Saving Contactors and Starters

AF series contactors (9 2650)

Approved Standards. Ordering Information. Mini Motor Contactor J7KNA. Model Number Legend. Main contactor. Accessories. Mini Motor Contactor J7KNA 1

Switches Unlimited Phone: * Fax:

Manual Motor Protectors

Rotary Cam Switches. Rotary Cam Switches

RSC09 RSC16 RSC22 RSC38 RSC43 RSC63 RSC-AUX

Micro Contactor MA Series

Latch for Contactors 4-pole see page 36. Ratings Rated Aux. Contacts Type Coil voltage 2) AC2 Current Built-in Additional 24 24V= DC 5

AF40... AF96 3-pole contactors 30 to 60 hp at 480 V AC AC / DC operated with 1 N.O. + 1 N.C. auxiliary contacts

Motors Automation Energy Transmission & Distribution Coatings. Automation Contactors - CWM Line

DATASHEET - DILMC9-10(24VDC) Technical data General. Contactor, 3p+1N/O, 4kW/400V/AC3. Catalog No Eaton Catalog No. XTCEC009B10TD.

Description. Positive safety relays

Application Description

TABLE OF CONTENTS. Description Page Description Page. SETI Finland. Approvals:

xxx.1xx xxx.4xx0. AgNi contacts, specifically intended for resistive and slightly inductive loads as well as for motor loads

System pro M compact Miniature Circuit Breaker SU200 M for branch circuit protection acc. to UL 489

Bulletin 100-D IEC Contactors

GV2, GV3, and GV7 Manual Motor Starters, Controllers, and Protectors Standard Features

Capacitor Switching Contactors Type K3...-A, K3...-K

TeSys contactors. Use in category DC-1 (resistive loads; time constant L/R y 1 ms) Rated operational current Ie. to be wired in series

Technical Information

Bulletin 193-T1 Bimetallic Overload Relays

C -5 to +55 (0.8 to 1.1Uc) Permissible o

For many applications

Motor Controllers + Circuit Breakers

3. Coils shall be of molded construction

Electrical sector solutions E Line family. Industry leading design in a compact package

TAE pole Contactors

SENTRON Switching and Protection Devices Switch Disconnectors

Phone: Fax: Web: -

Electrical sector solutions E Line family. Industry leading design in a compact package

Selection Guide Motor Control Device Solutions

4 - Miniature controls

F Motor Circuit Controllers. Series KT7 Motor Circuit Controllers. KT4 Manual Motor Starters. General Description...F2

Circuit-Breakers M4 166 for motor protection. Auxiliary contacts 167 Signalling switch Auxiliary releases

Industrial Contactors CTX 3 3P 185A - 800A

Star Series Motor protection & control

Series CA7 Contactors

MPW Series. MPW Catalog Number Sequence. Standard Features MPW U004

Contactors. 1.1 E Line contactors. 1.2 xstart series contactors. 1.3 xstart C series contactors. 1.4 D Line contactors.

ASL09..S 3-pole Contactors - Spring Terminals

AF / AF12Z pole Contactors AC / DC Operated - with Screw Terminals

All round protection guaranteed

Manual motor protectors Type MS116 Type MS325 Type MS45X Type MS49X

Page. Circuit-Breakers M4 2 for motor protection. Auxiliary contacts 3 Signalling switch Auxiliary releases

1 3RT1016-1A**1 1 3RT1017-1A** RT1025-1A** RT1025-3A** RT1034-1A** RT1034-3A**0 175.

Softstarters Type PSS. Softstarters. General information

AE 9... AE 40 Contactors NE... Contactor Relays

BETA Switching Switches and Light Indicators

3VU13, 3VU16 Circuit-Breakers

B115...B180 RF200 RFN200 B250...B400 RF400 RFN400

3 - Protection components Motor circuit-breakers

Lighting Contactors. 6.1 Open Control. Product Overview...

Leadership driven by innovation

Motor Protection OLR. CEP7 Second Generation Solid State Overload Relays... B2 Technical Information... B8

Protectors. 35mm DIN rail snap-on mounting. Wide range of accessories

SIRCO PV UL98B Load break switches for photovoltaic applications from 100 to 2000 A - up to 1500 VDC

AF40... AF96 3-pole contactors Technical data

onlinecomponents.com

2 pole, 10 A power contacts 8 pin plug-in CO (DPDT) 3 CO (3PDT) Rated current/maximum peak current

Manual motor starter MS116

IDEC YC Contactors. New Contactors Now Available

Manual motor starter MS116

Enclosures. See Section Typical Description

Transcription:

Series C6 Contactors classic contactor for demanding applications from 75 to 600HP (@460V) - 100 to 700HP (@ 575V) This series is being replaced by the C9 Series of contactors Sprecher + Schuh s C6 contactor line combines the simple function of our popular C7 series with the rugged performance demanded in this middle horsepower range. On average these contactors are 50% smaller than traditional contactors in this size class. broad selection for middle horsepower applications The C6 range consists of nine contactors in three frame sizes covering motors from 75 to 600HP at 460V and from 100 to 700HP at 575V. This line is ideally suited for demanding applications such as steel mills, rock quarries, mines or for any middle horsepower application where a sturdy, durable contactor is needed. Rugged and reliable C6 contactors conform to UL508, IEC 60947 and can be operated at rated voltages up to 600V (UL) and 1000V (IEC). High thermal and switching capacities guarantee reliable operation and long life. C6 contactors are listed in CS Certified Elevator Equipment for heavy duty use in elevators, refrigerators and heating installations in Canada. rc quenching extends contact life ll C6 contactors are designed with sophisticated arc quenching techniques that extinguish damaging breaking arcs quickly. This is accomplished by guiding the arc away from the contacts and into arc chambers which are built-in to every C6 cover. Safety first C6 arc chambers are completely enclosed (without arc exhaust vents), offering the best protection against hot arcing gases. large safety distance in front of the contactor is unnecessary. C6 contactors are also designed so that operation is impossible if the arc chambers are removed. Conversely, once the contactor is energized, the arc chambers cannot be removed. When used with terminal covers or HB Touch-Safe Lugs, C6 contactors meet international standards for touch-safe design. 120mm ( 4 3/4 ) 115 120mm ( 4 3/4 ) 140 180 155mm ( 6 3/32 ) 210 250 300 420 215mm ( 8 15/32 ) 630 860 120

Electronic coils offer many advantages Behind the attractive outward appearance of the C6 contactor are advanced engineering solutions that offer convenience and savings. The entire line can be equipped with an electronically controlled coil that reduces pick-up currents by 60% on average. Holding current is also reduced. 2100 1800 1500 1200 900 600 300 0 Comparison of pick-up and holding current [V] Conventional Coil pick-up holding Electronic Coil Other advantages of the C6 electronic coil include: Direct connection to a PLC Overvoltage protection and suppression circuits (eliminating interference from the coil) are standard C6 EI electronic coils offer many unique advantages over conventional types Smooth, even operation over the entire voltage range minimizes the possibility of contact bounce No safeguards are necessary to bridge brief supply interruptions Precisely defined pick-up and dropout voltages, eliminate the possibility of chattering Electronic coils operate over a much broader voltage range, providing flexibility in applications and lower costs due to reduced inventory Two user-selectable modes C6 contactors with electronic coils operate in either the E mode for normal operation or the EI mode for interfacing directly with a Programmable Logic Controller (PLC) or other low level signal source (13...30.2 VDC). The coil is set in the E mode from the factory, offering all of the functions and advantages of an electronic coil with the exception of electronic interface. n orange jumper located on the bottom of the contactor can be quickly changed if interface from a PLC is desired. detailed technical explanation of EI coils along with connection diagrams can be found in the Technical Section. Jumper set in E mode (factory default) Jumper set in EI mode (user selectable) The entire C6 line is modularly designed for easy inspection, coil change and contact replacement. Maintenance can be performed from the front so that mounting requires no additional space. Even with the installation of mechanical interlocks and auxiliary contact blocks, the units can be flush mounted side by side, saving panel space. 10 3 4 6 7 9 6 7 9 1 115-EI Contactor 2 140-EI Contactor 3 Main Terminal Set 4 Lug set 5 Mechanical Interlock 6 ux. Contact Block 7 ux. Contact Block 8 ux. Contact Block 9 ux. Contact Block 10 Terminal Cover 11 Surge Suppressor 1 1 C6 contactors utilize modular design techniques that speed installation, reduce panel space and facilitate maintenance 5 2 5 11 2 11 8 8 121

Non-Reversing, Three Pole Contactors With C Coil, Series C6 (Open type only) ➊➌ Ratings for Switching C Motors (C2 / C3 ) uxiliary Open Type I e [] kw (50 Hz) UL/CS HP (60 Hz) Contacts per 1 Ø 3 Ø Contactor 400V/ C-3 C-1 230V 415V 500V 690V 115V 230V 200V 230V 460V 575V NO NC Catalog Number ➊➌ Price 115 250 37 64/66 80 111 10 25 40 40 75 100 1 1 140 250 45 78/82 80 ➍ 111 15 30 40 50 100 125 1 1 180 250 57 101/105 98 ➍ 135 ➍ ~ 40 50 60 150 150 1 1 115-11- 115-EI-11-140-11-140-EI-11-180-11-180-EI-11-669 805 1100 1250 1540 1750 Contactors - C Coil Three Pole - Series C6 140-EI contactor 210 350 67 118/122 147 205 ~ 50 60 75 150 200 1 1 210-EI-11-1850 250 350 80 140/145 177 250 ~ ~ 75 100 200 250 1 1 250-EI-11-2090 300 450 97 170/176 213 293 ~ ~ 100 125 250 300 1 1 300-EI-11-2330 420 540 135 238/250 298 424 ~ ~ 150 175 350 400 1 1 420-EI-11-4920 630 800 200 355 450 500 ~ ~ 200 250 500 600 1 1 630-EI-11-8770 860 1000 250 500 560 ~ ~ ~ 250 300 600 700 1 1 860-EI-11-11900 420-EI contactor Note: C6 open-type contactors include terminal bolts. If lugs are required, see page 129 for ordering information. Coil Codes ➋ C Coil Code 115 /140 /180 Voltage Range 50 Hz 60 Hz 24 ~ 24V 120B 110V 120V 208 ~ 208V 240B 220-230V 240V 277 240V 277V 380 380-400V 440V 480 415V 480V 575 500V 575V 115-EI...420-EI ➊ C Coil Code Voltage Range 50 Hz / 60 Hz 24 ➎ 24V 120 110-130V 220W 208-277V 460W 380-500V 630-EI...860-EI ➊ C Coil Code Voltage Range 50 Hz / 60 Hz 120 110-130V ➏ 208W 200-220V 240W 230-250V ➏ 277 277V 480 440-480V C6 EI coils are electronically controlled coils with the following characteristics: bility to connect directly to a low level signal source such as a PLC (13-30 VDC at 15m max.) Very low pull-in and holding current for contactors in this size class Threshold voltages for pull-in and drop-out are very precisely defined, eliminating chattering Supply voltage dips are bridged without extra equipment EI coils cover a much wider voltage range with only one coil Ordering Instructions Specify Catalog Number Replace ( ) with Coil Code See Coil Codes on this page ➊ -EI designates contactor with Electronic Interface coil. ➋ Other voltages available, see page 134-135. ➌ For CS Elevator duty rating, consult Technical Information on page 139. ➍ Ratings are higher for contactors with electronic coil: 140-EI-11-180-EI-11-500V = 98 kw 500V = 126 kw 690V = 135 kw 690V = 176 kw ➎ 24 VC Coil is not available for 420-EI. ➏ Coil is rated C/DC. 122 Discount Schedule B7

Non-Reversing, Three Pole Contactors With DC Coil, Series C6 (Open type only) ➊➌ Ratings for Switching C Motors (C2 / C3) uxiliary Open Type I e [] kw (50 Hz) UL/CS HP (60 Hz) Contacts per 1 Ø 3 Ø Contactor 400V/ C-3 C-1 230V 415V 500V 690V 115V 230V 200V 230V 460V 575V NO NC Catalog Number ➊➌ Price 115 250 37 64/66 80 111 10 25 40 40 75 100 1 140 250 45 78/82 80 ➍ 111 15 30 40 50 100 125 1 180 250 57 101/105 98 ➍ 135 ➍ ~ 40 50 60 150 150 1 1 1 1 1 1 1 115-L22-115-EI-11-140-L22-140-EI-11-180-L22-180-EI-11-210 350 67 118/122 147 205 ~ 50 60 75 150 200 1 1 210-EI-11-2290 807 920 1380 1560 1910 2190 Contactors - DC Coil Three Pole - Series C6 140-EI contactor with DC coil 250 350 80 140/145 177 250 ~ ~ 75 100 200 250 1 1 250-EI-11-2590 300 450 97 170/176 213 293 ~ ~ 100 125 250 300 1 1 300-EI-11-2920 420 540 135 238/250 298 424 ~ ~ 150 175 350 400 1 1 420-EI-11-6130 630 800 200 355 450 500 ~ ~ 200 250 500 600 1 1 630-EI-11-8770 860 1000 250 500 560 ~ ~ ~ 250 300 600 700 1 1 860-EI-11-11900 Note: C6 open-type contactors include terminal bolts. If lugs are required, see page 129 for ordering information. 420-EI contactor with DC coil Coil Codes ➋ 115 / 140 / 180 DC Voltage Range Coil Code 24D 24V 110D 110V 220D 220V Note: Conventional DC coils have high current pick-up winding and low current seal-in winding wired in parallel. The pick-up winding is taken out of the circuit after the armature pulls in. Price includes two winding coil and an L11 block including one NC late break auxiliary contact mounted on the right side. See page 149 for functional schematic. 115-El...420-EI ➊ DC Coil Code Voltage Range 24D ➎ 24V 120D 110-130V 220D 200-255V 630...860-EI ➊ DC Coil Code Voltage Range 120 110-130V ➏ 240W 200-255V ➏ C6 EI coils are electronically controlled coils with the following characteristics: bility to connect directly to a low level signal source such as a PLC (13-30 VDC at 15m max.) Very low pull-in and holding current for contactors in this size class Threshold voltages for pull-in and drop-out are very precisely defined, eliminating chattering Supply voltage dips are bridged without extra equipment EI coils cover a much wider voltage range with only one coil Ordering Instructions Specify Catalog Number Replace ( ) with Coil Code See Coil Codes on this page ➊ -EI designates contactor with Electronic Interface coil. ➋ Other voltages available, see page 134-135. ➌ For CS Elevator duty rating, consult Technical Information on page 139. ➍ Ratings are higher for contactors with electronic coil: 140-EI-11-180-EI-11-500V = 98 kw 500V = 126 kw 690V = 135 kw 690V = 176 kw ➎ 24V DC Coil not available for 420-EI. Customers selecting 24V DC Coils should consider the EI functionality of the C6 (see page 148). ➏ Coil is rated C/DC. Discount Schedule B7 123

Reversing, Three Pole Contactors With C Coil, Series C6 (Open type only) ➏ Ratings for Switching C Motors (C2 / C3) uxiliary Open Type I e [] kw (50 Hz) UL/CS HP (60 Hz) Contacts per 1 Ø 3 Ø Contactor 400V/ C-3 C-1 230V 415V 500V 690V 115V 230V 200V 230V 460V 575V NO NC Catalog Number ➊➌ Price 115 250 37 64/66 80 111 10 25 40 40 75 100 1 1 140 250 45 78/82 80 ➐ 111 15 30 40 50 100 125 1 1 180 250 57 101/105 98 ➐ 135 ➐ ~ 40 50 60 150 150 1 1 CU6-115-22- CU6-115-EI-22- CU6-140-22- CU6-140-EI-22- CU6-180-22- CU6-180-EI-22- Contactors, C Coil Reversing 18.90 2060 2710 3030 3600 4050 Three Pole - Series CU6 210 350 67 118/122 147 205 ~ 50 60 75 150 200 1 1 CU6-210-EI-22-4670 250 350 80 140/145 177 250 ~ ~ 75 100 200 250 1 1 CU6-250-EI-22-5150 300 450 97 170/176 213 293 ~ ~ 100 125 250 300 1 1 CU6-300-EI-22-5700 420 540 135 238/250 298 424 ~ ~ 150 175 350 400 1 1 CU6-420-EI-22-10800 630 800 200 355 450 500 ~ ~ 200 250 500 600 1 1 CU6-630-EI-22-19500 860 1000 250 500 560 ~ ~ ~ 250 300 600 700 1 1 CU6-860-EI-22-25800 CU6-180 reversing contactor Includes: Mechanical and electrical Interlock ➍ Reversing power wiring (using Power Wiring Kit Cat.# VL[T]) ➊ Mounting plate Control wiring available; see footnote ➋ Note: C6 open-type contactors include terminal bolts. If lugs are required, see page 129 for ordering information. Coil Codes ➋ C Coil Code 115 /140 180 Voltage Range 50 Hz 60 Hz 24 ~ 24V 120B 110V 120V 208 ~ 208V 240B 220-230V 240V 277 240V 277V 380 380-400V 440V 480 415V 480V 575 500V 575V ➊ For -LW Option Deduct the following from List Price CU6-115 180 175 CU6-210 860 360 ➋ For -CW Option dd the following to List Price ll CU6 20 Ordering Instructions Specify Catalog Number Replace ( ) with Coil Code 115-EI...420-EI ➊ C Coil Code Voltage Range 50 Hz / 60 Hz 24 ➑ 24V 120 110-130V 220W 208-277V 460W 380-500V 630-EI...860-EI ➊ C Coil Code Voltage Range 50 Hz / 60 Hz 120 110-130V ➒ 208W 200-220V 240W 230-250V ➒ 277 277V 480 440-480V See Coil Codes on this page C6 EI coils are electronically controlled coils with the following characteristics: bility to connect directly to a low level signal source such as a PLC (13-30 VDC at 15m max.) Very low pull-in and holding current for contactors in this size class Threshold voltages for pull-in and drop-out are very precisely defined, eliminating chattering Supply voltage dips are bridged without extra equipment EI coils cover a much wider voltage range with only one coil ➊ For Reversing Contactors without power wiring add suffix -LW to catalog number. For example: CU6-115-22- becomes CU6-115-22- -LW. Control wiring is not included. ➋ For control wiring, add suffix -CW to catalog number. For example: CU6-115-22- becomes CU6-115-22- -CW. ➌ -EI designates contactor with Electronic Interface coil. ➍ One NC auxiliary contact on each contactor is used for electrical interlocking. ➎ Other voltages available, see page 134-135. ➏ For CS Elevator duty rating, consult Technical Information on page 139. ➐ Ratings are higher for contactors with electronic coil: 140-EI-11-180-EI-11-500V = 98 kw 500V = 126 kw 690V = 135 kw 690V = 176 kw ➑ 24 VC Coil is not available for 420-EI. ➒ Coil is rated C/DC. 124 Discount Schedule B7

Reversing, Three Pole Contactors With DC Coil, Series C6 (Open type only) ➏ Ratings for Switching C Motors (C2 / C3) uxiliary Open Type I e [] kw (50 Hz) UL/CS HP (60 Hz) Contacts per 1 Ø 3 Ø Contactor 400V/ Catalog C-3 C-1 230V 415V 500V 690V 115V 230V 200V 230V 460V 575V NO NC➍ Number ➊➌➎ 115 250 37 64/66 80 111 10 25 40 40 75 100 140 250 45 78/82 80 ➐ 111 15 30 40 50 100 125 180 250 57 101/105 98 ➐ 135 ➐ 2 1 2 1 ~ 40 50 60 150 150 1 1 1 1 CU6-115-L42- CU6-115-EI-22- CU6-140-L42- CU6-140-EI-22- CU6-180-L42- CU6-180-EI-22-210 350 67 118/122 147 205 ~ 50 60 75 150 200 1 1 CU6-210-EI-22-5570 250 350 80 140/145 177 250 ~ ~ 75 100 200 250 1 1 CU6-250-EI-22-6170 300 450 97 170/176 213 293 ~ ~ 100 125 250 300 1 1 CU6-300-EI-22-6840 Contactors, DC Coil Reversing Price 2200 2420 3230 3640 4360 4910 420 540 135 238/250 298 424 ~ ~ 150 175 350 400 1 1 CU6-420-EI-22-13100 630 800 200 355 450 500 ~ ~ 200 250 500 600 1 1 CU6-630-EI-22-19500 860 1000 250 500 560 ~ ~ ~ 250 300 600 700 1 1 CU6-860-EI-22-25800 Three Pole - Series CU6 CU6-180 reversing contactor with DC coil Includes: DC operating mechanism Mechanical and electrical Interlock ➍ Reversing power wiring (using Power Wiring Kit Cat.# VL[T]) ➊ Mounting plate Control wiring available; see footnote ➋ Note: C6 open-type contactors include terminal bolts. If lugs are required, see page 129 for ordering information. Coil Codes ➎ 115 / 140 / 180 DC Coil Code Voltage Range 24D 24V 110D 110V 220D 220V Note: Conventional DC coils have high current pick-up winding and low current seal-in winding wired in parallel. The pick-up winding is taken out of the circuit after the armature pulls in. Price includes two winding coil and an L11 block including one NC late break auxiliary contact mounted on the right side. See page 149 for functional Ordering Instructions Specify Catalog Number Replace ( ) with Coil Code 115-EI...420-EI ➊➑ DC Coil Code Voltage Range 24D ➏ 24V 120D 110-130V 220D 200-255V 630...860-EI ➊➑ DC Coil Code Voltage Range 120 110-130V ➒ 240W 200-255V ➒ schematic. ➊ For -LW Option Deduct the following from List Price CU6-115 180 175 CU6-210 860 360 ➋ For -CW Option dd the following to List Price ll CU6 20 See Coil Codes on this page C6 EI coils are electronically controlled coils with the following characteristics: bility to connect directly to a low level signal source such as a PLC (13-30 VDC at 15m max.) Very low pull-in and holding current for contactors in this size class Threshold voltages for pull-in and drop-out are very precisely defined, eliminating chattering Supply voltage dips are bridged without extra equipment EI coils cover a much wider voltage range with only one coil ➊ For Reversing Contactors without power wiring add suffix -LW to catalog number. For example: CU6-115-22- becomes CU6-115-22- -LW. Control wiring is not included. ➋ For control wiring, add suffix -CW to catalog number. For example: CU6-115- 22- becomes CU6-115-22- -CW. ➌ -EI designates contactor with Electronic Interface coil. ➍ One NC auxiliary contact on each contactor is used for electrical interlocking. ➎ Other voltages available, see page 134-135. ➏ For CS Elevator duty rating, consult Technical Information on page 139. ➐ Ratings are higher for contactors with electronic coil: 140-EI-11-180-EI-11-500V = 98 kw 500V = 126 kw 690V = 135 kw 690V = 176 kw ➑ 24V DC Coil not available for 420-EI. Customers selecting 24V DC Coils should consider the EI functionality of the C6 (see page 148). ➒ Coil is rated C/DC Discount Schedule B7 125

Special Use Contactors - C Coil NEM Labeled Contactors - Series CN7 / CN6 Non-Reversing, Three Pole NEM Labeled Contactors with C Coil ➊➌ NEM Size 1Ø Maximum Horsepower 3Ø Standard uxiliary Contacts 115V 230V 200V 230V 460V 575V NO NC Catalog Number 00 1/3 1 1-1/2 1-1/2 2 2 1 0 CN7-12-10-0 1 2 3 3 5 5 1 0 CN7-16-10-1 2 3 7-1/2 7-1/2 10 10 1 0 CN7-37-10-2 3 7-1/2 10 15 25 25 1 0 CN7-43-10-3 7-1/2 15 25 30 50 50 1 0 CN7-85-10-4 ~ ~ 40 50 100 100 1 1 Price See page 42 CN6-180-11-2628 CN6-180-EI-11-3048 5 ~ ~ 75 100 200 200 1 1 CN6-300-EI-11-6529 CN6 NEM labeled contactor (C) pplication Notes NEM contactors are UL Listed and rated in accordance with the requirements of NEM standards publication ICS-2. These contactors are labeled for applications that require compliance with NEM standards. Sizes are based on standard NEM classifications. Easy coil change and contact replacement. See pages 134-135 for coils and contacts. Snap-on auxiliary contact blocks available in many configurations. See page 132 (C[N]6). Note: C6 open-type contactors include terminal bolts. If lugs are required, see page 129 for ordering information. CN6 C Coil Codes Conventional Coils ➋ CN6-180 C Coil Voltage Range Code 50 Hz 60 Hz 24 ~ 24V 120B 110V 120V 208 ~ 208V 240B 220-230V 240V 277 240V 277V 380 380V-400V 440V 480 415V 480V 575 500V 575V CN6 C Coil Codes EI Electronic Coils ➋➌ CN6-180-EI...300-EI C Coil Voltage Range Code 50 Hz / 60 Hz 24 24V 120 110-130V 220W 208-277V 460W 380-500V Ordering Instructions Specify Catalog Number Replace (Q) with Coil Code See Coil Codes on this page. ➊ Refer to page 154 for CN6 dimensions. ➋ Other voltages available, see pages 134-135 for CN6 coils. ➌ -EI designates contactor with Electronic Interface coil. 126 Discount Schedule B8

Special Use Contactors - DC Coil NEM Labeled Contactors - Series CN7 / CN6 Non-Reversing, Three Pole NEM Labeled Contactors with DC Coil ➊ NEM Size 1Ø Maximum Horsepower 3Ø Standard uxiliary Contacts 115V 230V 200V 230V 460V 575V NO NC Catalog Number 00 1/3 1 1-1/2 1-1/2 2 2 1 0 CN7-12E-10- ➎ 0 1 2 3 3 5 5 1 0 CN7-16E-10- ➎ 1 2 3 7-1/2 7-1/2 10 10 1 0 CN7-37E-10- ➎ 2 3 7-1/2 10 15 25 25 1 0 CN7-43E-10- ➎ 3 7-1/2 15 25 30 50 50 2 1 CN7-85D-10- Price See page 43 CN6 NEM labeled contactor 4 ~ ~ 40 50 100 100 1 1 CN6-180-L22- ➍ 2953 CN6-180-EI-11- ➌➍ 3048 5 ~ ~ 75 100 200 200 1 1 CN6-300-EI-11- ➌➍ 6529 pplication Notes NEM contactors are UL Listed and rated in accordance with the requirements of NEM standards publication ICS-2. These contactors are labeled for applications that require compliance with NEM standards. Sizes are based on standard NEM classifications. Easy coil change and contact replacement. See pages 134-135 for coils and contacts. Snap-on auxiliary contact blocks available in many configurations. See page 132. Note: C6 open-type contactors include terminal bolts. If lugs are required, see page 129 for ordering information. CN6 DC Coil Codes Conventional Coils ➋➍ CN6-180-L22 DC Coil Code Voltage Range 24D 24V CN6 DC Coil Codes EI Electronic Coils ➋➍ CN6-180-EI...300-EI DC Coil Code Voltage Range 24D 24V Ordering Instructions Specify Catalog Number Replace (Q) with Coil Code See Coil Codes on this page. ➊ Refer to page 154 for CN6 dimensions. ➋ Other voltages available, see pages 134-135 for CN6 coils. ➌ -EI designates contactor with Electronic Interface coil. ➍ Customers with 24VDC applications should strongly consider using the EI functionality of the C6 (see pages 148-149). Discount Schedule B8 127

Hydraulic Elevator Wye Delta, with C Coils (Two Contactor Type ➊➋➎) Maximum Horsepower Three Phase Industrial pplication ➎ CS Elevator Duty ➏ uxiliary Contacts per Contactor Open Type 200V 230V 460V 575V NO NC ➌ Catalog No. Price 60 60 125 150 C6Y2-115-22- -LW 1593 1 1 40 50 100 125 C6Y2-115-EI-22- -LW 1780 60 75 175 200 C6Y2-140-22- -LW 2483 1 1 50 60 125 125 C6Y2-140-EI-22- -LW 2803 75 100 200 250 C6Y2-180-22- -LW 3389 1 1 60 75 150 150 C6Y2-180-EI-22- -LW 3404 HP Selection Larger sizes are possible. Contact your Sprecher + Schuh representative. C6 EI coils are electronically controlled coils with the following characteristics: bility to connect directly to a low level signal source such as a PLC (13-30 VDC at 15m max.) Very low pull-in and holding current for contactors in this size class Threshold voltages for pull-in and drop-out are very precisely defined, eliminating chattering Supply voltage dips are bridged without extra equipment EI coils cover a much wider voltage range with only one coil Reduced Voltage Contactors Wye Delta - Series C6Y2 C6Y2-115 Wye-Delta contactor Includes: Mechanical and electrical Interlocks ➌ Mounting plate Optional: Power wiring available but not included (see page 130) ➊➐ 115 180-VYU 115 Coil Codes ➍ C Coil Code 115 180 Voltage Range 50 Hz 60 Hz 24 ~ 24V 120B 110V 120V 208 ~ 208V 240B 220-230V 240V 277 240V 277V 380 380-400V 440V 480 415V 480V 575 500V 575V 115-EI 180-EI ➊ C Coil Code Voltage Range 50 Hz / 60 Hz 24 24V 120 110-130V 220W 208-277V 440W 380-440V ➊ For -PW Option dd the following to List Price C6Y2-115 180 273 2M 180-VLHB S Ordering Instructions Specify Catalog Number Replace (Q) with Coil Code See Coil Codes on this page. ➊ For Contactors with power wiring add suffix -PW to catalog number. For example: C6Y2-115-22- -LW becomes C6Y2-115-22- -PW. Control wiring is not included. ➋ -EI designates contactor with Electronic Interface coil. ➌ One NC auxiliary contact on each contactor is used for electrical interlocking. ➍ Other voltages available, see page 134-135. ➎ HP selection based on UL508 for Industrial pplications. ➏ HP selection based on CS Elevator Duty Ratings. ➐ See typical Wye-Delta Wiring Diagram on page C117. 128 Discount Schedule B7

ccessories - Field Installable Main Lugs and Lug ccessories Lug or ccessory Connection Description Catalog Number Price Multiple conductors (flat or round) fit in each terminal on HB Main Terminal Sets (top view) ccommodation for dual connections to each pole ccepts flat or round conductors Touch safe to IP20 according to IEC 60529 Eliminates need for Terminal Shields Main Terminal Sets (catalog #: HB ) are specifically designed for connecting line and load to all three poles on C6 contactors. Each touch safe terminal set contains three built-in terminals capable of carrying two round conductors or multiple flat conductors. Main Terminal Sets add a clean finished appearance to C6 contactors Main Terminal Set, Dual Conductor, Touch Safe (price as complete set, containing 2 blocks, 6 lugs) For 115(-EI); 140(-EI); 180(-EI) For 210-EI to 420-EI HB2 HB3 125 188 Screw Type Lugs - Single connections to each pole ccepts round conductors only Copper construction (set of 3 - two sets required to wire line and load sides) For 115(-EI); 140(-EI); 180(-EI) For 210-EI to 420-EI L180 L420 82 179 Screw Type Lugs - ccommodation for dual connections to each pole ccepts round conductors only Copper construction (set of 3 - two sets required to wire line and load sides) For 630-EI L630 315 Screw Type Lugs - ccommodation for dual connections to each pole ccepts round conductors only Copper construction (set of 3 - two sets required to wire line and load sides) For 860-EI L860 456 (Typical) Control Wire Terminal ➊ 2 x 2.5mm 2 For 115(-EI); 140(-EI); 180(-EI) T1 5.26 For 210-EI to 420-EI T2 14.40 ➊ The IP2X lug rating will no longer apply if used with HB_ main terminal set. See Page 145 for terminal wire ranges. Discount Schedule B7 129

ccessories - Field Installable Power Wiring Connection Kits Connection Kits pplication Used with contactor... Use with Lug... Catalog Number Price 180-VLHB Reversing Line Side Wye-Delta Line Side Connects L1-L1 L2-L2 L3-L3 115(-EI) to 180(-EI) 115(-EI) to 180(-EI) 210-EI to 420-EI 630-EI to 860-EI L180 HB2 HB3 420-HU L420 L630 L860 180-VLHB 114 420-VLHB 274 860-VL 525 115(-EI) to 180(-EI) L180 180-VT 148 180-VT Reversing Load Side Connect T1-T3 T2-T2 T3-T1 115(-EI) to 180(-EI) HB2 180-VTHB 148 210-EI to 420-EI HB3 420-VTHB 276 210-EI to 420-EI 420-HU L420 420-VT 263 630-EI to 860-EI L860 860-VT 482 180-VYU Wye-Delta Shorting Bar 115(-EI) to 180(-EI) 210-EI to 420-EI N/ 180-VYU 420-VYU 14.90 30.30 630-EI to 860-EI N/ 860-VYU 59.70 Wye-Delta (2M to S jumper) Connects 2M contactor 210-EI to 420-EI... to S contactor C6140(-EI ) to 180(-EI) HB3 420-VYHB 234 420-VT Connects 2M contactor 210-EI to 420-EI... to S contactor 210-EI to 420-EI 420-HU L420 420-VT 263 130 Discount Schedule B7

ccessories - Field Installable Lug ccessories and Backpans ccessory Description Main Terminal Cover - ➊ C6 touch protection Line or load (price each) IP20; IEC60529 & DIN 40 050 protection For use with contactor... Catalog Number Price 115(-EI) to 180(-EI) 210-EI to 420-EI 630-EI to 860-EI 630-EI to 860-EI 630-EI to 860-EI 630-EI to 860-EI TC180 TC420 TC860 TCS860 ➋ TCR860 ➌ TCE860 ➍ 44.70 73.50 107 50.20 419 474 Mounting Plates 1 contactor & 1 O/L relay (cross- The-Line) 115(-EI)...180(-EI) 210-EI...420-EI 630-EI...860-EI MS180 MS420 MS860 61.20 98.60 247.00 2 contactors & 2 O/L relays (Reversing or Multispeed) 115(-EI)...180(-EI) 210-EI...420-EI 630-EI...860-EI MU180 MU420 MU860 98.60 148.00 300.00 3 contactors, 2 O/L relays & 1 relay/ timer (Wye-delta) For 115(-EI) to 180(-EI) For 210-EI to 420-EI 630-EI to 860-EI MY180 MY420 MY860 169 204 355 ➊ Terminal Covers not necessary when using Main Terminal Sets (HB ) which are insulated. ➋ DOL starter/relay terminal covers ➌ Reversing starter/relay terminal cover ➍ Line-side panel relay and reversing terminal cover Discount Schedule B7 131

ccessories - Field Installable uxiliary Contact Blocks, 2 Pole uxiliary Contact Blocks NO NC 1 1 1 1 Contact rrangement 13 44 14 43 53 84 54 21 32 22 31 61 72 62 Mounting Position Catalog Number Price Inside left or right S1-11 44.20 Outside left or right S2-11 44.50 NOTE: Up to four auxiliary contact blocks (8 poles) may be mounted on the side of the C6 contactor. One auxiliary contact block (1 NO + 1 NC) is mounted at the factory. New style 115 140 contactors with conventional DC coils have an -L11 mounted to right side and an -11 mounted to left side at the factory. 71 83 13 25 1 1 LB 44 14 36 26 Inside left or right S1-L11 51.50 35 43 13 23 2 0 53 44 14 43 34 24 33 63 Inside left or right S1-20 44.20 Inside left position (S1) Inside right position (S1) 2 0 84 54 83 74 64 73 Outside left or right S2-20 44.50 Outside left position (S2) Outside right position (S2) Form C Electronic Compatible 32 31 61 34 64 62 Inside left or right S1-B11 ➊ 73.50 Miscellaneous ccessories ccessory Description For use with... Catalog Number Price Mechanical Interlock- No built-in auxiliaries Interlocks C6 contactors CM6-D00 54.90 CM6-D00 Interlocks C6 to C7-60...97 contactors CM6-C02 65.80 Mechanical / Electrical Interlock - Two built-in N.C. auxiliaries CM6-D02 Interlocks C6 contactors CM6-D02 65.80 ➊ Electronic compatible auxiliary contacts function through the use of an internal micro-switch and have the following ratings: IEC 947 Data: C-1 250V 0.1 C-15/DC-13 min. 3 125V 1 100m UL 508, CS 22.2 Data: 250VC max. 0.1 Minimum Switching 17V 5m 132 Discount Schedule B7

ccessories - Field Installable Miscellaneous ccessories ccessory Description For use with... Catalog Number Price Surge Suppressor - Limits voltage spikes when switching off coil. ttaches to all C6 contactors. RC Link: 21-48V 50Hz. 24-55V 60Hz 95-110V 50 Hz / 110-127V 60 Hz 190-240V 50Hz / 220-277V 60Hz 380-550V 50Hz / 440-575V 60Hz Varistor Link: 12-55V 50/60Hz 56-136V 50/60Hz 137-277V 50/60Hz 278-575V 50/60Hz Varistor Link: 24-28V C/DC 48-72V DC 43-65V 50/60Hz 208-277 50/60 Hz 380-400V 50/60Hz Conventional C Coils Conventional C Coils Electronic (-EI) Coils ➊ CRC6-48 CRC6-110 CRC6-240 CRC6-550 CRV6-55 CRV6-136 CRV6-277 CRV6-575 CRV6-40 CRV6-55 CRV6-75 CRV6-550 CRV6-460 36.60 23.40 23.40 Marking Systems Component Description Pkg. Qty. Catalog Number Price Each Label Sheet - 1 sheet with 105 self-adhesive paper labels each, 6 x17mm 1 C7-FMS Marking Tag Sheet - 1 sheet with 160 perforated paper labels each, 6 x 17mm. To be used with transparent cover Transparent Cover - To be used with Marking Tag Sheets 1 C7-FMP 100 ➋ C7-FMC See page 54 Tag Carrier - For marking with marker cards and tags. See page N35 for complete listing of available cards and tabs. 100 ➋ C7-FM2 ➊ EI contactors are supplied with factory installed integrated surge protection (see page 135). ➋ Minimum order quantity is one package of 100. Price each x 100 = total price. Discount Schedule B7 133

Renewal Coils -.C., Conventional Coil ➊ C Control Voltages Conventional Coil C Coil Codes For use with contactor... 95, 110 115, 140 C(N)6-180 Optional RC Module ➋ Optional Varistor Module ➋ 50 Hz 60 Hz 50/60 Hz Catalog No. Catalog No. Catalog No. 24V ~ ~ 24 TG407 CRC6-48 CRV6-55 ~ 24V ~ 24 TG013 CRC6-48 CRV6-55 32V 36V ~ ~ TG481 CRC6-48 CRV6-55 42V 48V ~ 48 TG482 CRC6-48 CRV6-55 48V 55V ~ 48 TG414 CRC6-48 CRV6-55 110V 120V ~ 120B TG473 CRC6-110 CRV6-136 ~ 208V ~ 208 TG049 CRC6-240 CRV6-277 220-230V 240V ~ 240B TG441 CRC6-240 CRV6-277 240V 277V ~ 277 TG480 CRC6-240 CRV6-277 380V-400V 440V ~ 380 TG071 CRC6-880 CRV6-575 415V 480V ~ 480 TG475 CRC6-550 CRV6-575 440V 508V ~ ~ TG478 CRC6-550 CRV6-575 500V 575V ~ 575 TG479 CRC6-550 CRV6-575 550V 600V ~ 600 TG476 CRC6-550 CRV6-575 Price 178 See page 133 for pricing C6.C. Coil (typical) Renewal Coils Renewal Coils - D.C., Conventional Two-Winding Coil ➊➌ DC Control Voltages Conventional Coil DC Coil codes For use with contactor... 95 110 115, 140 C(N)6-180 Catalog No. Factory Integrated Varistor built into coil 12V 12D TG708 Yes 24V 24D TG714 Yes 48V 48D TG724 Yes 110V 110D TG733 Yes 125V 125D TG737 Yes 220V 220D TG761 Yes 240V ~ TG750 Yes 250V 250D TG751 Yes Price 248421 Items in grey are obsolete. ➊ Other coil voltages available. Contact your Sprecher + Schuh representative for information. ➋ Not factory installed, must be ordered separately. ➌ For conventional DC coils, the pickup winding must be connected to a NC late-break auxiliary contact. (See page 149) 134 Discount Schedule B6

Renewal Coils -.C., -EI Electronic Coil ➊➌➎ C Control Voltages EI Coil C Coil Codes ➋ 95-EI 110-EI 115-EI 140-EI 180-EI CN6-180-EI 210-EI 250-EI For use with contactor... 300-EI CN6-300-EI 420-EI 630-EI 860-EI EI Coil Suppressor Info Factory Integrated Suppressor on Coil Circuit Board ➌ Factory Installed External Suppressor Module ➌ 60 Hz 50/60 Hz Catalog No. Catalog No. Catalog No. Catalog No. Catalog No. ~ 24V 24 TGE855 TGE855 ~ ~ No CRV6-40 ~ 42-64V 48 TGE864 TGE864 ~ ~ No CRV6-75 ~ 110-130V 120 TGE865 TGE865 THE865 ~ Yes ~ ~ 208-277V 220W TGE866 TGE866 THE866 ~ Yes ➍ ~ 380-500V 460W TGE867 TGE867 THE867 ➑ ~ Yes RC 100N ➎ ~ 110-130V 120 ~ ~ ~ TJE865 ➏ Yes ~ ~ 200-220V 208W ~ ~ ~ TJE878 Yes ~ ~ 230-250V 240W ~ ~ ~ TJE879 ➏ Yes ~ ~ 277V 277 ~ ~ ~ TJE880 Yes ~ ~ 380-415V 380 ~ ~ ~ TJE867 Yes ~ ~ 440-480V 480 ~ ~ ~ TJE868 Yes ~ Price 421 421 565 882 Renewal Parts C6.C. -EI coil (typical) Renewal Coils - D.C., -EI Electronic Coil ➊➌➍ DC Control Voltage DC Coil Codes 95-EI 110-EI 115-EI 140-EI 180-EI CN6-180-EI 210-EI 250-EI For use with contactor... 300-EI CN6-300-EI 420-EI 630-EI 860-EI EI Coil Suppressor Info Factory Integrated Suppressor on Coil Circuit Board ➌ Factory Installed External Suppressor Module ➌ EI Coil Catalog No. Catalog No. Catalog No. Catalog No. Catalog No. 24V ➐ 24D TGE708 TGE708 ~ ~ No CRV6-40 48-72V 48D TGE779 TGE779 ~ ~ No CRV6-55 110-130V 120D TGE780 TGE780 THE780 ~ Yes ~ 200-255V 220D TGE781 TGE781 THE781 ~ Yes ~ 110-130 120 ~ ~ ~ TJE865 ➏ Yes ~ 200-255V 240W ~ ~ ~ TJE879 ➏ Yes ~ Price 494 636 636 882 Items in grey are obsolete. ➊ Other coil voltages available. Contact your Sprecher + Schuh representative for more information. ➋ Coil Codes in bold letters and shaded indicate coils that are standard stocked items. ➌ Factory external suppressor module provided where shown, included with replacement coil. ➍ Factory integrated suppressor is overvoltage category III, for optional category IV, e.g. lightning protection, a CRV6-550 module can be added. ➎ Special capacitor module supplied on 420 only, not shown in catalog. ➏ Coil is rated C / DC. ➐ Customers with 24VDC applications should strongly consider using the EI functionality of the C6 (see page 148). ➑ Contactor manufactured with 380-500V coils can not be interchanged with any other coils because of the circuit board built into the base of the 420. Discount Schedule B6 135

Main Contact - 3 Per Set (up to 420) Main Contacts (typical) For use with... Catalog Number Standard Terminal Hardware (screw & washer) ➊ Price/ Set 95 C95 250 95-EI CE95 296 110 C110 311 110-EI CE110 311 115 C115 296 115-EI CE115 296 140 C140 474 140-EI CE140 474 C(N)6-180 C180 565 C(N)6-180-EI CE180 589 210-EI CE210 763 250-EI CE250 956 C(N)6-300-EI CE300 1140 420-EI CE420 1640 Items in grey are obsolete and have limited availability. Renewal Parts Main Contact & rc Chute - Complete Set (630 and 860) Complete set of three each Main Contact, rc Chute and hardware For use with... Catalog Number Price/ Set 630-EI CE-630 ➍ 2940 860-EI CE-860 ➍ 3980 Terminal Hardware Fits Contactor... Screw Type Catalog Number Price Each 95 & 110 M6 HF110 27.70 115(-EI), 140(-EI) & C(N)6-180(-EI) 210-EI, 250-EI, C(N)6-300-EI & 420-EI M8 HF180 41.80 M10 HF420 84.80 rc Chutes ➋➌ rc Chutes (typical) 630-EI to 860-EI M12 HF860 128.00 Items in grey are obsolete and have limited availability. For use with... Catalog Number Price/ Set 95 95 124 95-EI E95 124 110 110 167 110-EI E110 167 115 115 160 115-EI E115 160 140 140 187 140-EI E140 206 C(N)6-180 180 244 C(N)6-180-EI E180 244 210-EI E210 456 250-EI E250 543 C(N)6-300-EI E300 634 420-EI E420 716 Items in grey are obsolete and have limited availability. ➊ Set of six (6). Priced per set. ➋ One (1) required per contactor. ➌ W rc Chutes available by special order. ➍ Kit includes Main Contacts and rc Chute Chamber. 136 Discount Schedule B6

Contactors Cross Reference, Series C1 & C6 to Series C9 (Open Type Only) ➊ Obsolete Contactor Cross Reference C1 or C6 to C9 Contactors Ratings for Switching C Motors (C2 / C3 / C4) Series C1 Series C6 Series C9 I e [] kw (50 Hz) UL/CS HP (60 Hz) Obsolete Obsolete Equivalent 400V / 1 Ø 3 Ø Catalog Catalog Catalog C-3 C-1 230V 415V 500V 690V 115V 230V 200V 230V 460V 575V Number Number Number 115 250 37 64/66 80 111 10 25 40 40 75 100 115 116 160 30 55 75 55 30 40 75 100 C9-116 10 25 40 40 75 100 C1-60 140 250 45 78/82 80 111 15 30 40 50 100 125 140 146 225 45 75 90 90 40 50 100 125 C9-146 15 30 50 50 100 125 C1-100 180 250 57 101/105 98 135 ~ 40 50 60 150 150 180 190 275 55 90 90 132 50 60 125 150 C9-190 ~ ~ 60 60 150 150 C1-150 205 350 55 110 110 160 60 75 150 200 C9-205 210 350 67 118/122 147 205 ~ 50 60 75 150 200 210 ~ ~ 75 100 200 250 C1-250 250 350 80 140/145 177 250 ~ ~ 75 100 200 250 250 265 400 75 132 160 200 75 100 200 250 C9-265 300 450 97 170/176 213 293 ~ ~ 100 125 250 300 300 305 500 90 160 200 250 100 125 250 300 C9-305 ~ ~ 150 150 350 400 C1-480 400 600 110 200/220 250 315 125 150 350 400 C9-400 420 500 135 238/250 298 424 ~ ~ 150 175 350 400 420 460 700 132 250 315 355 150 200 400 500 C9-460 580 800 160 315/355 400 500 200 250 500 600 C9-580 630 800 200 355 450 500 ~ ~ 200 250 500 600 630 750 1050 220 400/425 520 600 250 300 600 700 C9-750 860 1000 250 500 560 ~ ~ ~ 250 300 600 700 860 860 1350 257 475/500 560 800 ~ 400 800 1000 C9-860 C1-10 Contactor 140-EI contactor ➊ vailable auxiliary contacts may vary. See selection pages for more information. 137

Technical Information Technical Information Rated Insulation Voltage U i IEC, S, BS, SEV, VDE 0660 UL; CS [V] [V] 115(-EI) 140(-EI) 180(-EI) 210-EI 250-EI 1000V 600V 300-EI Rated Voltage U imp (kv) 12kV Rated Voltage U e - Main Contacts C 50/60Hz [V] 230, 240, 400, 415, 500, 690, 1000V DC [V] 24, 48, 110, 220, 440V Operating Frequency for C Loads [Hz] 50/60Hz 420-EI 630-EI 860-EI Switching Motor Loads Standard IEC Ratings C-2, C-3 230V [] 115 140 180 210 250 300 420 630 860 DOL & Reversing 240V [] 115 140 180 210 250 300 420 630 860 50Hz 400V [] 115 140 180 210 250 300 420 630 860 415V [] 115(130)➊ 140(155)➊ 180(189)➌ 210(227)➊ 250(258)➊ 300(315)➊ 420 630 860 500V [] 115 115/140➋ 140(180)➊ 210 250 300 420 630 753 690V [] 115 115/140➋ 140(180)➊ 210 250 300 420 492 ~ 1000V [] 46 55 65 80 95 115 160 ~ ~ 230V [kw] 37 45 57 67 80 97 135 200 250 240V [kw] 38 47 60 70 83 101 141 200 250 400V [kw] 64 78 101 118 140 170 238 355 500 415V [kw] 66(75)➊ 82(90)➊ 105(110)➊ 122(132)➊ 145(150)➊ 176(185)➊ 250 355 500 500V [kw] 80 80(98)➋ 98(126)➊ 147 177 213 298 450 560 600V [kw] 111 111/135➋ 135(176)➊ 205 250 293 424 500 ~ 1000V [kw] 63 75 90 110 132 160 225 ~ ~ UL/CS 115V [] 100 135 ~ ~ ~ ~ ~ ~ ~ DOL & Reversing 1 230V [] 110 136 176 216 ~ ~ ~ ~ ~ 60Hz 115 V [HP] 10 15 ~ ~ ~ ~ ~ ~ ~ 230 V [HP] 25 30 40 50 ~ ~ ~ ~ ~ 200V [] 120 120 150 177 221 285 414 552 692 230 V [] 104 130 154 192 248 312 420 602 720 460 V [] 96 124 180 180 240 302 414 590 702 3 575 V [] 99 125 144 192 242 289 382 562 651 200 V [HP] 40 40 50 60 75 100 150 200 250 230 V [HP] 40 50 60 75 100 125 175 250 300 460 V [HP] 75 100 150 150 200 250 350 500 600 575 V [HP] 100 125 150 200 250 300 400 600 700 C4 (200,000 Op. Cycles) 230V [] 53 60 67 85 105 140 170 ~ ~ 50Hz 240V [] 53 60 67 85 105 140 170 ~ ~ 400/415V [] 53 60 67 85 105 140 170 ~ ~ 500V [] 53 60 67 85 105 140 170 ~ ~ 690V [] 53 60 67 85 105 140 170 ~ ~ 1000V [] 25 37 43 60 72 85 105 ~ ~ 230V [kw] 15 17 20 25 32 45 55 ~ ~ 240V [kw] 15 18.5 22 25 32 45 55 ~ ~ 400/415V [kw] 25 32 37 45 / 50 55 75 /80 90 / 100 ~ ~ 500V [kw] 32 40 45 55 75 100 110 ~ ~ 690V [kw] 45 55 63 80 100 132 160 ~ ~ 1000V [kw] 30 50 55 80 100 110 150 ~ ~ Max. Operating Rate [ops/hr] 120 120 100 120 100 70 70 ~ ~ ➊ Values in ( ) represent ratings for C-2 & C-3 and result in reduced lifespan of 25%. Use 400V values for full life span. ➋ Second number is rating for the -EI model. 138

Electrical Data 115(-EI) 140(-EI) 180(-EI) 210-EI 250-EI 300-EI Technical Information 420-EI 630-EI Switching Motor Loads (continued) Wye-Delta (Star Delta) 230V [] 199 242 312 364 433 520 727 ~ ~ 50Hz 240V [] 199 242 312 364 433 520 727 ~ ~ 400V [] 199 242 312 364 433 520 727 ~ ~ 415V [] 199(225) 242(268)➊ 312(332) 364(393)➊ 433(447)➊ 520(546)➊ 727 ~ ~ 500V [] 199 199 / 242➋ 312 364 433 520 727 ~ ~ 690V [] 199 199 / 242➋ 312 364 433 520 727 ~ ~ 1000V [] 80 95 113 139 165 200 277 ~ ~ 230V [kw] 63 75 90 110 132 160 220 ~ ~ 240V [kw] 66 80 100 125 150 160 250 ~ ~ 400V [kw] 110 132 160 200 250 300 425 ~ ~ 415V [kw] 114(132)➊ 132(160)➊ 160 220 250 315(335)➊ 425➊ ~ ~ 500V [kw] 132 132 / 160➋ 200 250 315 375 530 ~ ~ 690V [kw] 192 200 / 220➋ 300 355 425 530 750 ~ ~ 1000V [kw] 100 132 160 200 220 280 400 ~ ~ 60 Hz 200V [HP] 60 60 75 100 125 175 250 ~ ~ 230V [HP] 60 75 100 125 175 200 250 ~ ~ 460V [HP] 125 175 200 250 350 450 600 ~ ~ 575V [HP] 150 200 250 300 450 500 650 ~ ~ UL/CS Elevator Duty 200V [] 78 92 120 150 150 177 221 ~ ~ 230V [] 80 104 130 130 154 192 248 ~ ~ 460V [] 77 96 124 156 180 180 240 ~ ~ 575V [] 77 77 99 125 144 192 242 ~ ~ 200V [HP] 25 30 40 50 50 60 75 ~ ~ 230V [HP] 30 40 50 50 60 75 100 ~ ~ 460V [HP] 60 75 100 125 150 150 200 ~ ~ 575V [HP] 75 75 100 125 150 200 250 ~ ~ C-1 Load, 3 Switching I th [] 250 250 250 350 350 450 540 800 1000 mbient Temperature 40 C 230V [kw] 100 100 100 139 139 179 199 319 398 240V [kw] 104 104 104 145 145 187 208 333 416 400V [kw] 173 173 173 242 242 312 346 554 693 415V [kw] 180 180 180 252 252 323 359 575 719 500V [kw] 217 217 217 303 303 390 433 693 866 690V [kw] 299 299 299 418 418 538 598 956 1195 1000V [kw] 433 433 433 606 606 779 866 ~ ~ mbient Temperature 60 C I th [] 210 210 210 300 300 380 425 ~ ~ 230V [kw] 84 84 84 120 120 151 169 ~ ~ 240V [kw] 87 87 87 125 125 158 177 ~ ~ 400V [kw] 145 145 145 208 208 263 294 ~ ~ 415V [kw] 151 151 151 216 216 273 305 ~ ~ 500V [kw] 182 182 182 260 260 329 368 ~ ~ 690V [kw] 251 251 251 359 359 454 508 ~ ~ 1000V [kw] 364 364 364 520 520 658 736 ~ ~ 860-EI ➊ Values in ( ) represent ratings for C3 & C4 and result in reduced lifespan of 25%. Use 400V values for full life span. ➋ Rating 140 / 140-EI. 139

Electrical Data 115(-EI) 140(-EI) 180(-EI) 210-EI 250-EI 300-EI 420-EI 630-EI Technical Information 860-EI Continuous Current (UL/CS) General Purpose Rating (40 C) Open [] 250 250 250 350 350 420 500 760 1000 Enclosed [] 220 220 220 300 300 340 420 630 860 Lighting Loads Elect.Dischrg.Lamps-C-5a, Open [] 144 225 225 315 315 405 450 ~ ~ single compensated Enclosed [] 122 189 189 270 270 342 383 ~ ~ Incandescent Lamps - C-5b [] 120 140 170 210 250 300 420 ~ ~ Switching power transformers C-6a Inrush Rated transformer current, P e n=30 240VC [] 60 70 85 105 125 150 210 ~ ~ 230 VC [kv] 24 28 34 42 50 60 84 ~ ~ 240 VC [kv] 26 29 35 44 52 62 87 ~ ~ 400 VC [kv] 42 48 59 73 87 104 145 ~ ~ 415 VC [kv] 43 50 61 75 90 108 151 ~ ~ 500 VC [kv] 52 61 74 91 108 130 182 ~ ~ 690 VC [kv] 72 84 102 125 149 179 251 ~ ~ 1000 VC [kv] 80 121 147 182 217 260 364 ~ ~ n = 20 690 VC [] 90 105 128 158 188 225 315 ~ ~ n = 15 690 VC [] 120 140 170 210 250 300 420 ~ ~ 60Hz Peak inrush/peak rated transformer n = 30 [] 60 70 85 105 125 150 210 ~ ~ 200V [kv] 20.8 24.2 29.4 36.4 43.3 52.0 72.7 ~ ~ 208V [kv] 21.6 25.2 30.6 37.8 45.0 54.0 75.7 ~ ~ 240V [kv] 24.9 29.1 35.3 43.6 52.0 62.4 87.3 ~ ~ 480V [kv] 49.9 58.2 70.7 87.3 104 125 175 ~ ~ 600V [kv] 62.4 72.7 88.3 109 130 156 218 ~ ~ 660V [kv] 68.6 80.0 97.2 120 143 171 240 ~ ~ 60Hz Peak inrush/peak rated transformer n = 20 [] 90 105 128 158 188 225 315 ~ ~ 200V [kv] 31.2 36.4 44.3 54.7 65.1 77.9 109 ~ ~ 208V [kv] 32.4 37.8 46.1 56.9 67.7 81.1 113 ~ ~ 240V [kv] 37.4 13.6 53.2 65.7 78.2 93.5 131 ~ ~ 480V [kv] 74.8 87.3 106 131 156 187 262 ~ ~ 600V [kv] 93.5 109 133 164 195 234 327 ~ ~ 660V [kv] 103 120 146 131 215 257 360 ~ ~ 60Hz Peak inrush/peak rated transformer n = 15 [] 120 140 170 210 250 300 420 ~ ~ 200V [kv] 41.6 48.5 58.9 72.7 86.6 104 145 ~ ~ 208V [kv] 43.2 50.4 61.2 75.7 90.1 108 151 ~ ~ 240V [kv] 49.9 58.2 70.7 87.3 104 125 175 ~ ~ 480V [kv] 99.8 116 141 175 208 249 349 ~ ~ 600V [kv] 125 145 177 218 260 312 436 ~ ~ 660V [kv] 137 160 194 240 286 343 480 ~ ~ 140

Electrical Data 115(-EI) 140(-EI) 180(-EI) 210-EI 250-EI 300-EI 420-EI Technical Information 630(EI DC Ratings DC-1 Rating at 60 C Non-inductive or slightly 24VDC [] 135 210 210 300 300 380 425 ~ ~ inductive loads, resistive 48VDC [] 135 210 210 300 300 380 425 ~ ~ furnaces 110VDC [] 135 210 210 300 300 380 425 ~ ~ 220VDC [] 3 3.3 3.3 4.9 4.9 4.9 5.2 ~ ~ 1 Pole 440VDC [] 0.6 0.75 0.75 1 1 1 1.2 ~ ~ 24VDC [] 135 210 210 300 300 380 425 ~ ~ 48VDC [] 135 210 210 300 300 380 425 ~ ~ 2 Poles in Series 110VDC [] 135 210 210 300 300 380 425 ~ ~ 220VDC [] 135 210 210 300 300 380 425 ~ ~ 440VDC [] 3 3.3 3.3 4.9 4.9 4.9 5.2 ~ ~ 24VDC [] 135 210 210 300 300 380 425 ~ ~ 48VDC [] 135 210 210 300 300 380 425 ~ ~ 3 Poles in Series ➊ 110VDC [] 135 210 210 300 300 380 425 ~ ~ 220VDC [] 135 210 210 300 300 380 425 ~ ~ 440VDC [] 11 11 11 14 14 14 15 ~ ~ 860-EI DC-3 Rating at 60 C Shunt wound motors - 24VDC [] 135 210 210 300 300 380 425 ~ ~ Starting, reverse current 48VDC [] 135 210 210 300 300 380 425 ~ ~ breaking, reversing, stepping 110VDC [] 135 210 210 300 300 380 425 ~ ~ 220VDC [] 135 210 210 300 300 380 425 ~ ~ 3 Poles in Series ➊ 440VDC [] 3 3.5 3.5 4.1 4.1 4.1 5.8 ~ ~ DC-5 Rating at 60 C Series wound motors - 24VDC [] 135 210 210 300 300 380 425 ~ ~ Starting, reverse current 48VDC [] 135 210 210 300 300 380 425 ~ ~ breaking, reversing, stepping 110VDC [] 135 210 210 300 300 380 425 ~ ~ 220VDC [] 135 210 210 300 300 380 425 ~ ~ 3 Poles in Series ➊ 440VDC [] 1.2 2.1 2.1 2.4 2.4 2.4 3.0 ~ ~ Three poles wired in series for DC switching + OPTION OPTION B ➊ See diagram to right for three poles wired in series for DC switching 141

Electrical Data 115(-EI) 140(-EI) 180(-EI) 210-EI 250-EI 300-EI 420-EI 630-EI Capacitor Ratings C-6b Capacitor Switching - 50Hz Single Capacitor - 40 C 230 V [kvar] 45 70 70 98 98 125 139 ~ ~ 240 V [kvar] 47 73 73 102 102 131 145 ~ ~ 400 V [kvar] 78 121 121 170 170 218 242 ~ ~ 415 V [kvar] 81 126 126 176 176 226 252 ~ ~ 500 V [kvar] 97 152 152 212 212 273 303 ~ ~ 690V [kvar] 134 209 209 293 293 376 418 ~ ~ 1000 V [kvar] 194 303 303 424 424 546 606 ~ ~ Single Capacitor - 60 C 230 V [kvar] 38 59 59 84 84 106 119 ~ ~ 240 V [kvar] 39 61 61 87 87 111 124 ~ ~ 400 V [kvar] 65 102 102 145 145 184 206 ~ ~ 415 V [kvar] 68 106 106 151 151 191 214 ~ ~ 500 V [kvar] 82 127 127 182 182 230 258 ~ ~ 690V [kvar] 113 176 176 251 251 318 356 ~ ~ 1000 V [kvar] 164 255 255 364 364 461 515 ~ ~ Capacitor Bank- 40 C 230 V [kvar] 45 70 70 98 98 125 139 ~ ~ 240 V [kvar] 47 73 73 102 102 131 145 ~ ~ 400 V [kvar] 56 76 111 170 170 218 242 ~ ~ 415 V [kvar] 56 76 112 170 176 226 252 ~ ~ 500 V [kvar] 56 76 113 172 212 273 303 ~ ~ 690V [kvar] 57 78 114 174 247 356 418 ~ ~ 1000 V [kvar] 58 79 116 177 251 361 606 ~ ~ Capacitor Bank- 60 C 230 V [kvar] 38 59 59 84 84 106 119 ~ ~ Capacitor Switching - 60Hz 240 V [kvar] 39 61 61 87 87 111 124 ~ ~ 400 V [kvar] 56 76 102 145 145 184 206 ~ ~ 415 V [kvar] 56 76 106 151 151 191 214 ~ ~ 500 V [kvar] 56 76 113 172 182 230 258 ~ ~ 690V [kvar] 57 78 114 174 247 318 356 ~ ~ 1000 V [kvar] 58 79 116 177 251 361 515 ~ ~ Single Capacitor - 40 C 200 V [kvar] 39 61 61 85 85 109 121 ~ ~ 230 V [kvar] 45 70 70 98 98 125 133 ~ ~ 460 V [kvar] 89 139 139 195 195 251 279 ~ ~ 600V [kvar] 116 182 182 255 255 327 364 ~ ~ Capacitor Bank- 40 C 200 V [kvar] 39 61 61 85 85 109 121 ~ ~ 230 V [kvar] 45 70 70 98 98 125 139 ~ ~ 460 V [kvar] 56 76 112 171 195 251 279 ~ ~ 600V [kvar] 57 77 114 173 246 327 364 ~ ~ Technical Information 860-EI 142

Technical Information Electrical Data Short-Circuit Coordination Contactors without Motor Protection Relays 115(-EI) 140(-EI) 180(-EI) 210-EI 250-EI 300-EI 420-EI 630-EI 860-EI DIn Fuses - gg, gl vailable Fault Current [] 100 K 100 K 100 K 100 K 100 K 100 K 100 K ~ ~ Type 1 [] 250 315 315(355) 500 500 630 630 ➊ ➊ Type 2 (380/400/415/690V) ➍ [] 200 250 250(315) 400 400 500 500 Type 2 (1000V) ➍ [] 200 250 250(315) 400 400 500 500 cul Short-Circuit Ratings Class K1, RK1, K5, and RK5 Fuses (L Fuses) vailable Fault Current [] 10 K 10 K 10 K 10 K 18 K 18 K 18 K 30 K 42 K cul Max. Rating (600V) ➌ Type 1 [] 250 350 450 500 L-700 L-700 L-1000 L-2000 L-2500 Class J CS & HRCI-J Fuses ➋ vailable Fault Current [] 100 K 100 K 100 K 100 K 100 K 100 K 100 K ~ ~ cul Max. Rating (600V) ➌ Type 2 [] 200 250 300 400 400 500 600 ~ ~ Circuit Breaker, inverse time ➎ vailable Fault Current [] 10 K 10 K 10 K 10 K 18 K 18 K 18 K 30 K 42 K cul Max. Rating (600V) ➌ Type 1 [] 150 200 250 300 350 400 500 1200 1200 Short Time Current Withstand Ratings l cw 60 C 1 S [] 1800 1800(2550) ➋ 2550 3405 3870 4725 6376 ➊ ➊ 4 S [] 1500 1800(1970) ➋ 1970 3150 3870 4100 6376 10 S [] 1040 1240(1360) ➋ 1480 2360 2520 2840 4700 6300 7000 15 S [] 860 860 (1130) ➋ 1130 2000 2110 2270 3460 60 S [] 650 650 (850) ➋ 850 1215 1300 1500 1880 ➊ ➊ 240 S [] 340 340 (600) ➋ 600 705 750 840 1280 900 S [] 240 250 (440) ➋ 440 460 500 590 840 Off Time Between Operations [Min.] 20 20 20 30 30 30 30 Resistance and Watt Loss I e C3 Resistance per power pole [mw] 0.4 0.42 0.42 0.22 0.22 0.18 0.15 0.19 0.14 Watt Loss - 3 power poles [W] 14.5 24.6 40.8 29.4 41.7 48.6 79.4 226.2 310.6 Coil and 3 power poles C [W] 24.5(20.5)➋ 34.6(30.6)➋ 50.8(46.8)➋ 35.4 47.7 54.6 86.5 256.2 340.6 (@I ec3) DC [W] 22.5(20.5)➋ 32.6(30.6)➋ 48.8(46.8)➋ 35.4 47.7 54.6 86.5 256.2 340.6 ➊ Under test. Contact your Sprecher + Schuh representative. ➋ Values in parentheses (_) are for the -EI- contactor. ➌ UL Listed Combination. (UL File E41850) Per UL508, NEC409 and CS 22.2 No.14 for contactor and fuses or circuit breaker only. ➍ Per IEC 60947-1 for contactor and fuses only. ➎ When used as a Branch Circuit Protection device, NEC 430-152 defines the maximum rating of an Inverse-time circuit breaker to be sized at 250% of the motor nameplate FL for most applications. 143

Short Circuit Ratings High Fault Short Circuit Ratings per UL508 and CS 22.2 No.14 CEP7 Second Generation Cat. No. CEP7 EEHF EEJF EEJG EEKG Contactor Catalog No. Max. starter FLC () Max. available fault current (k) Fuse Ratings Max. voltage (V) UL Class J and CS HRCI-J fuse () 115 115 CN6-115 100 600 200 140 140 250 180 CN6-180 180 100 600 300 210 210 400 250 250 100 600 400 300 CN6-300 300 500 210 210 400 250 250 100 600 400 300 CN6-300 300 500 EELG 420 420 100 600 600 Technical Information & Overload Relay UL Listed Circuit Breaker Ratings ➊ Short Circuit Rating (k) 65 25 65 25 65 30 65 30 42 25 Max. Voltage (V) 480 600 480 600 480 600 480 600 480 600 Max. CB rating () 250 250 400 400 600 ➊ Various Mfg. of UL Listed Circuit Breakers may be used. 144

Mechanical Data 115 115-EI 140(-EI) 180(-EI) 210-EI 250-EI Technical Information 300-EI 420-EI Service Life Mechanical C [Mil.] 10 10 10 10 10 10 10 10 2 2 DC [Mil.] 10 10 10 10 10 10 10 10 2 2 Electrical C-3 (400V) [Mil.] 1 1 1 1 1 1 1 1 R/F R/F Shipping Weights C - C6 [kg] 3.3 3.8 3.3 (3.8) 3.3 (3.8) 7.5 7.5 7.5 7.5 28.6 28.6 [Lbs] 7.3 8.38 7.3 (8.4) 7.3 (8.4) 16.5 16.5 16.5 16.5 63 63 DC - C6 [kg] 3.3 3.8 3.3 (3.8) 3.3 (3.8) 7.5 7.5 7.5 7.5 28.6 28.6 [Lbs] 7.28 8.38 7.3 (8.4) 7.3 (8.4) 16.5 16.5 16.5 16.5 63 63 Terminations - Power Type Direct Connection 630-EI Hexagonal Bolt b max. [mm] 25 30 52 860-EI c max. [mm] 12.5 15 22 s max. [mm] 5 6 2 x 8 Ø min. [mm] 8.3 10.5 13 Recommended Torque [Nm] 22 43 68 [Lb-in] 195 380 600 With Main Terminal Set (HB...) sm. opening [mm 2 ] 16...35 25...185 ~ lg. opening [mm 2 ] 16...95 25...185 ~ sm. opening [mm 2 ] 16...50 25...240 ~ lg. opening [mm 2 ] 16...120 25...240 ~ b max. [mm] 20 25 ~ s. sm. opening [mm] 3...9 6...20 ~ s. lg. opening [mm] 3...14 6...20 ~ Recommended Torque [Nm] 14 25 ~ Wire Size per UL/CS sm. opening [WG] #6...1 / 0 #4...600MCM ~ lg. opening [WG] #6...250MCM #4...600MCM ~ Recommended Torque [Lb-in] 124 220 ~ ➊ Minimum 25mm 2 (#4 WG) -95mm 2 (250mcm) with sleeve per DIN 46228. 145