C A M B E RTM PATENTS PENDING

Similar documents
TORNADOTM BOLLARD PATENTS PENDING

AerolumeTM. Collection. Area Luminaires 3 Fixture Sizes W HID 64/80/120

Light Nodes. Low Profile Surface Mounted Luminaires for LED Lamps. Patents Pending

LUM SERIES-PLED w/ POLE RATED FOR 100MPH SHAFT

A R C H I T E C T U R A L LO W L E V E L F LO O D L I G H T S E R I E S

1000 Watt Metal Halide Flood Light - 110,000 Lumens - Slipfitter Mount - 120~277 Volts AC

220/230/240V Watt High Pressure Sodium - Hazardous Location Lighting - C1D2 - Pole Mount

esconce mini esconce TM Architectural Area Lighting

Laredo Decorative Wallpack Family

WPP25 250W MP Wal-Pak Borosilicate Glass Hinged/Removabl


Height Finish Pole Options. Mounting Lamping Finish Voltage. Metal Halide. Single. H w H070 70w H w H w 15 1 /4" (387mm) 15 3 /4"

FCW3043 ADA FCW3045 ADA FCW3042 ADA FCW3040 ADA

LUMENTON. including poured concrete. Suitable for installation within 4 feet of ground. Product specifications subject to change without notice.

Overall Dimensions. Specifications

Laredo - Decorative Wallpack Family

LED LINEAR QUICK SUMMARY CO W SI MODEL CORTANA

SOURCE TE- Electronic MH. OPTIONS See Below OPTIONS. L = Lamped BLANK = General Purpose Optics A = Asymmetric Optics S = Spot

AFL FLOODLIGHT SERIES

SITE /ROADWAY BNS SERIES. Bounce. Pedestrian Scale Luminaire W H.I.D.

Applications. Standard Materials

Low brightness and uplighting combine to create a pleasing visual environment. Softbay Series

Pole Series. Series Reflector Lens Mounting Lamping Finish Voltage. S w S w S w S w

ORDERING INFORMATION: 120 Volts (120)

1000 Watt Metal Halide Light - Class 1 Division 2 Groups A-D - T3b Temperature - 110,000 lumens

ORDERING INFORMATION: 120 Volts (120) 208 Volts (208) 240 Volts (240) 277 Volts (277) 480 Volts (480)

EXPEDITED AVAILABILITY

IN-GRADE LTV SERIES. Lightvault NO COMPROMISES NO EXCUSES NO EQUALS BRONZE AND COMPOSITE HOUSING

Echo Shapes 9.0 LED. EEW in DESCRIPTION FEATURES & BENEFITS SPECIFICATIONS PROJECT DETAILS JOB NAME: TYPE: NOTES:

Overall Dimensions. Specifications

25 Sign / Wall Lighter 4324 LED Series Extruded Aluminum, PicoPrism LED revision 9/9/15 kl_4324led_series_spec.pdf

The ideal complement for commercial and retail spaces where users will appreciate classic interpretations of style and elegance. Kaleidoscope Series

TUBE. Precise construction encourages reliable IP rating. Bi-directional light output with single light source. Choices of light distribution angles.

GATEWAY ARCHITECTURAL LIGHTING APPEARANCE PERFORMANCE ENDURANCE

DECORATIVE. Tear Drop Series

LITON FLOOD / SPOT O U T D O O R A D J U S T A B L E L I G H T I N G

LytePro. A Family of Architectural LED Luminaires. Solid State, Solid Solutions. Stonco is a Philips company

FULL CUTOFF DARK SKY COMPLIANT FIXTURES. commercial & architectural lighting

3900 BOLLARD SERIES.

A r c h i t e c t u r a l A r e a L i g h t i n g

V-Bollard Architectural LED Luminaire / Bollard

CC/CCS21 21" Post Top Mounted, Curvilinear, LED revision 5/9/11 kim_cc21pled_spec.pdf

Post Top Globes. ACL Large Acorn Post Top Globe Page 109. ACS Small Acorn Post Top Globe Page 109

PGL350P W PS Wallpack

Project: Type: Qty: Height Lamping Finish Voltage Options. Series MTRQ /8" (1252mm) /16" (551mm) Options

ExceLine 1611 Clovis R. Barker Road San Marcos, TX Fax: PT#: EXSP072A0812

The PREMIER TM. II Series

Areamaster 100 Wide-Beam Floodlights 70 W, 100 W, 150 W HPS; 70 W, 100 W, 150 PSMH For general, marine and hazardous locations.

Induction Compact Fluorescent HID LPQ. Canopy Luminaire

Campana DETAILS CN55P1A. IP67 EPA: 1.8 FT 2 Weight: 52 lbs - 24 kg CN55P1B

Applications. Standard Materials. Certifications and Compliances

Visor Compact Architectural LED Wallpack. Technical Specifications VISOR TM. Visor Configuration Information. Project Catalog Number Type Date

Series Optics Mounting Lamping Finish Voltage. H039T6 1 39wT6 H w. H w. (T6 only available with MA and MS refractors) 12 3 /8" (314mm)

CEC: Class I, Division 1 and 2, Groups B, C, D Class II, Division 1 and 2, Groups E, F, G Class III Type 4X Exd IIB + H 2

Bavaria Downs. Chaska, MN. Lighting

INDEX PAGE WHERE LIGHT CREATES COLOUR SERIES, EDITION 01

U060 LIGHTWAY INDEX GRAZERS WASHERS AMBIENT

Perimaliter Wallpacks

HW, WA, WRSN and WRSM Series

CALLISTO SERIES. Product Overview and Technical information>>

Horizon Patient Bed Light LED and Fluorescent Solutions

A R C H I T E C T U R A L WA L L L U M I N A I R E S E R I E S

PGA Parking Garage Luminaire

PATHWAY LIGHTING 3100 SERIES LOUVERED BOLLARD

Lighting: Explosionproof Area HID. Applications. Standard Materials

LED STEP LIGHT LED Forms

CD20S2 DENVER. Luminaire. Optics. Sources Lamp 4K = High power LED, 4000K (neutral white) ±150K.

Nightscape High performance floodlights and spotlights for discharge lamps

V-Bollard Architectural LED Luminaire / Bollard

Beam Type Lamp Type Gear Type. Rated Input Power

Areamaster 1000 Floodlights Integrally Ballasted W HID For hazardous locations.

Lightruss Rail DESCRIPTION FEATURES & BENEFITS PROJECT DETAILS LRU Job Name: Type: Notes:

Quick Facts LED DIRECTIONAL FIXTURES

FLC131 LED + Linear spread lens IO

Vaporproof Strip - 4 Foot 1-3 Lamps

SITE /ROADWAY WARP9. The first outdoor luminaire designed not to be seen, using Visual Stealth Technology. TM

Dual Lamp Ceramic Metal Halide 3 Lumen Packages in 1 Luminaire

Promenade TM Series LED PRMD

VISA Bottom Detail (cutouts backed by white acrylic) Confetti (CNF) Solid (SLD) Slots (SLT) Windows (WIN)

Options. Pole and Arm. Suitable for wet locations

1400 Architura RGB Outdoor Linear LED

Saturn Cutoff. Order Code: Pole Order Code: Series Height Finish Options. Customer: Date: Project: Qty: Type: SAC Saturn Cutoff SAC

KAD250MR3TBSPD04 Wall Fixture

Meridian DETAILS CA10T4A CA10T4D CA13T4A. IP66 EPA: 2.2 FT 2 Weight: 27 lbs - 12 kg

IMPACT FLOODLIGHT Architectural Flood Luminaire

Contents A A L. 3 Scales 4 Spectra Indirect 6. Interior 8. Exterior 9. Arm Options-pole 10. Arm Options Wall 11. Construction 12.

ENERGY SAVING PRODUCTS LIGHTING

BOW SX - LED Luminaire

OP2 CosmoPolis Series

31 SERIES Modular area fixtures. Replaces: 1000W HID

Auto Dealership Solution

Taxonomies, Classifications, and Categories LED FLOODLIGHTS, WALLPACKS, BOLLARDS & LANDSCAPE LIGHTING

Perimaliter Wallpacks

Seem mm 4.50" 4.00" 101.6mm. Narrow 4" linear fluorescent allows for both individual or continuous runs.

LIGHTING: EXPLOSIONPROOF FLOODLIGHT. Applications. Options

Park Avenue DETAILS. IP67 EPA: 1.8 FT 2 Weight: 45 lbs - 20 kg

HID/AREA: NEC/CEC EXPLOSIONPROOF. Applications. NEC/CEC Certifications and Compliances

S43X. elliptipar high lumen. uplights S432 S431 S433 S434 PRODUCT

Quick Facts LED AREA LUMINAIRE

80 Watt Multi-Purpose LED Area Light

Transcription:

C A M B E RTM PATENTS PENDING

DAY CAMBER TM Camber is designed to be seen both day and night. Its daytime form is an eclectic blend of curvilinear and rectilinear lines accentuated by structurally expressive components. As such, Camber becomes an accent element for a broad range of contemporary architectural schemes. Camber is strongly three dimensional, casting interesting wall shadows and creating soft gradations on its own components. Camber will enhance any facade. 1 U.S.ARCHITECTURAL LTG. www.usaltg.com

NIGHT CAMBER TM Camber provides a unique array of functional and aesthetic illumination. Its primary light distribution is up and down, with the down light providing building perimeter and entrance illumination. The up light is for architectural features such as overhangs and projections. However, if upward light is not needed, Camber is available with fixed or adjustable indirect reflectors to redirect light downward. Camber also lights its surrounding wall, and its own surfaces, all with a fully shielded lamp to eliminate glare. www.usaltg.com U.S.ARCHITECTURAL LTG. 2

SELECTION GUIDE CBR1 CBR2 FORM Camber is an eclectic design consisting of curvilinear, rectilinear and structural components. It has a high degree of visual interest resulting from its functional expressiveness. Five Camber models are available, all building from the basic CBR1. As components are added in the CBR2,3,4 and 5, its visual dynamics increase, yet its function is always apparent. Camber is meant to be seen, and should be considered an accent element to the building, complementing the architecture with strong three dimensional forms in a contemporary design. FUNCTION Camber is a functional luminaire with each model offering unique lighting solutions. All Camber models illuminate their own components with soft glare free light, therefore rendering Camber a visible nighttime accent to the building. The functional aspects of Camber s illumination are down lighting for perimeters and entrances, up lighting for overhangs and projections, and wall illumination for visual accent. If color is desired, the CBR4 offers filters for a splash of upward color. SCALE Since Camber is designed to be an aesthetic and functional accent to the architecture, it has been sized to balance performance objectives with pedestrian scale. As such, its ideal mounting heights are 8 to 12. This also applies to interior spaces such as atriums, entrance halls and terminal buildings. 10.00" 254MM 24.00" 609.6MM 10.00" 254MM 12.50" 317.5MM 24.00" 609.6MM 14.00" 355.6MM 3 U.S.ARCHITECTURAL LTG. www.usaltg.com

CBR3 CBR4 CBR5 MAX. 13.5" 342.9MM 16.00" 406.4MM 12.50" 317.5MM 14.00" 355.6MM 10.50" 266.7MM 10.00" 254MM 24.00" 609.6MM 24.00" 609.6MM 24.00" 609.6MM www.usaltg.com U.S.ARCHITECTURAL LTG. 4

EXTERIOR / INTERIOR APPLICATIONS While Camber is primarily designed for exterior applications, its attributes are ideal for many interior spaces such as entrance halls, atriums, museums, terminals and interior shopping malls. These high ceiling spaces are ideal for Camber s ability to provide accent lighting on walls, ceilings, architectural features and floors. 5 U.S.ARCHITECTURAL LTG. www.usaltg.com

MECHANICAL / OPTICAL FEATURES INSTALLATION Camber engineering places strong emphasis on ease of installation and maintenance. The Ballast Housing is mounted to the wall independent of the Fixture. Four mounting holes are provided to secure the Ballast Housing to the wall as code requires for the wall type. (Mounting hardware by others). Caulking channels are also provided to seal the Ballast Housing/Wall interface. The Fixture Module can be mounted to the Ballast Housing at any time during construction. To free both hands for wiring, the Fixture Module hangs on slip hinges. Slip Hinge RELAMP Access to the glass lamp enclosure is accomplished by swinging open the Glare Shield. The fully gasketed lamp enclosure is unscrewed allowing the lamp to be replaced. At the same time, cleaning of the fixture exterior can readily be accomplished. OPTICAL CONTROL Camber s Glare Shield has been engineered to allow vertical adjustment. The factory preset is the centered position which provides approximately 45 degrees of lamp cutoff for both up and down light throw. If the Glare Shield is moved downward, the down light narrows while the up light broadens. The opposite happens when the Glare Shield is moved upward. Indirect reflectors are available to redirect upward light downward. The CBR2 is flat and fixed while the CBR3 is a subtle arc and adjustable. The main Glare Shield has vertical adjustment in five positions which controls up and down light spread and cutoff. Up light is not always desired unless there is something to illuminate. The fixed and adjustable indirect reflectors of the CBR2 and CBR3 will capture the up light and bounce it downward, adding to the ground plane illumination and providing additional fixture glow. www.usaltg.com The curved plane of the fixture always reflects light outward creating a soft glow to provide nighttime fixture presence. U.S.ARCHITECTURAL LTG. 6

SPECIFICATIONS MAX. 13.50" 342.9MM 16.00" 406.4MM 5.00" 127MM 3.00" 76.2MM 12.50" 317.5MM 10.00" 254MM CBR3 Indirect Reflector. Adjusts from 0º to 45º up. 14.00" 355.6MM 8.00" 203.2MM 17.50" 444.5MM 15.00" 381MM Wire entry is concaved to prevent water from entering ballast compartment. CBR2 and CBR4 Indirect Reflectors. CBR4 has color filter. See page 10. 24.00" 609.6MM Grooves are provided along back of the Ballast Housing perimeter for caulking to make housing watertight. Caulking provided by others. Four ½" dia. holes provided to secure ballast housing to wall. 3 /8" bolts required, bolts by others. Optional MR16 Emergency Egress fixture. Fully adjustable. BALLAST HOUSING (all models) Durable corrosion resistant, low copper cast aluminum alloy #A356 (<0.2% Cu) having four (4) 1/2 holes for mounting (3/8 bolts by others). A recessed channel allows for caulking to be applied and secured between the Ballast Housing and mounting surface. Ballast Housing mounts separate from Fixture Body and has integral cast hinges to accept stainlesssteel pins for mounting Fixture Body to Ballast Housing. Housing is always black. FIXTURE (all models) Durable corrosion resistant, low copper cast aluminum alloy #A356 (<0.2% Cu) with inset to index Body to Ballast Housing. Strut support arms are cast as integral components of the Fixture Body. Body mounts to Ballast Housing after Ballast Housing installation via cast hinges designed to accept stainlesssteel hinge pins. An integral socket cup has provision for threading and gasketing the lamp enclosure. A stainless steel recessed captive sockethead screw secures the Fixture Body to the Ballast Housing. STRUTS (Shield Support Arms) Struts are extruded aluminum.84 diameter. Struts are parallel and indexed to allow Glare Shield to be secured in one of five (5) vertical positions. One Strut has stainless steel recessed captive sockethead screws top and bottom to allow Glare Shield, Indirect Reflectors, or Half Cylinder to hinge away for relamping. LAMP ENCLOSURE One piece molded glass threads into cast aluminum socket cup. Socket cup is gasketed to prevent moisture or other contaminants from entering lamp compartment. SHIELDS AND REFLECTORS CBR1 (Glare Shield) Corrosion resistant aluminum construction. Shield has toolless hardware for indexing in one of five (5) positions (1 increments) along vertical Struts. CBR2 (Flat Indirect Reflector) Constructed of corrosion resistant low copper cast aluminum alloy #A356 (<0.2% Cu). Indirect reflector is flat and has stainless steel sockethead screws to secure its vertical position along the Struts. CBR3 (Curved Indirect Reflector) Constructed of corrosion resistant low copper cast aluminum alloy #A356 (<0.2% Cu). Indirect reflector is curved and has stainless steel sockethead screws to secure its vertical position along the Struts. Curved indirect reflector is adjustable for tilt from 0 (horizontal) to 45 up. CBR4 (Flat Indirect Reflector w/ Color Filter) Constructed of corrosion resistant low copper cast aluminum alloy #A356 (<0.2% Cu). Indirect reflector is flat and has stainless steel sockethead screws to secure its vertical position along the Struts. Indirect reflector has provision for mounting color filter. CBR5 (Full Cage Diffuser) Cage constructed of corrosion resistant low copper cast aluminum alloy #A356 (<0.2% Cu). Diffuser is mounted under cage and is opal white UV stabilized acrylic with minimum wall thickness of.125. 7 U.S.ARCHITECTURAL LTG. www.usaltg.com

LAMP / ELECTRICAL GUIDE LAMP WATTAGE LAMP TYPE SYSTEM WATTS BULB TYPE INITIAL LUMENS LIFE (HOURS) ANSI CODE STARTING TEMP. CIRCUIT TYPE VOLTAGE OPT. AMPS OPEN CIRCUIT AMPS STARTING AMPS MIN. FUSE AMPS PULSE START METAL HALIDE 50 PSMH 56 Clear, ED17, Med Base 4,100 10,000 M110 20 F Electronic 120 277 0.47 0.20 2 2 70 PSMH 80 Clear, ED17, Med Base Clear, T6, G12 Base 5,300 16,000 M98 M143 20 F Electronic 120 208 240 277 0.67 0.45 0.38 0.30 4 3 2 2 100 PSMH 129 Clear, ED17, Med Base 8,500 15,000 M90 M140 20 F Electronic 120 208 240 277 0.92 0.70 0.60 0.40 6 4 3 3 HIGH PRESSURE SODIUM 50 HPS Clear, ED17, Med Base 4,000 24,000 S68 40 F HPF 120 0.55 0.90 1.00 3 70 HPS Clear, ED17, Med Base 6,300 24,000 S62 40 F HPF 120 0.75 1.30 1.30 3 100 HPS Clear, ED17, Med Base 9,500 24,000 S54 40 F HPF 120 1.05 1.80 1.80 5 COMPACT FLUORESCENT 42 PL 46 Coated, GX24q4 Base 3,200 NOTE: 42W, 32W and 26W lamps use the same ballast. NOTES: 1 U.S. Architectural Lighting s Lamp and Electrical Guide is for reference only. ALWAYS consult lamp manufacturer s data for exact technical specifications. 2 All Initial Lumen values shown are approximate in the vertical position and may vary from one manufacturer to another. 3 All electrical data for Emergence Egress circuit is dependent upon power source. (see note #4) 4 Emergency Egress circuit is discreet for 12volt supply from generator, inverter, or battery backup. WARNING: All fixtures must be installed in accordance with local codes or the National Electrical Code. Failure to do so may result in serious personal injury. ELECTRICAL COMPONENTS All electrical components are UL recognized. High power factor ballasts are rigidly mounted inside the Fixture Body and are factory prewired with a quickdisconnect plug for mating to the socket. HPS core and coil ballast, reactor high power factor with starting temperatures of 40 F. MH electronic HID ballasts are high power factor, low frequency, 20 F starting. Fluorescent ballasts are electronic, high power factor, 0 F starting. HID socket is 4KV pulse rated medium base. Optional G12 base socket is available for 70PSMH T6 lamp mode. Fluorescent socket is universal for 26W, 32W, or 42W PL lamps. OPTIONAL EMERGENCY EGRESS Trilux Model TLXSF MR16 20W to 50W fully adjustable fixture rated for outdoor application. Discrete wiring circuit for connection to an emergency generator, inverter, or to battery backup (by others). (Refer to www.usaltg.com for detailed fixture specification) FINISH Electrostatically applied TGIC Polyester Powder Coat on substrate prepared with 20 PSI pressure power wash at 140 F.; four step iron phosphate pretreatment for protection and paint adhesion: baked at 400 F for maximum hardness and durability. GASKETS Between Ballast Housing and Fixture Body Onepiece continuous EPDM gasket with seam located on bottom edge of housing. Between Lens and Socket Cup Onepiece molded silicone gasket. U L wet location R U.L. Listed for IP65 www.usaltg.com U.S.ARCHITECTURAL LTG. 8

CBR1 Shield in center position Initial Horizontal Typical Half FC at Listed Mounting Heights Horizontal Distance in Units of Mounting Height 12 10 8 1 2 3 CBR1 Shield in lowest position Initial Horizontal Typical Half FC at Listed Mounting Heights Horizontal Distance in Units of Mounting Height 12 10 8 1 2 3 100W PMH 3.47 5 7.81 1.39 2 3.13.69 1 1.56.35.5.78 100W PMH 3.47 5 7.81 1.39 2 3.13.69 1 1.56.35.5.78.17.25.39.17.25.39.07.1.16.07.1.16 CBR1 Shield in center position Initial Horizontal Typical Half FC at Listed Mounting Heights Horizontal Distance in Units of Mounting Height 12 10 8 1 2 3 CBR2 Shield in center position Initial Horizontal Typical Half FC at Listed Mounting Heights Horizontal Distance in Units of Mounting Height 12 10 8 1 2 3 42 PL 1.39 2 3.13.69 1 1.56.35.5.78.17.25.39 100W PMH 3.47 5 7.81 1.39 2 3.13.69 1 1.56.35.5.78.07.1.16.17.25.39.07.1.16 CBR2 Shield in center position Initial Horizontal Typical Half FC at Listed Mounting Heights Horizontal Distance in Units of Mounting Height 12 10 8 1 2 3 45 EE Initial Horizontal Typical Half FC at Listed Mounting Heights Horizontal Distance in Units of Mounting Height 12 10 8 1 2 3 1.39 2 3.13 42 PL.69 1 1.56.35.5.78.17.25.39.07.1.16 50W MR16 FLOOD 3.47 5 7.81 1.39 2 3.13.69 1 1.56.35.5.78.17.25.39.07.1.16 CONVERSION FACTORS FOR OTHER LAMPS Multiply FC values by these factors FROM 50PMH 70PMH 100PMH 26PL 32PL 42PL 50HPS 70HPS 100HPS TO 50PMH 70PMH 100PMH 26PL 32PL 42PL 50HPS 70HPS 100HPS 0 0.77 0.48 2.28 1.71 1.28 1.03 0.65 0.43 1.29 0 0.62 2.94 2.21 1.66 1.33 0.84 0.56 2.07 1.60 0 4.72 3.54 2.66 2.13 1.35 0.89 0.44 0.34 0.21 0 0.75 0.56 0.45 0.29 0.19 0.59 0.45 0.28 1.33 0 0.75 0.60 0.38 0.25 0.78 0.6 0.38 1.78 1.33 0 0.80 0.51 0.34 0.98 0.75 0.47 2.22 1.67 1.25 0 0.63 0.42 1.54 1.19 0.74 3.50 2.63 1.97 1.58 0 0.66 2.32 1.79 1.12 5.28 3.96 2.97 2.38 1.51 0 9 U.S.ARCHITECTURAL LTG. www.usaltg.com

ORDERING INFORMATION Ordering Example CBR4 / 70PSMH120 / RAL9005 / CF15 / EE Fixture Electrical Mode Finish Option Option 1 2 3 4 5 1. FIXTURE CBR1 CBR2 CBR3 CBR4 CBR5 2. ELECTRICAL MODE PULSE START METAL HALIDE 50PSMH120 50PSMH277 HIGH PRESSURE SODIUM 70PSMH120 70PSMH208 70PSMH240 70PSMH277 70PSMH347 EXAMPLE LAMP WATTS 100 70PSMH120T6 70PSMH208T6 70PSMH240T6 70PSMH277T6 LAMP TYPE PSMH LINE VOLTS 277 100PSMH120 100PSMH208 100PSMH240 100PSMH277 100PSMH347 50HPS120 70HPS120 100HPS120 3. FINISH Electrostatically applied TGK powder coating features a multistep finishing process to produce a durable weather resistant finish. COLOR BLACK WHITE GREY DARK BRONZE GREEN TEXTURED RAL9005T RAL9003T RAL7004T RAL8019T RAL6005T SMOOTH RAL9005 RAL9003 RAL7004 RAL8019 RAL6005 COMPACT FLUORESCENT 42PL120 42PL208 42PL240 42PL277 NOTE: 42W, 32W and 26W lamps use the same ballast. PRODUCT IS AVAILABLE IN LED CONSULT FACTORY. NOTE: Other colors available. (Refer to www.usaltg.com/ralcolors.html) 4. COLOR FILTERS FOR CBR4 5. OPTIONAL EMERGENCY EGRESS Color Filters are for accent color on building overhangs, reliefs and projections. CLEAR DEEP STRAW 15 CFC CF15 MEDIUM RED 27 BRILLIANT BLUE 69 PRIMARY GREEN 91 CF27 CF69 CF91 CAT. NO. EE Trilux Model TLXSF 20W to 50W MR16 fixture for discrete wiring back to emergency generator, invertor or battery backup by others. NOTE: Other colors available. www.usaltg.com U.S.ARCHITECTURAL LTG. 10

CAMBERTM Product Design by Wayne Compton U.S. POLE COMPANY 660 West Avenue O Palmdale, California 93551 Toll Free (800) 8776537 www.usaltg.com