Liquid or convection cooled models available CAN bus serial interface

Similar documents
Typical efficiency up to 93 % Up to 4 kw power (max. 16 kw) Liquid or convection cooling. CAN bus serial interface. Adjustable output voltage

Very high efficiency up to 93% Adjustable output voltage

LDX-U20 is a microprocessor controlled DC-UPS rated 20 A usable in 12 V or 24 V systems.

150 WATT HEW SINGLE SERIES DC/DC CONVERTERS

DPX30-xxSxx DC-DC Converter Module 9.5 ~ 18 VDC and 18 ~ 36 VDC and 36~ 75 VDC input; 3.3 to 28 VDC Single Output; 30 Watts Output Power

DPX30-xxDxx DC-DC Converter Module 9.5 ~ 18 VDC and 18 ~ 36 VDC and 36~ 75 VDC input; ±12 to ±15 VDC Dual Output; 30 Watts Output Power

LDX-C120 Series is a 120 W integrated DIN Rail Battery Charger / DC UPS Power Supplies, suitable for wide variety of industrial applications.

DPX30-xxWSxx DC-DC Converter Module 10 ~ 40VDC, 18 ~ 75VDC input; 3.3 to 28VDC Single Output 30 Watts Output Power

LBC S102G 8000 W Ethernet CAN bus on request. LBC S101G W CAN bus Ethernet on request

DPX30-xxWDxx DC-DC Converter Module 10 ~ 40VDC, 18 ~ 75VDC input; ±12 to ±15 VDC Dual Output; 30 Watts Output Power

MODEL POWER BATTERY VOLTAGE COMMUNICATION. LBC SxxxG* 8000 W 110 V CAN or Ethernet. LBC SxxxG* W 110 V CAN or Ethernet

DPX15-xxWDxx Dual Output: DC-DC Converter Module 9.5 ~ 36VDC, 18 ~ 75VDC input; ±5 to ±15 VDC Dual Output; 15 Watts Output Power

HBC DC-DC Series Data Sheet 300-Watt Half-Brick Converters

HAE S 05 W - P HS Series Name Input Output Output Input Ctrl and Assembly Option Voltage Quantity Voltage Range Pin Options

Load (2) Single or Dual

Sixteenth brick format 4:1 input voltage range 2.25kV basic isolation Remote ON/OFF and trim pins UVLO, OTP, OVP, OCP and SCP Efficiency up to 91%

Features. Description. Table of Contents

HAE S 05 - P HS Series Name Input Output Output Ctrl and Assembly Option Voltage Quantity Voltage Pin Options

HAE S 05 W - P TH HS PART NUMBER STRUCTURE Page 1. P-DUKE Technology Co., Ltd.

WATT MBH SERIES DC/DC CONVERTERS

Output Current Input Current Over Load VDC VDC ma ma(typ.) ma(typ.) VDC μf %

HALF-BRICK DC-DC CONVERTERS 4:1 ULTRA WIDE INPUT RANGE 100 WATT RAILWAY APPLICATIONS HWB100 SERIES

Distributed power architectures Telecommunications equipment LAN/WAN applications Data processing Industrial applications

LANC245.1W12. DC/DC Converter VDC Input 5.1 VDC Output at 2.4A. Features:

HAE S 05 - P TH HS PART NUMBER STRUCTURE Page 1. P-DUKE Technology Co., Ltd.

Series AM2D-Z 2 Watt DC-DC Converter

Efficiency(1) Max. Capacitive. Package(3) CTRL Logic(2) Single

Series AM1P-Z 1 Watt DC-DC Converter

Package (3) CTRL Logic (2)

DSPS DSPS. Wide DC input. Switching Power Supply. Models: ESA-DS160 ESA-DS200. ESA-DS Ver.1.01 PAGE: 1 OF 7

2:1 Wide Input Voltage Range 1.6kVDC Isolation UL Certified Efficiency up to 91% Six-Sided Continuous Shield Available as Power Module (RPM60-G)

Series AM2S-Z 2 Watt DC-DC Converter

DC-DC CONVERTERS 2:1 INPUT RANGE, UP TO 2 WATTS MEDICAL APPLICATIONS MTWA2 SERIES

Input Voltage Continuous 0 80 VDC. Operating Ambient Temperature C Storage Temperature C. Operating Input Voltage Range VDC

IND065BLV Hornet: Non-Isolated DC-DC Voltage Regulator Modules

Isolated and rugged 24 Vdc power for battery powered electronic control systems on rail equipment

Note1: Efficiency is tested by nominal Vin, full load and at 25 C. Package (3) CTRL Logic (2)

Uninterruptible (ATX) Switching Power Supply. MODEL eups-350

MJWI20 SERIES FEATURES PRODUCT OVERVIEW. DC/DC Converter 20W, Highest Power Density MINMAX MJWI20 Series

North America Asia-Pacific Europe, Middle East

Delphi D12S Non-Isolated Point of Load

Series AM2D-Z 2 Watt DC-DC Converter

RP40- _FR/ Package (4) CTRL Logic (3)

PRELIMINARY. Ordering Part Numbers: Converter P/N: AX082600

Output Current Input Current Reflected Ripple. VDC VDC ma ma(typ.) ma(typ.) ma(typ.) VDC μf %

(typ.) (Range) Input Specifications Parameter Model Min. Typ. Max. Unit 12V Input Models Input Surge Voltage (100ms.

Notes: Note1: values at nominal input voltage and full load. 8.5VDC 5V 8V. Open, Efficiency vs. Input Voltage. Efficiency [%]

Switching Power Supplies

Note1: tested at nominal Vin, full load and at +25 C ambient. Package (3) CTRL Logic (2)

Telecommunications, Wireless, Servers, Workstations

Note1: Typical values at nominal input voltage and full load. 39VDC. Efficiency vs. Input Voltage. Efficiency [%]

Series AM2F-Z 2 Watt DC-DC Converter

Note1: Typical values at nominal input voltage and full load. 39VDC. Efficiency vs. Input Voltage. Efficiency [%]

American Power Design, Inc.

PARAMETER NOTES MIN TYP MAX UNITS. Input Voltage Continuous 0 40 VDC. Operating Ambient Temperature C. Storage Temperature C

American Power Design, Inc.

OSR03-24 S 05 A Series Name Input Output Output Assembly Voltage Quantity Voltage Option PART NUMBER STRUCTURE

Output Current Input Current Reflected Ripple. Efficiency (typ.) (Range) VDC VDC ma ma(typ.) ma(typ.) ma(typ.) VDC μf % MTQZ50-72S05

VDC VDC ma ma ma(typ.) ma(typ.) ma (typ.) VDC μf % MKW40-12S

1.5KW DC-DC Converter Specification

DORADO MV DC/DC CONVERTERS 24V Input 12VDC 8A Output

HALF-BRICK DC-DC CONVERTERS 4:1 ULTRA WIDE INPUT RANGE 150 WATT RAILWAY APPLICATIONS HWB150 SERIES

Output Current Input Current Reflected Ripple. Efficiency (typ.) Load VDC VDC ma ma ma(typ.) ma(typ.) ma (typ.) VDC μf % MKW40-12S033

CHASSIS MOUNT DC-DC CONVERTERS 4:1 WIDE INPUT RANGE, 150 WATTS RAILWAY APPLICATIONS FWB(D)150 SERIES*

4:1 Input Voltage Range 2.25kVDC Isolation UL Certified Efficiency up to 87% Ultraminiature Open Frame SMD No Minimum Load Required

RCD15W Series PART NUMBER STRUCTURE

C B. Operating up to 5000m altitude 5 year product warranty Models

BIDIRECTIONAL DC/DC CONVERTER

Model Number Output Voltage Output Amps Input Range Max. Iin FL Efficiency Max Output Power

Features. Regulated Converters. RP20-F 20 Watt 2 x 1 Single & Dual Output. RP20- _F/ Package 4) Control Logic (3) DC/DC Converter

Sorensen XG 1700 Series 1700 W A Watt, 1U Programmable DC Power Supplies V. Key Features. Key Modes

Output Current Input Current Reflected Ripple. Efficiency (typ.) Load VDC VDC ma ma ma(typ.) ma(typ.) ma (typ.) VDC μf % MKW40-12S033

Series AM1G-NZ 1 Watt DC-DC Converter

PDL09-48 S 05 M Series Name Input Output Output Case Voltage Quantity Voltage Option PART NUMBER STRUCTURE

PART NUMBER STRUCTURE. P-DUKE Technology Co., Ltd Page 1

(typ.) (Range) Load

DCMCW60 SERIES FEATURES

B70SR24125A/B/C/D 24V Output DC/DC Converter, Box Type Package

Series AM2D-RZ 2 Watt DC-DC Converter

S24SP15004 series 60W Single Output DC/DC Converter

POWERBOX Industrial Line PMF20W Series 20W 4:1 Single Output DC/DC Converter Manual. DC/DC Converter Features. Introduction

SL Series Application Notes. SL Series - Application Notes. General Application Notes. Wire Gage & Distance to Load

PG02S Series 2W DC/DC CONVERTER, SIP-Package

2:1 Wide Input Voltage Range 1.6kVDC Isolation UL Certified Efficiency up to 87% Low Profile, 10.2mm Height Over Current Protection

2018 Railway / Transit / Industrial RUGGEDIZED DC/DC CONVERTERS

S24SP series 40W Single Output DC/DC Converter

RDL06-48 S 05 W - M3 Series Name Input Output Output Input Operating ambient Voltage Quantity Voltage Range temperature PART NUMBER STRUCTURE

GB60S 60W Single Output General Purpose Series

Sorensen XG Series / XTR Series W A. 850 W, 1U Half Rack Programmable DC Power Supplies V

FW250R1 and FW300R1 Power Modules: dc-dc Converters: 36 Vdc to 75 Vdc Input, 28 Vdc Output; 250 W to 300 W

DH50 SERIES. DATASHEET Rev. A

RUZ- _/_ Protection (3) Isolation Option (4)

4:1 Wide Input Voltage Range 1.6kVDC Isolation UL Certified Efficiency up to 88% Six-Sided Continuous Shield Available as Power Module (RPM30-EW)

(typ.) (Range) ±18 330# 89 MPW MPW

RWS50B RWS100B RWS150B RWS300B RWS600B

Open Frame Power Supplies

QHW050F1, QHW075F1, and QHW100F1 Power Modules: dc-dc Converters; 36 to 75 Vdc Input, 3.3 Vdc Output; 33 W to 66 W

FEATURES. Input Voltage (VDC) 3.3

MPP10-48 S 05 W A - P T Series Name Input Output Output Input Pin Connection Remote On/Off Trim Voltage Quantity Voltage Range Option Options Option

Features. Figure 1. EFIL-28 Connection Diagram

Transcription:

The Bel Power Solutions 700DNC150-56-xG () is a 15000 Watts DC/DC converter that creates DC voltages in hybrid and electric vehicles necessary to power low voltage accessories. Attractive reverse energy flow is available in BDC models. Liquid or convection cooled DC/DC converter operates at input voltages from 630 to 770 VDC and power range up to 15 kw. Very high efficiency up to 96.5% Adjustable output voltage Input voltage range from 630 to 770 VDC Up to 15 kw power Over temperature, output overvoltage and overcurrent protection, input and output reverse polarity protection Full galvanic isolation between input and output Liquid or convection cooled models available CAN bus serial interface Protection degree IP67 North America +1-866-513-2839 Asia-Pacific +86-5-29885888 Europe, Middle East

MODEL INPUT VOLTAGE NOMINAL OUTPUT VOLTAGE INPUT CURRENT POWER RATING COOLING TYPE UNIT TYPE POWER FLOW 700DNC150-56-CG 700 V 56 V 265 A 15 kw Air Natural Convection Cooled Stand Alone Unidirectional 700DNC150-56-8G 700 V 56 V 265 A 15 kw Liquid Cooled Stand Alone Unidirectional 700BDC150-56-CG 700 V 56 V 265 A 15 kw Air Natural Convection Cooled Stand Alone Bidirectional 700BDC150-56-8G 700 V 56 V 265 A 15 kw Liquid Cooled Stand Alone Bidirectional Input Voltage 630 700 770 VDC HVDC Input Line Current @ 630 VDC 15.0 kw unit 23 ADC ELX Line Current Switched + Unswitched @ 12 V 2500 ma LVDC Line Current @ 56 V 15.0 kw unit 268 ADC Efficiency @ Vin = 700 VDC, Vo = 56 V, % Irated < Io_nom < Irated @ Vin = 700 VDC, Vo = 56 V, 50% Irated < Io_nom < % Irated @ Vin = 700 VDC, Vo = 56 V, 25% Irated < Io_nom < 50% Irated Input Line Interruption Converter shutdown 630 VDC Input Capacitance HVDC DC/DC Converter 8 μf HVDC Inrush Current External pre-charging circuit required 50 Apk 96 95 93 % Output Voltage Vo1 to be controlled via CAN BUS, 10bit resolution 48 56 57 VDC Output Current 268 268 263 ADC Output Power 12864 15000 15000 W Line Regulation Vin min - Vin max, at 134 A, Tcoolant = 70 C (liquid cooled) Tambient = 50 C (convection cooled) - 0.3 + 0.3 VDC Load Regulation Output voltage droop between 10 A and 268 A load, Tcoolant = 70 C (liquid cooled), +1.0 VDC Tambient = 50 C (convection cooled) Output Voltage Set Point @ 134 A, Tcoolant = 70 C (liquid cooled) Tambient = 50 C (convection cooled) -0.4% 56 +0.4% VDC Output Voltage Range Adjustable via CAN BUS 48.0 57.0 VDC Thermal Drift After 15 min warm up period -0.05 +0.05 %/ C Periodic and Random Deviation @ 56 VDC (Differential Mode) 1500 mvpk-pk 10 to 50 % and back Transient Response 50 to 100 % and back Voltage over/under shoot: -4000 +4000 mv Response time within 1 % of VoSET: 3000 μs Turn-on Overshoot Vonom, < 100 ms 1 % Redundant Parallel Operation Up to 4 converters operating in parallel 60 kw Remote Sense Cable Drop (V) @ Maximum Load 2 V Turn-On Delay Rise time (Cext = 0 μf) Power-on-delay (From applying DC input voltage to Vo = 90 %) Power-on-time from ELX Switched (From ELX Switched = High to Vo = 90% of nom) Turn-Off Timing ELX Switched delay (Vo Fall time must be monotonic) 0 100 ms Capacitive Load @ 56 VDC 0 100000 μf Up-conversion LVDC to HVDC LVDC clamping 2 s 400 1 800 ms s ms

Output Over-Current Protection Output Over-Voltage Protection If voltage drops below approximately 30 VDC for more 100 268 A than 1s, the output goes to hiccup mode Latch type, CAN Adjustable 48 57 V Max. OV duration 200 ms Output Under-Voltage Protection Max. UV duration 500 ms CAN Adjustable 48 57 V Over-Temperature Protection Input and Output Reverse Polarity Protection Current limit de-rating and Converter shutdown Protective elements connected in series Input Fuse Protection HVDC Input: internal primary fuse, safety approved 40 A Input Low Line Protection CAN Adjustable 500 780 V Input Overvoltage Protection CAN adjustable 500 780 V PARAMETER DESCRIPTION / CONDITION CAN BUS SAE J1939 500 kbit/s (250 kbit/s on request) Remote sense signals Sense positive Sense negative 2 V compensation Address bits Internally pulled up to LOGIC HIGH (3.3 V 100 kohm) Adr. 0 Adr. 1 ELX Switched (Enable) Logic input signal 9-36 VDC ELX Unswitched Supply of internal Bias converter 9-36 VDC HVIL function HVIL pin shorted internally Part of HV connector PARAMETER DESCRIPTION / CONDITION CRITERION Approvals Insulation Designed according IEC-61800-5-1 HVDC to Chassis Input to Output LVDC Power to Chassis Basic: 2000 VDC Reinforced: 3000 VDC or 2120 VAC Basic: 100 VDC Altitude Operating @ Tambient = 40 C 3500 5000 m Operating Temperature Air / Coolant -40 /-40 50 / 70 C Storage Temperature - 105 C Humidity SAE J14 Shock SAE J14 Vibration SAE J14, MIL-STD-202G PARAMETER DESCRIPTION / CONDITION MANUFACTURER MPN Input Connector (IN) High voltage connector TYCO HVA 630 variant A Output Connector (OUT) Two pole output terminals with M10 thread CAN BUS and Signal Interface (CTRL) Panel mounted TYCO 776276-1

Signal Connector Pin Description Signal Connector Output Connector (LVDC) Input Connector (HVCD) PIN NAME 1 DII1 Digital identification input / ADR0 2 ELV_GND 3 CAN shield 4 NC 5 Sense positive (+56V SENSE) 6 DII2 Digital identification input / ADR1 7 ELV_GND 8 CAN_H 9 NC 10 ELV Unswitched 11 ELV Switched 12 CAN_L 13 NC 14 Sense negative (-56V SENSE) Cooling Power Rating Power Conversion Convection (CG) / Liquid Cooled (8G) 7.5 kw (700DNC-56-CG, 700DNC-56-8G, 700BDC-56-CG, 700BDC-56-8G) 15 kw (700DNC150-56-CG, 700DNC150-56-8G, 700BDC150-56-CG, 700BDC150-56-8G) 22.5 kw (700DNC225-56-CG, 700DNC225-56-8G, 700BDC225-56-CG, 700BDC225-56-8G) Unidirectional (DNC), Bi-directional (BDC) MODEL MAX WEIGHT MECHANICAL DIMENSIONS 700DNC150-56-CG 700DNC150-56-8G 52 kg 43.5 kg 626 x 446 x 188 mm 626 x 446 x 122 mm Convection Cooled Model - Front View TYCO ELECTRONICS 1-776267-1 M8 OUTPUT TERMINALS TORQUE: 15Nm ±2Nm THREADED STUD 2x M10 TORQUE: 15Nm ±2Nm GORE VENT TYCO ELECTRONICS 8-2141272-1 2x M6 TORQUE: 7Nm ±0.7 Nm 174 ±1 188 VIBRATION DAMPER + WASHER 32.5 160 ±1 248.5 160 ±1 11 568.5 ±1 27.5

(Ø 8) Convection Cooled Model - Top View 20 446 ±1 HOT SURFACE LABEL HIGH VOLTAGE LABEL TERMINALS CAP BEL ITEM XKI.01199.0 PRODUCT LABEL 626 ±1.5 Convection Cooled Model - Side View 100 74 411 ±1

Mechanical Drawings Liquid Cooled Model - Front View TYCO ELECTRONICS 1-776267-1 M8 OUTPUT TERMINALS TORQUE: 15Nm ±2Nm THREADED STUD 2x M10 TORQUE: 15Nm ±2Nm GORE VENT TYCO ELECTRONICS 8-2141272-1 2x M6 TORQUE: 7Nm ±0.7 Nm 32.5 16 108 ±1 122 VIBRATION DAMPER + WASHER MALE STUD CONNECTOR THREAD 1-14UNS WITH O-RING 2x 378 120.6 11 160 ±1 248.5 160 ±1 27.5 568.5 ±1 Liquid Cooled Model Top View (Ø 8) 20 446 ±1 HOT SURFACE LABEL HIGH VOLTAGE LABEL TERMINALS CAP BEL ITEM XKI.01199.0 PRODUCT LABEL 626 ±1.5

Liquid Cooled Model Side View 34 74 411 ±1 NUCLEAR AND MEDICAL APPLICATIONS - Products are not designed or intended for use as critical components in life support systems, equipment used in hazardous environments, or nuclear control systems. TECHNICAL REVISIONS - The appearance of products, including safety agency certifications pictured on labels, may change depending on the date manufactured. Specifications are subject to change without notice.