Table Line and Load Terminals. Terminal Body Material. Wire Type. Aluminum Copper Aluminum. English English English.

Similar documents
Table Types LD, HLD and LDC Thermal-Magnetic Circuit Breakers with Interchangeable Trip Units

Courtesy of CMA/Flodyne/Hydradyne Motion Control Hydraulic Pneumatic Electrical Mechanical (800) RG H ZG E C

L-Frame LD F. Circuit Breaker/ Frame Ampere Rating. Trip Unit Rating/ Plug Ampere Rating LD T5 7 W

L-Frame. With Standard Line and. Standard Terminals Only. Catalog Number. Price U.S. $ LDB2300 LDB2350 LDB2400 LDB2450 LDB2500 LDB2600

Interchangeable Built-in Fixed thermal Adjustable thermal Magnetic Fixed Adjustable Adjustable Electronic RMS 7 LS LSI

2.2. Molded Case Circuit Breakers. Contents. NG-Frame ( Amperes) Series G

Product Line Overview. The Most Logically Designed Contact Assembly

Technical Data and Specifications. Table UL 489/IEC Interrupting Capacity Ratings. cu I cs I cu I cs I cu I cs I cu I cs I cu I cs

Molded Case Circuit Breakers Amperes LSIA. LSIG Catalog Number 3-Pole Standard Interrupting Capacity 600V AC Rated V AC 13,950.

Amperes. F-Frame. Price U.S. $ Catalog Number. Price U.S. $ EDH2100 EDH2125 EDH2150 EDH2175 EDH2200 EDH2225

Table Type FD Thermal-Magnetic Circuit Breakers with Non-interchangeable Trip Units

Poles 3 Starter Size NEMA 3 NON ALUMINUM LINE TERMINAL, LOAD TERMINAL

VL Circuit Breaker DG 150A frame

VL Circuit Breaker FG 250A frame Breaker type Defined by the 3rd character of the catalog number K Global, Non-interchangeable

Amperes. F-Frame. Price U.S. $ Catalog Number. Price U.S. $ EDH2100 EDH2125 EDH2150 EDH2175 EDH2200 EDH2225

Cutler-Hammer. January 2001

Cutler-Hammer Molded Case Circuit Breakers Amperes. January 2001 Vol. 1, Ref. No. [0477] G-Frame

Switchboards Instant Service

Tmax Molded Case Circuit Breakers

Product Line Overview. The Most Logically Designed Contact Assembly

Supplementary Protectors. Circuit Breakers & Circuit Breakers & Supplementary Protectors Contents

Series G Moulded Case. Circuit Breakers. Series G Moulded Case Circuit Breakers 1

2.3. Molded Case Circuit Breakers. Contents

Molded Case Circuit Breakers

3.1. Power Breakers, Contactors and Fuses. Contents. Series NRX Low Voltage Power Circuit Breakers. Power Circuit Breakers

SENTRON VL Series Product Specifications

Molded Case Circuit Breakers

25.4. Molded Case Circuit Breakers. For Immediate Delivery or Tech Support call KMParts.com at (866) Contents

Tmax Molded Case Circuit Breakers

30 ma Ground Fault (Earth Leakage) Modules. Product Description

Interrupting Capacity (Symmetrical Amperes) Volts ac (50/60 Hz) Y/ ,000 25,000. Frame Only E2L3600F

Page 2 DS LOW VOLTAGE POWER CIRCUIT BREAKERS Digitrip Trip Unit Inside Wiring Guide Outside Wiring Guide Shutter Drawout Unit Position Indicator Escut

The breakers offer thermal-magnetic trip protection according to Z and K characteristics.

Bulletin 140U R-Frame Molded Case Circuit Breakers

Molded Case Circuit Breakers

S4 N 250 B W - 2 xxx. Isomax. Isomax Molded case circuit breakers S3 S8. MCCBs

MCBs and accessories are certified under CSA C22.2 No. 235 per File LR Tripping characteristics

Miniature Circuit Breakers

Cutler-Hammer. Installation Instructions for the Digitrip OPTIM Pole Trip Unit Installation and Operation with L-Frame Series C Circuit Breakers

VL Circuit Breaker Features & Benefits. powerful ideas RELIABLE SOLUTIONS

Thermal-Magnetic For Mining Applications Class 600

Magnum IEC Low Voltage Air Circuit Breakers

24.4. Miniature Circuit Breakers and Supplementary Protectors. For Immediate Delivery or Tech Support call KMParts.com at (866)

APPENDIX E. Electrical System Single Line Diagram Overcurrent Protection Study Overcurrent Protection Device Specifications

Bussmann series Quik-Spec Power Module Switch elevator disconnect

Engine Generator Circuit Breakers

Cutler-Hammer. January 2001

Instruction Bulletin. DS/DSL and DSII/DSLII Low Voltage Power Circuit Breaker Replacement Parts Class 6035

GJL 100 A Molded Case Circuit Breaker GJL 75 A Motor Circuit Protector

Panelboards and Lighting Control. Types PRL1a, 2a, 3a, 3E, 4 and Column Modifications. Contents Description

Molded Case. Circuit Breakers. Molded Case Circuit Breakers Contents

Molded Case Circuit Breakers

Metal-Enclosed Switches. Medium Voltage. Medium Voltage Metal-Enclosed Switches Contents

CH120CAFPN 1P 20A 120 Combo Arc Fault PN Breaker

Control Circuit Protection

F-Series. Circuit Breaker

Cutler-Hammer. Molded Case Circuit Breakers Amperes F-Frame. January 2001

F-Series. Circuit Breaker

Medium Voltage Metal-Enclosed Switches

Series G Moulded Case Circuit Breakers A for IEC & NEMA Applications

Type MP-T Type MP-HT Type MP-MT

Magnum IEC Air Circuit Breakers Price List All Prices in US$ for Export Sale

TYPES DS II AND DSL II METAL ENCLOSED LOW VOLTAGE POWER CIRCUIT BREAKERS

PRICING. Multi 9, Compact, Masterpact, Interpact, and Vigirex Circuit Protection Products. Class 600. October 2004

Industrial Generator Set Accessories. Standard Features. Line Circuit Breakers kw

C E R T I F I C A T E O F C O M P L I A N C E

Series KTU7 UL489 Molded Case Circuit Breakers

Application guide. Tmax Link OEM UL 891 Switchboard Program

Selection and Application Guide Supplement. WL UL Pole Circuit Breakers. usa.siemens.com/wlbreaker

Cutler-Hammer. Molded Case Circuit Breakers Amperes January J-Frame

Modifications. Marine 50 C Ambient Calibration

DRX 100 B/N/H Circuit breaker (not adjustable)

Series C, F-frame molded case circuit breaker, 15A, Two-pole, Thermal Magnetic Trip, FD Breaker

Cutler-Hammer. Molded Case Circuit Breakers Amperes. -" Product Selection M-Frame

DMX 3 -I 2500 switch disconnectors

Manual motor protectors Type MS116 Type MS325 Type MS45X Type MS49X

S200-C, 480Y/277 VAC Supplemental protectors UL 1077, CSA 22.2

Magnum DS, SB and IEC low voltage power circuit breakers Technical product guide

Lighting and Power Distribution Panelboards

S4 N 250 B W - 2 xxx. Isomax MCCBs. Isomax Molded case circuit breakers S1 S8

MS General Information Extended Product Type: MS

Series C, F-frame molded case circuit breaker, 125A, Three-pole, Thermal magnetic trip. Thermal magnetic

UTS400 SELECTION GUIDE CATALOG NUMBERING [PRODUCT SELECTION] UTS400 NT ATU 400A 3P LL LSIS UL MCCB

Cutler-Hammer. Molded Case Circuit Breakers Amperes. Product Selection January 2001 Vol. 1, Ref. No ) J-Frame

Modifications. Marine 50 C Ambient Calibration

Section SWITCHBOARDS. Introduction. Part 1 - General. Related Work

PowerPact M-, P- and R-Frame, and Compact NS630b NS3200 Circuit Breakers

Fusetron FRN-R Class RK5 250Vac/125Vdc A, dual element, time-delay fuses

S200 UL 1077 Series S200. Supplementary protective devices. UL 1077 Series. Miniature. circuit breakers. S200 Supplementary protective devices

Section 3: Molded Case Circuit Breakers

UMBW-UL489 and UL1077 Listed

Molded Case Circuit Breakers

Manual motor protectors Type MS116 Type MS325 Type MS45X Type MS49X

Modular Metering - Trip Unit for >1200A Mains DEH41187 Application Guide

DRX 250 B/N/H Circuit breaker (not adjustable)

Cutler-Hammer I.L. 29C160G WARNING NOTICE 1-0 INTRODUCTION. General Information

Preliminary AC1615S. ABB Molded Case Circuit Breakers

2.3. Molded Case Circuit Breakers. Contents. Internal Accessories. Series C. Product Overview. Description

Magnum IEC Low Voltage Air Circuit Breakers

Installation Instructions for JDB, JD, HJD, JDC, JW HJW, JWC Circuit Breakers and Molded Case Switches

Transcription:

-174 Series C Molded Case Circuit s July 7 Molded Case Switches Refer to Eaton for UL listed, series tested Molded Case Switch application data. Table -278. Molded Case Switches Cont. Amp Rating at 40 C Complete without Terminals 3-Pole 4-Pole Note: Molded case switch may trip above 17,0 amperes. Line and Load Terminals Line and Load Terminals provide wire connecting capabilities for specific ranges of continuous current ratings and wire types. All terminals comply with Underwriters Laboratories Standards UL 486A and UL 486B and CSA C22.2 No. M. Unless otherwise specified, circuit breaker line load terminals are shipped separately for field installation. Ordering Information High Instantaneous (K) 1600 316WK 416WK High Instantaneous (K) 320WK 420WK circuit breakers have Cu/AI terminals as standard and Cu only terminals as an option. Specify if factory installation is required. Table -279. Line and Load Terminals Maximum Amperes Wire Terminals 1600 1600 Rear Connectors 20 Terminal Body Material Aluminum Aluminum Wire Cu/AI Cu Cu/AI Hardware AWG/kcmil Wire Range/ No. Conductors 0 0 (4) 1 600 (4) 2 600 (6) Metric Wire Range mm 2 300 0 300 35 300 TA1600 T1600 TA includes bus connection, terminals and hardware for either line side or load side of 3-pole breaker. For use with % rated 1600 A and A frame. Do not order separately unless for replacement purposes. Included in breaker carton when % rated device is ordered. For use with 20 A frame. Do not order separately unless for replacement purposes. Included in breaker carton when 20 A breaker is ordered. Line/Load Conductors B2016 B2016L B20 TA Figure -39. Mounting Hardware Rear Connector (Cu) B2016 B2016L (For % Appl. (For 1600 A & A Frames) B20 (For 20 A Frame) Figure -40. Mounting Hardware Discount Symbol........................ CB-2 CA08101E

Series G Molded Case Circuit s Frame Size RG, 20 Amperes ka at 480 Vac, 70 ka at 415 Vac Digitrip 310 Trip Unit -47 Product Selection Table -79. Circuit /Frame ing System RGH 3 16 T33 W A01 RGH K RGC K Amperes 16 = 1600 A 20 = A 25 = 20 A 3 = 3 Poles 4 = 4 Poles Trip Function Digitrip 310 T33 = LS T32 = LSI T35 = LSG T36 = LSIG Digitrip 610 T61 = LI T62 = LSI T63 = LS T64 = LIG T = LSG T66 = LSIG Digitrip 910 T91 = LI T92 = LSI T93 = LS T94 = LIG T95 = LSG T96 = LSIG R E P Modification Suffix = Ground Fault Remote RES Trip = % Protection (New Design 310) RES Trip Unit = % Prot. Neut. 4P RES Trip Unit V3 = Electronic Trip w/o Ambient Temperature Marked on Trip Unit W = w/o Terms K = Molded Case Switch Function Codes A-A19 = Auxiliary Switch B01-B02 = Bell Alarm D01 = Drawout Moving Carrier E01-E13 = Electrical Operator H01-H11 = Special Ratings J01 = Moisture Fungus Proof L01-L05 = Locks N01 = Low Energy Shunt Trip P01-P64 = Rating Plugs Q01-Q02 = Terminal Block S21-S88 = Shunt Trip T21-T37 = UVR (DC) U33-U58 = UVR (AC) W01 = Walking Beam Interlock X01-X08 = Load Termination Y01-Y08 = Line Termination Z01-Z08 = Line & Load Termination Dimensions/Weights Table -80. Dimensions in Inches (mm) 3 4 Width Height Depth 15. (393.7) 20.00 (8.0) Table -81. Approximate Shipping Weight, Lbs. (kg) Complete 3 4 1600 Amperes RGH, RGC 102 (46.3) 135 (61.2) Amperes RGH, RGC 102 (46.3) 135 (61.2) 20 Amperes RGH, RGC 135 (61.2) 182 (82.6) CA08101E

Typical Circuit Product Description Cutler-Hammer Circuit s by Eaton Corporation are available as frame (which includes trip unit), rating plug and terminals. All circuit breakers are suitable for reverse feed use. Series C Molded Case Circuit s Technical Data and Specifications Table -248. UL 489/CSA Interrupting Capacity Ratings Circuit C C Utilization Category A circuit breakers. % rated breakers. Note: See Page -158 for Trip Unit Specifications. Table -249. IEC 947-2 Interrupting Capacity Ratings Circuit I cu I cs I cu I cs Utilization Category A circuit breakers. Interrupting Capacity (ka Symmetrical Amperes) Volts ac (/60 Hz) 240 277 480 600 5 5 Interrupting Capacity (ka Symmetrical Amperes) Volts ac (/60 Hz) 240 415 690 135 70 25 13 35 18-157 CA08101E

Series C Molded Case Circuit s -159 Dimensions/Weights Table -251. Dimensions in Inches (mm) 3 4 Width Height Depth 15. (393.7) 20.00 (8.0) Table -252. Approximate Shipping Weight, Lbs. (kg) Complete 3 4 1600 Amperes, C,, C 102 (46.3) 135 (61.2) Amperes, 102 (46.3) 135 (61.2) C, C 130 (59.0) 175 (79.4) 20 Amperes, 135 (61.2) 182 (82.6) Product Selection This information is presented only as an aid to understanding catalog numbers. It is not to be used to build catalog numbers for circuit breakers or trip units. Table -253. Circuit /Frame ing System 3 16 T32 W Circuit / Frame C C 3 = 3 Poles 4 = 4 Poles Circuit / Frame Ampere Rating 16 = 1600 Amperes 20 = Amperes 25 = 20 Amperes Trip T32 = Digitrip RMS 310 LSI T53 = Digitrip RMS 510 LS T = Digitrip RMS 610 LSG T86 = Digitrip RMS 810 LSIG T96 = Digitrip RMS 910 LSIG T106 = Digitrip OPTIM 10 LSIG T107 = Digitrip OPTIM 10 LSIA Suffix W = Without Terminals P = % Protected Neutral Pole R = Ground Fault Remote (310 Only) K = Molded Case Switch For complete list of available trip types refer to Pages -160-173. CA08101E

Series C Molded Case Circuit s Internal Accessories Undervoltage Release Mechanism -253 Table -486. Undervoltage Release Mechanism (RH only) Voltage Rating (ac Frequency = /60 Hz) Vac 24 Vac 48 60 Vac 110 7 Vac 208 240 Vac 380 0 Vac Vdc 24 Vdc 48 60 Vdc 110 5 Vdc 220 2 Vdc Factory Mounted Connection and Location 18-Inch (457.2 mm) Pigtail Leads Suffix U37 U41 U45 U49 U53 U57 T21 T25 T29 T33 T37 Adder Endurance: 0 electrical operations plus 20 mechanical operations. Pigtail wire size: 18 AWG (0.82 mm 2 ). Leads are orange and brown. Field Mounted Field Installation Kits Pigtail Leads UVH6RP02K UVH6RP03K UVH6RP05K UVH6RP08K UVH6RP11K UVH6RP29K UVH6RP20K UVH6RP21K UVH6RP23K UVH6RP26K UVH6RP28K Discount Symbol......................... CB-2 CA08101E