Plexo composable plate supports and boxes

Similar documents
P17 Tempra Pro plugs, mobile sockets, fixed sockets, surface mounting sockets and appliance inlets - IP 66/67-63 A A

P17 combined units LIMOGES Cedex Telephone : Fax : Cat. No.(s) : 566 XX XX XX XX

P17 plugs, mobile sockets and surface-mounting sockets «New range 16 and 32 A»

HYPRA Prisinter 16/32/63 A

Marina Cabinets LIMOGES Cedex Telephone: Fax:

High pressure industrial ball valves

2. RANGE. RAL 7035 Cabinets Vertical version (external dimensions in mm) Square version (external dimensions in mm) Supplied with plain plate (2) (1)

16/32/63A - IP44 plugs, mobile sockets, socket inlets and appliance inlets

Application Data Sheet. Chemical Compatibility Chart. IND-AS EN-01 (May, 2014) Metals Plastics Seals KEY. Good. Fair. Ethylene Propylene.

Issue One. Chemical Compatibility Guide

Selection of DODGE E-Z KLEEN Polymer and Stainless Steel Housed Ball Bearings. P = (X x F R ) + (Y x F A ) F A C o

Strength, resilience, rigidity - these are all attributes needed to combat arduous and aggressive conditions. Tufflite has them all.

TECHNICAL DATASHEET. Weatherproof LED luminaire ZALEDA EVOL II. 85,000 h product life. General characteristics. Mounting accessories.

TANK LINING RESISTANCE GUIDE I-19

Swivel Joints Flexmaster Joints Part Number NH NH NH NH NH NK NK

Q-Duct wiring duct. Q-Duct Wiring duct. Catalog number explanation QD 100 X 100 S G

TECHNICAL DATASHEET. Weatherproof LED luminaire DUNA FLEX Standard Plus. 50,000 h product life IK C. Applications recommendation

TECHNICAL DATASHEET. Weatherproof LED luminaire DUNA FLEX High Efficiency. 70,000 h product life IK C. Applications recommendation

Plexo 3 weatherproof cabinets

Pump Kits. More than just pumps

Socket. Extension. Connector Box. Extension. IP 44 and IP 66/67 plugs, mobile sockets, socket outlets and appliance inlets

XL³ 400 metal distribution cabinets, free-standing enclosures and cable compartments

ADVANCE System ADVANCE SYSTEM IP66 MODULAR SYSTEM FOR COMBINATION UNITS VERSIONS MODULE 136 MODULE 106. t. 56. Without protective devices

Pump kits. We deliver values.

How to Use the Chemical Compatibility Chart. Vials and Closures >> Chemical Compatibility Chart

Be prepared with Lutz. Safety is our concern

Metallic Systems TYPE SPTC

Small on price, big on boot

ULTRA LOW FRICTION SERIES

CONNECTION BULLETIN. Vogt Valves. Experience In Motion. Zero Leakage Forged Steel Check Valves Class 800. FCD VVABR /04 (Replaces CB-03)

workshop specifications Plexo³ IP 65 cabinets

KLINGER top-chem A milestone in PTFE gasketing KLINGERsoft-chem

Instruction Manual BL1.5 BL3 BL5 BL7 BL10 BL15 BL20. Dosing Pumps.

TECHNICAL MANUAL COMPRESSION FITTINGS

Fibreglass Reinforced Plastic

Grommet TET. Cable glands. Basic Data. Application. Press the grommet into the hole.

Installation Guide PHILMAC 3G TM COMPRESSION FITTINGS. Turn On To Faster Installation TM

Product Information S/PA

Safety Performance WORLD PREMIERE. palazzoli.com 1

Section 3 - Chemical/Environmental Resistance Part 1 - XR-5 Fluid Resistance Guidelines

FR PVC COATED RAINWEAR

Arteor TM International socket outlet

Hygienic Pump. Vitachrom. Type Series Booklet

Chemical Resistance Chart

KLINGER-KGS Rubber- Metal-Gasket

Physical properties of PET resins. 1. Intrinsic Viscosity (IV)

General applications Chemical plant, oil refinery, power plant, steam, Dowtherm, fused alkali, fuel oil and gas

We offer two fire retardant (FR) resins for strut systems: polyester and vinyl ester. Both resins are ideal for corrosive environments.

KLINGER KGS. Rubber-Metal-Gaskets Safe sealing of gases and liquids

FRP RADIAL FUME EXHAUSTERS/ PRESSURE BLOWERS THE NEW YORK BLOWER COMPANY

Information. Mechanical. Electrical. Chemical. Conversions & Calculations

Dead Level. Pre-sloped Trench Drain System. Watts.com

DURA SLAB PULTRUDED TECHNICAL SPECIFICATIONS January 2014

TEST REPORT: CHM12-01-LSM

TFP TEFLON RESIN PUMP PFR ACIDPROOF FRP PUMP. PT DUA PUTRI PERKASA INDEX CONTENTS PFR TFP

TECHNICAL INSTRUCTIONS DGP

NO: AC.2006.CT.01 شرکت کامپوزیت آسیاآسیا(سهامی تولیدکننده انواع قطعات کامپوزیتی گریتینگ و سینی کابل)

Delta Intercontinental Pte Ltd Tel : Fax: Woodlands Industrial Park E1, #

EF 8 EF 9. Company name Idemitsu Nippon Oil Cosmo Oil Showa Shell Sekiyu TonenGeneral Sekiyu Japan Energy

U.S. Tsubaki AS Series

13.1. Range of Enclosures. KRONECTION Box A 2 for up to 2 pairs. Expert Knowledge. Short survey of the KRONECTION Box A 2 for up to 2 pairs

XL Distribution enclosures WORKSHOP SPECIFICATIONS

New Pig One Pork Avenue Tipton, PA Chemical Compatibility Guide for: FTI Pumps

The Measure of all Things. Volumetric Solutions from Merck

150 Series Brass Horizontal Float Valve. Technical Information

Catalog June Mounted Bearings

Hose and Fitting Edition

The Air Logic Division of Fred Knapp

SUPERLIT GRP PIPE & FITTINGS AS AS GLASS REINFORCED POLYESTER (GRP) PIPELINE SYSTEM VERSION 1.0

CONTENTS Page

PHOTOSWITCH Liquid Level and Resistance Sensing Control Bulletin 13DJ3-3000

Technical Manual. The connection you can trust. The connection you can trust.

KML KML. Socketless cast iron system for aggressive waste water from kitchens and laboratories. Product information

PVC-LINK. High Impact, Complete Flexibility. Product Catalogue Cable Management System Distribution Enclosure & Weatherproof Boxes

The Industrial Choice. Model TFBD. Model FBD FIBERGLASS AXIAL FLOW FANS. Model FDP / FRV / FBD / TFBD / VTFBD

Dynaform Fiberglass Structural Shapes. Design Guide. High Performance Composite Solutions. Corrosion Resistant. Fire Retardant.

Dräger CMS Chip Measurement System

WASHGUARD Gear Reducers & GEAR+MOTOR

Atlantic stainless steel cabinet Cat. Nos : /01/02/03/04/05/06/07/08/09/11/12/13/

SETUP, OPERATING AND MAINTENANCE INSTRUCTIONS FOR PNEUMATIC CHEMICAL INJECTORS, SNAP ACTION RELAYS AND TIMERS

Plan the beginning... anticipate the end. STAINLESS STEEL ENCLOSURES

Electrical installation solutions for buildings Technical details Automation boards

STAINLESS STEEL VOLUTE PUMPS

MODERN PLASTIC INDUSTRY L.L.C. PP COMPRESSION FITTINGS. Reliability, Quality and Value

MITSUBISHI ELECTRIC E1032. Installation manual. English MA

Viale Borri Varese - Italy IDROBOARD weatherproof cabinets Cat. Nos :

TECHNICAL INSTRUCTIONS DGPT2

Synonym(s) ) Chlorine, liquefied/gas. Ammonia, Gasoline, natural 7300 (gasoline) Hydrogen gas. Phosgene

MATERIAL DATA SHEET TECHLITE LIGHT GREY ACOUSTICAL FOAM

Technical Manual TYPE 4X

Permissible overload. 22 A > A Hz > Hz 42 A > A. Heat resistance

Silhouettes of Rail Cars, Tank Trucks and Chemical Tanks

Double Containment Piping Systems Kendall Group Tech Summit Presentation

Dräger CMS. Dräger CMS: Highly accurate and easy to use. Dräger CMS Chip: Miniaturised Dräger-Tubes.

MITSUBISHI ELECTRIC E1071. Installation manual. English MA00777A

MM PISTON PUMP

Liverani S/P & MID Flexible Impeller Pump

BSM ROTARY GEAR PUMPS

Liverani VA Flexible Impeller Pump Variable speed, mechanically controlled

NO SHAFT SEAL, LESS PROBLEMS UP TO 200GPM AND 160 FEET MARCH PUMPS CENTRIFUGAL MAGNETIC DRIVE PUMPS

Transcription:

87045 LIMOGES Cedex Telephone : + 33 0 5 55 06 87 87 - Fax : + 33 0 5 55 06 88 88 Plexo composable Cat. No(s) : 696 51/56/61/68/72/78/79//81/83/85/87/89 CONTENTS Page 1. Technical characteristics...........1 2. Range.........................1 3. Installation...................1-2-3 4. Dimensions.....................3 5. General characteristics............4 6. Maintenance....................4 7. Specific uses....................5 8. Equipment and accessories........5 9. Compliance and approvals.........5 1. TECHNICAL CHARACTERISTICS Weatherproof wiring device system designed for residential and professional technical locations (garages, cellars, car parks, workshops and industrial kitchens, etc) as well as for outdoor applications (patios, gardens, camp sites, etc). Boxes with entry glands or cable glands and supports supplied with plate. Can take composable mechanisms. Boxes supplied with Nylbloc auto 2 conductor connection terminals, for future tap connections. 3. INSTALLATION 3.1 Surface mounting - By screwing back box onto support using Ø 3 mm - Ø 4 mm max. screws. - Drilling template available, Cat. No. 695 97 (see page 5). 81 2. RANGE Description Commercial Cat. No. Weight Cat. Nos. 2 versions : grey and white COMPOSABLE SURFACE MOUNTING 3 entries 696 51 696 89 696 72 696 90 696 61 696 91 696 696 79 AVAILABLE JAN 2008 g 132 g 132 g 192 g 192 g 695 xx 696 xx 697 xx 698 xx Composable Complete surface mounting Complete flush mounting 194 123 142 COMPOSABLE FLUSH MOUNTING CABLE GLAND BLOXES 1 entry 696 81 696 92 696 83 696 94 696 85 696 96 696 87 696 98 696 56 696 78 696 68 42 g 70 g 70 g 96 g 56 g 140 g 140 g - Replacing former Plexo 55 series. 127,5 38 146 1/5

3. INSTALLATION (continued) 3.2 Flush mounting - Unclip plate Cat. No(s) : 696 51/56/61/68/72/78/79//81/83/85/87/89 3.3 Mounting and sealing - 2 visible mounting points, centre distance maintained (Plexo 55) except three-gang boxes. - Fixings are sealed by a gasket overmoulded onto the back of the boxes (except cable gland boxes). - 2 centre distances maintained : - With screws on flush mounting box Use of Batibox flush mounting boxes (centre distance mm for multi-gang supports). - For cable gland boxes, the covers supplied must be fitted as the boxes have no gasket on the back. 142 - With claws on flush mounting box Claws can be fitted : Cat. No. 9 00 or Cat. No. 9 01 (long claws) - On solid faceplate using Ø 4 mm screws. Drill support material (diameter - 70 mm) using hole saw or hole punch. 3.4 Conduit connection Type of conduit : - IRL : formerly IRO, insulating rigid smooth tube } - ICA : insulating flexible bendable corrugated tube - ICTA : insulating flexible transversally bendable elastic corrugated conduit Ø 16-25 mm - ICTL : insulating flexible transversally bendable elastic smooth conduit Cables (examples) : - rigid conductors : U - 1000R2V 3G2.5 - flexible conductors : H07 RN - F 3G2.5 Type of entry gland : flexible with membrane, 2 removable types. - entry gland with 1 entry supplied with and boxes (top). - entry gland with supplied with and boxes (bottom). 132 61 Ø - 70 mm 66 2/5

Cat. No(s) : 696 51/56/61/68/72/78/79//81/83/85/87/89 3. INSTALLATION (continued) 4. DIMENSIONS Surface mounting Ø 4 - Ø 15 mm Ø 16/20/25 mm 20 53 Also available as accessories : - 695 96 grey entry gland 1 entry - 695 99 grey entry gland - 696 46 white entry gland 1 entry - 696 49 white entry gland 3.5 Assembly - Composable motors mounted by clipping into the back of the box. Flush mounting 18 28 228 - Removing the partitions from two and three gang boxes facilitates access and allows two and three gang prewired socket mechanisms to be fitted. 157 222 222 155 151 CLIC CLIC 157 Surface mounting + cable gland 16 IP55 sealing on front part (cover) on the box is ensured by rotating four 1/4 turn fixings. The direction of rotation of each 1/4 turn fixing is shown by an arrow on the cover. 91 151 53 1/4 166 155 91 3/5

5. GENERAL CHARACTERISTICS 5.1 Mechanical characteristics Protection rating : - IP 55 IK 07 5.2 Material characteristics Materials Box, support : PP (filled Polypropylene) Plate : ABS (Acrylonitrile-Butadiene-Styrene) Entry gland : PP + SEBS (Styrene-Ethylene-Butadiene-Styrene 5.3 Resistance to chemicals Behaviour Acetone... - Acetic acid (10%)... + Acetic acid 30 %... + Aminosulphonic acid... - Boric acid *... + Hydrobromic acid (47%)... - Hydrochloric acid *... - Chromic acid... + Citric acid *... + Hydrofluoric acid *... - Formic acid... - Lactic acid *... + Linoleic acid... - Maleic acid... + Nitric acid (30%)... - Nitric acid (50%)... - Perchloric acid (10%)... + Benzenesulphonic acid... - Phosphoric acid *...... - Sulphuric acid... + Tannic acid *... - Tartaric acid *... + Ethanol... + Alcool isopropylique... + Methyl alcohol (methanol)... - Phenylethylalcohol (100%)... - Ammonia... + Baths for electroplating : - Bright silver bath... + - Bright cadmium bath... + - Chromium plating bath (50 C)... + - Copper bath (with potassium cyanide)... + - Copper bath (acid)... + - Pickling bath with chemical copper plating... + - Brass bath... + - Bright nickel bath... + Barium - Barium chloride *... + - Barium hydroxide *... + - Barium nitrate *... - Benzene... - Beer... + Calcium hypochlorite *... + Cobalt chloride *... - Cupric chloride *... - Ferrous chloride *... - Manganese chloride... - Mercuric chloride *... - Methylene chloride... - Chlorine water (wet gaseous chlorine)... - Sea water... + Fertiliser... + Epichlorohydrin... - Heavy gasoline... - White spirit... - Turpentine... - Essential oils... + Linseed oil... + Lubricating oil... + Cat. No(s) : 696 51/56/61/68/72/78/79//81/83/85/87/89 Machine oil... + Mineral oil... + Paraffin oil... + Fish oil... + Castor oil... + Silicon oil... + Humus... + Aqueous hydrogen sulphide... + Hypochlorite of soda (10%)... + Fruit juice... + Milk... + Chlorinated lye... + Margarine... + Fuel oil... + Mercury... + Methyl methacrylate... - Silver nitrate*... + Cobalt nitrate*... + Manganese nitrate *... + Mercuric nitrate *... + Nickel nitrate*... + Lead nitrate *... + Petroleum, petroleum ether... - Silicate (Potassium, Sodium)... + Syrup (beetroot)... + Sodium - Sodium acetate*... + - Sodium bromate*... + - Sodium chloride* (salt)... + Caustic soda 40 %... + Monomer styrene... - Sugar... + Trichlorethylene... - Urine... + Wine... + * all concentrations in aqueous solution Key : + resistant - unstable This information is given as a guide only and can not be construed as an undertaking on the part of the manufacturer. Please contact us for specific uses. 5.4 Resistance to ultraviolet radiation No notable alteration following the 7 day test with 550 W/m 2 power lighting (Colorimetric measurement using lab method). 5.5 Resistance to salt spray : 7 days (168 hrs) 5.6 Electrical characteristics - Self-extinguishing in accordance with IEC 695-2-11 : components (or parts) required to secure live parts : 850 C components (or parts) not required to secure live parts : 650 C - Voltage - Current - Frequency 16 A 250 V~ 50 Hz in accordance with NF C 61-314, NBN C 61-112 and IEC 8-1. 5.7 Climatic characteristics Storage and operating temperature : - 25 C to C 6. MAINTENANCE Clean surface with dry cloth or cloth soaked in soapy water. Do not use acetone, tar remover or trichlorethylene. Warning : a prior test is required before using specific cleaning products. 4/5

A Plexo composable 7. SPECIFIC USES Installations with profile. The Plexo profile distribution system provides : - Distribution, protection and branch connection of various wires and cables in an electrical installation. - A profile, finishing and routing accessories (profile joint, weatherproof universal junction, flat angle, internal angle, external angle, branch connection, bracket). - A new solution for installing weatherproof surface mounting switchgear installations in domestic and occasionally tertiary technical situations. - Optimum safety and reliability due to compliance with standard NFC 68-104 (IP 42, IK 07). Cat. No(s) : 696 51/56/61/68/72/78/79//81/83/85/87/89 8. EQUIPMENT AND ACCESSORIES Description Uses Cat. Nos. Colour Entry gland 1 entry Entry gland Drilling template Used to provide an aesthetic connection between boxes and cables up to Ø 16 mm inclusive Used for fast identification of mounting centre distances of all boxes 695 96 Grey 696 46 White 695 99 Grey 696 49 White 695 97-694 81 694 83 Set of 4 covers Used to blank mounting holes at bottom of boxes 695 98 Grey 694 85 694 Standard claw Clips on to all flush mounting supports 9 00 694 Long claw 9 01 694 81 694 694 82 IP 55 Branch connection terminal block Direct connection after simply stripping rigid conductors. Terminal capacity : 0.75-2.5 mm 2 343 22 9. COMPLIANCE AND APPROVALS Cat. Nos. Description 694 Plexo profile, length 2.00 m capacity equivalent to a Ø 25 mm IRL 694 81 Plexo profile bracket 694 82 IP55 weatherproof universal connection 694 83 Plexo profile internal/external angle 694 Plexo profile flat angle 694 85 Plexo profile tee Products manufactured in accordance with the following standards : - French NF C 61-314 - Belgian NBN C 61-112 - International IEC 8-1 Quality marks Standards Date NF (France) CEBEC (Belgium) CEBEC NF C 61-314 03/10/2006 IEC 8-1 09/03/2007 694 Plexo universal junction - Refer to the specific technical sheet for Plexo profile, technical sheet : F003FR/00. 5/5