Series 577. Vertical Flow Softwall Portable Cleanroom. Series 577 Vertical Flow Softwall Portable Cleanroom

Similar documents
Series 301. Horizontal Laminar Flow Clean Bench. C l e a n B e n c h e s. s o l u t i o n s. Series 301 Horizontal Laminar Flow Clean Bench

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment

Clean Air Products Straight Thru Standard Profile Single Door Air Shower Purchase Specification

After installing the HEPA filters the discharge air should be monitored to ensure proper filtering efficiency. HEPA Filters

1 of 5. Hepa Technologies Sdn. Bhd. AmAir 300X, RigiFil, AstroCel I. VariCel II

SECTION HVAC AIR CLEANING DEVICES

1000 Park Drive Lawrence, PA Fax

TH Series UL 900 Class 1, Factory Mutual Approved, Truly Separatorless Filter Modules

PRECISE. Glove Boxes

Ventilated Balance Enclosures

One Circuit Trac System TRAC SECTION, JOINERS & FEEDS T Series

FiberGuide Fibre Management Systems

TH Series UL 900 Class 1, Factory Mutual Approved, Truly Separatorless Filter Modules

TABLE OF CONTENTS SPECIFICATIONS 3 INSTALLATION 4. Direct Mount 4. Ducted Installations 5. Installing Plenum 5. Machine Mount Stand 5.

TXH TOTAL EXHAUST HOOD. Installation and Operations Manual

Annexure-1. Annexure- 1 TECHNICAL SPECIFICATIONS FOR THE MODULAR LABORATORY FURNITURE (CNSNT/RL-4)

PHARMACY Products. Compounding Aseptic Containment Isolator (CACI) A level of safety that is built in, not bolted on. Underwriter Laboratories Listed

HOWORTH EXFLOW 28 PREVENTS AIRBORNE INFECTION TECHNICAL SPECIFICATION. Exflow 28 Technical Specification. Page 1 of 7

OmniAire Portable Air Cleaner OA1200PAC

System Benefits. Index. Style 840The amazingly versatile woven wire partition. The Style 840 Solution

Model ND-2 Specification

A viewscreen top hinge allows full opening for loading of instrumentation or equipment.

SterilSHIELD. Designed for Aseptic Compounding of Non-Hazardous Pharmaceuticals. SterilSHIELD Barrier Isolator (positive pressure)

Self-Repairable High Speed Doors Standard Interior - 100SR Low-Temp - 104SF Interior Reinforced - 110RI Exterior Reinforced - 140RA

Lighting Systems Argus-7

INTEGRID TRACK (120V) SPECIFICATIONS

Fitting Room Systems & Mirror Kits

IN STAL LA TION IN STRUC TIONS FOR CON CEN TRIC DIF FUSER

One Circuit Trac System TRAC SECTION, JOINERS & FEEDS T Series

DESIGN-AIRE SL-RSR-EC. Installation and Operations Manual

CLEAN AIR WORKSTATION REVERSE FLOW. Installation and Operations Manual

: PVC

Two Circuit Trac System TRAC SECTION, JOINERS & FEEDS

READ AND SAVE THESE INSTRUCTIONS. Air Boss MP600M Vertical Air Flow Mist Precipitator Industrial Applications. TRION

Biological Safety Cabinet

Purifier Logic Class II Biosafety Cabinets FEATURES & BENEFITS

CEILING AIR INLETS CORROSION PROOF ECONOMICAL DURABLE. Ideal for all Agricultural applications.

Juno Trac-Master Trac Lighting Systems. Comprehensive line and low voltage track systems

PCR Laminar Flow Cabinets

MANCOOLERS. Macheta Airfoil Propeller Model UM / PUM / M39 / STL. Utility Mancooler Model UM. Pedestal Mount Mancooler Model PUM

Two Circuit Trac System TRAC SECTION, JOINERS & FEEDS

TRAC-LITES One Circuit Trac System TRAC SECTIONS & SYSTEM COMPONENTS R Series

ADVANCED SAFETY ENGINEERING FOR EFFECTIVE HANDLING OF HAZARDOUS PARTICULATE DRUGS AND POWDERS IN A CLASS II, TYPE A2 BIOLOGICAL SAFETY CABINET

OFFICE PARTITIONS. Data Port Openings. Use cable tie bracket to dress data cables under panels. STEP 1

BioPROtect III. and BioPROtect III Jr. Class II Style Walk-In Clean Air and Containment Enclosures.

& 12" 96" / TABD CATALOG

SURFACE TRACK (120/250V) SPECIFICATIONS

CLEANROOM PRODUCTS FLUSH HEPA GRID WITH INTEGRAL LIGHTING PLENUM MODULES CUSTOM AIR HANDLERS PLENUM MODULES FAN POWERED PLENUM MODULES

KASON SLIDING DOOR HARDWARE

ANATOMY DISSECTION TABLES

H E AV Y G L ASS PROLINE DESIGNER SERIES

MICRO SEAL-SERIES HEPA Holding Frames and Housings

ROOF HATCHES. Over 45 years of proven performance in Standard & Custom Designed Hatches SINCE 1965 NOW WITH R-20 INSULATED ROOF HATCHES!

Operations & Maintenance Manual DFH-1000 DUCTLESS FUME HOOD

Consider The Possibilities...

BACK STRAP REMOVAL AND PREPARATION TOOL MODEL # BSRT-15/10

BioMAX. Koch Filter Corporation. A Complete Line of HEPA Filters for Hospital, Commercial and Industrial Applications

PLASTIC BIN SUPPORT RACKS

Protector Demonstration Hoods

INSTALLATION INSTRUCTIONS

Indianapolis Power & Light Company

Ductless Nanoparticle Containment Enclosures

Precise Glove Boxes & XPert Weigh Boxes

PHARMACY Products. Compounding Aseptic Isolator (CAI) Positive pressure sterility assurance barrier isolator for complete product protection.

forward curved inline duct blowers

channel bracket 1.50 (38) flat strap shaded area is useable space

PROTECTOR FIBERGLASS ENCLOSURES

Requires Ductwork and Blower

Protector XStream Laboratory Hood is shown with SpillStopper Work Surface , Protector Acid Storage Cabinet and Protector

B. Base occupied space sound level estimates on ARI 885. C. Terminal heating coils shall conform to ARI 410.

Direct Gas-Fired Heating

(Class II Type A2 & B2)

MONOGRAM 36" BUILT-IN BOTTOM-FREEZER REFRIGERATOR

MiniRoom. Isolation cubicles flexibility with containment. Horizontal laminar flow of air for greater protection - positive or negative

In This Section Portable Hot Box Aluminum For Transport J ER-18 Enclosed Rack For Display J

Climas y Proyectos Leyco, S.A. de C.V.

MONOGRAM 36" BUILT-IN BOTTOM-FREEZER REFRIGERATOR

STATE OF NORTH CAROLINA D DEPARTMENT OF ADMINISTRATION MARCH 20, 1995 PURCHASE AND CONTRACT DIVISION 7125-LM-2C November 9, 1989

PVC Strip Door Curtains & Swing Doors

CONTENTS KASON PRODUCT LINES THERMAL FLEX VINYL TRAFFIC DOORS... C2 THERMAL FLEX VINYL SWING DOORS...C3 SURE SWING HINGE...C3

MODEL MC1500 Installation and Operation Manual Important:

2000 Watt Telescoping Light Mast - 30' 3-Stage Light Tower Rotating Boom - High Mast Lighting

CANOPY HOOD ACCESSORIES

Clipper Defined. Shelving. Clipper Hi-Performance Shelving Systems. Growth with. Penco Hi-Performance Shelves. Growth with

DESIGN-AIRE SL-RSR-EC. Installation and Operations Manual

Omniaire 1000V Instruction Manual-8/05

MONOGRAM 36" BUILT-IN BOTTOM-FREEZER REFRIGERATOR

READ AND FOLLOW ALL SAFETY INSTRUCTIONS! SAVE THESE INSTRUCTIONS AND DELIVER TO OWNER AFTER INSTALLATION.

HORD HOSPITAL OPERATING ROOM AIR CURTAIN

Plastic Diffusers & Grilles

Class II biological safety cabinets

3000 Watt Pneumatic Light Tower - Extends to 18 Feet - Three 1000W Metal Halide Lamps

GE Monogram 36" Built-In Bottom-Freezer Refrigerator

Unimodule M2 Unidirectional Flow Clean Bench/Workstation OPERATION MANUAL

F. VAV hoods shall have a restricted bypass plate.

DRYING SYSTEM ASSEMBLY AND OPERATING MANUAL

HW, WA, WRSN and WRSM Series

Full-featured operator with slim profile for moderate to high traffic applications LOW ENERGY OPERATOR CATALOG

CHAPTER S e t u p NOTICE:

1.6 Accessories include tool-free snap-in technology options for air flow, cable management, shelves, power distribution units, etc.

Transcription:

Series 577 Vertical Flow Softwall Portable Cleanroom s o l u t i o n s The Series 577 softwall portable clean rooms are a cost-effective method of providing quality particulate control enclosures. The system utilizes proven clean room manufacturing and design techniques to provide a lightweight, low-cost, easy-to-assemble clean room system. A variety of sizes and shapes are available to ensure a system that is matched to individual needs. The portable clean rooms are available from Class 100,000 to Class 10. They typically operate as positive pressure enclosures but can also be used as negative pressure containment areas to HEPA filter all the outgoing room air. The lightweight, easy-to-assemble sections have a maximum size of 12 ft. x 12 ft. with a leg on each corner. Larger units can be constructed by simply adding on standard room components to create one continuous room with support legs on a 12 ft. x 12 ft. pattern. A 24 ft. x 24 ft. room would have one center post. The rooms can be expanded or reduced in size without taking the entire clean room down. This feature makes it fast and easy to add sections or change the shape for other requirements. A number of smaller rooms can be combined for a large clean room project and then be changed back to smaller rooms and relocated at a later time. Features v Lightweight, easy-to-assemble 2 x 4 in. tubular steel frame with 2 x 2 in. tubular steel support legs v Modular design offers great flexibility and expandability v Room Class 100,000 to Class 10 v Complete with motorized ceiling HEPA filters, lights and prefab wiring kit Requires only assembly and electric power connection v Rigid acrylic panels are an option to create a hardwall clean room v Fast delivery; most portable clean rooms shipped from stock 8 For more information or to download or fax this product from the web, simply go to: www.cleanairproducts.com/577

C l e a n r o o m s Construction This portable clean room s frame is constructed of high-strength tubular steel with a white baked-enamel finish. The tubes are bolted together to form the upper frame assembly to which the tubular steel support legs are attached. The frame is lightweight to allow the frame and components to be hand-lifted and assembled. One person can assemble the rooms, but it is easier to do with two people. The tubular steel frame is constructed to form the top surface which supports the filters, lights, and blank panels. Tee bar dividers attach to the frame between the filters, lights, and blank panels. The tee bars provide the mounting surface and hold the filters, lights, and blank panels in place. General Features 99.99% DOP test on 0.3 micron HEPA filters Aluminum-frame HEPA filters White lights Clear vinyl curtains 120-volt filters and lights White painted finish The rooms use the CAP112-424 (2x4) motorized ceiling HEPA filter, CAP1210-2x4 (4) lamp Seal Tight clean room light or the CAP1220-2x4 (4) lamp flow-thru light and blank ceiling panels in various quantities, depending on the size and class of clean room. The perimeter of the room is enclosed by a clear, polished-vinyl curtain or optional acrylic panels. These are easily attached to the room by 3M Dual Lock (clean room Velcro type material). Optional styles and materials for hardwall sided rooms are also available. The rooms can be furnished with a prefab wiring kit for quick and easy connections of the filters and lights to a single electrical connection. Options (consult factory for additional items) ULPA filters (Class 10) Strip doors NON DOP test filters Yellow or opaque curtains Special room heights Casters Ionization Prefabricated wiring kit Acrylic or lexan walls Gowning rooms Economy swing doors All stainless steel frame Building suspension bracket Curtains Standard clean room curtain dimensions are clear 40 mil vinyl with Velcro strips sewn in along the top for mounting. All standard and optional curtain dimensions will be 54 in. x 90 in. x 40 mil thick. To enter or exit the clean room, the curtains are simply spread apart at the seams. The curtains automatically reseal as the two halves come back together. Optional Material: Static or non-static dissipative curtains are available 13 mil yellow vinyl curtain is available with channel or Velcro mounting; this curtain can be used for ultraviolet light filtration or photoresist applications (yellow static dissipative not available) Clear conductive 20 mil vinyl with a diamond-shaped grid bonded to one side; these curtains are constructed to allow for grounding, so the carbon grid can dissipate the surface charge to ground. Attached with channel top mounting and chain bottom. Black herculite Yellow 13 mil used for ultraviolet light filtration; this can also be used with photo resist applications; attached with channel-top mounting and chain bottom. NOTE: Special extra length curtains are available for all of the above materials. Strip Doors The strip door consists of (8) 8-in. x 80 mil. thick strips with 2-in. overlap on each side along the length. The strip doors are shipped assembled, with mounting angle on top. Optional Material: Heavy 125 mil clear vinyl strips for high traffic areas Clear anti-static vinyl Clear flame-retardant anti-static vinyl Yellow standard vinyl Yellow flame-retardant vinyl Other strip door options available upon request. Clean Room Ceiling Height Requirements The standard height dimension is 8 ft. Standard filter unit height is 14 in. A 2-in. minimum space is required between the filter unit top and ceiling. Standard room heights are 7, 8, 9, 10, and 12 ft. Other clean room heights are available. Flow-thru lights add 5-1/2 in. to standard filter unit height (see flowthru light description listed in this document). Acrylic or Lexan Walls With Economy Swing Door Standard clean rooms consist of softwalled vinyl curtain and/or strip doors. Acrylic or lexan panels provide a sturdy, attractive and economic clean room wall option. These panels are attached to the steel framing with 3M Dual Lock (clean room Velcro type material). 2 S o l u t i o n s B u i l t t o

Economy swinging doors also consist of these panels attached with Velcro to steel framing. Included with the economy door are hinges and a door closer. NOTE: Panel length is cut to allow for a 12 in. opening along the bottom of the entire clean room to achieve proper air flow. Tee Bar Seal Tight Gasketing System The clean room ceiling consists of ceiling lights, filter units and blank panels that fit into a 2 ft. x 4 ft. seal tight tee bar ceiling grid system. Gasketed filter units, clean room lights and vinyl-covered ceiling panels provide a zero-leak clean room which is essential for optimum clean room performance. Clean Room Ceiling Lights (standard) Cleanroom lights consist of a 2x4-4 lamps, 120V, 60 Hz, 1.0 Amp enclosed seal tight white fluorescent panel light. The clean room lights are set into the tee bar ceiling grid system. Gasketing provides the seal between the tee bar mounting surface and the light housing surface. Flow-Thru Lights Flow-thru lights are similar to standard clean room lights with the exception that a motorized ceiling HEPA filter unit is mounted directly on top of it. This light fixture is open enough that filtered air is able to flow through the light fixture down into the clean room. Flow-thru lights are used when space for lighting is limited. For example, Class 10 conditions require 100% ceiling filter unit coverage. Providing the light sources beneath the filter unit becomes a viable solution to this space limitation. Flow-thru lights are also valuable in situations where concentrated clean areas and lighting need to be achieved within a clean room. The filter unit and light fixture are joined together at the factory with fasteners to form one complete flow-thru light unit. Casters Casters with brakes are available on clean rooms. Consult factory for rooms over 12 ft. x 12 ft. Anteroom or Gowning Room Areas Anterooms (to perform pre-clean room procedures) or gowning rooms are modular and can easily be added to the clean room. Mobility can be added to these rooms by adapting them with the caster option. The anterooms and gowning rooms can then be relocated to another location along the outside perimeter of the clean room for adaptation or modifications to manufacturing processes. Prefab Electric Wiring Kit Clean Air Products offers a prefab electric wiring kit as a cost-effective and time-saving option to conventional electrical wiring. It facilitates quick and easy plug together type electric connection of the lights and filter units by assembly personnel. The electrician simply connects power to a single point. The plug together male/female connectors included with your prefab wiring kit are Reloc brand connectors. They are designed to be repeatedly plugged and unplugged as necessary. Basic Components The basic components included with your prefab wiring kit are as follows: Metal plug together male/female connectors and plug together flex metal cable segments. Electrical junction box. Lights and ON/OFF light switch. Connections The plug together system consists of Reloc brand metal connectors and Reloc brand metal flex cables. The plug together system provides connection between the ceiling lights, filter units and junction box, and is UL listed. Electrical Junction Box The electrical junction box receives your building-supplied electric power source. It is located on the top horizontal beam near the outside corner of the clean room. Lights and ON/OFF light switch Ceiling lights will be on their own separate 20 amp max. electric circuit and will be controlled by a standard light switch(s). The ON/OFF switch is conveniently located on the clean room corner leg outside the curtain below the junction box. Filter Units CAP112-424 filter units will also be on their own separate 20 amp max. electric circuit (2.8 RLA per filter unit). Each filter unit will have an electric junction box that has its own ON/OFF switch mounted to it. Filter units also have a 3-speed switch to designate low, medium, and high speeds. The filter unit ON/OFF switch is not exposed to the clean room ceiling interior. An adjacent ceiling panel can be removed to gain access to it if necessary. NOTE: Filter units and ceiling lights will not be on the same circuit. Speed Control The CAP112 fan filter unit (FFU) has a 3-speed switch located on the top of the unit. Low, medium, and high speeds are selectable. The switch can S o l u t i o n s B u i l t t o 3

C l e a n r o o m s be moved to compensate for filter loading. If closer airflow adjusting is required, see option 1 or 2. Option 1 Manually adjustable variable speed control located on top of the FFU. The speed is adjusted by turning a knob on top of the FFU. Option 2 Automatic speed adjustment. This speed control has a built-in sensor that measures the airflow of the unit. Once set, it will maintain a constant velocity until the filters need to be changed eliminating the need to manually increase filter speed. Assembly Electrical assembly is simplified because all connections can be completed with a continuous series of the plug together type cable segments and connectors. The electric power for each series of lights and filter units begin with a plug together cable connection being established at the clean room electrical junction box. This cable then continues on to connect any number in a series of lights or filter units within their circuit. NOTE: Set the lights and filter units in place. It is easiest to start closest to the clean room s prefab kit included electric junction box plugging in any number in a series of light or filter circuits. Each ceiling light and filter unit has its own electrical junction box to which the cable connector is mounted. The cable is then connected to the connection on the electrical junction box to complete the electric power connection. The cables have plug together connectors attached on each end. These cables allow a series of connections to be made between any number of filter units or ceiling lights within their circuit. NOTE: Reloc cables also have a connector on one end that is a 2-in-1 connector. One of the 2-in-1 connections of this single connector establishes connection to the next light or filter in the series. The other connection of this single 2-in-1 connector connects to the receptacle connector of the light or filter unit and supplies power to them. Serviceability The plug together prefab wiring kit makes connect and disconnect of ceiling light and filter unit for maintenance fast and easy. Cleanroom light and filter unit relocation and additions can be made quickly be using the plug together connectors. 4 S o l u t i o n s B u i l t t o

H 0 H 1 4 Guarantee A written 1 year Warranty is furnished with each cabinet. W L Standard Sizes Width Length (in.) (in.) 4 ft. x 4 ft. 50 50 4 ft. x 6 ft. 50 78 4 ft. x 8 ft. 50 99 4 ft. x 10 ft. 50 123 4 ft. x 12 ft. 50 146 6 ft. x 6 ft. 74 74 6 ft. x 8 ft. 74 99 6 ft. x 10 ft. 74 123 6 ft. x 12 ft. 74 146 8 ft. x 6 ft. 99 74 8 ft. x 8 ft. 99 99 8 ft. x 10 ft. 99 123 8 ft. x 12 ft. 99 146 10 ft. x 10 ft. 123 123 10 ft. x 12 ft. 123 146 12 ft. x 12 ft. 146 146 Outside dimension shown. Standard inside height is 8 ft. Other inside heights available upon request. Can make clear spans up to 24 ft. Consult factory for details. Common Larger Combined Sizes: Combined smaller sections to form larger enclosures. 8 ft. x 16 ft. 8 ft. x 20 ft. 10 ft. x 16 ft. 10 ft. x 20 ft. 12 ft. x 16 ft. 12 ft. x 20 ft. 12 ft. x 24 ft. 16 ft. x 16 ft.* 16 ft. x 20 ft.* 16 ft. x 24ft.* 20 ft. x 24 ft.* 24 ft. x 24 ft.* 24 ft. x 36 ft.** The above are standard sizes and are the most costeffective. Special sizes are available upon request. * = number of interior support legs. (i.e. * = 1, ** = 2) Note: Optional heavy-duty beams can span up to 24 ft. Consult factory for details. Specifications subject to change. Please contact factory for details. S o l u t i o n s B u i l t t o 8605 Wyoming Ave. N. Minneapolis MN 55445 fax: 763.425.2004 e-mail: sales@cleanairproducts.com Clean Air Products 2011 PM0577-1F 12.13.11