Solenoid Operated Directional Valve

Similar documents
Solenoid Operated Directional Valve

Sepehr Hydraulic Asia

Directional Controls

Directional Controls

Mobile Directional Valve. Product Catalog MDG for Mobile Equipment Flows to 60 I/min (15.8 USgpm)

Directional Valves. Pilot Operated Directional Valves. Vickers. Service Data

Directional Controls

Directional Controls

D03 FluiDyne Valves. ENGINEERING DATA

Service Data Vickers. Directional Valves. Wet Armature Solenoid Operated Directional Control Valves DG4V4-01, 1* /EN/0799/S

(F*) - DG5V -10- * - (R) - (B) - **(L) - (**) - (X) - (*) - (E) - (T) - (*) - (V)M - (S*) - * ** * * (L) - (*) ** - (***) (EN***)

Vickers Pressure Relief Solenoid Operated, Two-Stage Directional Control Valve DG5S4-02 Flows to 115 l/min (30 USgpm) Pressure to 210 bar (3000 psi)

Cartridge Valves Technical Information Directional Valves DCV 03

XCEL80 Steering Control Units

Directional Controls

VSD05M-S - SOLENOID OPERATED DIRECTIONAL ANTI-SHOCK VALVES

Eaton. Revised April, Directional Control Valves. Model 30540, 15 GPM Directional Control Valves. We Manufacture. Solutions

SV9A-10-E - Solenoid Valve 4-way, 3-position spool type solenoid valve Up to 36 L/min (9.5 USgpm) 210 bar (3000 psi)

Solenoid Valves. Poppet and Spool type solenoid actuated valves for applications up to 350 bar (5000 psi) and 227 L/min (60 USgpm) A-1.

Mobile Valves Proportional - Load Sensing

MDG Mobile Directional Valve Build Kit. MDG for Mobile Equipment Flows to 60 I/min (15.8 US gpm)

DIRECTIONAL CONTROL VALVE SOLENOID OPERATED TYPE HD3-ES-*-/10 CETOP MPa HD3 - ES - (1) (C) - * - (024C) (-) / 10

Directional Control Valve Series D3W Soft Shift

Solenoid valves. Poppet and Spool type solenoid actuated valves for applications up to 350 bar (5000 psi) and 227 L/min (60 USgpm)

4/2 and 4/3-Way Proportional Directional Control Valve Direct Operated

Directional Control Valve Series 4D01 (DENISON)

ANTI-SHOCK DIRECTIONAL CONTROL VALVES

VSNG10 - SOLENOID OPERATED DIRECTIONAL VALVES

Directional Controls

Char-Lynn Steering Control Unit. Repair Information

CMA200 Advanced Subject Independent-Metering title Mobile Valve. 200LPM 440 bar CAN Bus

Proportional Valves. Proportional solenoid valves for pressure and flow control

Directional Control Valve Series D3W (Parker), 4D02 (Denison)

D05 Directional Control Valves

ISO 5599/ Series Technical and Operating Data

RPE3-04. Functional Description HA /2010. Directional Control Valves Solenoid Operated. Replaces HA /2007

DS5JB /110 ED SOLENOID OPERATED DIRECTIONAL CONTROL VALVE. Q max 32 GPM ALTERNATING CURRENT SERIES 10

DRV2-080 Adjustable, Direct-Acting Relief Valve

SD2E-A3. Functional Description. 3/2 Way Solenoid Operated Directional Control Valves Spool Type HA /2013. Replaces HA /2012

SD3E-B2. Functional Description. 2/2 Way Solenoid Operated Directional Control Valves Poppet Type HA /2012. Replaces HA /2010

VSD10M DIRECTIONAL CONTROL VALVES SOLENOID ACTUATED, PILOT OPERATED

Pilot Operated Directional Control Valves Series D31DW, D41VW - D111VW

Char-Lynn HP 30 Motor

VS6M - SOLENOID OPERATED DIRECTIONAL VALVES

RPEW4-10. Functional Description HA /2012. Solenoid Operated Directional Control Valves with Wirebox. Replaces HA /2006

Directional Control Valve Series D1VW

220 Piston pump Service manual AEC 028

p max (see table of performances) Q max (see table of performances) bar Maximum flow rate from port P to A - B - T l/min

Ultronics ZTS16 Twin Spool Valve

Char-Lynn T-Series General Purpose Geroler Motor

DL /118 ED SOLENOID OPERATED DIRECTIONAL CONTROL VALVE COMPACT VERSION SUBPLATE MOUNTING ISO p max 280 bar Q max 50 l/min

Electrical Interface Dimensional Drawings Connector Kits

Stand alone 4/3, 4/2 direct acting directional valve LF2_1 (LC2F-DZ)

Pilot-Operated Directional Control Valves Series D3 - D11

Chapter 2: Directional Control Valves

Eaton Power & Motion Controls. EDM Show Specials. Power & Motion Controls

unrestricted; preferably with coil at bottom (auto. air bleed) 12 or 24 Volt DC from an electronic controller Deutsch plug - IP67

SD2E-A4. Functional Description. 4/2 Way Solenoid Operated Directional Control Valves Spool Type HA /2014. Replaces HA /2013

5 Port Direct Operated Poppet Solenoid Valve, Rubber Seal

Directional Controls

RNEH4-25. Functional Description HA / /2 and 4/3 Way Directional Control Valves Pilot Operated. Replaces HA /2012

20 l/min (5 GPM) p max. Technical Features

Directional spool valves, direct operated, smoothly switching, with solenoid actuation

40 l/min (11 GPM) p max

5 Port Solenoid Valve Direct Operated Poppet Type. Specifications

SOLENOID VALVES NFPA D03 NFPA D05 D03 & D05 SERIES 35- SOLENOID VALVES. Features. Internal Structure NFPA SIZE: D03 & D05

Directional Control Valves. General Description. Features. Specifications

4/3-4/2 Directional valve elements LF1_1 (LC1F-Z)

RPE3-04. Functional Description HA /2013. Directional Control Valves Solenoid Operated. Replaces HA /2010

DIRECTIONAL CONTROL VALVES CETOP 3/NG6

Pilot Operated 2 Port Solenoid Valve for Dry Air

Hydraulic Screw-in Cartridge Valves (SiCV) Proportional valves Proportional solenoid valves for pressure and flow control

Proportional Valves. Proportional solenoid valves for pressure and flow control B-1.A. An Eaton Brand

3/2 ways/positions flow diverters L (VS91-VS92-VS95)

D4D SOLENOID OPERATED DIRECTIONAL CONTROL VALVES DIRECT CURRENT - SERIES 50 ALTERNATING CURRENT - SERIES 60

Char-Lynn Power Steering. Parts Information. 110, 230, and 450 Series. July, 1999

620 Mobile open circuit Piston pump service manual ADY074 ADY098

Fixed Displacement Swing Drive Motor. JMF Axial Piston Motor Peak Pressure: 385 bar Displacement 29~250 cc/r

3 Port Solenoid Valve Direct Operated Poppet Type

Directional spool valves, direct operated, with solenoid actuation. Type WE

Eaton. Revised June, Heavy Duty Hydrostatic Transmissions. l r. Models 33 through 76 Hydrostatic Transmissions. We Manufacture.

4/3 and 4/2 on-off directional valve elements L8511 with flow (EDC-DZ) sharing control (LUDV concept) L8511 (EDC-DZ)

5 Port Solenoid Valve Direct Operated Poppet Type. Specifications

Pilot Operated 2 Port Solenoid Valve for Dry Air

Solutions. We Manufacture. H y d r a u l i c s. Eaton Medium Duty Piston Pump. h y d r a u l i c s

Pilot Operated Directional Control Valves Series D31DW, D31NW, D*1VW

Q max (see specifications table)

Series 581 ISO Pneumatic Directional Control Valves

MCV102A. Pressure Control Servovalve DESCRIPTION FEATURES ORDERING INFORMATION. BLN Issued: October 1998

SD2E-A4. Functional Description. 4/2 Way Solenoid Operated Directional Control Valves Spool Type HA /2012. Replaces HA /2010

Stand alone 4/3, 4/2 solenoid operated directional valve

Eaton EC inch 6-spiral hose

RPE2-04. Functional Description HA /2002. Solenoid Operated Directional Valves. Replaces HA /2000

Electrically Operated Pressure Relief Cartridge, Size 1 Seated Design, Direct Acting Series WUVA 1LO...

EV FT3 ES-FT5 ES/GB :09 Pagina 4 FT3 ES* 4

RPEH4-16. Functional Description HA / /2 and 4/3 Way Directional Control Valves Pilot Operated. Replaces HA /2002

Functional Description

Servo-Performance Proportional Directional Valves with Feedback Pressures to 315 bar (4500 psi) KBSDG4V-5 1* Series

4/3, 4/2 and 3/2 Directional Valve with Wet-pin AC or DC Solenoid

Manual override. Non-locking push type (Tool required) Nil: B: Locking type (Tool required) C: Locking type (Manual) Electrical entry

Transcription:

Solenoid Operated Directional Valve DG4V-3- Design (Soft Shift Design) General Description These solenoid operated directional control valves are for directing and stopping flow at any point in a hydraulic system. The soft shift feature is designed to provide smoother control of actuator acceleration and deceleration than is possible with conventional solenoid valves. The result is minimum hydraulic shock, more reliable systems with longer component life and less downtime. There are options for the soft shift feature: 1. Variable orifice design where you can use an optimized damping orifice tuned to suit your application.. A fixed orifice design, which is non-serviceable and cannot be tuned. Features & Benefits Milled metering notches on the spool enable precise control of flow rate change as the spool is shifted. A P1L - model offers a junction box with rectifier, lights and plug-in coils for quick and easy solenoid changing without removing the valve from the machine. - EATON Solenoid Operated Directional Valve DG4V-3- E-VLVI-SS1-E1 October 15

DG4V-3 Soft Shift Model Series * DG4V-3 * - * *(L) * ** - (**)-(V) M - **** D* (L) - * * - - (P**-A**-B**-T**) 1 3 4 5 7 8 9 1 11 1 13 14 15 1 17 1 Seal Type Blank Viton F Buna Nitrile/High AN Valve Type 4 Solenoid operated V Pressure rating 35 bar(5 psi) on P, A & B ports 3 ISO441 Size 3 3 Performance Blank High performance S Standard performance 4 Spool Type Please refer functional symbols on Page 4 for spool types. 5 Spool Spring Arrangement A Spring offset, end-to-end AL Same as A but left hand build B Spring offset, end to center BL Same as B but left hand build Spring centered N No Spring Detent Orifice Type Variable type 3 Optimized Fixed type High performance only 7 Soft Shift Orifice Size No Orifice 5.5 mm dia. mm dia 7.7 mm dia 8.8 mm dia 9.9 mm dia 1 1. mm dia 11 1.1 mm dia. mm dia 3.3 mm dia *Minimum Orifice Size recommended for high performance type 8 spool 8 Manual Override Blank Override in solenoid end only H Water-resistant override(s) on solenoid end(s) No override in non-solenoid end of single solenoid valves 9 Solenoid Energization Identity Blank None V Solenoid A is at port A end and/ or solenoid B is at port B end, independent of spool type NOTE: Used to select the identification of the solenoid. Refer to table on page 4. 1 Flag Symbol M Electrical options and features 11 oil Type U ISO44, DIN435 connector U1 ISO44 fitted with PG11 plug U ISO44 with fitted DIN plug with lights KU Top exit flying lead (15mm) KUP4 Junior timer (Amp) connector KUP5 Integral Deutsch connector n FW Flying lead with 1/ NPT thread wiring housing FTW Fly. lead wired terminal block & 1/ NPT thread wiring housing FPA3W Fly. lead, 3 Pin connector & 1/ NPT thread wiring housing FPA5W Fly. lead, 5 pin connector & 1/ NPT thread wiring housing X4 Atex approved coil, me type X5 Atex approved coil, d type Also SA and UL approved P1L 1 Surge Suppressor/ Damper Blank No diode D1 diode positive bias D negative bias See Page13 for circuit details 13 Solenoid Indicator Lights Blank No Solenoid indicator lights L Solenoid indicator lights Flying lead coil type only 14 oil Rating B 11V A 5Hz/1V A Hz BL 11V 5 Hz/1V Hz D V A 5 Hz/4V A Hz DS 8V D 3 watt ER 1V A Hz ES 4V A Hz G 1V D GL 1V D H 4V D HL 4V D HM 4V D 8 watt X5 coil type only 15 Tank Pressure Rating Refer to Operating Data for port T pressure ratings. 4 7 bar (1 psi) 5 1 bar (15 psi) for standard performance models, DG4V-3S, with A or D solenoids. 7 bar (3 psi) for A high performance models, DG4V-3, including spool position indicator type S. 7 7 bar (3 psi) for D high performance models, DG4V-3, including spool position indicator type S. X5 coil type only 1 Design Number Basic design 17 Orifice Plug No orifice required 3.3 mm dia.. mm dia. 8.8 mm dia. 9.9 mm dia. 1 1. mm dia. 13 1.3 mm dia. 15 1.5 mm dia.. mm dia. 3.3 mm dia. EATON Solenoid Operated Directional Valve DG4V-3- E-VLVI-SS1-E1 October 15-3

Functional Symbols Spool Options Sol. B P T Sol. A Double solenoid valves, spring centered Double solenoid valves, Single solenoid A valves, B The valve function schematics DG4V-3(S)-*A(V) apply two DG4V-3(S)-*A(V) to position, both U.S. detented and DG4V-3(S)-*AL(V) European DG4V-3(S)-*AL(V) valves. solenoid at port A end Sol. B PA T B Sol. A DG4V-3(S)-*N(V) DG4V-3(S)-*N(V) DG4V-3(S)-*N(V) DG4V-3(S)-*N(V) Double solenoid valves, DG4V-3(S)-*A(V) DG4V-3(S)-*A(V) Single solenoid valves, DG4V-3(S)-*AL(V) two position, detented B Sol. B P T Sol. A Double solenoid valves, spring centered Sol. solenoid B at port PA end T Sol. A Double solenoid Avalves, spring centered Sol. B P T DG4V-3(S)-*(V) DG4V-3(S)-*(V) DG4V-3(S)-*B DG4V-3(S)-*B DG4V-3(S)-*BL DG4V-3(S)-*BL The valve function schematics apply to both U.S. and European valves. DG4V-3(S)-*(V) DG4V-3(S)-*(V) Sol. B P T DG4V-3(S)-*B Sol. A DG4V-3(S)-*B DG4V-3(S)-*BL Transient condition only The valve function schematics apply to both U.S. and European valves. 3 DG4V-3(S)-*N(V) 3 DG4V-3(S)-*A(V) 3 3 3 3 3 3 4 7 7 7 7 35 31 31 317 31 317 31 4 7 4 DG4V-3(S)-*(V) 7 33 33 33 31 33 33 31 35 31 33 33 33 33 DG4V-3(S)-*(V) DG4V-3(S)-*B(V) 33 DG4V-3(S)-8V DG4V-3(S)-8V DG4V-3(S)-8V DG4V-3(S)-8BLV DG4V-3(S)-8BLV DG4V-3(S)-8BV DG4V-3(S)-8BV 5 8 8 8 DG4V-3(S)-8V 8 8 DG4V-3(S)-8BLV 8 8 DG4V-3(S)-8BV 7 7 Sol. B P T Sol. A Transient condition only DG4V-3(S)-*N(V) Double solenoid valves, two position, detented Single solenoid valves solenoid at port A end Transient Single solenoid condition valves, only Sol. solenoid B at port P B Tend P T Sol. The Avalve B function schematics apply to both U.S. DG4V-3(S)-*N(V) DG4V-3(S)-*A(V) P T Sol. A DG4V-3(S)-*A(V) DG4V-3(S)-*AL(V) DG4V-3(S)-*(V) DG4V-3(S)-*B(V) DG4V-3(S)-*BL(V) 51 5 Sol. B P T Single solenoid valves solenoid at port B end DG4V-3(S)-*AL(V) 4 35 DG4V-3(S)-*B(V) 4 DG4V-3(S)-*BL(V) 7 33 517 8 8 8 DG4V-3(S)-8(V) DG4V-3(S)-8BL(V) 7 33 7 33 7 33 8 8 5 Solenoid Identified to US and European Standards 5 51 European solenoid standard 33 5 33 51 33 5 Double solenoid valves, Single solenoid Double European valves, solenoid Solenoid valves, Standard Single solenoid Single valves, solenoid valves, U.S. Solenoid Standard (specify V in the model code) 5 two position, detented 51 solenoid at port two A end position, 5 detented solenoid at port solenoid B end at port A end Double solenoid valves, two position, detented DG4V-3(S)-8(V) ADG4V-3(S)-8BL(V) B DG4V-3(S)-8B(V) 5 51 8 5 8 8 Sol. B P T Sol. A Sol. B PSol. AT P T Sol. P B T Sol. Sol. A A P T Double solenoid valves, spring centered DG4V-3(S)-8(V) Double solenoid A DG4V-3(S)-8BL(V) Bvalves, Double DG4V-3(S)-8B(V) European solenoid standard solenoid valves, spring centered Double solenoid 8 spring centered valves, Single solenoid A Double Bvalves, 8 solenoid valves, Single solenoid Single valves, 8solenoid valves, Single solenoid valves, two position, detented Sol. solenoid A Pat port two TA position, end Sol. detented B solenoid Sol. at port solenoid B B end Pat Aport TA Bend Sol. A solenoid at port B end Single solenoid valves, solenoid at port A end A Sol. B P T B European solenoid standard Sol. A Sol. A P T Sol. B Double solenoid valves, Single solenoid Double valves, solenoid valves, Transient Single solenoid condition Single valves, only solenoid valves, Single solenoid valves, Transient condition only two position, detented Sol. solenoid B at port two P A position, end T Sol. A detented Sol. solenoid B at Sol. port solenoid P AB Tendat port P A TendSol. PB T Sol. solenoid ASol. Aat port P B end T P T Sol. B Single solenoid A valves, B solenoid Double at solenoid port B end Avalves, B A The B valve A function B schematics apply to both U.S. and European valves. spring centered Double solenoid A valves, B spring centered DG4V-3(S)-*N(V) DG4V-3(S)-*A(V) DG4V-3(S)-*AL(V) Sol. B P T Sol. A Sol. B Sol. P A T P T Sol. PB T Sol. ASol. AA PB T P T Sol. B Double solenoid Transient condition valves, only Sol. B PDouble T solenoid Sol. A valves, spring centered Sol. A P T Sol. B Transient condition spring only centered Transient condition only The valve function schematics apply to both U.S. and European valves. Sol. B P T Sol. A Sol. A P T Sol. B Transient condition only DG4V-3(S)-*N(V) DG4V-3(S)-*A(V) 4 DG4V-3(S)-*AL(V) 4-4 EATON Solenoid Operated Directional Transient Valve condition DG4V-3- onlye-vlvi-ss1-e1 October 15 35 The valve function schematics apply to both U.S. and European valves.

Operating Data Response Time Response times are increased over that of a standard solenoid. These times are influenced by flow, pressure, applied solenoid voltage, oil viscosity and ambient temperatures. Response times can be fine tuned to the application by orifices that are interchangeable via the manual actuator in the solenoid end. See model code for available orifices. Response times shown are for a type spool at a system pressure of 1 bar (3 psi), flow at 19 L/min (5 USgpm), solenoid voltage at 1% of rating and 38º (1º F) oil temperature. Times are determined from the instant of power on/off to the point of maximum cylinder velocity (shift) or the end of cylinder movement (spring return). All times are without arc suppression diodes. Spring return times can be expected to increase with diodes in place. Response times greater than 7 msec are not recommended. NOTE: For the high performance type 8 model, core tube orifice sizes smaller than. mm diameter are not recommended. For Variable Orifice() Orifice Response Times olor Diameter Shift Spring ode mm (ms) Return (ms),7 5 55 Green,8 4 375 Blue,9 5 5 Purple Response times for spools other than the spool are similar and are system dependent. For Fixed Orifice(3) Response Times Shift Shift (ms) Return (ms) 4 175 Response times for spools other than the spool are similar and are system dependent. Orifice hanging Procedure WARNING 1. Before breaking a circuit connection make certain that power is off and system pressure has been released. Lower all vertical cylinders, discharge accumulators and block any load whose movement could generate pressure. Plug all removed units and cap all lines to prevent entry of dirt into the system.. Using a 5/3 hex key, remove manual actuator plug and spring from the end of solenoid (Tightening torque. 7.3 N.m 55 5 lbf.in.) 3. Insert extraction tool (878495) into solenoid via the manual actuator opening. Rotate tool until aligned and push pin into slot in armature. 4. Using 1/ wrench and tool to prevent the armature from rotating, insert 3/3 hex key down the center of tool and remove orifice plug. 5. Replace by the same method, tightening orifice snug to ensure bottoming of threads. Smaller orifices increase response times, larger orifices decrease response time. Orifice & Tool Kit -1411 For fine tuning shift performance, orifices must be ordered separately. The kit includes () each of.7,.8 &.9 mm dia. orifices, (1) installation tool, (1) 5/3 hex key and (1) 3/3 hex key. Manual actuator 111.1 (4.37) Dimension required to remove orifice 878495 extraction tool 3 /3 wrench EATON Solenoid Operated Directional Valve DG4V-3- E-VLVI-SS1-E1 October 15-5

Operating Data Solenoid Identified to US and European Standards Feature DG4V-3 DG4V-3S Pressure Limits P, A and B ports 35 bar (575 psi) 35 bar (575 psi) T port: 1 bar (345 psi) 1 bar (145 psi) Flow rating See performance data See performance data Relative duty factor ontinuous; ED = 1% ontinuous; ED = 1% Type of protection: ISO 44 coils with plug fitted correctly IE 144 class IP5 IE 144 class IP5 oil winding lass H lass H Lead wires (coils type F***) lass H lass H oil encapsulation lass F lass F Permissable voltage fluctuation: Maximum Refer to temperature limits. Refer to temperature limits. Minimum 9% rated 9% rated Typical response times at 1% rated volts measured from application/removal of voltage to full spool displacement of spool at: Flow rate P-A, B-T 4 l/min (1. USgpm) l/min (5.3 USgpm) Pressure 175 bar (537 psi) 175 bar (537 psi) D (=) energizing 45 ms ms D (=) de energizing 8 ms 4 ms Power consumption, D solenoids at rated voltage and (8 F). Full power coils: 1V, model type G 3W 3W 4V, model type H 3W 3W For applications where valves are to remain pressurized (either energized or de-energized) at pressures over 1 bar (345 psi) without frequent switching, it is recommended to use the high performance model, DG4V-3. 1 st half cycle; armature fully retracted. - EATON Solenoid Operated Directional Valve DG4V-3- E-VLVI-SS1-E1 October 15

Performance Data Typical with mineral oil at 3 cst (18. SUS) and a specific gravity of.87. Maximum flow rates Performance based on full power solenoid coils warm and operating at 9% rated voltage. See note at bottom of next page when using low power coils (DG4V-3 models only). Flow - USgpm 4 8 1 1 14 1 18 35 3 5 5 3 4 5 3 1 5 4 Pressure - bar 15 3 Pressure - psid 1 5 4 1 1 3 4 Flow - l/min. 5 7 8 Spool Type urve Number 1 1 3 8 5 31 33 3 A 4 EATON Solenoid Operated Directional Valve DG4V-3- E-VLVI-SS1-E1 October 15-7

Pressure Drop - bar psi Performance Data Pressure Drop urves Flow - USgpm 18 4 8 1 1 14 1 18 8 7 4 75 5 1 5 5 14 3 1 175 Pressure Drop - 1 8 1 15 15 1 75 4 5 5 1 3 4 5 7 8 Flow - l/min. Spool Type Pressure Drop urve Reference hart Spring entered P--T P-B A-T + 5 1 5 1 5 4 5 4 1 1 8 + 5 3 5 3 3 5 4 5 1 31 * 5 1 5 4 33 * 3 Spring Offset P--T P-B A-T A 7 5 8 5 For any other viscosity the pressure drop (ΔP) will change as follows: Viscosity(s) cst 14 3 43 54 5 7 87 (SUS) (75) (15) () (5) (3) (35) (4) % of ΔP (Approximate) 93 111 119 1 13 137 141-8 EATON Solenoid Operated Directional Valve DG4V-3- E-VLVI-SS1-E1 October 15

Installation Dimensions Models for use with ISO 44 (DIN 435) connectors 3rd angle projection Double solenoid models Single solenoid models DG4V-3(S)-*-**-(V)M-U-**- DG4V-3(S)-*N-**-(V)M-U-**- DG4V-3(S)-*A(-**) DG4V-3(S)-*B(-**) DG4V-3(S)-8BL(-**) As shown DG4V-3(S)-*AL(-**) DG4V-3(S)-*BL(-**) DG4V-3(S)-8B(-**) Solenoid and end cap interchanged 1, (4.) 87, (3.4) D 74, (.91) oil types: U (shown), KU, SP1, and SP (see Model ode) 53, (.1) Alternative plug positions by loosening knurled nut, turning coil, and re-tightening. 5, (.98), coil 1,75 length (.8) B (single solenoid model) A (double solenoid model) 4, (.94) 48, (1.88) Port A Port T Port P Port B Not applicable to type 8 spool. an vary dependent on source of plug. Dimensions in mm(in). Model type A or D A Dim. B Dim. Dim. D Dim. All D= (8.) 15 (.1 4) 1 (.5) 73 (.87) DG4V-3 A~ (7.87) 14 (5.75) 51 (.1) 3 (.48) DG4V-3S A~ (7.87) 14 (5.75) 45 (1.7) 3 (.48) oil onnectors U/U1/U KU KUP4 KUP5 X4 X5 EATON Solenoid Operated Directional Valve DG4V-3- E-VLVI-SS1-E1 October 15-9

Installation Dimensions DG4V-3 - *****-M-P1L-DJH5- Plug-in oil Millimeters (inches) Ground screw Power connection for this coil Rectified conduit box input voltage: 11-1 V 5- Hz Power connection for this coil 47, (1.85) 14, (4.9) 31,8 (1.5) onduit connection G 1/ or 1/ NPT 1,8 (.88) 75,7 (.98) 91,8 (3.1) A" B" -1 EATON Solenoid Operated Directional Valve DG4V-3- E-VLVI-SS1-E1 October 15

Installation Dimensions Models with F type coils (lead wires) and conduit box. Double solenoid models Single solenoid models DG4V-3(S)-*-**-(V)M-F-**- DG4V-3(S)-*N-**-(V)M-F-**- DG4V-3(S)-*A(-**) DG4V-3(S)-*B(-**) DG4V-3(S)-8BL(-**) As shown DG4V-3(S)-*AL(-**) DG4V-3(S)-*BL(-**) DG4V-3(S)-8B(-**) Solenoid and end cap interchanged A (double solenoid models) B (single solenoid models) *J &* W conduit boxes Thread connection W NPT J M 1.5-8H 5, (.) 5, (.98) 1,75 (.8) Ground connection 4, (.1 dia.) self tapping screw coil length D 47 (1.85) 74, (.91) 3, (.1) 91, (3.57) 8,75 (.71) 53, (.1) Two lead wires per solenoid with M3 size terminals for customer connections 4, (.94) 48, (1.88) Port A Port T Port P Port B * 89 (3.5) for FPB J & W conduit boxes 14 (4.) All plug-in conduit boxes Dimensions in mm(in). Model type A or D A Dim. B Dim. Dim. D Dim. All D= (8.) 15,5 (.14) 1 (.5) 73 (.87) DG4V-3 A~ (7.87) 14,5 (5.75) 51 (.1) 3 (.48) DG4V-3S A~ (7.87) 14,5 (5.75) 45 (1.7) 3 (.48) odes "FW" : lead wires for each solenoid, approximately 15, (.) long. M3 (#) terminals provided for customer connection. odes"ftw" : Valve supplied with lead wires connected into terminal strip suitable for M3 (#) terminals for customer connection. EATON Solenoid Operated Directional Valve DG4V-3- E-VLVI-SS1-E1 October 15-11

Electrical Plugs and onnectors Terminal strip and lights For valves with type F coils. Terminal strip (part number 89345) clips to cover and can be field-fitted M3 x,5-h screws (part number 18) each end onduit box cover and nameplate complete with sealing gasket and 4 screws 4 terminal screws M3 x,5-h (part number -113355) onnections to solenoid A (or B, according to model type) Light assembly is held in place by end pair of M3 screws; can be fitted to terminal strip. 8,5 (1.1) 3, (1.18) onnections to solenoid B (or A, according to model type) 1. For D coils the +ve lead(s) must be connected to the terminal(s) marked +. When using 3-wire incoming leads to double Anti-rotation tab ensures correct orientation of cover Rubber gasket to junction box lenses in cover solenoid valves (i.e. common neutral) the inner pair of terminals must be interconnected.. For correct light indication of energized solenoid ensure that solenoid leads are correctly connected: light terminals are common with each outer pair of solenoid terminals according to the side with + mark. Insta-Plug DG4V-3(S) FPA DG4V-3(S) FPBW Eaton -part "Insta-Plug" eliminates breaking electrical inputs for valve disconnect. A male half is pre-wired to the valve body. The mating PA configuration 71,1 (.8) 1,5 (.4) 3,5 (1.8) Port A Dimensions in mm(in).,5 (.79) 15,5 (.1) Port B plug is inside a wire housing with external terminals for machine wire connections. aptive thumb screws, when loosened, permit the wire housing to be pulled clear of the valve for disconnect. A longer ground post provides first make/last break ground connection. 47,5 (1.87) ref. M4-H thd. DIN 435 onnector able diameter range: Wire section range: Terminals: Type of protection: onnector can be positioned at 9 intervals on valve by re-assembling contact holder into appropriate position inside connector housing. onnectors with and without indicator lights are available (order separately): Use U1 or 51(.1) U11 type connectors with 1 and 184V sq. D coils 7 if rectification is (.71) (1.) required. onnectors 98,5 with and without 1,5 (3.88) Seal indicator lights are available (.) (order separately): M3 thread 3,5 sq. 5,5 (1.) (.) Ø-1 mm (.4-.4) Ø,5-1,5 mm (.8-.3 in) Screw type IE144 class IP5, when plugs are fitted correctly to the valves with interface seals (supplied with plugs) in place. Use U1 or 51(.1) U11 type connectors with 1 and 184V sq. D coils 7 if rectification is (.71) (1.) required. onnectors 98,5 with and without 1,5 (3.88) Seal indicator lights are available (.) (order separately): M3 thread 3,5 sq. 5,5 (1.) (.) U11 Rectified 1 D coils WARNING with TAG 4 D lights Electrical power98-4 VD must be -4 VD disconnected 7,5,5 U1 before (1.8) Rectified removing or (1.4) coils replacing without this,5 lights receptacle. (.88) -1 EATON Solenoid Operated Directional Valve DG4V-3- E-VLVI-SS1-E1 October 15

Electrical Plugs and onnectors NFPA onnector T3.5.9-198 DG4V-3(S) FPA3W(L)-**- DG4V-3(S) FPA5W(L)-**- The receptacle is a standard three or five pole connector with shortened leads and terminals added. The five pole plug has four leads 11, (4.) long and one 177,8 (7.).875-1UN-A thd. 1, (.) long. The three pole plug has two leads 11, (4.) long and one 177,8 (7.). All wires have underwriters recognized non-solder insulated eyelet terminals. The green wire is used for the ground (earth) connection (No. 8 screw furnished). Valves are supplied pre-wired. onnection details and model type/model code references Warning tag: Electrical power must be disconnected before removing or replacing electrical plug. 3 pin connector Use with single solenoid valve Key model code designations: DG4V-3(S)-*A(L)(-**)-(V)M- FPA3W(L) DG4V-3(S)-*B(L)(-**)-(V)M- FPA3W(L) 1 green lead (ground) 1 3 lead to solenoid 3 lead to solenoid 5,4 (1.) hex (reference all types) 5 pin connector Use with single solenoid valve Key model code designations: DG4V-3(S)-*A(L)(-**)-(V)M- FPA5W(L) DG4V-3(S)-*B(L)(-**)-(V)M- FPA5W(L) 1 lead to solenoid 5 1 4 3 5 lead to solenoid 4 lead capped 3 green lead (ground) lead capped 5 pin connector 5 pin connector 8,75 (.71) Surge Suppression Devices (For D Valves) Standard diode (D1), (D) Diode in parallel with coil, positive bias. When switch (S1) is opened, the energy stored in the coil is trapped and dissipated by the diode (D1), (D). Works only with D voltage Polarity dependent Increase drop out time oil Surge Suppression Devices (For D Valves) Standard diode (D) Diode in parallel with coil, negative bias. When switch (S1) is opened, the energy stored in the coil is trapped and dissipated by the diode (D). Works only with D voltage Polarity dependent Increase drop out time oil Use with double solenoid valve Key model code designations: DG4V-3-*/N(L)(-**)-(V)M-S4- FPA5W(L) Note: These surge suppression devices are Polarity Dependent. Proper biasing conditions must be met when installing/connecting a coil in a system. Times represent cessation/application of voltage to coil versus velocity (start/stop) of a cylinder using a single solenoid, spring offset valve (time in milliseconds). Valve Shift and Dropout Times with and without Surge Suppression Shift Dropout ETOP 3 Do Diode 3 Diode Alone 3 131 Use with single solenoid valve with S3 spool position monitor switch Key model code designations: DG4V-3-*A(L)(-**)-(V)M-S3- FPA5W(L) D 1 S 1 (No ) D S 1 (No ) (No 1) (No 1) EATON Solenoid Operated Directional Valve DG4V-3- E-VLVI-SS1-E1 October 15-13

Eaton Hydraulics Business USA 1415 Lone Oak Road Eden Prairie, MN 55344 USA Tel: 95-937-98 Fax: 95-94-77 www.eaton.com/hydraulics Eaton Hydraulics Business Europe Route de la Longeraie 7 111 Morges Switzerland Tel: +41 () 1 811 4 Fax: +41 () 1 811 41 Eaton Hydraulics Group Asia Pacific Eaton Building 4 th Floor, No. 3 Lane 8 Linhong Rd. hangning District Shanghai 335 hina Tel: (+8 1) 5 99 Fax: (+8 1) 5 4 15 Eaton All Rights Reserved Printed in USA Document No. E-VLVI-SS1-E1 October 15