esure Rectifiers and NetSure DC Power Systems Krunoslav Štibi May 30thth, 2012

Similar documents
DC Power for Business-Critical Continuity. The Regional DC Power System with Global Muscle, -48 V DC, 3 153,6 kw

MKN-DSP SERIES - THREE PHASE

Offshore and process industry Safety and Automation Systems (SAS) Marine Communication systems onboard ships. Railway & Metro infrastructure

Symmetra PX 250/500. Scalable from 100 kva kw to 500 kw, parallel capable up to 2,000 kw

kVA. Liebert NX. Enterprise-Scale UPS Protection For Medium And Large Data Centers

NetSure 701 Series DC Power System. DC Power for Business-Critical Continuity

Features and Benefits

Emerson Network Power

NetSure 701 Series DC Power System. DC Power for Business-Critical Continuity

BATTERY FREE DC ENERGY STORAGE FOR UPS. Yorba Linda CA (714)

off-grid Solutions Security of supply Basics: Off-grid energy supply

Symmetra PX 100 kw. Scalable from 10 kw to 100 kw Modular, scalable, high-efficiency power protection for data centers

NterpriseIP Solution Adaptive, high-availability power system for IP Telephony. Business-Critical Continuity for Communications

D Series: UPS UPTO - 300KVA - Three / Three Phase

NetSure. 211 Series DC Power System

ENERGY SOLUTIONS RESIDENTIAL STORAGE BATTERY SYSTEM

W Datasheet: UPS AVARA Modular kVA (1-8 x 15kvA)

Series. On-line, Single-phase Parallel Redundant UPS System. 6 and 10 kva Rack Mount. Your Tailored Power Solutions Provider TM

Est FlexiPower Mini UPS FPX Mini kVA

PowerWave 33 Efficient power protection for today s IT and process-related work environments

Modular UPS «AGIL» Stay on! Changing the rules for critical business continuity :

Three-phase UPS system DPA UPScale ST kw The modular UPS designed for lowand medium-power applications

Symmetra PX 96/160. Scalable from 16 kw to 160 kw Modular, scalable, high-efficiency power protection for data centers

Series. Full Three Year Warranty. On-line, Single-phase Parallel Redundant UPS System. 6 and 10 kva Tower. Your Tailored Power Solutions Provider TM

KEOR HP. THREE-PHASE UPS from 100 to 800 kva GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

NetSure 5100 ORDERING GUIDE. 48V & 24V DC Power System (40 A to 600 A)

DPA 250 S4 (50 kw 1,500 kw) The most energy-lean UPS on the market MODULAR THREE-PHASE UPS SYSTEMS. The most energy-lean UPS on the market

KEOR HP. THREE-PHASE UPS from 100 to 800 kva GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

Symmetra PX. Industry-leading efficiency, availability, and performance for small, medium, and large data centers and mission critical environments

ABB Data Center Solutions Day 5 July 2013 by Kelvin Sim Myths or Truths: Achieving 99% Efficiency with Single Conversion Backup Power System

ABB UPS 3. November 2014

Stand-Alone-Systems POWERFUL TECHNOLOGY

Standard 1000VA, 2000VA & 3000VA Universal Tower/Rack Mount LB Extended Models 900VA, 1700VA & 2500VA

TO BOTTOM-LINE BENEFITS

Series 120/120VAC Universal Tower/Rack Mount

INVERTER. MECHANICAL DATA Steel with powder paint Dimension (mm) 527 x 228 x 190 Net Weight (kgs) 18 STANDAR. Cont output power at 20ºC. Cos φ 0.

Three-phase UPS system. DPA UPScale ST kw Best-in-class modular UPS for maximum availability

Battery Monitoring Why Technology Matters. Mats Karlstrom V.P. Sales & Marketing, Alber

Power+ CLASSIC. 20/30 kva, 3x208 Vac

Model ESV Uninterruptible Power System 1.5 KVA/KW KVA/KW Single Phase

TRIMOD HE UPS. MODULAR THREE-PHASE UPS from 10 to 80 kw THE GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

TECHNICAL DATA SHEET KVA UPS Systemss

UPS Multi Power 1-28 x 42 kw up to 1MW

True Fail-Safe Technology and Precision Control for Reliable Shutdown

Phase Modular Finally the benefits of Modular ups are for all

YOUR POWER IN SAFE HANDS. E Series UPS

Liebert NX TM. 250kVA kVA Transformer-free. High Efficiency, Scalable On-line UPS

On-line, Single Phase, Double Conversion UPS

POWER+ CLASSIC 20/30 KVA, 3X208 VAC WITH INTERNAL BATTERIES. GAMATRONIC, A SolarEdge Division

POWER+ CLASSIC 20/30 KVA, 3X208 VAC WITH INTERNAL BATTERIES. GAMATRONIC, A SolarEdge Division

There s a new power in Solar 1500V ultra-high power string inverters for utility-scale PV applications

SOLAR SMART. 12/24V 20Amp MPPT Solar Charge controller with Ethernet

Technical Specifications. Sentinel PRO 700 VA up to 3000 VA 1000 VA ER-2200 VA ER-3300 VA ER

Compact Energy Storage Module. Modular Systems, EPDS. Product overview

Symmetra PX. Symmetra PX250/500kW Scalable from 25kW to 500kW Parallel-capable up to 2000kW

HYBRID POWER FOR TELECOM SITES

Huawei Network Energy, Powering the Future. Huawei UPS Solutions HUAWEI TECHNOLOGIES CO., LTD.

STAND- ALONE -SYSTEMS

Special Specification 6058 Battery Back-Up System for Signal Cabinets

SPECIFICATIONS UPS Triple Output 13.6VDC/213W, 48VDC/153W, 48VDC/39W

UniStar III Series. Full Three Year Warranty. On-line, Single-phase UPS System. 1, 2, & 3kVA Tower Model

ABB solar inverters Product portfolio

INTELEPOWER CX COMMUNICATIONS SYSTEMS

ASPIRO & GUARDIAN BATTERY MANAGEMENT WITH ACC EXTENDED CONTROLLER

Engineered power. Inverter-chargers. Inverters. MPPT solar charge controllers. Battery chargers. Battery monitoring.

POWER+ PREMIUM CBS. BS-EN Emergency electrical installations Electric power systems Emergency lighting Escape lighting

CPS2000 Cabinet Power System

Plug Into the Current Future

Plug Into the Current Future

Liebert Hipulse E The High-ECO-Availability UPS. AC Power Systems

Lithium-ion battery systems for ABB UPS solutions Reliable, lightweight and compact UPS energy storage for critical applications

PowerOasis GPM Accra. John O Donohue Nov 2012

3ph UPS NS3000 series kVA

Defender Mini Online Emergency Central Lighting Inverter (CLI) Technical Specifications

APC Smart-UPS. GUIDE SPECIFICATIONS FOR 1000VA & 2000VA Smart-UPS 230VAC Uninterruptible Power Supply

Cellwatch Battery Monitoring Systems

Liebert NXC. 10kVA - 60kVA. Compact, Efficient, and Reliable Power Solution

ENERGY SOLUTIONS RESIDENTIAL STORAGE BATTERY SYSTEM

UPS5000-E (25-75 kva) Series

Fortress 3 Harsh. Harsh Environment. Emergency Central Lighting Inverter (CLI) Technical Specifications

DIN-Rail DC UPS. Powers Loads and Charges Back-Up Battery, Ideal for Automation and Wireless System Transmitter Applications

Microgrids Outback Power Technologies

596 Rectifier Retrofit

AT EVO SERIES BATTERY CHARGER

UPS UNINTERRUPTIBLE POWER SUPPLY GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

Galaxy VM. From 160 kva to 1000 kva. Three-phase power protection. Galaxy VM trusted partner for your business continuity. schneider-electric.

OSC is your electric meter expert. When you have questions or need assistance in selecting the proper meter for the job, call us!

"EH SERIES" POWER SUPPLIES "PS SERIES" POWER SUPPLIES EH SERIES PUBLIC SAFETY POWER SUPPLIES PS SERIES PUBLIC SAFETY POWER SUPPLIES

Availability secured. For Railway, trackside and infrastructure Systems

Energy Storage and Other Energy Control Solutions

Power Safety. Protect 8. Industrial UPS. Protect 8.31 Single Phase output 10 kva 120 kva. Protect 8.33 Three Phase output 10 kva 120 kva

MASTERYS IP+ 10 to 80 kva

SmartOnline S3MX Series 3-Phase 380/400/415V 60kVA 54kW On-Line Double-Conversion UPS

Keatec Energy Catalogue 2018 Telecommunications

Power Protection Discrete Automation & Motion South Africa

Expect More From An Energy Storage Solution BATTERY FREE DC ENERGY STORAGE FOR UPS BILL WOLFE NORTHEAST REGIONAL MANAGER

magellan commercial UPS solutions Magellan Power Modular - Flexible UPS

Charge up in Control MENNEKES Load Management. Intelligent charge and load management for operational safety and cost control

MGE TM Galaxy TM 7000

Aurora Single Phase Emergency Lighting Inverters

Transcription:

esure Rectifiers and NetSure DC Power Systems Krunoslav Štibi May 30thth, 2012

What are your site challenges?..continuous secure operation of critical equipment?..to limit your operational costs in the increasingly competitive environment?..to reduce your energy costs and carbon footprint?..unpredictable network expansion needs? 2

NetSure Series The Most Reliable Rectifiers in the World Chloride SAED Ericsson Actura Huawei Avansys / PS Nortel Candeo Marconi Vortex/Lorain > 300 Years of cumulative experience! 3

NetSure Series The Most Reliable Rectifiers in the World Uncompromised Reliability Over two million units operating today Less than 0.5% return rate Type Market Launched Qty in operation Return rate Rectifiers Global 2004-2011 >2 000 000 1 <0.5% R48-500/1000 Thru Aug 2010 R48-2000 R48-2000e R48-3200 R48-3500e R48-5800 5800W 500/1000W 2000W 2000W 3200W 3500W 1) All data provided are based on rectifiers returned to Emerson. Field failure statistics can't be applied on a specific region, site, project, contract or customer. It should be seen as information only and performance up until specified date, not a warranty or prediction about future performance or expectations 4

esure Rectifier The most Efficient Rectifier in the world Best in class sustained efficiency throughout a wide range of operating conditions Efficiencies approaching 97% between 30% through 70% load reduced energy consumption and CO2 emissions Single year payback 5

Energy Savings Case study: esure vs standard efficiency Scenario: At list price, a customer chooses to buy 1000 x 3200W esure rectifiers vs standard efficiency (SE) rectifiers At 60% load, the efficiency of the esure is 96.7% compared to 92% for SE rectifiers Assumptions: Energy cost is $0.1 per KWh Rectifiers run at 60% load Air Condition unit has EER rating of 10 and runs at 8 hours per day 0.60kg CO2 emission per KWh consumed Challenge: What is the energy cost of ownership over a 10 year useful life of an esure rectifier vs. a standard efficiency rectifier? 6

Cost Benefit Case study: esure vs standard efficiency Energy loss cost for 1000 standard efficiency rectifiers @ 92% efficiency Year 1 2 3 4 5 6 7 8 9 10 AC energy loss 166MW 166MW 166MW 166MW 166MW 166MW 166MW 166MW 166MW 166MW SE Rect energy loss Total energy loss 1463MW 1463MW 1463MW 1463MW 1463MW 1463MW 1463MW 1463MW 1463MW 1463MW 1629MW 1629MW 1629MW 1629MW 1629MW 1629MW 1629MW 1629MW 1629MW 1629MW CO2 emission 977Mg 977Mg 977Mg 977Mg 977Mg 977Mg 977Mg 977Mg 977Mg 977Mg Annual cost of energy loss $162 900 $162 900 $162 900 $162 900 $162 900 $162 900 $162 900 $162 900 $162 900 $162 900 Grand Total: $1 629 000 9770 metric tons CO2 Energy loss cost for 1000 esure rectifiers @ 96.5% efficiency Year 1 2 3 4 5 6 7 8 9 10 AC energy loss 69MW 69MW 69MW 69MW 69MW 69MW 69MW 69MW 69MW 69MW esure energy loss 610MW 610MW 610MW 610MW 610MW 610MW 610MW 610MW 610MW 610MW Total energy loss 679MW 679MW 679MW 679MW 679MW 679MW 679MW 679MW 679MW 679MW CO2 emission 407Mg 407Mg 407Mg 407Mg 407Mg 407Mg 407Mg 407Mg 407Mg 407Mg Annual cost of energy loss $67 900 $67 900 $67 900 $67 900 $67 900 $67 900 $67 900 $67 900 $67 900 $67 900 1.26 year payback 78% ROI on esure premium Grand Total: $679 000 4070 metric tons CO2 Energy loss reduced by 58% with esure vs. standard product lines! 7

esure Annual savings per 8 kw site 25% load kw Efficiency kw 0 R48-2000 2,2 90,6% 2 1 R48-2000e 2,1 95,7% 2 Watt 208 90 $1) 182 79 per Year 103 50% load Input kw 0 R48-2000 1 R48-2000e 75% load Input kw 0 R48-2000 1 R48-2000e 100% load Input kw 0 R48-2000 1 R48-2000e 4,3 4,1 6,5 6,3 8,8 8,4 Rectifier Load Efficiency kw 92,3% 96,5% Rectifier Load Efficiency kw 92,1% 96,0% Rectifier Load Efficiency kw 91,2% 95,4% Losses Watt 1) $ 4 334 4 145 Losses Watt 1) $ 6 515 6 250 Losses Watt 1) $ 8 772 8 386 292 127 451 219 676 338 Savings per Year 165 Savings per Year 232 Savings per Year 338 1) @ 0,10 /kwh 8

Efficiency Cost Impact Case study: esure vs standard efficiency 9

DC Power Systems Leading global manufacturer of -48V network power systems Modular system architecture facilitates optimal investments Low installation and commissioning cost with pre-assembled and pre-tested units NetSure DC power systems provide technology platform of indoor and outdoor integrated systems Industry-leading reliability (return rate of < 0.5%) with over 2M units deployed Near 97% efficiency with esure rectifiers Products NetSure 211 Mini systems NetSure 501 Small systems NetSure 701 Medium systems NetSure 801 Large systems 10

NetSure 211 Mini systems

NetSure 211 Series Our most compact DC Power system, targeted for street cabinet applications. Also suitable for integration in any outdoor enclosure, shelter or cabinet solution thanks to its high power density and efficiency levels greater than 92%. 500W or 1000W plug-n-play rectifiers Up to 6kW / -48V power system Standard or advanced controller 1U or 2U high power shelf Fits in 300mm ETSI cabinet Space for 1-2 rectifiers (500 or 1000W) Circuit breakers are standard in most configurations Easily accessible, plug-in design with front cable terminations Wide operating temperature range -40 to +75 C Rectifier efficiency >92% 19 Space for 1-4 rectifiers (500 or 1000W) 23 Space for 1-6 rectifiers 19 Space for 1-4 rectifiers (500 or 1000W) 12

NetSure 211 Rectifier R48-1000 Maximum Output Power: 500W, 1000W High efficiency, >92% (R48-1000) Wide input voltage range (85-300 VAC ) Wide temperature operating range (-40 to +75 deg C) EMC, (EN 300 386:2001) Class B Dimension: 2 x 1 U, Fits in ETSI 300 13

NetSure 501 Small systems

NetSure 501 Series A highly flexible DC Power system for all types of access applications, available as cabinets or compact, cost-effective subrack solutions. 2000W plug-n-play rectifiers, available as standard or esure rectifiers with 96.5% efficiency Up to 24 kw / -48V system Available as Subrack (from 3U high) Wall-mounted or battery rack-mounted Standalone cabinet Standard or advanced controller Front access (cable exit front or up) High power density Wide AC input range, single phase (85-300 VAC) Wide operating temperature range: -40 to 75º C 15

NetSure 501 Series Available in many different shapes Subrack 19 or 23 wide <400mm deep Suitable for embedded applications Hardtop 23 wide 400 mm deep 4U, 7U, 9U, 13U high Wall- or battery-rack mounted Stand-alone cabinet 23 wide 400mm or 600mm deep 1200 mm 2200 mm high With or without doors Earthquake proof cabinets as options Suitable for different numbers and sizes of batteries 16

esure R48-2000e High efficiency In industry top segment with 96.5% efficiency Fully backwards compatible Highest reliability Nearly 2M NetSure rectifiers deployed with a return rate of >0.5% Highest temperature rating Full power at 55 degrees C 1500W @ 75 degrees C esure R48-2000e Efficiency Without Compromise 17

NetSure 701 Medium and Large Systems

esure High-Efficiency Technology The most efficient rectifier in the world Near 97% efficiency for loads at 30% - 70% Backwards compatible with existing NetSure DC Power Systems The most reliable rectifier in the world NetSure world-class reliability: Nearly 2M units deployed with a return rate of <0.5% esure R48-3500e Efficiency Without Compromise 19

NetSure 701 Series The most efficient DC power system with rectifier efficiency near 97%. A modular system available in distributed and bulk configurations. 3200W plug-n-play rectifiers, available as standard or 3500w esure rectifiers with efficiency near 97% System capacity 840 kw (16000A) High power density systems with up to 126 kw per cabinet System available in distributed or bulk configuration Top or bottom cabled Configurations with batteries included in main cabinet obtainable High and low ohmic DC distribution alternatives 20

NetSure 701 Series NetSure 701 The Family One platform for various network infrastructure needs, the NetSure 701 Series is available as: NetSure systems for retrofit applications Single cabinet systems including batteries Multi Cabinets Bulk- and semi bulk systems with separate distribution NetSure systems for AC/DC applications Suitable for applications up to 840kW of installed power 21

NetSure Semi-Bulk system A Semi-bulk system consists of one or several cabinets with both power and distribution. Each cabinet includes: Up to 24x3500W rectifiers per cabinet for NetSure 701 Advanced Control Unit (ACU+) AC circuit breakers A battery unit (BU) including 4 x NH3 fuses (up to 630A) for battery connections, a BLVD with automatic reconnection and a shunt Two different types of distribution units (DU) (both units available with 1 load shunt per DU as option): 5 x NH3 (up to 630A) unit for large DC load connections Circuit breaker unit for small DC load connections (LOD or HOD) Cabinet dimensions are 2000 x 600 x 600 mm 22

NetSure 701 Series NetSure for AC and DC applications A compact and space saving solution with NetSure rectifiers and integrated TSI inverters Transfer time reduced to zero Easier and more cost efficient installation compared to separate systems for AC and DC Fully tested integrated solutions Near 96% system efficiency with 2500VA inverters and esure rectifiers Choice of 750VA or 2500VA TSI inverters Suitable for applications where reliable power for both DC and AC loads is required 23

NetSure 801 Uninterruptible power at its best!

NetSure 801 Series A reliable DC Power system with 3-phase rectifiers for large power -48VDC sites. NetSure 801 is available as distributed and bulk configurations. 5800W rectifiers (only 8 kg) 3-phase rectifiers System capacity up to 1,4MW (28800A) High power density Up to 8 rectifiers (46.4 kw) per cabinet for distributed system Up to 20 rectifiers (116 kw) per cabinet for bulk system Rectifier efficiency 93% Advanced controller unit as standard Top and bottom cabled configurations available High and low ohmic DC distribution alternatives Quick and easy extension New cabinets can be added to a live system Rectifiers and distribution units can be added in a live system 25

NetSure 801 Rectifier, R48-5800 380/480Vac, 3-phase Input Voltage Output Power 5800 Watt High Power Density: Low profile: 2U height Rack power density: 5800W/RU Module power density: >800W/dm3 Wide Input Voltage Range, 260-530 VAC R48-5800 High Efficiency, 93% Low THD, < 5 % Weight: < 8.0 kg New esure, 96% efficient rectifier will be launched in June 2012! 26

NetSure 701 Series NetSure for retrofit applications Innovative solution to upgrade and expand an existing power system for increased reliability and boosted performance Keep existing infrastructure (cabinet, distribution, cabling etc) Old rectifiers removed, replaced with retrofit subrack: New rectifiers New controller Distribution and battery connection if needed (optional) Reliable new technology at a lower cost compared to investing in a complete new system Increased system efficiency (up to 96% system efficiency with esure rectifiers) Install systems live without service interruption Eliminate expensive and problematic rectifier legacy support issues Gain access to new functionalities via the ACU+ 27

Increased system efficiency Legacy System 4,7kW energy loss 29,7kW @ 84% average rectifier efficiency System retrofitted with esure rectifiers 0,97kW energy loss 25,9 kw @ 96,5% average rectifier efficiency Output power 25kW 80% reduction of energy losses! Normally <2 years pay back! (based on DC savings only, additional savings in cooling) 28

Controllers

SCU+ Controller - Common Features Advanced battery management Temperature controlled charging Boost charging Battery discharge test Battery capacity prediction Battery current limitation Advanced alarm monitoring Programmable severity setting Alarm log (200 last entries) Programmable alarm grouping & relay activation Local language support System voltage setting & management Support for 2 LVD (mono- or bi-stable) Web/SNMP option ECO mode support Setting file definition, upload and remote download Firmware remote downloading Connection of Extension Boards Remote monitoring 30

ACU+ Controller Advanced battery management including battery capacity prediction ECO mode advanced energy savings function Remote control connections/protocols including web & SNMP 2 analog inputs for temperature sensors Remote and onsite download & upload of configuration file and firmware Supports master/slave & power split functionality for system expansion Connection of site monitoring units for management of other equipment (SM BAT, SM AC, SM IO) Local language support 31

Advanced Battery Management Temperature compensation Automatic battery test End test by voltage/time/capacity Scheduled battery test (up to 12 times) Constant-current discharge test results in higher precision Cyclic Short Test exposes battery trouble timely What is Short Test? A cyclic short discharge of battery, e.g. 5 minutes, can be enabled via local or remote settings. The controller will detect the current difference between two battery strings during the discharge. If the difference is bigger that a set value, an alarm will be triggered to show possible trouble in battery. 32

ECO Mode - Energy Optimization Function A patented energy optimization software Boosts the efficiency of already installed NetSure systems by simply replacing some standard efficiency rectifiers with esure rectifiers Original system with standard efficiency rectifiers System upgraded with esure high efficiency rectifiers required for normal load ECO Mode: at normal load the esure rectifiers run, standard efficiency rectifiers in standby for redundancy. 33

Controll and Monitoring An advanced controller enables: Enhances monitoring locally: Advanced battery management Advanced energy saving functions Site monitoring Web and SNMP support TCP/IP Enables possibility for remote monitoring Reports and Statistics Remote or local software upgrade 34

Monitoring an enabler for efficiency Provide information about site status (alarms) Identify failing devices and the reason to fail Perform remote maintenance routines Battery tests Systems parameters Alarms thresholds settings Diagnose/reset of key system components Store tons of data about the network Temperatures, voltages, currents, gen-set fuel consumption, working hours, etc Alarms and events 35

Remote monitoring Web Browser ENEC HTTP, SNMP TCP/IP PSTN GSM EEM protocol RS485 Site ACU SM-BAT SM-IO SM-AC 36

ENEC Enterprise: Site visualization 37

17:37:35 18:52:01 13:05:37 16:45:19 16:53:44 17:02:19 17:10:54 17:19:29 17:28:04 17:36:38 17:45:11 17:53:45 18:02:19 18:10:36 18:19:10 18:27:44 18:36:19 18:43:58 18:52:46 19:01:23 19:09:45 21:58:55 23:37:12 23:45:44 Remote Battery Management Remote battery test Rectifiers are in stand by Battery discharged using the load Discharge sequence monitored in real time and analyzed Battery predictions provide Back up time on each location Remaining life (corrected for temperature & cycling variations) Battery String 1 300-56 200-54 -52 100-50 0-48 Current Voltage -100-46 -44-200 -42-300 -40 Time Gives a good indication of battery status with up to 70% cost reduction Early detection of bad batteries extend operative battery life 38

REMOTE BATTERY TEST -savings Cost saving based on: working hours traveling cost reduction cars investment energy consumption Cost saving example (working hours only) 2 Tehnicians, 8 hours for battery string Working and traveling hours total =20h 1hour cost =20$ 1 battery string = 20h x 20$ or 400$ (labour cost only) 2000 sites x 2 battery strings =4.000x400 or 1,6 mil$ cars, fuel, equipment, energy consumption are extra cost 39

Thank You!