MV Series. Smith Meter Turbine Meters. Features. Operating Specifications SPECIFICATIONS. Bulletin SS02016 Issue/Rev. 2.0 (2/18)

Similar documents
MV Series. We put you first. And keep you ahead. SMITH METER TURBINE METERS FEATURES OPERATING SPECIFICATIONS. Bulletin SS02016 Issue/Rev. 1.

Genesis Series 2" and 3" Steel Meters

Flow Conditioners. We put you first. And keep you ahead. FEATURES OPTIONS. Bulletin SS02007 Issue/Rev. 0.9 (10/14)

6" Steel Model G6. Smith Meter Rotary Vane PD Meters. Features. Operating Specifications Maximum Flow Rate. Options

3" Steel Model E3. We put you first. And keep you ahead.

Smith Meter PD Meters 3" Steel Model E3

Counters, Printers, Preset Counters

Meter, PD Series, K12-S1, S3, S5, S6 and S7

HTM Series Helical Turbine Meters

Densitometers L-Dens 427F Ex Density Sensor Specifications

Smith Meter AccuLoad IV-QT Hardware Worksheet

Model G6-S3. Repeatability ±0.02%

Smith Meter PD Meter Meter, PD Series, K12- S1, S3, S5, S6, and S7

Transmitter, Model UPT

Smith Meter PD Meters Meter, PD Series, M16-S3, S5, S6 (1993-Present) Parts List

BARTON 7400 Precision Gas Turbine Flow Meters

OrificeMaster Specifications

Flow Research and Test Center

Micro Valve. Quick, Sure Response with Design Adaptability. Features and Benefits. Applications. Dependable Performance SPECIFICATIONS / PARTS LIST

High Performance Turbine Technology

Model DE-3 Air Release Heads Parts List

Sentinel LCT. Panametrics Ultrasonic Flowmeter for Liquid Custody Transfer Measurement. GE Sensing & Inspection Technologies. Benefits.

Technical Data. BiRotor Plus Positive Displacement Meter

BARTON 7000 Series Liquid Turbine Meters

Flow Research and Test Center. Creating resource technology for today and tomorrow.

Smith Meter TM Turbine Meters Models 3" Through 16" MV Series Service

DFX Series Liquid Ultrasonic Flow Meters

Smith Meter Truck Meter Packages Specifications

SPARE PARTS & TOOLS SAVE TIME AND MONEY WITH FAURE HERMAN SPARE PARTS AND TOOLS

FH8500. Metering Solution for Custody Transfer Applications. One Step Ahead in Ultrasonic Flowmetering. Main Applications

Fisher D4 Control Valve Assembly

Gas Turbine Flowmeters Robust performance and maximized availability across a range of applications

Electronic Preset Delivery System Smith Meter AccuLoad III. Vapor Recovery. Vapor Recovery System. Overview

Sentinel LCT. Panametrics Ultrasonic Flowmeter for Liquid Custody Transfer Measurement. GE Measurement & Control. Benefits.

Smith Meter Rotary Vane PD Meters Single and Double Case PD Meters Installation / Operation / Maintenance Manual

Tools, Mechanical. All or Multiple Products. Parts List. Feeler Gauges. Spiders and Bushings. Feeler Gauge Extension Rod. Cam Setting Bushing

PRECISION METERS. Tel: / Int'l: Fax: / Int'l: Springer Pumps, LLC Telford, PA 18969

QUALITY INDUSTRIAL FLOWMETERS

Daniel Liquid Turbine Flow Meter Technical Guide

2SGT. Electronic Pressure Instrument. Three Separate Functions in a Single Loop-Powered Device

Non Ferrous Aircraft Fueling Meters

Smith Meter TM Turbine Meters Models 4" Through 24" Sentry TM Series. Service. Contents

DFX series. High-end Ultrasonic Flow Meters for Liquid Hydrocarbons Custody Transfer. 32 beams for ultimate performance

FUNDAMENTALS OF VOLUME MEASUREMENT (TURBINE METERS) Tony Petitto. FMC Technologies Measurement Solutions, Inc.

Liquid Turbine Flowmeters

Product Data Sheet. Turbine Flow Meter. QuikSert DESCRIPTION INSTALLATION FEATURES REPAIR KITS

Transmitter, Model UPT

SITRANS F flowmeters SITRANS F US. SITRANS FUT1010 Ultrasonic flowmeter. Overview. Application

7000 Series Liquid Turbine Meters

Flowmeters. The Satam flowmeter range is used for the custody transfer measurement of liquid hydrocarbons, liquid gas and liquid chemicals.

Mid-West Instrument. Piston Type Model 220. Hazardous Locations. Indicating / Non-Indicating Differential Pressure Switch or Transmitter

PRIME 4 Service. Smith Meter Rotary Vane Meters. Contents

Mid-West Instrument. Diaphragm Type Model 240. Hazardous Locations. Indicating / Non-Indicating Differential Pressure Switch or Transmitter

MS 2500 FLANGED SENSOR WITH A WIDE RANGE OF FLANGE SIZES. Warranty conditions are available on this website: only in English version

Liquid Turbine Flowmeters

ATEX/IECEx Coil Manual Type 200 and 300 Series Coils for EH70 Series Solenoid Valves Issue , Released December 13, 2017

Magnetic-inductive flow meter for hazardous areas

OPTIGAS 4010C Technical Datasheet

Ex m Solenoid Operator Type 0519

Liquid Controls. Turbine Meters for Custody Transfer Flow Measurement of Petroleum Products. Loading Terminal, Offshore, and Pipeline Applications

JUMO dtrans p20. Process pressure transmitter. Type Brief description. Key features. Block diagram

Liquid Turbine Flowmeters

Sanitary Pumps Type F 560 S Version with bearing flange

PRECISION METERS & ACCESSORIES

OPTIGAS 4010C Technical Datasheet

INTERNATIONAL METAL ENGINEERING

PPT 802, Proximity Probe Transducer System

DMP 333. Industrial Pressure Transmitter For High Pressure. Stainless Steel Sensor

RMG Meßtechnik GmbH. Publication No E

Ø 68 mm to ø 115 mm. Material: Weight: Bearing Life: Shaft Loads: Operating Temp.: Storage Temp.: Shock: Vibration: Bump: Humidity: Enclosure Rating:

Intrinsically safe presure transmitters for hazardous environments Type MBS 4201, MBS 4251, MBS 4701 and MBS Technical brochure

Additive Injectors. AccuPlus. Maintenance. The Most Trusted Name In Measurement

SATRON VT Pressure Transmitter

DMK 331P. Industrial Pressure Transmitter. Pressure Ports With Flush Welded Stainless Steel Diaphragm

OM004, OM006 & OM008 Oval Gear Meter

Rosemount DP Flowmeters and Primary Elements

PISTON STYLE GAUGE. Mid-West Instrument

OPTIMASS 2000 Technical Datasheet

Form No. P Meter, PD Model SD, ASD, SF, or ASF-4, 4R, 4V, or 4RV-NF Parts List

Proportional pressure reducing valves type DHRZO and DHRZA standard and ex-proof version, direct operated, ISO 4401 size 06

ABB MEASUREMENT & ANALYTICS DATA SHEET. TEIP11 I/P signal converter for standard signals

JUMO dtrans p20 DELTA

PETROL. Double Case PD Flowmeters. Trust in us Our Quality Counts. Technical Bulletin. PETROL Instruments S.r.l.

Fisher D4 Control Valve Assembly

Ø 68 mm to ø 115 mm. Material: Weight: Shaft Loads: Enclosure Rating: Connection Options. Cable: Cable Glands:

Flow Measurement SITRANS F M. Flow sensor MAG /85. Overview

Micro Motion 7827 Digital Viscosity Meter

Rosemount 3051T In-Line Pressure Transmitter

Type E-10, E-11 Hazardous Area Explosion-proof Transmitters

DFX-MM series. High-end Ultrasonic Flow Meter for Liquid Hydrocarbons Custody Transfer. 32 beams for ultimate performance. L002G DFX-MM leaflet

Model TUR-200D Turbine Flowmeter

Turbine flowmeters Series TM

HELIFLU TM TZN. User s Manual

Liquid Turbine Flow Meter OwnerÊs Manual

Pressure transmitters for heavy duty applications MBS 8200 and MBS 8250

VersaFlow Vortex 100 Vortex Flow Meter Specifications

HELIFLU TM TZN. User s Manual

Liquid Turbine Flowmeter

Ex-proof proportional relief valves Direct or pilot operated, without transducer - ATEX, IECEx, EAC or CULUS

Technical Data B20x. 8 BiRotor, APL. Model B201 [8 ] Model B203 [8 ] Model B204 [8 ] Model B205 [8 ]

Transcription:

SPECIFICATIONS MV Series Bulletin SS02016 Issue/Rev. 2.0 (2/18) Smith Meter Turbine Meters The Smith Meter MV Series Turbine Meter is intended for the measurement of crude oils and other products having a relatively wide range of viscosities. It provides highly accurate measurement for custody transfer and volume balance pipeline applications. The design of the helical rotor makes the MV Series a valuable asset for any pipeline application. Features Titanium swept-front helical rotor swept front design allows for increased meter factor stability while minimizing the effects of containments or debris. Stainless steel interchangeable measuring element provides for ease of serviceability while providing corrosion-free service. Tungsten carbide bearings provide long service life and dependability on a wide variety of products. NACE Compliance to MR0175/ISO 15126-1. Operating Specifications The Smith Meter MV Series Turbine Meter is a Reynolds Number dependent measurement device which accurately measures over a wide measurement turndown range. The Measurement Turndown Range (MTR) of all turbine meters is dependent upon both the Flow Range and the Viscosity Range for a given application. The ratio of Flow Range to Viscosity Range is expressed in Reynolds Number. The MTR is then determined by using the ratio of the maximum Reynolds (Re max) number over the minimum Reynolds (Re min) number. Reynolds number is calculated using the following equations: Re max = Re min = 2214 x Flow Rate max Meter Size x Visc min 2214 x Flow Rate min Meter Size x Visc max The minimum Reynolds number will determine the measurement turndown over which the meter can accurately measure. K-Factor Estimated Minimum Reynolds Number by Product Heavy Crude Medium Crude Light Crude Refined Products Heating Diesel Oil Gasoline LPG 20,000 50,000 1,000,000 Reynolds Number (Re No.)

Linearity ±0.15% over the APPROVED 1 Measurement Turndown Range. Repeatability Per API MPMS or OIML R-117-1. Standard MVTM Operating Range Maximum linear measurement turndown range for a standard 8" MVTM: Measurement Turndown K-Factor (Pulses/Barrel) K-Factor (Pulses/Barrel) Typical 42.8Accuracy Curve for 8" MVTM Accuracy 42.7 over the complete Reynolds number range tested on 1342.6 cst product: 42.5 43.0 10000 100000 1000000 Reynolds Number (Re) 42.8 42.7 Accuracy over the entire flow range tested on 13 cst product: K-Factor (Pulses/barrel) K-Factor (Pulses/barrel) 25.0 20.0 15.0 10.0 5.0 0.0 1,000 10,000 100,000 1,000,000 Reynolds Number 43.0 42.6 42.5 43.0 42.8 42.7 42.6 42.5 43.0 42.8 10000 100000 1000000 Reynolds Number (Re) 0 2000 4000 6000 8000 Flow Range (BPH) 42.7 1 Contact TechnipFMC for review of all applications to determine 42.6 the Measurement Turndown Range for the specific application. 42.5 0 2000 4000 6000 8000 Flow Range (BPH) MVTM Flow Range Minimum and maximum design flow range: Meter Sizes 3" 4" 6" 8" 10" 12" 16" Units Flow Range Normal Flow Range Min. Rate Max. Rate Nominal K-Factor BPH 90 900 600 m 3 /h 14 140 3,775 BPH 190 1,900 250 m 3 /h 30 300 1,570 BPH 400 4,000 100 m 3 /h 64 640 630 BPH 750 7,500 40 m 3 /h 119 1,190 250 BPH 1,250 12,500 18.5 m 3 /h 199 1,990 116 BPH 1,900 19,000 11.1 m 3 /h 302 3,020 70 BPH 2,700 27,000 6 m 3 /h 429 4,290 38 Material Specifications End Connections* Class 150, 300, 600 ASME B16.5, 125-250 AARH finish raised face (RF) flanges *Consult factory for higher working pressure or other types of flanges. ASME Maximum Working Pressure - PSI (kpa) Carbon Steel Flanges 150 285 (1,965) 300 740 (5,102) 600 1,480 (10,205) Meter Operating Temperature Range (with low temperature Carbon Steel Flanges) Meter with: UL / CUL ATEX Pickup Coil and Preamp Pickup Coil and Preamp with 24" Standoff -50 F to 158 F -46 C to 70 C -50 F to 225 F -46 C to 107 C -40 F to 158 F -40 C to 70 C -40 F to 225 F -40 C to 107 C Pulse Output See PA-6 Preamplifier specification bulletin SS02012 or UPCC specification bulletin SS02017. 2 Bulletin SS02016 Issue/Rev. 2.0 (2/18)

Approvals Electrical Safety for Hazardous Locations North American (United States and Canada) and countries following the US NEC Code UL/CUL File E23545 Class I, Division I, Groups C & D Class 1, Zone 1, Tamb = -50 to 70 C, IP66 UNL-UL ENCL 4, CNL ENCL 4 International IECEx PTB 08.0040X (meter) Exd IIC T3 - T6 Tamb = -40 C to +70 C, IP66 IECEx PTB 10.0052X (GP Junction Box) Exd IIC T4 - T6 Gb Tamb = -40 C to +70 C, IP66. European Union: ATEX Explosive Atmospheres Directive, ATEX 2014/34/EU PTB 08 ATEX 1034X (meter) Exd IIC T3 - T6 Tamb = -40 C to +70 C, IP66 Pressure Safety Requirements European Union: PED Pressure Equipment Directive, PED 2014/68/EU CRN Canadian Registration Number Consult Factory Electromagnetic Compatibility European Union: EMC Compliance by Council Directive EMC Directive 2014/30/EU EN 61326-1: Electrical equipment for measurement, control and laboratory use. Housing and Flanges Materials of Construction Internals: Measurement Housing Stators Rotor Bearings Low Temperature Carbon Steel 316 Stainless Steel 316 Stainless Steel Titanium Tungsten Carbide Outer Housing PTB 10 ATEX 1039X (GP Junction Box) Exd IIC T4 - T6 Gb Tamb = -40 C to +70 C, IP66 Weights and Measures Bearings Inner Measurement Housing OIML R117 Test Report European Union: MID - Measuring Instrument Directive, MID 2014/32/EU Consult Factory for others Stator Rotor Stator Testing Dynamic Testing Dynamic testing enables a meter's performance to be simulated over a wide flow and viscosity operating range. Each meter will be tested over the entire Reynolds number range of the application by utilizing a multiple product, high accuracy test. Flow Conditioning The MVTM will be tested with a Flow and will conform to API Chapter 5.3. Field Operating Conditions Flow Range Actual: 6,330 to 19,000 bph (1,010 to 3,020 m 3 /h) MV Test System MV System A HF System B Viscosity Range 10 to 1,000 cst Reynolds Number Range 1,170 to 350,550 K-Factor Size (Inches) 12 Test Systems Reynolds Number Flow (bph) Viscosity Reynolds Number min max min max min max A MV 1,900 8,000 18 300 1,170 82,000 B HF 6,330 19,000 10 18 64,880 350,550 Total Range 1,900 19,000 10 300 1,170 350,550 Bulletin SS02016 Issue/Rev. 2.0 (2/18) 3

Installation The meter must be mounted in a horizontal attitude (±5 ) downstream of a strainer with flow conditioning per API Ch. 5.3, followed by the system control valve. Refer to the installation manual for full instructions. Applications Meter Selection Consult Factory. Minimum Back Pressure In order to prevent cavitation, API MPMS. Chapter 5 recommends a minimum back pressure according to the following: BP = (2 x P) + 1.25 Vp Where: BP = Minimum back pressure P = Pressure drop at maximum flow rate Vp = Absolute vapor pressure at operating temperature Example: 6" MV at 4,000 BPH - P = 4 psi. Absolute vapor pressure of crude oil at operating temperature - Vp = 5 psia. Min. BP = (2 x 4) + 1.25 (5) = 14.25 psi Pressure Drop P PSI 10 8 6 4 2 1 0.8 0.6 0.4 0.2 0.1 0.08 0.06 0.04 10 Data based on 1.0 sp. gr., 1.0 mpa s, 1.0 cp, 1.0 cst 100 Flow Rate (Cubic Meters Per Hour) 50 100 500 1,000 5,000 10,000 3 4 6 8 10 12 16 60 40 500 1,000 5,000 10,000 50,000 100,000 Flow Rate (Barrels Per Hour) 20 10 8 6 4 P kpa 2 1 0.8 0.6 0.4 Pressure Drop Correction For liquids with other than 1.0 cp viscosity and/or 1.0 specific gravity, the meter pressure drop can be estimated by the following equation: P = PD X µ 1/4 X (sp. gr.) 3/4 Where: PD = Pressure drop from chart at desired flow rate. µ = Absolute viscosity (cp or mpa s) sp. gr. = Specific Gravity Example: 6" meter at 4,000 BPH, 50 cp, 0.9 sp. gr. P = 4 psi (from chart) (50) 1/4 X (0.9) 3/4 P = 9.8 psi. Pickup Coil Specifications Type: Inductive V o L e R e Electrical Characteristics Effective Series Resistance (R e ): 4,700 Ω (±10%). Effective Series Inductance (L e ): 6H @ 100 Hz. Minimum Open Circuit Voltage (V o ): 75 millivolts p/p at minimum flow rate. Maximum Transmission Distance: 2,000 ft (610 m) using #20 AWG two-conductor, shielded cable. Note: A preamplifier is recommended for remote instrumentation that does not have Common Mode Noise Rejection. See Bulletin SS02012 for PA-6 Preamplifier Specifications. 4 Bulletin SS02016 Issue/Rev. 2.0 (2/18)

Catalog Code The following guide defines the correct MV Series turbine meter for a given application and the respective catalog code. This code is part of the ordering information and should be included on the purchase order. 1 2 3 4 5 6 7 8 9 10 11 K 2 V F A L U 1 A 0 0 Position 1: Code K - Catalog Code Position 2: Product Line 2 - Turbine Meter Position 3 and 4: Model 2 VE - 3-Inch VF - 4-Inch VG - 6-Inch VH - 8-Inch VJ - 10-Inch VK - 12-Inch VM - 16-Inch Position 5: Pressure Class ASME End Connections (ASME B16.5) A - Class 150 B - Class 300 D - Class 600 Position 6: Material / End Connections L - Low Temperature Carbon Steel RF Flanges Position 7: Internal Configuration U - Swept-Front Titanium Rotor, Unidirectional Flow Position 8: Pickup Coils and Preamplifiers Meter Mounted Junction Box(es) with 1-1 Pickup Coil and Preamplifier 3-2 Pickup Coils and 2 Preamplifiers Pickup Coil(s) with Online Diagnostics S - 1 Pickup Coil and AccuLERT 3 XU T - 2 Pickup Coils and AccuLERT 3 XU U - UPC Compensator with 1 Pickup Coil W - UPC Compensator with 2 Pickup Coils Extended Temperature Range with Preamplifier D - 1 Pickup Coil and 1 Preamplifier on 24-Inch J - 2 Pickup Coils and 2 Preamplifiers on 24-Inch Extended Temperature Range with Online Diagnostics E - 1 Pickup Coil and AccuLERT 3 XU on 24-Inch K - 2 Pickup Coils and AccuLERT 3 XU on 24-Inch Position 9: Testing / Linearity Standard Meters 0 - Linearity ±0.15, Tested with High Performance Flow 1 - Linearity ±0.15, Tested with Conventional Flow Note: All meters are tuned to a specific application. Consult factory for more information. Meters Tuned for Special Conditions A - Linearity (Specify) Tested with High Performance Flow B - Linearity (Specify) Tested with Conventional Flow Meters Configured for Viscosity Compensation with UPCC C - Linearity (Specify) Tested with High Performance Flow D - Linearity (Specify) Tested with Conventional Flow Position 10: Compliance with Standards 0 - UL/CUL Listed, File (E23545) 3 - ATEX / IEC Ex Certified 4 - ATEX / IEC Ex / PED 4 Certified 5 - UL / CUL / CRN Approved Position 11: Specials 0 - None X - Special - Specify 2 Two (2) pickup bosses are standard for all sizes. Additional pickup coils and preamps, can be added if required. 3 The AccuLERT also provides dual channel preamplification and online diagnostics - for details see SS02015. 4 PED required for all European countries; equipment must be manufactured by Ellerbek, Germany facility. Bulletin SS02016 Issue/Rev. 2.0 (2/18) 5

Dimensions Weight Inches (mm) and Pounds (kg) A A 2 3" Explosion-Proof Box (76) 2" (51) 1" NPT B C Second pickup coil spaced 90 electrical degrees, +/- 60 degrees from first coil (optional) Class 150 ASME Class 300 ASME Class 600 ASME Size A B 5 C Wt. C Wt. C Wt. 3" 4" 6" 8" 10" 12" 16" 10.0 (254) 12.0 (305) 14.0 (356) 16.0 (406) 20.0 (508) 24.0 (610) 32.0 (813) 6.38 (162) 6.8 (173) 7.9 (201) 8.9 (226) 9.9 (252) 11.0 (279) 12.6 (320) 7.5 (191) 9.0 (229) 11.0 (279) 13.5 (343) 16.0 (406) 19.0 (483) 23.5 (597) Dimensions inches to the nearest tenth (millimeters to the nearest whole mm), each independently dimensioned from respective engineering drawings. Note Meter weights by flange class with one pickup coil and explosion-proof box. Add 5 lb (2.3 kg) for each additional pickup coil and explosion-proof box. 60 (27) 65 (30) 100 (45) 155 (70) 265 (120) 385 (175) 835 (379) 8.3 (211) 10.0 (254) 12.5 (318) 15.0 (381) 17.5 (445) 20.5 (521) 25.5 (648) 76 (34) 85 (39) 145 (66) 230 (104) 350 (159) 575 (261) 1,080 (490) 8.3 (211) 10.8 (274) 14.0 (356) 16.5 (419) 20.0 (508) 22.0 (559) C/F 100 (45) 110 (50) 245 (111) 320 (145) 560 (254) 750 (340) C/F 5 Add 24" for a standoff when using a preamplifier for temperatures 158 F to 225 F (70 C to 107 C). Revisions included in SS02016 Issue/Rev. 2.0 (2/18): Page 3: Approvals section updated. The specifications contained herein are subject to change without notice and any user of said specifications should verify from the manufacturer that the specifications are currently in effect. Otherwise, the manufacturer assumes no responsibility for the use of specifications which may have been changed and are no longer in effect. Contact information is subject to change. For the most current contact information, visit our website at www.fmctechnologies.com/measurementsolutions and click on the Contact Us link in the left-hand column. TechnipFMC.com TechnipFMC 2018 All rights reserved. SS02016 Issue/Rev. 2.0 (2/18) TechnipFMC FMC Technologies Measurement Solutions, Inc. 500 North Sam Houston Parkway West, Suite 100 Houston, Texas 77067 USA P:+1 281.260.2190 USA Operation 1602 Wagner Avenue Erie, Pennsylvania 16510 USA P:+1 814.898.5000 Germany Operation Smith Meter GmbH Regentstrasse 1 25474 Ellerbek, Germany P:+49 4101 304.0 6