Power pack type UHMZ 25

Similar documents
Power pack type UHMZ 63

Power pack type UHPT

Power pack type UHJV 63

Power pack type UHJV 250

Pressure relief valve, pilot operated, sandwich plate type UZPR10

6-way section directional valves type 6URRE6

Power pack type UHKZ

6-way section directional valves type 6URRE6 consist

Directional control valves hydraulically operated type WHG6/WHP6

3-way flow control valve type UDUE10 is intended for

Pilot operated pressure relief valve type DB 3

Direct operated pressure relief valve type DBD

Directional spool valve type WH16 hydraulically operated

X 7 WK Electrically operated directional spool valve with a soft-shift function type WE6P NUAL NS6. up to 35 MPa up to 80 dm APPLICATION

Double throttle/check valve type Z2FS16

Double throttle/check valve type Z2FS10

2/2 - way cartridge valve type URZS/S

Directional spool valve type WMM 16 hand lever operated

2/2- way directional valve type URZS40 Cover of directional valve type ULZS40

Double throttle/check valve type Z2FS6

PILOT OPERATED PRESSURE REDUCING VALVE TYPE DR

WK Proportional pressure reducing valve, cartridge design type WZRS6. NS 6 up to 5 MPa up to 40. dm /min APPLICATION DESCRIPTION OF OPERATION

DESCRIPTION OF OPERATION

PILOT OPERATED PRESSURE RELIEF VALVE TYPE DB/DBW

Electrically controlled directional control poppet valve type UREZ6

CX3 SOLENOID OPERATING PROPORTIONAL CONTROL BANKABLE VALVES FEATURES ORDERING CODE HYDRAULIC SYMBOLS

Directional cartridge valve type. tight on both sides type 2URED6

Directional cartridge valve tight on both sides type 2URED6 3

NDR Series Rotor Pack

Pilot operated pressure relief valve

Electric Proportional Pressure Reducing Valves Series ERP 03.ERP

2-WAY FLOW CONTROL VALVE TYPE UDRD6

Proportional pressure reducing valve type 3WZCDE6 is a

4/3-way high response directional control valve pilot operated with electrical feedback and integrated electronics (OBE)

PRODUCT CATALOGUE oil hydraulic components and systems

3-way Proportional pressure reducing valve, pilot operated

ZE3 & ZE4 Electric 1 & 1 1/2 HP Pump Series

Pump Safety Block Model DBA... / DBAW, Series 1X

Pilot Operated Pressure Relief Valve Series R5V (Denison)

Meter-in pressure compensator, direct operated

EManually Operated Directional Valves

RA / Accumulator unloading valve, pilot operated, Model DA 6 V.., series 4X. Ordering details DA 6 V 4X. Preferred models 1/8.

Open center control block in mono block design MO-16, 22, 32

Manapak Sandwich Valves. General Description

Proportional pressure reducing valve, in 3-way version

USA Headquarters. Dynex/Rivett Inc. 770 Capitol Drive Pewaukee, WI U.S.A. Tel: FAX:

EManually Operated Directional Valves

Directional Control Valves

p max (see table of performances) Q max (see table of performances) MD1K MD1KD bar

Proportional pressure reducing valve, 3-way variant, pilot operated

LUDV control block of sandwich plate design

Pressure relief valve, pilot-operated. Type DB and DBW. Features. Contents. RE Edition: Replaces:

Double throttle check valve Type Z2FS 10

Solenoid directional valves type DPHI, DPHE, DPHER two stage, ISO 4401 size 10, 16, 25 and 32

WK /2 WAY CARTRIDGE VALVE TYPE URZS 16 COVER FOR CARTRIDGE VALVE TYPE ULZS 16. size 16 up to 42 MPa 140 dm 3 /min DESCRIPTION OF OPERATION

Clamping and drive module

Directional Control Valves Series D81V. General Description. Operation. Features. Specifications

Direct Operated Proportional DC Valves

Pressure reducing valve, direct operated, with pressure monitoring

Directional Control Valves. General Description. Operation. Features

Double throttle/check valve Type Z2FS B/ (New Series) Huade América 1

Monobloc and Sectional Directional Control Valves

AXIAL PISTON MOTORS SHMF

Monobloc and Sectional Directional Control Valves

MONO-BLOCK DIRECTIONAL VALVE HDM 18 SERIES

Sandwich plates Porting patterns to DIN Form A and ISO 4401

Rexroth Hydraulics. Servo directional valve of 4-way design Type 4WS.2EM RE /03.99

Monobloc and Sectional Directional Control Valves

Functional Description HA /2008. Hydraulic Power Units SMA 05. Replaces HA /2007. p max up to 250 bar Q max up to 17 L/min

Pressure reducing valve, pilot operated Type DR

S.A. 193 Stefan Cel Mare str., 2400 Sibiu -Romania

Series Shockless Type Solenoid Controlled Pilot Operated Directional Valves

Control module. Table of contents. RE 51156/05.13 Replaces: Type IH15B

APV Load Sensing Valve

«Standard» Hydraulic power unit BM

Pressure relief valve, direct operated. Type ZDBY D, Z2DBY D. Features. Contents. RE Edition: Replaces: 01.09

Pressure sequence valve, direct operated

Proportional Directional Valve System

Pump safety block. Type DBA; DBAW. Features. Contents. RE Version: Replaces: 10.05

SDH Series. Monoblock and Sectional directional valves

Proportional pressure reducing valve of 3-way design Types 3DREP and 3DREPE

Directional Control Valves. Features. Application. Operation

Flow control valve. Rectifier plate. Type 2FRM5,10,16. Type Z4S5, 10, 16 01/ Sizes 5, 10 and 16 Up to 315 bar Up to 160 L/min

Twin throttle check valve

250 bar P max. Technical Features. Functional Description

Hydraulic pilot control unit of sandwich plate design for the remote control of directional valves, pumps, motors

NG6. Proportional adjustment. Manifold mounting acc. to ISO External drain. Main stage spool type valve. Pilot stage seated type valve.

MDT. Monoblock directional control valves MDT - Directional control valve

Pressure Control Valves. General Description. Specifications. Ordering Information

Directional Control Valves. General Description. Operation. Features

Single-circuit power brake valve LT 05

Ports. Dr. Breit GmbH Carl-Zeiss-Straße 25 D Heiligenhaus phone-contact:

3.3 VARIABLE DISPLACEMENT MECHANICAL COMPENSATION

USA Headquarters. Dynex/Rivett Inc. 770 Capitol Drive Pewaukee, WI U.S.A. Tel: FAX:

Winch control block. RE 65051/08.04 Replaces: Type YM-WCB

Directional Control Valves. General Description. Operation. Features

Pressure sequence valve, direct operated

RC /

Fixed Displacement Plug-In Motor A2FE

DFE10. solenoid control monoblock valve. Ordering codes. Description example : Diverter valve DFE10/3 A 18 ES - W VDC - SAE - <CVN>

Transcription:

ower pack type UHMZ 25 p max = 20 Ma Q = 10 max cm 3/rev WK 560 503 04.2008 LICION ower pack is intended to supply hydraulic system with hydraulic fluid (oil) according to the required parameters (pressure and displacement). DESCRIION ower pack in standard consists of the oil tank and the key accessories such as: drain breather filter used also as the oil filler oil level indicator (optical) oil drain plug magnetic plug and of pumping unit (electric motor - gear pump), oil filter (low pressure filter), and also measuring block with pressure gauge switch, pressure gauge and output connections. Standard version of the power pack can be extended (upon customer request) with: hydraulic control system according to individual scheme; other equipment and hydraulic machines, which are not included in the data card, after prior consultation with the manufacturer electric control system he extension of hydraulic system can be made: on the blocks for column mounting (WK560 520) standard version on multi-station manifold blocks type ULR 6 6 (WK 450 499) ower pack is usually used for short - time operation. When the power pack is applied to continuous running under load, outside cooling system must be used. ECHNICL D (table1) Nominal oil tank capacity 25 dm 3 Oil capacity difference corresponding to oil level up to 5,6 dm 3 difference max - min Hydraulic fluid mineral oil Operating temperature range - 10 up to + 70 C Standard filtration 16 µm Viscosity 10 380 mm 2 /s Motor supply voltage 230/400V 50Hz (other, if agreed) ype of pump 10C2,5X053G 10C4,2X053G 10C6,1X053G 20C10X016G Operating pressure up to 20 Ma up to 20 Ma up to 20 Ma up to 20 Ma Displacement 2,5 cm 3 /revolution 4,2 cm 3 /revolution 6,1 cm 3 /revolution 10 cm 3 /revolution ype UHMZ 25-1 -

HYDRULIC SCHEME Connect nections (table 2) ort Connections for NS6 G1/2" G1/2" G1/2" G1/2" outputs of receivers R1 R2 R3 R4 R5 R6 hydraulic equipment Y M Operat ating pressure range r depend nding ng on the motor m or power p and type of f pump (table 3) Motor type ower [kw] 10C2,5X053G pressure [Ma] 10C4,2X053G pressure [Ma] 10C6,1X053G pressure [Ma] 20C10X016G pressure [Ma] SKg 80-4 0,55 7 - - - SKg 80-4 0,75 9 6,3 - - SKg 90- S4 1,1 13,5 10 6,3 - SKg 90 L4 1,5 19 13 8,4 5 SKg 90 L4C 2,2-20 12,3 7,6-2 - ype UHMZ 25

OVERLL ND CONNECION DIMENSIONS 20 190 312 (6 x 52 mm) 887 270 325 40 25 45 365 415 O11 310 400 45 388 Over verall l dime d imensions s depending ng on the motor m or power p and type of f pump (table 4) Motor type Dimension 10C2,5X053G 10C4,2X053G 10C6,1X053G 20C10X016G SKg 80-4 0,55 [kw] 570 - - - SKg 80-4 0,75 [kw] 587 587 - - SKg 90-S4 1,1 [kw] 611 611 611 - SKg 90L4 1,5 [kw] 636 636 636 636 SKg 90 L4C 2,2 [kw] - 655 655 655 ype UHMZ 25-3 -

DDIIONL When selecting power pack to the machine it is necessary to consider its total heat balance by specifying oil temperature in the tank it should not exceed 55 C (328 K). If necessary, oil cooler must be used for the hydraulic system. hermal power output of the power pack tank to the environment can be estimated using below formula or diagram. N output = k x x N output [ W ] - thermal power output of the tank [m 2 ] - active surface area of the tank for the power pack tank UHMZ 25 = 0,75 m 2 k [W/m 2 x K] - heat exchange factor k = 5 W/m 2 x K - when poor air circulation, unfavourable location, k = 10 W/m 2 x K - normal air circulation from all directions, k = 20 W/m 2 x K - when intensive air circulation (unnaturally forced), [ K ] - temperature difference between the tank (oil) and the environment [K] 50 40 30 20-3 2 k = 5 x 10 [kw/m K] -3-3 -3-3 2 k = 10 x 10 [kw/m K] -3 2 k = 20 x 10 [kw/m K] 10 0 0,1 0,2 0,3 0,4 0,5 0,6 0,7 0,8 N output [ kw ] hermal power output of the power pack tank UHMZ 25 ype UHMZ 25-4 -

HOW O ORDER ny order should be addressed to the manufacturer according to the below coding. UHMZ 25 ank capacity 25 dm 3 = 25 * ype of pump 10C2,5X053G = 2,5 10C4,2X053G = 4,2 10C6,1X053G = 6,1 20C10X016G = 10 Motor power (according to the table 3) 0,55 kw = 0,55 0,75 kw = 0,75 1,1 kw = 1,1 1,5 kw = 1,5 2,2 kw = 2,2 Nominal size of hydraulic elements mounted (referred to connections of directional valves) NS6 = 6 Designed version standard version (without connection for directional valve) with the connection for one directional valve with the connection for two directional valves with the connection for three directional valves with the connection for four directional valves with the connection for five directional valves with the connection for six directional valves = no designation = R1 = R2 = R3 = R4 = R5 = R6 Successive number of power pack version (given by the manufacturer of the power pack when order confirmed) = XXXX Further requirements in clear text (to be agreed with the manufacturer) Coding example: UHMZ 25-4-0,75-6-R3-XXXX NOE: ype, quantity and placing hydraulic equipment (directional valves, valves and other), must be specified in the hydraulic scheme or in another clear way. ype UHMZ 25-5 -

elow hydraulic equipment manufactured by ONR-WDOWICE S.. that can be used for control systems (table 5) Directional spool valve, electrically operated WE 6 according to WK 499 502 Directional spool valve, hydraulically operated WH 6 according to WK 420 170 Directional spool valve, hand lever operated WMM 6 according to WK 420 170 Directional spool valve, rotary knob operated WMD 6 according to WK 420 170 ressure reducing valves, sandwich plate UZRC 6 according to WK 493 061 ressure sequence valves, sandwich plate UZKC 6 according to WK 393 060 Check valves, sandwich plate WZZC 6 according to WK 450 355 Double check valves, pilot operated Z2S 6 according to WK 450 360 Double check valves, sandwich plate Z2FS 6 according to WK 450 232 ressure switches (with subplate UŁC 6) USH 4 according to WK 450 398 ressure relief valves UZR 6 according to WK 494 060 ONR Silesia S.. ul. Wojska olskiego 29 34-100 Wadowice tel. +48 33 823 44 41-45 fax.+48 33 823 39 36 www.ponar-silesia.pl - 6 - ype UHMZ 25