Self-Bunded Fuel Storage Tanks. for hydrocarbon liquid fuels

Similar documents
FuelEquipment.com FUELLING

FuelEquipment.com FUELLING. Self-Bunded Diesel Fuel Trailers. Custom fuelling solutions. Australian designed & manufactured.

FuelEquipment.com FUELLING. Fuel Tankers. Custom fuelling solutions. Australian. Systems & Equipment

Conventional single skinned diesel fuel trailers

FuelEquipment.com FUELLING

Self Bunded Storage & Dispensing Solutions for Petroleum Products

Self Bunded Tank Tainers

DTE PACIFIC CAPABILITY STATEMENT

Bulk Fuel and Lubricants Storage Total Fuel and Lubricants Management Solutions

PRODUCT CATALOGUE MANUFACTURERS OF READY TO WORK TRUCKS

PRODUCT CATALOGUE MANUFACTURERS OF READY TO WORK TRUCKS AND MODULES

SERVICE MODULES AND WATER TANKS TO SUIT CATERPILLAR RIGID DUMP TRUCKS. Solely-owned subsidiary of Alpha Plant Maintenance

.4 Emergency and normal vents and terminations. .1 CAN/CSA-B139-09, Installation Code for Oil Burning Equipment.

CHOOSE CARBERY FOR. Quality Reliability Safety HAULAGE CONSTRUCTION AGRICULTURE COMMERCIAL

Overview. u Baffled inner tank ensuring excellent stability. u Full height cabinet for access to dispensing equipment

HYDRAULIC QUALITY PRODUCTS

Highway diesel bowsers with adblue storage

Fuel Point and Fuel Station Diesel Storage Solutions. For Farm, Business and Industry. Issue JS/UK/A4FS1007

engineering product catalogue

Spill and splash free; versatile diesel transport tanks

Code Requirements for ASTs at Motor Vehicle-Dispensing Stations

FUEL TANKS FUEL TANKS

Customer Name. Customer Business. Location. Case Study Defence Fuel Cart RAN Mine Hunter Coastal Fleet HMAS Waterhen

Portable Fuel Dispensing Equipment

PETROLEUM S T O R A G E 01

Code Requirements for ASTs at Motor Vehicle-Dispensing Stations

FUEL STORAGE AND RETICULATION SYSTEMS

THE RANGE THE WESTERN RANGE OF BULK STORAGE TANKS FUEL STORAGE & STATION TANKS ENVIROBULKA. W: T: +44 (0)

PEI/RP Recommended Practices for Installation of Bulk Storage Plants

. Los Angeles International Airport Rules and Regulations SECTION 09 FUELING

STEEL DIESEL STORAGE SOLUTIONS STORAGE AND DISPENSING SOLUTIONS CAPACITIES FROM ,000 LITRES

STEEL DIESEL STORAGE SOLUTIONS STORAGE AND DISPENSING SOLUTIONS CAPACITIES FROM ,000 LITRES

STEEL DIESEL STORAGE SOLUTIONS STORAGE AND DISPENSING SOLUTIONS CAPACITIES FROM ,000 LITRES

ADDENDUM #1. A. Alternate Bid Item #3A - The procurement and installation of a new 12,000 gallon UL 2085 rated AGT tank for

Fuel Transfer & Metering

LIQUEFIED PETROLEUM GASES

Learning Legacy Document

Kamal Industries.

Gallagher Vapour Recovery

6FACTS YOU MUST KNOW BEFORE BUYING A PRESSURE WASHER


Fuel and Refuelling ! WARNING: SAFETY PRECAUTIONS FUEL TANK FILLING

World Class Fluid Storage & Handling Solutions

TODO-GAS COUPLINGS TODO-GAS DRY-BREAK COUPLINGS

About Supply Plus Ltd

Technical standards and safety for CNG and LNG

Draft Standards and Best Practice Guidelines for Vapour Recovery at Petrol Service Stations. Environment Protection Authority

TRADE SPECIALS EDITION 2 WORKSHOP EQUIPMENT ON SALE NOW ALL PRICES INCLUDE GST. tecalemit.com.au

Tank Cleaning Screening Questionnaire

Supply+ are the leading supplier of specialist products.

PETROLEUM STORAGE. Used Oil and Fuel Oil Storage Double Wall Above Ground Storage Single Wall Above Ground Storage Mobile Petroleum Service Tanks

TruckMaster PORTABLE DIESEL STORAGE AND DISPENSING SOLUTIONS LEADING CHANGE AVAILABLE FROM LITRES

RSC-G-004-B Guidelines For The Design Of Section 3 3 ELECTRIC TRACTION SYSTEMS 2

THE KEY RELATIONSHIPS BETWEEN FIRE CODES, NEW YORK AST REGULATIONS AND SPCC PLANS

Reviewed: DD Month University Code of Practice for Electrical Safety. PART B - Design and Construction of Electrical Equipment within the University

Earthsafe Systems, Inc. Page 1

1200W INVERTER GENERATOR

MOBILE PRODUCT RECOVERY TANK

Date. Director c/o Petroleum Storage Program Manitoba Conservation and Water Stewardship 1007 Century Street Winnipeg, MB R3H 0W4

Verti Blast. User Manual. Order code: EQLED355

Offshore Fuelling Systems

Gasoline and Safety Cans in Golf Maintenance

THE PETROLEUM REGULATION ACTS (NI) 1929 & 1937

SA300N Air Hose Reel. SAW100 Air Hose Reel SAW200 $77.00 INC

Customer Site Self Assessment Form - other than Jetty. Checklist

TRADE SPECIALS. May - August 2018 MAKING EVERY DROP COUNT NEW 12V/24V REFUELLING PUMP KITS EQUIPMENT A-FLO S A-FLO S UPDATE $427 $437 QUALITY RELEASE

Winning Bid US Petroleum Equipment Walts Petroleum Northwest Petroleum Petro-Chemical Systems Kimberly Green Bay Wausau Fond Du Lac

Below ground stationary container systems for petroleum design and installation

Code Requirements on Aboveground Storage Tanks Dispensing Fuels At Motor Vehicle Fuel-Dispensing Stations

Petroleum Advisory Services, Energy Programme PETROLEUM AND LP GAS CYLINDER STORAGE INSPECTION GUIDELINES

PROCEDURE. Operative Date: 22/12/2016 Department: HSEC. Revision: Author: D Steel CONTENTS

Energy Storage Solutions. TruckMaster LEADING CHANGE PORTABLE DIESEL STORAGE AND DISPENSING SOLUTIONS AVAILABLE FROM LITRES

Code of Practice for Motorsport Fuel - Storage and Handling

Bulk Storage Systems. Clean Organized Safe Efficient Reliable

AIR-COOLED DIESEL GENERATOR OWNERʼS MANUAL. This manual contains important safety information. TDG2500E TDGW7000E TDG7000SE TDG4500E

Earthsafe Systems, Inc. Emergency Power Fuel Systems Recommended System Standard

Variable speed hybrid power system

FUELLING COMPONENTS LIMITED >

TRAILER TANK SIGNAGE REQUIREMENTS. The following information has been received courtesy of David Smith at Allied Petroleum.

Vapour recovery systems for fuel retail outlets

Auto-Blast Complete Containment System

Equipping the Force Fuel and Water Systems

Changes to Chapter , Florida Administrative Code Underground Storage Tank Systems (USTs) Effective 1/11/2017

GUIDELINES FOR SAFE ABOVE GROUND FUEL STORAGE ON FARMS AND INDUSTRIAL SITES

Underground Storage Tank Annual Compliance Inspection (Revised 1/2015)

CURRICULUM BOSCH-REXROTH (CENTRE OF EXCELLENCE) GANPAT UNIVERSITY

SOL UTION O VER VIEW

HYDROGEN REFUELLING STATIONS (HRS): RECENT AND CURRENT PERSPECTIVES

original operating manual Operating manual Translation of the Item-No.: ,

PETRO CUBE Operations Manual

an EnerSys Company Relocatable Mobile Solutions Engineered for all Environments

Fuel Storage. Regulations and Technical Specifications

Spillage from a semi-buried jet fuel tank 30 December, 2005 Sainte-Marie [Reunion Island] France

FUELLING COMPONENTS LIMITED >

Sweden. General Information. Art. nr.: PR Version:

ADDENDUM. Lithium Batteries

2018 CAMS MANUAL OF MOTOR SPORT

Focus on the engineering & permitting requirements for installing a new fuel facility at the Port of Olympia;

MSC Guidelines for Fuel Oil Systems

Fueling Global Aviation since 1972 RELIABILITY SUPPORT DELIVERY TM

Transcription:

Self-Bunded Fuel Storage Tanks for hydrocarbon liquid fuels Fuelling manufactures a wide range of fuel storage and transport tanks. These include self-bunded and conventional tanks for diesel, ULP and aviation fuels, tanks for transporting fuels, including demountables for diesel and tanks suitable for AS2809 compliant Dangerous Goods vehicles. We also specialise in fitting all required dispensing equipment, management systems and a full range of accessories to customise your tank to suit your requirements. All systems are thoroughly wet tested prior to despatch to minimise onsite works and commissioning. designed & manufactured Self-bunded bulk storage tanks for diesel & ULP. Custom tanks for other fluids available. Access ladder & platforms can be installed on either side of tank Fuelling

General Information The following information is provided for general guidance only on topics as shown. No responsibility is accepted for any outcomes or situations arising from your interpretation of any of the guides. In all cases it is recommended that a qualified consultant be engaged to guide your installation of fuel storage and dispensing systems. Compliances Fuel Categories Dispensing fuels Tanks constructed by Fuelling are built to the following Standards AS1692-2006 Steel tanks for flammable and combustible liquids AS 1940-2004 The storage and handling of flammable and combustible liquids AS1657 Fixed platforms, walkways, stairways and ladders - Design construction and installation. We have a rigorous QA testing regime which every tank undergoes prior to delivery. These include pneumatic bubble testing & full hydrotesting, depending on tank type. Aviation fuel tanks Please be aware that tanks shown within this brochure are not designed for use with aviation fuels - please see separate brochure detailing our range. Plug & Play systems Our tanks are generally ready to go when delivered - except for assemly of the ladder/platform which is shipped separately. The ladder can be installed on either side of the tank to suit. We prefer to install any specified dispensing equipment or other accessories so that we can wet test complete operation of the whole system prior to despatch. This means that onsite work is minimised to provision of suitable footings, connection of required power supply and filling for operation. Tank Management Tanks can be fitted with management systems that record all issues from the tank - vehicle id, operator id, volume, time etc. Tanks can be fitted with level monitoring devices accessible by phone, internet or proprietary systems. Retailing fuel from your tank We can supply and fit, calibrate & certify all required dispensing equipment to National Measurement Institute standards for legal reselling of fuels if required. Liquid fuels are categorised according to their flashpoint (see AS1940) Class 3 Flammable Liquids include ULP, Avgas, Jet-A1, Mogas, most Kerosenes and a wide range of other fluids including solvents. These have a lower flashpoint than Diesel, which is classified as a Combustible Fluid C2. Requirements for equipment, location, electrical, site fixtures etc are more stringent for Class 3 Flammable Liquids than for a Combustible Liquid C2. Site & location requirements Site requirements (foundations, footings, location, proximity to major works etc) for fuel tanks are as described within AS1940-2004. Foundations & footings will need to be determined by a properly qualified person with local knowledge of terrain & soil types. It is highly recommended that a properly qualified Dangerous Goods Consultant (member of the Institute of Dangerous Goods Consultants) be engaged to advise on all aspects of Class 3 Flammable Liquids storage and dispensing systems. Transporting your tank We can arrange quotation for delivery of your tank or you can arrange this yourself. Generally, you will also need to organise & co-ordinate a crane to unload & place. Power/flow requirements As a general guide & depending on the tank size accessories included, a 240v ac single phase power supply will enable a delivery flow rate of up to approximately 80-90 lpm. Tanks used in industrial applications where high flows are required (above 100 lpm) usually will require 3 phase 415v supply or a suitably sized engine. 12 & 24v DC pumps are capable of flows up to approximately 50 lpm. Note: all fluid from a compliant self-bunded tank has to be delivered through an antisiphon valve which reduces flows somewhat. Getting the fuel out of your tank into vehicles, machines or other tanks requires much planning and consideration of your requirements. Please see separate section with our options packages. Basic considerations are: Flow rate required Hose length & hose storage method Nozzle type - systems can be fitted with either standard top fill nozzles, Wiggins type quick-fill nozzles or both Pump system Power requirements to achieve flows Flow meter - is the system to be used for reselling? Filtration Management system to track who, when & how much fuel was taken. Tank filling methods In most cases, it is beneficial for you to check with your fuel supplier as to what is their preferred method of filling your tank. This can be a bottom filling system with various connection fittings, top filling - we can ensure that the correct method & fittings are included in your tank. We can supply your tank fitted with automatic shutoff at SFL (overfill protection) that is suitable for remote fill points. Warranty Our tanks have a 20 year warranty for integrity when used in accordance with standard industry practice. All equipment fitted is covered by 12 month warranty for performance as specified and to the limits of the manufacturers warranty. Fuel supply to Gensets Please be aware that all compliant selfbunded tanks have to be fitted with an anti-siphon valve - this means that there is no head and so the generator system must have adequate lift pump or be equipped with day tank and suitable refilling system. Enquiry? - call 1800-025 869 or email sales@fuelequipment.com Fuelling

Self-bunded Tanks Diesel ULP Self-bunded cylindrical tank dimensions Cat# Cat# Type SFL A B C D E F Mass 123033 123098 T12 11630 3830 2412 2980 3710 2100 3125 3850 123039 123101 T22 21780 6430 2412 2980 3710 2100 3125 5750 123035 123102 T35 33440 6780 2862 3430 4170 2350 3510 7220 123036 123103 T50 50200 9830 2862 3430 4170 2350 3510 10120 Fuelling

Self-bunded cylindrical tanks A typical dual outlet dispensing system fitted to a self-bunded tank. Powered by 415v 3 phase supply, this system includes dual nozzles - a standard top fill automatic nozzle for smaller vehicles as well as a Wiggins quick-fill nozzle for rapid refuelling of heavy machinery. All deliveries are controlled and monitored by a Smart- Fill management system which records details of quantity, vehicle/plant id, operator, date & time. This data is easily transferrable to PC to produce spreadsheets. Also fitted is a 600 lpm centrifugal pump for high flow transfer of diesel from delivery tanker into storage. All equipment is safely secured in lockable enclosure. Fuelling

Self-bunded cylindrical tanks A typical 240v single nozzle dispensing system A typical 240v ac dispensing system - ideal for trucks, buses and other standard top-fill vehicles. Fitted with a Fill-Rite FR310 series high flow pump, this system can be fitted with a variety of options. Unit shown is fitted with the SmartFill management system to monitor all deliveries. This system delivers approximately 75-80 lpm - with variation according to the size of the tank, fuel level and the equipment included. Options available include: Various mechanical or electronic flow meters. Goldenrod 10 micron filtration Manual or spring rewind hose reel. Hose length to suit. All equipment is safely secured in lockable enclosure. Shown are various dispensing systems which can be fitted to your tank. These can include DC, 240c ac, 415v 3 phase, diesel & petrol engine-powered pumps and pneumatic systems with single or dual outlets. Pumps can be fitted for resale, with management systems or industrial flow meters. Fuelling

Self-bunded rectangular tanks Fuel return connection point can be fitted for generator fuel supply applications Diesel ULP Self-bunded rectangular tank Cat# Cat# Type SFL A B C D E F Mass 123034 123100 T1.5 1450 2400 1150 700 2480 1770 880 800 123030 123047 T2.5 2580 2410 1120 1210 2490 1730 1390 1070 123032 123074 T5 5230 3200 1120 1810 3280 17630 1990 1675 Notes All dimensions shown are nominal and can vary due to manufacturing and plate dimension variations Safe Fill Level is 97% of gross volume Tanks for ULP supplied with vent risers to 4m from ground level - to be fitted on site We normally supply all self-adhesive signage for Class 3 product tanks to be fitted onsite due to transport regulations. Various dispensing systems for rectangular self-bunded tanks Fuelling

designed & manufactured Self-bunded rectangular tanks A 5000 litre self-bunded tank for ULP. Supplied with piping to connect to bowser at service station site. Fuelling

Self-Bunded Waste oil Tanks 5000 litre self-bunded tank custom made for waste oil collection in a busy workshop. Features collection funnel, overfill warning alarm, interstitial monitoring, spill containment and step for safe access. Other tanks in our range Tanks To AS2809 for DG vehicles Diesel tanks for service trucks Self-bunded aviation fuel tanks Aviation fuel tanks Demountable self-bunded tanks Oil & water tanks for service trucks Aluminium tanks to AS2809 Tanks to AS2809 for trailers Got a question? Need a quote? Fuelling Call 1800-025 869 or email sales@fuelequipment.com