Usage Instructions of Solar Control for 3Way-Ball Valve

Similar documents
USE AND INSTALLATION HANDBOOK

PURE SINE WAVE DC TO AC POWER INVERTER

DC Master 24/ A

Revision THERMO TECHNOLOGIES. USDT 2001 Differential Controller. Installation and User s Guide

Demand Switch NEFA20 Plus. Installation Guide. Please read this entire guide before beginning the installation!

USER S MANUAL. Installation, Operation, & Maintenance

Owner s Manual GLASSLINED PUMP TANK

Solenoid Valve DF-SB-series

OPERATING INSTRUCTIONS

Compact System NRGS 11-2 NRGS Original Installation Instructions English

HST-BL-2830MS & HST-BL-2830MS-USA

SBS Manual for the specialised craftsman. Filling and flushing station. Connection Operation. en Manual

Oil-free piston compressors KK and piston vacuum pumps KV

2-PHASE STEPPING MOTOR DRIVER FE Z5 DISPENSE

Operating instructions Safety sensor BNS About this document. Content. 6 Disassembly and disposal 6.1 Disassembly Disposal...

MANUAL. Single charger

Operations Manual. Zero Speed Switch Sensor Model ZS09P

Softstarter SAS SAS 11PUST, 22PUST Assembly- and Commissioning Instructions

HOME CHARGER MODE 2. Series to /32A single phase CONTENTS. Manual IMPORTANT SAFETY INSTRUCTIONS 3 SAFETY INFORMATION 4 INSTALLATION 5

AXIAL FANS Axis / Tubo OPERATION MANUAL

USER MANUAL GEBRUIKSAANWIJZING GEBRAUCHSANWEISUNG SKYLLA 24/100 3-PHASE CE

RE-PR1-F 1-Phase Din-Rail Mount 1.5, 3 & 6kW

Kompensator External Low Voltage Heating Cable System

MODEL A96 SERIES. 130Vdc Switchmode Utility Rectifier / Battery Charger. Used with LaMarche Power Cage ECN/DATE

Declaration of Conformity

VITA ZYrcomat. Operating manual Date of issue: 01-05

WELDING INVERTER. PEGAS 160 E Smart PEGAS 200 E Smart OPERATING MANUAL. ALFA IN a.s. PEGAS E Smart Manual EN 04

Solenoid Valve DF-SA-series

Owners Manual: - Pumps

Operation & Service Manual

MICROCARE 3 PHASE INVERTER MANUAL

PD404-AN V analog control 4 Channel x 500 W Dimmer & Switch Packs ANALOG 0-10 V. Serial Number

Wilo-Control SC-Fire Jockey

CAUTION CM-SE CM-S21 CM-S41

Mounting and Operating Instructions EB 5868/5869 EN

GRUNDFOS INSTRUCTIONS. Grundfos ALPHA Installation and operating instructions

SMART ENERGY SAVER Manual

Installation Instructions: K-Safe-T-Drift

RE-PR3-E-86&105 3-Phase Panel Mount 86 and 105kW

Central Inverter SUNNY CENTRAL 500CP-JP / 500CP XT / 630CP XT / 720CP XT / 760CP XT / 800CP XT / 850CP XT / 900 CP XT

HANGKAI GROUP HOYMILES MICRO-INVERTER MI-250

EV-2051-M Electric Motor. Operation and Maintenance Manual

UL AND CODE COMPLIANCE

MWR Reamer 08/01/2010

Copyright 2012 DelSolar Co. Ltd MQWRD installation manual-iec Ver. 1.4

Operating Instruction Manual for Energy Management System EBL 99 C, Art.-Nr Seite 1 / 7

20 amps 220 amps, 60 Hz VDC VAC G3PA-420B-VD-2 DC amps 440 amps, 60 Hz G3PA-450B-VD-2 DC12-24

Operation and Maintenance Manual for Multipurpose Actuators. 120 VAC Actuator 12 VDC Actuator 12 VDC Actuator

MICRO-INVERTER OMNIKSOL M-300

StarEye. 350 ma version. No control electronics on board

GEIGER-GJ56.. with mechanical end stop For Venetian blinds and exterior blinds

Applicable output load (See note 2.) Photocoupler Yes Yes 40 A at 110 to 220 VAC 5 to 24 VDC G3NB-240B 5 to 24 VDC G3NB-240B-UTU 5 to 24 VDC

ECONOMISER SERIES E2T USER MANUAL

SOLAR SPOT Installation Guide

QSI (Q-Star) Electronics Owner s Manual

MINICHARGER. User Manual and Safety Instructions. Version 20/12/2016

ULTRASONIC FLOW SENSOR QALCOSONIC FLOW 2

Model Number Structure

Model LA 4400 Time Delay OFF Controller

Before installing this unit, read the operating instructions carefully. Strictly adhere to these operating instructions.

Braking Devices BR 230/ Assembly- and Commissioning Instructions

Installation Manual. Mixing Box Control Systems Installation, Operation, and Maintenance Manual. 605 Shiloh Road Plano, Texas

MODEL A97 SERIES. Switchmode Utility Rectifier/Battery Charger ECN/DATE

Solar Thermal. Grant Solar Pump Station Installation & Servicing Instructions

RS-3 PRO RS-1007 PRO. CAT IV Analog Clamp meter Series. Users Manual. For detailed specifications and ordering info go to

INSTALLATION AND MAINTENANCE MANUAL FORM #PM-126 REV A 12/09

MICRO SWITCH INSTALLATION SHEET

GEIGER-SOLIDline* GEIGER-Touch (GU45..M) for rolling shutters, awnings and screens. Bedienungsanleitung. Operating Instructions. Manuel d utilisation

MV Series Motors Operation & Parts Manual

DeltaSol AX * *

Installation Manual LIGHTWAY PV MODULES. Revision Date March 30, 2013 /Applicable for IEC certified products

Filtered PWM Speed Control for Permanent Magnet DC Motors

A Member of the. Integrated Metering Technologies

99 Washington Street Melrose, MA Fax TestEquipmentDepot.com. Instruction Manual. Model 2831D 4 ½ Digit True RMS Digital Multimeter

A408 GB. Pneumatic oil and diesel pumps 1:1

A Member of the. Integrated Metering Technologies

MODULATING SERVICE ELECTRIC ACTUATORS OPERATION AND MAINTENANCE MANUAL COMMERCIAL AND INDUSTRIAL VALVES AND AUTOMATION

DeltaSol AX. RESOL DeltaSol AX * * Mounting Connection Operation Application examples. manual

B2000 SERIES TACHOMETERS DIGITAL OR ANALOG DISPLAYS

Electromotoric Actuators

GSL Electronics Modified Sine Wave Power Inverters

powerdriveinverters.com Owner s Guide Please Save for Future Reference 300 Watt DC to AC Power Inverter

Rental Industry Safety Tester Safe Check 5s

Solid State Relays G3RV. Model Number Structure. Ordering Information. Model Number Legend. List of Models. SSR and Socket Combinations

Installation and Operating Instructions Magnetic Vibrator MR 1

IS7.6 INSTALLATION MANUAL

Rotary Valve Maxflo + 60 and 80 Opening type NT

powerdriveinverters.com Owner s Guide Please Save for Future Reference 100 Watt DC to AC Power Inverter

Intelligent Battery Charger

GUIDELINES ON ELECTRICAL SAFETY AT WORKPLACES

TURBOTRONIK NT 151/361

GEIGER-GJ5610v1 with mechanical end stop For Venetian blinds and exterior blinds for 100 V power supply

Operation & Service Manual

(with Class-1 AC resistive load) 3. G3PB-215B-2N-VD kW max. (25 A) G3PB-225B-3N-VD 2. G3PB-225B-2N-VD kw max. (35 A) G3PB-235B-3N-VD 2

Operating Instruction Manual of Energy Management System EBL 208, Art.-No Seite 1 / 7

LED FlatPanel Gen. 2. LED FlatPanel Gen. 2 ULTRA FLAT LIGHT PANEL. LED FlatPanel Gen. 2

Electronic Ballast EVG 2000-T

FOR NEW ZEALAND. T-604 WASTE DISPOSER B. HYDRAULIC CHARACTERISTICS &TECHNICAL SPECIFICATIONS. DECLARATION OF COMPLIANCE

TIC 300 PRO. Users Manual Mode d emploi Bedienungshandbuch Manual d uso Manual de uso. Non Contact AC Voltage Detector. High Energy Tic Tracer

Installation and Operation Instructions. VAG ROTOP Portable Electric Drive

Transcription:

Table of Contents: Page: 2 Safety Instructions 3 Intended Use / General / Warranty / Installation: 4 Schematic Diagram: Mounting the sensor 5 Start-UP 6 Note: 7 Electrical connections: Technical Specifications 8 Connection types 9 Parts catalog 10 Dimensions: Failure Cause: In the event of damage arising out of the non-compliance with the present Instructions for Use or if lead- sealed parts have been tampered with, the warranty furnished shall become void. We do not assume any liability for consequential damage. Prior to using the equipment, please read the present Instructions for Use thoroughly. PRECISION RESULTS INNOVATION - PRODUCTION Seite- 1 -

Safety Instructions: This device was built and tested in conformity with the safety provisions for electronic equipment and has left our factory in a flawlessly safe and secure condition. To preserve such condition and ensure a perfectly safe operation, the user shall observe the Safety Instructions and the Instructions of Use. The required fitting work may be carried out only by a duly qualified and licensed fitter or electrician. Caution when working on house roofs. These may only be done when all safety regulations are preserved. Use antifall guard! The required electrical installation work shall be executed in conformity with the respective local and regional standards (e.g. ÖVE, VDE..) and, where applicable, with the relevant regulatory provisions. For the electrical connection, it is necessary to install a disconnector unit in the fixed electrical installation, making it possible to disconnect all poles of the electrical connection, with a contact gap of at least 3 mm from the main supply. Make sure that the supply voltage is fused properly and that a 30mA residual-current Circuit-breaker has been installed. Use the device in dry rooms only where no flammable gasses and vapours may exist. Do not start using the device immediately after it has been brought from a cold into a warm room. Otherwise, the condensation water might destroy it. If the device shows visible damage, no longer functions or has been stored in adverse conditions for an extended period of time, it must be assumed that it is no longer safe to use. In such case, the device must be secured against its unintended activation and, where necessary, be shut down. Prior to opening the body pull the plug. The motor electric is not galvanically separated from the mains. Opening its cover panels or removing components from it may cause energized components to become exposed. Prior to calibrations, maintenance jobs, repairs or the exchange of components or modules, the device must be disconnected from all voltage sources if opening the device is necessary. If, following such opening, a calibration, a maintenance job or a repair on the energized device is unavoidable, this may only be done by a skilled specialist who is aware of the related hazards and the relevant rules and provisions. Capacitors contained in the device may still be charged, even if the device has already been disconnected from all voltage sources. Carry out any assembly and disassembly of the valve only in the depressurized state (drain the pipe line first) Please consider flow direction in the valve Mount the ball valve according to the attached examples in the piping system and take care of the flow direction! PRECISION RESULTS INNOVATION - PRODUCTION Seite- 2 -

Intended Use: The control unit will bring your pool water to the preset temperature via the collectors (absorbers), provided that the available solar irradiation is sufficient. Any use other than the intended one is not allowed! General: PRAHER solar controls are technologically advanced products that are manufactured with high precision and according to the most up-to-date production methods. Should nevertheless justified complaints exist, these are being resolved by us as quick as possible. Warranty: In case there is a justified complaint always tells us the PRAHER serial number of the valve (number is laser printed in the lid). We do reserve the right for technical modifications in the light of the improvement of our products without giving any notification. For this device a warranty period according to the valid EU regulations applies. The day the product is delivered shall be deemed as the beginning of the warranty period.! All important parts are sealed!! Damaged sealed parts lead to expires of the warranty Installation: The device is delivered ready-to-plug-in and therefore does not have to be opened by customer prior to use. For installation and wiring we recommend separate cable ducts. These must not be laid together with the motor wiring. Should an extension of the cable be necessary, cut the cable at the correct spot and extend by using a clamp distributor up to max. 30m with 1,5mm² cross section. Both temperature sensors are galvanically separated from the main voltage. The device works in every position, however, it is recommended not to mount it actuator facing downwards. PRECISION RESULTS INNOVATION - PRODUCTION Seite- 3 -

Schematic Diagram: Rot While mounting the sensors take care that the relative sensor should be located as close as possible to the medium (for example water)! Red Blue Blau SC03 M Mounting the Pool sensor (Blue): Mount the pool sensor as closes to the pool as possible. De-pressurise the piping system and empty thoroughly.. 10mm Mounting the Collector sensor (Red): drill O-Ring, sealing element Mount the Collector sensor (red) as close as possible to the manifold of the collector and make sure that the collector sensor is exposed to direct solar radiation and can not be manipulated by the shade (i.e. trees, buildings). If shade interferes, the solar radiation cannot be used to the maximum. CAUTION: Due to the arrangement of the sensors in the system slight difference between the setand the real Pool temperature may occur. PRECISION RESULTS INNOVATION - PRODUCTION Seite- 4 -

Start-UP: After plugging in the control unit the GEEN - LED [1] for POWER (in operation) is illuminated; the device is ready for operation. The ball valve operates on position 1 The terminals [a - b] are open. (Flow direction of the pool water) If the pool temperature sinks by more than 1,5 C be low the set pool temperature [3] and the collector temperature rises by more than 4 C above the pool temperature [3], the valve automatically switches over to heating and turns to position 2. The RED - LED [2] is illuminated. The terminals [a - b] are switched through. (Flow direction of the pool water) 2 4 1 5 3 [1] Control LED POWER [2] Control LED HEATING [3] Potentiometer Setting Temperature [4] Serial number [5] Hand emergency manipulation, optical position indication PRECISION RESULTS INNOVATION - PRODUCTION Seite- 5 -

NOTE: It is possible to reverse the position of the ball valve at solar operation for system-dependent appliances! Just switch over the inside slide switch from S1 to S2. See schematic diagram. Normal Operation (Delivered like this) Special Operation S2 S1 S2 S1 Schematic diagram at solar operation slide switch on S1: Schematic diagram at solar operation slide switch on S2: PRECISION RESULTS INNOVATION - PRODUCTION Seite- 6 -

Electrical connections: Usage Instructions Supply voltage: L1 N 12-34V DC 12-230V AC 50/60Hz Potential freely output: a b Zero potential I max. 300mA/250 VAC Zero potential: Switches at solar operated, for control solar pump, externally controls Filter clock override e.g. CS100, CS300 Technical Specifications: Voltage: 12-34VDC 12-230VAC 50/60Hz Power consumption: max.1,5 Watt 12-34V DC max. 60 Watt 12-230V AC 50/60Hz Protection rate: IP 54 Ambient temperature: max. 0 C 50 C Temperature difference Between Pool- and Collector sensor: Hysteresis pool temperature: max. 1,5 C T approx 4 C. This product complies to following EU- Guidelines: Electromagnetic Compatibility 89/336/EEC Low voltage guideline 73/23/EEC EMV ÖVE EN 60801-2 EN 50081-1 EN50082-1 EN600335-1 EN 55014 PRECISION RESULTS INNOVATION - PRODUCTION Seite- 7 -

Connection types: Usage Instructions Operate a solar pump: Filter clock override: PRECISION RESULTS INNOVATION - PRODUCTION Seite- 8 -

Parts catalog: 1 2 15 4 8 3 6 9 7 10 12 13 11 14 Spare Parts List Pos. Part Description Ref. No. 1 Actuator 6V DC MVO 141651 10 Circuit board EO510,12-230V AC/DC 31326 8 Pool sensor (Blue) 31338 15 Collector sensor (Red) 31335 1-15 Available on request PRECISION RESULTS INNOVATION - PRODUCTION Seite- 9 -

Dimensions: DN d D C Y H I E A Z t mm 32 40 101,0 81 84,5 220,0 154 200,0 162,0 169,0 27,5 mm 40 50 101,0 81 85,5 220,0 154 200,0 162,0 171,0 31.5 Failure Cause: POWER LED is not illuminated: - check supply voltage - is the device plugged in? Pool water is not warming at solar operation: - filter pump is switched off Control unit does not switch to heating operation: - Sensor is not optimally located or defect Control unit does not end the heating operation: - Sensor is not optimally located or defect PRAHER VALVES Tel.: ++43 / (0) 72 62 / 61 178 0* Fax: ++43 / (0) 72 62 / 61 203 austria@praher.com ; PRECISION RESULTS INNOVATION - PRODUCTION Seite- 10 -

PRECISION RESULTS INNOVATION - PRODUCTION Seite- 11 -