Report Issued: October 19, 2014 Project No.: 23942

Similar documents
Laboratory Evaluation Report for: Backflow Preventer for Beverage Dispensing Equipment

Recordkeeping Requirements of the Federal Motor Carrier Safety Regulations

PFI Quality Assurance/Quality Control (QA/QC) Program for Residential/Commercial Densified Fuels

This is a new permit condition titled, "2D.1111 Subpart ZZZZ, Part 63 (Existing Non-Emergency nonblack start CI > 500 brake HP)"

Example Notification of Compliance Status Report a

Tune-up Information. Owners and operators of all biomass-fired and oil-fired area source boilers.

Federal Railroad Administration, DOT CFR section Description Guideline PART 179

for the DOT Safety Audit (SA) Compliance Review (CR) or New CSA Streamlined Review (SR)

Applicable Requirements - NSPS Subpart JJJJ

Laboratory Evaluation Report for: Laboratory Faucet Backflow Preventer

Draft Outline for NTE GTR September 8, 2004

EVALUATION SUBJECT: EPA WATERSENSE SHOWERHEADS

American Society of Sanitary Engineering PRODUCT (SEAL) LISTING PROGRAM

Example Petition for Exemption

Importing Motor Vehicles into the United States

What to Expect in a DOT Drug & Alcohol Audit

Electrical Power Generator Use and Procurement Guidance

E/ECE/324/Rev.2/Add.102/Rev.1 E/ECE/TRANS/505/Rev.2/Add.102/Rev.1

STANDARD REVIEW PLAN

SFI SPECIFICATION 15.4 EFFECTIVE: JULY 20, 2010 * PRODUCT: Top Fuel and Funny Car Drag Race Drive Beadlock Wheels

LYCOMING ENGINES

[Docket No. FAA ; Directorate Identifier 2006-NE-20-AD; Amendment ; AD ]

John M. Seidl - (262) DOT Consultant & Insurance Agent

DRIVER QUALIFICATION FILE CHECKLIST

600 Amp Surge Arrester

STANDARD FOR TESTING AND RATING PERFORMANCE OF PRESSURE WASHERS: DETERMINATION OF PRESSURE AND WATER FLOW

CSC Transportation LLC Job Description Semi Tractor-Trailer Driver

ASME B31.8 INTERPRETATIONS VOLUME 13

RICE NESHAP Implementation. Ray Lukkarinen, P.E. Stanley Consultants, Inc.

SFI SPECIFICATION 6.1 EFFECTIVE: FEBRUARY 26, 2014 *

[Docket No. FAA ; Directorate Identifier 2016-NE-09-AD] Airworthiness Directives; Pratt & Whitney Division Turbofan Engines

Appendix C SIP Creditable Incentive-Based Emission Reductions Moderate Area Plan for the 2012 PM2.5 Standard

Specifications. MOEN 3/4 Thermostatic Vertical Spa

JB ENGINEERING AND CODE CONSULTING, P.C Cardinal Drive Munster, IN Phone: Fax:

Effective Date: June Rev. 3/26/2018- Void After: June Product: Plumbing Fixture Fittings File No. 4617

Troubleshooting Procedure for a Defective Fuel Pump

E/ECE/324/Add.5/Rev.6/Amend.2 E/ECE/TRANS/505/Add.5/Rev.6/Amend.2

Exhibit 5. Vapor to Liquid Volume Ratio (Executive Orders VR-201-F and VR-202-F) (Healy Model 900 EVR Nozzle)

BOMBARDIER, INC.

RICE NESHAP Frequently Asked Questions (FAQ)

United States Stove Company Project # Model: KP60 AKA: AP60, VG60 Type: Pellet-Fired Room Heater May 31, 2018

SFI SPECIFICATION 1.1 EFFECTIVE: NOVEMBER 9, 2001 *

KOHL S TE ST P ROTOCOL Approved: May 10, 2017

Energy Performance Information Request Timeline

Compatibility Between Electric Trains and Electrification Systems

RESOLUTION MEPC.278(70) (Adopted on 28 October 2016) AMENDMENTS TO THE ANNEX OF THE PROTOCOL OF 1997 TO AMEND THE INTERNATIONAL CONVENTION FOR THE

Registration, Recordkeeping, and Reporting Requirements

IGNITION INTERLOCK SERVICE CENTER RENEWAL LICENSE

RICE NESHAP Requirements for Stationary Engines at Area Sources of Hazardous Air Pollutants 1

SFI SPECIFICATION 1.2 EFFECTIVE: FEBRUARY 9, 2006* PRODUCT: Multiple Disc Clutch Assemblies for Vehicles with Naturally Aspirated Engines

STUDIO S BATH ACCESSORIES TOWEL BARS

GENERAL PLAN APPROVAL AND GENERAL OPERATING PERMIT BAQ-GPA/GP 2 STORAGE TANKS FOR VOLATILE ORGANIC LIQUIDS

FMCSA Brake Regulations 101

Public Service Company of Colorado THE SOURCE TO WHICH THIS PERMIT APPLIES IS DESCRIBED AND LOCATED AS FOLLOWS:

POWERED INDUSTRIAL TRUCK PROGRAM September 2015

REPORT NO. TR-P NC SAFETY COMPLIANCE TESTING FOR FMVSS 223 REAR IMPACT GUARDS 2007 TRANSFREIGHT TECHNOLOGY NHTSA NO.

National Board Update

5. Effective Date: On the first day of the first quarter, after applicable regulatory approval.

Report Number: G CRT-001A Model Number: Ionflow 50 Surface ARB Number: 1334

SFI SPECIFICATION 1.3 EFFECTIVE: MAY 23, 2000 * PRODUCT: Nitro-Methane Drag Race Multiple Disc Clutch Assemblies

WPERC Irrigation Engine Rebate Program Rules

(Addendum to the March 1994 Evaluation) March 11, 1999

Part 70 Operating Permit Amendment

Re: Online Reporting of Backflow Assembly Tests and Updates to Backflow Tester Records

Foyers Supreme Inc. Fireplace Products Project # 019-S Model: Fusion Type: Residential Wood Fired Heater February 19, 2016

Changes to EPA s AST & UST Rules. Mott-Smith Consulting Group, LLC

Test Report No: EEC18/01 dated August 02, 2018

COMMERCIAL DRIVER APPLICATION

RULE STATIONARY GAS TURBINES Adopted (Amended , ) INDEX

United States Stove Company Project # Model: Breckwell SP1000 Type: Pellet-Fired Room Heater July 25, 2018

LA Association of School Transportation Officials

Effective Date: May 2018 Void After: May Product: Flexible Water Connectors File No. 5747

SFI SPECIFICATION 49.2 EFFECTIVE: MARCH 22, 2011 *

REPORT. Lab Number: (5105) Page 1 of 1. Index

RICE NESHAP RECORD KEEPING Stationary Engines

BMW of North America, LLC, Grant of Petition for Decision of. AGENCY: National Highway Traffic Safety Administration (NHTSA),

Long Combination Vehicle (LCV) Exemption Permit Application

MSC Guidelines for Fired Thermal Fluid Heaters Procedure Number: E1-28 Revision Date: 06/11/2014

SOUTH AFRICAN NATIONAL STANDARD

v. CRIMINAL INFORMATION Fed. R. Crim. P. 7 COOPERATIVE SUCCESS MARITIME S.A.

ROLLS-ROYCE CORPORATION (FORMERLY ALLISON ENGINE COMPANY)

SFI SPECIFICATION 6.3 EFFECTIVE: FEBRUARY 26, 2014 *

ANNEX 3. RESOLUTION MEPC.278(70) (Adopted on 28 October 2016)

Artist: Address: Phone:

1996, or for which modification is commenced on or before March 16, 1998, shall not exceed the

Re: Notice of Tow Truck Committee Hearing before the City of Baytown' s Tow Truck Committee October 19, 2015 at 5: 30 p.m.

SGS North America, Inc.: Grant of Expansion of Recognition. AGENCY: Occupational Safety and Health Administration (OSHA), Labor.

Industrial, Commercial and Institutional Boilers at Area Source Facilities (Boiler GACT) Final Reconsidered Rule Requirements Summary

Specifications CRITICAL DIMENSIONS. MONTICELLO MOENTROL with Built-In 3 Function Transfer Valve Trim

Department of Agriculture Weights and Measures Services Division MAY 9, 2017

ANSI/BIFMA X Desk/Table Products - Tests. American National Standard for Office and Institutional Furnishings

PART 665 BUS TESTING. Subpart A General. 49 CFR Ch. VI ( Edition)

WORKSHOP REPORT. No, the RICE NESHAP applies only to stationary engines as defined in 40 CFR

The material incorporated by reference may be examined also at any state publications library.

TITLE 165. CORPORATION COMMISSION CHAPTER 16. ANTIFREEZE EFFECTIVE SEPTEMBER 11, 2017

MARKING STANDARD FOR SPRAY NOZZLES USED WITH PORTABLE PRESSURE WASHERS

HOLY SPIRIT RCSRD NO.4 BUS DRIVER S GUIDE

City of Hammond Purchasing Department RFP # General Maintenance and Repair Service Contract City Generators

INVITATION TO BID. If you have any questions concerning this bid, you may call Elizabeth Hope at (912)

Woolworths Quality Assurance Softgoods Manual

Transcription:

Report Number: 1052-14017 Report Issued: October 19, 2014 Project No.: 23942 Client: Showerstart LLC 15354 North 83 rd Way Suite 102 Scottsdale, AZ 85260 Contact: Mr. Jason Swanson Source of Samples: The samples were sent by Showerstart LLC and received by IAPMO R&T Lab in good condition on September 22, 2014. Date of Testing: October 3, 2014 through October 16, 2014 Sample Description: Various showerheads Models: See Page 2 Scope of Testing: The purpose of the testing was to determine if the samples tested of the showerheads met the applicable requirements of EPA WaterSense Specification for Showerheads (Version 1.0, March 4, 2010 Edition). Conclusion: The samples tested of the showerheads, models as listed on Page 2, from Showerstart LLC COMPLIED with the applicable requirements of EPA WaterSense Specification for Showerheads (Version 1.0, March 4, 2010 Edition). Note: Section 2.1 (ASME A112.18.1-2012/CSA B125.1-12 requirements) was tested under IAPMO R&T Lab report Nos. 1052-14015 and 1052-14016. I understand that intentionally submitting false information to the U.S. government or its agent is a criminal violation of the False Statements Act, Title 18 U.S.C. section 1001. By our signatures below we certify that all the testing and sample preparation for this report was performed under continuous, direct supervision of IAPMO R&T Lab, unless otherwise stated. Tested by, Reviewed by, Simon Hadi, Test Technician Andy Ho, Manager, Fitting Testing SH: ah Page 1 of 14

Model List: Model No. Description Remark EV3010-CP150-BP 1.5 gpm Single Function Showerhead Bulk Package EV3010-CP150-SB 1.5 gpm Single Function Showerhead Shipper Box EV3011-CP150-BP 1.5 gpm Single Function Showerhead with ShowerStart TSV Bulk Package EV3011-CP150-SB 1.5 gpm Single Function Showerhead with ShowerStart TSV Shipper Box EV3020-CP150-BP 1.5 gpm Multifunction Showerhead Bulk Package EV3020-CP150-SB 1.5 gpm Multifunction Showerhead Shipper Box EV3021-CP150-BP 1.5 gpm Multifunction Showerhead with ShowerStart TSV Bulk Package EV3021-CP150-SB 1.5 gpm Multifunction Showerhead with ShowerStart TSV Shipper Box EV3010-CP175-BP 1.75 gpm Single Function Showerhead Bulk Package EV3010-CP175-SB 1.75 gpm Single Function Showerhead Shipper Box EV3011-CP175-BP 1.75 gpm Single Function Showerhead with ShowerStart TSV Bulk Package EV3011-CP175-SB 1.75 gpm Single Function Showerhead with ShowerStart TSV Shipper Box EV3020-CP175-BP 1.75 gpm Multifunction Showerhead Bulk Package EV3020-CP175-SB 1.75 gpm Multifunction Showerhead Shipper Box EV3021-CP175-BP 1.75 gpm Multifunction Showerhead with ShowerStart TSV Bulk Package EV3021-CP175-SB 1.75 gpm Multifunction Showerhead with ShowerStart TSV Shipper Box EV3010-CP200-BP 2.0 gpm Single Function Showerhead Bulk Package EV3010-CP200-SB 2.0 gpm Single Function Showerhead Shipper Box EV3011-CP200-BP 2.0 gpm Single Function Showerhead with ShowerStart TSV Bulk Package EV3011-CP200-SB 2.0 gpm Single Function Showerhead with ShowerStart TSV Shipper Box EV3020-CP200-BP 2.0 gpm Multifunction Showerhead Bulk Package EV3020-CP200-SB 2.0 gpm Multifunction Showerhead Shipper Box EV3021-CP200-BP 2.0 gpm Multifunction Showerhead with ShowerStart TSV Bulk Package EV3021-CP200-SB 2.0 gpm Multifunction Showerhead with ShowerStart TSV Shipper Box Note: Each showerhead has two packaging methods (BP = Bulk Package and SB = Shipper Box). ******** REMAINING OF THIS PAGE INTENTIONALLY LEFT BLANK ******** Report No. 1052-14017 Page 2 of 14

Primary Standard: EPA WaterSense Specification for Showerheads (Version 1.0, March 4, 2010 Edition), sections tested / evaluated: 2.0 General Requirements 3.0 Water-Efficiency Criteria 4.0 Spray Force Criteria 5.0 Spray Coverage Criteria 6.0 Marking Test Results: All tests and evaluations were conducted per the written procedures specified in the specification. EPA WaterSense Specification for Showerheads (Version 1.0, March 4, 2010 Edition) 2.0 General Requirements COMPLIED 2.1 The showerheads were tested to and conformed the applicable requirements in ASME A112.18.1-2012/CSA B125.1-12. Refer to IAPMO R&T Lab test report Nos. 1052-14015 and 1052-14016 for details. 2.2 For EV3020 and EV3021 Series: The showerheads had more than one mode and all modes met the maximum flow rate requirement outlined in Section 3.1.1 and at least one of the modes, as specified by the manufacturer, met all of the requirements outlined in this specification. NOT APPLICABLE for EV3010 and EV3011 Series The showerheads had only one mode. 2.3 The showerheads were not packaged, marked, or provided with instructions directing the user to an alternative water-use setting that would override the maximum flow rate, as established by the specification. The instruction related to the maintenance of the product, including changing or clearning the showerhead components, directed the user on how to return the product to its intended maximum flow rate. 3.0 Water-Efficiency Criteria COMPLIED 3.1 The flow rate of the showerheads was tested in accordance with the procedures in ASME A112.18.1-2012/CSA B125.1-12 and met the following criteria: 3.1.1The manufacturer specified a maximum flow rate value (rated flow) of the showerheads and this specified value was equal to or less than 2.0 gpm (7.6 L/min). Model EV3010-CP150 & EV3011-CP150 (Single Function) EV3020-CP150 & EV3021-CP150 (Multi Function) EV3010-CP175 & EV3011-CP175 (Single Function) EV3020-CP175 & EV3021-CP175 (Multi Function) EV3010-CP200 & EV3011-CP200 (Single Function) EV3020-CP200 & EV3021-CP200 (Multi Function) Maximum Specified Flow Rate 1.5 gpm (5.7 L/min) 1.75 gpm (6.6 L/min) 2.0 gpm (7.6 L/min) Report No. 1052-14017 Page 3 of 14

3.1.2 The maximum flow rate (highest value) obtained through testing at flowing pressures of 20, 45 and 80 ± 1 psi did not exceed the maximum flow rate value specified in Section 3.1.1, when evaluated in accordance with 10 CFR 430 Subpart F, Appendix B, Step 6(b). See following tables. Finding: (Maximum Finding Flow Rate for Section 3.1.2) Model EV3010-CP150 Single Mode 1 1.31 1.34 1.32 2 1.31 1.33 1.30 3 1.30 1.37 1.34 4 1.31 1.36 1.34 20 psi 1.5 1.5 1.5 1.3 45 psi 1.5 1.5 1.5 1.4 80 psi 1.5 1.5 1.5 1.3 Model EV3011-CP150 Single Mode 1 1.29 1.36 1.34 2 1.18 1.28 1.22 3 1.29 1.32 1.30 4 1.27 1.32 1.32 20 psi 1.5 1.6 1.4 1.3 45 psi 1.5 1.6 1.4 1.3 80 psi 1.5 1.6 1.4 1.3 Model EV3020-CP150 Tested in Outer Spray Mode 1 1.29 1.31 1.28 2 1.39 1.34 1.31 3 1.28 1.30 1.28 4 1.32 1.32 1.30 Report No. 1052-14017 Page 4 of 14

Model EV3020-CP150 Tested in Outer Spray Mode (Continued): 20 psi 1.5 1.6 1.4 1.3 45 psi 1.5 1.5 1.5 1.3 80 psi 1.5 1.5 1.5 1.3 Model EV3021-CP150 Tested in Outer Spray Mode 1 1.25 1.27 1.21 2 1.17 1.19 1.16 3 1.21 1.28 1.32 4 1.26 1.31 1.36 20 psi 1.5 1.6 1.4 1.2 45 psi 1.5 1.6 1.4 1.3 80 psi 1.5 1.7 1.3 1.3 Model EV3010-CP175 Single Mode 1 1.46 1.54 1.52 2 1.46 1.50 1.47 3 1.43 1.52 1.47 4 1.36 1.55 1.53 20 psi 1.75 1.8 1.7 1.4 45 psi 1.75 1.8 1.7 1.5 80 psi 1.75 1.8 1.7 1.5 Model EV3011-CP175 Single Mode 1 1.45 1.48 1.48 2 1.38 1.46 1.42 3 1.52 1.56 1.54 4 1.40 1.49 1.48 Report No. 1052-14017 Page 5 of 14

Model EV3011-CP175 Single Mode (Continued): 20 psi 1.75 1.8 1.7 1.4 45 psi 1.75 1.8 1.7 1.5 80 psi 1.75 1.8 1.7 1.5 Model EV3020-CP175 Tested in Outer Spray Mode 1 1.55 1.57 1.60 2 1.57 1.56 1.58 3 1.54 1.54 1.56 4 1.56 1.54 1.56 20 psi 1.75 1.8 1.7 1.6 45 psi 1.75 1.8 1.7 1.6 80 psi 1.75 1.8 1.7 1.6 Model EV3021-CP175 Tested in Outer Spray Mode 1 1.38 1.50 1.53 2 1.41 1.50 1.51 3 1.46 1.53 1.58 4 1.39 1.51 1.57 20 psi 1.75 1.8 1.7 1.4 45 psi 1.75 1.8 1.7 1.5 80 psi 1.75 1.8 1.7 1.6 Model EV3010-CP200 Single Mode 1 1.51 1.78 1.81 2 1.52 1.80 1.84 3 1.52 1.83 1.87 4 1.46 1.76 1.78 Report No. 1052-14017 Page 6 of 14

Model EV3010-CP200 Single Mode (Continued): 20 psi 2.0 2.1 1.9 1.5 45 psi 2.0 2.1 1.9 1.8 80 psi 2.0 2.1 1.9 1.8 Model EV3011-CP200 Single Mode 1 1.63 1.78 1.88 2 1.68 1.82 1.90 3 1.68 1.80 1.93 4 1.72 1.86 1.93 20 psi 2.0 2.1 1.9 1.7 45 psi 2.0 2.1 1.9 1.8 80 psi 2.0 2.0 2.0 1.9 Model EV3020-CP200 Tested in Outer Spray Mode 1 1.68 1.83 1.89 2 1.60 1.80 1.86 3 1.35 1.68 1.76 4 1.62 1.82 1.92 20 psi 2.0 2.3 1.7 1.6 45 psi 2.0 2.1 1.9 1.8 80 psi 2.0 2.1 1.9 1.9 Model EV3021-CP200 Tested in Outer Spray Mode 1 1.47 1.73 1.86 2 1.49 1.75 1.90 3 1.50 1.71 1.89 4 1.50 1.74 1.90 Report No. 1052-14017 Page 7 of 14

Model EV3021-CP200 Tested in Outer Spray Mode (Continued): 20 psi 2.0 2.0 2.0 1.5 45 psi 2.0 2.0 2.0 1.7 80 psi 2.0 2.0 2.0 1.9 3.1.3 The minimum flow rate, determined through testing at a flowing pressure of 20 ± 1 psi and when evaluated in accordance with 10 CFR 430 Subpart F, Appendix B, Step 6(a), was not less than 60% of the maximum flow rate value specified in Section 3.1.1. See following tables. 3.1.4 The minimum flow rate (lowest value) obtained through testing at flowing pressures of 45 and 80 ± 1 psi was not less than 75% of the maximum flow rate value specified in Section 3.1.1, when evaluated in accordance with 10 CFR 430 Subpart F, Appendix B, Step 6(a). See following tables. Finding: (For Sections 3.1.3 and 3.1.4) Model EV3010-CP150 Single Mode Specified Flow Rate 20 psi 0.9 0.9 0.9 1.3 86.7% 45 psi 1.1 1.2 1.1 1.4 93.3% 80 psi 1.1 1.2 1.1 1.3 86.7% Model EV3011-CP150 Single Mode Specified Flow Rate 20 psi 0.9 1.0 0.8 1.3 86.7% 45 psi 1.1 1.2 1.1 1.3 86.7% 80 psi 1.1 1.2 1.0 1.3 86.7% Model EV3020-CP150 Tested in Outer Spray Mode Specified Flow Rate 20 psi 0.9 1.0 0.8 1.3 86.7% 45 psi 1.1 1.2 1.1 1.3 86.7% 80 psi 1.1 1.2 1.1 1.3 86.7% Model EV3021-CP150 Tested in Outer Spray Mode Specified Flow Rate 20 psi 0.9 1.0 0.8 1.2 80.0% 45 psi 1.1 1.2 1.0 1.3 86.7% 80 psi 1.1 1.3 1.0 1.3 86.7% Report No. 1052-14017 Page 8 of 14

Model EV3010-CP175 Single Mode Specified Flow Rate 20 psi 1.1 1.1 1.0 1.4 80.0% 45 psi 1.3 1.3 1.3 1.5 85.7% 80 psi 1.3 1.4 1.2 1.5 85.7% Model EV3011-CP175 Single Mode Specified Flow Rate 20 psi 1.1 1.1 1.0 1.4 80.0% 45 psi 1.3 1.4 1.2 1.5 85.7% 80 psi 1.3 1.4 1.2 1.5 85.7% Model EV3020-CP175 Tested in Outer Spray Mode Specified Flow Rate 20 psi 1.1 1.1 1.0 1.6 91.4% 45 psi 1.3 1.3 1.3 1.6 91.4% 80 psi 1.3 1.3 1.3 1.6 91.4% Model EV3021-CP175 Tested in Outer Spray Mode Specified Flow Rate 20 psi 1.1 1.1 1.0 1.4 80.0% 45 psi 1.3 1.3 1.3 1.5 85.7% 80 psi 1.3 1.4 1.2 1.6 91.4% Model EV3010-CP200 Single Mode Specified Flow Rate 20 psi 1.2 1.3 1.1 1.5 75.0% 45 psi 1.5 1.6 1.4 1.8 90.0% 80 psi 1.5 1.6 1.4 1.8 90.0% Model EV3011-CP200 Single Mode Specified Flow Rate 20 psi 1.2 1.3 1.1 1.7 85.0% 45 psi 1.5 1.6 1.4 1.8 90.0% 80 psi 1.5 1.5 1.5 1.9 95.0% Report No. 1052-14017 Page 9 of 14

Model EV3020-CP200 Tested in Outer Spray Mode Specified Flow Rate 20 psi 1.2 1.5 0.9 1.6 80.0% 45 psi 1.5 1.6 1.4 1.8 90.0% 80 psi 1.5 1.6 1.4 1.9 95.0% Model EV3021-CP200 Tested in Outer Spray Mode Specified Flow Rate 20 psi 1.2 1.2 1.2 1.5 75.0% 45 psi 1.5 1.5 1.5 1.7 85.0% 80 psi 1.5 1.5 1.5 1.9 95.0% 4.0 Spray Force Criteria COMPLIED 4.1 The spray force of the showerheads was tested in accordance with the procedures outlined in Appendix A and met the following criteria: 4.1.1 The minimum spray force was not less than 2.0 ounces at a pressure of 20 ± 1 psi at the inlet when water was flowing. Finding: Model Test Mode Spray Force Status EV3010-CP150 Single > 2.0 ounces Passed EV3011-CP150 Single > 2.0 ounces Passed EV3020-CP150 Outer Spray > 2.0 ounces Passed EV3021-CP150 Outer Spray > 2.0 ounces Passed EV3010-CP175 Single > 2.0 ounces Passed EV3011-CP175 Single > 2.0 ounces Passed EV3020-CP175 Outer Spray > 2.0 ounces Passed EV3021-CP175 Outer Spray > 2.0 ounces Passed EV3010-CP200 Single > 2.0 ounces Passed EV3011-CP200 Single > 2.0 ounces Passed EV3020-CP200 Outer Spray > 2.0 ounces Passed EV3021-CP200 Outer Spray > 2.0 ounces Passed 5.0 Spray Coverage Criteria COMPLIED 5.1 The spray coverage of the showerheads was tested in accordance with the procedures outlined in Appendix B and met the following criteria: 5.1.1 The total combined maximum volume of water collected in the 2- and 4- inch annular rings did not exceed 75% of the total volume of water collected, and; Report No. 1052-14017 Page 10 of 14

5.1.2 The total combined minmum volume of water collected in the 2-, 4-, and 6-inch annular rings was not less than 25% of the total volume of water collected. Finding: (For Sections 5.1.1 and 5.1.2) Model EV3010-CP150 Single Mode 0.209 0.451 0.631 0.004 1.30 1.30 0.0% 16.1% 34.8% 48.7% 0.3% 51.0% 99.7% Model EV3011-CP150 Single Mode 0.145 0.588 0.569 0.000 1.30 1.31 0.8% 11.2% 45.2% 43.7% 0.0% 56.3% 100.0% Model EV3020-CP150 Tested in Outer Spray Mode 0.030 0.733 0.502 0.000 1.27 1.28 0.8% 2.4% 58.0% 39.7% 0.0% 60.3% 100.0% Model EV3021-CP150 Tested in Outer Spray Mode 0.064 0.594 0.571 0.000 1.23 1.24 0.8% 5.2% 48.3% 46.5% 0.0% 53.5% 100.0% Report No. 1052-14017 Page 11 of 14

Model EV3010-CP175 Single Mode 0.140 0.546 0.767 0.007 1.46 1.47 0.7% 9.6% 37.4% 52.5% 0.5% 47.0% 99.5% Model EV3011-CP175 Single Mode 0.200 0.508 0.742 0.000 1.45 1.46 0.7% 13.8% 35.0% 51.2% 0.0% 48.8% 100.0% Model EV3020-CP175 Tested in Outer Spray Mode 0.110 0.959 0.431 0.000 1.50 1.51 0.7% 7.4% 63.9% 28.7% 0.0% 71.3% 100.0% Model EV3021-CP175 Tested in Outer Spray Mode 0.134 0.705 0.634 0.000 1.47 1.48 0.7% 9.1% 47.8% 43.0% 0.0% 57.0% 100.0% Model EV3010-CP200 Single Mode 0.167 0.657 0.886 0.000 1.71 1.72 0.6% Report No. 1052-14017 Page 12 of 14

Model EV3010-CP200 Single Mode (Continued): 9.8% 38.4% 51.8% 0.0% 48.2% 100.0% Model EV3011-CP200 Single Mode 0.212 0.729 0.838 0.013 1.79 1.80 0.6% 11.9% 40.7% 46.8% 0.7% 52.5% 99.3% Model EV3020-CP200 Tested in Outer Spray Mode 0.083 0.766 0.886 0.000 1.73 1.74 0.6% 4.8% 44.2% 51.1% 0.0% 48.9% 100.0% Model EV3021-CP200 Tested in Outer Spray Mode 0.066 0.749 0.867 0.000 1.68 1.70 1.2% 3.9% 44.5% 51.5% 0.0% 48.5% 100.0% 6.0 Marking COMPLIED (Per manufacturer s provided marking drawings and package artworks) 6.1 The products will be marked with the maximum flow rate value in gpm and L/min as specified by the manufacturer, verified through testing and in compliance with this specification. 6.2 The product packaging will be marked with the maximum flow rate value in gpm and L/min as specified by the manufacturer, verified through testing and in compliance with this specification. Report No. 1052-14017 Page 13 of 14

6.3 The product packaging will be marked with the minimum flow rate value in gpm and L/min at 45 psi, calculated in Section 3.1.4 as 75 percent of the manufacturer s specified maximum flow rate value, verified through testing and in compliance with this specification. 6.4 The flow rate marking will be in gpm and L/min in 2 or 3 digit resolutions. Photographs of Samples Tested: EV3010 Series (1.5, 1.75 & 2.0 gpm) EV3020 Series (1.5, 1.75 & 2.0 gpm) EV3011 Series (1.5, 1.75 & 2.0 gpm) EV3021 Series (1.5, 1.75 & 2.0 gpm) Report No. 1052-14017 Page 14 of 14