GENERAL ELECTRIC CONCEALED CHILLED WATER FAN COIL UNITS

Similar documents
GENERAL ELECTRIC FAN COIL UNITS

Product Data. Features/Benefits. 42BH System Fan Coil. 800 to 4000 Cfm

48CWA2-00 Chilled Water Fan Coil With or Without Electric Heat 2-Pipe Heat / Cool Fan Coil 48,000 BTUH

Chilled Water FCU. Horizontal Fan Coil 50hz CFM. A Series.

42CET/ 42CED Series Chilled Water Fan Coil Unit Furred-in Ceiling Model 300 to 1400 cfm Electric heater option

36CWA4-HW 4-Pipe Chilled & Hot Water Air Handler (120V) 4-Pipe Heat & Cool Fan Coil 36,000 BTUH

24CWA4-HW 4-Pipe Chilled & Hot Water Air Handler (120V)

Commercial Blower Coil Air Handlers

Guide Specifications. General. Casing. Coil/Drain pan. Fan/Motor

FCVC Series VERTICAL FAN COILS

CFFWA Chilled/Hot Water Universal Mount Fan Coil 2-Pipe Heat / Cool Fan Coil 12,000-60,000 BTUH

Product Data. 42D Ducted Fan Coil Air Conditioners cfm

HBC SERIES-PSC MOTOR HBCX SERIES-ECM MOTOR

Concealed Ducted Split Series R22

MHWW-24-H-1 Chilled/Hot Water Hi-Wall Fan Coil. Heat / Cool Fan Coil 24,000 BTUH. Rev. 1.3

42C/D SERIES Ducted Chilled Water Fan Coil Unit With District Cooling Application

MH1WC4W-08-1-B Chilled/Hot Water 1-Way Cassette Fan Coil

The World Leading Air-conditioning Company

Vertical Hi-Rise Fan Coil Unit (Model FS)

Complete HVAC Capability

technical sales guide - 60Hz Ducted Split Units HIGH AMBIENT OPERATION 52 UPTO

Fan Coil Units POWERED BY KLIMAK ITALY

LOW STATIC FAN COIL UNITS District Cooling Chilled Water Application

ROOF TOP (SERIES SR) 10.8 TO 103 KW 37,000 TO 351,000 Btuh

The Premium Quality Fan Coil Units for Horizontal Application Hydronic or Electric Heat

CHILLED WATER FAN-COIL UNITS

Technical Sales Guide # 040 YDFC 0 1 Page 2

HBC SERIES-PSC MOTOR HBCX SERIES-ECM MOTOR

A Division of Nailor International Inc. ECONOMY AIR HANDLERS

Vertical Floor Fan Coil Unit (Model FW)

FN Fan-Coil Units High-Performance, Horizontal

FFW/FSW/FHW SERIES FLOOR EXPOSED VERTICAL FAN COIL UNITS

DECORATIVE FAN COIL UNIT DECORATIVE FAN COIL UNIT SPECIFICATIONS

VERTICAL SINGLE AND DOUBLE WALL BELT DRIVE AIR HANDLER DX OR CHILLED WATER COOLING WITH HOT WATER OR ELECTRIC HEAT

Submittal DIMENSIONS SIZE FAN SIZE L W H C D E F G J K [406] [508] 25 [635] [406] 16 [406] 16 [406] 39-1/2 [1003] 44-1/2 [1130] 51 [1295] 59 [1499]

TECHNICAL GUIDE GENERAL SPECIFICATIONS COMMERCIAL SPLIT-SYSTEM COOLING UNITS FOUR PIPE SYSTEM OUTDOOR UNIT:

BAC / BHC Product Specifications

Address: VTS Clima L.L.C.

R-22, 13 SEER 60 Hertz

High Performance Fan Coils FCHG Genesis Series Horizontal

BAC / BHC SERIES 6 to 20 Ton Air Handlers

D M S 760 C01 A A 1 1

INTRODUCTION CP 06 F C - A 4 L - F GENERAL DESCRIPTION DESIGN PARAMETER DUCTED CONCEALED WITH PLENUM. F - c/w Filter

High Static Pressure Duct Fan Coil Unit

WE MAKE INDOOR AIR BETTER

Submittal. Holder Construction Company. Reviewed. Reviewed as Noted. Rejected. 1. Updates per Bulletin #4

PHCD-Series. Catalog

WAC Air Curtains Technical Guide

Precision Cooling For Business-Critical Continuity. Liebert CW. System Design Manual kW, 50 & 60Hz

DIRECT-DRIVE BLOWER FAN COIL AIR CONDITIONER ENGINEERING GUIDE

DESCRIPTION ACCESSORIES FIELD INSTALLED SPLIT-SYSTEM EVAPORATOR BLOWERS KBBU060, KDBC090, KCBC120 & KCBC180 5 THRU 15 NOMINAL TONS SUPPLY AIR PLENUMS

SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS DESCRIPTION FEATURES H2CA300, 360, 480 & THRU 50 NOMINAL TONS

SUNLINE 2000 SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS FEATURES DESCRIPTION. H5CE090 & H3CE AND 10 NOMINAL TONS (World 50HZ)

High Static Fan Coil Units YDFC

Fan coil units. HFCE, HFXE, VFCE, VFXE series Sizes 03 to to 3400 m3/h UNT-PRC007-E4

VHIA High-Static Ducted Indoor Units - 60HZ

Hi-Performance Series Fan Coil Technical Catalog

PCB COMMERCIAL SERIES

Modular Variable Speed Air Handlers

BAC / BHC SERIES 6 to 20 Ton Air Handlers

TECHNICAL GUIDE R-410A, 13 SEER LATITUDE SERIES 60 Hertz

DAIKIN INDUSTRIES, LTD. Ceiling Concealed Chilled Water Fan Coil Unit (50Hz/60Hz)

YEAR-ROUND AIR CONDITIONING Our Deluxe-Aire units are ideally suited to provide heating, cooling and air filtration for areas where it is not

50 Hz AIR - COOLED SPLIT SYSTEM. Products That Perform...By People Who Care AIR CONDITIONERS WITH SCROLL COMPRESSORS

42HS Fan Coil Unit (High Static Pressure)

SINGLE PACKAGE AIR CONDITIONING WATER COOLED

M-SERIES MHP4 MODEL NUMBER GUIDE 3 M HP F P 1 ELECTRIC HEAT PUMP PACKAGED UNITS REVISION CODE

Chassis Access Fans Motors Speed Control Coils The Condensate Tray Insulation Spigots Controls Enclosure Control Valves Filters Rev A

TECHNICAL GUIDE DESCRIPTION MODELS: D4HH 024 THRU 180 HORIZONTAL FEATURES SINGLE PACKAGE AIR CONDITIONERS HORIZONTAL INDOOR & CONDENSER AIR FLOW

F SERIES. Floor Exposed Vertical Fan Coil Units. Nominal Sizes 200 thru 1200 CFM

Product Data. Features/Benefits. WEATHERMASTER 36S Water Control Induction Air Terminals to cfm (1770 to 8900 Btuh)

Horizontal Series Fan Coil Technical Catalog

TECHNICAL GUIDE R410a SPLIT SYSTEM 1.5 to 5.0 NOMINAL TONS

Product Data. FS3QX Slim Line Ducted Fan Coil With Plenum Sizes 018 thru 060 SLIM LINE DUCTED FAN COIL WITH PLENUM ON/OFF DISPLAY TEMP

CAS. Product Specifications. COMMERCIAL SPLIT SYSTEMS CONDENSING UNITS R 410A, 6 to 20 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE

HS17. HS17 SERIES CONDENSING UNITS 17.6 to 65.2 kw ( to Btuh) Cooling Capacity. MATCHED REMOTE SYSTEMS 50hz ENGINEERING DATA

APARTMENT FAN COILS AVAILABLE WITH FACTORY INSTALLED 5, 7, & 11 kw ELECTRIC HEAT, or NO HEAT R-410A and R-22 SYSTEMS

AIR HANDLERS RBHC- SERIES HEAT PUMP AIR HANDLERS AND FAN COIL UNIT

MODULAR SINGLE AND DOUBLE WALL BELT DRIVE AIR HANDLER DX OR CHILLED WATER COOLING HOT WATER OR ELECTRIC HEATING

University of Delaware

Product Data. FF1E Base Series Fan Coil Sizes 018 thru 036 FEATURES

VMDA Concealed Medium Static Ducted Indoor Models - 60HZ

BUILDING EFFICIENCY Energy Efficient Variable Speed EC Motor Fan Coil Unit Solutions Model YECFC

TECHNICAL GUIDE FLEXIBLE LIGHT COMMERCIAL UNIT CHAMPION SERIES (WORLD 50 HZ) SINGLE PACKAGE COOLING UNITS D1EB036, 048 AND 060 3, 4 & 5 NOMINAL TONS

PHB SERIES 7-1/2 and 10 TON

SUNLINE 2000 SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS DESCRIPTION FEATURES H4CE090 & H2CE120 & H1CE /2, 10, & 12-1/2 NOMINAL TONS

Product Data. Features/Benefits 50JS SINGLE-PACKAGED HEAT PUMP 50 HZ UNITS 7 TO 18 KW (2 TO 5 NOMINAL TONS)

APARTMENT FAN COILS AVAILABLE WITH FACTORY INSTALLED 5, 7, & 11 kw ELECTRIC HEAT, or NO HEAT R -22 SYSTEMS

42CLS-W Series Chilled Water Fan Coil Unit Ceiling Concealed - Duct Type Nominal: 400-2,000 CFM

S5BP Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS

Fan Coil Units. Technical Data ECDEN FWL-DT/DF

CUH Series. Cabinet Unit Heaters HEAT TRANSFER DIVISION

SPLIT-SYSTEM EVAPORATOR BLOWER DESCRIPTION ACCESSORIES EER 8.5 ARI RATINGS* K2ES120A25 10 NOMINAL TONS WITH TWO 5 TON CIRCUITS

Product Data. 40RUA 18.3 to 59.2 kw Direct Expansion Packaged Air---Handling Units 50 Hz

WATER SOURCE HEAT PUMPS

TECHNICAL GUIDE MODELS: RHP14J18 THRU 60 RHP SERIES SPLIT-SYSTEM HEAT PUMPS 14.5 SEER R-410A 1 PHASE 1.5 THRU 5 NOMINAL TONS DESCRIPTION FEATURES

SPECIFICATIONS AND DESIGN ARE SUBJECT TO CHANGE WITHOUT PRIOR NOTICE. EDITION 11

Typical Applications. Horizontal Installation

Product Data. Features/Benefits. 38HDL Cooling Only Condensing Unit. 1 1 / 2 to 5 Nominal Tons

Midea 50Hz AC Fan Coil Unit 2-Pipe Floor-standing Series Technical Service Manual

Transcription:

GENERAL ELECTRIC CONCEALED CHILLED WATER FAN COIL UNITS ACWL Series ACWL0 thru ACWL4 00 CFM thru 400 CFM GE_ACWL_series.indd 3// : PM

CONTENTS Model decoding 3 Unit features 3 Standard specifications 3-4 O ptions 4 Physical data 5 Cooling capacities -9 Fan performance data 0- Sound power data Hot water capacities Unit dimensions 3 Coil connection dimensions 4 Heater box dimensions & arrangements 5 Valve packages 5 Typical schematic wiring diagram - Installation E lectrical Maintenance 8 8 8 Continuing research results in steady improvements. Therefore, these specifications are subject to change without notice GE_ACWL_series.indd 3// : PM

DECODING,, 3 & 4 BASIC (SERIES) ACWL HORIZONTAL CONCEALED CHILLE D WATER FA N COIL UNITS 5 & SIZE (x 00 CFM) 0 03 04 0 08 0 4 ELECTRICAL SUPPLY (V-Ph-Hz) B : 0/40-- 8 COIL A : 3 ROW CHILLE D WATE R B : 4 ROW CHILLE D WATE R J : 3 ROW CHILLE D WATER + RO W HEATIN G 9 HEATER N : NO HEATER B : kw D : kw E : 3 kw F : 4 kw G: 5 kw N : NO HEATER D : kw E : 3 kw F : 4 kw G: 5 kw J : kw M: 0 kw 0 ACCESSORIES N : STANDARD B : 3D VALVE PACKAGE (COOL ONLY) K : 4D VALVE PACKAGE (HEAT & COOL ) FIN A : ALUMINUM FIN B : COATED ALUMINUM FI N C : COPPER FI N COIL CONNECTION R : R H SIDE, STANDARD (FACING AIR DISCHARGE) L : LH SIDE, OPTIONAL (FACING AIR DISCHARGE) 3 FILTER N : NONE A : ALUMINUM (/" THICK) C : SYNTHETIC (/" THICK) 4 OPTION N : STANDARD UNIT (WITHOUT THERMOSTAT ) T : UNIT WITH THERMOSTAT UNIT FEATURES LOW HEIGHT UNITS Good for spaces with low ceiling height. COMPACT DIMENSIONS Ideal to fit into tight spaces. EASY MAINTENANCE / ONE SIDE ACCESS Filters can be easily removed by sliding. Piping and controls are on one side for easy access. BACK AND BOTTOM RETURN AIR OPTIONS SINGLE COIL FOR RH & LH APPLICATIONS (FIELD CHANGEABLE FOR RH & LH APPLICATIONS) SPLIT COILS, CHILLED + HOT WATER OPTIONS VALVE PACKAGES FOR PIPE & 4 PIPE SYSTEMS WIDE RANGE OF HEATER SIZES QUIET, PULSE FREE AIR DELIVERY Centrifugal fans that are statically and dynamically balanced, handle up to 0.5 w.g. external static pressure allowing you to keep the unit away from your comfort zone. STANDARD SPECIFICATIONS UNIT CONSTRUCTION These units are fabricated of heavy gauge galvanized steel to ensure lasting durability and dependable performance with minimum maintenance. The panels are insulated to provide positive protection against sweating and maximum damping of air noise. This unit is designed for those concealed overhead installations which require supply ductwork. A duct collar is provided into the front panel for supply air duct connection. The standard arrangement provides return air from the rear side. This arrangement may be reversed to provide bottom return air by simply interchanging the bottom and rear panel. This reversal can be easily accomplished in the field. Access to the blower motor assembly is provided through the removable bottom panel from where the complete fan/motor can be removed for servicing. FANS The centrifugal, forward curved, double width fan wheels are statically and dynamically balanced for quiet and smooth performance. Blower housing is rugged galvanized steel to provide added rigidity and assure quiet & smooth operation. 3 GE_ACWL_series.indd 3 3// : PM

STANDARD SPECIFICATIONS MOTORS Motors are permanent split capacitor type with three speed windings and built-in thermal overload protection. The bearings are of sleeve type. FILTERS All models are furnished with / thick permanent washable type aluminum filters as standard. COILS Coils are 3/8 OD copper tubing, constructed of enhanced copper tubes and mechanically bonded to aluminum As fins. an option, corrugated copper fins or coated aluminum fins may be provided. Manual air vents are provided on all chilled water coils. The standard chilled water coil is 3 rows for all models & 4 row chilled water coil is also provided as an option. A 4 pipe coil consisting of 3 rows of cooling coil and row of heating coil is used for heating application. Each coil is pressure tested in the factory at not less than 300 psi (00 kpa) air pressure. Coils conform to ARI 40. DRAIN PAN The condensate drain pan is fabricated of 8 gauge galvanized steel. The drain pan is powder coat painted. The outer surface is thermally insulated. DRIP LIP The purpose of a drip-lip is to capture any condensate from the valve packages and direct it to the drain pan. It is fabricated of a single metal formed to fit on the side of the drain pan. They may be installed in the field and should always be pitched towards the drain pan to assure proper drainage. This will be supplied loose for field installations along with valve packages. OPTIONS ELECTRIC HEATERS The heater element is of the resistance open coil type. Thermal overheat cut-outs and fusible links are provided to shutoff power to heaters in case of airflow failure. VALVE PACKAGES Valve packages are available as an option (3D for two pipe system and 4D for four pipe systems). These valves can be factory installed or supplied loose for field installation. THERMOSTAT An attractive wall mount three speed electronic thermostat with all required functions and features for safe and smooth operation which can be used for cooling & heating requirements. 4 GE_ACWL_series.indd 4 3// : PM

PHYSICAL DATA NUMBER ACWL0 ACWL03 ACWL04 ACWL0 ACWL08 ACWL0 ACWL ACWL4 P OWE R S UP P LY, V-P h-hz 0/40-- BLOWER Type F orward Curve d Size (mm) 4x9 4x9 4x9 4x3 4x3 85x3 85x3 85x3 Quantity BLOWE R MOT OR Quantity F LA 0. 0. 0....5.5.5 Watts @ 0.0 ESP, high speed 8 08 5 0 38 35 390 COOLING COIL Type Corrugated Fin & Tube Tube dia. - Rows - FPI 3/8-3 - 4 3/8-3 - 4 3/8-3 - 4 3/8-3 - 4 3/8-3 - 4 3/8-3 - 4 3/8-3 - 4 3/8-3 - 4 Face area, Sq. ft. (Sq. m.).(0.3 ).(0.3 ).(0.3).(0.9).(0.9) 3.33(0.3) 3.33(0.3) 3.54(0.39) HOT WATER COIL Type Corrugated Fin & Tube Tube dia. - Rows - FPI 3/8 - - 4 3/8 - - 4 3/8 - - 4 3/8 - - 4 3/8 - - 4 3/8 - - 4 3/8 - - 4 3/8 - - 4 Face area, Sq. ft. (Sq. m.).(0.3 ).(0.3 ).(0.3).(0.9).(0.9) 3.33(0.3) 3.33(0.3) 3.54(0.39) COIL CONNECTIONS Chilled water, Inlet - Outlet (inch) 5/8-5/ 8 5/8-5/ 8 5/8-5/ 8 5/8-5/ 8 5/8-5/ 8 5/8-5/ 8 5/8-5/ 8 5/8-5/ 8 Hot water, Inlet - Outlet (inch) 5/8-5/ 8 5/8-5/ 8 5/8-5/ 8 5/8-5/ 8 5/8-5/ 8 5/8-5/ 8 5/8-5/ 8 5/8-5/ 8 DRAIN CONNECTIO N S ize (inch) /8 /8 /8 /8 /8 /8 /8 /8 RETURN AIR FILTER Size (inch) 8 x 3-3/8 8 x 3-3/8 8 x 3-3/8 8 x 9-5/8 8 x 9-5/8 0 x -/8 0 x -/8 0 x -/8 (/'' THICK) Quantity SHIPPING WEIGHT kg. (approx. ) 30 30 30 40 40 54 54 54 5 GE_ACWL_series.indd 5 3// : PM

CHILLED WATER COOLING CAPACITIES 3 ROW COIL (ENGLISH UNITS) ENTERING AIR TEMP. = 0 F DB/3 0 F WB (@ HIGH SPEED) ( 0 F) 8 0 UNIT 40 0 F EWT 45 0 F EWT 0 F EWT SIZE TC SC GPM TC SC GPM TC SC GPM 0 9.05.43..99 5.5.5 5. 4.88.9 03 9.99.8..8.5.95 5. 5.55.44 04 0.5.3.4 8.30..0.09 5.9.5 0 8.4 3. 3 4.0 4.3.45 3.58 0.4 0.. 08 0.8 4. 5.0 5.9.4 3.95.5 0.4.8 0 30..9 5.5 3.54 8.8 5.88. 0.49 4. 3.90.9.9 4.59 9.0.5.8.8 4.4 4 34.9 5.0 8.3.9.43.0 9.3 8. 4.84 0 8.4..3.8 5.39.3 5.0 4..00 03 9..9.93.0.0.5 5.5 5.40. 04 0.5.43.05 8.04.. 5.89 5..8 0.9. 3.54 3.83.. 0.0 9 9.8.0 08 9.5 4. 3.90 5..33 3.04.0 5 0.8. 0 9.0 0.9 5.8. 8. 4.5.4 0 5.94 3.8 30.3.9 5.0 3.58 9.0 4..0.8 3.4 4 33.08 3.8 9. 5.3 0.5 5.3 8.5 8.09 3.0 0 8.4.05.4. 5.9. 4.88 4. 0.8 03 9.44.83.5.40 5.9.3 5.40 5. 0.90 04 0.00...83.34.3 5.9 5.0 0.95 0.0.4.8 3.43 0.85.4 9.5 9.54.3 08 8.9 3. 9 3.5 4.3.99.45 0. 4 0.54. 0 8.3 0.3 5 4.9.8.5 3.5 5.8 0 5.4.3 9.35.3 0 4.89.8 8.45 3.80.4..4 4 3.9 3. 4 5.3 4.3 0.0 4.. 9..9 ENTERING AIR TEMP. = 80 0 F DB/ 0 F WB (@ HIGH SPEED) ( 0 F) 8 0 UNIT SIZE 40 0 F EWT TC SC GPM 45 0 F EWT TC SC GPM 0 F EWT TC SC GPM 0 4. 3 8.9 3.8.35.9 3.09 0.0 4.0.5 03.5 0.3 4.3 3.8 8.95 3.44.3.98.8 04.5 4 0.80 4.38 4.0 9.54 3.5.5 8..94 0 3.0 4 9.00. 5.9..4 0.58 4.4 5.4 08 34.4. 8. 8.38 8.55.09.59.38 5.5 0 5. 3.5 3. 9 43..93 0.8 34.3 5 4.48 8.59 55.3 33.8 3.8 4 45.9 9.3.3 35.8 4 5. 8.9 4. 3.4 5. 8 49.8 3..45 39. 8 8.0 9.8 0 3.90 8.5 0. 8..5.3 9.4 5.3.8 9 03 5.4 9.5 4 3.0 9.8 3 8.4.5 0.58.. 04.3 5 0.3 3. 3.53 8.93..3 8.9.4 0 8. 0.0 5.4 3. 5.5 4.3 9.40 4.0 3.88 08 3. 0 9.0.3. 8.35 5.53.43 5. 4.8 0 48. 0 9.58 9. 39.40 5.5.88 3.9 3.0.39. 30.98 0.0 5 4.05.9 8. 33.4 4.4.8 4 55. 8 33.9.0 3 44.95 9.44 8.99 3.4 3.39.8 0 3.9 8. 0. 0. 0..8 5 9. 5..5 4 03 4.55 9.0 3.4.4 8. 8.0 0.33.5. 04 5.4 9. 3.5 8 3. 8 8. 3. 0 0.95 8.0.8 0.. 4.4. 5.0 3.9 8.8 3.3 3.4 08 9. 3 8.49 4.94 5.4.8 4.9 0. 5.9 3.4 0 44.4 8.55.4 3.49 4..5 30.9.4 5.5 4.3 8.. 39.8 5.8.53 3. 3.55 5.38 4. 3.44 8.44 4. 8.. 35. 5.0 5.85 ENTERING AIR TEMP. = 84 0 F DB/ 0 F WB (@ HIGH SPEED) ( 0 F) 8 0 UNIT SIZE 40 0 F EWT TC SC GPM 45 0 F EWT TC SC GPM 0 F EWT TC SC GPM 0 0.84.8 5. 8. 0.4 4.5 5.9 9.8 3.95 03 3.5.8 3 5.89 0.0.5 5.5. 0.44 4.43 04 5. 3..9.95.33 5.49 8.8 5. 4. 0 45.3 4.5 5.3 39.9.8 9.80 33.45 9.3 8.3 08...9 43.9 4.5 3 0.95 3..99 9.30 0 8.3 4.5 5 9.8.5 3.4 3.88 5.08 33.5 4. 83. 44.9 5 0.8. 39.4 8. 59.9 35.0 4.9 9 4 9..0 3.5 8.9 43. 9.3.30 38.59.5 0 9.8 0. 9 3.94. 9.3 3.45 4.9 8.4.98 03.0.0 4.4 9.3 0.88 3.8. 9.8 3.3 04 3..8 4.0 0.5.0 4.0.5 9 0.5 3.5 0 4.0. 4 8.34 3. 0.35.4 30.9 3 8.35.9 08 4.39 5.3 9.8 40.4.9 8.03 34. 4 0.43.83 0.4 38. 4.3.33 34.3. 5.0 30.0 0.4 0 4.3 40. 8 4.95 4.30 3.0 5.8 54.4 3. 0.8 8 4 8. 44.9 0.5 0.8 39. 4. 59.80 35.33.9 0 8.9 0. 3 3.3.4 9.3.4 4. 8.3.3 03 0.9.4 9 3.49 8.30 0.3 3.05 5. 9.40. 04.. 3.0 9.35.0 3..5 4 9.98. 0 39..4 3.5 33.95 9. 5. 8.9 3.33 4.8 08 43.4 3.. 3.38..3 3. 9 9. 5.8 0 5.93 3.0 0.99 5.88 3.0 9.48 48.8 8. 8.03 9.0 3. 5. 59.43 33. 0 9.90. 30.09 8.3 4 5.93 4.4 9.5 5.3 3.8 0.8 55.00 3.90 9. NOTE: For any other conditions, please use selection so ware for fan coil units. Apart from capacities, this so ware provides; a) Sensible heat ratio b) Leaving air temperature (DB/WB) - 0 F c) Leaving water temperature - 0 F d) Leaving water velocities (FPM) e) Water pressure drop (feet of water) LEGEND: TC - Total Capacity (MBH) SC - Sensible Heat Capacity (MBH) - Water Temperature Rise ( 0 F) EWT - Entering Water Temperature ( 0 F) GPM - Water flow (Gallons Per Minute) GE_ACWL_series.indd 3// : PM

CHILLED WATER COOLING CAPACITIES 4 ROW COIL (ENGLISH UNITS) ENTERING AIR TEMP. = 0 F DB/3 0 F WB (@ HIGH SPEED) ( 0 F) 8 0 UNIT 40 0 F EWT 45 0 F EWT 0 F EWT SIZE TC SC GPM TC SC GPM TC SC GPM 0 0.5.30.3.99..00 5.8 5.34.4 03.9 8.39.98 9.08.09..9.4. 04. 8.9 3.5 9.4.58.4.09.. 0.0 5.5 5 5.53.8 3.03 4.. 0.4 3.05 08 4.3. 3.08 8.44 4.53 4. 3.4 3. 3.3 0 3.00 5.9 9.5.54.44.89 9.9 8 8.5 4.99 38.4. 9. 8.80.5.0 0.8 5 9.5 5. 4 4.40 9. 5 0.0 3.4 4.5 3.8.8. 5. 0 9.8.89.9.3 5.95.55 5. 5.3.4 03..9.4 8.8.9..48.09.30 04.9 8.49.38 9.35.38.8.8..3 0 0. 4. 4...5 3...09.35 08.8. 4.55.5 4.0 3.55.9.33.58 0 34.0 4.0 8.80.4 0.3 5.8 9. 9 8.0 3.84 35.5 5. 5..59. 5.5 9.9 9 8.9 4.00 4 38.80.5. 30.0 3.0.00. 0.5 4.34 0 9.0.4.0.5 5.85. 5.5 5.3 0.93 03 0.9.80.83 8..8.43.30 5.9.05 04. 8.30.94 9..3.5..35. 0 0.03 4. 3.34 5..35..4 0.8.90 08.08 5.8 3.8. 3..8.4 8.0.08 0 3.88 3.3 8 5.48 5.5 0.5 4. 8.5 3.5 3.09 34.33 4.4 5...0 4.44 9. 8 8.38 3. 4 3.38. 3.3 8.9.90 4.83 0.9 9.9 3.48 ENTERING AIR TEMP. = 80 0 F DB/ 0 F WB (@ HIGH SPEED) ( 0 F) 8 0 UNIT SIZE 40 0 F EWT TC SC GPM 45 0 F EWT TC SC GPM 0 F EWT TC SC GPM 0.0 0 0. 4.5 4.8 8.93 3.5.4.90.9 03 9.5.8 4.89.34 0.38 4.0 8 3. 4 9. 0 3.3 04 0.85.3 5..3.08 4.3 4 4.0 9.8 3.5 0 0 3.3.35 9.8 30. 9.45. 8 4.5.08. 08 4.43 5.0 0.3 34.0. 4 8.5.0 9.0.80 0 3. 38.9 5.9 4 5.8 3.8 3 3.04 4.43 8.5 0.3.09 40.4. 54.4 34.5 4 3.8 43.34 9.9 0.8 3 4 4.3 44. 8.5 9 0.4 38.0 5.0 4.3 3.83.9 0.09 9. 3. 3.49 8.5 0. 0 0.9 5.5. 9 03 8.3.5 3. 5.30 9.80 3.0.3 8..4 04 9.4.8 3.89.8 0.43 3. 4 3.0 5 9.. 0 34.33 0.8.8 8.39 8. 5. 8. 5.9 4.53 08 3.99 3..0 3. 0.. 5 5.03.80 5.00 0 5.99 35.04. 0 4.5 30.3 9.5 3.9.4.54 0.5 3.8. 5 49.0 3. 9.94 39.5. 5.85 4.89 40.44 3.3 8 54.5 34.8 0 0.9 4.95 30.9 8.59 0 5.34 9..5.8 8. 3. 4 0.4 9.. 5 03.3 0.0.89 4.4 9.3.40.00 8.4 9.0 0 04 8.35.5 3.0 5.3 9.95.55.3 9.0. 0 3. 9. 5.3.54.4 4.4.9 5.5 3. 08 35.35.0 5.89 9.3 9.09 4.8 9 4.5.34 4.04 0 53. 3. 8.9 43.98 8.3.3 3 3.5 5.53.0 5.4 34.3 9.3 45.9 9.. 5 3..9.9 4.5 3. 0..09 3.3 3 8.35 4.5 9. 5.8 ENTERING AIR TEMP. = 84 0 F DB/ 0 F WB (@ HIGH SPEED) ( 0 F) 8 0 UNIT 40 0 F EWT 45 0 F EWT 0 F EWT SIZE TC SC GPM TC SC GPM TC SC GPM 0 4.0.9.0.09. 5. 8. 0.3 4.55 03 8.0 5.0.00 4.44 3.45..0.0 5.5 04 30.00.9.. 4.4.53.4.9 4 5.0 0 54.4 4 9. 3. 4.0 5..5 40.0 4.88 0.0 08.4 33.08 5.3 5.83 9.0 3. 44. 5.4. 9 0 8. 3 49.0.9 0 8.08 44. 0 0.5 9.0 9 39.. 0.89 54. 5.4 8. 0 4.8..8 4.3 8.9 4 09.0 59. 0.30 9. 4 5. 4. 8 80.8 45. 0. 0.. 4.54 9.94 0.93 3.99.4 9.83 3.45 03.0 4. 5.4.9.9 4.58 9..43 3.94 04.94 5.3 5.59 4.3 8 3.55 4.8 0.93. 4.8 0 49.9.94 9.98 43.3 0 3.9 8. 3.99.38.40 08 55.80 30.9. 48.. 9.4 4.0 3.90 8.0 0 8.0 4.33. 4.04 40.9 4.8. 3.00.54 90.0 48.83 8.4.8 4.85 5.5 5. 3.8 3.5 4 00. 54. 8 0.4 8. 4.9..5 4. 4 4. 0..0 3. 9.0 0.49 3.8.4 9.45.4 03 4.8 3.49 4.4. 3.0 3. 8. 0.9 3. 04.43 4.3 4.40 3.0 5.88 3.84 9.. 3.9 0 4. 5.33.9 40..58. 34.9 0.5 5.8 08 5.94 8. 8. 44.9 4 5..49 38..49.3 0 9.5 4.95 3. 5 8.5 3.9.43 58. 33.8 9.9 83.4 4 45. 3.9.8 39.8 5.9 0. 8 35.43 0. 3 4 9. 49. 5.3 5 9.0 43. 9 3.8. 3 38.8. NOTE: For any other conditions, please use selection so ware for fan coil units. Apart from capacities, this so ware provides; a) Sensible heat ratio b) Leaving air temperature (DB/WB) - 0 F c) Leaving water temperature - 0 F d) Leaving water velocities (FPM) e) Water pressure drop (feet of water) LEGEND: TC - Total Capacity (MBH) SC - Sensible Heat Capacity (MBH) - Water Temperature Rise ( 0 F) EWT - Entering Water Temperature ( 0 F) GPM - Water flow (Gallons Per Minute) GE_ACWL_series.indd 3// : PM

CHILLED WATER COOLING CAPACITIES 3 ROW COIL (METRIC UNITS) ENTERING AIR TEMP. = 5 0 C DB/ 0 C WB (@ HIGH SPEED) ( 0 C) 5 UNIT 4 0 C EWT 0 C EWT 0 0 C EWT SIZE 0.5.89 0..93.4 0.09.3.3 0.0 03.8.4 0.3..85 0.0.5.5 0.0 04.99.8 0.4.9.98 0..0.0 0.08 0 5. 3.93 0.5 3.94 3.39 0.9.4.4 0.3 08 5. 4.3 0. 4.33 3. 0. 3.0 3.0 0.4 0 8.5.4 0.4.44 5.53 0.3 4.4 4.4 0. 8.9.8 0.43. 5.80 0.3 4.5 4.5 0. 4 9..38 0.4.3.30 0.35 5.04 5.04 0.4 0.4.8 0.0.89. 0.08.33.33 0.05 03.5.0 0..0.8 0.08.4.4 0.0 04.9.4 0..3.93 0.09.55.55 0.0 0 5.03 3.83 0.0 3.8 3.30 0.5.5.5 0. 08 5.54 4.5 0. 4.0 3. 0..90.90 0. 0 8.4.8 0.33.4 5.38 0.5 4.30 4.30 0. 8.0.5 0.34. 5.3 0. 4.4 4.4 0.8 4 9.3.4 0.3.0. 0.8 4.85 4.85 0.9 0.4.83 0.08.85.58 0.0.9.9 0.04 03.0.0 0.09.0.8 0.0.43.43 0.05 04.8.9 0.0..89 0.0.. 0.05 0 4.9 3.5 0. 3.3 3.3 0.3.5.5 0.09 08 5.39 4.5 0.8 4.08 3.5 0.4.9.9 0.0 0 8.0. 0..0 5.5 0. 4.5 4.5 0.4 8.3.4 0.9.30 5.49 0. 4.3 4.3 0.5 4 9.08.9 0.3.84 5.95 0.3 4. 4. 0. ENTERING AIR TEMP. = 0 C DB/9.5 0 C WB (@ HIGH SPEED) ( 0 C) 5 UNIT SIZE 4 0 C EWT 0 C EWT 0 0 C EWT 0 4.34. 0. 3.0.34 0..8 8.0 0. 4 03 4.85 3.00 0. 3 4.00. 3 0.9 3. 8.3 3 0. 5 04 5.4 3.9 0. 5 4.3.8 0 0.0 3.3 8.4 9 0. 0 9.0 5.0 0.4 3.43 4.8 8 0.35 5.8 5 4. 9 0. 8 08 0.04. 3 0.48 8. 5.4 0.3 9.4 8 4. 9 0.3 0 5.3 9.4 3 0. 3.44 8.3 0.59 9..0 8 0.4.05 9.90 0..99 8.5 0. 0. 3.43 0.48 4.8 0.88 0.84 4. 9.34 0.8.0 8.0 9 0.53 0 4.3.55 0. 3.4. 3 0.4. 8.0 0. 03 4.59.85 0. 8 3.8.5 0 0.5 3.. 9 0. 04 4.85 3.03 0. 9 4.0. 0. 3.3 0.4 4 0. 3 0 8. 5.8 0.3 4.95 4. 0.8 5. 9 4. 9 0. 3 08 9.34 5.84 0.3.9 5. 3 0.3. 4. 0. 5 0 4. 8.8 0 0.5..0 0.4 9.35.8 0.3 4.84 9. 0.5 9.0.9 0.48 9.. 0.3 9 4. 0.09 0.5 3. 8.9 0.5 0.4.8 4 0.4 0 3.95.44 0. 3 3.3. 0.. 3.9 8 0.0 9 03 4.38.3 0. 5 3.0.4 0.3 3.0 5. 5 0. 0 04 4.5.9 0. 3.93. 0.3 3. 3.4 0 0. 0 8.05 5.0 0..8 4.5 0.3 5.5 5 4. 0. 9 08 8.90 5.58 0.3 0.49 5.0 0.. 4.5 0. 0 3.00 8. 0 0.4 4..4 0.38 9.09. 0.3 3.9 8. 9 0.4.. 0.40 9.49.0 3 0.3 4 5.9 9.48 0.5. 8.44 0.43 0.3.4 0.35 ENTERING AIR TEMP. = 9 0 C DB/.5 0 C WB (@ HIGH SPEED) ( 0 C) 5 UNIT SIZE 4 0 C EWT 0 C EWT 0 0 C EWT 0 5.9 3. 0.8 5..9 0.4 4.3. 0. 03.5 3.9 0.3 5.5 3.30 0. 4.8.9 0.3 04.09 3.94 0.34. 3.5 0.9 5. 3. 0.5 0.5.0 0.0 0.8 4.0 0.5 9. 5.55 0.44 08 4..85 0..0.94 0.58 0.09.9 0.48 0..0.04 8.48 0.5 0.88 5.4 9.3 0.4.9. 5.09 9.4.0 0.93. 4 9.9 0. 4 5.4 4.0..45..0. 8 0.5 0.85 0 5.4 3. 0. 4.89.9 0.9 4..5 0. 03.3 3.5 0.5 5.45 3.5 0. 4..84 0.8 04. 3.5 0. 5.8 3.35 0.3 4.88 3.0 0.9 0.8.59 0.4 0. 5.8 0.40 8.55 5.5 0.34 08 3.5.34 0.5. 4.5 0.45 9.40 5.8 0.3 0 0.. 5 0.80.3 9.83 0.8 4. 9 8.3 0.5.0. 0.84.93 0.3 0. 4.9 9.5 0.59 4 3..9 0.93 9..3 0.9.3 0.0 0.5 0 5.4 3.0 0.8 4.9.9 0. 3.9.4 0.4 03.04 3.3 0. 5.0 3.0 0.8 4.40. 0.5 04.39 3.58 0. 5.49 3.0 0.9 4..9 0. 0.3. 0.38 9. 5.58 0.33 8.09 5.0 0.8 08.39.94 0.4 0.5. 0.3 8.94 5.58 0.3 0 8.8 0.5 0.4.0 9.8 0.55 3.3 8.5 0.4 9.4.0 0.. 9. 0.5 3.9 8 8. 0.48 4.9.0 9 0.4 8.38 0.3 0.3 5. 9.44 0.5 NOTE: For any other conditions, please use selection so ware for fan coil units. Apart from capacities, this so ware provides; a) Sensible heat ratio b) Leaving air temperature (DB/WB) - 0 C c) Leaving water temperature - 0 C d) Leaving water velocities (m/s) e) Water pressure drop (kp) LEGEND: TC - Total Capacity (kw) SC - Sensible Heat Capacity (kw) - Water Temperature Rise ( 0 C) EWT - Entering Water Temperature ( 0 C) LPS - Water flow (Liters Per Second) 8 GE_ACWL_series.indd 8 3// : PM

CHILLED WATER COOLING CAPACITIES 4 ROW COIL (METRIC UNITS) ENTERING AIR TEMP. = 5 0 C DB/ 0 C WB (@ HIGH SPEED) ( 0 C) 5 UNIT 4 0 C EWT 0 C EWT 0 0 C EWT SIZE 0.9.4 0.4.9.80 0.0.55.55 0.0 03 3.9.45 0..5.0 0... 0.08 04 3.48. 0...4 0.3.8.8 0.09 0.0 4.5 0.9 4.58 3.85 0. 3.0 3.0 0.5 08. 5.0 0.3 5.05 4.9 0.4 3.5 3.5 0. 0 0.0.48 0.48.53.3 0.3 5. 5. 0.5 0.49.8 0..8. 0.38 5.44 5.44 0. 4.48 8.55 0.55 8.5.0 0.4 5.9 5.9 0.8 0.80.0 0..5. 0.09.5.5 0.0 03 3.0.39 0.3.45.0 0.0.. 0.0 04 3.39.55 0.3.59.0 0.0.8.8 0.0 0 5.8 4.39 0.3 4.4 3. 0.8 3.0 3.0 0. 08.4 4.8 0. 4.90 4. 0.0 3.40 3.40 0.4 0 9.4. 0.38.9.4 0.9 5.04 5.04 0.0 0.0.55 0.40.0.43 0.30 5.5 5.5 0. 4 0.9 8. 0.44 8..98 0.33 5.9 5.9 0.3 0.5.03 0.09..5 0.0.48.48 0.05 03 3.3.35 0..39.0 0.08.. 0.0 04 3.3.5 0..53.5 0.09.. 0.0 0 5. 4.9 0.0 4.35 3.8 0.5 3.0 3.0 0.0 08.30 4. 0. 4. 4.08 0. 3.9 3.9 0. 0 9.3.03 0.3.09.00 0.4 4.89 4.89 0. 9.8.3 0.33.38. 0.5 5.08 5.08 0. 4 0.4 8.00 0.3 8.0.8 0. 5. 5. 0.9 ENTERING AIR TEMP. = 0 C DB/9.5 0 C WB (@ HIGH SPEED) ( 0 C) 5 UNIT SIZE 4 0 C EWT 0 C EWT 0 0 C EWT 0 5.0 3.0 0.4 4..4 0.0 3.35.3 0. 03 5.5 3. 0. 4.5 3.05 0.3 3.9.9 0.8 04. 3.4 0.9 5.04 3. 0.4 4.0.8 0.9 0 0.84.59 0.5 8.8 9 5. 0 0.4.0 4.9 0.3 4 08.0.3 0.58 9.8 3.3 5 0.4. 5.5 3 0.3 0 8.49.8 0.88 5.00 9.5 0..4 8. 0.5 9.4. 0.93 5. 0.04 0. 5. 5 8. 0.5 9 4.4.9.03.9.03 0.8 3 3.4 4 9.4 8 0. 4 0 4.9.90 0.9 3.98.53 0. 3.8. 0.3 03 5.4 3.34 0. 4..9 0.8 3..58 0.4 04 5.8 3.55 0.3 4.5 3.09 0.9 3.83. 0.5 0 0.. 0.4 8.3 5.3 8 0.3 3. 3 4. 4 0. 08.4.90 0.45 9. 4 5.9 0.3.3 3 5.3 0 0. 9 0.4 0.43 0.8 3.90 8.9 0.55 0.94.8 0.44.93 0.94 0. 4.5 9.38 0.58.44 8.0 0.4 4 9.3.0 0.9 5.9 0. 0. 3.4 9 8.9 3 0.5 0 0 4.0.9 0. 3.80.43 0.3 3.09.8 0. 03 5.0 3.9 0.8 4.30.80 0.5 3.54.54 0. 04 5.49 3.39 0.9 4.5.99 0. 3.5. 0.3 0 9. 5.9 0.33.9 5.5 0..4 4.5 0. 08 0.5.53 0.3 8. 4 5. 3 0.3 0. 3 5. 8 0. 4 0.0 9.84 0.55 3.0 8.4 8 0.4 5 0. 3. 3 0.3. 0.30 0.5 3. 8.90 0.4.0 8.00 0.38 4 8.39. 0.3 4.9 9.0 0.5.09 8.0 0.4 ENTERING AIR TEMP. = 9 0 C DB/.5 0 C WB (@ HIGH SPEED) ( 0 C) 5 UNIT SIZE 4 0 C EWT 0 C EWT 0 0 C EWT 0.8 3.3 0.33 5.9 3.30 0.8 5.04.94 0.4 03.90 4.34 0.38.8 3.84 0.33 5.8 3.43 0.8 04 8.43 4.4 0.40. 4.05 0.35.5 3. 0.9 0 5. 8.3 0..9.9 0. 0.90.45 0.5 08.03 9.35 0.8 4.5 0 8.8 0.9.3.3 0.58 0.43 4.4 4..3.49.0 8.5 9 0.9 0.89.9 5..33 3.55 3.8.3 9.5 3.49 0.93 4 3..0 0.49.4 4.59.5.5 9..03 0.5 3.5 0. 5.5 3. 0. 4.8.83 0.9 03.49 4.3 0.30.4 3. 0. 5.48 3.8 0. 04.9 4.40 0.3.8 3.9 0. 5.8 3. 0.3 0 4.8.80 0.5..8 0.48 0.3. 0.4 08 5.8 8. 0.3 3.5 0. 0.54.30.8 0.45 0 4.9 3.3 3 0.9 0..3 0.8. 3 0.3 0.9 5.55 4.0 3.0.. 0.8 8.0 4 0.5 0. 4 8.9 5.5.3 3.9 3.4 0.95 9.8 4.9 0.9 0. 3.44 0. 5.44 3.0 0.9 4..3 0. 03. 3.9 0.4.8 3.5 0. 5.3 3.5 0.8 04. 4. 0..55 3.5 0. 5.5 3.35 0.9 0 3.43.4 0.4.5.55 0.39 9.8 5.83 0.33 08 4.89 8.4 0.5..8 0.43 0.3.4 0.3 0.5.5 3 0.8 9.38 0.98 0.. 9.0 0.55 3.85 3. 5 0.8 0..5 0.9.8 0. 0.58 4.30 4.4 8 0.90.9.4 0. 8.4 9. 0.3 NOTE: For any other conditions, please use selection so ware for fan coil units. Apart from capacities, this so ware provides; a) Sensible heat ratio b) Leaving air temperature (DB/WB) - 0 C c) Leaving water temperature - 0 C d) Leaving water velocities (m/s) e) Water pressure drop (kp) LEGEND: TC - Total Capacity (kw) SC - Sensible Heat Capacity (kw) - Water Temperature Rise ( 0 C) EWT - Entering Water Temperature ( 0 C) LPS - Water flow (Liters Per Second) 9 GE_ACWL_series.indd 9 3// : PM

FAN PERFORMANCE DATA / 3 ROW COILS (ENGLISH UNITS) NUMBER BLOWER MOTOR SPEED CFM @ EXTERNAL STATIC PRESSURE (Inches of water) 0.0 0.05 0. 0.5 0. 0.5 0.3 0.4 0.5 HIGH 95 83 0 45 0 00 80 0 54 ACWL0 MEDIUM 53 40 3 05 88 0 55 4 5 LOW 5 5 05 93 80 5 - - HIGH 3 34 330 30 90 0 30 90 5 ACWL03 MEDIUM 340 35 30 85 0 35 0 - - LOW 30 9 84 40 5 90 - - HIGH 400 380 30 340 30 90 0 0 90 ACWL04 MEDIUM 3 34 330 30 90 0 3 0 90 - LOW 340 35 30 85 0 35 0 - - HIGH 33 00 558 55 438 30 80 ACWL0 MEDIUM 0 59 5 58 44 395 3 8 0 LOW 48 45 40 35 9 3 30 0 HIGH 8 39 00 49 598 5 4 40 390 ACWL08 MEDIUM 33 00 558 55 438 3 0 80 5 0 LOW 0 59 5 58 44 395 3 80 HIGH 080 045 00 95 90 88 83 580 ACWL0 MEDIUM 93 909 880 85 8 8 3 5 30 49 0 LOW 83 83 808 5 4 98 55 50 4 HIGH 5 8 080 040 000 94 89 8 0 ACWL MEDIUM 080 045 00 95 90 88 83 580 LOW 93 909 880 85 8 8 35 30 490 HIGH 0 09 0 030 000 98 ACWL4 MEDIUM 5 8 080 040 000 94 89 8 0 LO W 080 04 5 00 95 90 88 83 580 FAN PERFORMANCE DATA / 4 ROW COILS (ENGLISH UNITS) BLOWER MOTOR CFM @ EXTERNAL STATIC PRESSURE (Inches of water) NUMBER SPEED 0.0 0.05 0. 0.5 0. 0.5 0.3 0.4 0.5 HIGH 83 0 45 0 00 80 5 43 ACWL0 MEDIUM 53 40 3 05 88 0 3 3 9 LOW 5 05 93 80 5 5 - - HIGH 34 330 30 90 0 30 0 83 59 ACWL03 MEDIUM 35 30 85 0 35 0 0 5 - - LOW 9 84 40 5 90 95 - - HIGH 380 30 340 30 90 0 35 00 8 ACWL04 MEDIUM 34 330 30 90 0 30 0 9 5 - LOW 35 30 85 0 35 0 05 - - HIGH 33 00 558 55 438 30 30 5 0 ACWL0 MEDIUM 59 5 58 44 395 3 8 8 5 5 LOW 48 45 40 35 9 3 3 0 49 HIGH 39 00 49 598 5 4 43 405 85 ACWL08 MEDIUM 33 00 558 55 438 30 3 0 5 0 4 LOW 59 5 58 44 395 3 88 5 0 HIGH 045 00 95 90 88 83 9 5 ACWL0 MEDIUM 909 880 85 8 8 35 8 3 5 0 44 0 LOW 83 808 5 4 98 55 08 5 403 HIGH 8 080 040 000 94 89 835 94 535 ACWL MEDIUM 045 00 9 5 9 0 88 83 9 5 480 LOW 909 880 85 8 8 35 83 50 430 HIGH 0 09 0 030 05 984 9 ACWL4 MEDIUM 8 080 040 000 94 89 835 94 540 LOW 045 00 95 90 88 83 9 5 4 Note:. Values include losses for dry coil and filters.. Airflow values are in CFM. 0 GE_ACWL_series.indd 0 3// : PM

FAN PERFORMANCE DATA / 3 ROW COILS (METRIC UNITS) NUMBER BLOWER MOTOR SPEED LITERS PER SECOND @ EXTERNAL STATIC PRESSURE (Pascal) 0.0.5 5 3.5.5 5 00 5 HIGH 39 33 04 94 85 80 3 ACWL0 MEDIUM 9 3 05 9 88 80 3 8 LOW 0 0 9 9 85 8 - - HIGH 3 5 4 3 3 09 90 83 ACWL03 MEDIUM 0 53 4 35 3 99 - - LOW 4 40 34 4 3 0 90 - - HIGH 89 9 0 0 5 3 3 99 90 ACWL04 MEDIUM 3 5 4 3 3 09 9 0 - LOW 0 53 4 35 3 99 - - HIGH 34 99 83 3 43 0 0 3 8 ACWL0 MEDIUM 88 9 0 44 9 8 54 8 85 LOW 4 3 90 38 09 09 99 HIGH 3 349 330 30 8 4 0 98 84 ACWL08 MEDIUM 34 99 83 3 43 0 0 3 8 LOW 88 9 0 44 9 8 54 8 85 HIGH 493 4 455 434 44 395 340 4 ACWL0 MEDIUM 44 49 45 40 38 3 34 9 3 LOW 40 394 38 3 3 39 309 4 HIGH 54 58 49 4 44 4 3 88 ACWL MEDIUM 493 4 455 434 44 395 340 4 LOW 44 49 45 40 38 3 34 9 3 HIGH 590 59 548 53 55 48 4 45 ACWL4 MEDIUM 54 58 49 4 44 4 3 88 LOW 493 4 455 434 44 395 340 4 FAN PERFORMANCE DATA / 4 ROW COILS (METRIC UNITS) NUMBER BLOWER MOTOR SPEED LITERS PER SECOND @ EXTERNAL STATIC PRESSURE (Pascal) 0.0.5 5 3.5.5 5 00 5 HIGH 33 04 94 85 83 ACWL0 MEDIUM 9 3 05 9 8 8 8 0 LOW 0 9 9 85 8 35 - - HIGH 3 5 4 3 3 09 99 8 5 ACWL03 MEDIUM 53 4 35 3 99 - - LOW 40 34 4 3 0 90 45 - - HIGH 9 0 0 5 3 3 94 84 ACWL04 MEDIUM 3 5 4 3 3 09 99 45 - LOW 53 4 35 3 99 - - HIGH 99 83 3 43 0 0 5 5 95 ACWL0 MEDIUM 9 0 44 9 8 54 3 0 8 LOW 3 90 38 09 09 04 0 HIGH 349 330 30 8 4 0 00 9 35 ACWL08 MEDIUM 99 83 3 43 0 0 5 5 9 LOW 9 0 44 9 8 54 3 0 HIGH 493 4 455 434 44 395 3 30 4 ACWL0 MEDIUM 49 45 40 38 3 34 3 4 08 LOW 394 38 3 3 39 309 8 38 90 HIGH 58 49 4 44 4 394 38 53 ACWL MEDIUM 493 4 455 434 44 395 3 30 LOW 49 45 40 38 3 34 3 4 03 HIGH 59 548 53 55 48 49 44 430 ACWL4 MEDIUM 58 49 4 44 4 394 38 55 LOW 493 4 455 434 44 395 3 30 38 Note:. Values include losses for dry coil and filters.. Airflow values are in Liters per second. GE_ACWL_series.indd 3// : PM

SOUND POWER LEVEL (db re 0 - WATTS ) AT 0.5 ESP NUMBER BLOWER MOTOR SPEED OCTAVE BAND CENTER FREQUENCY - Hz 5 0 000 000 4000 8000 HIGH 58 53 49 4 45 40 33 ACWL0 MEDIUM 5 45 3 3 35 9 LOW 45 35 33 3 9 3 HIGH 0 55 48 4 4 35 ACWL03 MEDIUM 58 53 49 4 45 40 33 LOW 5 45 3 3 35 9 HIGH 3 5 54 49 43 3 ACWL04 MEDIUM 0 55 48 4 4 35 LOW 58 53 49 4 45 40 33 HIGH 8 5 53 54 49 4 ACWL0 MEDIUM 59 55 5 53 4 40 LOW 5 53 49 5 45 39 HIGH 9 3 0 5 5 5 45 ACWL08 MEDIUM 8 5 53 54 49 4 LOW 59 55 5 53 4 40 HIGH 0 8 5 4 0 54 ACWL0 MEDIUM 9 3 58 53 LOW 59 5 5 HIGH 9 5 4 5 ACWL MEDIUM 0 8 5 4 0 54 LOW 9 3 58 53 HIGH 3 58 ACWL4 MEDIUM 9 5 4 5 LOW 0 8 5 4 0 54 HOT WATER CAPACITIES NUMBER GPM (LPS) EWT - 0 F (5 0 C) CAPACITIES MBH (kw) GPM (LPS) EWT - 80 0 F (8 0 C) CAPACITIES MBH (kw) ACWL0 0.8 (0.043).9 (.0).05 (0.0) 0.5 (3.09) ACWL03 0. (0.04).3 (.3). (0.0).45 (3.35) ACWL04 0.5 (0.04).5 (.0).9 (0.05 ).9 (3.5 ) ACWL0.5 (0.0 ).3 (3.3).8 (0.3).4 (5.) ACWL08.3 (0.0).3 (3.0).0 (0.) 9.8 (5.8 ) ACWL0.83 (0.5) 8.3 (5.3) 3.0 (0.9) 8.9 (8.4) ACWL.9 (0.0 ) 9.0 (5.5) 3. (0.9 ) 30.4 (8.9 ) ACWL4.0 (0. ) 9.5 (5.) 3. (0.0) 3.5 (9.) NOTE: Capacities @ 0 0 F ( 0 C) Entering Air Temperature & 0 F ( 0 C) Water Temperature Drop and @high speed. LEGEND: EWT - Entering Water Temperature; MBH - 000 BTUH; GPM - Gallons Per Minute; LPS - Liters Per Second GE_ACWL_series.indd 3// : PM

DIMENSIONS / S: ACWL0 - ACWL4 A 09 (4.8) H D 4 J 5 (0.590) 3 B E 5 5 (.000) TOP VIEW 84 (.) END VIEW C G F FRONT VIEW LEGEND:. Blower & motor assembly. Cooling coil 3. Control box 4. Filter rack 5. Mounting holes. Drain pan. Duct connector DIMENSIONS A B C D E F G H J NO. OF MOTORS NO. OF BLOWERS ACWL0 (4.5) 59 (3.3) 54 (0) 59 (3.5) 8 (.3) 59 (0.8) (.93) (4.04 ) (8.33) ACWL03 (4.5) 59 (3.3) 54 (0) 59 (3.5) 8 (.3) 59 (0.8) (.93) (4.04 ) (8.33) ACWL04 (4.5) 59 (3.3) 54 (0) 59 (3.5) 8 (.3) 59 (0.8) (.93) (4.04 ) (8.33) ACWL0 09 (40.5) 59 (3.3) 54 (0) 99 (39.5) 8 (.3) 934 (3.8) (.93) 0 (40.04) (8.33) ACWL08 09 (40.5) 59 (3.3) 54 (0) 99 (39.5) 8 (.3) 934 (3.8) (.93) 0 (40.04) (8.33) ACWL0 359 (53.5) 5 (5.) 305 () 3 (5.5) 98 (.5) 5 (49.8) (8.93) 34 (53.04) (0.33) ACWL 359 (53.5) 5 (5.) 305 () 3 (5.5) 98 (.5) 5 (49.8) (8.93) 34 (53.04) (0.33) ACWL4 359 (53.5) 5 (5.) 305 () 3 (5.5) 98 (.5) 5 (49.8) (8.93) 34 (53.04) (0.33) NOTE: All dimensions are in mm (dimensions in brackets are in inches). 3 GE_ACWL_series.indd 3 3// : PM

DIMENSIONAL DATA / COIL CONNECTIONS CHILLED WATER COIL DIMENSIONS 3 ROW COIL 4 ROW COIL A B C A B C ACWL0 00 (3.9) 8 (4.3 ) 38 (.5) 90 (3.53) 8 (4.3 ) 5 (.5 ) ACWL03 00 (3.9) 8 (4.3 ) 38 (.5) 90 (3.53) 8 (4.3 ) 5 (.5 ) OUTLET ACWL04 00 (3.9) 8 (4.3 ) 38 (.5) 90 (3.53) 8 (4.3 ) 5 (.5 ) ACWL0 00 (3.9) 8 (4.3 ) 38 (.5) 90 (3.53) 8 (4.3 ) 5 (.5 ) C ACWL08 00 (3.9) 8 (4.3 ) 38 (.5) 90 (3.53) 8 (4.3 ) 5 (.5 ) ACWL0 00 (3.9 ) 43 (5. ) 38 (.5) 90 (3.53) 30 (5. ) 5 (.5 ) A 5 (.00") B INLET ACWL 00 (3.9 ) 43 (5. ) 38 (.5) 90 (3.53) 30 (5. ) 5 (.5 ) ACWL4 00 (3.9 ) 43 (5. ) 38 (.5) 90 (3.53) 30 (5. ) 5 (.5 ) NOTE: All dimensions are in mm (dimensions in brackets are in inches). HOT WATER COIL DIMENSIONS ACWL0 A 8 (.3) B 5 (.) C 4 (.3) D 90 (3.53) ACWL03 8 (.3) 5 (.) 4 (.3) 90 (3.53) ACWL04 8 (.3) 5 (.) 4 (.3) 90 (3.53) ACWL0 8 (.3) 5 (.) 4 (.3) 90 (3.53) OUTLET D B INLET 5 (.00") ACWL08 8 (.3) 5 (.) 4 (.3) 90 (3.53) ACWL0 9 (8.3) 5 (.) 4 (.3) 90 (3.53) ACWL 9 (8.3) 5 (.) 4 (.3) 90 (3.53) ACWL4 9 (8.3) 5 (.) 4 (.3) 90 (3.53) C A NOTE: All dimensions are in mm (dimensions in brackets are in inches). 4 GE_ACWL_series.indd 4 3// : PM

HEATER ARRANGEMENTS C HEATER BOX B SLIDING FRAME WITH HEATER A DIMENSIONS A B C ACWL 0/03/04 85 () 80 (. ) 3 (8.8 ) ACWL 0/08 939 (3) 80 (. ) 3 (8.8 ) ACWL 0//4 9 () 3 (9. ) (5.9) NOTE: All dimensions are in mm (dimensions in brackets are in inches). VALVE PACKAGES VALVE PACKAGE 3-D (for -pipe) Two gate shut off valves VALVE PACKAGE 4-D (for 4-pipe) Four gate shut off valves One balancing valv e Two balancing valves 3 One 3-way motor valv e 3 Two 3-way motor valves Two gate valves FCU 3 One balancing valv e CHILLER 3 One 3-way motor valv e 5 GE_ACWL_series.indd 5 3// : PM

TYPICAL SCHEMATIC WIRING DIAGRAM HEAT/COOL S - ELECTRIC HEATER TO FUSE DISCONNECT SWITCH HEATER OPTION LEGEND ATB AUXILIARY TERMINAL BLOCK HC TF TF 0HT HTR CA P C APACITO R EV ELECTRIC VALVE TG 0HT HTR FM FAN MOTO R TG GND LUG GROUND HC HEATER CONTACTOR GND L/L HVTB L/N HT R HVTB H EATER HIGH VOLTAGE TERMINAL BLOCK L/L LINE OR LINE L/N LINE OR NEUTRAL T'STAT N 0 ATB N 0 N 0 OHT _ O VER HEAT THERMOSTAT FIELD WIRING FACTORY WIRIN G Refer to table below for Speed Connections. SPEED WIRE COLOR ACWL 0 ACWL 03 ACWL 04 ACWL 0 ACWL 08 ACWL 0 ACWL ACWL 4 HI BLK MED-HI BLU MED RED LOW YEL LOWEST COM ORG WHT APPLICABLE FREQUENCY IN HERTZ NOTES:. Power supply, refer to unit nameplate.. Motors thermally protected. 3. HVTB is not required for heater models. 4. Use heater as per option required. If EV & heaters are factory installed, please read dashed line as continuous line. GE_ACWL_series.indd 3// : PM

TYPICAL SCHEMATIC WIRING DIAGRAM HEAT/COOL S - HOT WATER TO FUSE DISCONNECT SWITCH LEGEND ATB AUXILIARY TERMINAL BLOCK CA P C APACITOR EV ELECTRIC VALVE (COOLING ) GND L/L HVTB L/N EV E LECTRIC VALVE (HEATING ) FM FAN MOTO R GND LUG GROUND T'STAT N 0 ATB N 0 N 0 EV EV FM BRN CAP WHT COM HVTB HIGH VOLTAGE TERMINAL BLOCK L/L LINE OR LINE L/N LINE OR NEUTRAL _ FIELD WIRING FACTORY WIRIN G Refer to table below for Speed Connections. SPEED WIRE COLOR ACWL 0 ACWL 03 ACWL 04 ACWL 0 ACWL 08 ACWL 0 ACWL ACWL 4 FM SPEED CONNECTIONS HI MED-HI MED LOW LOWEST COM BLK BLU RED YEL ORG WHT APPLICABLE FREQUENCY IN HERTZ NOTES:. Power supply, refer to unit nameplate.. Motors thermally protected. 3. Use copper conductor wires only. 4. If EV & EV are factory installed, please read dashed line as continuous line. GE_ACWL_series.indd 3// : PM

INSTALLATION The complete shipment should be inspected for damage. Any damage, visible or concealed, should be reported immediately to the delivery man or driver and noted on the shipping invoice. Place unit in position and make sure that unit is level. This is important to assure proper drainage and operation. Slots provided in the mounting brackets should be used for installing the units. ELECTRICAL Please ensure power supply (V-Ph-Hz) to the unit is as per unit nameplate requirements. Caution: Operation of the unit on improper power supply will result in damage to the unit. Warning: Before installation or servicing, always TURN OFF all power to the unit. There may be more than one disconnect switch. Ensure all of them are turned off. GROUND & POWER WIRES Connect power wires as per wiring diagram. Connect ground wire to the ground lug inside the control box. MAINTENANCE COIL Coil may be cleaned by removing and brushing between fins with a stiff wire brush. Brushing should be followed by cleaning with vacuum cleaner. The coil may also be cleaned by using a high pressure air, if compressed air source is available. It should be pointed out that if air filters are used and periodically cleaned, the coils will not be clogged up prematurely. DRAIN PIPE Drain pipe should be checked before summer operation of unit. If it is clogged, steps should be taken to clear the debris so that condensate will flow out easily. A standard pipe cleaner for / ID pipe may be used. Periodic checks of the drain pipe should be taken during summer operation, as there is a possibility of it becoming clogged with dirt. FILTER CLEANING Remove access panel, slide filter out of filter rack, and clean as follows: Tap filter on solid surface to dislodge heavy particles. Wash under stream of hot water. If filter has been put to exceptional service, a mild solution of Sal-Soda, Tri-Sodium Phosphate or any other commercial solvent can be used. Set filter on end with slots in frame down, which allows it to drain. Filters should dry thoroughly before reuse. REPLACEMENT PARTS When writing for replacement parts, refer to model number and serial number on the nameplate of the unit. 8 GE_ACWL_series.indd 8 3// : PM

9 GE_ACWL_series.indd 9 3// : PM

Middle East Air Conditioners Co. Ltd. Middle East Air Conditioners Co. Ltd. P.O. Box 434 Dammam 344 KSA Kingdom of Saudi Arabia Tel: +9 3 84 88 Fax: +9 3 84 93 GE_ACWL_series.indd 0 3// : PM