BKF Control Panel Instruction Manual for the Owners

Similar documents
APP EOLE4. Applicable to program versions TAC5 Version DT & DG 2.7.0

ECL Apex 10. User Guide. ECL Apex 10 *087R9745* Installation and configuration. *vijem102*

ZoneTouch V2 Zone Control System Installation Manual

Optional Chip and Pin with Tap and Go

Product manual Oil Streak Sensor INTRODUCTION CONSTRUCTION. Master Sensor

Table of Contents. General Operation. 3 How Slam-A-Winner plays How the Wheel Scores How the Ball Lift works Programming Options...

ENGLISH SAFETY INSTRUCTIONS. Recommendations for safe operation. Operator safety. General warnings

Operations Manual. Automated Fuel Maintenance System FUEL TECHNOLOGIES INTERNATIONAL

CONTROL UNIT BIOS2. Manual for installation. Programmable Control board for wings gates.

Controller Specification Sheet

OPERATING MANUAL Digital Diesel Control Remote control panel for WhisperPower generator sets

WARRANTY...1 NOTICE INTRODUCTION USE...8

SPN 4364 (ACM)(EPA10); SPN 4364 (ACM)(GHG14) January Publication Number / Title Platform Section Title Change SPN 4364/FMI 18 - EPA10

Water Specialist CI Control Valve Programming and Cover Drawing Manual

AQUATIC INTELLIGENCE FILTER CONTROL GUIDE

Instruction of connection and programming of the VECTOR controller

ECONOMISER SERIES E2T USER MANUAL

Water Specialist PR Control Valve Programming and Cover Drawing Manual

Automatic Sliding Door Retrofit Drive Assembly. Installation Manual DoorControlsUSA.com

Lingenfelter NCC-002 Nitrous Control Center Quick Setup Guide

TECHNICAL MANUAL FOR ELECTRONIC SPEEDOMETER STR-RIEJU MATRIX 2

Stratomaster Smart Single

Caterpillar Electronic Technician 2012A v1.0 Product Status Report 9/23/2013 2:35 PM

MAGPOWR Spyder-Plus-S1 Tension Control

SRC. An Outdoor Reset Control for Sub-Atmosphere Steam Systems OUTDOOR TEMPERATURE

Installation Guide. ECL Comfort 210 / 310, application A231 / A Table of Contents

Digital Diesel Control Remote control panel for GENVERTER GV4 and GV7i

Configuring FDMS Nash-North (Datawire) for Credit Card / Debit Card Processing in Retail/Quick Service

MODEL 396/398 ELECTRON BEAM SOURCE ROTARY CRUCIBLE INDEXER

PRO series programmer

Service instructions. MAGNA Series 2000

Product Manual. Part Number: MVP-193 Mefi-6 ECU Revision: 1.0

Guangzhou Junliye Import&Export Co., Ltd. CW-6H Injector Diagnostic & Cleaning System. Operation manual

Setting up CoCard Credit Card / Debit Card Processing in Retail/Quick Service

Cafitesse Excellence Touch

Sliding Gate Operator User's Manual

QUICK TEST MODE:WITH POWER OFF - PRESS: Spin + Soil Level + POWER SERVICE MODE: Fast Track Troubleshooting. Bulletins:

ADJUSTABLE FREQUENCY CRANE CONTROLS

CONTENTS 1.0 INTRODUCTION SAFETY... 5

TROUBLESHOOTING TP. Index

USER MANUAL FOR AUTOMATIC A/C CHARGING STATIONS

Installation And Programming Manual of OPTIMA Eco Tec and OPTIMA Pro Tec OBD/CAN

Sliding Gate Operator User's Manual

One Solution You Can Trust!

Administrator edited the Terminal configuration 1014 Administrator printed the configuration. Enter the Administrative menu. Select DIAG.

TunnelWatch CARWASH TUNNEL CONTROL SYSTEM

Setting up Vantiv (fka Fifth Third) Tandem Credit Card / Debit Card Processing in Retail/Quick Service

Additions, Revisions, or Updates

Instruction of Solar Charge Controller. User s Manual

SPN 4364/FMI 17 - GHG17 SPN /FMI 16 - GHG17 SPN /FMI 14 - GHG17 SPN 3216/FMI 16 - GHG17 SPN 3216/FMI 18 - GHG17 SPN 3217/FMI 2 - GHG17

Tunnel Logic User s Guide. Copyright 2017 Auto Data Inc. Website:

The RCS-6V kit. Page of Contents. 1. This Book 1.1. Warning & safety What can I do with the RCS-kit? Tips 3

WIRELESS BLOCKAGE MONITOR OPERATOR S MANUAL

Quick Setup Guide for IntelliAg Model YP40 20 Air Pro

Installation and Operations Manual

Barrier Gate Manual. (DZX2.1 Control Board) (The third version) (Pictures for reference only, the product prevail in kind)

VOLUMETRIC BLENDING SYSTEM OPERATION MANUAL

Table of contents. Game Play. Game Set-up. Technical Description. Programming. Error Codes. Electronic Components. Game Specifications.

GREASE CONTROL GUNS GREASE CONTROL GUNS Grease control gun Grease control gun with rigid stem and 3 jaw connector ( ).

INDEX 1 Introduction 2- Software installation 3 Open the program 4 General - F2 5 Configuration - F3 6 - Calibration - F5 7 Model - F6 8 - Map - F7

Operation Panel(HMI)Instruction

COMMISSIONING Tick the tests carried out by attendee.

Additions, Revisions, or Updates

Certain Model Year Tacoma 2TR-FE Vehicles Exhaust Pipe Replacement for Catalytic Converter

Instruction of connection and programming of the OSCAR-N controller

User Instructions for WRC1021D. Doc

Nortoft Electronic A/S Sejrupvej 38 Sejrup DK-7323 Give Denmark

Inlet Controller TC5-ITA USER'S MANUAL. M rev. 02 K rev. 00

RADION Automatic sprayer control Software version 1.07

Show Name: Anaheim Home & Garden Show 2018 ELECTRICAL

PRODUCT REQUIREMENTS

NexSysLink. Operation Manual. NMEA 2000 SAE J1939 Indmar Engines. CAN Instruments Product Family

2004, 2008 Autosoft, Inc. All rights reserved.

The following rules and procedures are now in effect for the Downtown Parking Management Zone.

SmarTire TPMS Maintenance Hand Tool. Revision User Manual

Nissan R35 GTR 12 injector driver kit

Subject Underhood G System Error Codes and Symptoms System or Parts affected

Additions, Revisions, or Updates

MB A 12V/24V DC PROGRAMMABLE DUAL BATTERY ISOLATOR

Update Programming Transmission Control Module (TCM) for Improved Upshifting. Condition. Production

Gate & Door Controller with LCD and Intelligent Technology

3 Spin Klin Battery Operation and Maintenance Manual

HP21 SERVICE SUPPLEMENT UNIT INFORMATION. TSC6 Two-Speed Control

SmartPak Welding Controller WK-MPS-16 Constant Current

ERROR RECOVERY ERR R O C D O ES / REC V O E Y R PR C O EDURES E

Glow Plug for E Series Only

CADD -Solis VIP Ambulatory Infusion Pump Model 2120

To Purchase This Item, Visit BMI Gaming

EBIKE DIAGNOSIS FLOWS

Water Specialist EI Control Valve Programming and Cover Drawing Manual

SmarTire TPMS Maintenance Hand Tool. Revision User Manual

Water Specialist CK and EQ Control Valve Programming and Cover Drawing Manual

OPERATOR S MANUAL DYNAMIC TRIM CONTROL SYSTEM SERIES S

CADD-Solis Infusion Pump

RR4T USA - RS4T USA

Technical Information

RVD110 RVD G2381en. Installation. Commissioning

EXPERT 2V4SA. Temperature Controller. User s manual CLEAN MODE COMPENSATION HUMIDITY OUTSIDE TEMPERATURE

Wheel Products. WP8300 Operators Manual Rev: 910

MicroGuard 586 Retrofit Rated Capacity Indicator System. Calibration and Testing for:

Transcription:

1 Contents 2 Exploitation and maintenance... 2 2.1 Control Panel (CP)... 2 2.1.1 Panel Operation... 2 2.1.2 Start Page... 2 2.1.3 Stands... 3 2.1.4 Osmosis... 3 2.1.5 Diagnostics... 4 2.1.6 Engine speed... 6 BKF Control Panel Instruction Manual for the Owners 2.1.7 Setup... 6 2.1.8 Screen... 7 2.1.9 Fees... 7 2.1.10 Offers... 8 2.2 Upgrade... 8 Skarbimierzyce, 07 August 2012 Software version: 1.6.1 BKF CarWash CarWash Instruction Manual Module 2009 1

2 Exploitation and maintenance 2.1 Control Panel (CP) BkfCarWash washing module is controlled and navigated from the level of a liquid-crystal control touch-pad (Control Panel) which is situated on the doors of a switchboard. 2.1.1 Panel Operation BKF Control Panel is operated through a touch-pad. If a button or a field is to be pressed or changed, use your finger to press a field where a particular element is located. Do not use hard or sharp objects because it may result in a permanent and irredeemable damage of a display. 2.1.2 Start Page Menu 3. Service Technician level allowing for change of some factory settings available exclusively for an authorized service centre. From the Start Page level you can go to other pages such as: Stands Osmosis Diagnostics Rotations Setup General Information On many system pages you may select an appropriate stand. This activity is performed through context menu Stand Selection Picture 2.2 Stand selection BKF Control Panel Picture 2.1 start Page of BKF Control Panel System Start Page allows to view programs used at all stands. Control Panel is a system which can operate up to 8 stands. Passwords BKF Control Panel has got 3 access levels: 1. Guest default level allowing view of basic parameters of a car wash exclusively. No edition or reading of rotations option. 2. Administrator level allowing for the administration of a car wash, rotation readings and change of key settings. BKF CarWash CarWash Instruction Manual Module 2009 2

2.1.4 Osmosis 2.1.3 Stands Picture 2.4 Osmosis Control Page BKF Control Panel Picture 2.3 Stand Page BKF Control Panel Stand Page is for observation of key parameters of a stand work; users with access to administrator (or higher) level, may also count service impulses and control a car wash Menu Stand Status o Impulse the amount of money left till the end of wash o Ser + - a button for a service impulses count. It is available for users with access minimum to administrator level. Service impulses are counted on separate counters. o Stop stop button status. Green - pressed, red pressed; stand blocked. o NO - green pressure reducer works in normal mode o NC - green - pressure reducer works in bypass mode o Slow - green engine works in slow rotations o Fast - green - engine works in high rotations Menu Program Selection enables starting a program from Control Panel Level. Osmosis Page enables monitoring of osmosis parameters. Up float float position empty container Middle float float position empty container Supply Pressure pressure switch at osmosis inlet Pressure solenoid valve solenoid valve cutting off osmosis water supply Engine engine tell-tale Buttons RO1, RO2, RO3 osmosis selection 1 1 System supports max. 3 osmosis. BKF CarWash CarWash Instruction Manual Module 2009 3

2.1.5 Diagnostics Picture 2.5.2 The second Page of Diagnostics BKF Control Panel Picture 2.5.1 The First Page of Diagnostics BKF Control Panel The Page enables to check the status of particular activated elements of a car wash: Temperature the temperature of surroundings of a car wash Inside Temperature the temperature inside a car wash (option) Circulation 1 - green a circulation pump of equipment is on Osmosis Measurement 1 (2/3) - green an osmosis pump of equipment 1 (2/3) is on Float of Pr. 4 of equipment 1 (2/3) - green a float of level of osmotic water in equipment 1 (2/3). If an indicator is red, contact a service centre. Heating Pump 1 - green a floor heating pump 1 of equipment is on Dispenser gear 1 (2/3) shows current gear of a dispenser. Gear depends on the number of active stands Continue button the continuation to the next page of a car wash diagnostics The Page enables to check the status of particular activated elements of a car wash: Floor heating Button the transition to the setting page of floor heating system or ECO system (option) Rowafil Button the transition to the setting page of effluent treatment system (option) Engine protection 3f the status of phase cancellation protection Engine Lock (s) the notification of reaction time to phase cancellation or asymmetry Identify button identifies car wash stands Stand Information the transition to the page listing stands detected 4 BKF CarWash CarWash Instruction Manual Module 2009 4

Picture 2.6.3 The Page of the floor heating or ECO system operation The Page allows for floor heating system operation Equipment 1 - Master Button the transition to the setting page of floor heating or ECO system (option) for max. 8 car wash stands Equipment 2 - Slave 1 Button the transition to the setting page of floor heating or ECO system (option) for the next 3 car wash stands (if applicable) Equipment 3 - Slave 2 Button the transition to the setting page of floor heating or ECO system (option) for the next 3 car wash stands (if applicable) INIT/TUNE/PID/FAILURE/MAN - the description of system operation: INIT the status of data reading; TUNE - the status of regulation parameters setting; PID temperature adjustment; FAILURE regulation error; MAN manual operation of floor heating Red/green diode the visualization of operation status of a circulation pump for the floor heating along with the status of 0/1 control transmitter (off/on) Picture 2.7.4 The Page of the floor heating or ECO system operation - parameters The Page enables for parameter declaration of heating floor system Auto/Man Button the description of working mode of a floor heating system: Auto automatic work; Man manual work Error - (applies only to ECO system) the difference between set value of floor temperature and current floor temperature Floor 1/Floor 2- (applies only to ECO system) - temperature given by detectors set in a floor Set Temp. Set temperature value for supply water; set floor temperature value (for ECO system) Heating (%) the percentage rate of heating system use Pow. Pos. (%) the percentage value of the level of mixing valve opening Supply the value of supply water temperature Return - (applies only to ECO system) the value of return water temperature On temperature (Man) the temperature of surroundings when a heating system turns on Outside temperature current air temperature Heating Pump the status of pump operation Manual Position (%) the percentage level set for mixing valve opening From: /To: /Set heating to: - (applies only to ECO system) - the period of time when floor temperature can be changed (for example 10pm-6am the reduction of floor temperature) Setting Button go to the page of regulator tuning the page for a service technician 15min, 1h, 24h Buttons go to processes of water or floor temperature changes BKF CarWash CarWash Instruction Manual Module 2009 5

2.1.6 Engine speed 2.1.7 Setup Picture 2.8 The Page of Engine speed BKF Control Panel Engine Speed Page allows for reading the number of inserted payment units. Make sure which stand is active before quantity reading. This page is accessible for persons with administrator authorization minimum. Cash register it is an absolute register counting payment units (cash) Service it is a register of service units set from the side of a Stand Work time it is a register of work hours for each stand separately Coins / Notes / Key - these are registers which can be reset in any time by a person holding administrator authorization minimum. This register counts payment units between subsequent emptying of money cases. Reset inter-meter it is a button which resets coin, notes and keys inter-counter. Picture 2.9 The Setting Page of BKF Control Panel This Page allows for selected cars wash parameters setting and fro access to pages with further settings: Circulation Temperature- the temperature which activates circulation system. Changes are entered with pressing the field and entering new value on a numerical pad. Heating temperature - the temperature which activates floor heating. Changes are entered with pressing the field and entering new value on a numerical pad. Central Heating Temperature - the temperature which activates central heating inside a car wash. Changes are entered with pressing the field and entering new value on a numerical pad (only selected car washes). Powder dosing powder quantity dosed for work of one stand. The set value presents the time of dispenser work in 4second cycle. The following chart shows dosing values. Seconds of work grams 1 s 12 gr 1.5 s 18 gr 2 s 24 gr Date settings to set date, press, in turns, the fields of: day, month, year and enter appropriate values with the use of numerical pad. 6 BKF CarWash CarWash Instruction Manual Module 2009 6

Time settings to set time, press, in turns, the fields of: hour, minutes, seconds and enter appropriate values with the use of numerical pad. Start come back to Start Page Screen go to the Page of screen settings Internet go to the Page of the Internet settings Fees go to the Page of fees settings Offers - go to the Page of offer settings Password go to the Page of password changing 2.1.9 Fees If the date is not set correctly it may lead to faulty functioning of the offer functions. Make sure that the date is set correctly. 2.1.8 Screen Picture 2.11 The Page of fees setting of BKF Control Panel This Page allows for the change of fees for particular wash programs. Programs: Turbo (PrT) and Rims (PrF) are optional. Changes of fees are entered with pressing fees field and entering new value on a numerical pad. The fee unit equals to s/monetary unit therefore we set the amount of seconds sold to a customer for one monetary unit. Picture 2.10 The Page of screen settings of BKF Control Panel This Page allows for setting of basic screen functions. Commercial Mode / Free Mode the selection of work mode of equipment. When in Free Mode, the stands are active without the need to pay for a wash (this option is very useful during start-up offers of new car washes or in car showrooms). Start of time counters - the selection of a time when the impulse countdown starts. o Without delay the impulse countdown starts immediately after money is inserted. o With delay the impulse countdown starts after the program selection. Time Out - the time in seconds of automatic screen-saver. Change of authorization in case of switching it to on after the activation of screen-saver, the authorization is automatically changed to guest. This change is activated after the first touch. BKF CarWash CarWash Instruction Manual Module 2009 7

2.1.10 Offers Picture 2.14 Page no 2 of offer module of BKF Control Panel Offer module enables for the creation of promotion actions for each day separately in two time periods maximum. For a day selected, enter the hours when a promotion is valid and how many free seconds are added to each impulse (monetary unit). Picture 2.12 Page no 1 of offer module of BKF Control Panel Offer On button activates promotion action. In the field from, values from the scope of 0-23 may be entered, in the field to values from the scope 1-24. Moreover, it should be remembered that from value cannot be higher than to value. Two time periods enables the generation of offers, for example from 8pm to 8am the following day. Examples: To execute an offer from midnight to 8am, enter from 0 to 8. To execute an offer from 8pm to midnight, enter from 20 to 24. To execute an offer from 3pm to 8pm, enter from 15 to 20. To execute an offer from 8pm to 8am in week days, in the fields Mon. Fr. Enter from 0 to 8 and from 20 to 24. There is an option to copy values from the Monday day to all week days. This option is useful for offers which take place every day at the same hours. In such a case, particular parameters should be entered in Mon. day and then Copy from Mon. Button should be pressed. Picture 2.13 Page no 2 of offer module of BKF Control Panel Erase Button situated next to each week day allows resetting offer parameters for each day separately. Free Field: shows current (in particular time) number of seconds given to a customer for free to each impulse. 2.2 Upgrade The manufacturer of Control Panel issues periodically new versions of software. Contact a manufacturer s service center to obtain information on distribution rules of new software. BKF CarWash CarWash Instruction Manual Module 2009 8