INLINE Flow sensor for hazardous area II 1 G/D - II 2 D - II 3 GD - I M1

Similar documents
INSERTION flow sensor for continuous flow measurement

Positive displacement flowmeter for continuous flow measurement

Paddle-wheel flow controller for On/Off control

Paddle-wheel flow controller with optical principle for On/Off control

Paddle-wheel flow controller for On/Off control

Insertion magnetic inductive flowmeter

INSERTION flowmeter with paddle wheel, ELEMENT design

Positive displacement flowmeter

Type 2712 (8630) Continuous TopControl System. General data Compatibility Materials of wetted parts Body Rotor Shaft Seal

INLINE fitting with paddle-wheel for flow measurement

Positive displacement batch controller

Type 2511/12. Type Type 2030 Cable plug. ASI cable plug. Dosing control. General technical data Orifice Type 6518

INLINE sensor-fitting with paddle wheel for flow measurement

INLINE fitting with paddle-wheel for flow measurement

3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics

3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics

Inductive conductivity meter

Direct-acting 3/2 way plunger valve

display on the wall or in a panel away from the inline sensor SE30 for easy meter reading.

Pneumatic control unit for decentralized automation of ELEMENT process valves

Type S030. Operating Instructions. Symbols used. INLINE fitting. Bedienungsanleitung Manuel d'utilisation

Inductive conductivity meter

Intrinsically safe presure transmitters for hazardous environments Type MBS 4201, MBS 4251, MBS 4701 and MBS Technical brochure

Flap-Type Flow Meter Prall

Turbine flowmeters Series TM

Type Operating Instructions. Bedienungsanleitung Manuel utilisateur

Digital ph transmitter

Electrical position feedback for actuator sizes Ø mm

Level Measurement. Point level measurement Capacitance switches. Pointek CLS200 Standard. 4/18 Siemens FI Overview.

Level Measurement. Point level measurement Capacitance switches. Pointek CLS200 Standard. icenta Controls Ltd

Level Measurement Point level measurement - RF Capacitance switches

XMP ci. Process Pressure Transmitter with HART -communication. Ceramic Sensor. accuracy according to IEC 60770: 0.1 % FSO.

Inline Paddle Wheel Flow Switch

Metal tube variable area flowmeter for gases, liquids and steam

2/2-way Quarter-Turn Ball Valve in stainless steel with pneumatic rotary actuator, DN 10-50

Digital ph transmitter

PSF50 Paddle flow switch

DMK 331P. Industrial Pressure Transmitter. Pressure Ports With Flush Welded Stainless Steel Diaphragm

Oscillating piston flowmeters Series COVOL Positive displacement flowmeter for liquids

3/2-way Rocker Solenoid Valve for pneumatic systems

SATRON VT Pressure Transmitter

2/2-way Globe Valve for media up to +180 C, DN

Magnetic Paddle Flow Sensor/Switch for Easy On/Off Control

DMP 331P DMP 331P. Industrial Pressure Transmitter. Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm

Capacitive level sensors CLS 23

DMK 331P DMK 331P. Industrial Pressure Transmitter. Pressure Ports With Flush Welded Stainless Steel Diaphragm. Pressure Transmitter.

2/2 or 3/2 way direct acting rocker solenoid valve

BFS-10-O G1/4: BFS-10-O G1/2: BFS-10-O G1: Contact rating: BFS-10-O G1/4

General Specifications

SITRANS P measuring instruments for pressure

2/2 way Angle-Seat Valve for medium up to C, DN15-50

FLS F6.60 MAGMETER FLOW SENSOR INSERTION FLOW SENSORS APPLICATIONS MAIN FEATURES

3/2-way Small Solenoid Valve, G 1/8 - G 1/4 and sub-base

INSERTION fitting for flow measurement or analysis

Level instruments. Continuous level measurement - Capacitance transmitters SITRANS LC300. 5/262 Siemens FI Overview.

2/2- and 3/2-way Ball Valve with pneumatic rotary actuator, plastic body, DN 10-50

Direct-acting 2/2- or 3/2-way pivoted armature valve

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation

2/2-way Angle-Seat Valve for medium up to +180 C, threaded port connection, DN 15-65

Metal tube flowmeters. Series SC250. Metal Tube Flow Meters. Series SC250. Variable area flowmeter for liquids, gases and steam

3/2, 5/2, 5/2 bistable and 5/3 way pneumatic solenoid valve

2/2- and 3/2-way solenoid valve for aggressive fluids

SPOOL VALVES solenoid air operated 1/4 to 1/2 tapped body and NAMUR for integrated pilot

3/2-way Solenoid Valve, direct-acting, NC or NO

Flow switches Series AD/VH

FLOWX3 F3.20 High Pressure Paddlewheel Flow Sensor MAIN FEATURES APPLICATIONS OPERATING PRINCIPLE

Design and application

DMK 331P. Industrial Pressure Transmitter. Pressure Ports With Flush Welded Stainless Steel Diaphragm. accuracy according to IEC 60770: 0.

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation

Magnetic-inductive flow meter for hazardous areas

BRONZE ZEUS PNEUMATIC ANGLE-SEAT VALVE

Options guide. Electromagnetic flowmeters. M9xx

OM004, OM006 & OM008 Oval Gear Meter

Solenoid Valves Type 3963

USER s MANUAL 1. GENERAL INFORMATION 2. PRODUCT IDENTIFICATION

MX-SERIES OVAL GEAR FLOW METERS

DMP 331 DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor. Pressure Transmitter. Industrial

Ar-Mite TM Low Flow Armored Flowmeter

3/2-way and 2 x 3/2-way Solenoid Valve for pneumatics

MX06 - MX100 OVAL GEAR FLOWMETER SERIES APPROVED FOR USE IN HAZARDOUS AREAS

DMP 331P. Industrial Pressure Transmitter. Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm

2/2 or 3/2-way Solenoid Valve, with pivoted armature and isolating diaphragm

Electromagnetic flowmeters Series FLOMAT Insertion electromagnetic flowmeter for conductive liquids

Accessories for pneumatic stroke and rotary actuators CLASSIC and ELEMENT process valves

Point level measurement Capacitance switches

Volumeter TRZ 03-K PRODUCT INFORMATION. Reliable Measurements of Gas

BGN. All Metal Variable Area Flow Meter. Technical Data Sheet

2/2-way Diaphragm Valve with stainless steel design, weld end or clamp connection, DN 8-25

Magnetic float switch For vertical installation Model FLS (models with Ex approval: 60, AL-ADF)

DMP 333. Industrial Pressure Transmitter For High Pressure. Stainless Steel Sensor

Glass tube flowmeters Series 6000 Variable area flowmeter for liquids and gases

RMG Meßtechnik GmbH. Publication No E

2/2 Pressure operated valves

Angle-Seat Valve System for on/off control. Type 8801/2100 electro-pneumatically operated angle-seat valve + = TWO YEAR WARRANTY on this valve system

Level switches Series LC40 Float level switch for liquids

K - Flow Meter with Float

JUMO dtrans p20. Process pressure transmitter. Type Brief description. Key features. Block diagram

WBS 3000 Water Bottom Sensor for fuel oil and chemical storage tanks Installation and Operating Instructions

SATRON VVFe Pressure Transmitter

STAINLESS STEEL ARES PNEUMATIC ANGLE-SEAT VALVE

Transcription:

INLINE Flow sensor for hazardous area II G/D - II D - II GD - I M Type SE0 Ex can be combined with... Flow meter with NAMUR or NPN/PNP output signal Mounting, dismounting of electronics by a Quarter-Turn Protection- : approvals for use in Zone: 0,, - Gas (G) 0,, - Dust (D) M, M Type S00 INILINE fitting with PVDF paddle-wheel Type S070 Positive displacement flow fitting Type 805 Universal flow transmitter remote Type 86- on 60 PI flow controller on Solenoid valve Intrinsic safety barrier with NAMUR input PLC with NAMUR input The flow sensor SE0 Ex for continuous flow measurement is especially designed for use in neutral, slightly aggressive, solid-free liquids, in hazardous environments. The flow sensor SE0 Ex is made up of an electronic module and a measuring element, either a fitting S00 or a fitting S070, quickly and easily connected together by a Quarter- Turn. The sensor detects the paddle-wheel or oval gear rotation, modulates the current of the power supply line according to NAMUR standard or produces an NPN/PNP output signal (depends on model). To operate the NAMUR signal, an interface should be connected to the sensor SE0 Ex. The connection to an other device in the safe area depends on the used flowmeter model. General data Compatibility a) Materials Housing, cover Cable plug Materials wetted parts Fitting S00 a) Body Paddle-wheel Axis and bearings Seal Fitting S070 a) Body Rotor Shaft Seal Electrical connection Voltage supply cable Electrical data with fittings S00 or S070 (see corresp. datasheet) PC (NPN/PNP ); PPS (NAMUR ) glass fibre reinforced PA, with silicone gasket Fitting using restriction see SAFETY INSTRUCTIONS - NOTICE OF ATEX INSTRUCTIONS» Brass, Stainless steel, PVDF PVDF (only) Ceramics FKM Aluminium, Stainless steel PPS, Aluminium, Stainless steel Stainless steel FKM (EPDM or PTFE on request) Cable plug EN 750-80 (supplied) between 0.5 and.5 mm cross section; max. 50 m length, shielded Power supply b) Current consumption (with sensor) Output Reversed polarity (of DC) 8-5 VDC (NAMUR ) -6 VDC (NPN/PNP ) max. 7 ma (NAMUR vers.); 0 ma (NPN/PNP vers.) Depends on the device model and application area: - -wire current modulation according to Namur (50 Hz max.) - NPN/PNP (00 ma max., 50 Hz max.) Protected. Refer to the rubric SAFETY INSTRUCTIONS - NOTICE OF ATEX INSTRUCTIONS a) to choose the appropriate fitting for the area of application b) to choose the supply adapted to the area of application www.burkert.com p. /0

Complete device data (fitting + electronic module) Pipe diameter DN 6 to 00 (depends on the fitting model) Measuring range S00 fitting S070 fitting Medium temperature max. 80 C Fluid pressure max. S00 fitting S070 fitting Viscosity S00 fitting S070 fitting Accuracy Fitting S00 + sensor SE0Ex Teach-In (via remote transmitter 805) Standard K-factor Fitting S070 + sensor SE0Ex Linearity Repeatability S00 fitting S070 fitting 0. m/s to 0 m/s ; 0.5 l/min to 000 l/min to 00 l/min (viscosity >5 cps) to 66 l/min (viscosity <5 cps) PN0 (PVDF), PN6 (stainless steel, brass) PN55 (PN0 for flange ) 00 cps. max 000 cps. max (higher on request) ±0.5% of F.S.* (at 0 m/s) ±(0.5% of F.S. +.5% of Reading)* ±0.5% of Reading ±0.5% of F.S.* (at 0 m/s) 0.4% of Reading* 0.% of Reading* Environment Ambient temperature Relative humidity Standards and approvals Protection class Standards ATEX EMC -5 C up to + 60 C (operating and storage) 80%, non condensated IP67 with connector plugged-in and tightened acc. to EN 6059 EN 5004 (997) EN 5000 (00) EN 500 EN 508-- (998) EN 6000-6- (00) EN 6000-6- (00) NAMUR EN 60947-5-6 * Under reference conditions i.e. measuring fluid=water, ambient and water temperatures=0 C, applying the minimum inlet and outlet pipe straights, matched inside pipe dimensions. F.S.=Full scale (0 m/s) Accuracy diagram Max. error [%] 0 8 6 4 0.5% 0.5% o.f.s. +.5 o.f.s. % o.r. F.S. = Full scale o.r. = of Reading - 4 5 6 7 8 9 0-4 -6-8 -0 Bürkert Typical curve Standard calibration Teach-In calibration Flow velocity [m/s] p. /0

SE0 Ex Installation into S00 fitting The flow sensor SE0 Ex can easily be installed into any Bürkert INLINE fitting system S00 with integrated PVDF paddle-wheel. The minimum straight upstream and downstream distances must be observed. According to pipe s design, necessary distances can be bigger or a flow conditioner can be used to obtain the best accuracy. For more information, please refer to EN ISO 567-. EN ISO 567- prescribes the straight inlet and outlet distances that must be complied with when installing fittings in pipe lines in order to achieve calm flow conditions. The most important layouts that could lead to turbulence in the flow are shown on the left, together with the associated prescribed minimum inlet and outlet distances. These ensure calm, problem-free measurement conditions at the measurement point. DN = orifice Fluid direction --> Regulating valve x 90 elbow joint Extension 50 x DN 5 x DN 5 x DN 5 x DN 8 x DN 5 x DN x 90 elbow joint dimensional 40 x DN 5 x DN 90 elbow joint or T-piece 0 x DN 5 x DN Reduction 5 x DN 5 x DN The flow rate sensor can be installed into either horizontal or vertical pipes. Selection of fitting / pipe size Correct Incorrect Example: - Specification of nominal flow: 0 m /h - Ideal flow velocity:... m/s - For these specifications, the diagram indicates a pipe size of DN40 Correct Correct Correct Incorrect Incorrect Pressure and temperature ratings must be respected according to the selected fitting material. The suitable pipe size is selected using the diagram Flow / Velocity / DN. The sensor is not designed for gas flow measurement. Incorrect Flow rate gpm 000 000 500 00 00 50 0 0 0.5 0. 0. 0.05 l/min 5000 000 500 00 50 0 0 5 0.5 0. 0. m/h 500 00 00 50 0 0 5 0.5 0. 0. 0.05 0.0 DN 65 DN 50 DN 40 DN DN 5 DN 0 DN 5 DN 08 DN 06 0.0 0. 0. 0. 0.5 5 0m/s Flow velocity 0. 0.5 5 0 0 0fps p. /0

Installation into S070 fitting The fitting can handle particle sizes up to 50 μm. To prevent damage or locking from dirt or foreign matter, we strongly recommend the installation of a 50 μm (60 mesh) strainer as close as possible to the inlet side of the sensor. The pipe must be filled with liquid and free from air bubbles. Avoid air purge of the system. Ensure the fitting is installed so that the rotor shafts are always in an horizontal plane. Flow direction is marked by an arrow on the body. Correct installation Incorrect installation Design The flow sensor consists of an electronic module SE0 Ex associated to a fitting S00 or S070 respectively with integrated measurement paddlewheel or oval gear. This connection is made by means of a Quarter-Turn. When liquid flows through the pipe, the fitting paddle-wheel or oval gear is set in rotation modulating the current of the power supply line according to NAMUR standard. The modulated frequency of this signal is proportional to the flow. This signal is converted, by the connected type NAMUR barrier, into a frequency signal on its open collector output. The electrical connection of the sensor is made via a cable plug EN 750-80 (Type 508). Quarter-Turn Technology Electronics SE0 Ex Fitting S00 Fitting S070 p. 4/0

Overview of hazardous areas depending on SE0 Ex flow sensor models (according to ATEX) Equipment for explosive atmospheres (surfaces) - GROUP II This equipment can be installed in some potentially explosive atmospheres (surface industries or mining depending on the model) and is in compliance with the 94/9/CE directives. Very high level of protection High level of protection Normal level of protection Gas Zone 0 atmospheres present continuously, long periods or frequently Dust Zone 0 atmospheres present continuously, long periods or frequently Gas Zone atmospheres are likely to occur Dust Zone atmospheres are likely to occur Gas Zone atmospheres are unlikely to occur or present only infrequently and for a short period only Dust Zone atmospheres are unlikely to occur or present only infrequently and for a short period only CATEGORY SE0 Ex - Namur II G/D (Item no. 55 90) EEx ia IIC T6 - IP6X T80 C associated with PVDF, brass, stainless steel or aluminium fittings CATEGORY SE0 Ex - Namur II D (Item no. 55 454) Not to be used Not to be used Not to be used Not to be used IP6X T80 C associated with PVDF, brass, stainless steel or aluminium fittings or an 8-5 V supply source or an 8-5 V supply source CATEGORY SE0 Ex - II GD - NPN/PNP (Item no. 55 5) EEx na II T4 - IP6X T5 C associated with PVDF, brass, stainless steel or aluminium fittings Not to be used Not to be used Not to be used Not to be used a -6 V supply source a -6 V supply source Equipment for explosive atmospheres (Firedamp mines) - GROUP I CATEGORY SE0 Ex - Namur I M (Item no. 55 455) EEx ia T80 C only associated with brass or stainless steel fittings Firedamp mines zone M Very high level of protection interface with and with a mechanical protection cover Firedamp mines zone M High level of protection interface with and with a mechanical protection cover Note * The open circuit voltage for the NAMUR input must be included between 8 and 5 V. p. 5/0

Safety orders - Notice of ATEX instructions The appropriate SE0 Ex model is function of the installation environment. Model SE0 Ex Namur (Item no. 55 90) Group II - Category for potentially explosive zones of gas (0, and ) and dust (0, and ) ATEX marking meaning and ATEX installation zones CE 00 II G/D EEx ia IIC T6 -IP6X T80 C ambient T: -5 C Ta 60 C LCIE 04 ATEX 6070 X Special conditions for a safe use The device is an certified material according to EN 5000. It may be installed in potentially explosive atmospheres: zones 0, or and zones 0, or. The connector can only be connected to certified equipment. This combination must be compatible with rules (see electrical safety data in the table under the connection diagram opposite). The ambient temperature of use must always be between these limits: from -5 C to +60 C. Compatible mechanical assembly and fluid connections: Use PVDF, brass, stainless steel or aluminium fitting only. Any other connection is prohibited. Hazardous area L- Electrical safety data Ui (V) 5 V li (ma) 50 ma Pi (mw) 88 mw Ci. nf Li 0 Plug EN 750-80 of the SE0 Ex L+ PE Safe area - + Intrinsic safety barrier NAMUR ) 8-5 V Earth the shielding of the cable on side of the measuring exploitation ) Use an appropriate power supply which complies with the following electrical specifications Model SE0 Ex Namur (Item no. 55 454) Group II - Category for potentially explosive zones of dust ( and ) ATEX marking meaning and ATEX installation zones CE 00 II D IP6X T80 C ambient T: -5 C Ta 60 C LCIE 04 ATEX 6070 X Hazardous area PE Safe area 0 VDC V+ (8-5 VDC) Special conditions for a safe use The device is an certified material according to EN 508--. It may be installed in potentially explosive atmospheres: zones or. The connector may be connected to an 8-5 V supply source. It is preferable to use an appliance that has the certification (NAMUR type). The ambient temperature of use must always be between these limits: from -5 C to +60 C. Plug EN 750-80 of the SE0 Ex ma I = 0.5/.5 ma or any appliance able to detect the current modulation according to NAMUR standard Compatible mechanical assembly and fluid connections: Use PVDF, brass, stainless steel or aluminium fitting only. Any other connection is prohibited. p. 6/0

Safety orders - Notice of ATEX instructions Model SE0 Ex Namur (Item no. 55 455) Group I - Category for firedamp mines M ATEX marking meaning and ATEX installation zones CE 00 I M EEx ia T80 C ambient T: -5 C Ta 60 C LCIE 04 ATEX 6070 X Special conditions for a safe use The device is an certified material for firedamp mines according to EN 5000. It may be installed in potentially explosive atmospheres: zone M. The connector can only be connected to certified equipment. This combination must be compatible with rules (see electrical safety data in the table under the connection diagram opposite). The ambient temperature of use must always be between these limits: from -5 C to +60 C. Hazardous area L- Plug EN 750-80 of the SE0 Ex L+ PE Safe area - + Intrinsic safety barrier NAMUR ) 8-5 V Earth the shielding of the cable on side of the measuring exploitation ) Use an appropriate power suplly wich complies with the following electrical specifications Compatible mechanical assembly and fluid connections: Use brass or stainless steel fitting only. Any other connection is prohibited. The appliance must be protected from a mechanical damage. Mechanical protection with order code 55 59 must be used. This protection is mounted on the sensor by using an appropriate bracket (not included in our delivery). Electrical safety data Ui (V) 5 V li (ma) 50 ma Pi (mw) 88 mw Ci. nf Li 0 Model SE0 Ex NPN/PNP (Item no. 55 5) Group II - Category for potentially explosive zones of gas () and dust () ATEX marking meaning and ATEX installation zones CE 00 II GD EEx na II T4 -IP6X T5 C ambient T: -5 C Ta 60 C INERIS 04 ATEX 05X Special conditions for a safe use Hazardous area Plug NPN wiring EN 750-80 of the SE0 Ex L+ L- Safe area V+(-6 V) GND The device is an ATEX certified material according to EN 500 and EN 508--. It may be installed in potentially explosive atmospheres: zones or. 4 Pulse output NPN PE The connector may be connected to a -6 V supply source. The ambient temperature of use must always be between these limits: from -5 C to +60 C. Compatible mechanical assembly and fluid connections: PVDF, brass, stainless steel, aluminium fittings can be used. Any other connection is prohibited. L- PNP wiring L+ 4 Plug EN 750-80 of the SE0 Ex Pulse output PNP PE V+(-6 V) GND Electrical safety data on power supply line (L+/L-) U max. 6 V I max. 0 ma P max. 08 mw p. 7/0

Dimensions [mm] Electronics SE0 Ex Mounted on S00 fitting Mounted on S070 fitting 54 44 9 40 66 H DN H 06 95.5 08 95.5 5 00.5 0 98.0 5 98.0 0.0 40 05.5 50.0 H Orifice H 5* 0 5 6 40 50 5 80 9 00 9 * Only with threaded connection 65.0 Ordering chart - sensor Type SE0 Ex for fitting S00 or S070 (to be ordered separately) Specifications Voltage supply Output Electrical connection Item no. SE0 Ex - Namur II G/D for explosive gas and dust environments: zones 0, or and 0, or SE0 Ex - Namur II D for explosive dust environments: zones or SE0 Ex - II GD for explosive gas and dust environments: zones or SE0 Ex - Namur I M for fiery mines 8-5 VDC - via an barrier with NAMUR input* 8-5 VDC or via a NAMUR input* Namur current modulation - wires Namur current modulation - wires -6 VDC NPN / PNP 8-5 VDC - via an barrier with NAMUR input* * The open circuit voltage for the NAMUR input must be included between 8 and 5 V. Namur current modulation - wires cable plug EN 750-80 cable plug EN 750-80 cable plug EN 750-80 cable plug EN 750-80 55 90 55 454 55 5 55 455 Ordering chart - spare parts for sensor Type SE0 Ex (to be ordered separately) Specifications Item no. Cable plug EN 750-80 (Type 508) with blue cable gland and silicone gasket 67 56 Mechanical protection in stainless steel for mining application (80 x 80 x 80) 55 59 p. 8/0

Safety barrier or 4 channels, digital inputs: proximity detectors NAMUR, contacts... Rail mount on hat profile 5 mm All connections by removable screw terminals Specifications Digital inputs Intrinsic safety inputs Non recopy outputs Collector cut-off power: Selection of the sensor type Selection of the logic Each of the 4 x inputs can be configured independently for a contact or a proximity detector NAMUR as per DIN 94. Proximity detector NAMUR as per DIN 94 or free potential contacts, relays, pressure or temperature switches or push buttons in hazardous area. According to the type of sensor and the chosen logic: a green LED on the front panel displays a free-potential contact for each channel without common wire. 5 V - 60 ma - 0.9 VA - 50 Hz Inductive / capacitive certified NAMUR proximity detector or free-potential contacts. By a mini-dip choice of the active output in presence or lack of target (proximity detector) or when contact is NO (Normally Open) or NC (Normally Closed). Fault detector For all inputs configured as NAMUR, all models are provided with fault detector (broken line or short-circuit). In faulty case, the green front LED switches off, the contact of the defective channel opens and the red LED corresponding to the defective channel switches on. Other channels are not affected. Power supply 4 V DC ±0% 0 V AC ±0% front panel yellow LED is ON when supply is active Consumption 5 VA Specifications (continued) Connections All connections by removable screw terminals. Supply distribution by means of a flat cable from one unit to the next one. Classification for explosive areas Ambient Temperature Operating Storage Dimensional and mechanical Installations conditions Mounting on DIN rail: Mounting inside a cabinet: Intrinsic safety associated apparatus. It must be installed in safe area and connected to materials installed in zone 0, or - Gas (G) or in zone 0, or - Dust (D) Classification according to ATEX 94/9/CE : I/II (M)/() G/D [EEx ia] IIC Safety parameters see EC-type certificate LCIE 00ATEX 604X -0 C to +60 C -0 C to +50 C (recommended) -40 C to +80 C Housing for symmetric DIN rail (hat profile 5mm as per standard NFC605 / EN500) - Depth :0 mm ; Width on rail 9.5 mm ; - Height : 90 mm - 45 mm overall including space for cables. Minimal distance between rails : 80 mm. must take into account thermal dissipation and risk of overheating generated by housings installed side by side. In case of a high concentration inherent safety barrier, we recommend to leave a free space of 0 mm between each group of 8 units (horizontal rail) and between each group of 4 units (vertical rail). It is recommended to close the electrical cabinet and to ensure a circulation of fresh air even by means of an air conditioner to keep the inside temperature at the level compatible with the recommended operating temperature among the units. Ordering chart barrier Classifications for explosive areas Voltage supply Output Number of channels Item no. 4 VDC open collector, 5V, 60 ma, with Namur input 55 456 ATEX 94/9/CE open collector, 5V, 60 ma 4, with Namur input 55 457 I/II (M)/() G/D [EEx ia] IIC 0 VAC open collector, 5V, 60 ma, with Namur input 55 458 open collector, 5V, 60 ma 4, with Namur input 55 459 p. 9/0

Interconnection possibilities with the sensor Type 800 SE0 Ex with marking II G/D and I M Potentially Zone Electronics + S00 Intrinsic safety Namur input Type 805 - Batch transmitter or panel-mounted Type 80 - Flow transmitter Electronics + S070 PLC Type 805 - Universal transmitter or panel-mounted SE0 Ex with marking II D Potentially Zone Electronics + S00 Type 805 - Batch transmitter or panel-mounted Type 80 - Flow transmitter Electronics + S070 Interface with NAMUR input Type 805 - Universal transmitter or panel-mounted PLC with NAMUR input SE0 Ex with marking II GD Potentially Zone Electronics + S00 Type 805 - Batch transmitter or panel-mounted Type 80 - Flow transmitter Electronics + S070 PLC Type 805 - Universal transmitter or panel-mounted To find your nearest Bürkert facility, click on the orange box www.burkert.com In case of special application conditions, please consult for advice. We reserve the right to make technical changes without notice. 0606/_EU-en_008999 p. 0/0