Centrifugal Pumps (Part Nos. PS2SS PS73SS) PS2SS

Similar documents
INSTALLATION AND SERVICE MANUAL

INSTALLATION AND SERVICE MANUAL

8000 / 10,000 / 12,000

Cascade Owners Manual

Artesian Owners Manual

SUNC1200 / ITEM #40882 SUBMERSIBLE UTILITY PUMP OPERATIONS MANUAL

Cascade Owners Manual

OWNER S MANUAL EVOLUTION 3500, 4500, 5500, & 8500 SERIES PUMPS

Artesian2 Owners Manual

OWNER S MANUAL. 6. If you aren t competent to instal the pump, get help from a qualified source.

OWNER S MANUAL SUBMERSIBLE UTILITY PUMP

KP-C Series. Close Coupled End Suction Centrifugal Pumps. Installation, Operation and Maintenance

ArtesianPro Owners Manual

Artesian2 Owners Manual

VADA - V60-J PRODUCT OVERVIEW CONSTRUCTION MOTOR USAGE LIMITATIONS WARRANTY

Installation and Service Manual for RV33, RV332, RV75, RV752, RV100, RV1002

Owner s Manual Drill and Light Weight Portable Utility Pumps

UNPACKING SAFETY GUIDELINES GENERAL SAFETY INFORMATION. Operating Instructions & Maintenance Manual

INSTALLATION & OPERATING INSTRUCTIONS

ESE Series Cast Iron Sewage Pumps

Model and Series 115 VAC INDUSTRIAL DIAPHRAGM PUMPS. PumpAgents.com - buy pumps and parts online INDUSTRIAL DIAPHRAGM PUMPS

SUNC3000 / Item #40885

End Suction Centrifugal

Voltmaster Centrifugal Trash Pumps

OWNER S MANUAL SELF-PRIMING PORTABLE UTILITY PUMP

VADA - V75-S PRODUCT OVERVIEW CONSTRUCTION USAGE LIMITATIONS MOTOR WARRANTY

SERVICE MANUAL 200 SERIES MOTORIZED 20352, 20452, 20551, 20552, AND MODELS

HALLMARK INDUSTRIES INC

Submersible Effluent Pump

Wilo SP Series Submersible Utility Pumps ETT. ETT Installation and operating instructions

barmesapumps.com CD SERIES RPM Installation, Operation & Maintenance Manual End-Suction Centrifugal Stainless Steel Pumps

END SUCTION CENTRIFUGAL PUMPS

IMPORTANT SAFETY INSTRUCTIONS

LAWN SPRINKLER, IRRIGATION PUMP

MODEL P INSTALLATION INSTRUCTIONS

BOILER FEED SYSTEM OPERATION AND MAINTENANCE MANUAL

Installation & Operating Manual

3 FT CORD Models , , , FT CORD W/GFCI Models , , ,

M-3025CB-AV Fuel Pump

Material required for drilled well application (indoor use only)

Installation and Service Manual for SRC25, SRC252, SRC50, SRC502, SRC75, SRC752

Pumps and Maintenance

Self-Priming Centrifugal Pumps

Matala. VersiFlow Series. Instruction and Maintenance Manual

END SUCTION CENTRIFUGAL PUMPS

barmesapumps.com IB SERIES & 3500 RPM Installation, Operation & Maintenance Manual End Suction Centrifugal Pumps

barmesapumps.com BP33 & BP & RPM Installation, Operation & Maintenance Manual Submersible Sump / Utility Pumps

GARDEN HOSE UTILITY PUMP

Submersible Sewage Ejector Pump

PUMP PRIMING INSTALLATION CHECK MOTOR ROTATION PUMP START-UP MOTOR REPLACEMENT DISASSEMBLY ELECTRICAL HOOKUP ASSEMBLY

3 FT CORD UL/NEC Models , , , FT CORD w/gfci UL Models , , ,

Owners Manual: - Pumps

SERVICE MANUAL 200 SERIES MOTORIZED 20352, 20452, 20551, 20552, AND MODELS

3" & 4" Cast Iron Self-Priming Centrifugal Pump Instruction Manual

L-SERIES PUMPS. Operating Manual. Includes Pumps: L-305 L PONDS

INSTALLATION INSTRUCTIONS

OWNER S MANUAL Series: PFSPPPP33 1/3 HP 3450 RPM 60 Hz Series: PFSPCPC50 1/2 HP 3450 RPM 60 Hz Submersible Sump Pumps

Professional Séries. Professional Séries. Model T03828 SUBMERSIBLE SUMP DUPLEX SYSTEM SUBMERSIBLE SUMP DUPLEX SYSTEM. 1/3HP 2400 GPH Head of 20 (6 m)

MODEL SS INSTALLATION INSTRUCTIONS

CARTRIDGE FILTER SYSTEMS OWNER S MANUAL

Series: PFUEG 1/12HP, 5000 RPM, 60 Hz Utility Pumps

300 SERIES 331, 332, 333, 344, 356 AND 367 MODELS

Operation and Maintenance. S100 Series Centrifugal Fire Pumps. Table of Contents. Visit us at F /22/02 6/21/18

Aqua Ultraviolet Sunami Series Pumps 1/3HP, 3/4HP, 3HP, 4HP, 5HP

Noryl Series and Polypropylene Series

INSTALLATION INSTRUCTIONS

LIQUIDYNAMICS Light Viscosity Bulk Transfer Cart

Model: PFUPPP M10. 1/4 HP 3450 RPM 60 Hz Submersible Utility Pump OWNER S MANUAL. Power-Flo Pumps & Systems PUMPS

VERTICAL MULTI-STAGE CENTRIFUGAL PUMPS

SUBMERSIBLE PUMP HSE RANGE

Operating and Maintenance Manual Gas/Diesel Engine Powered Self-Priming Centrifugal Pumps Series

MH Series - Horizontal Multistage Pump OWNER'S MANUAL

200 SERIES 20302, 20402, 20501, 20502, 22001, 22002, 23201, AND MODELS

PRESSURE BOOSTER 150

Operating Manual for Rotary Gear Pumps CMI, S.A. (Mendaro, Guipuzkoa, Spain)

OWNER S MANUAL D.E. CARTRIDGE. Installation Operation Parts. Models PCDE-30 PCDE-40

ArtesianPro Owners Manual

VERTICAL MULTI-STAGES CENTRIFUGAL PUMPS

Pump Installation & Service Manual

GeyserMax-Flow Series

SELF PRIMING CHEMICAL SERVICE PUMPS

50830 Series Low Pressure Centrifugal Pump

UNPACKING SAFETY GUIDELINES GENERAL SAFETY INFORMATION. Operating Instructions & Maintenance Manual

StormPro BA Series Sump Pump

Self-Priming Close-Coupled Centrifugal Pumps In 316 Stainless Steel, Bronze and Cast Iron

SHALLOW WELL JET PUMP

Installation, Operation & Parts Manual BV40 Submersible Sewage Ejector Pump

FP0S2300X FP0S3000X. Submersible Waterfall/Utility Pumps OWNER S MANUAL. Call Installation/Operation/Parts. English...

PROMAG SR SERIES SEAL-LESS CENTRIFUGAL PUMPS

READ THIS MANUAL CAREFULLY BEFORE USING THE PUMP

UNPACKING SAFETY GUIDELINES GENERAL SAFETY INFORMATION. Operating Instructions & Maintenance Manual

INSTALLATION & OPERATION MANUAL

JET PUMP INSTALLATION MANUAL. motralec SHALLOW WELL JET PUMPS

Series: PFSWCPC75. 3/4 HP 1750 RPM 60 Hz Submersible Sewage Pump OWNER S MANUAL. Power-Flo Pumps & Systems PUMPS

SUBMERSIBLE PUMP HSE RANGE

Installation, Operation and Maintenance Manual Stancor SSD & SL Series Pumps

INSTALLATION INSTRUCTIONS MODELS S S SHALLOW WELL & CONVERTIBLE JET PUMPS PAGE 3 PAGE 8

ACHL Series Pump. Operation and Maintenance Manual Air Driven, Hand Operated High Pressure Liquid Pump

SUPER PUMP OUT SYSTEM

MODEL INSTALLATION INSTRUCTIONS. 12 Volt UTILITY PUMP

Transcription:

Centrifugal Pumps (Part Nos. PS2SS PS73SS) PS2SS Part No. Serial Number Date Purchased

Table of Contents Page Safety Messages...2 Pump Curves...2 Pump End Assembly...3 Disassembly...3 Installation...4 Maintenance...3 Electrical Hookup...4 Troubleshooting...5 Safety Messages Safety is important to us. We have included safety messages throughout this manual and for your protection. Please read and follow all directions. A safety message has a safety alert symbol followed by an explanation of what the hazard is, what can happen and what you should do to avoid injury. This is the safety alert symbol: CAUTION You can be killed or seriously injured if you don't follow instructions. ELECTRICAL SHOCK HAZARD Disconnect electrical power at the circuit breaker or fuse box before installing this product. Install where it will not come into contact with water or other liquids and where it will be weather protected. Electrically ground this product. Failure to follow these instructions can result in death, fire or electrical shock. Pump Curves 100 80 The safety alert symbol and "WARNING" or "CAUTION" will precede all safety messages: Head (Feet) 60 40 3/4 hp 1 hp 1 1/2 hp 2 hp 3 hp WARNING You will be killed or seriously injured if you don't follow instructions. 20 GPM 1/2 hp 10 20 30 40 50 60 70 80 90 100 110 120 130 140 2

Pump End Assembly 1. Clean and inspect all pump parts (O-ring, seal seats, motor shaft, etc.). 2. Apply sealant in bracket bore hole and possibly around seal case according to sealant instructions. For SS seal, chamfer the edge of the bracket bore hole. 3. Press carbon graphite seal into bracket while taking care not to damage carbon graphite face. 4. Place slinger (rubber washer) over motor shaft and mount bracket to motor. 5. Carefully lubricate boot or O-ring around ceramic piece and press into impeller (if ceramic has O-ring, the marked side goes in). Use glycerine for EPDM. 6. Sparingly lubricate carbon graphite and ceramic sealing surfaces. Water, glycerine or a lightweight machine oil may be used, depending on the elastomers used in the pump. Do not use silicon lubricants or grease! 7. Thread impeller onto shaft and tighten. If required, remove motor end cap and use a screwdriver on the back of motor shaft to prevent shaft rotation while tightening. Replace motor end cap. 8. Electrically, connect the motor so that the impeller will rotate CCW when facing the pump with the motor toward the rear. Incorrect rotation will damage the pump and void the warranty! For 3-phase power, electrically check rotation of impeller with volute disassembled from bracket. If pump end is assembled and rotation is incorrect, serious damage to pump end assembly will occur even if the switch is "quickly bumped." If rotation is incorrect, simply exchange any two leads. 9. Seat O-ring in volute slot and assembly volute to bracket. 10. Install drain plug with its O-ring in volute drain hole. Figure 1 BRACKET IMPELLER M BOLT VOLUTE SEAL WASHER & LOCK NUT DRAIN PLUG & O-RING LARGE O-RING P-BOLT & WASHER Disassembly WARNING Shut off power to motor before disconnecting any electrical wiring from the back of the motor. 1. Disassemble the bracket motor assembly from the volute, by removing the seven 1 /4" x 2 1 /2" cap screws. (The volute may be left in-line.) 2. Remove cap covering shaft at back of motor. Using a large screwdriver, prevent shaft rotation while unscrewing impeller. 3. Remove ceramic piece from impeller. 4. Detach bracket from motor. 5. Remove carbon graphite seal from bracket by pressing out from the back. Do not dig out from the front! 3

Installation Please read carefully! When properly installed the Sweetwater pump will provide dependable, trouble-free service. 1. Locate pump as near the source to be pumped as possible. A flooded suction situation is preferred. The pump is not selfpriming; therefore, if the fluid level is below the pump, a foot valve must be installed and the pump primed prior to startup. 2. Mount motor base to a secure, immobile foundation. 3. Use only plastic fittings on both the intake and discharge ports. Seal pipe connections with PTFE paste. These fittings should be self-supported and in neutral alignment with each port. Forcing the fittings into alignment may cause premature line failure or damage to the pump volute. 4. Never restrict the intake. Keep both input and discharge lines as free of elbows and valves as possible. Always use pipe of adequate diameter. This will reduce friction losses and maximize output. 5. This pump is not self-priming and must not be run dry! We recommend a flooded suction installation. Figure 2 Valve Flooded Suction Pump Warning: Do not run dry! Foot Valve Maintenance Lubricate motor per instructions on motor. Rotary seal requires no lubrication after assembly. Pump must be drained before servicing or if stored below freezing temperatures. Periodic replacement of seals may be required due to normal carbon wear. Electrical Hookup ELECTRICAL SHOCK HAZARD All electrical wiring should meet state and local ordinances. Improper wiring may not only be a safety hazard but may permanently damage the motor and/or pump. 1. Check that supply voltages match the motor's requirements. 2. Check motor wiring and connect (according to instructions on motor) to match supply voltage. Be sure of proper rotation (refer to Pump End Assembly, #8)! Improper rotation will severely damage pump and void warranty. 3. Power cord should be protected by conduit or by cable and be of proper gauge. It should be no longer than necessary. 4. Power should be drawn directly from a box with circuit breaker protection, or with a fused disconnect switch. 5. Always switch off power before repairing or servicing pump and/or motor. 4

Troubleshooting Problem Reason Remedy Motor will not rotate. Motor hums or will not rotate at correct speed. Pump operates with little or no flow. Pump loses prime. Motor or pump overheats. Improper wiring. Breaker/fuse/GFCI tripped. Overheated motor. Improper wiring. Debris in impeller/volute. Mechanical resistance to rotation. Bearing problem. Failed condenser/start switch. Pump not primed. Seal leak. Improper line voltage. Improper phase rotation. Obstruction in plumbing/impeller. Defective check or foot valve. Air introduction in inlet plumbing. Defective check or foot valve. Seal leak. Air introduction in inlet plumbing. Fluid supply low. Improper line voltage, phase, wiring. Binding motor shaft or pump parts. Inadequate ventilation. Deadheaded pump. Check for proper electrical connections to motor. Check main power supply for tripped breaker, etc. Check thermal overload on motor. Check for proper electrical connections and proper cord size and length. Check for foreign material inside pump. Remove motor and check for impeller rotation without excessive resistance. Remove motor and check shaft rotation for excessive bearing noise. Have authorized service person check condenser. Check to insure that pump is primed. Check for leaking seal. Check voltage. Check phase rotation. Check for clogged inlet port and/or impeller. Inspect check/foot valve for obstruction or failure. Check inlet lines for air leakage. Inspect check/foot valve for obstruction or failure. Check for leaking seal. Check inlet lines for air leakage. Ensure proper sizing of pump for available fluid supply. Check amperage, voltage, and phase. Check for obstruction, bearing failure, shaft distortion. Allow for airflow around pump motor. Ensure water flow at pump discharge. 5