HYGIENE INDICATORS CHEMDYE KPRO2-E250 Hygiene Monitoring System. Kit system for detecting residual protein on endoscopes and other cannulated instruments. With flexible 2.5 m SW250 swab. Vials with 0.44 ml colorimetric reagent. Instant reaction. Turns from Amber to Blue. Includes swab moisturizer per box. 50 vials + 50 SW250 swabs KPRO2-E69 Hygiene Monitoring System. Kit system for detecting residual protein on surfaces. With 6.9 cm SW69 swab. Vials with 0.44 ml colorimetric reagent. Instant reaction. Turns from Amber to Blue. Includes swab moisturizer per box. 50 vials + 50 SW69 swabs PROMICRO High sensitivity pen system for the detection and quantification of surface proteins and allergens. High absorption swab which allows the collection of samples on different types of surfaces. Detection limit: μg. Sensitivity: 0.5 μg. ISO 5883- / HTM 0-0 / HTM 0-05 00
WASH INDICATORS CHEMDYE CCDER Reprocessors. Challenge Device + luer-lock CCDER22 Reprocessors. Challenge Device + 3 luer-lock CCDER2 Reprocessors. Challenge Device + luer-lock CDWA3 Cleaning Indicator for cleaning performance tests. Challenge level: high. Allows detection of all factors affecting the outcome of cleaning process. Size: (70 x 30 mm). Initial Color: Blue Result: elimination of blue organic substance. ISO/TS 5883-5 CDWA4 Cleaning Indicator for cleaning performance tests. Challenge level: very high. Allows detection of all factors affecting the outcome of cleaning process. Size: (70 x 30 mm). Initial Color: Fuchsia. Result: elimination of fuchsia organic substance. ISO/TS 5883-5 CDWAH Holder for CDWA cleaning Indicator, stainless steel re-usable holder of great resistance and durability. Base: 32 mm wide, 72 mm long, pin at the back side. Basket: 32 mm wide, 37 long, 7 mm thick. ISO/TS 5883-5 CDWE Cleaning Indicator for endoscope cleaning performance tests in Automatic Endoscope Reprocessors. 20 2
WASH INDICATORS CHEMDYE KCCDER Reprocessors Kit. 20 indicator strips + luer-lock KCCDER22 Reprocessors Kit. Challenge Device + 20 indicator strips + 3 luer-lock KCCDER2 Reprocessors Kit. Challenge device ( 2 m x 2 mm internal diameter ) + 20 indicator strips + luer-lock KCCDER2/ Reprocessors Kit. Challenge device ( m x 2 mm internal diameter ) + 20 indicator strips + luer-lock 3
WASH INDICATORS CHEMINK IKW4 Indicator ink for washing efficiency tests in washer-disinfectors. 2 4
WASH INDICATORS INTEGRON IT27W- One-side-laminated strip (70 x 30 mm) printed with indicator ink for routine control of thermal disinfection processes, min. 90 C, A0= 600 Turns from Green to Purple IT27W-0 One-side-laminated strip (70 x 30 mm) printed with indicator ink for routine control of thermal disinfection processes, 0 min. 93 C (BGA/RKI/EPIDEMIC PROGRAM) or equivalent. Turns from Green to Purple. IT27W-5 One-side-laminated strip (70 x 30 mm) printed with indicator ink for routine control of thermal disinfection processes, 5 min. 90 C, A0= 3000 Turns from Green to Purple. IT400 Package of non-absorptive material (25 mm x 70 mm). Polypropylene strip (0 mm x 45 mm) printed with indicator ink for monitoring of High Level Disinfection processes using Liquid Peracetic Acid. Turns from Violet to Fuchsia. 00 IT40 Package of non-absorptive material (25 mm x 70 mm). Polypropylene strip (0 mm x 45 mm) printed with indicator ink for monitoring of High Level Disinfection processes using Liquid Peracetic Acid. Turns from Brown to Blue or Greenish. 00 5
All products are made in its entirety in Argentina. Bionova, Chemdye, Chemink, Integron, Cintape and Humidigene are a registered trademark of Terragene S.A.