ASTM THERMOMETERS. Range ** has auxiliary ice point

Similar documents
ISOCAL - 6 Range Europa Venus Calisto

Technical Data SPENCE ENGINEERING COMPANY, INC. 150 COLDENHAM ROAD, WALDEN, NY SD 1520 SERIES 2000 DIRECT & REVERSE ACTING

Heat Engines Lab 12 SAFETY

SERVICE MANUAL FOR ANALOG CONTROLLER MODELS

N I S T traceable calibration equipment conforms to MIL-STD-45662A.

Shriram Institute For Industrial Research, 14-15, Sadarmangala Industrial Area, Whitefield Road, Bangalore, Karnataka

U tube viscometer. Kinematic viscosity bath RASAYAN

PRECISION DC CURRENT SHUNT STANDARDS. The Most Accurate and Widely Recommended DC Shunt Available Today!

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

Direct immersion resistance thermometer

SPECIALTY WEIGHTS CALIBRATION WEIGHTS

Standard Specification for ASTM Thermometers 1

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

ASTM-API Thermometers

DigiTemp. Digital Thermometer

Ford Fabricated Steel Products

Tel-Tru Manufacturing Company World-Class Thermometers

ISO 3405 INTERNATIONAL STANDARD. Petroleum products Determination of distillation characteristics at atmospheric pressure

Selecting Weights and Certificates

Article: Sulfur Testing VPS Quality Approach By Dr Sunil Kumar Laboratory Manager Fujairah, UAE

SECTION PIPING SPECIALTIES PART 1 GENERAL 1.1 SUMMARY

Tel-Tru Manufacturing Company World-Class Thermometers

TESTING OF FUELS : FLASH AND FIRE POINT

Welcome to Garber C O R P O R AT E O V E R V I E W

Instruction Manual for HSPA Take-Up Units

Rototherm Certificates of Calibration Traceability and Quality System

Preparing the New EuroLoop Liquid Flow Facility for Accreditation. Jos van der Grinten - NMi EuroLoop

Model Name: 4 Position RPV-1

UNIVERSAL CALIBRATING MACHINES

High-strength structural bolting assemblies for preloading. Part 1: General requirements. Part 2: Suitability test for preloading

IFOA Integral Flow Orifice Assembly

SECTION METERS AND GAGES FOR HVAC PIPING

Standard Specification for ASTM Hydrometers 1

Beamex MB METROLOGY TEMPERATURE BLOCK. Portable temperature dry block delivering bath-level accuracy for industrial applications

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

RTD Insert for Temperature Sensor omniset- TPR100

OPERATING USER MANUAL for TEMPERATURE RECORDERS

PosiTest. Pull-Off Adhesion Tester. INSTRUCTION MANUAL v PosiTest AT-M (manual) PosiTest AT-A (automatic)

Penetration. Test Methods

Traceability overview

Certificate of Accreditation

Model 102B15. ICP Pressure Sensor. Installation and Operating Manual

TEL-TRU Manufacturing Co. DIGI-TEL THERMOMETERS. Replacement for Liquid-in-Glass Thermometers. m

AKM 345 Gen2. Instruction Manual. Oil Temperature Indicator AKM OTI Type 34 Winding Temperature Indicator AKM WTI Type 35. Document ID: IST EN

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

Fractional Distillation Lab Simulating The Refining of Petroleum 12/12 Integrated Science 3 Redwood High School Name : Per:

PRECISION GRANITE USA has been providing precision granite metrology products to companies worldwide including many government facilities since 1984.

CEAST - HDT & VICAT. Thermal Testing Instruments

Valveworks USA Operation and Maintenance Booklet Model FC

Certificate of Accreditation

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2017 & ANSI/NCSL Z

PRECISION GRANITE USA has been providing precision granite metrology products to companies worldwide including many government facilities since 1984.

Scope of Accreditation For Global Instrumentation Services, LLC 523 N. Sam Houston Parkway E, Suite 230 Houston, TX Gavin Lewis

STAINLESS STEEL NIST Class F

Beton Trowel nv INSTRUCTION MANUEL SLAB SAW BTCS500 - GEBABEBB BBRUBEBB BNP FORTIS: ING: BE BE

Hellenic Accreditation System. Annex F2/17 to the Certificate No SCOPE of ACCREDITATION

Tachometers and Tach/Hourmeters

Schedule. 200 C to 400 C. 400 C to 660 C C to 800 C C to 1300 C C to 1200 C. 0 C to 1700 C. 0 C to 1700 C.

Precision Thermometers for Material Testing

Model 393B31. Seismic, high sensitivity, ceramic flexural ICP accel., 10 V/g, 0.1 to 200 Hz, Installation and Operating Manual

Instruction Manual. Single-Input Thermistor Thermometer (Model )

Standard Test Method for Kinematic Viscosity of Transparent and Opaque Liquids (and Calculation of Dynamic Viscosity) 1

ASTM E 1354 Caloric Content Determination of "3M Polyurethane Adhesive Sealant 540"

Free Piston Stirling Engine Kit

Single-Input Thermocouple. Thermometers Type J, K, T

Genesys 20 Calibration and Maintenance

THE IDLE CIRCUIT AND THE PROGRESSION. We have seen how in a "basic"

EMP1 OPERATING & INSTALLATION INSTRUCTIONS

UNDERSTANDING CMM SPECIFICATIONS AND CALIBRATION METHODS

Tachometers and Tach/Hourmeters

A Guide to Dry Block Calibration

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2017. Data Weighing Systems 255 Mittel Drive Wood Dale, IL Steven A. Thomas CALIBRATION

Tri-Pac E325 / E525 Ball Valve Three-Piece Bolted Body, In-Line Maintainable, Regular and Full Port. McCANNA/MARPAC Valves RO400-R4

* T Temperature-Indicating Dial (Must be field set and calibrated to an actual thermometer)

OIML Weights & Weight Sets

TK-6024, TK-6124, TK-8024, TK-8124

The Ultimate Critical Service TRIPLE OFFSET VALVE

Model ED 400 Drying and heating chambers Classic.Line with natural convection

6109A / 7109A. Portable Calibration Baths. Four times more calibration throughput with twice the accuracy of Micro-Baths and dry-block calibrators

2 BURETS. Serialized Class A / Class B. Serialized and Certified Class A Burets with Straight Bore PTFE Stopcock

Eaton. Repair Information. Model and Piston Motors Fixed Displacement, Valve Plate Design. Medium Duty Piston Pump NO.

9142-B-P-156/AF. User s Guide. Field Metrology Well. Distribution is limited to DoD and U.S. DoD contractors only.

Comparison of IG Testing Standard. IGMA Summer Meeting August 8, 2004

PBV s Engineering Excellence At Work

CERTIFICATE OF ACCREDITATION

Model ED 720 Drying and heating chambers Classic.Line with natural convection

Temperature Regulators

Certificate of Accreditation

Certificate of Accreditation

No January, Char-Lynn. Power Steering. Parts Information. 3, 4, 6, and 12 Series Steering Contol Units

No July, Eaton. Hydraulic Motor. Repair Information. 30 Series VIS Bearingless Motor 002

Section 8 AMERICAN. Flanged Pipe

Type A10. Falk Freedom Disc Couplings Installation and Maintenance. Type A10 Sizes 85 thru 8770 (Page 1 of 5)

Cooling System Description and Operation

Standard Test Method for Dropping Point of Lubricating Grease 1

Heating Methods. Reflux and Distillation

Closed Cup Flash Point Tester

W91/W94 Series TEMPERATURE REGULATORS. Self-Operated Temperature Regulators. Design & Operation W91 Non-Indicating W94 Dial Thermometer

Model ED 400 Drying and heating chambers Classic.Line with natural convection

Model 086C05. Installation and Operating Manual

Transcription:

Only From ASTM THERMOMETERS Also available with ISO17025 Accredited Calibrations Made in strict accordance to the new ASTM Standard E2251 "Standard Specification for Liquid-in-Glass ASTM Thermometers with Low-Hazard Precision Liquids" Miller & Weber Part # ASTM # Range ** has auxiliary ice point Divisions T-3950/S12C S12C -20 to 102 C 0.2 C T-3950/S12F S12F -5 to 215 F 0.5 F T-3950/S56C S56C 19 to 35 C 0.02 C T-3950/S56F S56F 66 to 95 F 0.05 F T-3950/S59C S59C -18 to 82 C 0.5 C T-3950/S59F** S59F 0 to 180 F 1.0 F T-3950/S62C S62C -38 to +2 C 0.1 C T-3950/S62F S62F -36 to + 35 F 0.2 F T-3950/S63C S63C -8 to 32 C 0.1 C T-3950/S63F S63F 18 to 89 F 0.2 F T-3950/S64C S64C 25 to 55 C ** 0.1 C T-3950/S64F S64F 77 to 131 F ** 0.2 F T-3950/S65C S65C 50 to 80 C ** 0.1 C T-3950/S65F S65F 122 to 176 F ** 0.2 F T-3950/S66C S66C 75 to 105 C ** 0.1 C T-3950/S66F S66F 167 to 221 F ** 0.2 F T-3950/S67C S67C 95 to 155 C ** 0.2 C T-3950/S67F S67F 203 to 311 F ** 0.5 F T-3950/S91C S91C 20 to 50 C 0.1 C T-3950/S116C S116C 18.9 to 25.1 C 0.01 C T-3950/S117C S117C 23.9 to 30.1 C 0.01 C T-3950/S120C S120C 38.5 to 41.5 C ** 0.05 C **This is the commercial ASTM S59F. For the thermometer equivalent to NSN 6685-01-515-2149, please contact us directly. 1637 George Street, Ridgewood, NY 11385 Telephone: (718) 821-7110 Fax: (718) 821-1673 email: info@millerweber.com

THERMOMETERS IN ASTM* RANGES The thermometers listed below are made to substitute for the mercury ASTM thermometers listed in ASTM E 1. Miller & Weber Part # Range ** has auxiliary ice point Divisions T-3950/S5C -38 to 50 C 1.0 C T-3950/S5F -36 to 120 F 2.0 F T-3950/S18C 34 to 42 C 0.1 C T-3950/S18F 94 to 108 F 0.2 F T-3950/S19C 49 to 57 C 0.1 C T-3950/S19F 120 to 134 F 0.2 F T-3950/S22C 95 to 103 C 0.1 C T-3950/S22F 204 to 218 F 0.2 F T-3950/S58C -34 to 49 C 0.5 C T-3950/S58F -30 to 120 F 1.0 C T-3950/S121C 98.6 to 101.4 C ** 0.05 C T-3950/S122C -45 to -35 C 0.1 C T-3950/S123C -35 to -25 C 0.1 C T-3950/S124C -25 to -15 C 0.1 C T-3950/S125C -15 to -5 C 0.1 C T-3950/S130C -7 to 105 C 0.5 C T-3950/S130F 20 to 220 F 1.0 C NOTE: We are adding listings each week. If you have a requirement for a thermometer not listed here, please call and we will be happy to quote. ALL THERMOMETERS ABOVE ARE AVAILABLE WITH ISO 17025 ACCREDITED CALIBRATION. 1637 George Street, Ridgewood, NY 11385 Telephone: (718) 821-7110 Fax: (718) 821-1673 email: info@millerweber.com

CERTIFIED ASTM THERMOMETERS 1637 George Street, Ridgewood, NY 11385 Telephone: (718) 821-7110 Fax: (718) 821-1673 email: info@millerweber.com (All PerformaTherm ASTM thermometers are available with Report of Calibration. The items listed below are certified at the ASTM Calibration and Verification Temperatures found in ASTM E 2251) Miller & Weber Part # ASTM # Range ** has aux ice pt Divisions With Report of Calibration at: In Case T-7950/S12CFC S12C -20/102 C 0.2 C -20, -10, 0, 10, 20, 30, 40, 50, 60, 70, 80, 90 & 100 C Y T-7950/S56CFC S56C 19/35 C 0.02 C Every 2 from 19 C Y T-3950/S62CFC S62C -38/+2 C 0.1 C -37, -30, -20, -10 & 0 C N T-7950/S62CFC S62C -38/+2 C 0.1 C -37, -30, -20, -10 & 0 C Y T-3950/S63CFC S63C -8/32 C 0.1 C -7, 0, 10, 20 & 30 C N T-7950/S63CFC S63C -8/32 C 0.1 C -7, 0, 10, 20 & 30 C Y T-3950/S64CFC S64C 25/55 C ** 0.1 C 0, 25, 35, 45 & 55 C N T-7950/S64CFC S64C 25/55 C ** 0.1 C 0, 25, 35, 45 & 55 C Y T-3950/S65CFC S65C 50/80 C ** 0.1 C 0, 50, 60, 70 & 80 C N T-7950/S65CFC S65C 50/80 C ** 0.1 C 0, 50, 60, 70 & 80 C Y T-3950/S66CFC S66C 75/105 C ** 0.1 C 0, 75, 85, 95 & 105 C N T-7950/S66CFC S66C 75/105 C ** 0.1 C 0, 75, 85, 95 & 105 C Y T-3950/S67CFC S67C 95/155 C** 0.2 C 0, 100, 110, 130 & 150 C N T-7950/S67CFC S67C 95/155 C** 0.2 C 0, 100, 110, 130 & 150 C Y T-7950/S6266C NA C Set (S62C thru S66C) 0.1 C All Y T-7950/S91CFC S91C 20/50 C 0.1 C 20, 30, 40 & 50 C Y T-3950/S116C S116C 18.9/25.1 C 0.01 C Every 1 from 19 to 25 C N T-3950/S117C S117C 23.9/30.1 C 0.01 C Every 1 from 24 to 30 C N T-7950/S120CFC S120C 38.6/41.4 C** 0.05 C 0, 40 & 41 C Y T-7950/S12FFC S12F -5/215 F 0.5 F -5, 15, 32, 60, 85, 110, 135, 160, 185 & 210 F Y T-7950/S56FFC S56F 66/95 F 0.05 F Every 4 from 66 F including 95 F Y T-3950/S62FFC S62F -36/+35 F 0.2 F -35, -15, 0, 15 & 32 F N T-7950/S62FFC S62F -36/+35 F 0.2 F -35, -15, 0, 15 & 32 F Y T-3950/S63FFC S63F 18/89 F 0.2 F 20, 32, 50, 70 & 88 F N T-7950/S63FFC S63F 18/89 F 0.2 F 20, 32, 50, 70 & 88 F Y T-3950/S64FFC S64F 77/131 F ** 0.2 F 32, 80, 95, 115 & 130 F N T-7950/S64FFC S64F 77/131 F ** 0.2 F 32, 80, 95, 115 & 130 F Y T-3950/S65FFC S65F 122/176 F ** 0.2 F 32, 125, 145, 160 & 175 F N T-7950/S65FFC S65F 122/176 F ** 0.2 F 32, 125, 145, 160 & 175 F Y T-3950/S66FFC S66F 167/221 F ** 0.2 F 32, 168, 185, 200 & 220 F N T-7950/S66FFC S66F 167/221 F ** 0.2 F 32, 168, 185, 200 & 220 F Y T-3950/S67FFC S67F 203/311 F ** 0.5 F 32, 205, 240, 275 & 310 F N T-7950/S67FFC S67F 203/311 F ** 0.5 F 32, 205, 240, 275 & 310 F Y T-7950/S6266F NA F Set (S62F thru S66F) 0.2 F All Y

ISO/IEC 17025 Accredited Certificate # AC-1209 Non-Mercury Precision Thermometers Manufactured to ANSI/SAMA Z 236.1 Mercury Thermometer Specifications Item Number Description ANSI/SAMA Tolerance T-3900S/S110CT 12" -20/110 C, 0.5, Total Immersion ±0.5 C full scale T-3940S/S110CP 12" -20/110 C, 0.5, 76 mm Immersion ±1 C full scale T-3970S/S230FT 12" 0/230 F, 1, Total Immersion ±1 F full scale T-3905S/S230FP 12" 0/230 F, 1, 76 mm Immersion ±2 F full scale T-3900/SCT40 18" -1/51 C, 0.1, Total Immersion ±0.3 C full scale T-3900/SCT45 24" -1/101 C, 0.1, Total Immersion ±0.3 C full scale T-3900/SCT50 24" -1/201 C, 0.2, Total Immersion ±0.4 C up to 100 C, ±0.5 C above 100 C T-3920/SCP40 18" -1/51 C, 0.1, 76 mm Immersion ±1 C full scale T-3920/SCP45 24" -1/101 C, 0.1, 76 mm Immersion ±1 C full scale T-3920/SCP50 24" -1/201 C, 0.2, 76 mm Immersion ±1 C up to 100 C, ±1.5 C above 100 C T-3925/SFT40 18" 30/124 F, 0.2, Total Immersion ±0.5 F full scale T-3925/SFT45 24" 30/214 F, 0.2, Total Immersion ±0.5 F full scale T-3925/SFT50 24" 30/394 F, 0.5, Total Immersion ±1 F up to 212 F, ±2 F above 212 F T-3926/SFP40 18" 30/124 F, 0.2, 76 mm Immersion ±2 F full scale T-3926/SFP45 24" 30/214 F, 0.2, 76 mm Immersion ±2 F full scale T-3926/SFP50 24" 30/394 F, 0.5, 76 mm Immersion ±2 F up to 212 F, ±3 F above 212 F 1637 George Street Ridgewood, NY 11385 Telephone: (718) 821-7110 Fax: (718) 821-1673 Email: info@millerweber.com

Non-Mercury Calibrated Thermometers ISO/IEC 17025 Accredited Certificate # AC-1209 ISO17025 Accredited, NIST Traceable Report of Calibration supplied with each of these general purpose PerformaTherm thermometers. Total immersion thermometers have tolerances and uncertainties of mercury thermometers. Partial immersion thermometers will repeat with tolerances and uncertainties of mercury thermometers when emergent stem temperature corrections are performed. All partial immersion thermometers supplied with emergent stem temperature data, formulae and coefficients of thermal expansion. Catalog # Length Temperature Range Divisions Immersion Temperatures Calibrated T-7900S/S110CTFC 12 (305mm) -20 to 110 C 0.5 C Total 0, 37, 56 & 100 C T-7940S/S110CPFC 12 (305 mm) -20 to 110 C 0.5 C 76 mm 0, 37, 56 & 100 C T-7970S/S230FTFC 12 (305mm) 0 to 230 F 1 F Total 32, 122 & 212 F T-7905S/S230FPFC T-7900/SCT40FC T-7900/SCT45FC T-7900/SCT50FC T-7920/SCP40FC T-7920/SCP45FC T-7920/SCP50FC T-7925/SFT40FC T-7925/SFT45FC T-7925/SFT50FC T-7926/SFP40FC T-7926/SFP45FC T-7926/SFP50FC 12 (305 mm) 18 (460 mm) 18 (460 mm) 18 (460 mm) 18 (460 mm) 0 to 230 F 1 F 76 mm 32, 122 & 212 F -1 to 51 C 0.1 C Total -1 to 101 C 0.1 C Total -1 to 201 C 0.2 C Total -1 to 51 C 0.1 C 76 mm -1 to 101 C 0.1 C 76 mm -1 to 201 C 0.2 C 76 mm 30 to 124 F 0.2 F Total 30 to 214 F 0.2 F Total 30 to 394 F 0.5 F Total 30 to 124 F 0.2 F 76 mm 30 to 214 F 0.2 F 76 mm 30 to 394 F 0.5 F 76 mm ALL ITEMS SUPPLIED IN PLUSH LINED CASES AS PICTURED ABOVE. 0, 10, 20, 30, 37, 40 & 50 C 0, 10, 20, 30, 37, 40, 50, 60, 70, 80, 90 & 100 C 0, 20, 40, 60, 80, 100, 120, 140, 160, 180 & 200 C 0, 10, 20, 30, 37, 40 & 50 C 0, 10, 20, 30, 37, 40, 50, 60, 70, 80, 90 & 100 C 0, 20, 40, 60, 80, 100, 120, 140, 160, 180 & 200 C 32, 52, 72, 92, 112 & 122 F 32, 52, 72, 92, 112, 132, 152, 172, 192 & 212 F 32, 70, 120, 170, 220, 270, 340 & 390 F 32, 52, 72, 92, 112 & 122 F 32, 52, 72, 92, 112, 132, 152, 172, 192 & 212 F 32, 70, 120, 170, 220, 270, 340 & 390 F 1637 George Street Ridgewood, NY 11385 Telephone: (718) 821-7110 Fax: (718) 821-1673 Email: info@millerweber.com

Only from Miller & Weber, Inc. Walls are made of heavy glass Use as a stirring rod! 10mm O.D. Glass Reinforced tips 305 MM Overall Length Blue liquid on white background Calibrated for 76 mm Immersion Tolerance ±1 scale division (same as mercury!) Ask about our mercury thermometer exchange program!! Miller & Weber Part # Description T-3975/JumboA T-3910/JumboA -20 to 110 C, 1 Divisions -4 to 230 F, 2 Divisions 1637 George Street Ridgewood, NY 11385 Telephone: (718) 821-7110 Fax: (718) 821-1673 Email: info@millerweber.com

CALORIMETRY THERMOMETERS HAACP THERMOMETERS SAMA PRECISION THERMOMETERS PAINT & COATING THERMOMETERS NOW ALL AVAILABLE WITH PerformaTherm Liquid! No More Hazards! No More Mess! Picture from Miller & Weber, Inc. Booth PITTCON 2002

PLEASE READ BEFORE USING YOUR NEW PERFORMATHERM THERMOMETER GENERAL INSTRUCTIONS FOR USE Since PerformaTherm thermometers react very quickly to changes in temperature being measured, it is important that when running the liquid from a higher temperature to a lower temperature (in the down direction) you do not surpass a rate greater than 20 per minute. When going from a lower to a higher temperature there is no restriction on rate of rise. PerformaTherm thermometers react to temperature similarly to mercury thermometers. Once at desired temperature, leave thermometer in medium being tested three minutes before reading. ICE POINT READINGS Place the thermometer in a beaker of room temperature water. GRADUALLY add chopped ice to the water so that the liquid moves no faster than 20 per minute. As the liquid approaches the Ice Point, then place the thermometer directly into a prepared ice bath. Allow the thermometer to remain in the ice bath three minutes before reading temperature. RE-JOINING LIQUID SEPARATIONS All thermometers, including PerformaTherm, experience occasional separations, especially during transit. In order to obtain true and accurate readings; please follow the re-joining instructions below that apply to your thermometer. The particular identification will be found on the back of your PerformaTherm thermometer. S62C & S62F This low-range thermometer is normally joined in one of the two upper chambers. If the separation is in the lower part of the scale, run the liquid down (no faster than 20 per minute) using dry ice and alcohol. When all the liquid is in the bulb, tap the bulb gently so the separations rejoin. Allow the thermometer to stand at room temperature while the liquid rises. DO NOT TOUCH THE BULB WITH YOUR HAND AS THIS MAY CAUSE THE BULB TO BREAK! Allow thermometer to reach room temperature before using. If the separation is below the first chamber above the scale, the liquid must be run up into the chamber and the thermometer tapped gently until the separations are joined. If the separation is slightly above the first chamber, dip the bulb into plain chopped ice until all liquid is in the chamber. Continue to tap the thermometer until the liquid is at the bottom of the bottom chamber. SLOWLY run the liquid in the bore into the chamber (tapping the Page 1 of 2

bulb, if needed, to keep the liquid in the chamber at the bottom of the chamber). When both liquids meet, tap the thermometer gently until they join. Allow the thermometer to reach room temperature before using. If the separation is between the chambers, using regular chopped ice, bring the liquid slowly into the lower chamber and join the two liquids following the instructions above. If the separation is in the top chamber, prepare a cup of boiling water and a cup of warm water. Place the TOP of the thermometer, including the top chamber, into boiling water for at least two minutes until the liquid joins together into the bottom of the chamber. Now, place the thermometer s bulb into the warm water so the liquid in the bore rises and joins together with the separation in the top chamber. Gentle tapping may be required to re-join. Maintain the thermometer in warm water and allow to cool naturally until it reaches the lower chamber temperature. S63C & S63F This low range thermometer may be joined in the bulb or the top chamber. If the separation is below the top chamber, slowly draw the liquid down into the bulb using a mixture of dry ice and alcohol. When all the liquid is in the bulb, tap the thermometer gently. This should cause the separation to join. Allow the thermometer to warm up naturally to room temperature before using. DO NOT TOUCH THE BULB WITH YOUR HAND AS THIS COULD CAUSE THE BULB TO BREAK. If the separation is in the top chamber, prepare a cup of boiling water and a cup of warm water. Place the TOP of the thermometer, including the top chamber, into boiling water for at least two minutes until the liquid joins together in the bottom of the chamber. Now place the thermometer into the warm water so the liquid in the bore rises and joins together with the separation in the top chamber. Gentle tapping may be required to re-join. Maintain the thermometer in warm water and allow to cool naturally until it reaches room temperature. S64C & S64F, S65C & S65F, S66C & S66F These three ranges can be joined the same as previously explained. They each have a contraction chamber between the ice point and the first line and a chamber at the top of the thermometer. If the separation is between the bulb and ice point, draw the liquid into the bulb using a mixture of dry ice and alcohol. When the liquid is in the bulb, tap the thermometer gently until the liquid is joined. Allow the thermometer to warm to room temperature naturally. DO NOT TOUCH THE BULB WITH YOUR HAND AS THIS COULD CAUSE THE BULB TO BREAK. If the separation is between the contraction chamber and the top line of the thermometer range, draw the liquid down into the bottom of the contraction chamber using either a mixture of dry ice and alcohol or chopped ice. Warm the bulb so the two liquids join together. Allow the thermometer to cool down to room temperature naturally. If the separation is above the scale or in the top chamber, prepare a cup of boiling water and a warm water bath. Place the TOP of the thermometer, including the top chamber, into boiling water for at least two minutes until the liquid joins together into the bottom of the chamber. Place the thermometer into the warm bath (bulb down) so the liquid in the bore rises and joins together with the separation in the top chamber. Gentle tapping may be required to re-join. Maintain the thermometer in the warm bath and allow to cool naturally until it reaches room temperature. Please contact us if you require further information or technical assistance: 1637 George Street Ridgewood, NY 11385 Telephone: (718) 821-7110 Fax: (718) 821-1673 Email: info@millerweber.com Visit our website at: www.millerweber.com PerformaTherm is a registered Trademark of Miller & Weber, Inc. Page 2 of 2