Digital-Control and Programmable DC Power Supply Models: , , , & User Manual

Similar documents
Stepper Motor Drive. Description: Specifications:

MC 5% Series. Construction. Power Rating and Dimension. Features: Page <1> 07/04/12 V1.1. Dimension. Width (W) ± Series. Height (H) ±0.

GBPC15,25,35- Series. Features: Page <1> 10/08/10 V1.1

Switchgear Wires. Specifications: Page <1> 21/12/11 V1.1. Description : 16 mm 2 flex plain copper, PVC insulated, 600 / 1,000 V, type BK, BS 6231

Pushbutton Switches Sub-Miniature

Festoon Series. Features: Applications: Festoon 37 mm, 3 LEDs. Specifications: Festoon 37 mm, 6 LEDs. Page <1> 26/03/12 V1.1

LAVOLTA DC REGULATED POWER SUPPLY BPS-305

MC 1% Series Thick Film Chip Resistors

Thick Film Chip Resistors

BENCHTOP INSTRUMENT. Single Channel DC Power Supply SL Series Operation Manual V1.0

FG Series, 230V ac Toroidal Single Primary Transformers

Slimline Axial Flow Fans 80mm 92mm 119mm

Type Number Symbol Value Units

Fast Acting Fuse SMD Thin Film

Wire Wound Chip Inductor Ferrite

Prototyping and Soldering Kit UK

Mains Flex Oval/Round 2-3 Core

Multi Layer Ceramic Capacitor

CIRCUIT-TEST OPERATION MANUAL. Switching Mode Power Supply with Remote Sensing PSC V 5A / 0-27V 3A / 0-36V 2.2A (80W)

SSP-7080 USER MANUAL. 80W Constant Power Switching Mode Power Supply with Master & Slave Remote Sensing. Rev /

3000 Series Operation Manual

CB Series Tantalum Capacitors

DC POWER SUPPLY ALIMENTATION C.C.

Sorensen XG 1700 Series 1700 W A Watt, 1U Programmable DC Power Supplies V. Key Features. Key Modes

ISO-TECH IPS1810H and IPS1603D DC power supply ISO-TECH IPS 1810H et IPS 1603D Alimentation électrique c.c.

99 Washington Street Melrose, MA Fax TestEquipmentDepot.com. Instruction Manual. Model 1672 Triple Output Power Supply

ALR output Powerfull PROGRAMMABLE POWER SUPPLY 640 WATTS 0-32V 0-20A POWERFUL. Specifications

1 Moulded resin 2 Electrode (Ag) 3 Ferrite core 4 Magnet wire

Blade Fuses - Illuminated Mini Blade

Variable Regulated Voltage Power Supply Instruction Manual Model XP-605 / XP-752A

EPS/ELA-Series User Manual EPS/ELA 250W

High Power Chip Resistor

90W DC Power Supply. User Manual. 99 Washington Street Melrose, MA Phone Toll Free

Triple Output Power Supply

DUAL 60V 20A POWER FLEX POWER SUPPLY INSTRUCTION MANUAL

Thick Film Low Ohm Chip Resistors

HT3003PB HT3005PB MULTI-OUTPUT DC REGULATED POWER SUPPLY

BENCHTOP INSTRUMENT. Multi-channel DC Power Supply TP2000N/TP2000PU/TP4000N Series Operation Manual V1.0

Surface Mount Thick Film Resistor MCWR Series

High Voltage Thick Film Chip Resistor MCHVR Series

PORTABLE POWER SUPPLY MODEL NUMBER VMS-1 VERSION 1.0

Thick Film Chip Resistors

DC POWER SUPPLY (Switching mode)

& HIGH CURRENT DC POWER SUPPLIES INSTRUCTION MANUAL

Harris IRT Enterprises Digital Resistance Tester Model XP

KEPCO Will Point You In The Right Direction!

SERVICE MANUAL STARTER 2100 Bench ph Meter STARTER 3100 Bench ph Meter STARTER 3100C Bench ph Meter

Triple Output High Resolution Power Supply. User Manual

DC REGULATED POWER SUPPLY

Switching DC Power Supply

On Line UPS. LUC 1000E / LUC 2000E / LUC 3000E User Manual

Portable Solar Power Battery Pack User's Manual

Informer Compact Series

SERVICE MANUAL. STARTER Portable Meter ST300 ST300C ST300D ST400D. Ohaus Corporation, 7 Campus Drive, Suite 310, Parsippany, NJ (973)

BITMAIN. APW PSU Series User Guide

INSTALLATION INFORMATION

Automotive and Anti-Sulfuration Chip Resistor 0603

Model 1672, 1673 Triple Output Power Supply

High Accuracy Series REGULATED DC POWER SUPPLY. User s Manual

Observe all necessary safety precautions when controlling the soft starter remotely. Alert personnel that machinery may start without warning.

INSTRUCTION MANUAL BIPOLAR POWER SUPPLY PBA SERIES OPTIONAL RACK-MOUNTING ATTACHMENT OM-21E PRINTED IN JAPAN B

DC REGULATED POWER SUPPLY

99 Washington Street Melrose, MA Fax TestEquipmentDepot.com. Instruction Manual. Model 2831D 4 ½ Digit True RMS Digital Multimeter

FP-100 Fuel Pressure and Ammeter Indicator Page 1 of 16. All specification subject to change Aerospace Logic Inc.

USER MANUAL. IPS home inverters with UPS function. IPS home inverter manual

Sorensen XG Series / XTR Series W A. 850 W, 1U Half Rack Programmable DC Power Supplies V

Power your day-to-day when others are power-less. Humless Sentinel User s Guide.

Uninterruptible Power System

Uninterruptible Power System

Dawson DDM190D. Digital Multimeter User s Manual

Installation Guide Smart-UPS 1200/1500 VA 100/120/230 Vac Rack-Mount 1U

The 3 kw Models will accept 200*/230 VAC single phase and 200*/208 VAC three phase input power.

INTRODUCTION. Specifications. Operating voltage range:

βeta 20A AUTO 12V/24V SOLAR CHARGE CONTROLLER WITH REMOTE METER

Dawson DAN100. Analog Multimeter User s Manual

CAN-Translator. User s guide

D&D Motor Systems, Inc.

TPMS TP200 USER S MANUAL

Induction Power Supplies

OPERATING AND MAINTENANCE MANUAL. Primary Current Injection Test Set. 750ADM-H mk2

WENS30C Loop Calibrator

User Manual Solar Charge Controller 3KW

Powerful Solutions DHP - Introduction

Phoenix Inverter

BMS SV 24S for 2S-24S LiPo, LiFe & LiTO&others Low power consumption High accuracy 2.8 TFT LCD display Programmable

Digital/Analog Megohmmeter Model 1026

CX-SERIES ADVANCED BATTERY CHARGER

Sierra 80 Volt Brushless DC Motor Controller Product Specification

Item ref: UK & UK MTB01 & MTB02 DIGITAL MULTITESTERS. User Manual

ASTROAI USER MANUAL DIGITAL MULTIMETER. NOTE: Fully read and understand this manual before using this instrument.

OVERVIEW OF CONTROLS

Pulsar Evolution 1500 / 1500 Rack 1100 / 1100 Rack 800 / 800 Rack 500 Rack

CLA-VAL e-drive-34. User Manual. Motorised Pilots. CLA-VAL Europe LIN072UE - 04/16

USERS MANUAL MCD REMOTE OPERATOR

1. INTRODUCTION SYSTEM DESCRIPTION Front Panel CONNECTION AND OPERATION TROUBLESHOOTING...8

BBC-3140 USER MANUAL DC-DC CHARGER / BATTERY EQUALIZER / VOLTAGE REDUCER

Safety Precautions. Damages resulting from failure to observe these safety precautions are exempt from any legal claims whatever.

Uninterruptible Power System

GoSafe TPMS 100 USER S MANUAL. Copyright 2016, PAPAGO Inc., All Right reserved.

Ag Features. Multi-Stage Charging. Solar Panel or DC Input. Maximum Power Point Tracking (MPPT) Very Low Power Consumption

Transcription:

Digital-Control and Programmable DC Power Supply Models: 72-2535, 72-2540, 72-2545, 72-2550 & 72-10480 User Manual Page <1> 19/05/16 V1.0

Safety Symbols This chapter contains important safety instructions that you must follow when operating the Tenma power supply and when keeping it in storage. Read the following before any operation to insure your safety and to keep the best condition for the Tenma power supply. Safety Symbols These safety symbols may appear in this manual or on the series. WARNING DANGER High Voltage. Earth (ground) Terminal Safety Instruction Safety Guidelines Do not block or obstruct the cooling fan vent opening. Avoid severe impacts or rough handling that leads to damage. Do not discharge static electricity. Do not disassemble unless you are qualified as service personnel. AC Input AC Input Voltage : 110V / 120V / 220V / 230V, 50 / 60Hz Connect the protective grounding conduct or of the AC power cord to an earth ground, to avoid electrical shock. Operation Environment Location: Indoor, no direct sunlight, dust free, almost non-conductive pollution (note below) Relative Humidity: < 80% Altitude: < 2000m Temperature: 0-40 C Storage environment Location: Indoor Relative Humidity: < 70% Temperature: -10-70 C Page <2> 19/05/16 V1.0

Fuse Model 110/ 120V 220 /230V 72-10480 T4A/ 250V T2A/ 250V 72-2535 T5A/ 250V T3A/ 250V 72-2540 T5A/ 250V T3A/ 250V 72-2545 T5A/ 250V T3A/ 250V 72-2550 T5A/250 T3A/250V To ensure fire protection, replace the fuse only with the specified type and rating. Disconnect the power cord before fuse replacement. Make sure the cause of fuse blowout is fixed before fuse replacement. Series Lineup/Main Features Model V Meter A Meter USB Resolution 72-10480 4 digit 4 digit No / 72-2535 4 digit 4 digit Yes / 72-2540 4 digit 4 digit Yes / 72-2545 4 digit 4 digit Yes / 72-2550 4 digit 4 digit Yes / Performance Low noise: cooling fan controlled by heat sink temperature Compact size, light weight Operation Constant voltage / constant current operation Digital panel control 4 pairs of panel setup save / recall Coarse and fine Voltage / Current control Software calibration Beep output Key lock function Protection Overload protection Reverse polarity protection Interfaces USB/RS 232 for remote control (only for 72-2535, 72-2540, 72-2545, 72-2550) Page <3> 19/05/16 V1.0

Front Panel Overview Display Voltage level V Voltmeter displays the setup value of output voltage. Current level A Displays the setup value of output current. Condition Indication OVP OVP is the indicator of over voltage protection. When over voltage function is turned on, OVP indicator lights on; when output voltage is higher than protection setup value due to unexpected conditions, output cuts off and OVP indicator flickers; Press the key OVP again, and the power supply recovers. OCP OCP is OCP indicator. When over current function is turned on, OCP indicator lights on. C.C C.C is constant current indicator. When power supply is in the mode of constant current, this light is on. C.V C.V is constant voltage indicator. When power supply is in the mode of constant voltage, this light is on. OUT OUT is output indicator. If light on, there is voltage output in the output terminal. Storage Indication Indication of saving and recalling 5 setups stored internally. Page <4> 19/05/16 V1.0

Brief Introduction of Panel Operation Saves or recalls panel settings. For settings, 1 ~ 4 are available. For save / recall details, see Page 08. Front panel lock_out function. For details, see Page 07 Over-Current protect on/off, Pressing this key for more than 2 seconds will make beep On/OFF. Over-voltage Protect On/Off Output On/Off. Voltage-Current Setting Adjustment Digit Selector Buttons Selection Voltage / Current for Adjustment Pressing the key, the volt indicator starts to flicker; pressing it again, the ampere indicator starts to flicker. Then turn the key ADJUST and the settings of the setted voltage or current can be adjusted. On / Off main power. For power up sequence, see Page 06 Outputs voltage and current. Connects the ground (earth) terminal. Page <5> 19/05/16 V1.0

RS232 dependent interface based on remote control order (see Page 08) ; only for KAXXXXP series, such as KA3003P and soon. RS232 dependent interface based on remote control order (see Page 08); only for KAXXXXP series, such as KA3003P and so on. The power cord socket mainly accepts AC values: 115V / 230V, 50 / 60 Hz. Please refer to the fuse parameters on the back fuse label to replace the specified fuse. Make sure the correct type of fuse is installed before power up Operation Connect AC power cord Power on Power off Connecting AC power cord and selecting the corresponding AC voltage according to the back label on voltage; then connecting the AC power cord to the socket on the back panel Press the power switch to turn power on. The display initializes, showing the model of the ma chine and then showing the setting last. Press the power switch again to turn power off. Page <6> 19/05/16 V1.0

Output On / Off Panel Operation Press the Output button to turn on output; and the button LED also turns on. Press ing the Output button again to turn off the output and the LED. Note: If there are any of the following conditions, the output will automatically turn off. 1. OVP turns on and there are unusual OVP on the output terminal. 2. The setting voltage is more than that of the OVP. 3. Recalling other se tups from the memory. Beep On / Off Panel Operation By default, the beep sound is enabled. To turn off the beep, press the OCP (BEEP) button for 2 se co nds. A beep comes out and the beep setting will be turned off. To enable the beep, press the OCP (BEEP) button again for 2 seconds. Front Panel Lock Panel operation Press the LOCK button to lock the front panel button operation. The LED turns on. To unlock, press the LOCK button for 2 seconds. Output Set Panel operation 1. Connecting the load to the front port, red ( +), black (-). 2. Setting output voltage and current. Press the button Voltage/Current selection to switch voltage adjustment and current adjustment. Adjusting voltage and current with Voltage / Current Adjustment knob. By default, the Voltage and Current knob work in the coarse mode. To activate the fine mode, press the buttons to select the coarse mode or the fine mode. 3. Turning on the output and press ing the output button. The button LED turns on and displays CV or CC mode. Save / Recall Setup Save Setup Back ground Contents Panel operation Recall Set up The front panel settings can be stored into one of the four internal memories. The following list shows the se tup contents: Fine / coarse knob editing mode Beep on / off Output voltage / current level The following settings are always saved as off. Output on / off Front panel lock on / off Press one of the 4 buttons(m 1,M2,M3,M4) and the LED light turns on accordingly. After you adjust the value, it is saved automatically once it stops blinking. The front panel settings can be recalled from one of the four internal memories. Page <7> 19/05/16 V1.0

Press any button of M1 to M4, and take M1 for example; the memory of panel set tings is recalled in M1. After you recall M4, rot at e the shuttle knob and then M5 is recalled. It means the current memory is recalled that the memory indicator on the panel lights on accordingly. Note When a set ting is recalled, the out put automatically turns off. Remote Control Remote Control Setup All the models 72-2535,72-2540,72-2545,72-2550 etc. can be connected to the PC through interfaces USB/RS232 on the back of the machine and controlled by the remote control. COM setting Set up the COM port inside the PC according to the following list. Baud rate: 9600 Parity bit: None Data bit: 8 Stop bit: 1 Data flow control: None Functionality check Run this query command via the terminal application such as MTTTY (Multi-threaded TTY). *IDN? This should return the identification information: Manufacturer, model name, serial number. 72-10480 SN:xxxxxxxx Vx.xx Remote Control Procedures Entering the Remote Control Mode 1. Connecting USB 2. The power supply will automatically connect. After normal connection, there will be a tweet from the power supply itself. 3. The panel keys are locked, so the power supply can only rely on the remote control. Exiting from the Remote Control Mode 1. Closing the remote control software. 2. Disconnecting USB from the back. 3. The power supply disconnects; a tweet from the beep with the hint that the remote control is over. 4. The power supply automatically comes into the panel control mode. Page <8> 19/05/16 V1.0

FAQ Q1: The panel buttons don t work when power on. A1: The panel is locked. Press the key for over 2 seconds, and then the panel will unlock. Q2: Pressing ON/OFF, there is no out put when power on. A2: Current set up is 0. Q3: Output voltage rises slowly when out put button is on. A3: Current set up is too small. Q4: Making OCP on and pressing out put switch; and then the out put is automatically shut off. A4: Current protection value set up is too small. You could press output switch and then make OCP on. Specifications Note: The specifications below are tested under the conditions of temperature 25 C ±5 C and the warm-up for 20 minutes. Models 72-10480 72-2535 72-2540 72-2545 72-2550 Voltage Range 0-30V 0-30V 0-30V 0-60V 0-60V Current Range 0-3A 0-3A 0-5A 0-2A 0-3A Load Regulation Line Regulation Setup Resolution Setup Accuracy (25 C ±5 C) Ripple (20-20M) Temp. Coefficient Read Back Accuracy 0.01% +2mV 0.1% +5mV 0.01% +3mV 0.1% +3mV 0.5% +20mV 0.5% +5mV 1mVrms 3mArms Read Back Temp. Coefficient Reaction Time Voltage Rise Voltage Drop (10% Rated Load) 0.01% +2mV 0.1% + 0.01% +3mV 0.1% +3mV 0.5% +20mV 0.5% +5mV 1mVrms 3mArms (10% Rated Load) 0.01% +2mV 0.1% +5mV 0.01% +3mV 0.1% +3mV 0.5% +20mV 0.5% + 2mVrms 3mArms (10% Rated Load) 0.01% +2mV 0.1% +5mV 0.01% +3mV 0.1% +3mV 0.5% +30mV 0.5% +5mV 1mVrms 3mArms (10% Rated Load) 0.01% +2mV 0.1% +5mV 0.01% +3mV 0.1% +3mV 0.5% +30mV 0.5% +5mV 1mVrms 3mArms (10% Rated Load) Page <9> 19/05/16 V1.0

Interface Optional Interface (for programmable models only): RS232, USB Accessories User manual 1PC; Power Cord: 1 UK power cord and 1 Euro power Cord Weight and Dimensions(mm) 110(W) 156(H) 260(D), 72-10480/722535 3.6kg, 72-2540, 72-2545 4.3kg, 72-2550 4.8kg Important Notice : This data sheet and its contents (the Information ) belong to the members of the Premier Farnell group of companies (the Group ) or are licensed to it. No licence is granted for the use of it other than for information purposes in connection with the products to which it relates. No licence of any intellectual property rights is granted. The Information is subject to change without notice and replaces all data sheets previously supplied. The Information supplied is believed to be accurate but the Group assumes no responsibility for its accuracy or completeness, any error in or omission from it or for any use made of it. Users of this data sheet should check for themselves the Information and the suitability of the products for their purpose and not make any assumptions based on information included or omitted. Liability for loss or damage resulting from any reliance on the Information or use of it (including liability resulting from negligence or where the Group was aware of the possibility of such loss or damage arising) is excluded. This will not operate to limit or restrict the Group s liability for death or personal injury resulting from its negligence. Tenma is the registered trademark of the Group. Premier Farnell plc 2012. Page <10> 19/05/16 V1.0