EURO ECO / EURO deluxe DC 2 EURO ECO DC 2 EURO deluxe. Installation Manual DC 2. DC 2 - Control Unit conforms to DIN EN 12453

Similar documents
Door Control Panel TS 960. instructions. (Design and functions subject to change) /

SYMBOL LEGEND DANGER WARNING NOTE THIS INDICATES DANGER TO THE LIFE AND HEALTH OF THE USER IS APPROPRIATE PRECAUTIONS ARE NOT TAKEN

Operating Instructions for Control CS 300

Electrical operating instructions

Electrical operating instructions

Operating Instructions for Control CS 300

SYMBOL LEGEND DANGER WARNING NOTE THIS INDICATES DANGER TO THE LIFE AND HEALTH OF THE USER IS APPROPRIATE PRECAUTIONS ARE NOT TAKEN

Electrical operating instructions

Safety Relay Unit. Ordering Information. Ideal for Safety Door and Emergency Stop Switch Circuits for Machines in European Countries

fluid technology temperature sensors 1600 intelligent temperature sensor membrane keyboard, USB opto interface

Electrical Operating Instructions

Operating instructions Safety sensor BNS About this document. Content. 6 Disassembly and disposal 6.1 Disassembly Disposal...

Application Support. Product Information. Omron STI. Support Engineers are available at our USA headquarters from

USERS MANUAL MCD REMOTE OPERATOR

Electrical operating instructions

JUMO DELOS SI. Precision pressure transmitter with switching contacts and display. Application. Brief description. Key features.

DeltaSol AX * *

Observe all necessary safety precautions when controlling the soft starter remotely. Alert personnel that machinery may start without warning.

Operating instruction and technical description

! CAUTION! Damages on the machine possible.

Pressure regulators E/P pressure regulators Series ED02. Brochure

Operating instructions Flow monitors SI / / 2010

This manual is to be given to the end user. Optional RFI filter. Drive. Stop. Thermal protection device. Start / Reset +DC.

CS300FU SYSTEM. Pro-Line OPERATING INSTRUCTION

Temperature Sensor without thread

Electrical Operating Instructions

Long-Range Barrier Sensors

User Manual Digital Energy Uninterruptible Power Supply ML Series UPS VA GE Digital Energy Power Quality

Signaling solutions. Monolithic indicator banks Harmony type XVC. Dimensions: page 12

Tina 4A Connection block

Magnetic switch For bypass level indicators Model BGU

DEVICE STATE/BYPASSED FAILURE OVERLOAD

JUMO MIDAS S07 MA. OEM Pressure Transmitter - Maritime Approved. Applications. Brief description. Special features.

Digital display Pressure range ON/OFF output Linear output Model

User Manual. Digital Energy Uninterruptible Power Supply ML Series UPS VA. GE Digital Energy Power Quality. GE imagination at work

Mechanical Operating Instructions

CD34CNFLFxxx. Capacitive sensor, Foreground Suppression. Main features. Main functions. Description

Documentation. RM-BV4 Micro DP. Filter control

Reference Manual. UH28C High Voltage Tester

Piston Pumps with Reservoir

Commander SK. Technical Data Guide. Model sizes A to D and 2 to 6. AC variable speed drive for 3 phase induction motors

JUMO MIDAS C18 SW. OEM pressure transmitter - seawater. Applications

Internet For latest information, PDF catalogs and operation manuals

A165E CSM_A165E_DS_E_11_2

TECHNICAL DATA HYDRAULIC UNIT

ENGINE IMMOBILISER SYSTEM

DMK 331P. Industrial Pressure Transmitter. Pressure Ports With Flush Welded Stainless Steel Diaphragm

Tina 11A Connection block

System Monitoring SCHOOLMETERBOX AU

DIGITAL NET. MULTI-BEAM OPTICAL BARRIER OPTICAL OR BY WIRE SYNCHRONISM COMPLETE DIGITAL CONTROL with AGC 10 1 METRE 2 STRAIGHT OR 4 CROSSED BEAMS

USER MANUAL. IPS home inverters with UPS function. IPS home inverter manual

Lighted PushButton Switch

TAILOR MADE METAL FABRICATIONS LTD. VEHICLE ACCESS CONTROL BARRIER (VAC B)

INSPECTIONS AND MAINTENANCE

Diaphragm Valve, Metal

Electronic pressure switch. Type HEDE 10. Contents. Features. RE Edition: Replaces:

PHOENIX CONTACT - 01/2008

ZB0050 / ZB0051 ZB0070 / ZB0071

VEO. V2TF01 Art.Nr.: V2TF01P Art.Nr.: TECHNICAL DATA

MCD 200 Series Soft Starters

User Guide. Model Insulation Tester / Megohmmeter

ABB i-bus EIB EIB Power Supply Units SV/S SV/S SU/S

Operating Instructions Pedestrian Turnstile Type MPT 33

Thermal Overcurrent Circuit Breaker 3120-F...

RM B. Features. Drive Model Number Scheme. A RM6 Product Series

G3PE-Single-phase. Solid State Relays for Heaters

Accessories for Stand-alone inverter SUNNY ISLAND GENMAN

Manual. EN Appendix. Lynx Ion BMS 400A / 1000A

HS1C Interlock Switches with Solenoid

Silvertel. Ag Features. Multi-Stage Charging. Battery Reversal Protection. Reduced Power Consumption. Wide DC or AC Input Voltage Range

DMK 331P. Industrial Pressure Transmitter. Pressure Ports With Flush Welded Stainless Steel Diaphragm. accuracy according to IEC 60770: 0.

CONTROL UNIT BIOS2. Manual for installation. Programmable Control board for wings gates.

A165S/W. Separate Construction with Cylindrical 16-dia. Body. Knob-type Selector Switch (Detachable) (Cylindrical 16-dia.

BRIDGE-BOY Load limitation electronics with 1 or 3 set points

Manual motor protectors Type MS116 Type MS325 Type MS45X Type MS49X

INTECH Micro 2300-RTD6

Silver T E L E C O M. 1. Features. 2. Description. IEEE802.3af compliant. Small SIL package size - 56mm (L) x 14mm (H) Low output ripple and noise

Electrical operating instructions

Local Control Network - building controls in perfection

Infocal 9 Energy calculator for heating and cooling applications

Installation, Operating and Maintenance Instructions Garage Door Operator GA203 GA403

MS /27/2015. ABB contact for United States of America. General Information Extended Product Type: Categories

3000 Series Operation Manual

IB IL 24 PWR IN/F-D IB IL 24 PWR IN/F-D-PAC

Comfort 830 Operator system for sliding entrance doors

PHOTOCAM IV D GB F RUS I H E LV LT S NL CZ EST SK SLO RO GR TR BG

2-PHASE STEPPING MOTOR DRIVER FE Z5 DISPENSE

User's Manual. High Voltage Megohmmeter. Analog Insulation Tester plus AC Voltage and Continuity Tests. Model

Solid State Electronic Pressure Switch with Integral LED Display Model PSD-10

EQUIPMENT - MAIN BODY 7-1 SECTION 7 EQUIPMENT CONTENTS

Digital display Pressure range ON/OFF output Linear output Model

Cat. No. I526-E1-1 USER S MANUAL 3G3IV-PLKEB2 /4. Braking Resistor Units 3G3IV-PCDBR2 B/4 B. Braking Units

! WARNING To avoid risk of electrical shock, personal injury or death; disconnect power to oven before servicing, unless testing requires power.

CCO kit. Compact Change Over - 6-way switch valve with motor QUICK FACTS

Prototyping Walk through for PIC24HJ32GP202 Startup Schematic

e-ask electronic Access Security Keyless-entry

! WARNING To avoid risk of electrical shock, personal injury, or death, disconnect power to range before servicing, unless testing requires power.

Installation Guide. Index. Vehicle Canbus Integration System

Installation instructions

MINI MCR-SL-UI-UI(-SP)(-NC)

Transcription:

EURO ECO / EURO deluxe DC EURO ECO DC EURO deluxe DC DC - Control Unit conforms to DIN EN

DC EURO ECO DC EURO deluxe Connection -phase 0VAC motor power supply C L N PE PE L N M remove bridge when installing build-in-starters connection for build-in-starters C L MS N PE power supply PE L N

DC EURO ECO DC EURO deluxe Turn power on Checking red light off green light on ready to operate running up door postion up stop middle running down door postion down turn power off 9

DC EURO ECO DC EURO deluxe RT running time GB 8 9 0 0 9 8 8 9 0 0 9 D/F GB D/F 8 8 9 0 0 9 8 8 88 9 9 8 9 D/F GB 9 00 0 0 0 09 8 8 9 0 0 9 8 9 0 0 9 8 8 8 8 8 9 90 0 9 GB D/F 8 CT closing time AZ 9 9 9 AZ 9 9 9 AZ 9 9 8 8 8 8 89 9 9 9 9 99 0 0 0 0 09 9 9 AZ Turn power on. Ready to operate.

DC EURO ECO DC EURO deluxe Program II keypad external timer transponder on radio control green light Program I on no testing sec. prewarning in-active geba article 0.LSE.OL 8,k Ω testing active min. prewarning active 0

DC EURO ECO DC EURO deluxe Turn power on Checking green light on turn power off Program on CT closing time off CT closing time 0 sec. go function off prewarning in-active testing in-active 8,k Ω CT closing time on CT closing time 0 sec. go function active prewarning active testing active Turn power on ready to operate.

DC EURO ECO DC EURO deluxe The door control DC EURO is designed for hold to run control of power operated doors. The basic version is designed for hold to run operation only, and you are not allowed to use the automatic function without using additional safety devices. Safety Directions In case of using DC EURO with a permanent mains connection, an all-pole main switch with an appropriate back-up fuse must be provided. Before operation, check whether the permissible mains voltage range of the device corresponds to the local mains voltage. Please note that the door control as well as the motor are for indoor installation only. During installation, initial operation, maintenance and testing of the DC EURO it is necessary to observe the safety and accident prevention regulations valid for the specific application. ly trained electrical craftsmen should work on electrical equipment. Appliance according to the regulations The door control DC EURO is provided for the operation of sectional-, rollershutter-, folding- and swingdoors. The manufacturer of the complete installation is responsible. He must take care that the relevant standards and guidelines (e.g. DIN 98, EN 00) have to be respected. He must take care that a technical documentation of the whole installation is made available. The technical documentation must be added to the door unit., operating and use of the unit against this manual or the described technical specifications causes danger for persons and produces a liability- and obligations release. National and regional precautions and standards for the installation, as well as safety precautions of local technical standards have to be respected. Technical data Model DC EURO deluxe DC EURO ECO Supply voltage 0VAC,VA 0VAC,VA Frequency 0 Hz 0 Hz Protection class IP IP Outputs motor x NO relay contact 0 V / A x NO relay contact 0 V / A x NO relay contact 0 V / A x unregulated supply voltage x unregulated supply voltage V DC, max. 0mA V DC, max. 0mA Wiring, mm² max., mm² max. Operating temperature - 0 C to + C - 0 C to + C

DC EURO ECO DC EURO deluxe Table of contents Security instructions and technical data p DC EURO ECO -phase 0VAC motor and build-in-starters p Layout p Programming p Optional programming radio control p Troubleshooting p DC EURO deluxe -phase 0VAC motor and build-in-starters p Layout p8 Status display p9 Programming p0- Troubleshooting p Connection and Accessories for DC EURO ECO and DC EURO deluxe Limit switches p KDT / M-Series T and KDT Pushbutton p M-Series T, emergency stop / KDT and ES Series p J-Series and J-Series with Stop p LS and LS Photobeams p Safety-edge Pro-Sec-O p9 Connection and Accessories for DC EURO deluxe only LS and LS Reflector p8 LS Photobeam and 8k Ω resistor p9 Signal light 0VAC and Court light 0VAC p0 Cody wiring and programming p- Transponder wiring and programming p- Radio control programming p-

DC EURO ECO DC EURO deluxe troubleshooting Status Display Status red LED Beep Action to take No,,, No,, Yes No,, Yes 8 Yes RT error Yes,, Safety top barrier No,, Yes 0 No, 9 Security active damaged active damaged Relais damaged active Safety top barrier damaged No Power control installation change module control DIP-switch position change safety edge control pre-wired electrical bridges 8 change photobeam control limit switches 9 change fuse contact dealer 0 change the safety top barrier

DC EURO ECO DC EURO deluxe troubleshooting Status red LED action to take x,, active x,,, damaged x x Security RT,,,, error No power,9 control installation change module control DIP-switch position change safety edge control pre-wired electrical bridges 8 change photobeam control limit switches 9 change fuse contact dealer 0 change the safety top barrier

DC EURO ECO DC EURO deluxe Connection Limit Switch open Limit Switch open No Limit Switches (bridged!) Limit Switch close Limit Switch close Prelimit Switch Prelimit Switch Limit Switch open Limit Switch open Limit Switch close Limit Switch close Prelimit Switch Prelimit Switch open remove bridges when installing build-in-starters open close close pre pre

DC EURO ECO DC EURO deluxe Connection accessories KDT Pushbutton C Stop DWN UP NO NO UP DWN Stop KDT Pushbutton / M-Series T C Stop DWN UP remove bridge when installing KDT Pushbutton NO NO UP DWN

DC EURO ECO DC EURO deluxe M-Series T NO Emergency Stop / KDT remove bridge ES Series C Stop DWN UP

DC EURO ECO DC EURO deluxe Photobeams LS V GND NA C - + RX TX - + (NO) LS V GND remove bridge GND RX VDD - + GND VDD N0 C O M - + TX

DC EURO ECO DC EURO deluxe LS Reflector V GND CND VDD ON CC () RX/TX LS Reflector BU BN remove bridge Cut BK WH GY - + V GND C NO UV UB RX/TX 8

DC EURO ECO DC EURO deluxe Court light (0 VAC) / Signal light light DC EURO deluxe Signal light (0 VAC) Signal S PE L N 0

DC EURO ECO DC EURO deluxe J-Series C Stop DWN UP P remove bridge when installing J-Series with Stop J with Stop C Stop DWN UP P

DC EURO ECO DC EURO deluxe Optional accessories for DC deluxe Cody. Wiring Keypad. DIP-switch / Program Programming mode on. Insert Codes (0 different Codes with or digits) programming Insert Code (e.g.) Confirm Status Display Beep 8 98...

DC EURO ECO DC EURO deluxe. Programming mode off. Cancel Codes press micro push-button to choose press micro push-button two seconds code canceled / postion free

DC EURO ECO DC EURO deluxe LS V GND remove bridge - + RX - + C NO TX 8k V 8,kΩ SKS GND 8,kΩ Safety-edge Pro-Sec-O V SKS GR BN BN GR RX WH GND WH TX 9

DC EURO ECO DC EURO deluxe Transponder. Wiring V SKS GND IN IN. DIP-switch / Program Programming mode on

DC EURO ECO DC EURO deluxe. Programming max. 0 different Keys Key Nr. position Maximum 0 Keys. Programming mode off. Cancel Keys press micro push-button to choose press micro push-button two seconds key canceled / postion free

DC EURO ECO DC EURO deluxe Radio control (maximum 0 Transmitters). Plug in the RC Module. DIP-switch / Program programming mode on. Programming press one button for two seconds (or another transmitter) and so on. Maximum 0 Transmitters. = 0 = = and so on.. Programming mode off

DC EURO ECO DC EURO deluxe. Cancel Transmitters press micro push-button to choose press mirco push-button two seconds transmitter canceled / postion free The door control DC EURO is designed for hold to run control of power operated doors. The basic version is designed for hold to run operation only, and you are not allowed to use the automatic function without using additional safety devices.

DC EURO ECO DC EURO deluxe RT running time Program II Program I CT closing time Limit Switch open Limit Switch close safety module Pre-Limit Switch status display V / brown SKS / green green LED pushbutton radio control GND / white red LED Emergency light module V GND IN IN IMPULSE C STOP DWN UP OUT N L PE PE N L C UP DWN signal light light remove bridge marked with when installing build-in-starters 8

DC EURO ECO DC EURO deluxe Program DIP green LED radio control pushbutton Limit Switch open Limit Switch close Pre-Limit Switch red LED V / brown SKS / green GND / white light module Emergency V GND IMPULSE C STOP DWN N L PE PE N L C UP DWN UP light remove bridge marked with when installing build-in-starters

DC EURO ECO DC EURO deluxe Radio control (maximum 0 Transmitters).Plug in the RC Module pushbutton.programming mode on Press button > seconds red LED flashes fast.programming Press one button for two seconds red LED red LED flashes long once = stored (or another type of transmitter) and so on. Maximum 0 Transmitters..Programming mode off 0 seconds after the last programming the programm returns to standart mode..cancel all Transmitters Press button > seconds red LED flashes fast press button once more for > seconds red LED off = all transmitters cancelled

DC EURO ECO DC EURO deluxe X

DC EURO ECO DC EURO deluxe X

DC EURO ECO DC EURO deluxe X

DC EURO ECO DC EURO deluxe X