Electrical position feedback for actuator sizes Ø mm

Similar documents
Pneumatic control unit for decentralized automation of ELEMENT process valves

2/2-way Angle-Seat Valve for medium up to +180 C, threaded port connection, DN 15-65

Accessories for pneumatic stroke and rotary actuators CLASSIC and ELEMENT process valves

2/2-way Globe Valve for media up to +180 C, DN

2/2 way Angle-Seat Valve for medium up to C, DN15-50

2/2-way Diaphragm Valve, forged valve body, weld end and clamp connection, DN 8-100

2/2-way-Globe Valve with stainless steel design for media up to +180ºC, DN 13-50

2/2- and 3/2-way Ball Valve with pneumatic rotary actuator, plastic body, DN 10-50

Inductive conductivity meter

2/2-way Angle-Seat Valve for media up to +180 C, threaded port connection, DN 13-65

2/2-way Quarter-Turn Ball Valve in stainless steel with pneumatic rotary actuator, DN 10-50

Pneumatically operated zero dead volume T-Valve CLASSIC

Direct-acting 3/2 way plunger valve

2/2-way Diaphragm Valve with stainless steel design, weld end or clamp connection, DN 8-25

2/2-way Globe Valve for media up to +180 C, DN

3/2-way and 2 x 3/2-way Solenoid Valve for pneumatics

INSERTION flow sensor for continuous flow measurement

2/2-way Angle-Seat Valve for high-quality cryogenic applications and steam

3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics

Inductive conductivity meter

Positive displacement flowmeter

Type 2511/12. Type Type 2030 Cable plug. ASI cable plug. Dosing control. General technical data Orifice Type 6518

Electrical position indicators and combi switchboxes for linear and quarter turn valves

Positive displacement batch controller

TopControl Continuous

Electrical position indicators and combi switchboxes for linear and quarter turn valves

2/2- and 3/2-way solenoid valve for aggressive fluids

INSERTION flowmeter with paddle wheel, ELEMENT design

INLINE Flow sensor for hazardous area II 1 G/D - II 2 D - II 3 GD - I M1

Pneumatically operated zero dead volume T-valve ELEMENT for decentralized automation

Paddle-wheel flow controller for On/Off control

2/2-way Solenoid Valve with servo diaphragm, G 3/8 - G 2

2/2-way ball valve with electric rotary actuator, ball valve in plastic, DN 10-50

Pneumatically operated 2/2 way diaphragm valve with stainless steel actuator

Paddle-wheel flow controller with optical principle for On/Off control

2/2-way Globe Control Valve with stainless steel design for media up to +185ºC, DN

2/2-way Angle-Seat Control Valve with stainless steel design for media up to +185ºC, DN15-65

Direct-acting 2/2- or 3/2-way pivoted armature valve

Positive displacement flowmeter for continuous flow measurement

3/2-way Solenoid Valve, direct-acting, NC or NO

3/2-way Small Solenoid Valve, G 1/8 - G 1/4 and sub-base

2/2-way Globe Control Valve, threaded port connection, DN 10-65

2/2-way Compact Solenoid Valve, G 1/4 - G 1/2

Simple float switch TCL001/8181

Cable Plug acc. to DIN EN , Form A

INSERTION Adaptor for analysis

2/2 or 3/2 way direct acting rocker solenoid valve

2/2-way ball valve with electric rotary actuator, ball valve in stainless steel, DN 10-65

2/2 or 3/2-way Solenoid Valve, with pivoted armature and isolating diaphragm

2/2-way ball valve with electric rotary actuator, ball valve in stainless steel, DN 10-65

Paddle-wheel flow controller for On/Off control

2/2-way Solenoid Valve with servo diaphragm

Digital ph transmitter

3/2-way Rocker Solenoid Valve for pneumatic systems

Integrated Control modules

2/2 or 3/2-way Solenoid Valve, with pivoted armature and isolating diaphragm

Digital ph transmitter

Solenoid Valve Island Type 3965

2/2-way Angle Seat Valve, manually operated, for media up to +180 C

T 3965 EN Type 3965 Solenoid Valve Island To control pneumatic actuators

2/2 and 3/2-way ball valve with pneumatic rotary actuator

KINAX SR 709 Transmitter for Position Feedback

Tandem valve, welded valve configuration

Conductivity meter. PLC Solenoid valve. Type Type On/Off Diaphragm valve. Valve islands

2/2 or 3/2 way ball valve with pneumatic rotary actuator

Valve Position Monitors

3/2-way Solenoid Valve for pneumatics

3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics

2/2 Pressure operated valves

Pneumatic operated 2/2-way Diaphragm Valve

The extendable type 5470 EExi can be used for block modules or for entire valve blocks (tag connectors on top, coil spacing 19 mm).

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation

4.3 MSK SWITCH BOX MSK (SIZE I) FEATURES ADVANTAGES

POSITIONERS and Controls for Complete Valve Automation

2/2-way Angle-Seat Control Valve with stainless steel design for media up to +180ºC, DN 13-50

Type Pneumatic Control Unit. Operating Instructions

Sensor boxes SRBE Key features and product range overview

Insertion magnetic inductive flowmeter

3/2-way Miniature Rocker Solenoid Valve for pneumatic systems

3/2, 5/2, 5/2 bistable and 5/3 way pneumatic solenoid valve

Contents. FieldQ. FieldQ. Product data sheet Rev. 0 October FieldQ Valve Actuator 2. FieldQ Actuator Torque 4

Limit Switch Type 4747

Globe Valve System for continuous control. Type 8802/2301 electro-pneumatically operated globe valve + = TWO YEAR WARRANTY on this valve system

INDUCTIVE SENSORS FOR ROTARY ACTUATORS. Sense it! Connect it! Bus it! Solve it!

+ = Angle-seat Valve System for continuous control. Type 8802/2300 electro-pneumatically operated angle-seat valve

Valve Position Monitors

Type Pneumatic Control Unit. Operating Instructions

Flow-rate curves for diaphragm valves Type 2730 plastic, 2731 forged, 2731 cast, 2731 GP cold formed pipe valve body

Type Pressure Transmitter with display. Pressure Transmitter. Technical data. DN15-50 Body material. Stainless steel 316L Actuator material

Angle Seat Control Valve 7020

Data sheet pneumatic barring devices KD80-KD200

2/2 or 3/2-way Miniature Rocker Solenoid Valve

Versions. Version with K VS Version with K VS 2.0. Fig. 1: Type 3967 Solenoid Valve

HERION SERIES Indirect solenoid actuated soft seal

Multi Way Valves for Pneumatics Servo Assisted, Extendable, 10mm Wide

Actuators & Positioners Electro-Pneumatic Converters I/P Signal Converters - TEIP 11 Model without Booster Stage

Field IT Actuators & Positioners Electro-Pneumatic Converters I/P Signal Converters Standard Model with Booster Stage

97100 NAMUR. Technical data

Remote Process Actuation Control System AirLINE WAGO Remote I/Os and Fieldbusses

3/2-way and 2 x 3/2-way Rocker Solenoid Valve for pneumatics

Transcription:

Electrical position feedback for actuator sizes Ø 40-125 mm Type 1062 can be combined with Simple installation, convertible or retrofittable Self-adjusting trip cam for closed position LEDs provide local operational status and position indication Compact IP65 enclosure Mechanical, inductive or Namur limit switches Type 2000 Type 2030 Type 2031 Type 2012 Angle-seat Plastic diaphragm Diaphragm Globe The electrical position feedback is to be installed on a. Valve positions are remotely reported electrically according to switch type: - open, closed (version with a limit switch) or - open and closed (version with two switches or a switch) LEDs provide optical position indication (except with the inductive 2-wires version). Mechanical or inductive switches are housed in a compact splash-proof enclosure. The position indicator can be rotated 360 and is easily fitted to the. Technical data Material Body / cover Seal (body/cover) Cable gland Guide piece Spindle Electrical connection Ambient temperature Relative humidity Protection class Approval Mounting Installation PA6/PC EPDM PA or PVDF Brass or stainless steel Brass and stainless steel Terminal strip with cable screwing M16x1.5, cable-ø between 5 and 7 mm, wire profile max. 1 mm 2-20 to +60 C (operation and storage) [for CSA version : 0 to +60 C (operation and storage)] 80%, without condensation IP65 with mounted and tightened connectors and tightly fixed electronic module cover Limit switches acc. to VDE, IEC, UL 61010-1, CSA C22.2 n 61010-1-04, inductive limit switch in EExi (intrinsically safe) acc. to II 2 GD EEx ia II C T6, T5 or T4-T1 on piston actuator with actuator size Ø 40-125 mm As required Mechanical limit switch (per limit switch) Number of limit switches 1 or 2 Change-over contact (open and /or closed) in silver or gold Open, closed or open/closed, supply voltage Control lamp (LED) : green, red, orange 12-48 V DC/AC; [for CSA version : 12-30 V AC / 12-48 V DC] (per limit switch) < 35 ma (48 V DC) Load current (per limit switch) see table on next page Voltage drop Max. 1 V DC www.burkert.com p. 1/5

Inductive limit switch with 3-wire technology Number of limit switches 1 or 2 normally open contact (PNP) Open, closed or open/closed, supply voltage Control lamp (LED): green, red, orange 15 ma (per limit switch) Load current (per limit switch) 150 ma, per output Inductive switch with 4-wire technology Number of limit switches 1 normally open contact (PNP) Open and closed, supply voltage Control lamp (LED): green, red, orange 15 ma Load current 150 ma, per output NAMUR inductive switch with 2-wire technology Number of limit switches 1 acc. to NAMUR Open and closed Control lamp (LED): red, orange 8 V DC through isolating barrier 1.2 ma (damped) 2.1 ma (undamped) Load current not applicable Specific technical data : switch with CSA approval Degree of pollution 2 Category of installation I Altitude max. 2000 m through power source (SELV) Electrical specification for mechanical switches Voltage [V] Maximum inductive load [A] 24 DC 5 5 30 DC 2 5 50 DC 0.7 1 74 DC 0.25 0.6 Maximium resistance load [A] Principle of operation The duplication rod fitted with 2 cams moves when the opens or closes: the movement of a cam past the switch associated with it activates the latter. Target switch and cam for open When the switch is activated, the light, if there is one, comes on (or goes off on the NAMUR versions) and an electrical signal is transmitted remotely. This signal is transmitted in accordance with the NAMUR standard on one version of the 1062 ATEX. Target switch and cam for close p. 2/5

Ordering information for process system with electrical position feedback A complete process system consists of an electrical position feedback Type 1062 and a process Type 20xx. The following information is necessary for the selection of a complete system: of the desired electrical position feedback Type 1062 (see Ordering chart on p. 4) of the selected process Type 20xx (see separate data sheet for e.g. Types 2000, 2012, 2030 and 2031) You order two components and receive a complete assembled and certified. When you click on the orange box "More info." below, you will come to our website for the resp. product where you can download the datasheet. Example for process systems Electrical position feedback Type 1062 Desired process, example 2000 Angle-seat 2012 Globe 2031 Diaphragm Complete process system Type 8803-YA 2000 + 1062 Type 8803-GA 2012 + 1062 Type 8803-DB 2031 + 1062 p. 3/5

Ordering chart electrical position feedback Type 1062 (actuator size 40-125mm) Feedback with mechanical switches (change-over contact for UC) for pneumatic stroke actuator for pneumatic rotary actuator (12-48 V DC/AC) CSA approval (12-30 V AC / 12-48 V DC) (12-48 V DC/AC) closed 40 444 182 - open 40 444 181 - open/closed 40 444 183 562 568 closed 50-80 007 461-63 431 477 open 50-80 007 462-63 431 476 open/closed 50-80 007 463 562 566 63 431 478 closed 100-125 007 464-100 431 480 open 100-125 007 465-100 431 479 open/closed 100-125 007 466 562 567 100 431 481 Feedback with induction switches (normally open contacts for DC) for pneumatic stroke actuator for pneumatic rotary actuator with 3-wire technology switch switch CSA approval switch Namur (EExi) 8 V DC closed 40 444 188 open 40 552 653 560 407 562 563 560 411 open/closed 40 444 189 closed 50-80 005 422 63 431 501 open 50-80 005 434 560 408 562 564 560 412 63 431 500 open/closed 50-80 005 461 63 431 502 closed 100-125 007 467 100 431 504 open 100-125 007 468 560 409 562 565 560 413 100 431 503 open/closed 100-125 007 469 100 431 505 Electrical connection 4-pole M12 cable plug Materials PPS body and PSU cover Mechanical limit switch with contact in gold Additional Inductive limit switch with output NPN p. 4/5

Dimensions [mm] A B C Ø 40 M24 x 1.5 12 M5 Ø 50, 63 and 80 M26 x 1.5 10 M6 Ø 100 and 125 M36 x 2 16 M10 To find your nearest Bürkert facility, click on the orange box www.burkert.com In case of special application conditions, please consult for advice. Subject to alteration. Christian Bürkert GmbH & Co. KG 1401/6_EU-en_00891646 p. 5/5