THERMAL SHOCK TEST REPORT

Similar documents
CONTINUOUS IMMERSION AND DUST TEST REPORT

VIBRATION AND MECHANICAL SHOCK TEST REPORT

VIBRATION TEST REPORT

SHOCK TEST REPORT. :Cincon Electronics Co., Ltd. Hua Hsien, Taiwan, R.O.C. :EC7BW-110S15, ECLB40W-110S05, CQB60W-110S24

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

MEASUREMENT AND TEST REPORT

IESNA LM MEASURING LUMEN MAINTENANCE OF LED LIGHT SOURCES MEASUREMENT AND TEST REPORT. For

SHOCK TEST REPORT. Report No. : ENVA S9 Model Number : S9

IES LM MEASURING LUMEN MAINTENANCE OF LED LIGHT SOURCES

Product Change Notice

IESNA LM MEASURING LUMEN MAINTENANCE OF LED LIGHT SOURCES MEASUREMENT AND TEST REPORT. For

IESNA LM MEASURING LUMEN MAINTENANCE OF LED LIGHT SOURCES MEASUREMENT AND TEST REPORT. For

IESNA LM MEASURING LUMEN MAINTENANCE OF LED LIGHT SOURCES MEASUREMENT AND TEST REPORT. For

IESNA LM MEASURING LUMEN MAINTENANCE OF LED LIGHT SOURCES MEASUREMENT AND TEST REPORT. For

FEBRRUARY 22, 2008 TEST REPORT # QSH/QTH/QTE SERIES CONNECTOR SHEAR TESTING SAMTEC, INC.

SmartSensor 105 & Advance NEMA Salt Fog

HIGH SPEED MEZZANINE PRODUCT SPECIFICATION

Compliance Certification Services Inc. Report No: MIL(CS101) Date of Issue: August 12, 2009 MIL STD 461E/ F TEST REPORT.

Certificate of Calibration

ASTM Consensus Standards The Latest in Packaging Testing. Presented by: Dhuanne Dodrill President Rollprint Packaging Products, Inc.

BERKELEY ANALYTICAL 815 Harbour Way South, Suite 6 Richmond, CA Ph ; Fax

Test Group Description. Total Number. Figure 1. Unless otherwise stated, the following environmental conditions prevailed during testing:

United States Stove Company Project # Model: KP60 AKA: AP60, VG60 Type: Pellet-Fired Room Heater May 31, 2018

AUGUST 28, 2008 TEST REPORT # REV.1.1 MIXED FLOWING GAS TESTING CONNECTOR SERIES CLP S-D-A FTSH S-DV-A SAMTEC, INC.

AUGUST 28, 2008 TEST REPORT # REV.1.1 MIXED FLOWING GAS TESTING CONNECTOR SERIES SEM H-D-WT TEM H-D-WT SAMTEC, INC.

Jun06 Rev D

SPECIFICATION 宏致電子股份有限公司 桃園縣中壢市東園路 13 號. No.13, Dongyuan Rd., Jhongli City, Taoyuan County 320, Taiwan (R.O.C.)

2.0 TEST PROCEDURES AND RESULTS Vibration Test TEST EQUIPMENT AND INSTRUMENTATION QUALITY ASSURANCE PROGRAM 7 ATTACHMENTS

Harris County Tow Truck Permit Application

TEST REPORT No. : SHCCM Date : May. 17, 2013 Page: 1 of 5

SPECIFICATION AND PERFORMANCE TABLE OF CONTENT. 1. Scope Reference Documents Material and Components... 2

Verification/Report Number(s): HEARTWAY MEDICAL PRODUCTS Co., Ltd. Applicant Name/Address:

1201 North Catalina Ave. #818 Redondo Beach, CA (310) FAX (866) Classification of Air Cleanliness

Commercial-in-Confidence Ashton Old Baths Financial Model - Detailed Cashflow

600 Amp Surge Arrester

Serial Attached SCSI (SAS) Connector

Page 2 of 23 UNT150420C11

Beamex MB METROLOGY TEMPERATURE BLOCK. Portable temperature dry block delivering bath-level accuracy for industrial applications

United States Stove Company Project # Model: Breckwell SP1000 Type: Pellet-Fired Room Heater July 25, 2018

CREEP PERFORMANCE TEST REPORT. Rendered to: TREX COMPANY LLC. Seclusions Composite Privacy Fence System TYPE: Composite Fence System

PRODUCT SPECIFICATION

SFI SPECIFICATION 1.3 EFFECTIVE: MAY 23, 2000 * PRODUCT: Nitro-Methane Drag Race Multiple Disc Clutch Assemblies

TYPE APPROVAL CERTIFICATE

Report of Inspection

QSFP Copper Module Direct Attach Cable Assembly &Cage

EU RO Mutual Recognition Technical Requirements

Dispensette. Testing Instructions (SOP) 1. Introduction. May 2009

Jun 20,2014 Rev A

Customer Information. Service Engineer s Responsibilities. Agilent Cary 7000 UMS/UMA/Solids Autosampler

Aug07 Rev A All Paragraphs Revised

MEZALOK* Stacking Connector System

SAMTEC POWER CHARACTERIZATION

SFI SPECIFICATION 15.2 EFFECTIVE: MAY 1, 2008 *

SGS TEST REPORT. Page: 1 of 6 Date: April 20, itech Company LLC Christy Street, Fremont CA USA

Amendment to Test Report

VITLAB Dispenser. Standard Operating Procedure (SOP)

VIA Platform Environmental Qualification Testing Standards

SFI SPECIFICATION 35.2 EFFECTIVE: DECEMBER 29, 2014 *

TEST METHOD D6121 L-37 Load Evaluation VERSION CONDUCTED FOR: I = Invalid N = Results cannot be interpreted(refer to comment section)

SGS TEST REPORT. Page: 1 of 8 Date: April 15,2010. itech Company LLC Christy Street, Fremont CA USA

Alberta Innovates - Technology Futures ~ Fuels & Lubricants

SEP 2016 Rev D2

Environmental Test Report

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

mga research corporation

August 7, Mr. Stephen Kokenes Phone: Nomaco Inc. Fax: NMC Drive Zebulon, NC 27597

Temperature Life with or without Electrical Load Test Procedure for Electrical Connectors and Sockets

CERTIFICATE OF ACCREDITATION

4th Quarter Summary of Meteorological and Ambient Air Quality Data Kennecott Utah Copper Monitoring Stations

Life Extension Testing of Electrical Penetration Assemblies

Report Test Report

Hi-Force Limited Prospect Way Daventry Northants NN11 8PL United Kingdom Tel: +44(0) : Fax: +44(0) : Website:

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

TEST REPORT IEC Part 1: General requirements for basic safety and essential performance

TEST REPORT ENVIRONMENTAL EN 60529:1991+A1:2000

TESTING LABORATORY FOR CIVIL ENGINEERING MATERIALS

Center for Quality Engineering. Test Report No.: E0G90005

Article: Sulfur Testing VPS Quality Approach By Dr Sunil Kumar Laboratory Manager Fujairah, UAE

SAMTEC POWER CHARACTERIZATION

Testing Laboratory...: TÜV Rheinland Taiwan Ltd., Taichung Laboratory. Address...: 10F, No.219, Min Chuan Road, Taichung 403, Taiwan.

Amendment to Test Report

Product Specification QSL RF Connectors

QUALITY REQUIREMENTS FOR JUST IN TIME SERVICE PROVIDER (JIT S.P.) PROGRAM: ALL

020: 2013 CEB SPECIFICATION MINIATURE CIRCUIT BREAKER (MCB)

SFI SPECIFICATION 1.1 EFFECTIVE: NOVEMBER 9, 2001 *

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

Test certificate General construction inspection test certificate Nr. 3666/4421 -a - Fe/Wi 1. Issue ( )

FIRE ASSESSMENT REPORT FAR 4659

SAFETY AND COMPLIANCE TESTING FOR SURESTOP

Re: Online Reporting of Backflow Assembly Tests and Updates to Backflow Tester Records

Annex to the Accreditation Certificate D-PL according to DIN EN ISO/IEC 17025:2005

Brick Charger WD02. Total output power up to 55W. Capable of charging 5 devices simultaneously

Compliance Test Results. of Independently Manufactured. Automotive Replacement Headlamps. to FMVSS 108. Study I. March 18, 2003

Report Forms Test Method D 7038 L-33-1 Version Conducted For. N = Results Cannot Be Interpreted (See Comment Section)

The Participant will select one of the two Approval Categories (below) and submit the appropriate documentation.

Annex to the Accreditation Certificate D PL according to DIN EN ISO/IEC 17025:2005

Overview. Mercury Monitoring. Regulatory drivers Technology Overview Pros and Cons Alternative Hybrid Approach

SFI SPECIFICATION 1.2 EFFECTIVE: FEBRUARY 9, 2006* PRODUCT: Multiple Disc Clutch Assemblies for Vehicles with Naturally Aspirated Engines

Test Report Project Nr. 2013/020

TABLE OF CONTENTS. 8.3 Online Sensor Specifications. Series TS (Models TS1, TSP, TSH, TSL,TSF, TSB1, TSB2) According to Electromatic factory procedure

Transcription:

Report No. :DH1509300024A Version:A THERMAL SHOCK TEST REPORT Company :FLIP CHIP OPTO. INC. Address :No.185, Kewang Rd., Longtan Dist., Taoyuan City 325, Taiwan (R.O.C.) Model Name :Apollo 600-B Lot Number :No.1, No.2, No.3 Date Received :OCT 01, 2015 Date Tested :NOV 24, 2015 TESTING LABORATORY IS ACCREDITED BY: ISO 17025 accredited in respect of laboratory is approved by TAF Certificate No.:L3146-151112 ISTA certified laboratory (ID: ST-9389) WE HEREBY CERTIFY THAT: The test(s) shown in the attachment were conducted according to the indicating procedures. We assume full responsibility for the accuracy and completeness of these tests and vouch for the qualifications of all personnel performing them. Name Signature Date Test Engineer Nancy Chang Dec 01, 2015 Manager General Lee Dec 01, 2015 NOTE: 1. This report will be invalid if reproduced in part or altered in any way. 2. This report refers only to the specimen(s) submitted to test, and is invalid if used otherwise. 3. This report is ONLY valid with the examination seal and signature of this institute. 4. The tested specimen(s) will only be preserved for thirty days from the date issued, if not collected by the applicant.

Reliability Engineering Group Page 1 of 10 TABLE OF CONTENTS 1. GENERAL INFORMATION 1.1 DESCRIPTION OF UNIT... 2 2. THERMAL SHOCK TEST 2.1 TEST EQUIPMENT... 3 2.2 LABORATORY AMBIENCE CONDITION... 3 2.3 REFERENCE DOCUMENT... 3 2.4 TEST CONDITION... 3 2.5 SUMMARY OF TEST... 3 ATTACHMENTS... 4

Reliability Engineering Group Page 2 of 10 1. GENERAL INFORMATION 1.1 DESCRIPTION OF UNIT Manufacturer:FLIP CHIP OPTO. INC. Model name: Apollo 600-B Lot number:no.1, No.2, No.3 Sample quantity:each lot 1 piece, total of 3 pieces

Reliability Engineering Group Page 3 of 10 2. TEMPERATURE CYCLING TEST 2.1 TEST EQUIPMENT Model Serial Number Calibration Date ESPEC TPC-222M 290215 APR14, 2015 2.2 LABORATORY AMBIENCE CONDITION Temperature:25 C ± 5 C Relative humidity:55 % ± 15 % (RH) 2.3 REFERENCE DOCUMENT The test is based on customer specification 2.4 TEST CONDITION Temperature range:-40 C to +125 C Duration of exposure:15 minutes exposure at each temperature extreme Transfer time:10 seconds Number of cycles:1000 cycles 2.5 SUMMARY OF TEST Visual inspection of sample surfaces showed no abnormity. Functional check is performed by customer.

Reliability Engineering Group Page 4 of 10 Attachment 1:Photo of setup Test equipment Setup

Reliability Engineering Group Page 5 of 10 Attachment 2:Photo of units before and after test No.1 0 cycle 100 cycles 200 cycles 300 cycles 400 cycles 500 cycles

Reliability Engineering Group Page 6 of 10 No.1 600 cycle 700 cycles 800 cycles 900 cycles 1000 cycles Blank

Reliability Engineering Group Page 7 of 10 No.2 0 cycle 100 cycles 200 cycles 300 cycles 400 cycles 500 cycles

Reliability Engineering Group Page 8 of 10 No.2 600 cycle 700 cycles 800 cycles 900 cycles 1000 cycles Blank

Reliability Engineering Group Page 9 of 10 No.3 0 cycle 100 cycles 200 cycles 300 cycles 400 cycles 500 cycles

Reliability Engineering Group Page 10 of 10 No.3 600 cycle 700 cycles 800 cycles 900 cycles 1000 cycles Blank << The Following Blank >>