Electrical safety and reliability: Selective coordination. Protect with selective coordination

Similar documents
Specification made simple for selective coordination in a compact size

Medium Voltage Fuses. Industry s most comprehensive medium voltage circuit protection

Electrical Safety and Reliability: Short-Circuit Current Rating (SCCR) Equipment SCCR made easy

HVAC and Refrigeration Circuit Protection Solutions. Compact and safe HVAC/R circuit protection

Now - Up To 400A Mains!

The easiest and fastest way to select and specify the right control circuit fuse

The easiest and fastest way to select and specify the right fuse

CUBEFuse. CUBEFuse catalog numbers (amps)

Industry s most comprehensive medium voltage circuit protection

Electric vehicle auxiliary fuses 500 Vdc, A

Bussmann series Quik-Spec Coordination Panelboard

Quik-Spec. Section Contents

BUSSMANN. CUBEFuse Compact Circuit Protector Base (CCPB) SERIES. Technical Data Effective April 2017 Supersedes April 2016

6.3 mm reverse quick connect

Compact Circuit Protector (CCP) Application Note

Quik-Spec Electrical Gear

Effective December 2015 Supersedes September 2013

Products for enhancing electrical safety and reliability

A case study in solving SCCR issues

Bolted contact switches. Pringle switches

BUSSMANN. Pre-production and sample electric vehicle power fuses 500 Vdc, A SERIES. Technical Data Effective December 2018.

Are the New 2005 NEC Selective Coordination Requirements Causing an Increase in Arc Flash Energies and Reducing Distribution System Reliability?

Leadership in Circuit Protection

Selective Coordination Requirements

Electrical Safety and Overcurrent Protection

This small footprint makes a BIG impact

BRANCH CIRCUIT PROTECTION FUSED COORDINATION PANELBOARD

Leadership in Circuit Protection

The driving force behind innovative products and accessories

Fused Coordination Panelboard

ABB life cycle services Uninterruptible power supplies

Powering business worldwide

Fusetron FRN-R Class RK5 250Vac/125Vdc A, dual element, time-delay fuses

Quik-Spec Coordination Panelboard

Bussmann series Quik-Spec Power Module Switch elevator disconnect

Medium voltage vacuum circuit breaker. E-VAC series

Compact Circuit Protector (CCP)

Compact Circuit Protector (CCP) 1-, 2- and 3-pole Class CC, Midget, 10x38mm

Low-Peak LPJ Class J 600Vac/300Vdc, 1-60A, dual element, time-delay fuses

Application note Compact Circuit Protector (CCP2) Smaller, better... the Power of Space

ECET Distribution System Protection. Overcurrent Protection

Advanced Guide To Understanding Assembly Short-Circuit Current Rating WITH ENGINEERING SOLUTIONS AND OVERCURRENT PROTECTION DEVICES TO ENHANCE SCCR

Evaluating Selective Coordination Between Current-Limiting Fuses And Non Current-Limiting Circuit Breakers

Number 1 in efficiency

Applying Interrupting Rating: Circuit Breakers

NEC REQUIREMENTS FOR GENERATORS

Applying Interrupting Rating: Circuit Breakers

Downtime Reduction, Workplace Safety & Code Compliance SERVICES TO INCREASE YOUR PRODUCTIVITY THROUGH PROTECTION

Fused Coordination Panelboard

Selection and application guide

Simplified Guide To Understanding Short-Circuit Current Rating FIND IT, FIX IT, FORGET IT

Understanding National Electric Code (NEC) tap rules How do they apply to circuit breaker terminals?

DER Commissioning Guidelines Community Scale PV Generation Interconnected Using Xcel Energy s Minnesota Section 10 Tariff Version 1.

Selection Guide Motor Control Device Solutions

Selective Coordination Enforcement:

SECTION LOW VOLTAGE DISTRIBUTION EQUIPMENT

Evaluating Selective Coordination Between

FRNR A 250V TD Class RK5 Dual Elem Fuse-Fusetron

Overview Brochure Integrated Power Distribution. Medium Voltage Assembly Solutions

Tradition. Technology. Innovation.

Electrical sector solutions E Line family. Industry leading design in a compact package

Fuseology. Fuse Holders, Fuse Blocks, Power Distribution Blocks & Surge Suppression. Optima Fuse Holders & Overcurrent Protection Modules.

Selective Coordination

Quik-Spec Coordination Panelboard Specifications

6/4/2017. Advances in technology to address safety. Thomas A. Domitrovich, P.E., LEED AP VP, Technical Sales Eaton

Eaton vacuum interruption (EVI) technology. Proven vacuum interruption technology Environmentally focused circuit protection for global innovation

Air Circuit Breaker Retrofitting

VCP-T/T-VAC medium voltage vacuum circuit breakers. Control and protect with Eaton s compact medium voltage circuit breakers

Harmonization of IEC and North American Safety Standards

A comparison of metal-enclosed load interrupter (ME) switchgear and metal-clad (MC) switchgear

Assembly not available for new installations.

Selective Coordination

Protectors. Manual motor. Types MS116, MS132, MS45x, MS49x. MS Series. Manual motor protectors. Type MS116. Type MS132. Type MS45x.

BorgWarner s growing hybrid and electric product portfolio delivers clean, efficient vehicle propulsion

Type BR thermal magnetic trip curve results

Up to 60 A Class R 250 V and 600 V ferrule power distribution fuse blocks

Equipment Product Overview

W-VACi MV circuit breakers

Ampgard The name motor applications rely on

Implementing Overtemperature and Overcurrent Protection Matching Today s Higher Current Capacity Lithium-Ion Batteries

Understanding Arc Flash Hazards. White Paper

Busway Construction. Bus Bars

ETAP Implementation of Mersen s Medium Voltage Controllable Fuse to Mitigate Arc Flash Incident Energy

Auxiliary Power Systems. Delivering the power as you need

contactless wafer handling with green light macro inspection

Compact Circuit Protector

Fuseology. Dual-Element, Time-Delay Fuse Operation

Fuseology. High Speed Fuses

LKN A 250V Super-Lag Fuse Link. Features amperage rating 200 class Voltage Rating 250. Long Description. Manufacturer Information

This is intended to provide uniform application of the codes by the plan check staff and to help the public apply the codes correctly.

ABB. Replacement Components

Microgrid solutions Delivering resilient power anywhere at any time

Suggestion on How to Use

Bussmann series NH catalogue. Leadership in circuit protection

FUSES. Safety through quality

MP-4000 Motor Protection

Selective Coordination Compliance Methods for Evaluation and Mitigation

PROTECTION OF THE BRANCH CIRCUIT

YOUR ELECTRICAL SYSTEM IS YOUR LIFELINE AMP-TRAP 2000 FUSES

Class R 250V and 600V modular ferrule and knifeblade fuse blocks

Transcription:

Electrical safety and reliability: Selective coordination Protect with selective coordination

Safe, reliable and cost-effective power distribution Commercial, healthcare and industrial facilities require reliable power distribution without compromising the safety of people or equipment, which is often driven by code requirements. We understand that this can be a difficult result to achieve. Eaton offers the broadest circuit protection and electrical safety solutions in the industry that enable customers to achieve code compliance more effectively and economically than our competitors. What s more, we offer technical expertise and a support structure to help achieve project goals, whether facing new construction, expansion or renovation. Our comprehensive portfolio of overcurrent and overvoltage circuit protection products offers solutions that not only enhance safety and reliability, but also help ensure compliance with code requirements. Additionally, many of our products boast compact sizes, helping to reduce the equipment footprint and drive down costs. Our team of application engineers and sales engineers can recommend solutions for reducing footprint and saving installation time, all while providing the industry s best protection. They can also guide you in the selection of products to help meet all of your project's requirements. Delivering the level of protection you need With safe and reliable power distribution top priority, selectivity has always been a key goal for power system designers. But determining the type of power distribution system that will meet code and project requirements can be a difficult process. Historically, the level of selectivity desired for a project was the choice of the system designer. However, the most recent edition of the National Electric Code (NEC), published in 2014, specifically defines selective coordination in Article 100. The 2014 NEC also provides minimum requirements for coordination in healthcare essential electrical systems, as outlined in Essential Electrical Systems for Hospitals Coordination 517.30. Coordination applies to circuit protection devices for any fault time extending beyond 0.1 seconds. These revisions from previous editions not only clarify the terms, but also set specific standards for system safety and reliability. Selective coordination applies for the full range of overcurrents on the system and the full range of overcurrent device interrupting times associated with those overcurrents. Selective coordination is required for systems related to life safety as defined by: Elevators 620.62 Critical Operations Data Systems 645.27 Multi-building Campus-Style Complexes (Fire Pumps) 695.3(C)(3) Emergency Systems 700.28 Legally Required Standby Systems 701.27 Critical Operations Power Systems (COPS) 708.54 Local and national code requirements, as well as customer preference for system characteristics, ultimately determine the level of coordination needed. Regardless of the level chosen, Eaton has the right products and solutions to solve them competitively. Visit www.eaton.com/selectivecoordination for more information on how Eaton can deliver the level of protection you need.

Understanding selective coordination and coordination Selective coordination is achieved when an overcurrent on a circuit is interrupted and only the closest upstream device opens such that only the section of the electrical system with a problem is taken offline. Selective coordination applies for the full range of overcurrents on the system and the full range of interrupting times associated with those overcurrents. Coordination is required for overcurrent protective devices for Essential Electrical Systems in healthcare facilities. The overcurrent protective devices must be coordinated for any fault duration extending beyond 0.1 seconds. Essential Electrical Systems are comprised of life safety branch, critical branch, and equipment branch. Portfolio spotlight: Solutions that exceed expectations Circuit Protection Finger-safe Bussmann series CUBEFuses TM reduce footprint up to 70% Bussmann series Low-Peak TM fuses offer superior current limitation to help increase short-circuit current ratings Eaton molded-case circuit breakers minimize downtime and offer advanced safety features 310+ Trip Unit enhances coordination, offering features such as an arc reduction maintenance switch Arc Flash Reduction Maintenance System Fastest arc flash energy reduction technology for personnel safety Remotely enabled for worker safety with remote indication for situational notification Code mandated in NEC Section 240.87 for Arc Energy Reduction for circuit breakers 1200A and above Available in molded case circuit breakers from 55A-2500A and air circuit breakers up to 6300A 24Vdc circuit allows for manual or interlock switch connection for simple activation Quik-Spec TM Coordination Panels Ease of selective coordination using published circuit breaker/ fuse and fuse/fuse ratio tables Compact footprint up to 40% smaller than other fusible solutions Safety-focused design that includes finger-safe branches, branch fuse interlock and fuse ampacity rejection

Normal source Emergency source The diagram above shows three options for an emergency system (fully fused, all circuit breakers or fuse and circuit breaker hybrid). These same options are available for other critical loads such as legally required standby systems or critical operations power systems.

Leadership in circuit protection When it comes to circuit protection, only Eaton can provide a complete portfolio of solutions for virtually every application. Eaton delivers: The most diverse solutions to mitigate arc flash energy for personnel and equipment protection. The smallest and most cost effective solutions to meet selective coordination requirements. The most experienced, time-tested solutions to meet national and local code requirements. The most tested circuit breaker/circuit breaker, circuit breaker/fuse, and fuse/fuse selective coordination combinations. The only one-stop shop to solve your design challenges using our expertise and an unmatched portfolio. Our focus is on delivering the right solution for the application. But, decision makers demand more than just innovative products. They turn to Eaton for an unwavering commitment to personal support that makes customer success a top priority. At Eaton, that s how we re powering business worldwide. Case study A U.S. customer for a municipal building project needed to achieve selective coordination in order to comply with NEC requirements, and wanted to do so in a cost-effective manner. Because Eaton has more than 100 years of experience with power distribution applications and a deep understanding of the NEC, the customer reached out to a local Eaton application engineer for support in efficiently designing the building s power distribution system. Additionally, our team was able to offer a portfolio of both component and assembly products, as well as the support to ensure the project was designed, installed and commissioned quickly and cost efficiently. After working closely with our team, the customer now has a power distribution system that utilizes both Eaton circuit breakers and Bussmann series fuses (a hybrid system), that achieves selective coordination and provides safer and more reliable power.

Eaton 1000 Eaton Boulevard Cleveland, OH 44122 United States Eaton.com Electrical Sector 1000 Cherrington Pkwy Moon Township, PA 15108 United States Eaton.com/electrical Bussmann Division 114 Old State Road Ellisville, MO 63021 United States Eaton.com/bussmannseries 2015 Eaton All Rights Reserved Printed in USA Publication No. 10382 May 2015 Want to learn more? Visit us at: Eaton.com/selectivecoordination