R-MAG. Vacuum Circuit Breaker with Magnetic Actuator Mechanism

Similar documents
R-MAG Vacuum Circuit Breaker with Magnetic Actuator Mechanism 15.5 kv - 27 kv; 1200 A A

Descriptive Bulletin. R-MAG TM magnetically actuated dead tank outdoor vacuum circuit breaker 15.5 kv - 38 kv

Descriptive Bulletin. R-MAG magnetically actuated dead tank outdoor vacuum circuit breaker 15.5 kv - 38 kv

AMVAC TM technical guide Vacuum circuit breaker with magnetic actuator mechanism

SafeGear Motor Control Center Arc Resistant Metal-Clad Construction Brochure

Type SDV6 distribution circuit breaker. Top performance - proven reliability. Answers for energy.

16kA Solid Dielectric, Triple Option Reclosers Catalog VLT12

Horizontal Circuit Switchers

Air-insulated switchgear UniGear type ZS1

Solid Dielectric, Triple Option Reclosers Catalog O-vlt14

Solid Dielectric, Triple Option Reclosers Catalog O-vlt14

Horizontal Circuit Switchers

Using new Magnetically Actuated Vacuum Interrupter technology for safe and reliable medium voltage circuit breaker switching in mines

Solid Dielectric, Single Phase Recloser

SUBSTATION VACUUM CIRCUIT BREAKER (38KV)

SUBSTATION VACUUM CIRCUIT BREAKER (25.8 / 27KV)

SafeGear TM Motor Control Center Arc resistant metal-clad construction

SUBSTATION VACUUM CIRCUIT BREAKER (15.5KV)

Type SDV7 distribution circuit breaker family

OVR Three Phase Recloser 15 kv - 38 kv. Descriptive Bulletin

R-MAG Medium Voltage Outdoor Dead Tank Vacuum Magnetic Circuit Breaker

VersaRupter 5-38 kv Load Interrupter Switch. Technical Guide

SDV7. Outdoor distribution circuit breaker family 15.5 kv to 38.0 kv. usa.siemens.com/sdv7

Dead Tank Circuit Breaker 145PM40-C Compact design with enhanced reliability

Characteristics of LV circuit breakers Releases, tripping curves, and limitation

Solid Dielectric, Single Phase Reclosers

Descriptive bulletin. Medium voltage load interrupter switchgear Reliable, low maintenance and economical for distribution applications

AutoLink Frequently Asked Questions

Outdoor live tank vacuum circuit breaker Type OVB-VBF for 24/36/40.5 kv applications

Cobra-S. Catalog Cobra-S

Molded Vacuum Reclosers The recloser you want, all in one package. Single- and Three-Phase Molded Vacuum Reclosers, 15 38kV

GROUP D. Switch & Protective device.

SIEMENS. Series 8100oT Vacuum Controllers. www. ElectricalPartManuals. com. Bulletin CC

Advance 27 ANSI 27 kv switchgear

Outdoor vacuum breaker for railway applications - FSK II

Product Group Brochure. PS Range Capacitor Vacuum Switches

Medium Voltage Outdoor Apparatus Portfolio 2009

1VAL2401-SG Rev D. Spare parts list for Outdoor Products Reclosers, breakers, & padmount switches

EE 741 Over-voltage and Overcurrent. Spring 2014

Descriptive bulletin. ReliaGear ND ANSI narrow frame metal-clad switchgear

Outdoor Padmount Switching Products

Contactor V-Contact VSC/P

Type SDV7 distribution circuit breaker family Answers for energy.

SWITCHGEAR DIVISION PRODUCT PROFILES

SafeGear TM Motor Control Center Arc resistant metal-clad construction Motor Control Center Descriptive bulletin

Product Specification Guide. Title: Southern States 72 kv RLSwitcher Vertical Interrupter Style Reactor Switcher

MAHALAKSHMI ENGINEERING COLLEGE TIRUCHIRAPALLI

B4 Load Break Switches

Padmount Solid Dielectric Switchgear Catalog

Outdoor live tank SF6 circuit breaker EDT with integrated current transformer up to 72.5 kv

Product Specification Guide. Title: Southern States 362 kv RLSwitcher Vertical Interrupter Style Reactor Switcher

ISO Rules Part 500 Facilities Division 502 Technical Requirements Section Interconnected Electric System Protection Requirements

VOLUME: IIIC SCHEDULE IIIC/4 11 KV AND 3.3 KV SWITCHGEARS

Solid Dielectric, Three Phase Reclosers CATALOG VS11

Data Bulletin. Ground-Censor Ground-Fault Protection System Type GC Class 931

C1000 Series Automatic Cap Bank

VCP-T/T-VAC medium voltage vacuum circuit breakers. Control and protect with Eaton s compact medium voltage circuit breakers

Publication No.: PSG

FEBRUARY 14, 2017 Joslyn Hi-Voltage Capacitor switches customer presentation

DISTRIBUTION SOLUTIONS. GSec Gas-insulated switching and isolating apparatus

CP Automatic capacitor bank

Power & High Voltage Joslyn Hi-Voltage Overhead Reclosers & Switches H-220. Series HVI Hi-Velocity Interrupter Attachment

The University of New South Wales. School of Electrical Engineering and Telecommunications. Industrial and Commercial Power Systems Topic 6

Medium Voltage Equipment 5-15 kv GM-SG and 38 kv GM38 Metal-Clad Switchgear General

DPX earth leakage DPX 3 -I earth leakage

CITY OF LOMPOC UTILITIES DEPARTMENT ELECTRICAL DIVISION SPECIFICATION NO. ELE-112 SUBSTATION CLASS VACUUM CIRCUIT BREAKERS OCTOBER 2008

Longest Life Product for Electric Furnace Applications! 100,000 Operations No Routine Maintenance Required!

3TM Vacuum Contactors

A Summary of Major Improvements to the ABB Recloser and Type R Breaker

Transmission Switching

Specification for 70mm pole pitch Air circuit breaker up to 1600 A

Essential equipment for all your requirements

Programmable Logic Controller. Mat Nor Mohamad

AN ASYMMETRICAL MAGNETIC ACTUATOR FOR M.V. CIRCUIT-BREAKERS

MULTI 9 System Catalog IEC Rated C60N/H/L Circuit Breakers

Advance design OEM L-Frames, cell kits, & enclosures Metal-clad switchgear components OEM catalog & pricing

solutions RUS accepted

SION Vacuum Circuit-Breakers. Answers for energy. Medium-Voltage Equipment Selection and Ordering Data. Catalog HG

SafeGear Motor Control Center Arc Resistant Metal-Clad Construction Descriptive Bulletin

Q pole Pole Mounted Capacitor System

CPG.0 Single busbar gas-insulated cubicles

5kV to 38kV, 630 Amp to 4000 Amp Indoor or Outdoor Application

Type CDG 14 Extremely Inverse Time Overcurrent and Earth Fault Relay

Underground Distribution Switchgear

SION Vacuum Circuit-Breakers. Answers for energy. Medium-Voltage Equipment Selection and Ordering Data. Catalog HG

Specification Guide. for RMVAC. Direct Replacement. AC Medium Voltage. Circuit Breakers

Transformer bushings, type GOH. Technical guide

Solid Dielectric, Triple Option Reclosers Catalog O-vst14

ABB Components. Switchgear, Distribution Breakers and Reclosers

Solid Dielectric, Independent Pole Operated Reclosers Catalog O-vst16

Bolted contact switches. Pringle switches

DPX moulded case circuit breakers

Indoor or Outdoor 2400 to 14,400 Volts 600 to 14,400 Kvac, 3 Phase, 60 Hz

Medium Voltage Standby non-paralleling Control GUIDE FORM SPECIFICATION

SF6 Load Break Switch 2017 FIL3 - S. Indoor Medium Voltage LBS With or without fuse 12kV- 24kV FIL3 D FIL3. 24KV SF6 Load Break Switch

LG HRC Power Fuses ISO 9001 ISO 14001

MV Air Insulated Switchgear TAP17. Technical Data TGOOD

Ensuring excellent switching capability and high quality with various advantages

Medium Voltage Metal-Enclosed Switches

EMPAC Metal enclosed capacitor bank for wind applications

Transcription:

R-MAG Vacuum Circuit Breaker with Magnetic Actuator Mechanism

R-MAG Features: Low maintenance 10,000 mechanical operations (five times ANSI requirements) Simple magnetic actuator Vacuum interruption Definite purpose capacitor switching in accordance with ANSI C37.06 Environmentally friendly with no gas or oil interrupting media No derating of interrupting capability regardless of reclosing cycle Reactor switching R-MAG circuit breakers have been fully tested to the most recent versions of ANSI C37.04, C37.06, C37.09 and IEC 62271. Available for 15 and 27 kv applications, this next generation circuit breaker offers solutions for many applications. 2 ABB

R-MAG. The circuit breaker. Breaker Evolution - Matching optimum technologies 27 kv 15 kv Although many refinements have been made throughout the 80 year history of the outdoor circuit breaker, there have only been three generations of circuit breaker design. Early circuit breaker mechanisms were spring charged with separate close and trip springs used for oil breakers. The second generation of breakers used this same mechanism, modified for vacuum interruption. The new R-MAG generation of circuit breakers uses a magnetic actuator mechanism with vacuum interrupters. Each generation reflects the best technology available at the time of their introduction, building on the strengths of previous designs, while adding new innovations. Although it is well established that vacuum interrupters are capable of more than 10,000 operations, conventional stored energy mechanisms seldom operate beyond 500 operations without maintenance, re-lubrication, or replacement of parts. The main disadvantage of stored energy mechanisms is the large number of precision moving parts required to perform spring charging, closing and tripping functions. Conventional stored energy breakers also place limitations on the types of control voltages allowed. The R-MAG is truly the next generation in medium voltage vacuum circuit breaker technology. ABB is the first to combine the unique requirements of vacuum interrupter technology with a magnetic actuator designed to exploit these capabilities. Using a flux-shifting device with integral permanent magnets, the R-MAG mechanism has only one moving part. With simple open and close coils, an electronic controller and capacitors for energy storage, the R-MAG circuit breaker mechanism is capable of 10,000 operations. These are merely a few of the features that mark a departure from the conventional spring operated mechanism, introducing new capabilities and benefits for modern power systems. ABB 3

R-MAG Summary of benefits: Simple mechanical operation Actuator has only one moving part Manual opening capability High reliability The magnetic actuator, electronic controller and capacitors are the key components for this next generation product. The magnetic actuator has a magnetic frame assembly, two identical operating coils, two rare earth magnets and a single moving armature. Instead of mechanical assemblies for armature position sensing, proximity sensors detect armature position for the electronic controller. These permanent magnets will retain 99% of their flux density for more than 100 years. Extended life capacitors, used as stored energy devices, drive the actuator, minimizing the inrush current from the source. These special capacitors charge in as little as seven seconds after control power is available, and are "trickle charged" by the electronic controller as needed. Covers over the capacitor terminals prevent accidental contact. The magnetic actuator and control components are mounted in the low voltage compartment. All components at line potential are contained in the high voltage section and are completely isolated from the control compartment. Insulating entrance bushings are attached to the roof assembly by bolt and compression type clamps. Removal or replacement does not disturb the existing breaker adjustments. Bushing current transformers mount on the entrance and/or exit bushings. The accuracy class required determines the number of current transformers that may be mounted. All Type R-MAG circuit breakers use flexible shunt connectors. The R-MAG circuit breaker is designed to provide many years of trouble free service for the end user. 4 ABB

R-MAG. Circuit-breaker of the high tech generation. Construction of a vacuum interrupter Stem Twist protection Metal bellows End cap Bellows shield Ceramic insulator Vacuum Interrupter The conduction and interruption of short-circuit currents places great demands on vacuum interrupters. The robust construction of the ABB vacuum interrupters ensures fault-free and maintenance-free operation for decades. Control Wiring Auxiliary control relays and the electronic control module are mounted on panels located in the low voltage compartment. Fused switches protect control circuits. All bushing current transformer connections are wired to shorting type terminal blocks in the low voltage compartment. Main shield Contacts Stem End plate 30,000 operations at load current Electronic Controller The electronic controller uses robust components and a conformal coating to prolong the life of the device. The electronic controller will operate on AC or DC control power because it internally utilizes an AC to DC converter. Instead of selecting from a long list of control power options, the user only needs to select a controller for the low voltage range control power (20.4-52.8 VAC or 16.8-75 VDC) or a controller for the high voltage range control power (85-264 VAC or 77-280 VDC). Inside these ranges, the user may apply any value of direct current, or any value of 50 or 60 cycle alternating current to achieve circuit breaker operation. The electronic controller incorporates all capacitor charging, open/close coil switching, anti-pumping, interlocking and armature position details. Programmed self-monitoring functions monitor proximity sensors, coil continuity, capacitor voltage and other key functions. Surge Withstand and Electromagnetic Capability tests have been successfully performed per IEC 61000 standards. Only six watts of energy are needed to maintain controller functions and capacitor full charge. There is an optional 33 watt setting that extends the charging time, which is suitable for smaller batteries or power sources. For normal operation, the minimum requirement of the auxiliary power supply is 93 watts. Contact ABB for details. Life curve of 25 ka vacuum interrupters ABB 5

R-MAG. Low maintenance permanent magnet technology. Instantaneous representation of magnetic flux density distribution Following the advance of vacuum interruption in the field of medium voltage circuit breakers in the last 20 years, a natural amalgamation of technology has been achieved with the addition of magnetic actuator technology. The requirements of one technology optimally match the opportunities of the other. Magnetic actuator technology naturally provides the suitable travel-time and force-travel characteristics for the vacuum switching devices. All operating mechanism functions are integrated in the magnetic actuator of the R-MAG circuit breaker. The actuator is a bistable magnet system, in which armature change-of-state is accomplished by the magnetic field of two electrically excited coils. The armature is held magnetically in the limit positions by the fields of two rare-earth permanent magnets. Switching operations are achieved by excitation of one of the two coils until the retaining force of the permanent magnets is exceeded. Even after complete failure of the auxiliary power, the energy stored in the capacitors will allow electrical operation for 200 seconds. In the event of complete loss of control power, the circuit breaker can be tripped manually. The armature of the magnetic actuator is linked to an operating shaft connected via insulated push rods to each of the vacuum interrupters. The only points of lubrication for this mechanism are at the union of the armature to the operating shaft, the pivot points of the operating shaft and the pivot points of the operating shaft to the push rods. Long life synthetic lubricants are applied during assembly to further reduce the need for lubrication during the life of the circuit breaker. Magnetic latching in a limit position Magnetic latching plus current build up in one coil Armature reaching the opposite limit position 6 ABB

R-MAG. Technical data. Voltage Class (kv) 15 kv 15kV 15 kv 15 kv 27 kv 27 kv 27 kv Continuous Current A 600/800/1200 600/800/1200 600/800/1200/2000 600/800/1200/2000/3000 1200 1200/2000 1200/2000 Rated Maximum Voltage (kv) 15.5 15.5 15.5 15.5 27 27 27 Voltage Range Factor K*** 1 1 1 1 1 1 1 Frequency (Hz) 50/60 50/60 50/60 50/60 50/60 50/60 50/60 Low Frequency Withstand Dry 60 Hz for 1 Min 50 50 50 50 60 60 60 Wet 60 Hz for 10 Sec 45 45 45 45 50 50 50 Full Wave Withstand (BIL) 110 110 110 110 125/150 125/150 125/150 Chopped Wave Withstand (kv peak) 142 142 142 142 194**** 194**** 194**** Operating Duty (Standard Duty Cycle) Exceeds ANSI standard, will meet O-0.3 sec-co-15 sec-co Interrupting Time (Cycles) 3 3 3 3 3 3 3 Permissible Tripping Delay Y (Sec) 2 2 2 2 2 2 2 Closing Time (Cycles) 6 6 6 6 6 6 6 Reclosing Time (Sec) 0.3 0.3 0.3 0.3 0.3 0.3 0.3 Short Circuit Interrupting Current (at Contact Part) ka, RMS, Sym 12.5 16 20 25 12.5 20 25 Close & Latch (Initial Current Loop) ka, RMS, Asym 20 25.6 32 40 20 32 40 Close & Latch (ka Peak) 32.5 41.6 52 65 32.5 52 65 Short Time Current (3 Sec) ka, RMS, Sym 12.5 16 20 25 12.5 20 25 Transient Recovery Voltage (kv Peak) 29 29 29 29 51 51 51 Load Current Switching Capability (A) 600/800/1200 600/800/1200 600/800/1200/2000 600/800/1200/2000/3000 1200 1200/2000 1200/2000 Wire Line Charging Current 100 100 100 100 100 100 100 Isolated Cable Charging Current (A) 600 600 600 600 400 400 400 Isolated Capacitor Bank Switching Current (A RMS) 600 600 600 600 400 400 400 Back-to-Back Shunt Capacitor Bank Switching Current (A RMS) Transient Overvoltage Factor Transient Inrush Current (ka Peak) Back-to-Back Transient Inrush Frequency (Hz) Back-to-Back Grounding of System and Capacitor Bank System Capacitor Bank Mechanical Life (No Load Operations)*** 600 600 600 600 400 400 400 3.0* 3.0* 3.0* 3.0* 3.0* 3.0* 3.0* 2.5** 2.5** 2.5** 2.5** 2.5** 2.5** 2.5** 20 20 20 20 20 20 20 4240 4240 4240 4240 4240 4240 4240 Grounded or Ungrounded Grounded or Ungrounded 10000 10000 10000 10000 10000 10000 10000 * General purpose ** Definite purpose *** Interrupter life good for 30,000 operations when interrupting loads are less than 1 ka. For interrupting loads greater than 1 ka, consult interrupter life curves on page 5. **** For 150 kv BIL full-wave rating only ABB 7

ABB Inc. 655 Century Point Lake Mary, FL 32746 U.S.A. For sales & marketing contact your local representative or: Tel: +1-407-732-2000 1-800-929-7947 Fax: +1-407-732-2029 www.abb.com/mediumvoltage 1VAL255101-DB July 2005 Rev G (replaces DB38-921M)